Lucent Technologies PSAX 20N32 Voice 2-Wire Office Module User Guide
PDF
Dokumentti
Mainos
Mainos
PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide Model 20N32 for the PacketStar® PSAX Multiservice Media Gateways Issue 1, December 2004 System Software Release 10.0.0 Navis® EMS-PSAX Software Release 10.0.0 Doc. No.: 255-700-596 Copyright © 2004 by Lucent Technologies. All rights reserved. For trademark, regulatory compliance, and related legal information, see the "Legal Notices, Safety, and Regulatory Information" section. Legal Notices, Safety, and Regulatory Information Copyright Copyright © 2004 by Lucent Technologies. All rights reserved. This material is protected by the copyright laws of the United States and other countries. It may not be reproduced, distributed, or altered in any fashion by any entity (either internal or external to Lucent Technologies), except in accordance with applicable agreements, contracts or licensing, without the express written consent of the originating organization and the business management owner of the material. Trademarks PacketStar, Lucent, Lucent Technologies, and the Lucent Technologies logo are registered trademarks of Lucent Technologies in the USA. Other product and brand names mentioned in this guide are trademarks or registered trademarks of their respective owners. Notices The information in this document is for informational use only, is subject to change without notice, and should not be construed as a commitment by Lucent Technologies, Inc. This document is without warranty of any kind, either expressed or implied. Lucent Technologies, Inc. assumes no responsibility for any errors, inaccuracies, or omissions. Neither is any liability assumed for damages resulting from the use of the information or instructions contained herein. Lucent Technologies, Inc. is not responsible for any damage or loss to your data or equipment resulting either directly or indirectly from use of this document. Warranty Information Software and Hardware Limited Warranties Lucent Technologies provides a 90-day limited software warranty, and a oneyear limited hardware warranty on this product. Refer to the Software License and Limited Warranty Agreement and the Lucent Technologies InterNetworking Systems Global Warranty that accompanied your package for more information. PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 255-700-596 Release 10.0.0 iii Legal Notices, Safety, and Regulatory Information Safety Information Warranty Warnings ! WARNING: When inserting modules into the chassis, slide them gently, not forcefully. Excessive force may cause the modules to be seated improperly in the chassis, and result in possible damage to the module or the chassis. Install or remove modules one at a time. Doing this aids in preventing the PSAX system from indicating any erroneous failure messages, and allows the PSAX system time to reinitialize and display the accurate configuration of the module that is inserted. ! CAUTION: Modifying or tampering with PSAX chassis components may void your warranty. Any modification to this equipment not expressly authorized by Lucent Technologies may void your granted authority to operate such equipment. ! CAUTION: Shipping the chassis with removable I/O, server, or CPU modules installed may cause damage to the chassis and the modules. Damage to any of the components in the system resulting from shipping the chassis with removable modules installed will void your warranty. ! DANGER: Interface lines connected to the 4-Port Voice 2-Wire Office module (model 20N32) that exit the building premises must be connected to telecommunication devices that provide primary and secondary protection. Safety Information When installing and operating the 4-Port Voice 2-Wire Office module, follow the safety guidelines provided in the PacketStar®PSAX Multiservice Media Gateway Safety Guidelines, which accompanies this product, to help prevent serious personal injury and damage to the module. Please read all warnings and instructions supplied before beginning installation or configuration of this module. In addition to the general safety information provided, you should also refer to the appropriate PSAX installation guide for other important safety information and procedures. When installing and operating the modules, follow the safety guidelines provided in the PacketStar®PSAX Multiservice Media Gateway Safety Guidelines, which accompanies this product, to help prevent serious personal injury and damage to the modules. Please read all warnings and instructions supplied before beginning installation or configuration of this module. PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 iv Release 10.0.0 255-700-596 Legal Notices, Safety, and Regulatory Information Regulatory Standards Compliance Regulatory Standards Compliance Safety and Electromagnetic Compatibility (EMC) The following PacketStar PSAX systems are compliant with applicable safety and EMC standards when configured with the 4-Port Voice 2-Wire Office module (model 20N32): The following PacketStar PSAX systems are compliant with applicable safety and EMC standards when configured with both the 20N32 modules, respectively: • PSAX 1000 system • PSAX 1250 system • PSAX 2300 system • PSAX 4500 system Refer to the PacketStar PSAX 1000, PSAX 1250, PSAX 2300, or PSAX 4500 installation guide for details on safety and EMC standards compliance. Telecommunications • FCC Part 68 (USA) • CS-03 Issue 8 (Canada) Regulatory Statements USA Regulatory Statements FCC Part 68 This equipment complies with Part 68 of the FCC rules. On the back of the PSAX chassis is a label that contains the FCC registration number, in addition to other information. You must provide this information to the telephone company, if they request it. The FCC requires Lucent Technologies to provide you with the following information: 1. This equipment has digital service interface capabilities using RJ-48C and RJ-48H connectors. The facility interface codes with which this equipment complies for digital services are as follows: 04DU9-BN, 04DU9-DN, 04DU9-1KN, and 04DU9-1SN. This equipment has loop start interface capabilities using an RJ-11C connector. The facility interface code with which this equipment complies for service is 02LS2. The service order codes for this equipment are 6.0F for the T1 interface and 9.0Y for the loop start interface. 2. An FCC-compliant telephone network interface jack is built into this equipment and is compatible with interconnections that are Part 68 compliant. 3. The REN for the 4-Port Voice 2-Wire Office module when used in this equipment is 0.7B. 4. If this equipment causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service might be required. But if advance notice is not practical, the tele- PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 255-700-596 Release 10.0.0 v Legal Notices, Safety, and Regulatory Information Regulatory Statements phone company will notify you as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe this is necessary. 5. The telephone company might make changes in its facilities, equipment, operations, or procedures that could affect the operation of this equipment. If this happens, the telephone company will provide advance notice for you to make necessary modifications to maintain uninterrupted service. 6. If you experience trouble with this equipment, or need repairs or warranty information, please refer to the Lucent Technologies InterNetworking Systems Global Warranty that accompanied your PSAX product shipment for instructions on obtaining technical support in your area. If this equipment is causing harm to the telephone network, the telephone company might request that you disconnect the equipment until the problem is resolved. 7. This equipment has no user-serviceable parts. This equipment cannot be used on public coin telephone service provided by the telephone company. Connection to party line service is subject to state tariffs. Contact your state public utility commission, public service commission, or corporation commission for information. Canadian Regulatory Statements CS-03 Issue 8 NOTICE: This equipment meets applicable Industry Canada Terminal Equipment Technical Specifications. This is confirmed by the registration number. The abbreviation, IC, before the registration number signifies that registration was performed based on a Declaration of Conformity indicating that Industry Canada technical specifications were met. It does not imply that Industry Canada approved the equipment. The Ringer Equivalence Number (REN) assigned to the 4-Port Voice 2-Wire Office module denotes the percentage of the total load to be connected to a telephone loop, which is used by the device, to prevent overloading. The termination on a loop may consist of any combination of devices subject only to the requirement that the total of the REN of all devices does not exceed 5. The REN for the 4-Port Voice 2-Wire Office module when used in the PSAX system is 0.7B. SH-03 Version 8 AVIS: Le présent matériel est conforme aux spécifications techniques d’Industrie Canada applicables au matériel terminal. Cette conformité est confirmée par le numéro d’enregistrement. Le sigle, IC, placé devant le numéro d’enregistrement, signifie que l’enregistrement s’est effectué conformément à une déclaration de conformité et indique que les spécifications techniques d’Industrie Canada ont été respectées. Il n’implique pas qu’Industrie Canada a approuvé le matériel. PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 vi Release 10.0.0 255-700-596 Legal Notices, Safety, and Regulatory Information Regulatory Statements Le nombre équivalent de sonnerie (REN) attribué au module central bifilaire (Voice 2-Wire Office) correspond au pourcentage de la charge totale à connecter à un circuit téléphonique bifilaire; il est utilisé par l’appareil pour prévenir la surcharge. Le circuit peut être terminé par n’importe quelle combinaison d’appareils, à la seule condition que le total des REN de ces derniers ne dépasse pas cinq. Lorsqu’il est utilisé dans le système PSAX, le module central bifilaire possède un REN de 0,7 B. PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 255-700-596 Release 10.0.0 vii Legal Notices, Safety, and Regulatory Information Regulatory Statements PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 viii Release 10.0.0 255-700-596 Contents Legal Notices, Safety, and Regulatory Information . . . . . . . . . . . . . . . . . iii Copyright . