Lucent Technologies PSAX 23N34 E1 IMA Module, PSAX 1000, 1250, 2300, 4500 Multiservice Media Gateway User Guide
PDF
Dokument
Werbung
Werbung
PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide Model 23N34 for the PacketStar® PSAX Multiservice Media Gateways Issue 1, December 2004 System Software Release 10.0.0 Doc. No.: 255-700-584 Copyright © 2004 by Lucent Technologies. All rights reserved. For trademark, regulatory compliance, and related legal information, see the "Legal Notices, Safety, and Regulatory Information" section. Legal Notices, Safety, and Regulatory Information Copyright Copyright © 2004 by Lucent Technologies. All rights reserved. This material is protected by the copyright laws of the United States and other countries. It may not be reproduced, distributed, or altered in any fashion by any entity (either internal or external to Lucent Technologies), except in accordance with applicable agreements, contracts or licensing, without the express written consent of the originating organization and the business management owner of the material. Trademarks PacketStar , Lucent, Lucent Technologies, and the Lucent Technologies logo are registered trademarks of Lucent Technologies in the USA. Other product and brand names mentioned in this guide are trademarks or registered trademarks of their respective owners. Notices The information in this document is for informational use only, is subject to change without notice, and should not be construed as a commitment by Lucent Technologies, Inc. This document is without warranty of any kind, either expressed or implied. Lucent Technologies, Inc. assumes no responsibility for any errors, inaccuracies, or omissions. Neither is any liability assumed for damages resulting from the use of the information or instructions contained herein. Lucent Technologies, Inc. is not responsible for any damage or loss to your data or equipment resulting either directly or indirectly from use of this document. Warranty Information Software and Hardware Limited Warranties Lucent Technologies provides a 90-day limited software warranty, and a oneyear limited hardware warranty on this product. Refer to the Software License and Limited Warranty Agreement and the Lucent Technologies InterNetworking Systems Global Warranty that accompanied your package for more information. PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Release 10.0.0 iii Warranty Warnings ! WARNING: When inserting modules into the chassis, slide them gently, not forcefully. Excessive force may cause the modules to be seated improperly in the chassis, and result in possible damage to the module or the chassis. Install or remove modules one at a time. Doing this aids in preventing the PSAX system from indicating any erroneous failure messages, and allows the PSAX system time to reinitialize and display the accurate configuration of the module that is inserted. ! CAUTION: Modifying or tampering with PSAX chassis components may void your warranty. Any modification to this equipment not expressly authorized by Lucent Technologies may void your granted authority to operate such equipment. ! CAUTION: Shipping the chassis with removable I/O, server, or CPU modules installed may cause damage to the chassis and the modules. Damage to any of the components in the system resulting from shipping the chassis with removable modules installed will void your warranty. Safety Warnings and Information When installing and operating the 21-Port High-Density E1 IMA module, follow the safety guidelines provided in the PacketStar®PSAX Multiservice Media Gateway Safety Guidelines, which accompanies this product, to help prevent serious personal injury and damage to the module. Please read all warnings and instructions supplied before beginning installation or configuration of this module. In addition to the general safety information provided, you should also refer to the appropriate PSAX installation guide for other important safety information and procedures. Regulatory Standards Compliance Safety and Electromagnetic Compatibility (EMC) The following PacketStar PSAX systems are compliant with applicable safety and EMC standards when configured with the 21-Port High-Density E1 IMA module (model 23N34): • PSAX 1000 system • PSAX 1250 system • PSAX 2300 system • PSAX 4500 system PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 iv Release 10.0.0 255-700-584 Refer to the PacketStar PSAX 1000, PSAX 1250, PSAX 2300, or PSAX 4500 installation guide for details on safety and EMC standards compliance. Telecommunications The 21-Port High-Density E1 IMA module (model 23N34) is compliant with the following applicable telecommunications