Lucent Technologies PacketStar PSAX 24N64 DS1/E1/DS0A CES Module User Guide
Publicité
Publicité
PacketStar
®
PSAX
12-Port Medium-Density DS1/E1/DS0A CES
Module
User Guide (E1 Mode)
Model 24N64 for the PacketStar
®
PSAX Multiservice Media Gateways
Issue 1, December 2004
System Software Release 10.0.0
Doc. No.: 255-700-576
Copyright © 2004 by Lucent Technologies. All rights reserved.
For trademark, regulatory compliance, and related legal information, see the "Legal Notices, Safety, and Regulatory Information" section.
Legal Notices, Safety, and Regulatory
Information
Copyright
Copyright © 2004 by Lucent Technologies. All rights reserved.
This material is protected by the copyright laws of the United States and other countries. It may not be reproduced, distributed, or altered in any fashion by any entity (either internal or external to Lucent Technologies), except in accordance with applicable agreements, contracts or licensing, without the express written consent of the originating organization and the business management owner of the material.
Trademarks
PacketStar , Lucent, Lucent Technologies, and the Lucent Technologies logo are registered trademarks of Lucent Technologies in the USA. Other product and brand names mentioned in this guide are trademarks or registered trademarks of their respective owners.
Notice
The information in this document is for informational use only, is subject to change without notice, and should not be construed as a commitment by
Lucent Technologies, Inc. This document is without warranty of any kind, either expressed or implied. Lucent Technologies, Inc. assumes no responsibility for any errors, inaccuracies, or omissions. Neither is any liability assumed for damages resulting from the use of the information or instructions contained herein. Lucent Technologies, Inc. is not responsible for any damage or loss to your data or equipment resulting either directly or indirectly from use of this document.
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
255-700-576
Release 10.0.0
iii
Warranty Information
Software and Hardware Limited Warranties
Lucent Technologies provides a 90-day limited software warranty, and a oneyear limited hardware warranty on this product. Refer to the Software License
and Limited Warranty Agreement and the Lucent Technologies InterNetworking Sys-
tems Global Warranty that accompanied your package for more information.
Warranty Warnings
!
WARNING:
When inserting modules into the chassis, slide them gently, not forcefully. Excessive force may cause the modules to be seated improperly in the chassis, and result in possible damage to the module or the chassis.
Install or remove modules one at a time. Doing this aids in preventing the PSAX system from indicating any erroneous failure messages, and allows the PSAX system time to reinitialize and display the accurate configuration of the module that is inserted.
!
CAUTION:
Modifying or tampering with PSAX chassis components may void your warranty. Any modification to this equipment not expressly authorized by Lucent Technologies may void your granted authority to operate such equipment.
!
CAUTION:
Shipping the chassis with removable I/O, server, or CPU modules installed may cause damage to the chassis and the modules. Damage to any of the components in the system resulting from shipping the chassis with removable modules installed will void your warranty.
Safety Warnings and Information
When installing and operating the 12-Port Medium-Density DS1/E1/DS0A
CES module, follow the safety guidelines provided in the PacketStar
®
PSAX
Multiservice Media Gateway Safety Guidelines, which accompanies this product, to help prevent serious personal injury and damage to the module. Please read all warnings and instructions supplied before beginning installation or configuration of this module. In addition to the general safety information provided, you should also refer to the appropriate PSAX installation guide for other important safety information and procedures.
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1 iv
Release 10.0.0
255-700-576
Regulatory Standards Compliance
Safety and Electromagnetic Compatibility (EMC)
The following PacketStar PSAX systems are compliant with applicable safety and EMC standards when configured with the 12-Port Medium-Density
DS1/E1/DS0A CES module (model 24N64):
• PSAX 1000 system
• PSAX 1250 system
• PSAX 2300 system
• PSAX 4500 system
Refer to the PacketStar PSAX 1000, PSAX 1250, PSAX 2300, or PSAX 4500 installation guide for details on safety and EMC standards compliance.
Telecommunications
The 12-Port Medium-Density DS1/E1/DS0A CES module (model 24N64) is compliant with the following applicable telecommunications standards:
• FCC Part 68 (USA)
• CS-03 Issue 8 (Canada)
Regulatory Statements
USA Regulatory Statements
FCC Part 68
This equipment complies with Part 68 of the FCC rules. On the back of the
PSAX chassis is a label that contains the FCC registration number, in addition to other information. You must provide this information to the telephone company, if they request it. The FCC requires Lucent Technologies to provide you with the following information:
1. This equipment has digital service interface capabilities using RJ-48C and RJ-48H connectors. The facility interface codes with which this equipment complies for digital services are as follows: 04DU9-BN,
04DU9-DN, 04DU9-1KN, and 04DU9-1SN. This equipment has loop start interface capabilities using an RJ-11C connector. The facility interface code with which this equipment complies for service is 02LS2. The service order codes for this equipment are 6.0F for the T1 interface and
9.0Y for the loop start interface.
2. An FCC-compliant telephone network interface jack is built into this equipment and is compatible with interconnections that are Part 68 compliant.
3. The REN for the 4-Port Voice 2-Wire Office module when used in this equipment is 0.7B.
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
255-700-576
Release 10.0.0
v
4. If this equipment causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service might be required. But if advance notice is not practical, the telephone company will notify you as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe this is necessary.
5. The telephone company might make changes in its facilities, equipment, operations, or procedures that could affect the operation of this equipment. If this happens, the telephone company will provide advance notice for you to make necessary modifications to maintain uninterrupted service.
6. If you experience trouble with this equipment, or need repairs or warranty information, please refer to the Lucent Technologies InterNetworking
Systems Global Warranty that accompanied your PSAX product shipment for instructions on obtaining technical support in your area.
If this equipment is causing harm to the telephone network, the telephone company might request that you disconnect the equipment until the problem is resolved.
7. This equipment has no user-serviceable parts.
This equipment cannot be used on public coin telephone service provided by the telephone company. Connection to party line service is subject to state tariffs. Contact your state public utility commission, public service commission, or corporation commission for information.
Canadian Regulatory Statements
CS-03 Issue 8
NOTICE: This equipment meets applicable Industry Canada Terminal Equipment Technical Specifications. This is confirmed by the registration number. The abbreviation, IC, before the registration number signifies that registration was performed based on a Declaration of Conformity indicating that Industry Canada technical specifications were met. It does not imply that Industry Canada approved the equipment.
The Ringer Equivalence Number (REN) assigned to the 4-Port Voice 2-Wire
Office module denotes the percentage of the total load to be connected to a telephone loop, which is used by the device, to prevent overloading. The termination on a loop may consist of any combination of devices subject only to the requirement that the total of the REN of all devices does not exceed 5.
The REN for the 4-Port Voice 2-Wire Office module when used in the PSAX system is 0.7B.
SH-03 Version 8
AVIS: Le présent matériel est conforme aux spécifications techniques d’Industrie Canada applicables au matériel terminal. Cette conformité est confirmée par le numéro d’enregistrement. Le sigle, IC, placé devant le numéro d’enregistrement, signifie que l’enregistrement s’est effectué conformément à une déclaration de conformité
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1 vi
Release 10.0.0
255-700-576
et indique que les spécifications techniques d’Industrie Canada ont
été respectées. Il n’implique pas qu’Industrie Canada a approuvé le matériel.
Le nombre équivalent de sonnerie (REN) attribué au module central bifilaire
(Voice 2-Wire Office) correspond au pourcentage de la charge totale à connecter à un circuit téléphonique bifilaire; il est utilisé par l’appareil pour prévenir la surcharge. Le circuit peut être terminé par n’importe quelle combinaison d’appareils, à la seule condition que le total des REN de ces derniers ne dépasse pas cinq.
Lorsqu’il est utilisé dans le système PSAX, le module central bifilaire possède un REN de 0,7 B.
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
255-700-576
Release 10.0.0
vii
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1 viii
Release 10.0.0
255-700-576
Table of Contents
Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
255-700-576
Release 10.0.0
ix
Table of Contents
Module Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Configuring Ports and Channels Using the Console . . . . . . . . . . . . . . . . . . . 3-1
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1 x
Release 10.0.0
255-700-576
Table of Contents
Pin Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
Reference Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
255-700-576
Release 10.0.0
xi
List of Figures
12-Port Medium-Density DS1/E1/DS0A CES Modules Connected to 24-port RJ Patch Panel
12-Port Medium-Density DS1/E1/DS0A CES Modules Connected to 24-port RJ Patch Panel
12-Port Medium-Density DS1/E1/DS0A CES Modules Connected to 48-port RJ Patch Panel
12-Port Medium-Density DS1/E1/DS0A CES Modules Connected to 48-port RJ Patch Panel
Sample Equipment Configuration Window on a PSAX 1000
Sample Equipment Configuration Window on a PSAX 1250
Sample Equipment Configuration Window on a PSAX 2300 or
Sample Equipment Configuration Window on a PSAX 1000, PSAX 2300, or
Sample Equipment Configuration Window on a PSAX 1250
Equipment Configuration Window (As Displayed on the PSAX 1250, PSAX 2300, and
Equipment Configuration Window (As Displayed on the PSAX 1250, PSAX 2300, and PSAX 4500
3-10 12-Port Medium-Density E1 Port and Channel Configuration Window
3-11 12-Port Medium-Density E1 Channel Configuration Window (One Channel per Port) . . . . . .3-22
3-12 12-Port Medium-Density E1 Port and Channel Configuration Window
3-13 Medium Density 12-Port E1 Channel Configuration Window (Several Channels per Port) . . .3-27
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
255-700-576
Release 10.0.0
xii
List of Tables
3-4 12-Port Medium-Density E1 Port and Channel Configuration Window
3-10 12-Port Medium-Density E1 DS0s Strap Display Window Field Descriptions . . . . . . . . . . . . . 3-29
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
255-700-576
Release 10.0.0
xiii
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1 xiv
Release 10.0.0
255-700-576
1
Getting Started
Purpose of This Guide
The PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User
Guide (E1 Mode) provides a description of the 12-Port Medium-Density
DS1/E1/DS0A CES module. It also provides information on how to configure the module ports and channels.
For information on configuring interfaces and provisioning connections through the PSAX console interface, see the PacketStar
®
PSAX Connections Pro-
visioning Guide. If the Navis
Navis
®
®
EMS-PSAX interface is being used, see the
EMS-PSAX Interface and Connection Provisioning Guide.
Note:
If you are using this module for the first time, you should read through this guide in its entirety before beginning the configuration process. The chapters in this guide are arranged in the logical order of normal configuration and should be performed in that order for the module to operate successfully.
Audience for This Guide
The information in this guide is intended for users who will configure ports and channels for the 12-Port Medium-Density DS1/E1/DS0A CES module in the E1 mode, configure the interface types, and provision connections for the
PSAX Multiservice Media Gateway system using the console interface. To configure ports and channels for the 12-Port Medium-Density DS1/E1/DS0A
CES module in the DS1 mode, see the PacketStar
®
PSAX 12-Port Medium-Den-
sity DS1/E1/DS0A CES Module User Guide (DS1 Mode), 255-700-592. To configure ports and channels for the 12-Port Medium-Density DS1/E1/DS0A CES module in the DS0A mode, see the PacketStar
®
PSAX 12-Port Medium-Density
DS1/E1/DS0A CES Module User Guide (DS0A Mode), 255-700-569.
What You Should Know
Before you use this document or operate a PSAX system, you should already understand and have experience with the following:
• Ethernet network capabilities
• Internet Protocol capabilities
• Data network design
• Telephony network design
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
255-700-576
Release 10.0.0
1-1
Chapter 1 Getting Started
Related Reading
Related Reading
Lucent Technologies Information Products
Product Information
Library
To install, operate, and configure your PSAX system and I/O and server modules, read the PSAX publications provided on your Lucent Technologies
PacketStar
®
PSAX Multiservice Media Gateways Product Information Library
CD-ROM.
Printed Documents
For your convenience, many of the documents included on the PacketStar
®
PSAX Multiservice Media Gateways Product Information Library CD-ROM are also available in printed form. You can order these documents through the Lucent
Technologies Customer Information Center Web site at:
http://www.lucentdocs.com.
Other Publications
Numerous books are currently available on the subject of basic telecommunications technology and specific protocols. In addition to such general reading, you should also be familiar with the industry specifications identified in this guide.
About Lucent Technologies
Lucent Technologies is the communications systems and technology company formed through the restructuring of AT&T. We bring with us a tradition of more than 125 years of experience and a dedication to superior customer service.
Lucent Technologies manufactures, sells, and services a complete line of customer premises communications units, and commercial and multimedia communications and messaging systems designed and supported by our research and development unit, Bell Laboratories.
Our legacy and our spirit of innovation allow Lucent to provide our customers with the tools needed to communicate effectively, any time and anywhere, and to integrate the latest technologies into real-life solutions that help make business work.
For More Information
To learn more about the PacketStar PSAX family of Multiservice Media Gateways and the complete line of Lucent Technologies products, visit our Web site at http://www.lucent.com.
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
1-2
Release 10.0.0
255-700-576
Chapter 1 Getting Started
About the PacketStar® PSAX Product Family
About the PacketStar
®
PSAX Product Family
Lucent Technologies provides a complete range of PSAX Multiservice Media
Gateways in the PacketStar PSAX family.
PSAX 1000 Multiservice Media Gateway
P
The PacketStar PSAX 1000 Multiservice Media Gateway is designed to provide a full range of central office-based multiservice media gateway functions in a small, competitively-priced package suitable for customer premise deployment. Ideal for central office, large enterprise, or wireless cell site multiservice media gateway applications, the PSAX 1000 system provides highly reliable network access for time-division multiplex voice, frame relay,
10/100BASE-T Ethernet, and ATM data applications.
When it is functioning in a redundant operating mode and after it has experienced a single-point failure, the PSAX 1000 system provides up to 630 Mbps of ATM cell bus capacity. The total ATM cell bus capacity of the system may also be scaled to provide nonblocking, nonredundant chassis bandwidths beyond 630 Mbps.