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii Trademarks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii Warranty Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii Software and Hardware Limited Warranties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii Warranty Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..iv iv Regulatory Standards Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v Safety and Electromagnetic Compatibility (EMC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v Telecommunications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v Regulatory Statements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v USA Regulatory Statements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v FCC Part 68 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v Canadian Regulatory Statements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi CS-03 Issue 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi SH-03 Version 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi List of Figures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xii List of Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii 1 Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 1-1 Purpose of This Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1 Audience for This Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1 What You Should Know . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1 Related Reading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2 Product Information Library . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2 Printed Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2 Other Publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2 About Lucent Technologies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2 About the PacketStar PSAX Product Family . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2 PSAX 1000 Multiservice Media Gateway. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-3 PSAX 1250 Multiservice Media Gateway. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-3 PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 255-700-596 Release 10.0.0 ix Contents PSAX 2300 Multiservice Media Gateway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 PSAX 4500 Multiservice Media Gateway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 Document Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 Text Types Used in This Document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 Icons and Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 Use of Command Description Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 Use of Field Description Tables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 General Document Navigational Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7 Selecting Options, Fields, and Commands Using the Console Interface . . . . . . . . . . . 1-7 Help Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8 Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9 Before You Begin. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10 Comments on This Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10 2 Module Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 Overview of This Chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 4-Port Voice 2-Wire Office Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2 Module Placement Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2 Hardware Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2 General Hardware Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2 Power Consumption and Memory Allocation Specifications . . . . . . . . . . . . . . . . . . . . . . . 2-3 LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 Connector Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4 3 Configuring Ports and Channels Using the Console Interface . . . . . . . . . . . 3-1 Overview of This Chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 Before You Begin. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 Using the Equipment Configuration Window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 Accessing the Equipment Configuration Window . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 Alarm Status Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6 Configuring the Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7 Saving the Equipment Configuration and Logging Off . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13 Errors When Applying Interfaces to Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-15 Provisioning Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-15 A Reference Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 Overview of This Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 DSP Tone Detection Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 Connection Type by Interface Type Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 x Release 10.0.0 255-700-596 Contents Interface Type by Input/Output Module Type Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-3 Module Alarm Status Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-6 4-Port Voice 2-Wire Office Module Line Status Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-7 ATM Service Categories in the PSAX System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-8 ATM Service Category Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-8 Priority of ATM Service Categories in the PSAX System . . . . . . . . . . . . . . . . . . . . . . . A-8 Module Cable for the 4-Port Voice 2-Wire Office Module . . . . . . . . . . . . . . . . . . . . . . . . A-9 PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 255-700-596 Release 10.0.0 xi List of Figures 1-1 Field Description Table Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-6 1-2 Main Menu Help Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-9 2-1 4-Port Voice 2-Wire Office Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-1 3-1 Sample Equipment Configuration Window on a PSAX 1000 System (Page 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-2 3-2 Sample Equipment Configuration Window on a PSAX 1250 System (Page 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-3 3-3 Sample Equipment Configuration Window on a PSAX 2300 or PSAX 4500 System (Page 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-3 3-4 Sample Equipment Configuration Window on a PSAX 1000, PSAX 2300, or PSAX 4500 System (Page 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4 3-5 Sample Equipment Configuration Window on a PSAX 1250 System (Page 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4 3-6 Console Interface Main Menu (Equipment Configuration Selected) . . . . . . . . . . . . . . . . . . . . .3-8 3-7 Equipment Configuration Window (As Displayed on the PSAX 1000, PSAX 1250, PSAX 2300, and PSAX 4500 Console) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-9 3-8 Two Wire Office Configuration Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-9 3-9 Two Wire Office Port and Channel Configuration Window . . . . . . . . . . . . . . . . . . . . . . . . . .3-11 3-10 Save Configuration [Modified] (Before Saving) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-14 PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 255-700-596 Release 10.0.0 xii List of Tables 1-1 Text Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-5 1-2 Command Description Table Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-6 1-3 System Responses to Selecting Options, Fields, or Commands . . . . . . . . . . . . . . . . . . . . . . . .1-7 1-4 Shortcut Keys for Navigating Console Interface Windows . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-8 2-1 Physical Hardware Specifications for the PSAX I/O Module . . . . . . . . . . . . . . . . . . . . . . . . . . .2-2 2-2 Performance and Power Specifications for the PSAX Module . . . . . . . . . . . . . . . . . . . . . . . . .2-3 2-3 LED Indicators for the 4-Port Voice 2-Wire Office Module . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-4 3-1 Equipment Configuration Window Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-5 3-2 Equipment Configuration Window Field Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-5 3-3 Module Alarm Status Descriptions on the Equipment Configuration Window . . . . . . . . . . . . .3-7 3-4 Two Wire Station Configuration Window Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-10 3-5 Voice Two Wire Office Port and Channel Configuration Window Commands . . . . . . . . . . . .3-11 3-6 Two Wire Office Port and Channel Configuration Window Field Descriptions . . . . . . . . . . . .3-12 3-7 Messages Generated after the Save Configuration Process . . . . . . . . . . . . . . . . . . . . . . . . . .3-15 A-1 DSP Tone Detection Modes and Associated Processing Performed . . . . . . . . . . . . . . . . . . . . A-1 A-2 Connection Type by Interface Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2 A-3 Interface Type by I/O Module Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-3 A-4 Module Alarm Status Descriptions on the Equipment Configuration Window . . . . . . . . . . . . A-6 A-5 4-Port Voice 2-Wire Office and 8-Port Voice 2-Wire Station Line Status Codes . . . . . . . . . . . A-7 A-6 PSAX System-Supported Quality of Service Categories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-8 A-7 Mapping ATM Service Categories to PSAX System Priority Levels . . . . . . . . . . . . . . . . . . . . . A-9 A-8 Orderable I/O and Common Equipment Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-9 PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 255-700-596 Release 10.0.0 xiii List of Tables PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 xiv255-700-596 Release 10.0.0 1 Getting Started Purpose of This Guide The PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide provides a description of the 4-Port Voice 2-Wire Office module. It also provides information on how to configure the module ports and channels. For information on configuring interfaces and provisioning connections through the PSAX