standards: • ETSI TBR 12:1993+A1:1996 (Europe) • ETSI TBR 13:1996 (Europe) • TS 016:1997 (Australia) Regulatory Statements European Union Regulatory Statement CE Marking Hereby, Lucent Technologies declares that the PacketStar PSAX 1000 (-48 V dc and 220 V ac), PSAX 1250 (-48 V dc and 220 V ac), PSAX 2300, and PSAX 4500 Multiservice Media Gateways, including the equipment documented in this publication, are in compliance with the essential requirements and other relevant provisions of the following Council Directives: • Low Voltage 72/23/EEC • Electromagnetic Compatibility (EMC) 89/336/EEC • Radio Equipment and Telecommunications Terminal Equipment 1999/5/EC The Lucent PacketStar PSAX Multiservice Media Gateways deployed in the European Economic Area (EEA) are intended for connection to E1, E3, STM-1, and STM-4c networks. The EC Declarations of Conformity may be viewed or printed at the following public-access Internet site: http://www.lucentdocs.com/ins EU-regulativer CE-mærkning Lucent Technologies erklærer hermed at PacketStar PSAX 1000 (-48 V dc og 220 v vekselstrøm), PSAX 1250 (-48 V dc og 220 v vekselstrøm), PSAX 2300, og PSAX 4500 Multiservice Media Gateways, inkl. det udstyr der findes behandlet i denne dokumentation, er i overensstemmelse med følgende EUdirektiver: • Lavspændingsdirektivet 72/23/EEC • EMC-direktivet 89/336/EEC • Direktivet om radio og teleterminaludstyr 1999/5/EC Lucent PacketStar PSAX Multiservice Media Gateways, anvendt i EØS (Europæiske Økonomiske Samarbejde) skal forbindes med E1, E3, STM-1 og STM-4c netværk. EU-overensstemmelseserklæringen er at finde på følgende internetside hvorfra den også kan udskrives: http://www.lucentdocs.com/ins PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Release 10.0.0 v Behördliche Standard-CE-Kennzeichnung für die Europäische Gemeinschaft CE-Markierung Hiermit erklärt Lucent Technologies, dass die PacketStar PSAX 1000 (-48 V DC und 220 V~), PSAX 1250 (-48 V DC und 220 V~), PSAX 2300, und PSAX 4500 Multiservice Media Gateways, einschließlich den in dieser Publikation dokumentierten Anlagen, die notwendigen Anforderungen und anderen relevanten Vorschriften der folgenden Council-Direktiven einhalten: • Niederspannungsdirektive 72/23/EEC • Elektromagnetische Verträglichkeit (EMC) 89/336/EEC • Funkgeräte und Funkverkehr-Endeinrichtungen 1999/5/EC Die Lucent PacketStar PSAX Multiservice Media Gateways, die in der Europäischen Gemeinschaft im Einsatz stehen, dienen zum Anschluss an folgende Netztypen: E1, E3, STM-1 und STM-4c. Die Konformitätserklärung für die Europäische Gemeinschaft kann auf folgendem, öffentlich zugänglichem Internet-Site eingesehen oder ausgedruckt werden: http://www.lucentdocs.com/ins ¥²³²­·¸­¯¢q¶¢¸½´³¸¬»}½¶º´¥¿¯ »²º·¬» t Ä¥²·¬&( ©¸³´¥¶¢²¬/XFHQW7HFKQRORJLHV¨¬°µ²©­¢¸­¸¥3DFNHW6WDU PSAX1000 (-48 Vdc ¯¥­ 9DF), PSAX1250 (-48 Vdc¯¥­ 9DF), PSAX2300, ¯¥­PSAX Multiservice Media Gateways, ¯¥¹µ»¯¥­³©®³´°­·±¢»±©¸¥²¸½´¥¸¬»´¥¶³¤·¥» ¯¨³·¬»©²¥¶±³²¡¾³²¸¥­±©¸­»¦¥·­¯»¥´¥­¸ ·©­»¯¥­°³­´»·¼©¸­¯»¨­¥¸®©­»¸º² ¨¬«­µ²¸³½t½±¦³½°¡³½ • ¥±¬° ¸·¬(2. • +°©¯¸¶³±¥«²¬¸­¯ ·½±¦¥¸¢¸¬¸¥(0&(2. • ¥¨­³ªº²­¯¢» ©®³´°­·±¢» ¯¥­ }®³´°­·±¢» ¸©¶±¥¸­¯³¤ ¸¬°©´­¯³­²º²­µ² (. ¥/XFHQW3DFNHW6WDU36$;0XOWLVHUYLFH0HGLD*DWHZD\V´³½¼³½²¸³´³¹©¸¬¹©¡ ·¸³²}½¶º´¥¿¯¢­¯³²³±­¯¢µ¶³}}y´¶³³¶¡¾³²¸¥­«­¥·¤²¨©·¬± ©¸¥¨¡¯¸½¥ ((670¯¥­670F7­m¬°µ·©­»}²¥¶±¢²­·¬»¸¬»}±´³¶³¤²²¥ ´¶³¦°¬¹³¤² ²¥¸½´º¹³¤²¥´¢¸¬²´¥¶¥¯¸º´¶³·­¸ ·¸³¯³­²¢¸³´³¹©·¡¥¸³½ ²¸©¶²©¸ http://www.lucentdocs.com/ins Euroopan unionin sääntelystandardi CE-merkintä Lucent Technologies vakuuttaa täten, että PacketStar PSAX 1000 (-48 V dc ja 220 V vaihtovirtaa), PSAX 1250 (-48 V dc ja 220 V vaihtovirtaa), PSAX 2300, ja PSAX 4500 Media Gatewayt ja tässä julkaisussa dokumentoidut laitteet, täyttävät seuraavien neuvoston direktiivien keskeiset vaatimukset ja asiaankuuluvat määräykset: • Pienjännite 72/23/EY • Sähkömagneettinen yhteensopivuus (EMC) 89/336/EY • Radiolaitteet ja telepäätelaitteet 1999/5/EY PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 vi Release 10.0.0 255-700-584 Lucent PacketStar PSAX Multiservice Media Gatewayt, joita käytetään Euroopan talousalueella, on tarkoitettu liitettäväksi E1-, E3-, STM-1- ja STM-4c-verkkoihin. EU:n vaatimustenmukaisuusvakuutus voidaan nähdä tai tulostaa seuraavalta julkiselta Internet-sivulta: http://www.lucentdocs.com/ins Norme réglementaire de l’Union européenne Label CE Lucent Technologies déclare en ceci que les passerelles de média multiservices PacketStar PSAX 1000 (-48 V c.c. et 220 V ca), PSAX 1250 (-48 V c.c. et 220 V ca), PSAX 2300, et PSAX 4500 sont conformes aux exigences essentielles et autres dispositions pertinentes des directives suivantes du Conseil: • Basse tension 72/23/CEE • Compatibilité