Supporting up to five slots (19–inch chassis) for I/O and server modules—with a full range of interfaces such as DS0A, DS1/E1, DS3/E3, OC-3,
OC-3c/STM-1, OC-12c/STM-4c, 10/100BASE-T Ethernet, and serial—the
PSAX 1000 system is a cost-effective access switch solution for connecting to legacy equipment.
PSAX 1250 Multiservice Media Gateway
The PacketStar PSAX 1250 Multiservice Media Gateway is designed to provide a full range of central office-based multiservice ATM access functions.
Ideal for the central office or a large enterprise’s multiservice media gateway, the PSAX 1250 system provides highly reliable network access for time-division multiplex voice, frame relay, 10/100BASE-T Ethernet, and ATM data applications.
When it is functioning in a redundant operating mode and after it has experienced a single-point failure, the PSAX 1250 system provides up to 600 Mbps of ATM cell bus capacity. The total ATM cell bus capacity of the system may also be scaled to provide nonblocking, nonredundant chassis bandwidths beyond 600 Mbps.
Supporting 10 slots (19-inch chassis) or 14 slots (23-inch chassis) for I/O and server modules—with a full range of interfaces such as DS0A, DS1/E1,
DS3/E3, OC-3, OC-3c/STM-1, OC-12c/STM-4c, 10/100BASE-T Ethernet, and serial—the PSAX 1250 system is a cost-effective access switch solution for interworking with legacy equipment.
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
255-700-576
Release 10.0.0
1-3
Chapter 1 Getting Started
About the PacketStar® PSAX Product Family
PSAX 2300 Multiservice Media Gateway
The PacketStar PSAX 2300 Multiservice Media Gateway offers carrier-grade, high-density multiservice ATM access functions. Designed as the multiservice media gateway for the central office or for a large enterprise customer, the
PSAX 2300 system provides network access for time-division multiplex voice, frame relay, 10/100BASE-T Ethernet, and ATM data applications.
When it is functioning in a redundant operating mode and after it has experienced a single-point failure, the PSAX 2300 system provides up to 1.9 Gbps of ATM cell bus capacity. The total ATM cell bus capacity of the system may also be scaled to provide nonblocking, nonredundant chassis bandwidths beyond 1.9 Gbps.
Supporting 15 slots for I/O and server modules—with provisions for OC-3,
OC-3c/STM-1, and OC-12c/STM-4c interfaces with 1:1 protection, 1:1 DS1 module protection switching, and a full range of interfaces such as DS0A,
DS1/E1, DS3/E3, 10/100BASE-T Ethernet, and serial—the PSAX 2300 system solves demanding and diverse network design challenges with ease.
PSAX 4500 Multiservice Media Gateway
The PacketStar PSAX 4500 Multiservice Media Gateway provides carrier-class reliability, with an unmatched range of service capabilities, end-to-end traffic prioritization, “any-service, any-channel” flexibility, and breakthrough voice technology. Ideal for the central office or a large enterprise multiservice media gateway, the PSAX 4500 system provides highly reliable network access for time-division multiplex voice, frame relay, 10/100BASE-T Ethernet, and ATM data applications.
When it is functioning in a redundant operating mode and after it has experienced a single-point failure, the PSAX 4500 system provides up to 4.2 Gbps of ATM cell bus capacity. The total ATM cell bus capacity of the system may also be scaled to provide nonblocking, nonredundant chassis bandwidths beyond 4.2 Gbps.
The high-performance midplane design supports 15 interface slots. Module protection for two groups of four or six multiport DS3, STS-1e, or E3 modules is provided via an N:1 protection scheme using rear access line interface modules. The protection module provides backup so that on the failure of any one of the modules in a group, traffic is maintained. A single PSAX 4500 system at the edge of the carrier network can transition traffic from a large number of network customers over high-speed DS1/E1 IMA, DS3/E3, OC-3,
OC-3c/STM-4c, and OC-12c/STM-4c trunks into the ATM core, managing the whole quickly and efficiently, down to the individual permanent virtual circuit.
Through the use of the latest DSP voice technology, the PSAX 4500 system supports advanced voice traffic over ATM (VToA) services for up to 6048 DS0 channels. As a multiservice media gateway—with H.248 call control, CAS,
PRI, GR-303, and V5.2 protocols, 3-Port DS3/STS-1e, 1-Port OC-3/STM-1
CES, and Tones and Announcements modules—the PSAX 4500 system provides packet solutions for voice over xDSL, trunking, tandem, and PRI offload switching.
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
1-4
Release 10.0.0
255-700-576
Chapter 1 Getting Started
Conventions
Conventions
Text Types Used in This Document
This guide uses a different typeface to denote text displayed on console interface windows and equipment, as well as data you enter. Table 1-1 shows how each typographical convention is used.
Table 1-1.
Text Conventions
Appearance How it is used
SANS SERIF BOLD, ALL CAPS Labels on module panels, chassis faceplates, or other hardware
Fixed-width normal
Serif bold
Fixed-width bold
Serif italics
Message text displayed on the user interface window
• Button name (GUI interface) or command name
(console interface) on the user interface window
• Literal text for values that the user types or selects from predefined sets of values for fields
• Commands or literal argument values
System prompts displayed on the user interface window
• A variable name or string for which you will substitute your own information
• An argument or parameter on a command line for which you will substitute your own information
Icons and Symbols
Refer to the procedures within this guide for important safety information and proper procedures.
Standard icons and symbols to alert you to dangers, warnings, cautions, and notes are described as follows:
!
DANGER:
Warnings for a personal injury hazard are identified by this format.
!
WARNING:
Warnings relating to risk of equipment damage or failure are identified by this format.
!
CAUTION:
Warnings relating to risk of data loss or other general precautionary notes are identified by this format.
Note:
Identifies additional information pertinent to the text preceding this note.
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
255-700-576
Release 10.0.0
1-5
Chapter 1 Getting Started
Conventions
Use of Command Description Tables
All illustrations for configuration windows in this guide for the PSAX system console interface are followed by a command description table describing the command functions displayed on the window (near the bottom of the window). You should read all the information in the command description table, especially when first using a window, because these descriptions may have special instructions or configuration constraints provided in the Function column by use of the Note: text convention (see Table 1-2).
Table 1-2.
Command Description Table Example
Command Function
Bring All Interfaces
Into Service
Brings the out-of-service configured interfaces to in-service status.
Note: In GR-303 configuration, it is critical to bring into service only those channels actively configured with DS1 ports.
Use of Field Description Tables
Identifies editable fields or display-only fields on screens
For all illustrations for configuration windows in this guide for both the
PSAX system console interface and the EMS-PSAX, the field description tables normally follow the command description tables. Field description tables define the editable and the display-only fields, their functions, valid values, and constraints, if applicable. As in the command description tables, the Note: text convention is also used, where appropriate, in the field description tables to alert the user to special instructions or configuration constraints (see Figure 1-1).
Identifies initial field value default
Describes the function of the field and special instructions for configuring modules
Field Name
Interface Type
Field Values
Default: 0
Range: 0-22
Format: Numeric
Description
Specifies the type of end-to-end connection protocol that governs the transmission parameters for this configured port and channel interface.
Note: When certain types of interfaces are selected in this field, other configuration fields are displayed on this window.
Identifies available range for field value when applicable
Identifies field value format as
Numeric, Predefined Alphanumeric,
Hexadecimal, or Valid Dotted Quad.
Figure 1-1.
Field Description Table Example
Decribes special instructions or configuration constraints
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
1-6
Release 10.0.0
255-700-576
Chapter 1 Getting Started
General Navigational Guidelines
General Navigational Guidelines
Selecting Options, Fields, and Commands Using the Console Interface
Follow these guidelines to select an option, field, or command on the PSAX console interface windows and to navigate through the windows:
• To select an option, field, or command, do one of the following:
~ Press the Up, Down, Left, or Right Arrow to highlight (reverse video image) the option name, field name, or command you want to select and press Enter as many times as necessary until the field choice you want is displayed.
~ Use the alternate keys, K=UP, H=LEFT, L=RIGHT to highlight (reverse video image) the option name, field name, or command you want to select and press Enter. (You can optionally redefine these alternate keys from the User Options window, which is accessible from the Console
Interface Main Menu window.)
~ To quickly select a command, you can also simultaneously press Ctrl and the letter underlined in the command.
Once an option name, field, or command is selected, the system responds as described in Table 1-3.
Table 1-3.
System Responses to Selecting Options, Fields, or Commands
For a selected...
option name field command
the following occurs:
The window corresponding to the option name is displayed.
The following variations occur:
• The field entry area is blank or contains the default or previously entered value. Press Enter to enter or change data in this field. Press
Enter again to exit edit mode.
• The field entry area, like the field name, is displayed in reverse video image and contains a predefined set of values, which you can view or select by pressing Enter to navigate forward through these values. To navigate backward through these field values, press Ctrl+H or the
Backspace key.
Read-only fields, which you cannot change, are enclosed in square brackets (example: [LineStatus]).
The following variations occur:
• A message in the information line indicating an error or successful completion of the command is displayed.
• The next higher level or previous window (window name) is displayed.
• The next lower level or succeeding window (window name) is displayed.
• To navigate through the Console windows, use the shortcuts listed in
Table 1-4.
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
255-700-576
Release 10.0.0
1-7
Chapter 1 Getting Started
Help Information
Table 1-4.
Shortcut Keys for Navigating Console Interface Windows
If you want to...
redisplay the previous window redisplay the Console Interface Main Menu window refresh the window
press...
Ctrl+B on the window.
Ctrl+G on the window.
Ctrl+R on the window.
On all the PSAX system windows, each command or menu option has an underlined letter. The control key plus an underlined letter is a shortcut to that command or menu option. You can use the navigation keys and hotkeys with the Caps Lock key on or off. Always observe the status line at the bottom of the window for instructions and information.
Help Information
The Help windows are accessible from any window in the PSAX system console interface. To access the Help windows, press the ? (Question Mark) key on any window. In addition to the Help windows, the Console Interface windows display contextual help in the information line at the bottom of each window. Contextual help provides information about the command or field currently highlighted on that window. The information line also displays error codes and responses to commands. All responses and notifications are recorded in a trap log. See the PacketStar
®
PSAX Simple Network Management
Protocol (SNMP) Trap Reference Guide for details on displaying the trap log and obtaining explanations of the trap messages.
To view the Help windows from the Console Interface Main Menu window, perform the following procedure.
Begin
1 On the window for which help is desired, press the ? (question mark) key.
The Help window for the current console window is displayed (see
Figure 1-2).
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
1-8
Release 10.0.0
255-700-576
Your site name appears here after initial configuration
Chapter 1 Getting Started
Technical Support
Information Line
Figure 1-2.
Main Menu Help Window
2 To display the remaining Help windows for the current console window, press the Down Arrow key.
3 To scroll backward through the Help windows for the current console window, press the Up Arrow key.
4 To exit Help and return to the current console window, press the Enter key.
End
Technical Support
If you experience a problem with the 12-Port Medium-Density
DS1/E1/DS0A CES module, refer to the Lucent Technologies Product Warranty
Registration Information, which accompanied your shipment, for instructions on obtaining support in your area.
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
255-700-576
Release 10.0.0
1-9
Chapter 1 Getting Started
Before You Begin
Before You Begin
in
Before you start configuring and using your new 12-Port Medium-Density
DS1/E1/DS0A CES module (E1mode), be sure you:
• Record your site-specific specifications such as the IP addresses you will use, and the connections and interfaces you will need. Decide which user names and passwords you will assign.
• Make sure you have IP connectivity to all PSAX devices to be managed
• Determine the numbering scheme for any in-band management connections you will be using
Comments on This Guide
To comment on the PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A
CES Module User Guide (E1 Mode) , please complete the comment card at the following web address:
http://www.lucent-info.com/comments/
You can also email your comments to [email protected].
Include the following information:
Title: PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User
Guide (E1 Mode)
Release number: Release 10.0.0
Document number: 255-700-576
Issue number: Issue 1
Publication date: December 2004
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
1-10
Release 10.0.0
255-700-576
2
Module Description
Overview of This Module
The 12-Port Medium-Density DS1/E1/DS0A CES module (Figure 2-1) provides E1 circuit emulation services, including a new Nx64 Kbps CAS mode to support channelized AAL1 tariff services. It also provides a line rate of
2.048 Mbps per E1 port. Each port can be independently configured to provide Nx64 Kbps (fractional T1) structured, channelized and unchannelized circuit emulation service (CES) with Nx64 Kbps CAS, integrated services digital network with a primary rate interface (ISDN PRI) service, and unstructured CES. For a description of the DS1 and DS0A operating modes, see the following PSAX module user guides:
• For DS1 mode, see the PacketStar
®
PSAX 12-Port Medium-Density
DS1/E1/DS0A CES Module User Guide (DS1 Mode), 255-700-592.
• For DS0A mode, see the PacketStar
®
PSAX 12-Port Medium-Density
DS1/E1/DS0A CES Module User Guide (DS0A Mode), 255-700-569.
FAIL
ACTIVE
MD DS1/
E1/DS0A
CES
LOS
Figure 2-1. 12-Port Medium-Density DS1/E1/DS0A CES Module
When configured for E1 circuit emulation service, the module interfaces with
TDM channelized E1 circuits. It converts channelized data (usually voice data) to ATM virtual channels. By using structured (channelized) circuit
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
255-700-576
Release 10.0.0
2-1
Chapter 2 Module Description
Connection Options emulation, this module can adapt a maximum of 31 DS0 channels per port to
ATM virtual channels with individual VPIs and VCIs. Signaling bit transport is also provided, based on ATM Forum standards for CAS. With the
Nx64 Kbps clear channel capability, this module can connect to a device using an ISDN PRI service. Because this structured circuit emulation service can be configured to use only a fraction of the time slots, you can configure several independent emulated circuits to share one service interface.