console interface, see the PacketStar® PSAX Connections Provisioning Guide. If the Navis® EMS-PSAX interface is being used, see the Navis® EMS-PSAX Interface and Connection Provisioning Guide. Note: If you are using this module for the first time, you should read through this guide in its entirety before beginning the configuration process. The chapters in this guide are arranged in the logical order of normal configuration and should be performed in that order for the module to operate successfully. Audience for This Guide The information in this guide is intended for users who will configure ports and channels for the 4-Port Voice 2-Wire Office module in the PSAX Multiservice Media Gateway system. What You Should Know Before you use this document or operate a PSAX system, you should already understand and have experience with the following: • ATM Forum, Frame Relay Forum, and other telecommunications specifications • Ethernet network capabilities • Internet Protocol capabilities • Data network design • Telephony network design PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 255-700-596 Release 10.0.0 1-1 Chapter 1 Getting Started Related Reading Related Reading Product Information Library To install, operate, and configure your PSAX system and I/O and server modules, read the PSAX publications provided on your Lucent Technologies PacketStar® PSAX Multiservice Media Gateways Product Information Library CD-ROM. Printed Documents For your convenience, many of the documents included on the PacketStar® PSAX Multiservice Media Gateways Product Information Library CD-ROM are also available in printed form. You can order these documents through the Lucent Technologies Customer Information Center Web site at: http://www.lucentdocs.com. Other Publications Numerous books are currently available on the subject of basic telecommunications technology and specific protocols. In addition to such general reading, you should also be familiar with the industry specifications identified in this guide. About Lucent Technologies Lucent Technologies is the communications systems and technology company formed through the restructuring of AT&T. We bring with us a tradition of more than 125 years of experience and a dedication to superior customer service. Lucent Technologies manufactures, sells, and services a complete line of customer premises communications units, and commercial and multimedia communications and messaging systems designed and supported by our research and development unit, Bell Laboratories. Our legacy and our spirit of innovation allow Lucent to provide our customers with the tools needed to communicate effectively, any time and anywhere, and to integrate the latest technologies into real-life solutions that help make business work. About the PacketStar PSAX Product Family Lucent Technologies provides a complete range of PSAX Multiservice Media Gateways in the PacketStar PSAX family. PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 1-2 Release 10.0.0 255-700-596 Chapter 1 Getting Started About the PacketStar PSAX Product Family PSAX 1000 Multiservice Media Gateway The PacketStar PSAX 1000 Multiservice Media Gateway is designed to provide a full range of central office-based multiservice media gateway functions in a small, competitively-priced package suitable for customer premise deployment. Ideal for central office, large enterprise, or wireless cell site multiservice media gateway applications, the PSAX 1000 system provides highly reliable network access for time-division multiplex voice, frame relay, 10/100BASE-T Ethernet, and ATM data applications. When it is functioning in a redundant operating mode and after it has experienced a single-point failure, the PSAX 1000 system provides up to 630 Mbps of ATM cell bus capacity. The total ATM cell bus capacity of the system may also be scaled to provide nonblocking, nonredundant chassis bandwidths beyond 630 Mbps. Supporting up to five slots (19–inch chassis) for I/O and server modules—with a full range of interfaces such as DS0A, DS1/E1, DS3/E3, OC-3, OC-3c/STM-1, OC-12c/STM-4c, 10/100BASE-T Ethernet, and serial—the PSAX 1000 system is a cost-effective access switch solution for connecting to legacy equipment. PSAX 1250 Multiservice Media Gateway The PacketStar PSAX 1250 Multiservice Media Gateway is designed to provide a full range of central office-based multiservice ATM access functions. Ideal for the central office or a large enterprise’s multiservice media gateway, the PSAX 1250 system provides highly reliable network access for time-division multiplex voice, frame relay, 10/100BASE-T Ethernet, and ATM data applications. When it is functioning in a redundant operating mode and after it has experienced a single-point failure, the PSAX 1250 system provides up to 600 Mbps of ATM cell bus capacity. The total ATM cell bus capacity of the system may also be scaled to provide nonblocking, nonredundant chassis bandwidths beyond 600 Mbps. Supporting 10 slots (19-inch chassis) or 14 slots (23-inch chassis) for I/O and server modules—with a full range of interfaces such as DS0A, DS1/E1, DS3/E3, OC-3, OC-3c/STM-1, OC-12c/STM-4c, 10/100BASE-T Ethernet, and serial—the PSAX 1250 system is a cost-effective access switch solution for interworking with legacy equipment. PSAX 2300 Multiservice Media Gateway The PacketStar PSAX 2300 Multiservice Media Gateway offers carrier-grade, high-density multiservice ATM access functions. Designed as the multiservice media gateway for the central office or for a large enterprise customer, the PSAX 2300 system provides network access for time-division multiplex voice, frame relay, 10/100BASE-T Ethernet, and ATM data applications. PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 255-700-596 Release 10.0.0 1-3 Chapter 1 Getting Started About the PacketStar PSAX Product Family When it is functioning in a redundant operating mode and after it has experienced a single-point failure, the PSAX 2300 system provides up to 1.9 Gbps of ATM cell bus capacity. The total ATM cell bus capacity of the system may also be scaled to provide nonblocking, nonredundant chassis bandwidths beyond 1.9 Gbps. Supporting 15 slots for I/O and server modules—with provisions for OC-3, OC-3c/STM-1, and OC-12c/STM-4c interfaces with 1:1 protection, 1:1 DS1 module protection switching, and a full range of interfaces such as DS0A, DS1/E1, DS3/E3, 10/100BASE-T Ethernet, and serial—the PSAX 2300 system solves demanding and diverse network design challenges with ease. PSAX 4500 Multiservice Media Gateway The PacketStar PSAX 4500 Multiservice Media Gateway provides carrier-class reliability, with an unmatched range of service capabilities, end-to-end traffic prioritization, “any-service, any-channel” flexibility, and breakthrough voice technology. Ideal for the central office or a large enterprise multiservice media gateway, the PSAX 4500 system provides highly reliable network access for time-division multiplex voice, frame relay, 10/100BASE-T Ethernet, and ATM data applications. When it is functioning in a redundant operating mode and after it has experienced a single-point failure, the PSAX 4500 system provides up to 4.2 Gbps of ATM cell bus capacity. The total ATM cell bus capacity of the system may also be scaled to provide nonblocking, nonredundant chassis bandwidths beyond 4.2 Gbps. The high-performance midplane design supports 15 interface slots. Module protection for two groups of four or six multiport DS3, STS-1e, or E3 modules is provided via an N:1 protection scheme using rear access line interface modules. The protection module provides backup so that on the failure of any one of the modules in a group, traffic is maintained. A single PSAX 4500 system at the edge of the carrier network can transition traffic from a large number of network customers over high-speed DS1/E1 IMA, DS3/E3, OC-3, OC-3c/STM-4c, and OC-12c/STM-4c trunks into the ATM core, managing the whole quickly and efficiently, down to the individual permanent virtual circuit. Through the use of the latest DSP voice technology, the PSAX 4500 system supports advanced voice traffic over ATM (VToA) services for up to 6048 DS0 channels. As a multiservice media gateway—with H.248 call control, CAS, PRI, GR-303, and V5.2 protocols, 3-Port DS3/STS-1e, 1-Port OC-3/STM-1 CES, and Tones and Announcements modules—the PSAX 4500 system provides packet solutions for voice over xDSL, trunking, tandem, and PRI offload switching. PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 1-4 Release 10.0.0 255-700-596 Chapter 1 Getting Started Document Conventions Document Conventions Text Types Used in This Document This guide uses a different typeface to denote text displayed on console interface windows and equipment, as well as data you enter. Table 1-1 shows how each typographical convention is used. Table 1-1. Text Conventions Appearance How it is used SANS SERIF BOLD, ALL CAPS Labels on module panels, chassis faceplates, or other hardware Fixed-width normal Message text displayed on the user interface window Serif bold • Button name (GUI interface) or command name (console interface) on the user interface window • Literal text for values that the user types or selects from predefined sets of values for fields • Commands or literal argument values Fixed-width bold System prompts displayed on the user interface window Serif italics • A variable name or string for which you will substitute your own information • An argument or parameter on a command line for which you will substitute your own information Icons and Symbols Refer to the procedures within this guide for important safety information and proper procedures. Standard icons and symbols to alert you to dangers, warnings, cautions, and notes are described as follows: ! DANGER: Warnings for a personal injury hazard are identified by this format. ! WARNING: Warnings relating to risk of equipment damage or failure are identified by this format. ! CAUTION: Warnings relating to risk of data loss or other general precautionary notes are identified by this format. Note: Identifies additional information pertinent to the text preceding this note. PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 255-700-596 Release 10.0.0 1-5 Chapter 1 Getting Started Document Conventions Use of Command