électromagnétique (CEM) 89/336/CEE • Matériel radio et terminaux de télécommunications 1999/5/CE Les passerelles de média multiservices PacketStar PSAX de Lucent, commercialisées dans l’Espace économique européen sont destinées aux connexions à des réseaux E1, E3, STM-1 et STM-4c. Les déclarations de conformité CE peuvent être consultées ou imprimées à partir du site Internet d’accès public: http://www.lucentdocs.com/ins Normativa dell’Unione Europea Apposizione del marchio CE La Lucent Technologies dichiara che i gateway multiservizio PacketStar PSAX 1000 (-48 V dc e 220 V c.a.), PSAX 1250 (-48 V dc e 220 V c.a.), PSAX 2300, e PSAX 4500 inclusi quelli documentati in seguito, rispondono ai requisiti essenziali ed ad altre norme rilevanti delle seguenti direttive del Consiglio: • Direttiva 72/23/CEE “Basse tensioni” • Direttiva 89/336/CEE sulla compatibilità elettromagnetica • Direttiva 1999/5/CE riguardante le apparecchiature radio e le apparecchiature terminali di telecomunicazione I gateway multiservizio PacketStar PSAX della lucent, impiegati nell’area economica europea (EEA), sono concepiti per il collegamento con reti E1, E3, STM-1 e STM-4c. Le dichiarazioni di conformità CE possono essere visionati o stampati presso il seguente sito Internet di pubblico accesso: http://www.lucentdocs.com/ins Norm van de Europese Unie CE-markering Lucent Technologies verklaart hierbij dat de PacketStar PSAX 1000 (-48 V dc en 220V wisselstroom), PSAX 1250 (-48 V dc en 220V wisselstroom), PSAX 2300, en PSAX 4500 Multiservice Media Gateways voldoen aan de essentiële vereisten en andere relevante bepalingen van de volgende Richtlijnen van de Raad: • Laagspanning 72/23/EEG PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Release 10.0.0 vii • Elektromagnetische compatibiliteit (EMC) 89/336/EEG • Radioapparatuur en telecommunicatie-eindapparatuur 1999/5/EG De Lucent PacketStar PSAX Multi Service Media Gateways die in de Europese Economische Ruimte (EER) zijn ingezet, zijn bestemd voor aansluiting op E1, E3, STM-1 en STM-4c netwerken. DE EU-verklaringen van overeenstemming kunnen worden bekeken of afgedrukt op de volgende Internet-site met openbare toegang: http://www.lucentdocs.com/ins Padrão Regulador da União Europeia Marca CE A Lucent Technologies vem por este meio declarar que os Concentradores de Acesso PacketStar PSAX 1000 (-48 V dc e 220V CA), PSAX 1250 (-48 V dc e 220V CA), PSAX 2300, e PSAX 4500 obedecem aos requisitos essenciais e a outras disposições relevantes das seguintes Directivas do Conselho: • Baixa Voltagem 72/23/EEC • Compatibilidade Electromagnética (EMC) 89/336/EEC • Equipamento de Rádio e Equipamento Terminal de Telecomunicações 1999/5/EC Os Concentradores de Acesso PacketStar PSAX da Lucent instalados na Área Económica Europeia (EEA) foram concebidos para serem ligados a redes do tipo E1, E3, STM-1 e STM-4c. As Declarações de Conformidade CE podem ser vistas ou impressas no seguinte sítio de acesso público da Internet: http://www.lucentdocs.com/ins Norma reguladora de la Unión Europea Marcas de la CE Por el presente, Lucent Technologies declara que las pasarelas de medios multiservicio PacketStar PSAX 1000 (-48 V cc y 220 V ca), PSAX 1250 (-48 V cc y 220 V ca), PSAX 2300, y PSAX 4500 Multiservice Media Gateways, inclusive el equipo documentado en esta publicación, están en conformidad con los requisitos esenciales y otras disposiciones pertinentes de las siguientes directrices del consejo: • Bajo voltaje 72/23/EEC • Compatibilidad electromagnética (EMC) 89/336/EEC • Equipo de radio y equipo de terminales de telecomunicaciones 1999/5/EC Las pasarelas de medios multiservicio Lucent PacketStar PSAX Multiservice Media Gateways desplegadas en el área económica europea (European Economic Area, EEA) están destinadas a conectarse en redes E1, E3, STM-1 y STM-4c. Las declaraciones de conformidad de la CE pueden verse o imprimirse en el siguiente sitio Internet de acceso público: http://www.lucentdocs.com/ins PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 viii Release 10.0.0 255-700-584 Europeiska unionens standardförordning CE-märkning Lucent Technologies deklarerar härmed att PacketStar PSAX 1000 (-48 V likström och 220 V växelström), PSAX 1250 (-48 V likström och 220 V växelström), PSAX 2300, och PSAX 4500 Multiservice Media Gateways, inklusive den i denna publikation dokumenterade utrustning, uppfyller de väsentliga kraven och andra relevanta bestämmelser som gäller enligt följande Europarådsdirektiv: • Lågspänning 72/23/EEC • Elektromagnetisk kompatibilitet (EMC) 89/336/EEC • Radioutrustning och telekommunikationskopplingsutrustning 1999/5/EC Lucent PacketStar PSAX Multiservice Media Gateways, som är placerad i EEA (European Economic Area), är avsedd för att anslutas till E1, E3, STM-1 och STM-4c nätverk. Europarådets Konformitetsdeklarationer kan ses på bildskärm eller skrivas ut på följande, för allmänheten tillgängliga Internet-ställe: http://www.lucentdocs.com/ins PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Release 10.0.0 ix PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 x Release 10.0.0 255-700-584 Table of Contents Legal Notices, Safety, and Regulatory Information . . . . . . . . . . . . . . . . . iii Copyright . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii Trademarks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii Warranty Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii Software and Hardware Limited Warranties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii Warranty Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv Safety Warnings and Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv Regulatory Standards Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv Safety and Electromagnetic Compatibility (EMC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv Telecommunications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v Regulatory Statements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v European Union Regulatory Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v CE Marking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xi List of Figures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiv xiv List of Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xv 1 Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 1-1 Purpose of This Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1 Audience for This Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1 What You Should Know . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1 Related Reading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2 Lucent Technologies Information Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2 Product Information Library . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2 Printed Documents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2 Other Publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2 About Lucent Technologies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2 For More Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2 About the PacketStar PSAX Product Family. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-3 PSAX 1000 Multiservice Media Gateway. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-3 PSAX 1250 Multiservice Media Gateway. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-3 PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Release 10.0.0 xi Table of Contents PSAX 2300 Multiservice Media Gateway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 PSAX 4500 Multiservice Media Gateway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 Text Types Used in This Document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1 . 1-5 1-5 Icons and Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 1-5 Use of Command Description Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 1-6 Use of Field Description Tables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 1-6 General Navigational Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7 1-7 Selecting Options, Fields, and Commands Using the Console Interface . . . . . . . . . . . 1-7 1-7 Help Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8 1-8 Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9 1-9 Before You Begin. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10 Comments on This Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10 2 Module Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 2-1 Overview of This Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 2-1 Connection Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2 2-2 Software Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4 2-4 Hardware Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5 2-5 Hardware Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5 2-5 Performance and Power Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6 2-6 Module Placement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6 2-6 LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7 2-7 Loopback Configuration Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7 2-7 3 3-1 Configuring Ports and Channels Using the Console . . . . . . . . . . . . . . . . . . . 3-1 Overview of This Chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 3-1 Before You Begin. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 3-1 Obtaining General Module Data and Accessing Ports and Channels. . . . . . . . . . . . . . . . . 