Connection Options
The 12-Port Medium-Density DS1/E1/DS0A CES module connects to user equipment via a shielded 10-foot Lucent cable assembly (COMCODE
300468030) and a non-protected PSAX patch panel. An equivalent shielded cable with an RJ-48H connector (for example, a Cinch p/n 57-10500-7, 90 o plug, a Cinch p/n 57-30500-4, 180 o
plug, a Cinch p/n 57-10500-271, 270 o plug, or equivalent) on one end may also be used. Cable connector screws and cable tie wraps are provided in a kit with the module. See Figure 2-2 for an illustration of this connection.
Connector
Tie
Bracket with Hole
Cinch p/n
57-10500-7
Figure 2-2. 12-Port MD DS1/E1/DS0A CES Module Cable Connection (with Cinch connector)
The Lucent cable is used to connect the module to one of the following nonprotected patch panels:
• 12-Port BNC Patch Panel (COMCODE 300298569)
(E1 mode only)
• 24-Port RJ Patch Panel (COMCODE 300298551)
• 48-Port RJ Patch Panel (COMCODE 300298544)
This cable and module are not used with the PSAX 24-Port RJ Protection
Patch Panel.
Note:
The Telco connector on this module is not the same as the Mini-
Champ connector on the 12-Port Medium-Density DS1 Multiservice module and the 12-Port Medium-Density DS1 IMA module.
Figure 2-3 and Figure 2-4 show the connectors of two modules connected to a 24-port RJ Patch Panel (COMCODE 300298551).
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
2-2
Release 10.0.0
255-700-576
Chapter 2 Module Description
Connection Options
E1/DS0A
CES
LOS
E1/DS0A
CES
LOS
FAIL
ACTIVE
SERIAL
1 2
LOS
1
3 4
2
3
5 6
4
5
6
FAIL
ACTIVE
DS1
IMA
2
3
4
5
6
1
LOS
FAIL
ACTIVE
DS1
IMA
2
3
4
5
6
1
LOS
FAIL
ACTIVE
DS1
IMA
2
3
4
5
6
LOS
1
FAIL
ACTIVE
DS1
IMA
LOS
TX
RX
LOS
TX
RX
FAIL
ACTIVE
DS3
ATM
TX
LOS
RX
LOS
TX
RX
FAIL
ACTIVE
DS3
ATM
LOS
TX
RX
LOS
TX
RX
FAIL
ACTIVE
DS3
ATM
FAIL
ACTIVE
CPU2
ETHERNET
CONSOLE
LOAD
FAIL
ACTIVE
FAIL
ACTIVE
FAIL
ACTIVE
FAIL
ACTIVE
CPU2
STRATUM
3 4
STRATUM
3 4
Power Supply
( AC )
FAIL
ACTIVE
Power Supply
( AC )
ETHERNET
CLK LOS
CONSOLE
LOAD
CLK LOS
WARNINGS: non-redundant
SEE INSTALLATION
INSTRUCTIONS BEFORE
CONNECTING THIS MODULE
ENSURE FACILITY POWER
IS COMPATIBLE WITH
VOLTAGE RATING OF
THIS MODULE
DANGER: HIGH VOLTAGE
ATTACH POWER
CORD ONLY
WHEN UNIT IS
FULLY SEATED
IN CHASSIS
UNPLUG POWER CORD
BEFORE REMOVING
THIS MODULE
MULTIPLE POWER
CONNECTIONS,
DISCONNECT TWO
POWER CORDS
BEFORE SERVICING
CHASSIS
Connector
Tie
Bracket with Hole
WARNINGS: non-redundant
SEE INSTALLATION
INSTRUCTIONS BEFORE
CONNECTING THIS MODULE
ENSURE FACILITY POWER
IS COMPATIBLE WITH
VOLTAGE RATING OF
THIS MODULE
DANGER: HIGH VOLTAGE
ATTACH POWER
CORD ONLY
WHEN UNIT IS
FULLY SEATED
IN CHASSIS
UNPLUG POWER CORD
BEFORE REMOVING
THIS MODULE
MULTIPLE POWER
CONNECTIONS,
DISCONNECT TWO
POWER CORDS
BEFORE SERVICING
CHASSIS
Figure 2-3. 12-Port Medium-Density DS1/E1/DS0A CES Modules Connected to 24port RJ Patch Panel (Telco frame with modules)
PacketStar
36$;33
Figure 2-4. 12-Port Medium-Density DS1/E1/DS0A CES Modules Connected to 24port RJ Patch Panel (Telco frame with patch panel)
Figure 2-5 and Figure 2-6 show the connectors of four modules connected to a 48-port RJ Patch Panel (COMCODE 300298551).
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
255-700-576
Release 10.0.0
2-3
Chapter 2 Module Description
Software Features
E1/DS0A
CES
LOS
E1/DS0A
CES
LOS
FAIL
ACTIVE
FAIL
ACTIVE
FAIL
ACTIVE
1
E1/DS0A
CES
1
LOS
CES
LOS
1
LOS
DS1
IMA
1
LOS
DS1
IMA
LOS
1
DS1
IMA
LOS
TX
FAIL
ACTIVE
DS3
ATM
TX
LOS
FAIL
ACTIVE
DS3
ATM
LOS
TX
FAIL
ACTIVE
DS3
ATM
3 4
2
3
5 6
4
5
6
2
3
4
5
6
2
3
4
5
6
2
3
4
5
6
RX
LOS
TX
RX
RX
LOS
TX
RX
RX
LOS
TX
RX
FAIL
ACTIVE
CPU2
ETHERNET
CONSOLE
LOAD
FAIL
ACTIVE
FAIL
ACTIVE
FAIL
ACTIVE
FAIL
ACTIVE
CPU2 STRATUM
3 4
STRATUM
3 4
Power Supply
( AC )
FAIL
ACTIVE
Power Supply
( AC )
ETHERNET CLK LOS
CONSOLE
LOAD
CLK LOS
WARNINGS: non-redundant
SEE INSTALLATION
INSTRUCTIONS BEFORE
CONNECTING THIS MODULE
DANGER: HIGH VOLTAGE
ENSURE FACILITY POWER
IS COMPATIBLE WITH
VOLTAGE RATING OF
THIS MODULE
ATTACH POWER
CORD ONLY
WHEN UNIT IS
FULLY SEATED
IN CHASSIS
UNPLUG POWER CORD
BEFORE REMOVING
THIS MODULE
WARNINGS: non-redundant
SEE INSTALLATION
INSTRUCTIONS BEFORE
CONNECTING THIS MODULE
DANGER: HIGH VOLTAGE
ENSURE FACILITY POWER
IS COMPATIBLE WITH
VOLTAGE RATING OF
THIS MODULE
ATTACH POWER
CORD ONLY
WHEN UNIT IS
FULLY SEATED
IN CHASSIS
UNPLUG POWER CORD
BEFORE REMOVING
THIS MODULE
MULTIPLE POWER
CONNECTIONS,
DISCONNECT TWO
MULTIPLE POWER
CONNECTIONS,
DISCONNECT TWO
POWER CORDS
BEFORE SERVICING
CHASSIS
Connector
POWER CORDS
BEFORE SERVICING
CHASSIS
Tie
Bracket with Hole
Figure 2-5. 12-Port Medium-Density DS1/E1/DS0A CES Modules Connected to 48port RJ Patch Panel (Telco frame with modules)
PacketStar
36$;33
Figure 2-6. 12-Port Medium-Density DS1/E1/DS0A CES Modules Connected to 48port RJ Patch Panel (Telco frame with patch panel)
These patch panels are separately orderable. See the PSAX Patch Panels for
PSAX Multiservice Media Gateways Installation Guide, 255-700-117, for instructions. Further connections to user equipment may be made per the specifications outlined in ANSI T1.403-1999. See Appendix A, “Pin Configurations,” for more details.
Software Features
The 12-Port Medium-Density DS1/E1/DS0A CES (E1 Mode) module supports the following services:
• Circuit emulation service (CES):
~ Structured E1 signal transport
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
2-4
Release 10.0.0
255-700-576
Chapter 2 Module Description
Software Features
~ Nx64 Kbps circuit emulation (where 1<=N<=24)
~ Channel-associated signaling (CAS) Nx64
• CAS trunkline
• Integrated services digital network with primary rate interface service (PRI
ISDN) with 64 Kbps clear channel capability for the D-channel
• AAL2 cell formatting for interworking with the DSP2A, DSP2B, DSP2C, and DSP2D Voice Server modules.
Hardware Features
The 12-Port Medium-Density DS1/E1/DS0A CES (E1 Mode) module provides the following hardware features:
• Number of ports: 12
• Connector type: one 25-pair, 100-ohm, RJ-48H, 50-pin Telco connector
(receptacle) (see Appendix A for pinouts)
• Line rate: 2.048 Mbps
• Physical interfaces supported: ANSI T1.403; ITU-T G.703, ITU G.704
• Line encoding mode: HDB3, AMI
• Loopback capabilities: line loopback, local loopback
• Line buildout: N/A
• Framing mode: Time Slot 16 CAS, CCS, CRC-4
• Transmit clock: local timing, loop timing
• Pulse: 200 ns pulse width, per ITU-T G.703
Hardware Specifications
Table 2-1 provides the general physical hardware and environmental specifications for the PSAX I/O module.
Table 2-1. Physical Hardware Specifications for the PSAX I/O Module
Dimensions
Specification Description
17.3 cm H x 2.41 cm W x 24.1 cm D
(6.8 in. H x 0.95 in. W x 9.5 in. D)
Weight
Operating temperature range for all the
PSAX 1250, PSAX 2300, and
PSAX 4500 systems
0.32 kg (0.7 lb.)
0° to 50° C (32° to 122° F)
Operating temperature range for the
PSAX 1000 systems
For AC-powered PSAX 1000 systems:
0° to 50° C (32° to 122° F)
For DC-powered PSAX 1000 systems:
-20° to 60° C (-4° to 140° F) with a cold start minimum of
0° C (32° F)
Operating humidity range for all chassis 5% to 85% relative humidity
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
255-700-576
Release 10.0.0
2-5
Chapter 2 Module Description
Software Features
Table 2-1. Physical Hardware Specifications for the PSAX I/O Module (Continued)
Specification
Operating altitude range for all chassis
Description
60 meters (197 feet) below sea level to 4,000 meters
(13,123 feet) above sea level
-40° to 70° C (-40° to 158° F)
Storage temperature range for all chassis
Storage humidity range for all chassis
0% to 90% noncondensing
Performance and Power Specifications
Table 2-2 provides the chassis speed, power consumption, and memory allocation specifications for this PSAX module.
Table 2-2. Performance and Power Specifications for the PSAX Module
12-Port
Module
Medium-Density
DS1/E1/DS0A CES
Total
Amount of
SDRAM
8 MB
Module
Program and
Data Space
Maximum
Input
Buffer
*
8 MB 2 cells/ port
Output
Buffer
†
16 cells/ port
Chassis
Speed
High
Speed
Maximum
Power
Consumption
11.5 W
*
†
The I/O buffers carry 16,384 cells per megabyte.
Indicates the size of the output buffer followed by the maximum number of 64-byte cells in the output buffer.
Module Placement
The 12-Port Medium-Density DS1/E1/DS0A CES module is installed in any
PSAX chassis slot intended to contain an I/O or server module. If you are installing the module in a newly installed PSAX chassis, be sure to follow your facility site plan for placing this module in the correct location in the chassis.
Ensure that the latest PSAX 1250 Stratum (NS20N053DC) is installed:
• When using this module with the 23-in. PSAX 1250 chassis.
• When operating this module in the DS0A mode with any PSAX 1250 chassis.
LED Indicators
Table 2-3 describes how the LED indicators on the 12-Port Medium-Density
DS1/E1/DS0A CES module faceplate respond to different module conditions.
These LEDs indicate if the module is installed and operating properly.
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
2-6
Release 10.0.0
255-700-576
Chapter 2 Module Description
Loopback Configuration Options
Table 2-3. LED Indicators for the 12-Port Medium-Density DS1/E1/DS0A CES
Module
Module
Status
Initial
Power-On
No
Configured
Ports
One or
More
Configured
Ports
No Cable on
Port
Cable on
Port
LED
FAIL
(red)
ACTIVE
(green)
Lights briefly
Lights briefly
1
1
Not lit
Not lit
Lights only when the module is not functioning
N/A
Lights only when the module is functioning properly
N/A
N/A
N/A
LOS
[Loss of
Signal]
(yellow)
Lights briefly
2
N/A Lights only when a port is configured and no signal is received
Lights • Does not light if signal is being received
• Lights if signal is missing
1
Note: After power is initially applied to the system and the system boot is complete, the FAIL and ACTIVE LEDs indicate whether the module has no configured ports (red), or one or more configured ports (green).
2
Note: After power is initially applied to the system and the system boot is complete, this loss of signal LED indicates whether the port has a cable connected to it.
Loopback Configuration Options
To aid network troubleshooting and testing, loopback capability is provided for the 12-Port Medium-Density DS1/E1/DS0A CES module (E1 mode). The loopback option on the module port and channel configuration window enables you to verify the integrity of a port by transmitting a received signal back to the source. Selecting a loopback option is described in the module configuration procedure.
Figure 2-7 illustrates the line loop and local loop options.
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
255-700-576
Release 10.0.0
2-7
Chapter 2 Module Description
Loopback Configuration Options
Line Loop
Line Driver
Receiver
Port
Connector
Local Loop
Line Driver
Backplane
Connector
Receiver
Figure 2-7. Loopback Configuration Options
Backplane
Connector
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
2-8
Release 10.0.0
255-700-576
3
Configuring Ports and Channels
Using the Console
Overview of This Chapter
This chapter describes how to use the console interface to perform the following tasks on the 12-Port Medium-Density DS1/E1/DS0A CES module:
• “Obtaining General Module Data and Accessing Ports and Channels”
• “Configuring Ports and Channels in the E1 Mode”
• “Saving the Equipment Configuration and Logging Off”
Before You Begin
Be sure to complete the following tasks first before configuring the 12-Port
Medium-Density DS1/E1/DS0A CES module (E1 Mode):
• Configure your basic system (see “Configuring the System for Your Site” in the PacketStar
®
PSAX Multiservice Media Gateway User Guide).