Description Tables All illustrations for configuration windows in this guide for the PSAX system console interface are followed by a command description table describing the command functions displayed on the window (near the bottom of the window). You should read all the information in the command description table, especially when first using a window, because these descriptions may have special instructions or configuration constraints provided in the Function column by use of the Note: text convention (see Table 1-2). Table 1-2. Command Description Table Example Command Function Bring All Interfaces Brings the out-of-service configured interfaces to in-service status. Into Service Note: In GR-303 configuration, it is critical to bring into service only those channels actively configured with DS1 ports. Use of Field Description Tables For all illustrations for configuration windows in this guide for both the PSAX system console interface and the EMS-PSAX, the field description tables normally follow the command description tables. Field description tables define the editable and the display-only fields, their functions, valid values, and constraints, if applicable. As in the command description tables, the Note: text convention is also used, where appropriate, in the field description tables to alert the user to special instructions or configuration constraints (see Figure 1-1). Identifies editable fields or display-only fields on screens Identifies initial field value default Field Name Field Values Interface Type Identifies available range for field value when applicable Default: 0 Range: 0-22 Format: Numeric Describes the function of the field and special instructions for configuring modules Description Specifies the type of end-to-end connection protocol that governs the transmission parameters for this configured port and channel interface. Note: When certain types of interfaces are selected in this field, other configuration fields are displayed on this window. Identifies field value format as Numeric, Predefined Alphanumeric, Hexadecimal, or Valid Dotted Quad. Decribes special instructions or configuration constraints Figure 1-1. Field Description Table Example PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 1-6 Release 10.0.0 255-700-596 Chapter 1 Getting Started General Document Navigational Guidelines General Document Navigational Guidelines Selecting Options, Fields, and Commands Using the Console Interface Follow these guidelines to select an option, field, or command on the PSAX console interface windows and to navigate through the windows: • To select an option, field, or command, do one of the following: ~ Press the Up, Down, Left, or Right Arrow to highlight (reverse video image) the option name, field name, or command you want to select and press Enter as many times as necessary until the field choice you want is displayed. ~ Use the alternate keys, K=UP, H=LEFT, L=RIGHT to highlight (reverse video image) the option name, field name, or command you want to select and press Enter. (You can optionally redefine these alternate keys from the User Options window, which is accessible from the Console Interface Main Menu window.) ~ To quickly select a command, you can also simultaneously press Ctrl and the letter underlined in the command. Once an option name, field, or command is selected, the system responds as described in Table 1-3. Table 1-3. System Responses to Selecting Options, Fields, or Commands For a selected... the following occurs: option name The window corresponding to the option name is displayed. field The following variations occur: • The field entry area is blank or contains the default or previously entered value. Press Enter to enter or change data in this field. Press Enter again to exit edit mode. • The field entry area, like the field name, is displayed in reverse video image and contains a predefined set of values, which you can view or select by pressing Enter to navigate forward through these values. To navigate backward through these field values, press Ctrl+H or the Backspace key. Read-only fields, which you cannot change, are enclosed in square brackets (example: [LineStatus]). command The following variations occur: • A message in the information line indicating an error or successful completion of the command is displayed. • The next higher level or previous window (window name) is displayed. • The next lower level or succeeding window (window name) is displayed. • To navigate through the Console windows, use the shortcuts listed in Table 1-4. PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 255-700-596 Release 10.0.0 1-7 Chapter 1 Getting Started Help Information Table 1-4. Shortcut Keys for Navigating Console Interface Windows If you want to... press... redisplay the previous window Ctrl+B on the window. redisplay the Console Interface Main Menu window Ctrl+G on the window. refresh the window Ctrl+R on the window. On all the PSAX system windows, each command or menu option has an underlined letter. The control key plus an underlined letter is a shortcut to that command or menu option. You can use the navigation keys and hotkeys with the Caps Lock key on or off. Always observe the status line at the bottom of the window for instructions and information. Help Information The Help windows are accessible from any window in the PSAX system console interface. To access the Help windows, press the ? (Question Mark) key on any window. In addition to the Help windows, the Console Interface windows display contextual help in the information line at the bottom of each window. Contextual help provides information about the command or field currently highlighted on that window. The information line also displays error codes and responses to commands. All responses and notifications are recorded in a trap log. See the PacketStar® PSAX Simple Network Management Protocol (SNMP) Trap Reference Guide for details on displaying the trap log and obtaining explanations of the trap messages. To view the Help windows from the Console Interface Main Menu window, perform the following procedure. Begin 1 On the window for which help is desired, press the ? (question mark) key. The Help window for the current console window is displayed (see Figure 1-2). PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 1-8 Release 10.0.0 255-700-596 Chapter 1 Getting Started Technical Support Your site name appears here after initial configuration Information Line Figure 1-2. Main Menu Help Window 2 To display the remaining Help windows for the current console window, press the Down Arrow key. 3 To scroll backward through the Help windows for the current console window, press the Up Arrow key. 4 To exit Help and return to the current console window, press the Enter key. End Technical Support If you experience a problem with the 4-Port Voice 2-Wire Office module, refer to the Lucent Technologies Product Warranty Registration Information, which accompanied your shipment, for instructions on obtaining support in your area. PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 255-700-596 Release 10.0.0 1-9 Chapter 1 Getting Started Before You Begin Before You Begin Before you start configuring and using your new 4-Port Voice 2-Wire Office module, be sure you: • Record your site-specific specifications such as the IP addresses you will use, and the connections and interfaces you will need. Decide which user names and passwords you will assign. • Make sure you have IP connectivity to all PSAX devices to be managed • Determine the numbering scheme for any in-band management connections you will be using Comments on This Guide To comment on the PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, please complete the comment card at the following web address: http://www.lucent-info.com/comments/ You can also email your comments to [email protected]. Include the following information: Title: PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide Release number: Release 10.0.0 Document number: 255-700-596 Issue number: Issue 1 Publication date: December 2004 PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 1-10 Release 10.0.0 255-700-596 2 Module Description Overview of This Chapter The 4-Port Voice 2-Wire Office module provides support for the office (central office or PABX switch) end of a two-wire analog telephone line. This allows a voice loop from a voice switch to be connected directly to a Multiservice Media Gateway system over an ATM network to a distant telephone or other analog device. The coding translation supported by this module is µ-law to µ-law only. The module has three LED indicators: ACTIVE, FAIL, and off-hook (labeled 1-4). On the faceplate, each port has an LED which illuminates when the port goes off-hook. It also flashes in synchronization with an incoming ringing signal to the port. 1 FAIL ACTIVE VOICE 2WO 1 2 3 4 Figure 2-1. 4-Port Voice 2-Wire Office Module PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 255-700-596 Release 10.0.0 2-1 Chapter 2 Module Description 4-Port Voice 2-Wire Office Module 4-Port Voice 2-Wire Office Module This module is typically configured with an 8-Port Voice 2-Wire Station module via a PVC connection to enable a foreign exchange (FXO) voice service to be transmitted across an ATM network. With FXO service, the voice switch provides dial tone, ringing, and digit translation, which are not provided by the ATM network. Module Placement Requirements The 4-Port Voice 2-Wire Office module may be installed in any I/O slot of any PSAX Multiservice Media Gateway chassis intended to contain I/O or server modules. In typical applications, this module is used with the 8-Port Voice 2Wire Station module (see the appropriate PSAX module user guide for other configuration constraints). Hardware Features The 4-Port Voice 2-Wire Office module supports these hardware features: • Number of ports: 4 • Connector type: shielded RJ-12 • Ring frequency detection: 16-32 Hz • Termination impedance: 600 Ohms • Signaling: dual tone multi-frequency (DTMF) • Supervision: loop start General Hardware Specifications Table 2-1 provides the general physical hardware and environmental specifications for the PSAX I/O module. Table 2-1. Physical Hardware Specifications for the PSAX I/O Module Specification Description Dimensions 17.3 cm H x 2.41 cm W x 24.1 cm D (6.8 in. H x 0.95 in. W x 9.5 in. D) Weight 0.37 kg (0.82 lb.) Operating temperature range for all the 0° to 50° C (32° to 122° F) PSAX 1250, PSAX 2300, and PSAX 4500 systems Operating temperature range for the PSAX 1000 systems For AC-powered PSAX 1000 systems: 0° to 50° C (32° to 122° F) For DC-powered PSAX 1000 systems: -20° to 60° C (-4° to 140° F) with a cold start minimum of 0° C (32° F) PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 2-2 Release 10.0.0 255-700-596 Chapter 2 Module Description Power Consumption and Memory Allocation Specifications Table 2-1. Physical Hardware Specifications for the PSAX I/O Module (Continued) Specification Description Operating humidity range for all chassis 5% to 85% relative humidity Operating altitude range for all chassis 60 meters (197 feet) below sea level to 4,000 meters (13,123 feet) above sea level Storage temperature range for all chassis -40° to 70° C (-40° to 158° F) Storage humidity range for all chassis 0% to 90% noncondensing Additional information can be found in the appropriate PacketStar PSAX module user guides. Power Consumption and Memory Allocation Specifications Table 2-2 provides the chassis speed, power consumption, and memory allocation specifications for this PSAX module. Table 2-2. Performance and Power Specifications for the PSAX Module Module 20N32 4-Port Voice 2-Wire Office Total Amount of SDRAM 8 MB Module Maximum Program and Input Data Space Buffer 4 MB N/A Output Buffer Chassis Speed N/A Low Speed Maximum Power Consumption 14 W LED Indicators Table 2-3 describes how the LED indicators on the 4-Port Voice 2-Wire Office module respond to different module conditions. These LEDs indicate if the module has been installed properly. Before you configure the module, you must ensure that it is properly initialized according to the information provided in Table 2-3. PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 255-700-596 Release 10.0.0 2-3 Chapter 2 Module Description Connector Pin Assignments Table 2-3. LED Indicators for the 4-Port Voice 2-Wire Office Module Module Status LED Initial Power-On No Configured Ports One or More Configured Ports No Cable on Port Cable on Port FAIL (red) Lights briefly* Not lit Lights only when the module is not functioning Not Applicable Not Applicable ACTIVE (green) Lights briefly* Not lit Lights only when Not Applithe module is func- cable tioning properly Not Applicable 1–4 (green) Each lights Not Applibriefly cable Not Applicable Flashing LED indicates the line is ringing. Solid LED indicates the line is off-hook (in use) or busy. Unilluminated LED indicates the line is on-hook (not in use). * Not Applicable After power is initially applied to the system and the system boot is complete, the FAIL and ACTIVE LEDs indicate whether the module has no configured ports (red), or one or more configured ports (green). Connector Pin Assignments The four shielded RJ-12 connectors provide a 2-wire analog interface on pins 3 (ring) and 4 (tip). Shielded cabling is required between the module and CO equipment. PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 2-4 Release 10.0.0 255-700-596 3 Configuring Ports and Channels Using the Console Interface Overview of This Chapter This chapter describes how to use the console interface to perform the following tasks on the 4-Port Voice 2-Wire Office module: • Obtaining general module data and accessing ports and channels • Setting the values for the port and channel configuration of the module Before You Begin Be sure to complete the following tasks first before configuring the 4-Port Voice 2-Wire Office module: • Configure your basic system (see “Configuring the System for Your Site” in the PacketStar® PSAX Multiservice Media Gateway User Guide). • Configure the Stratum 3–4 module (see “Configuring the Stratum 3–4 Module” in the PacketStar® PSAX Multiservice Media Gateway User Guide). When configuring the 4-Port Voice 2-Wire Office module using the console interface, display-only fields are displayed in square brackets ([ ]). ! CAUTION: Due to the copper wire interface between an Enhanced DS1 or E1 module and a PBX and/or key telephone system, the PSAX system and the other equipment should use a common chassis ground connection to avoid ground current loops, which could affect voice quality. Using the Equipment Configuration Window This section describes how to obtain product, model, version, and serial number data about a module from the Equipment Configuration window. In addition, the window provides operational status and alarm conditions on each installed module. You also use this window to access the port and channel configuration windows for the PSAX modules. Accessing the Equipment Configuration Window Perform the following procedure to access the Equipment Configuration window. PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 255-700-596 Release 10.0.0 3-1 Chapter 3 Configuring Ports and Channels Using the Console Interface Using the Equipment Configuration Window Begin 1 On the Console Interface Main Menu window, select the Equipment Configuration option. The Equipment Configuration window is displayed (see Figure 3-1 through Figure 3-5). 2 View the operational and alarm status, software version, PEC, and serial number data of the installed modules. 3 When you are ready to begin configuring the ports and channels of the module, select the line displaying the name of the module you want to configure. 4 Proceed to the section, “Configuring the Ports,” for module configuration procedures. Note: The sample Equipment Configuration windows in the following figures may not show the actual module you are configuring. These figures illustrate the variations of slot configurations for the different PSAX chassis displayed on the Equipment Configuration window. End Figure 3-1. Sample Equipment Configuration Window on a PSAX 1000 System (Page 1) PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 3-2 Release 10.0.0 255-700-596 Chapter 3 Configuring Ports and Channels Using the Console Interface Using the Equipment Configuration Window Figure 3-2. Sample Equipment Configuration Window on a PSAX 1250 System (Page 1) Figure 3-3. Sample Equipment Configuration Window on a PSAX 2300 or PSAX 4500 System (Page 1) PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 255-700-596 Release 10.0.0 3-3 Chapter 3 Configuring Ports and Channels Using the Console Interface Using the Equipment Configuration Window Figure 3-4. Sample Equipment Configuration Window on a PSAX 1000, PSAX 2300, or PSAX 4500 System (Page 2) Figure 3-5. Sample Equipment Configuration Window on a PSAX 1250 System (Page 2) Commands The commands in this window have the following functions. PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 3-4 Release 10.0.0 255-700-596 Chapter 3 Configuring Ports and Channels Using the Console Interface Using the Equipment Configuration Window Table 3-1. Equipment Configuration Window Commands Update Display Refreshes the current status of the modules in the PSAX chassis. Page Down Displays the second page of the Equipment Configuration window. This command toggles with Page Up. Page Up Displays the first page of the Equipment Configuration window. This command toggles with Page Down. Interface by Name Displays the Interface Name Table window on which you can view all the interface names in the PSAX system. Go Back to Main Menu Redisplays the Console Interface Main Menu window. Field Description The display-only fields on this window are described in Table 3-2. Table 3-2. Equipment Configuration Window Field Descriptions Slot Default: N/A Displays the slot number in the PSAX chassis. Range: 1–25, depends on chassis type Format: Numeric Module Type Default: N/A Range: N/A Format: Predefined Displays the type of the module in the slot. When a module is inserted into the chassis, its name is displayed in the Module Type field next to the slot number. When the module is removed from the chassis, its name is no longer displayed in the Module Type field and is replaced with None. Status Default: Unknown Range: N/A Format: Predefined Displays the operational status of the module. Unknown Indicates that the module has not been configured. Primary Indicates one of the following: • at least one port or channel on an I/O module has been configured. • a CPU module is functioning as the primary CPU module. Standby Indicates one of the following: • a module in redundant systems is operating as the standby (backup) module to the primary (active) module. • a CPU module in redundant systems is functioning as the standby (backup) CPU module. Default: No Alarm Range: N/A Format: Predefined Displays the present alarm condition of the module. Alarm Status PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 255-700-596 Release 10.0.0 3-5 Chapter 3 Configuring Ports and Channels Using the Console Interface Using the Equipment Configuration Window Table 3-2. Equipment Configuration Window Field Descriptions (Continued) SW # Default: N/A Range: N/A Format: Predefined Displays the version of PSAX system software with which the modules’ firmware was released. The software version is encoded in the module firmware. Because not all modules require firmware upgrades with every new PSAX system software release, the software version that is displayed in this window may be lower than the CPU system software that is currently running on the PSAX system. See the most recent Release Note document for the latest software and firmware lineup information. PEC Default: N/A Range: N/A Format: Predefined Displays the product element code (PEC) used to identify and order this type of module. The PEC is encoded in the module bootloader. Serial # Default: N/A Range: N/A Format: Predefined Displays the unique serial number of the individual module. The product serial number is encoded in the module firmware. The format of this field is the following: PSAX System Rel. 6.5.0 and later: 12-digit number in the format: YYVVDDnnnnnn, where YY = year of manufacture VV = vendor ID code (manufacturer and location) DD = date code of manufacture (either month or week depending on vendor’s preference) nnnnnn = sequential number, which in conjunction with YY, VV, and DD, creates a unique number