• Configure the Stratum 3–4 module (see “Configuring the Stratum 3–4
Module” in the PacketStar
®
PSAX Multiservice Media Gateway User Guide).
When configuring the 12-Port Medium-Density DS1/E1/DS0A CES module using the console interface, display-only fields are displayed in square brackets ([ ]).
Obtaining General Module Data and Accessing Ports and
Channels
This section describes how to obtain product, model, version, and serial number data about a module from the Equipment Configuration window. In addition, the window provides operational status and alarm conditions on each installed module. You also use this window to access the port and channel configuration windows for the PSAX modules.
Accessing the Equipment Configuration Window
Perform the following procedure to access the Equipment Configuration window.
Begin
1 On the Console Interface Main Menu window, select the Equipment
Configuration option.
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
255-700-576
Release 10.0.0
3-1
Chapter 3 Configuring Ports and Channels Using the Console
Obtaining General Module Data and Accessing Ports and Channels
The Equipment Configuration window is displayed (see Figure 3-1 through Figure 3-5).
2 View the operational and alarm status, software version, PEC, and serial number data of the installed modules.
3 When you are ready to begin configuring the ports and channels of the module, select the line displaying the name of the module you want to configure.
4 Proceed to the section, “Configuring the Ports,” for module configuration procedures.
Note:
The sample Equipment Configuration windows in the following figures may not show the actual module you are configuring.
These figures illustrate the variations of slot configurations for the different PSAX chassis displayed on the Equipment Configuration window.
End
Figure 3-1. Sample Equipment Configuration Window on a PSAX 1000
System (Page 1)
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
3-2
Release 10.0.0
255-700-576
Chapter 3 Configuring Ports and Channels Using the Console
Obtaining General Module Data and Accessing Ports and Channels
Figure 3-2. Sample Equipment Configuration Window on a PSAX 1250
System (Page 1)
Figure 3-3. Sample Equipment Configuration Window on a PSAX 2300 or
PSAX 4500 System (Page 1)
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
255-700-576
Release 10.0.0
3-3
Chapter 3 Configuring Ports and Channels Using the Console
Obtaining General Module Data and Accessing Ports and Channels
Figure 3-4. Sample Equipment Configuration Window on a PSAX 1000,
PSAX 2300, or PSAX 4500 System (Page 2)
Commands
Figure 3-5. Sample Equipment Configuration Window on a PSAX 1250
System (Page 2)
The commands in this window have the following functions.
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
3-4
Release 10.0.0
255-700-576
Chapter 3 Configuring Ports and Channels Using the Console
Obtaining General Module Data and Accessing Ports and Channels
Command
Update Display
Page Down
Page Up
Interface by Name
Go Back to Main Menu
Function
Refreshes the current status of the modules in the PSAX chassis.
Displays the second page of the Equipment Configuration window. This command toggles with Page Up.
Displays the first page of the Equipment Configuration window.
This command toggles with Page Down.
Displays the Interface Name Table window on which you can view all the interface names in the PSAX system.
Redisplays the Console Interface Main Menu window.
Field Description
The display-only fields on this window are described in Table 3-1.
Table 3-1. Equipment Configuration Window Field Descriptions
Slot
Field Name
Module Type
Status
Alarm Status
Field Value
Default: N/A
Range: 1–25, depends on chassis type
Format: Numeric
Displays the slot number in the PSAX chassis.
Default: N/A
Range: N/A
Format: Predefined
Default: Unknown
Range: N/A
Format: Predefined
Unknown
Primary
Standby
Default: No Alarm
Range: N/A
Format: Predefined
Description
Displays the type of the module in the slot. When a module is inserted into the chassis, its name is displayed in the Module Type field next to the slot number. When the module is removed from the chassis, its name is no longer displayed in the Module Type field and is replaced with None.
Displays the operational status of the module.
Indicates that the module has not been configured.
Indicates one of the following:
• at least one port or channel on an I/O module has been configured.
• a CPU module is functioning as the primary CPU module.
Indicates one of the following:
• a module in redundant systems is operating as the standby (backup) module to the primary (active) module.
• a CPU module in redundant systems is functioning as the standby (backup) CPU module.
Displays the present alarm condition of the module.
For the alarm status conditions, see the table “Alarm
Status Descriptions for Modules” following this table.
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
255-700-576
Release 10.0.0
3-5
Chapter 3 Configuring Ports and Channels Using the Console
Obtaining General Module Data and Accessing Ports and Channels
Table 3-1. Equipment Configuration Window Field Descriptions (Continued)
Field Name
SW #
PEC
Serial #
Field Value
Default: N/A
Range: N/A
Format: Predefined
Default: N/A
Range: N/A
Format: Predefined
Default: N/A
Range: N/A
Format: Predefined
Description
Displays the version of PSAX system software with which the modules’ firmware was released. The software version is encoded in the module firmware.
Because not all modules require firmware upgrades with every new PSAX system software release, the software version that is displayed in this window may be lower than the CPU system software that is currently running on the PSAX system. See the most recent Release Note document for the latest software and firmware lineup information.
Displays the product element code (PEC) used to identify and order this type of module. The PEC is encoded in the module bootloader.
Displays the unique serial number of the individual module. The product serial number is encoded in the module firmware. The format of this field is the following:
PSAX System Rel. 6.5.0 and later: 12-digit number in the format:
YYVVDDnnnnnn
, where
YY
= year of manufacture
VV
= vendor ID code (manufacturer and location)
DD
= date code of manufacture (either month or week depending on vendor’s preference)
nnnnnn
= sequential number, which in conjunction with
YY
,
VV
, and
DD
, creates a unique number for each hardware component in the PSAX product line
For existing products with the 10-digit serial number used in Rel. 6.5.0 or later systems, this number is displayed with two preceding zeros.
PSAX Rel. 6.3.0 and earlier: 10-digit number. For products with 12-digit serial numbers used in Rel 6.3.0 or earlier systems, the first two digits (
YY
) are not displayed.
Alarm Status Values
The Alarm Status field on the Equipment Configuration window is described in Table 3-2.
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
3-6
Release 10.0.0
255-700-576
Chapter 3 Configuring Ports and Channels Using the Console
Obtaining General Module Data and Accessing Ports and Channels
Table 3-2. Module Alarm Status Descriptions on the Equipment Configuration Window
Alarm Status
NoAlarm
WrongCardType
LineFailed
Module Type
Affected
Description
I/O and Server Indicates that no alarms have been detected for the module in this slot.
I/O and Server Indicates that one type of module was configured in this slot in the chassis, but a now different module occupies this slot.
All Indicates that the module in this slot is no longer receiving or transmitting signals because the line failed.
Hexadecimal format,
Example:
12345678ABC
CardRemoved
I/O and Server Indicates that one or more ports on the module in this slot currently have a loss of signal. The numbers indicate which ports have a loss of signal. For modules that have more than eight ports not receiving signals, the value in this field is in hexadecimal format.
All Indicates that one of the following events occurred:
• The module in this slot was configured and then removed from the slot.
• Connections on the OC-3, OC-12, STM-1, or STM-4
APS/MSP primary module in this slot were transferred to the standby module. After the transfer occurs, the former primary module then displays CardRemoved in the
Alarm Status field; the former standby module then displays Primary in the Status field.
ReferenceClockFailed Stratum 3–4
CompositeClockFailed Stratum 3–4
Indicates that the timing reference clock on the Stratum module in this slot failed.
Indicates that the timing composite clock on the Stratum module in this slot failed.
Overload Power Supply Indicates that the Power Supply module is operating under an overload condition.
Power Supply Indicates that the power has failed.
PowerFailed
Minus48vFailed Power Supply Indicates that the -48 V dc Power Supply module output failed.
UnknownAlarm I/O and Server Indicates that the reason for failure is not known.
CompleteClockFailed Stratum 3–4 Indicates that the backplane detected a clock error.
PowerFailed Power Supply Indicates that no power is coming into the PSAX chassis.
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
255-700-576
Release 10.0.0
3-7
Chapter 3 Configuring Ports and Channels Using the Console
Configuring the Module
Configuring the Module
The 12-Port Medium-Density DS1/E1/DS0A CES module (E1 mode) has 12 physical ports, which may be used for DS1 circuit emulation services. You must first configure the 12-Port Medium-Density DS1/E1/DS0A CES module
(E1 mode) before setting up connection provisioning. To configure ports and channels for the 12-Port Medium-Density DS1/E1/DS0A CES module in the
DS1 Mode, see the PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES
Module User Guide (DS1 Mode), 255-700-592. To configure ports and channels for the 12-Port Medium-Density DS1/E1/DS0A CES module in the DS0A
Mode, see the PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Mod-
ule User Guide (DS0A Mode) , 255-700-569.
Configuring Ports and Channels in the E1 Mode
To configure the 12-Port Medium-Density DS1/E1/DS0A CES module ports and channels in the E1 mode, perform the following procedure.
Configuring the Ports and Channels
Begin
1 On the Console Interface Main Menu window (see Figure 3-6), select the
Equipment Configuration option and press Enter.
Figure 3-6. Console Interface Main Menu Window (Equipment Configuration
Selected)
The Equipment Configuration window is displayed (see Figure 3-7 and
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
3-8
Release 10.0.0
255-700-576
Chapter 3 Configuring Ports and Channels Using the Console
Configuring the Module
Figure 3-7. Equipment Configuration Window (As Displayed on the PSAX 1250,
PSAX 2300, and PSAX 4500 Console, Page 1)
2 Select Page Down to display page 2 of this window (Figure 3-8).
Figure 3-8. Equipment Configuration Window (As Displayed on the PSAX 1250,
PSAX 2300, and PSAX 4500 Console, Page 2 )
3 On the Equipment Configuration window, select an MD–DS1E1DS0A module in the Card Type column and press Enter. The 12-Port Medium-
Density E1 Port Configuration window is displayed (see Figure 3-9).
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
255-700-576
Release 10.0.0
3-9
Chapter 3 Configuring Ports and Channels Using the Console
Configuring the Module
Commands
Command
Apply Operating Mode Change
Update Display
Figure 3-9. 12-Port Medium-Density E1 Port Configuration Window
This window allows you to select a physical port (1–12) to configure. It also provides the operational status of the channels and interfaces for each port.
The commands in this window have the following functions:
Delete All Interfaces
Function
Changes the mode in which the module will operate. After changing the value to DS1, DS0A, or
E1 in the Operating Mode field, select this command to apply the change. The module reboots and the window reflects your selection.
Note: All interfaces must be unconfigured, out of service, and deleted before using this command.
Updates the values in the fields to show the most current configuration. Use this command to display the most current information in the Line Status field.
Deletes the configured interfaces for the 12 ports.
You must take all interfaces out of service (using the Take All Interfaces Out Of Service command) before you can use this command to delete all the configured interfaces.
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
3-10
Release 10.0.0
255-700-576
Chapter 3 Configuring Ports and Channels Using the Console
Configuring the Module
Command
Go to H.248 TID Configuration
Bring All Interfaces Into Service
Function
Displays the Termination ID Configuration window. This command appears only when H.248
Configuration is enabled. Refer to the Packetstar
H.248 Media Gateway Control User Guide.
Brings the out-of-service configured interfaces for the 12 ports to in-service status.
Take All Interfaces Out Of Service
Takes the in-service configured interfaces for the
12 ports to out-of-service status. You must use this command first before using the Delete All Inter-
faces command.
Go Back to Equipment Configuration Redisplays the Equipment Configuration window.
Field Descriptions
The fields in this window are described in Table 3-3.
Table 3-3. 12-Port Medium-Density E1 Port Configuration Window Field Descriptions
Field Name
Slot: nn
Field Value
Default: N/A
Range: Variable
Format: Numeric
Port (display only) Default: N/A
Range: 1-12
Format: Numeric
# Channels Configured (display only)
Default: 0
Range: 1-31
Format: Numeric
Description
The PSAX chassis slot that the selected module occupies.
The physical port on the module.
The number of channels configured for this port.
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
255-700-576
Release 10.0.0
3-11
Chapter 3 Configuring Ports and Channels Using the Console
Configuring the Module
Table 3-3. 12-Port Medium-Density E1 Port Configuration Window Field Descriptions (Continued)
Field Name
# Interfaces In Service (display only)
Line Status (display only)
Default: No Alarm
Range: N/A
Format: Predefined
Operating Mode
Field Value
Default: 0
Range: 1-31
Format: Numeric
Default: DS1
Range: DS1, DS0A,
E1
Format: Predefined
Description
The number of interfaces configured for this port that are operationally in service.
The alarm status of the physical port. Displays the most current information when a trap message is received or when the Update Display command is selected.
Note: Shows No Alarm when no interfaces are configured.
Specifies the operating mode of the module. To change from one mode to another, select this field and press Enter to display the apprpriate mode. Use the Apply Operating Mode Change command to load the displayed operating mode.
After applying the command, approximately 25 seconds elapse until the PSAX system recognizes the change in operating mode. After the change, it may be necessary to refresh and display the appropriate wording on the window by toggling between this window, the previous window, and back to this window again.
Note: All interfaces must be out of service, deleted, and unconfigured before changing the operating mode.