for each hardware component in the PSAX product line For existing products with the 10-digit serial number used in Rel. 6.5.0 or later systems, this number is displayed with two preceding zeros. PSAX Rel. 6.3.0 and earlier: 10-digit number. For products with 12-digit serial numbers used in Rel 6.3.0 or earlier systems, the first two digits (YY) are not displayed. Alarm Status Values The Alarm Status field on the Equipment Configuration window is described in . PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 3-6 Release 10.0.0 255-700-596 Chapter 3 Configuring Ports and Channels Using the Console Interface Configuring the Ports Table 3-3. Module Alarm Status Descriptions on the Equipment Configuration Window Alarm Status Module Type Affected Description NoAlarm I/O and Server Indicates that no alarms have been detected for the module in this slot. WrongCardType I/O and Server Indicates that one type of module was configured in this slot in the chassis, but a now different module occupies this slot. LineFailed All Hexadecimal format, Example: 12345678ABC I/O and Server Indicates that one or more ports on the module in this slot currently have a loss of signal. The numbers indicate which ports have a loss of signal. For modules that have more than eight ports not receiving signals, the value in this field is in hexadecimal format. CardRemoved All Indicates that the module in this slot is no longer receiving or transmitting signals because the line failed. Indicates that one of the following events occurred: • The module in this slot was configured and then removed from the slot. • Connections on the OC-3, OC-12, STM-1, or STM-4 APS/MSP primary module in this slot were transferred to the standby module. After the transfer occurs, the former primary module then displays CardRemoved in the Alarm Status field; the former standby module then displays Primary in the Status field. ReferenceClockFailed Stratum 3–4 Indicates that the timing reference clock on the Stratum module in this slot failed. CompositeClockFailed Stratum 3–4 Indicates that the timing composite clock on the Stratum module in this slot failed. Overload Power Supply Indicates that the Power Supply module is operating under an overload condition. PowerFailed Power Supply Indicates that the power has failed. Minus48vFailed Power Supply Indicates that the -48 V dc Power Supply module output failed. UnknownAlarm I/O and Server Indicates that the reason for failure is not known. CompleteClockFailed Stratum 3–4 Indicates that the backplane detected a clock error. PowerFailed Indicates that no power is coming into the PSAX chassis. Power Supply Configuring the Ports To configure the 4-Port Voice 2-Wire Office module ports, follow the following procedure. PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 255-700-596 Release 10.0.0 3-7 Chapter 3 Configuring Ports and Channels Using the Console Interface Configuring the Ports Configuring the Ports Begin 1 On the Console Interface Main Menu window (see Figure 3-6), select the Equipment Configuration option and press Enter. Figure 3-6. Console Interface Main Menu (Equipment Configuration Selected) The Equipment Configuration window (see Figure 3-7) is displayed. PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 3-8 Release 10.0.0 255-700-596 Chapter 3 Configuring Ports and Channels Using the Console Interface Configuring the Ports Figure 3-7. Equipment Configuration Window (As Displayed on the PSAX 1000, PSAX 1250, PSAX 2300, and PSAX 4500 Console) 2 On the Equipment Configuration window, select the 4-Port Voice 2-Wire Office module and press Enter. The Two Wire Office Configuration window is displayed (see Figure 3-8). Figure 3-8. Two Wire Office Configuration Window Commands Table 3-4 describes the commands on this window: PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 255-700-596 Release 10.0.0 3-9 Chapter 3 Configuring Ports and Channels Using the Console Interface Configuring the Ports Table 3-4. Two Wire Station Configuration Window Commands Update Display Updates the values in the fields to show the most current configuration. Use this command mostly to display the most current information in the Line Status field. Configure All Interfaces Sets all four ports to the circuit emulation type interface. The value CircuitEmulation is displayed in the Interface Type field, and the value OutOfService is displayed in the Oper Status field. Delete All Interfaces Deletes the configured interfaces for all four ports. The value Unconfigured is displayed in the Interface Type and the Oper Status fields. Note: You must first take all interfaces out of service (using the Take All Interfaces Out Of Service command) before you can use this command to delete all the configured interfaces. Bring All Interfaces Into Service Brings the out-of-service configured interfaces for all four ports to in-service status. The value InService is displayed in the Oper Status field for all four ports. Take All Interfaces Out Of Service Takes the in-service configured interfaces for all four ports to out-of-service status. The value OutOfService is displayed in the Oper Status field for all four ports. Note: You must use this command first before using the Delete All Interfaces command. Go Back to Equipment Con- Redisplays the Equipment Configuration window. figuration 3 To configure the ports, do one of the following: a. If you want to configure all four ports with the default port field values given in Table 3-6, select the Configure All Interfaces command and press Enter. The value CircuitEmulation is displayed in the Interface Type field, and the value OutOfService is displayed in the Oper Status field. b. To configure one port at a time (to set values other than the default ones), select the line for the port you want to configure and press Enter. The Two Wire Office Port and Channel Configuration window (see Figure 3-9) is displayed. PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 3-10 Release 10.0.0 255-700-596 Chapter 3 Configuring Ports and Channels Using the Console Interface Configuring the Ports Figure 3-9. Two Wire Office Port and Channel Configuration Window Commands Table 3-5 describes the commands on this window: Table 3-5. Voice Two Wire Office Port and Channel Configuration Window Commands Apply Port and Channel Configuration Applies the configuration field values you set. Reset Port and Channel Display Resets the fields to the last set of saved values. Bring Interface Into Service Brings an out-of-service configured interface to in-service status. This command is displayed when the [Oper Status] field is OutOfService. The value InService is displayed in the [Oper Status] field. When this command is executed, the Take Interface Out of Service command is displayed instead. Take Interface Out of Service Takes an in-service configured interface to out-of-service status. Command is displayed when the [Oper Status] field is InService. The value OutOfService is displayed in the [Oper Status] field. Configure Interface Displays the Circuit Emulation Interface Configuration window. Enter to Card Configuration Redisplays the Two Wire Office Configuration window. 4 Select the values for the fields on this window from the values given in Table 3-6. PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 255-700-596 Release 10.0.0 3-11 Chapter 3 Configuring Ports and Channels Using the Console Interface Configuring the Ports Table 3-6. Two Wire Office Port and Channel Configuration Window Field Descriptions Test Mode Default: Off Range: N/A Format: Predefined Specifies the test mode of the module. Off The module is not in test mode. QuietTime Quiet Time is useful only if the line is not quiet enough. If the line is noisy, the quiet time feature will help you to determine whether the channel is noisy. If noise is present on the line, then the channel is defective. Note: Do not select this value unless the line is noisy. F-1004Hz A 1004 Hz tone is used in troubleshooting a system where a line is seized by bridging the tip and ring wires through a resistance. [Signaling Bits] Ab Signaling bits method supported is AB (two-bit signaling). [Dial Mode] Dtmf Dual tone multi-frequency [Loop Detect] LoopStart Loop detection. [Line Status] Default: NoAlarm Range: N/A Format: Predefined Indicates the Line Status of the interface. It contains loopback, failure, received alarm and transmitted alarm information. For a line status message list, see the Reference Appendix in this guide. Interface Type Default: Unconfigured Range: N/A Format: Predefined Specifies whether the interface is assigned or not. Unconfigured This interface is not configured. Circuit Emulation This interface is configured for circuit emulation. Default: Unconfigured Range: N/A Format: Predefined Specifies whether the channel can pass traffic or not. Unconfigured This channel is not operational because the interface is not configured InService This channel is capable of receiving and sending signals. OutOfService This channel is not capable of receiving and sending signals. [Oper Status] PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 3-12 Release 10.0.0 255-700-596 Chapter 3 Configuring Ports and Channels Using the Console Interface Saving the Equipment Configuration and Logging Off Table 3-6. Two Wire Office Port and Channel Configuration Window Field Descriptions (Continued) [Silence Suppression] Default: Pvc Range: N/A Format: Predefined Permanent virtual circuit (PVC). [Echo Cancellation] Default: Disabled Range: N/A Format: Predefined Silence suppression is disabled. [Voice Compression] The echo cancellation function is disabled. This function is a method for isolating and filtering unwanted signal energy caused by echoes from the main transmitted signal. Disabled [Companding Law] Disabled Voice compression is disabled. [AAL Encapsulation] MuLawPCM The PCM coding and companding standard used in North America and Japan. [Silence Suppression] Aal1 ATM Adaptation Layer 1 (AAL1) [Service Type] Fxo Foreign exchange office (FXO) 5 To apply the values for the fields on this window, select the Apply Port and Channel Configuration command and press Enter. 6 Select the Configure Interface command and press Enter. The Circuit Emulation Interface Configuration window is displayed. Note: For information on configuring the Circuit Emulation interface using the AC console, see the PacketStar® PSAX Connections Provisioning Guide. 7 Repeat this procedure for the remainder of the ports, as needed. Note: Whenever needed, use the commands in the Two Wire Office Configuration window (see Figure 3-8 on page 3-9) and on the Two Wire Office Port and Channel Configuration window (see Figure 3-9 on page 3-11) to manage the interfaces. End Saving the Equipment Configuration and Logging Off After configuring the module ports and channels, the interface types for each port and channel, and the connections, you must save the values to the PSAX system database. It is recommended that you save your values frequently as you progress through your work, at a minimum, after finishing each stage of work: • Configuring each module in your system • Configuring the connections in your system PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 255-700-596 Release 10.0.0 3-13 Chapter 3 Configuring Ports and Channels Using the Console Interface Saving the Equipment Configuration and Logging Off • Before exiting your current console session Perform the following procedure to permanently save the values for your system. ! CAUTION: If your system loses power or if you reboot the chassis, and you have not yet saved the values permanently, you will lose all unsaved values you have applied on the various windows. Begin 1 Press Ctrl+G, to return to the Console Interface Main Menu window. On the Console Interface Main Menu window, [Modified] is displayed next to the Save Configuration command, indicating you have made changes to the system that are not yet saved to the PSAX system database (see Figure 3-10). Figure 3-10. Save Configuration [Modified] (Before Saving) 2 Select the Save Configuration command or press Ctrl+A. Wait a few seconds while the system writes the values to the PSAX system database. The system displays the following message while it is executing this command: Saving the equipment and connection information PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 3-14 Release 10.0.0 255-700-596 Chapter 3 Configuring Ports and Channels Using the Console Interface Errors When Applying Interfaces to Ports Note: In PSAX systems with redundant CPUn modules, the standby CPUn module reboots every time you save the configuration on the primary CPUn module. This event is a function of the SVC retention feature and the result of saving the configuration changes you have made. When the save configuration function is completed, the system displays an appropriate message as described in Table 3-7. Table 3-7. Messages Generated after the Save Configuration Process When a PSAX system is... the system displays... nonredundant T-SaveConfiguration: saveConfigurationReasonCode=All-OK redundant T-SaveConfiguration: saveConfigurationReasonCode = Expect2ndCPUCardFailedOrRemoved* The standby CPUn module is rebooted when the save command is issued. After the standby CPUn module reboots, the system displays the following message: T-SaveConfiguration: saveConfigurationReasonCode=FileTransferCompleted * This message indicates that while the standby CPUn module reboots after you select the Save Configuration command, the standby CPUn module is temporarily unavailable. After saving the configuration values, the indicator [Modified] is no longer displayed next to the Save Configuration command. End Errors When Applying Interfaces to Ports An error may occur when you apply an interface to a channel. If an error condition occurs, the PSAX system sends an SNMP trap that is usually displayed in the console Trap Log Display window (accessible from the Console Interface Main Menu window). The list below includes the most common interface errors that cause the PSAX system to display a message. (See the PacketStar® PSAX Simple Network Management Protocol (SNMP) Trap Reference Guide for more information about the SNMP traps related to interface errors). • Entering field values that are outside of the configurable range of values • Attempting to configure an interface for a port or channel that has already been configured • Attempting to configure an interface that is already in service (must be out of service to be configured or change field values) • Entering field values that are not recognized by the PSAX system software Provisioning Connections For instructions on configuring interfaces and connections to the 4-Port Voice 2-Wire Office module, see the PacketStar® PSAX Connections Provisioning Guide. PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 255-700-596 Release 10.0.0 3-15 Chapter 3 Configuring Ports and Channels Using the Console Interface Provisioning Connections The module supports the following type of interface: • Circuit Emulation The module supports the following types of connections: • PVC connections: ~ Circuit Emulation-to ATM virtual channel connection (VCC) ~ Circuit Emulation-to Circuit Emulation • SPVC connections: ~ Circuit Emulation-to-ATM VCC Before you provision connections for the modules, you must have first completed the following tasks: • Set the configuration values for one or more ports on the module • Set the configuration values for the various types of interfaces on the module PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 3-16 Release 10.0.0 255-700-596 A Reference Information Overview of This Appendix This appendix contains reference tables that are helpful while configuring your PSAX Multiservice Media Gateway system. The following types of information are provided: • DSP Tone Detection Settings • Connection Types by Interfaces Type Table • Interface Types by I/O Module Types Table • Module Alarm Status Table • 4-Port Voice 2-Wire Office Module Line Status Table • ATM Service Categories in the PSAX System • Module Cable for the 4-Port Voice 2-Wire Office Module DSP Tone Detection Settings DSP tone detection modes are selected through the Circuit Emulation-toATM VCC PVC Connection window. These modes are described in Table A-1. Table A-1. DSP Tone Detection Modes* and Associated Processing Performed Tone Mode Processing Performed Disabled Ignores fax tones and modem tones Bypass If a fax tone or modem tone is received, the firmware switches to G.711 mode (64 Kbps) and bypasses echo cancellation, if enough bandwidth is available. Fax Relay If a fax tone is received, the firmware switches to a channel configured for FaxRelayMode and performs fax demodulation / remodulation. If a modem tone is received, the firmware ignores it Fax Relay/Modem Bypass If a fax tone is received, the firmware switches to a channel configured for FaxRelayMode and performs fax demodulation/remodulation. If a modem tone is received, the firmware switches to G.711 mode (64 Kbps) and bypasses echo cancellation, if enough bandwidth is available. * Modes selected on the Circuit Emulation-to-ATM VCC PVC Connection window. Connection Type by Interface Type Table The PacketStar® PSAX Multiservice Media Gateways provide a number of connection types and interface types to the network as described in Table A-2. Configuring interfaces and connections are described in the PacketStar® PSAX Connections Provisioning Guide that can be found on the PacketStar® PSAX Multiservice Media Gateways Product Information Library CD-ROM. PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 255-700-596 Release 10.0.0 A-1 Appendix A Reference Information Connection Type by Interface Type Table AAL2 PVC Trunk X X X X X X AAL2 Channel PVC VCC Connection X X X X X X Terminal Emulation PRI ISDN (Network/User) HDLC Pass-through GR-303 Frame Relay (UNI, NNI) Circuit Emulation Bridge CAS TrunkLine ATM PNNI over VPC ATM UNI 3.0/3.1/4.0 ATM IMA ATM Virtual Interface Connection Type ATM PNNI 1.0 Interface Type ATM IISP (Network/User) Table A-2. Connection Type by Interface Type ATM-to-ATM virtual channel connection (VCC) X X X X X X PVC ATM-to-ATM virtual path connection (VPC) PVC X X X X Bridge-to-ATM VCC PVC X X X X X X X Bridge-to-bridge PVC X Circuit emulation-to ATM VCC PVC X X X X X X X Circuit emulation-to circuit emulation PVC X CPU Ethernet Bridge PVC X X X X X X Frame relay-to-ATM VCC PVC X X X X X X X Frame relay-to-frame relay PVC GR-303-to-AAL2 VCC PVC* X X† X X X X X X In-band management ATM PVC X X X X X X Variable bit rate (VBR)-to-ATM VCC PVC X X X X X X VBR-to-VBR PVC In-Band Management SVC X X X X X X ATM-to-ATM VCC SPVC X X X X X ATM-to-ATM VPC SPVC X X X Circuit emulation-to-ATM VCC SPVC X X X X X X X CE-to-ATM Std AAL2 VCC SPVC X X X X X X Enhanced Router Module to ATM VCC SPVC X Frame relay-ATM VCC SPVC X X X X X VBR-to-ATM VCC SPVC X X X X X VBR-to-ATM Std AAL2 VCC SPVC X X X X X * † X X X X X X X X X X X X X AAL2 PVCs must be configured before GR-303 connections can be configured. A GR-303 Interface Group (IG) must be configured before GR-303 connections can be configured. PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 A-2 X Release 10.0.0 255-700-596 Appendix A Reference Information Interface Type by Input/Output Module Type Table Interface Type by Input/Output Module Type Table Table A-3 shows the available interface types for each PacketStar PSAX I/O module used in the PacketStar® PSAX Multiservice Media Gateways. This table does not include other PSAX modules that are not I/O modules, which include: the Alarm module, the DSP2x modules, the Enhanced Router module, the Route Server module, and the Tones and Announcements Server module . X X X X X X X X X X X X X X X V5.2 X Terminal Emulation X Routing X PRI ISDN (Network/User) X HDLC Pass-through 12-Port Medium-Density DS1 IMA GR-303 X Frame Relay (UNI, NNI) X Circuit Emulation 12-Port Medium-Density DS1 Multiservice CAS Trunkline X Bridge X ATM Virtual Interface 6-Port Enhanced DS1/T1 Multiservice ATM UNI 3.0/3.1 X ATM UNI 4.0 X Module ATM PNNI over VPC ATM IMA 6-Port DS1 IMA Interface ATM PNNI 1.0 ATM IISP (Network/User) Table A-3. Interface Type by I/O Module Type DS1/T1 Interface Modules X X X X X* X† 12-Port Medium-Density DS1/E1/DS0A CES 24-Port High-Density DS1 Multiservice X X X X 8-Port HDSL-2 X X X X X X X‡ X X X§ X X X DS3, E3, and STS-1e Interface Modules 1-Port Channelized DS3 Multiservice X 1-Port DS3 IMA X X X X X X X X X X 1-Port Unchannelized DS3 Frame Relay X X X 1-Port Channelized STS-1e, T1 