4 Select the line with the port you want to configure. The 12-Port
Medium-Density E1 Port and Channel Configuration window is dis-
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
3-12
Release 10.0.0
255-700-576
Chapter 3 Configuring Ports and Channels Using the Console
Configuring the Module
Commands
Command
Delete Interfaces: through
Show Straps
Figure 3-10. 12-Port Medium-Density E1 Port and Channel Configuration
Window (Channelization Disabled)
The commands in this window have the following functions:
Apply Port Configuration
Reset Display
View Port Statistics
Function
Deletes a selected range of configured interfaces when channelization has been enabled. Select the command and follow the prompts to enter the channel numbers and delete the selection.
Note: This command does not display when channelization has been disabled.
Note: You must first take the configured interfaces that are in-service to out-of-service (using the Take
All Interfaces Out Of Service command) before you can use this command.
Displays the 12-Port Medium-Density E1 DS0s Strap
Display window.
For the current port, applies the port configuration field values.
Resets the port configuration fields to the last set of saved values.
Displays the 12-Port Medium-Density E1 Port Statistics window.
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
255-700-576
Release 10.0.0
3-13
Chapter 3 Configuring Ports and Channels Using the Console
Configuring the Module
Command Function
Go to H.248 TID Configuration
Displays the Termination ID Configuration window.
This command appears only when H.248 Configuration is enabled. Refer to the Packetstar H.248 Media
Gateway Control User Guide.
Delete All Interfaces On This Port Deletes the configured interface and sets the channel to unconfigured status. The value Unconfig-
ured displays in the Chnl Status field.
Note: You must first take the interface that is in-service to out-of-service (using the Take All Inter-
faces Out Of Service command) before you can use this command.
Bring All Interfaces Into Service
Brings the out-of-service configured interface for the channel to administrative in-service status. An asterisk displays beside all the configured channels when they are administratively or operationally out-of-service.
Note: You must first configure the interface before you can use this command.
Take All Interfaces Out Of Service Takes the in-service configured interface to out-ofservice status. An asterisk displays beside all the configured channels when they are administratively or operationally out-of-service.
Note: You must use this command first before using the Delete All interfaces On This Port command.
Go to Port Diagnostics
Go Back to Card Configuration
Displays the DS1 Port Diagnostics window.
Note: Not supported.
Redisplays the 12-Port Medium-Density E1 Port
Configuration window.
Field Descriptions
5 Enter values in the fields on this window according to the information
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
3-14
Release 10.0.0
255-700-576
Chapter 3 Configuring Ports and Channels Using the Console
Configuring the Module
Table 3-4. 12-Port Medium-Density E1 Port and Channel Configuration Window
Field Descriptions
Field Name
Loopback
Field Value
Default: NoLoop
Range: N/A
Format: Predefined
NoLoop
LocalLoop
Description
Indicates whether the port is to be used for loopback testing and, if so, the type of loopback to be performed.
LineLoop
TestMode
The port will not be used for loopback.
Local loopback will be used on this port. The signal will be received from another module in the chassis, sent through the module circuitry
(including the segmentation and reassembly
(SAR) function) and the chassis backplane to the originating module.
Line loop will be used on this port. The received signal will be sent through the receiver and the line driver, and then back out to the originating point.
Not supported.
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
255-700-576
Release 10.0.0
3-15
Chapter 3 Configuring Ports and Channels Using the Console
Configuring the Module
Table 3-4. 12-Port Medium-Density E1 Port and Channel Configuration Window
Field Descriptions (Continued)
Field Name
Transmit Clock
Field Value
Default: LocalTim-
ing
Range: N/A
Format: Predefined
LocalTiming
Description
Indicates what type of synchronization is used by the interface to maintain proper data flow through the PSAX system and the remote devices connected to the system.
Data Tx Type (Data
Transfer Type)
LoopTiming
Adaptive
SRTS
Default: Unstruc-
tured
Range: N/A
Format: Predefined
Unstructured
Selects a synchronization source (Composite-
Clock, T1BITS, E1ETSI, CompositeClockDS0A,
Freerun, or LineTiming) that is provided through the Stratum 3–4 module.
Selects the recovered clock from the received data and is used as the transmit clock on the selected interface.
Selects an interface buffer to allow different data rates to pass through the PSAX system and prevent overruns or underruns in the traffic. This option is displayed only when the port is configured as Unstructured in the Data Transfer Type field.
Specifies that the Synchronous Residual Time
Stamp technique is being used. SRTS measures the Service Clock input frequency against a network-wide synchronization signal that must be present in the IWF remote device. This signal sends difference signals, called Residual Time
Stamps, in the AAL1 header to the reassembly
IWF. At the output IWF, the differences can be combined with the network-wide synchronization signal to re-create the input Service clock.
This option is displayed when the CE port is configured as Unstructured in the Data Transfer
Type field. To use SRTS, you must select the value
CircuitEmulation in the Interface Type field on the channel configuration window, and the value
Unstructured in the Data Tx Type field on the port configuration window.
Indicates whether this port has structured or unstructured interfaces.
Structured
Indicates that this port has unstructured (and unchannelized) interfaces.
Note: When you select this value, the Channelization, Time Slot 16, CRC-4, and UpStrmIntrworking, fields are not displayed.
Indicates that this port supports Nx64 Kbps channelized interfaces.
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
3-16
Release 10.0.0
255-700-576
Chapter 3 Configuring Ports and Channels Using the Console
Configuring the Module
Table 3-4. 12-Port Medium-Density E1 Port and Channel Configuration Window
Field Descriptions (Continued)
Field Name
Channelization
Time Slot 16
CRC-4
Ccs
Cas
Field Value
Default: Disabled
Range: N/A
Format: Predefined
Disabled
Enabled
Default: Ccs
Range: N/A
Format: Predefined
Default: Enabled
Range: N/A
Format: Predefined
Enabled
Disabled
Description
Indicates whether the E1 port is divided into 31 channels.
Note: When you select the value Unstructured in the Data Tx Type field, the Channelization field is not displayed.
Indicates that the division of the E1 port into 31 channels is disabled. Use this setting if you want to set up only one channel for the port. When you select the Apply Port Configuration command, only channel 1 displays the value Uncon-
figured.
Indicates that the division of the E1 port into 31 channels is enabled. Use this setting if you want to set up more than one channel for the port.
Indicates the type of signaling selected.
Note: When you select the value Unstructured in the Data Tx Type field, the Time Slot 16 field is not displayed.
Indicates that Time Slot 16 is used for common channel signaling.
Indicates that Time Slot 16 is used for channelassociated signaling.
Indicates the status of the CRC-4 framing mode for the port.
Note: When you select the value Unstructured in the Data Tx Type field, the CRC-4 field is not displayed.
Indicates that CRC-4 is enabled.
Indicates that CRC-4 is disabled.
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
255-700-576
Release 10.0.0
3-17
Chapter 3 Configuring Ports and Channels Using the Console
Configuring the Module
Table 3-4. 12-Port Medium-Density E1 Port and Channel Configuration Window
Field Descriptions (Continued)
Field Name Field Value
UpStrmIntrworking Default: TrunkCond
Range: N/A
Format: Predefined
SG Feature
TrunkCond
Unframed1s
Default: Disabled
Range: N/A
Format: Predefined
Disabled
Description
Displays the communications mode selected between the CE and ATM sides of a connection on this port during alarm conditions.
Note: When you select the value Unstructured in the Data Tx Type field, the UpStrmIntrworkingInterworking Type field is not displayed.
Indicates that trunk conditioning will be done for each channel of this port whose corresponding
ATM side is alarmed. This improves the communication of the trunk status for TDM traffic. See the PacketStar PSAX Multiservice Media Gateway
Trunk Conditioning Application Note for more details.
Indicates that a sequence of Unframed All 1s will be transmitted to the CES end point whenever there is an alarm on the ATM side for any CE to
ATM connection on this port.
Displays the status of the connection gateway feature.
Enabled
Indicates that the connection gateway feature is disabled. See the PacketStar
®
Connection Gateway
API Specification for more details.
Indicates that the connection gateway feature is enabled.
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
3-18
Release 10.0.0
255-700-576
Chapter 3 Configuring Ports and Channels Using the Console
Configuring the Module
Table 3-4. 12-Port Medium-Density E1 Port and Channel Configuration Window
Field Descriptions (Continued)
Field Name
CT Mode
Line Build Out Default: Short
Range: N/A
Format: Predefined
Short
Field Value
Default: Four-Wire
Range: N/A
Format: Predefined
Four-Wire
Two-Wire
Description
H.248 Applications, Continuity Test Mode:
The
SG Feature field
must
be set to Enabled to use any setting in this field. The CT Mode specifies the remote continuity test mode, where you can select Four-Wire or Two-Wire. This parameter supports the H.248 Basic Continuity Package. In a local- and remote-end PSAX System configuration, either with other PSAX Systems or non-
PSAX switches, the PSAX can act as either the tester
*
or testee. See the “PSAX System as
Tester/Testee” tables after this Field Description
Table for a summary of signal strengths that are exchanged in the above configurations, and other pertinent information.
Indicates that the remote end uses a four-wire termination. As the tester, the PSAX transmits a
2010Hz signal if the other termination is 4-wire.
As the testee, the PSAX acts in loopback mode if the other termination is 4-wire.
As the tester, the PSAX transmits a 1780Hz signal if the other termination is 2-wire. As the testee, the PSAX acts in transponder mode if the other termination is 2-wire.
Indicates the selectable output attenuation for the line.
Long
Indicates the E1 signal level is transmitted to be received from 0 to 133 feet
Indicates the E1 signal is transmitted to be received from 0 to 266 feet
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
255-700-576
Release 10.0.0
3-19
Chapter 3 Configuring Ports and Channels Using the Console
Configuring the Module
Table 3-4. 12-Port Medium-Density E1 Port and Channel Configuration Window
Field Descriptions (Continued)
Field Name
[Line Coding]
[Line Status] (display only)
Chnl_Status
Field Value
Default: Hdb3
Range: N/A
Format: Predefined
Description
Indicates the type of line coding to be used on this port. (The data format that lets either end of the communications channel correctly interpret messages from the other.)
Hdb3
Default: NoAlarm
Range: N/A
Format: Predefined
High-density bipolar of order 3 (HDB3). A bipolar coding method that does not allow more than 3 consecutive zeros.
Indicates the status of the line: NoAlarm,
LossOfSignal, or one of several alarms. See the line status table for the E1 mode below.
Default: 1 Unconfig
Range: 1 (unchannelized);1-31 (channelized)
Format: Predefined
Displays the interface configuration status of the channel. Select this field to access the 12-Port
Medium-Density E1 Channel Configuration window and configure an interface. When the interface for the channel is configured, the interface type displays in this field. An asterisk beside the interface type indicates that the interface is not in service.
*
The PSAX System side of a local/remote configuration can function as the tester or the testee in configuration with another PSAX, a non-PSAX switch, and a media gateway controller (MGC).
Regardless of tester or testee status, the PSAX system side is always 4-wire. When interfacing with a 2-wire device, the PSAX converts its 4-wire signal (2010-Hz) to a 2-wire (1780-Hz) signal when replying to a 2-wire device, thus operating in transponder mode. As the testee, the PSAX system can act in loopback mode if the remote end is 4-wire. The loopback mode is configured on the
Media Gateway Controller configured with the PSAX system. The signaling call progress tones
(dial, ringing, busy, congestion, special information, caller waiting) are generated from the TAS module in CAS mode in configuration with the MGC. All other signals, such as continuity check and the 10x tests (102, 105, and 108) are generated from the TAS module in TAS mode. See the
Tones and Announcements Server Module User Guide for more information.
\
Table 3-5. PSAX System as Tester (ct/ct)
If the testee is...
4-wire
2-wire
then the PSAX system transmits...
a 2010-Hz signal a 1780-Hz signal
and the PSAX system expects to receive...
a 2010-Hz signal a 2010-Hz signal
Table 3-6. PSAX System as Testee (ct/rsp)
If the tester is...
4-wire
2-wire
then the PSAX system expects to receive...
a 2010-Hz signal a 2010-Hz signal
and the PSAX system returns...
a 2010-Hz signal a 1780-Hz signal
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
3-20
Release 10.0.0
255-700-576
Chapter 3 Configuring Ports and Channels Using the Console
Configuring the Module lLine Status Alarms
The following table shows line status alarms for the 12-Port MD
DS1/E1/DS0A CES module (E1 mode):
Table 3-7. E1 Line Status Alarms
Alarm
NoAlarm
RcvFarEndLOF
XmtFarEndLOF
RcvAIS
XmtAIS
LossOfFrame
LossOfSignal
LoopbackState
T16AIS
RcvFarEndLOMF
XmtFarEndLOMF
RcvTestCode
OtherFailure
Description
No alarm present
PSAX is receiving an RAI alarm. The RAI (yellow) alarm is usually sent by the far-end device when an LOS, AIS, or LOF condtion is detected on its receive port.
Near-end sending LOF indication
Far-end sending AIS (red alarm)
Near-end sending AIS
Near-end LOF
Near-end loss of signal
Near-end is looped
E1 TS16 AIS
Far-end sending TS16 LOMF
Near-end sending TS16 LOMF
Near-end detects a test code
Any other line status not shown in this table
6 To configure channels, perform one of the following procedures:
Table 3-8. Configuring Channels
If you want to configure...
the port as one channel, several channels for a port,
then...
you must have selected the value
Disabled in the Channelization field
(see Table 3-4). Continue with
instructions in “Configuring a Port with One Channel”.
you must have selected the value
Enabled in the Channelization field
(see Table 3-4). Continue with
instructions in ”Configuring a Port with Several Channels” on page 3-25.
End
Configuring a Port with One Channel
Configuring a Port with One Channel
Begin
To configure one or more ports on the 12-Port Medium-Density DS1/DS0A
CES module with only one channel for a port, proceed as follows:
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
255-700-576
Release 10.0.0
3-21
Chapter 3 Configuring Ports and Channels Using the Console
Configuring the Module
1 Select 1 Unconfigured on the 12-Port Medium-Density E1 Port and
Channel Configuration window (see Figure 3-10).
Note:
You must have selected the value Disabled in the Channelization field on the 12-Port Medium-Density E1 Port and Channel
Configuration window.
The 12-Port Medium-Density E1 Channel Configuration window (see
Figure 3-11. 12-Port Medium-Density E1 Channel Configuration Window (One
Channel per Port)
Commands
The commands in this window have the following functions:
Command
Apply Configuration
Reset Display
Resets the fields to the last set of saved values.
Go to H.248 TID Configuration
Displays the Termination ID Configuration window. This command appears only when H.248
Configuration is enabled. Refer to the Packetstar
H.248 Media Gateway Control User Guide.
Bring Interface Into Service
Function
For a specified port and channel number value, applies the interface configuration you selected.
Take Interface Out Of Service
Brings the out-of-service configured interface to in-service status. The value InService is displayed in the [Admin Status] field.
Takes the in-service configured interface to outof-service status. The value OutOfService is displayed in the [Oper Status] and the [Admin
Status] fields.
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
3-22
Release 10.0.0
255-700-576
Chapter 3 Configuring Ports and Channels Using the Console
Configuring the Module
Command
Configure Interface
Go Back to Port Configuration
Function
Displays an interface configuration window for the selected interface.
Redisplays the 12-Port Medium-Density E1 Port and Channel Configuration window.
Field Descriptions
2 Enter values in the fields on this window according to the information
Table 3-9. 12-Port Medium-Density E1 Channel Configuration Window Field Descriptions
Field Name
[Slot: nn]
Port: nn
Channel: nnn
Interface Type
Field Value
Default: N/A
Range: Variable
Format: Numeric
Default: N/A
Range: 1-12
Format: Numeric
Default: 001
Range: 001-031
Format: Numeric
Description
The PSAX chassis slot that the selected module occupies.
The physical port on the module.
Indicates the channel selected.
Note: Only channel 001 is available when channelization is disabled.
Default: Unconfig-
ured
Range: N/A
Format: Predefined
Indicates the type of end-to-end connection protocol that governs the transmission parameters of the configured channel interface.
Note: Only CircuitEmulation is available when channelization is disabled.
Unconfigured
This interface is not configured.
CircuitEmulation
This interface is configured for the circuit emulation interface.
CasTrunkLine
This interface is configured for the CAS trunkline interface. To apply this interface, Channelization must be Enabled and the Time Slot 16 Cas value selected.
Pri-isdn-network
This interface is configured for the PRI ISDN network interface. To apply this interface, Channelization and the SG Feature must be Enabled.
Pri-isdn-user
This interface is configured for the PRI ISDN user interface. To apply this interface, Channelization and the SG Feature must be Enabled.
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
255-700-576
Release 10.0.0
3-23
Chapter 3 Configuring Ports and Channels Using the Console
Configuring the Module
Table 3-9. 12-Port Medium-Density E1 Channel Configuration Window Field Descriptions (Continued)
Field Name
[Admin Status]
Field Value
Range: N/A
Format: Predefined
Disabled
Enabled
Description
Indicates signaling status on the configured interface. When channelization is disabled and Cir-
cuitEmulation is selected, this field is display only.
Indicates that signaling is disabled. This interface uses common channel signaling (CCS).
Indicates that signaling is enabled. This interface uses channel-associated signaling (CAS).
Displays the administrative status of the selected channel.
Default: Unconfig-
ured
Range: N/A
Format: Predefined
Unconfigured
InService
[Oper Status]
OutOfService
Default: Unconfig-
ured
Range: N/A
Format: Predefined
Unconfigured
The interface for the channel is not configured.
The interface has been brought into service with the Bring Interface Into Service command.
The interface has not yet been brought into service, or its in-service interface has been set to out of service with the Take Interface Out of Ser-
vice command.
Displays the operational status of the selected channel and whether the channel is exchanging a valid signal.
[Available DS0s]:
[DS0s Strapped]
InService
OutOfService
Default: N/A
Range: 01-31
Format: Numeric
Default: N/A
Range: 01-31
Format: Numeric
This channel is not operational because the interface is not configured.
The configured interface is currently operational, that is, capable of receiving and sending signals.
The configured interface is not currently operational, that is, not capable of receiving and sending signals, because no connection exists.
Indicates the number of unchecked DS0s available to be strapped to a particular channel. DS0s are only available when channelization is enabled. This field is not displayed when channelization is disabled.
Indicates the number of checked DS0s strapped to a particular channel. When channelization is disabled, all 31 DS0s are strapped to channel 001.
3 Select an interface in the Interface Type field. The Signaling field appears when you make the following selections: CircuitEmulation,
CasTrunkLine.
4 In the Signaling field, select either Disabled (default) or Enabled.
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
3-24
Release 10.0.0
255-700-576
Chapter 3 Configuring Ports and Channels Using the Console
Configuring the Module
5 Select the Apply Configuration command. The selected interface type is applied. For example, a trap message in the status bar reads:
T-InterfaceCreated: interfaceIndex=801001 interfaceType=CircuitEmulation.
6 Select the Bring Interface Into Service command and press Enter. The selected interface type is brought into service.
Note:
Use this command only if you want to accept the default field values on the interface configuration window. Otherwise, skip this step. To select and apply field values on the interface configuration window, the interface must be out of service.
7 Select the Configure Interface command and press Enter.
An interface configuration window is displayed for the interface type selected.
See the PacketStar
®
PSAX Connections Provisioning Guide for a description of this window.
8 Repeat “Configuring Ports and Channels in the E1 Mode”, and steps 1-7
under “Configuring a Port with One Channel” for the remainder of the
ports, as needed.
Note:
Be sure to complete the module port and channel configuration and then the interface configuration for each port before beginning the configuration of a new port.
You can save the values permanently to the Multiservice Media Gateway system database now, or before you exit the current session of the Multiservice Media Gateway system console interface. See “Saving the Equip-
ment Configuration and Logging Off” on page 3-30.
End
Configuring a Port with Several
Channels
Configuring a Port with Several Channels
Begin
To configure one or more ports on the 12-Port Medium-Density
DS1/E1/DS0A CES module with several DS0s strapped together in one channel and several channels for a port, proceed as follows:
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
255-700-576
Release 10.0.0
3-25
Chapter 3 Configuring Ports and Channels Using the Console
Configuring the Module
1 Select 1 Unconfigured on the 12-Port Medium-Density E1 Port and
Channel Configuration window (see Figure 3-12).
Figure 3-12. 12-Port Medium-Density E1 Port and Channel Configuration
Window (Channelization Enabled)
Note:
You must have selected the value Enabled in the Channelization field on this window.
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
3-26
Release 10.0.0
255-700-576
Chapter 3 Configuring Ports and Channels Using the Console
Configuring the Module
The 12-Port Medium-Density DS1 Channel Configuration window (see
Figure 3-13. Medium Density 12-Port E1 Channel Configuration Window (Several
Channels per Port)
See page 3-22 for a description of the commands and fields in this window.
2 Select an interface in the Interface Type field. The Signaling field appears when you make the following selections: CircuitEmulation,
CasTrunkLine.
3 In the Signaling field , select either Disabled (default) or Enabled.
4 In the [Available DS0s] field, move the cursor to value 01 (indicates DS0
1) and press Enter to display x below DS0 01.
5 Move the cursor to the next DS0 value and press Enter to display x below the DS0 value. Select as many DS0s as you want to strap together for the selected channel.
6 Select the Apply Configuration command. The selected interface type is applied. For example, a trap message in the status bar reads:
T-InterfaceCreated: interfaceIndex=801001 interfaceType=CircuitEmulation.
In the [DS0s Strapped] field (display only), the values for the DS0s you just selected are displayed.
7 To strap together more DS0s for another channel in the selected port, reselect the Channel field, enter the next channel number, for example,
002, and repeat steps 2-6 from the DS0s available.
8 Select the Bring Interface Into Service command. The selected interface type is brought into service.
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
255-700-576
Release 10.0.0
3-27
Chapter 3 Configuring Ports and Channels Using the Console
Configuring the Module
Note:
Use this command only if you want to accept the default field values on the interface configuration window. Otherwise, skip this step. To select and apply field values on the interface configuration window, the interface must be out of service.
9 Select the Configure Interface command. An interface configuration window is displayed for the interface type selected.
See the PacketStar
®
PSAX Connections Provisioning Guide for a description of this window.
10 Repeat step 2-9 for the rest of the available DS0s (or as many as you want to use).
Note:
Be sure to complete the module port and channel configuration and then the interface configuration for each port before beginning the configuration of a new port.
11 To view the strapped DS0s and their associated channels at any time, select the Show Straps command on the 12-Port Medium-Density E1
Port and Channel Configuration window (see Figure 3-12). The 12-Port
Medium-Density E1 DS0s Strap Display window (see Figure 3-14) is dis-
played.
Commands
Figure 3-14. 12-Port Medium-Density E1 DS0s Strap Display Window
Note:
The strapped DS0s you set up are displayed next to their associated channels.
The commands in this window have the following functions:
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
3-28
Release 10.0.0
255-700-576
Chapter 3 Configuring Ports and Channels Using the Console
Configuring the Module
Command
Update Display
Function
Resets the fields to the last set of saved values.
Go Back to E1 Port Configuration
Redisplays the 12-Port Medium-Density E1 Port and Channel Configuration window.
Field Descriptions
The fields in this window are described in Table 3-10.
End
Viewing Port Statistics
Viewing 12-Port Medium-Density E1 Port Statistics
Begin
To view statistics for a port, from the 12-Port Medium-Density E1 Port and
Channel Configuration window (Figure 3-12), select the View Port Statis-
tics command. The 12-Port Medium-Density E1 Port Statistics window (see
Figure 3-15. 12-Port Medium-Density E1 Port Statistics Window
Commands
The commands in this window have the following functions:
Command
Continuous Update
Function
Updates the values in the fields every second.
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
255-700-576
Release 10.0.0
3-29
Chapter 3 Configuring Ports and Channels Using the Console
Saving the Equipment Configuration and Logging Off
Command Function
Reset Statistics
Sets all field values to 0.
Go Back to E1 Port Configuration
Redisplays the 12-Port Medium-Density E1
Port and Channel Configuration window.
Field Descriptions
The fields in this window are described in Table 3-11.
Table 3-11. 12-Port Medium-Density E1 Port Statistics Window Field Descriptions
Field Name
Errored Seconds
Severely Errored
Seconds
Line Coding Violations
Time Elapsed
Field Value
Default: 0000000000
Range: N/A
Format: Numeric
Default: 0000000000
Range: N/A
Format: Numeric
Default: 0000000000
Range: N/A
Format: Numeric
Default: 0:00:00
Range: N/A
Format: hh:mm:ss
Description
Displays the number of errored seconds that have occurred on the E1 port since the last time statistics were reset. An errored second contains at least one of the following:
• Path Code Violations
• Controlled Slip events
• A detected AIS defect
• Presence of Bipolar Violations.
Displays the number of severely errored seconds that have occurred on the E1 port since the last time statistics were reset. A severely errored second contains at least one of the following:
• 320 or more Path Code Violation Error events
• Out of Frame defects
• A detected AIS defect
• A count of one-second intervals with Framing error events, an OOF defect, or a minimum of
1544 LCVs.
Displays the number of line coding violations that have occurred on the E1 port since the last time statistics were reset. Line coding violations indicate that a bipolar violation or an excessive zeroes error event has occurred.
Displays the time elapsed, in hours, minutes, and seconds, since the last time statistics were reset
Saving the Equipment Configuration and Logging Off
After configuring the module ports and channels, the interface types for each port and channel, and the connections, you must save the values to the
PSAX system database. It is recommended that you save your values frequently as you progress through your work, at a minimum, after finishing each stage of work:
• Configuring each module in your system
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
3-30
Release 10.0.0
255-700-576
Chapter 3 Configuring Ports and Channels Using the Console
Saving the Equipment Configuration and Logging Off
• Configuring the connections in your system
• Before exiting your current console session
Perform the following procedure to permanently save the values for your system.
!
CAUTION:
If your system loses power or if you reboot the chassis, and you have not yet saved the values permanently, you will lose all unsaved values you have applied on the various windows.
Begin
1 Press Ctrl+G, to return to the Console Interface Main Menu window.
On the Console Interface Main Menu window, [Modified] is displayed next to the Save Configuration command, indicating you have made changes to the system that are not yet saved to the PSAX system database
(see Figure 3-16).
Figure 3-16. Save Configuration [Modified] (Before Saving)
2 Select the Save Configuration command or press Ctrl+A.
Wait a few seconds while the system writes the values to the PSAX system database. The system displays the following message while it is executing this command:
Saving the equipment and connection information
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
255-700-576
Release 10.0.0
3-31
Chapter 3 Configuring Ports and Channels Using the Console
Provisioning Connections
Note:
In PSAX systems with redundant CPUn modules, the standby
CPUn module reboots every time you save the configuration on the primary CPUn module. This event is a function of the SVC retention feature and the result of saving the configuration changes you have made.
When the save configuration function is completed, the system displays an appropriate message as described in Table 3-12.
Table 3-12. Messages Generated after the Save Configuration Process
When a PSAX system is...
the system displays...
nonredundant
T-SaveConfiguration: saveConfigurationReasonCode=All-OK redundant
T-SaveConfiguration: saveConfigurationReasonCode =
Expect2ndCPUCardFailedOrRemoved
*
The standby CPUn module is rebooted when the save command is issued.
After the standby CPUn module reboots, the system displays the following message:
T-SaveConfiguration: saveConfigurationReason-
Code=FileTransferCompleted
*
This message indicates that while the standby CPUn module reboots after you select the
Save
Configuration
command, the standby CPUn module is temporarily unavailable.
End
After saving the configuration values, the indicator [Modified] is no longer displayed next to the Save Configuration command.