Format X X X X 2-Port DS3 ATM X X X X 2-Port E3 ATM X X X X 3-Port Channelized DS3/STS-1e CES PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 255-700-596 X X X X X X X X X X X Release 10.0.0 A-3 Appendix A Reference Information Interface Type by Input/Output Module Type Table 3-Port Channelized DS3/STS-1e Multiservice Protection X X V5.2 Terminal Emulation Routing PRI ISDN (Network/User) HDLC Pass-through X GR-303 X Frame Relay (UNI, NNI) Circuit Emulation 3-Port Channelized DS3/STS-1e CES Protection CAS Trunkline Bridge ATM Virtual Interface ATM UNI 3.0/3.1 ATM UNI 4.0 ATM PNNI 1.0 ATM PNNI over VPC Module ATM IMA Interface ATM IISP (Network/User) Table A-3. Interface Type by I/O Module Type (Continued) X X 3-Port DS3/E3 ATM X X X X X 3-Port DS3/E3 ATM Protection X X X X X 3-Port Unstructured DS3/E3 CES X 3-Port Unstructured DS3/E3 CES Protection X E1 Interface Modules 6-Port E1 IMA X 6-Port Enhanced E1 Multiservice X X X X X X X X X X X X X 21-Port High-Density E1 Multiservice X X X X X X X X X 21-Port High-Density E1 IMA X X X X X X Ethernet Interface Modules Ethernet X X 4-Port Ethernet X X Fiber-Optic Interface Modules 1-Port Channelized OC-3/STM-1 CES Multimode X X 1-Port Channelized OC-3/STM-1 CES Singlemode X X 1-Port Channelized X¶ OC-3/STM-1 Unstructured CES/ATM Single-Mode X¶ X¶ X¶ PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 A-4 X X** Release 10.0.0 255-700-596 Appendix A Reference Information Interface Type by Input/Output Module Type Table 1-Port Channelized OC3/STM-1 Unstructured CES/ATM Multimode X¶ X¶ X¶ X¶ 2-Port OC-3c/STM-1 ATM Multimode X X X X 2-Port OC-3c/STM-1 ATM Single-Mode X X X X 4-Port OC-3c/STM-1 Multimode X X X X 4-Port OC-3c/STM-1 Single-Mode X X X X 1-Port OC-3c 1+1 APS Multimode X X X X X 1-Port OC-3c 1+1 APS Single-Mode X X X X X 1-Port STM-1 1+1 MSP Multimode X X X X X 1-Port STM-1 1+1 MSP Single-Mode X X X X X 1-Port OC-12c/STM-4c Multimode X X X X X 1-Port OC-12c/STM-4c Single-Mode X X X X X 2-Port OC-3c/STM-1 Enhanced ATM Multimode X X X X 2-Port OC-3c/STM-1 Enhanced ATM SingleMode X X X X V5.2 Terminal Emulation Routing PRI ISDN (Network/User) HDLC Pass-through GR-303 Frame Relay (UNI, NNI) Circuit Emulation CAS Trunkline Bridge ATM Virtual Interface ATM UNI 3.0/3.1 ATM UNI 4.0 ATM PNNI 1.0 ATM PNNI over VPC Module ATM IMA Interface ATM IISP (Network/User) Table A-3. Interface Type by I/O Module Type (Continued) X** Serial Interface Modules Quadserial 6-Port Multiserial X X X X X X X X X X X X X X PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 255-700-596 Release 10.0.0 A-5 Appendix A Reference Information Module Alarm Status Table V5.2 Terminal Emulation Routing PRI ISDN (Network/User) HDLC Pass-through GR-303 Frame Relay (UNI, NNI) Circuit Emulation CAS Trunkline Bridge ATM Virtual Interface ATM UNI 3.0/3.1 ATM UNI 4.0 ATM PNNI over VPC Module ATM PNNI 1.0 Interface ATM IMA ATM IISP (Network/User) Table A-3. Interface Type by I/O Module Type (Continued) Voice 2-Wire Interface Modules 20N32 4-Port Voice 2-Wire Office X†† 8-Port Voice 2-Wire Station X†† * † ‡ § ¶ ** †† The module supports CAS Trunkline in DS1 and E1 modes only. The module supports Circuit Emulation in DS1, E1, and DS0A modes. The module supports GR-303 in DS1 mode only. The module supports PRI ISDN in DS1 and E1 modes only. The module supports ATM services in the STM-ATM mode only. The module supports CE in the OC3-UCE mode only. European modules do not support this interface with the 8-Port Voice 2-Wire Station module or the 4-Port Voice 2-Wire Office module. Module Alarm Status Table The Alarm Status field on the Equipment Configuration window is described in Table A-4. Table A-4. Module Alarm Status Descriptions on the Equipment Configuration Window Alarm Status Module Type Affected Description NoAlarm I/O and Server Indicates that no alarms have been detected for the module in this slot. WrongCardType I/O and Server Indicates that one type of module was configured in this slot in the chassis, but a now different module occupies this slot. LineFailed All Hexadecimal format, Example: 12345678ABC I/O and Server Indicates that one or more ports on the module in this slot currently have a loss of signal. The numbers indicate which ports have a loss of signal. For modules that have more than eight ports not receiving signals, the value in this field is in hexadecimal format. Indicates that the module in this slot is no longer receiving or transmitting signals because the line failed. PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 A-6 Release 10.0.0 255-700-596 Appendix A Reference Information 4-Port Voice 2-Wire Office Module Line Status Table Table A-4. Module Alarm Status Descriptions on the Equipment Configuration Window (Continued) Alarm Status CardRemoved Module Type Affected All Description Indicates that one of the following events occurred: • The module in this slot was configured and then removed from the slot. • Connections on the OC-3, OC-12, STM-1, or STM-4 APS/MSP primary module in this slot were transferred to the standby module. After the transfer occurs, the former primary module then displays CardRemoved in the Alarm Status field; the former standby module then displays Primary in the Status field. ReferenceClockFailed Stratum 3–4 Indicates that the timing reference clock on the Stratum module in this slot failed. CompositeClockFailed Stratum 3–4 Indicates that the timing composite clock on the Stratum module in this slot failed. Overload Power Supply Indicates that the Power Supply module is operating under an overload condition. PowerFailed Power Supply Indicates that the power has failed. Minus48vFailed Power Supply Indicates that the -48 V dc Power Supply module output failed. UnknownAlarm I/O and Server Indicates that the reason for failure is not known. CompleteClockFailed Stratum 3–4 Indicates that the backplane detected a clock error. PowerFailed Indicates that no power is coming into the PSAX chassis. Power Supply 4-Port Voice 2-Wire Office Module Line Status Table Table A-5. 4-Port Voice 2-Wire Office and 8-Port Voice 2-Wire Station Line Status Codes Bit Value Alarm Description 1 NoAlarm No alarm is present. 2 SignalingFailureState Signals failure state. 4 FacilityLoopBack Not currently supported. 8 Maintenance Maintenance. 16 Out Of Service Out of Service. 32 OtherFailure Any other line status not shown in this table. PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 255-700-596 Release 10.0.0 A-7 Appendix A Reference Information ATM Service Categories in the PSAX System ATM Service Categories in the PSAX System ATM Service Category Descriptions The PSAX system support of defined ATM quality of service (QoS) categories is described in Table A-6. Table A-6. PSAX System-Supported Quality of Service Categories ATM Service Category Description Constant Bit Rate (CBR) This service offers consistent delay predictability. CBR is used for applications such as circuit emulation, voice, and video. Real Time Variable Bit Rate (VBR-rt) This service offers low delay variance, but requires access to a variable amount of network bandwidth. VBR-rt is used for applications such as packet video and voice. Non-Real Time Variable This service allows delay variance between the delivery of cells. VBR-nrt Bit Rate (VBR-nrt) is used for data applications that have potentially bursty traffic characteristics. Guaranteed Frame Rate This service allows delay variance and offers a minimum cell rate guaran(GFR) tee. When used with frame-based data encapsulated in AAL5 PDUs, it provides frame-based cell discard. GFR is used for frame relay or ethernet over ATM. Unspecified Bit Rate (UBR) This service allows for best-effort transport by the network. Cells are transported by the network whenever bandwidth is available and the user presents traffic. Priority of ATM Service Categories in the PSAX System The attributes of the categories of service supported by the PSAX system software are identified in Table A-7. The service examples in this table are intended simply as illustrations; you should choose your service category based on your network applications supported by the PSAX system. The flexibility of the PSAX system allows you to tailor the system based on the required service applications by selecting the appropriate connection configuration selection field value. PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 A-8 Release 10.0.0 255-700-596 Appendix A Reference Information Module Cable for the 4-Port Voice 2-Wire Office Module Table A-7. Mapping ATM Service Categories to PSAX System Priority Levels ATM Service Category Constant Bit Rate (CBR) Connection AQueMan Priority Configuration (Legacy Field Value Implementation) ATM Forum Traffic Management 4.1 Priority (Current Implementation) Service Examples Highest 911 calls CBR1 Highest CBR2 Lower than CBR1 Preferred customers CBR3 Lower than CBR2 Standard CBR4 Lower than CBR3 Cellular VBR-express Lower than CBR4 VBR-rt1 Lower than VBR-express Real-time video VBR-rt2 Lower than VBR-rt1 MPEG 1-2/JPEG VBR-nrt1 Lower than VBR-rt2 VBR-nrt2 Lower than VBR-nrt1 Guaranteed Frame Rate (GFR) GFR2 Lowest (shares queue with UBR) Lower than VBR-nrt Frame relay, Ethernet, TCP Unspecified Bit Rate (UBR) UBR Lowest Lowest UDP Real Time Variable Bit Rate (VBR-rt) Non-Real Time Variable Bit Rate (VBR-nrt) Lower than CBR Network management Lower than VBR-rt Data Data Module Cable for the 4-Port Voice 2-Wire Office Module Table A-8. Orderable I/O and Common Equipment Cables COMCODE 300293586 Part No Description 42-02N00038 Shielded RJ-12 to RJ-12, Voice, 20N32 4-Port Voice 2-Wire Office 10 ft PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 255-700-596 Module Release 10.0.0 A-9 Appendix A Reference Information Module Cable for the 4-Port Voice 2-Wire Office Module PacketStar® PSAX 4-Port Voice 2-Wire Office Module User Guide, Issue 1 A-10 Release 10.0.0 255-700-596 Copyright © 2004 Lucent Technologies All rights reserved. Part Number: 528M0A10001D1 ">
/
Lataa
Ystävällinen muistutus. Voit tarkastella dokumenttia täällä. Mutta mikä tärkeintä, tekoälymme on jo lukenut sen. Se voi selittää monimutkaisia asioita yksinkertaisesti, vastata kysymyksiisi millä tahansa kielellä ja auttaa sinua navigoimaan nopeasti jopa pisimmissä tai monimutkaisimmissa dokumenteissa.
Mainos