Provisioning Connections
For instructions on configuring interfaces and provisioning connections, see your PacketStar
®
PSAX Connections Provisioning Guide. In using that guide, keep in mind that the following connection types are supported by the 12-Port
Medium-Density DS1/E1/DS0A CES module (E1 mode):
• PVC connections:
~ Circuit Emulation-to-ATM virtual channel connection (VCC)
~ Circuit Emulation-to-Circuit Emulation channel connection (VCC)
~ GR-303-to-AAL2 VCC/PVC channel connection
• SPVC connections:
~ Circuit Emulation-to-ATM virtual channel connection (VCC)
~ Circuit Emulation-to-ATM Std AAL2 virtual channel connection (VCC)
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
3-32
Release 10.0.0
255-700-576
A
Pin Configurations
Overview of This Appendix
This appendix describes the pin assignments for the connectors on the 12-
Port Medium-Density DS1/E1/DS0A CES module. Use the following information to connect correctly configured cables to this module.
Configurations for the 12-Port MD DS1/E1/DS0A CES
Module Connectors
The following table shows the pin configurations for the 12-Port
Medium-Density DS1/E1/DS0A CES module connector. Each port consists of two transmit and two receive pins. Note that two pins are not used.
Table A-1. Telco Connector Pin Assignments for the 12-Port
Medium-Density DS1/E1/DS0A CES Module
Top Row
Ring Pin #
13
14
15
16
9
10
11
12
17
18
19
20
7
8
5
6
3
4
1
2
Bottom Row
Tip Pin #
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
Network
Signal Pair
Connector
Tx 1
Tx 2
Tx 3
Tx 4
Tx 5
Tx 6
Tx 7
Tx 8
Tx 9
Tx 10
Tx 11
Tx 12
Port
Connector
1
2
3
4
5
6
7
8
9
10
11
12
Do Not Use Do Not Use
Rx 1 1
Rx 2
Rx 3
Rx 4
Rx 5
Rx 6
Rx 7
2
3
4
5
6
7
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
255-700-576
Release 10.0.0
A-1
Appendix A Pin Configurations
Configurations for the 12-Port MD DS1/E1/DS0A CES Module Connectors
Table A-1. Telco Connector Pin Assignments for the 12-Port
Medium-Density DS1/E1/DS0A CES Module
Top Row
Ring Pin #
21
22
23
24
25
Bottom Row
Tip Pin #
46
47
48
49
50
Network
Signal Pair
Connector
Rx 8
Rx 9
Rx 10
Rx 11
Rx 12
Port
Connector
8
9
10
11
12
The 12-Port Medium-Density DS1/E1/DS0A CES module port connector mates with a shielded 10-foot Lucent cable assembly (COMCODE
300468030). An equivalent shielded cable with an RJ-48H connector (for example, a Cinch p/n 57-10500-7, 90° plug, a Cinch p/n 57-30500-4, 180° plug, a Cinch p/n 57-10500-271, 270° plug, or equivalent) may also be used(see Chapter 2, ”Module Description,” and Figure A-1). The pin wiring for this cable, shown in Table A-2, details the RJ-48H network connection to the user equipment. You can connect to this cable per the specifications outlined in ANSI T1.403-1999.
13
14
15
16
09
10
11
12
05
06
07
08
01
02
03
04
21
22
23
24
25
17
18
19
20
Figure A-1. Pin Locations on the Telco Port Socket Connector
38
39
40
41
34
35
36
37
30
31
32
33
26
27
28
29
46
47
48
49
50
42
43
44
45
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
A-2
Release 10.0.0
255-700-576
Appendix A Pin Configurations
Configurations for the 12-Port MD DS1/E1/DS0A CES Module Connectors
Table A-2. Standard 25-Pair Telco Connector to RJ-48H Cable Wiring
Telco Socket
Pin
RJ-48H Pin Twisted Pair
1 1 1
5
5
6
4
4
3
3
Port
Connector
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
Signal Name
TRING_1
TTIP_1
TRING_2
TTIP_2
TRING_3
TTIP_3
TRING_4
TTIP_4
TRING_5
TTIP_5
TRING_6
TTIP_6
TRING_7
TTIP_7
TRING_8
TTIP_8
TRING_9
TTIP_9
TRING_10
TTIP_10
TRING_11
TTIP_11
TRING_12
TTIP_12
Do Not Use Do Not Use
Do Not Use Do Not Use
2
2
1
1
RRING_1
RTIP_1
RRING_2
RTIP_2
RRING_3
RTIP_3
RRING_4
RTIP_4
RRING_5
RTIP_5
RRING_6
16
41
17
42
14
39
15
40
18
43
19
12
37
13
38
10
35
11
36
8
33
9
34
6
31
7
32
4
29
5
30
2
27
3
28
16
41
17
42
14
39
15
40
18
43
19
12
37
13
38
10
35
11
36
8
33
9
34
6
31
7
32
4
29
5
30
2
27
3
28
16
16
17
17
14
14
15
15
18
18
19
12
12
13
13
10
10
11
11
9
9
8
8
7
7
6
6
5
5
4
4
3
3
2
2
Wire Color
Blue/White
Gray/Red
Red/Gray
Blue/Black
Black/Blue
Orange/Black
Black/Orange
Green/Black
Black/Green
Brown/Black
Black/Brown
Gray/Black
Black/Gray
Blue/Yellow
Yellow/Blue
Orange/Yellow
Yellow/Orange
Green/Yellow
Yellow/Green
Brown/Yellow
Orange/White
White/Orange
Green/White
White/Green
Brown/White
White/Brown
Gray/White
White/Gray
Blue/Red
Red/Blue
Orange/Red
Red/Orange
Green/Red
Red/Green
Brown/Red
Red/Brown
Input/Output
N/A
N/A
Input
Input
Input
Input
Input
Input
Output
Output
Output
Output
Output
Output
Output
Output
Input
Input
Input
Input
Input
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
255-700-576
Release 10.0.0
A-3
Appendix A Pin Configurations
Configurations for the 12-Port MD DS1/E1/DS0A CES Module Connectors
Table A-2. Standard 25-Pair Telco Connector to RJ-48H Cable Wiring (Continued)
11
12
12
9
10
10
11
Port
Connector
6
7
8
9
7
8
Signal Name
RTIP_6
RRING_7
RTIP_7
RRING_8
RTIP_8
RRING_9
RTIP_9
RRING_10
RTIP_10
RRING_11
RTIP_11
RRING_12
RTIP_12
Telco Socket
Pin
44
20
45
21
46
22
47
23
48
24
49
25
50
RJ-48H Pin
44
20
45
21
46
22
47
23
48
24
49
25
50
Twisted Pair
21
22
22
23
19
20
20
21
23
24
24
25
25
Wire Color
Yellow/Brown
Gray/Yellow
Yellow/Gray
Blue/Violet
Violet/Blue
Orange/Violet
Violet/Orange
Green/Violet
Violet/Green
Brown/Violet
Violet/Brown
Gray/Violet
Violet/Gray
Input/Output
Input
Input
Input
Input
Input
Input
Input
Input
Input
Input
Input
Input
Input
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
A-4
Release 10.0.0
255-700-576
B
Reference Information
Overview of This Appendix
This appendix contains reference information that is helpful while configuring your PSAX system. The following types of information are provided:
• “Avoiding Common Errors When Configuring Interfaces”
• “Optimizing SVC Call Performance”
• “Connection Type by Interface Type”
• “Connection Type by Interface Type”
• “Interface Type by I/O Module Type”
• “Minimum AAL2 Trunk Size Requirements Tables”
• “Module Alarm Status Descriptions”
• “ATM Service Categories in the PSAX System”
Avoiding Common Errors When Configuring Interfaces
An error may occur when you apply an interface to a channel. If an error condition occurs, the PSAX system sends an SNMP trap that is usually displayed in the console Trap Log Display window (accessible from the Console
Interface Main Menu window). The list below includes the most common interface errors that cause the PSAX system to display a message. (See the
PacketStar
®
PSAX Simple Network Management Protocol (SNMP) Trap Reference
Guide for more information about the SNMP traps related to interface errors).
• Entering field values that are outside of the configurable range of values
• Attempting to configure an interface for a port or channel that has already been configured
• Attempting to configure an interface that is already in service (must be out of service to be configured or change field values)
• Entering field values that are not recognized by the PSAX system software
Optimizing SVC Call Performance
The information in this section provides guidance on optimizing call performance when configuring SVCs on the PNNI interface. The service-specific connection-oriented protocol (SSCOP) parameter is set on these interface configuration windows: ATM IISP network or IISP user, ATM UNI 3.0 or
UNI 3.1, or ATM PNNI 1.0.
Note:
These settings are suggested for connecting to a PSAX system from a remote site only. The PSAX system configures these settings internally in its own ATM switch.
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
255-700-576
Release 10.0.0
B-1
Appendix B Reference Information
DSP Tone Detection Modes
When unacknowledged protocol data units (PDUs), the MaxPD field on the remote end peer (such as the NavisCore™ CBX 500™) shows the maximum number of SSCOP packets transmitted since the last PSAX polling of the peer.
To optimize call performance, the SSCOP Rx Window Size field of the local
ATM interface should be less than the maximum value displayed in the
MaxPD credit window at the remote end of the ATM interface. Otherwise, the rate at which switched calls can be set and released may be degraded.
On the ATM IISP Interface Configuration window, the maximum credit window (the SSCOP Rx Window Size field) is configurable with a value up to 32 for all ATM interfaces on the PSAX system. The interfaces of the ATM switches that are connected to the PSAX system should be configured with the same values. This method results in 100 percent call completion at a call setup rate of 60 calls per second using even distribution. If these values are not configured in this way, calls will be set up at a rate of less than 60 calls per second.
Note:
Various SSCOP parameter settings determine the maximum credit window. As a result, you may not be able to directly use these settings.
For more information on the SSCOP parameter, see the Application Note entitled Connecting a CBX or GX Switch to a PacketStar
®
PSAX Multiservice Media
Gateway via an ATM Port.
DSP Tone Detection Modes
DSP tone detection modes are selected through the Circuit Emulation-to-
ATM VCC PVC Connection
window
. These modes are described in Table B-1.
Table B-1. DSP Tone Detection Modes
*
and Associated Processing Performed
Tone Mode
Disabled
Bypass
Fax Relay
Fax Relay/Modem
Bypass
Processing Performed
Ignores fax tones and modem tones
If a fax tone or modem tone is received, the firmware switches to G.711 mode
(64 Kbps) and bypasses echo cancellation, if enough bandwidth is available.
If a fax tone is received, the firmware switches to a channel configured for
FaxRelayMode and performs fax demodulation / remodulation. If a modem tone is received, the firmware ignores it
If a fax tone is received, the firmware switches to a channel configured for
FaxRelayMode and performs fax demodulation/remodulation. If a modem tone is received, the firmware switches to G.711 mode (64 Kbps) and bypasses echo cancellation, if enough bandwidth is available.
*
Modes selected on the
Circuit Emulation-to-ATM VCC PVC Connection
window.
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
B-2
Release 10.0.0
255-700-576
Appendix B Reference Information
Connection Type by Interface Type
Connection Type by Interface Type
The PacketStar
®
PSAX Multiservice Media Gateway provide a number of connection types and interface types to the network as described in Table B-2.
Configuring interfaces and connections are described in the PacketStar
®
PSAX
Connections Provisioning Guide that can be found on the PacketStar
®
PSAX Mul-
tiservice Media Gateways Product Information Library CD-ROM.
Table B-2. Connection Type by Interface Type
Interface Type
Connection Type
AAL2 PVC Trunk
AAL2 Channel PVC VCC Connection
*
X X X X X X
X X X X X X
ATM-to-ATM virtual channel connection (VCC)
PVC
X X X X X X
X X X X ATM-to-ATM virtual path connection (VPC)
PVC
Bridge-to-ATM VCC PVC
Bridge-to-bridge PVC
X X X X X X X
X X X X X X
X
Circuit emulation-to ATM VCC PVC
Circuit emulation-to circuit emulation PVC
CPU Ethernet Bridge PVC
Frame relay-to-ATM VCC PVC
Frame relay-to-frame relay PVC
GR-303-to-AAL2 VCC PVC
†
X X X X X X
X X X X X X
In-band management ATM PVC
Variable bit rate (VBR)-to-ATM VCC PVC
VBR-to-VBR PVC
In-Band Management SVC
X X X X X X
X X X X X X
X X X X X X
ATM-to-ATM VCC SPVC
ATM-to-ATM VPC SPVC
Circuit emulation-to-ATM VCC SPVC
CE-to-ATM Std AAL2 VCC SPVC
X X X X X X
X X X X X
X X X X
X X X X X X
Enhanced Router Module to ATM VCC SPVC
Frame relay-ATM VCC SPVC
VBR-to-ATM VCC SPVC
VBR-to-ATM Std AAL2 VCC SPVC
X X X X X
X X X X
X X X X X
X X X X X
X X X X X
X
X
X
X
X
X
X
X
‡
X
X
X
X
X
X
X
X
X
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
255-700-576
Release 10.0.0
B-3
Appendix B Reference Information
Interface Type by I/O Module Type
†
‡
*
An AAL2 PVC Trunk must be configured before an AAL2 Channel PVC connection can be created.
This connection also requires the use of 2-Port OC-3c/STM-1 Enhanced ATM
modules for both ends of the connection.
AAL2 PVCs must be configured before GR-303 connections can be configured.
A GR-303 Interface Group (IG) must be configured before GR-303 connections can be configured.
Interface Type by I/O Module Type
Table B-3 shows the available interface types for each PacketStar PSAX I/O module used in the PacketStar
®
PSAX Multiservice Media Gateway. This table does not include other PSAX modules that are not I/O modules, which include: the Alarm module, the DSP2x modules, the Enhanced Router module, the Route Server module, and the Tones and Announcements Server module
.
Table B-3. Interface Type by I/O Module Type
Interface
Module
6-Port DS1 IMA
6-Port Enhanced DS1/T1
Multiservice
12-Port Medium-Density
DS1 Multiservice
12-Port Medium-Density
DS1 IMA
X
X
X X
DS1/T1 Interface Modules
X X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
12-Port Medium-Density
DS1/E1/DS0A CES
24-Port High-Density DS1
Multiservice
8-Port HDSL-2
X X X X
X
X
*
X
X
†
X
X
X
‡
X
X
X
X X X X X
DS3, E3, and STS-1e Interface Modules
X X X X X X X X X X
§
1-Port Channelized DS3
Multiservice
1-Port DS3 IMA
X X X X X
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
B-4
Release 10.0.0
255-700-576
Table B-3. Interface Type by I/O Module Type (Continued)
Appendix B Reference Information
Interface Type by I/O Module Type
Interface
Module
1-Port Unchannelized DS3
Frame Relay
1-Port Channelized STS-1e,
T1 Format
X
2-Port DS3 ATM
2-Port E3 ATM
3-Port Channelized
DS3/STS-1e CES
3-Port Channelized
DS3/STS-1e CES Protection
3-Port Channelized
DS3/STS-1e Multiservice
Protection
X
X
3-Port DS3/E3 ATM
3-Port DS3/E3 ATM
Protection
3-Port Unstructured
DS3/E3 CES
3-Port Unstructured
DS3/E3 CES Protection
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
E1 Interface Modules
X X X X X
X X X X
6-Port E1 IMA
6-Port Enhanced E1
Multiservice
21-Port High-Density E1
Multiservice
21-Port High-Density E1
IMA
X
X X
X
X
X
X
X
X
Ethernet
4-Port Ethernet
Ethernet Interface Modules
X
X
X
X X
X X
X
X
X
X
X X
X X X
X X X
X
X
X
X
X
X
X
X
X
X
X
X
X
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
255-700-576
Release 10.0.0
B-5
Appendix B Reference Information
Interface Type by I/O Module Type
Table B-3. Interface Type by I/O Module Type (Continued)
Interface
Module
1-Port Channelized
OC-3/STM-1 CES
Multimode
1-Port Channelized
OC-3/STM-1 CES Singlemode
1-Port Channelized
OC-3/STM-1 Unstructured
CES/ATM Single-Mode
X
¶
1-Port Channelized OC-
3/STM-1 Unstructured
CES/ATM Multimode
X
¶
2-Port OC-3c/STM-1 ATM
Multimode
2-Port OC-3c/STM-1 ATM
Single-Mode
4-Port OC-3c/STM-1
Multimode
4-Port OC-3c/STM-1
Single-Mode
X
X
X
X
1-Port OC-3c 1+1 APS
Multimode
1-Port OC-3c 1+1 APS
Single-Mode
1-Port STM-1 1+1 MSP
Multimode
1-Port STM-1 1+1 MSP
Single-Mode
1-Port OC-12c/STM-4c
Multimode
1-Port OC-12c/STM-4c
Single-Mode
2-Port OC-3c/STM-1
Enhanced ATM Multimode
X
X
X
X
X
X
X
Fiber-Optic Interface Modules
X
X
X
X
X
X
X
X
X
X
X
X
X
¶
¶
X
X
X
X
X
X
X
X
X
X
X
X
X
¶
¶
X
X
X
X
X
X
X
X
X
X
X
X
X
¶
¶
X
X
X
X
X
X
X
X
X
**
X
**
X
X
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
B-6
X
X
Release 10.0.0
255-700-576
Table B-3. Interface Type by I/O Module Type (Continued)
Appendix B Reference Information
Minimum AAL2 Trunk Size Requirements Tables
Interface
Module
2-Port OC-3c/STM-1
Enhanced ATM Single-
Mode
X X X X
Quadserial
6-Port Multiserial
X
Serial Interface Modules
X X X
X X
Voice 2-Wire Interface Modules
X
X
X
X
X
X
X
X
4-Port Voice 2-Wire Office
8-Port Voice 2-Wire Station
X
††
X
††
¶
**
††
‡
§
*
†
The module supports CAS Trunkline in DS1 and E1 modes only.
The module supports Circuit Emulation in DS1, E1, and DS0A modes.
The module supports GR-303 in DS1 mode only.
The module supports PRI ISDN in DS1 and E1 modes only.
The module supports ATM services in the STM-ATM mode only.
The module supports CE in the OC3-UCE mode only.
European modules do not support this interface with the 8-Port Voice 2-Wire Station module or the 4-Port Voice 2-Wire Office module.
Minimum AAL2 Trunk Size Requirements Tables
Setting up channels with standard AAL2 multiplexing helps reduce traffic delay, as voice samples from at two channels or more are multiplexed into one VC, decreasing the amount of time necessary to fill one ATM cell before it is transmitted. (Without multiplexing, only one VC is allowed per ATM cell.
The cell must wait to fill with samples from one channel before transmission). If a trunk is configured to have at least one active channel, one cell must be sent out every 20 ms; thus, the minimum trunk size is 50 cps. At
8 Kbps, Lucent recommends two multiplexed channels. On the DSP2C module, you can configure up to 64 AAL2 trunk groups, so that if you want to use all 128 channels (or 224 for echo cancel mode), you must use multiplexing. Enabling silence detection further enhances bandwidth savings by a factor of approximately half on the value in the cells/sec column in Table B-4.
Table B-4 summarizes bandwidth savings at different compression rates with standard AAL2 multiplexing.
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
255-700-576
Release 10.0.0
B-7
Appendix B Reference Information
Minimum AAL2 Trunk Size Requirements Tables
Table B-4. Standard (Multiplexed) AAL2 Bandwidth Calculation
*
Compression
Rate (in Kbps)
Data
Bytes
/sec
64 8000
40 5000
32
24
4000
3000
16
8
2000
1000
Data + Overhead
Calculation
(8000/40)*43
(5000/25)*28
(4000/20)*23
(3000/15)*18
(2000/10)*13
(1000/5/2)*13
Data +
Overhead
/sec
8600
5600
4600
3600
2600
1300
Cells/sec calculation
8600/47
5600/47
4600/47
3600/47
2600/47
1300/47
Cells
/sec
183
120
98
77
56
28
Average
Expected cells/sec with silence detection enabled
92
60
49
39
28
14
*
If a trunk has at least one active channel, a cell must be sent out every 20 msec; therefore, the minimum
AAL2 trunk size is 50 cps.
Standard AAL2 Calculation Example
The following calculation computes the compression rate for 32 Kbps (see
Table B-4). This calculation includes the AAL2 header in cells per second
(cps):
4,000 samples / 20 samples received from DSP * 23 bytes to be packed into an AAL2 cell, where 23 bytes = 20 bytes of data in the cps packet and 3 bytes for the cps header.
With 47 data bytes in the AAL2 cell, the cell rate = 4600/47 =~ 98
The expected cell rate with silence detection is: 98/2 = 49.
See Table B-5 for the cell rates for Lucent nonmultiplexed AAL2.
Table B-5. Non-Multiplexed AAL2 Transmission Rates
Compression Rate (in Kbps)
64
40
32
24
16
8
Cell/sec
200
200
100
100
50
25
Fax Relay Using AAL2 Requirements
Table B-6 shows the cell rate for fax relay modulation/demodulation using
Algosets 4 or 6 on the DSP2C or DSP2D Voice Server modules.
• Changing rates of 8 Kbps to 14.4 Kbps fax requires an additional 14 cells/sec.
• Changing rates of 8 Kbps to 12.0 Kbps fax requires an additional 8 cells/sec.
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
B-8
Release 10.0.0
255-700-576
Appendix B Reference Information
Module Alarm Status Descriptions
• Changing rates of 8 Kbps to 9.6 Kbps fax requires an additional 1 cell/sec.
Fax relay mode contains 20 msec of data for every cps packet, so the cell rate is more efficient than for voice codec.
The change in bandwidth is controlled by the DSP host code. If insufficient bandwidth is available on the AAL2 trunk, the fax will be forced to a lower rate. DSP resources must be available or the fax will fail. In addition, fax modem bypass or fax relay/modem bypass is supported if enough bandwidth is available on the AAL2 trunk.
Table B-6. Standard AAL2 Bandwidth Calculation for Fax Relay Mode Using DSP AlgoSets 4 or 6
Compression
Rate (in Kbps)
14.4
12.0
9.6
Data
Bytes
/sec
1800
1500
1200
Data + Overhead
Calculation
1800/(36*39)
1500/(30*33)
1200/(24*27)
Data +
Overhead
/sec
1950
1650
1350
Cells/sec calculation
1950/47
1850/47
1350
Cells
/sec
42
36
29
Average
Expected cells/sec with silence enabled
N/A
N/A
N/A
Module Alarm Status Descriptions
The Alarm Status field on the Equipment Configuration window is described in Table B-7.
Table B-7. Module Alarm Status Descriptions on the Equipment Configuration Window
Alarm Status
NoAlarm
WrongCardType
LineFailed
Hexadecimal format,
Example:
12345678ABC
CardRemoved
Module Type
Affected
Description
I/O and Server Indicates that no alarms have been detected for the module in this slot.
I/O and Server Indicates that one type of module was configured in this slot in the chassis, but a now different module occupies this slot.
All Indicates that the module in this slot is no longer receiving or transmitting signals because the line failed.
I/O and Server Indicates that one or more ports on the module in this slot currently have a loss of signal. The numbers indicate which ports have a loss of signal. For modules that have more than eight ports not receiving signals, the value in this field is in hexadecimal format.
All Indicates that one of the following events occurred:
• The module in this slot was configured and then removed from the slot.
• Connections on the OC-3, OC-12, STM-1, or STM-4
APS/MSP primary module in this slot were transferred to the standby module. After the transfer occurs, the former primary module then displays CardRemoved in the
Alarm Status field; the former standby module then displays Primary in the Status field.
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
255-700-576
Release 10.0.0
B-9
Appendix B Reference Information
ATM Service Categories in the PSAX System
Table B-7. Module Alarm Status Descriptions on the Equipment Configuration Window (Continued)
Alarm Status
Module Type
Affected
ReferenceClockFailed Stratum 3–4
Description
CompositeClockFailed Stratum 3–4
Indicates that the timing reference clock on the Stratum module in this slot failed.
Indicates that the timing composite clock on the Stratum module in this slot failed.
Overload Power Supply Indicates that the Power Supply module is operating under an overload condition.
Power Supply Indicates that the power has failed.
PowerFailed
Minus48vFailed Power Supply Indicates that the -48 V dc Power Supply module output failed.
UnknownAlarm I/O and Server Indicates that the reason for failure is not known.
CompleteClockFailed Stratum 3–4 Indicates that the backplane detected a clock error.
PowerFailed Power Supply Indicates that no power is coming into the PSAX chassis.
ATM Service Categories in the PSAX System
ATM Service Category Description
The PSAX system support of defined ATM quality of service (QoS) categories is described in Table B-8.
Table B-8. PSAX System-Supported Quality of Service Categories
ATM Service Category Description
Constant Bit Rate (CBR) This service offers consistent delay predictability. CBR is used for applications such as circuit emulation, voice, and video.
Real Time Variable Bit
Rate (VBR-rt)
Non-Real Time Variable
Bit Rate (VBR-nrt)
This service offers low delay variance, but requires access to a variable amount of network bandwidth. VBR-rt is used for applications such as packet video and voice.
This service allows delay variance between the delivery of cells. VBR-nrt is used for data applications that have potentially bursty traffic characteristics.
Guaranteed Frame Rate
(GFR)
This service allows delay variance and offers a minimum cell rate guarantee. When used with frame-based data encapsulated in AAL5 PDUs, it provides frame-based cell discard. GFR is used for frame relay or ethernet over ATM.
Unspecified Bit Rate
(UBR)
This service allows for best-effort transport by the network. Cells are transported by the network whenever bandwidth is available and the user presents traffic.
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
B-10
Release 10.0.0
255-700-576
Appendix B Reference Information
ATM Service Categories in the PSAX System
Priority of ATM Service Categories in the PSAX System
The attributes of the categories of service supported by the PSAX system software are identified in Table B-9. The service examples in this table are intended simply as illustrations; you should choose your service category based on your network applications supported by the PSAX system. The flexibility of the PSAX system allows you to tailor the system based on the required service applications by selecting the appropriate connection configuration selection field value.
Table B-9. Mapping ATM Service Categories to PSAX System Priority Levels
ATM Service Category
Constant Bit Rate (CBR)
Connection
Configuration
Field Value
AQueMan Priority
(Legacy
Implementation)
ATM Forum Traffic
Management 4.1
Priority (Current
Implementation)
CBR1
CBR2
Highest
Lower than
CBR1
Highest
CBR3
Real Time Variable Bit
Rate (VBR-rt)
CBR4
VBR-express
VBR-rt1
Lower than
CBR2
Lower than
CBR3
Lower than
CBR4
Lower than
VBR-express
Lower than CBR
Non-Real Time Variable
Bit Rate (VBR-nrt)
Guaranteed Frame Rate
(GFR)
Unspecified Bit Rate
(UBR)
VBR-rt2
VBR-nrt1
VBR-nrt2
GFR2
UBR
Lower than
VBR-rt1
Lower than
VBR-rt2
Lower than
VBR-nrt1
Lowest (shares queue with UBR)
Lowest
Lower than
VBR-rt
Lower than
VBR-nrt
Lowest
Service Examples
911 calls
Preferred customers
Standard
Cellular
Network management
Real-time video
MPEG 1-2/JPEG
Data
Data
Frame relay,
Ethernet, TCP
UDP
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
255-700-576
Release 10.0.0
B-11
Appendix B Reference Information
ATM Service Categories in the PSAX System
PacketStar
®
PSAX 12-Port Medium-Density DS1/E1/DS0A CES Module User Guide (E1 Mode), Issue 1
B-12
Release 10.0.0
255-700-576
Copyright © 2004 Lucent Technologies
All rights reserved.
Part Number: 565M0A10001D1