3-1 3-1 Accessing the Equipment Configuration Window . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 3-1 Alarm Status Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6 3-6 Configuring the Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7 3-7 Configuring Ports and Channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8 3-8 Viewing Port Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-16 Configuring IMA Groups. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-19 Viewing Group Channel Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-32 Saving the Equipment Configuration and Logging Off . . . . . . . . . . . . . . . . . . . . . . . . . . 3-33 Provisioning Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-35 PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 xii Release 10.0.0 255-700-584 Table of Contents A Pin Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 Overview of This Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 Connector Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 To the PSAX 12-Port BNC Patch Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 To the PSAX 24-Port RJ Patch Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-3 To the PSAX 48-Port RJ Patch Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-5 B Reference Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1 Overview of This Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-1 Avoiding Common Errors When Configuring Interfaces. . . . . . . . . . . . . . . . . . . . . . . . . . .B-1 Optimizing SVC Call Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-2 Connection Type by Interface Type Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-2 Interface Type by I/O Module Type Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-4 Module Alarm Status Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-7 ATM Service Categories in the PSAX System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-9 ATM Service Category Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-9 Priority of ATM Service Categories in the PSAX System . . . . . . . . . . . . . . . . . . . . . . . .B-9 ATM TS, UPC, and VI Configuration Capabilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-10 ATM Traffic Shaping Capability by Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-11 ATM Traffic Shaping Sample CPS Calculation Table . . . . . . . . . . . . . . . . . . . . . . . . . .B-13 PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Release 10.0.0 xiii List of Figures 1-1 Field Description Table Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 1-2 Main Menu Help Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9 2-1 21-Port High-Density E1 IMA Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2 2-2 21-Port High-Density E1 IMA Modules Connected to 48-port RJ Patch Panel (front view of chassis, patch panel, fan tray, and heat deflector) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 2-3 21-Port High-Density E1 IMA Modules Connected to 48-port RJ Patch Panel (back view of patch panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..2-3 2-3 2-4 21-Port High-Density E1 IMA Module Connected to a 12-port BNC Patch Panel (front view of chassis and patch panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4 2-5 21-Port High-Density E1 IMA Module Connected to a 12-port BNC Patch Panel (back view of patch panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..2-4 2-4 2-6 Loopback Configuration Options on the Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8 3-1 Sample Equipment Configuration Window on a PSAX 1000 System (Page 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2 3-2 Sample Equipment Configuration Window on a PSAX 1250 System (Page 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3 3-3 Sample Equipment Configuration Window on a PSAX 2300 or PSAX 4500 System (Page 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3 3-4 Sample Equipment Configuration Window on a PSAX 1000, PSAX 2300, or PSAX 4500 System (Page 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4 3-5 Sample Equipment Configuration Window on a PSAX 1250 System (Page 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4 3-6 Console Interface Main Menu Window (Equipment Configuration Selected) . . . . . . . . . . . . 3-8 3-7 Equipment Configuration Window (As Displayed on the PSAX 1250, PSAX 2300, and PSAX 4500 Console) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9 3-8 Equipment Configuration Window (As Displayed on the PSAX 1000 Console) . . . . . . . . . . 3-9 3-9 21-Port High Density E1 IMA Module Configuration Window . . . . . . . . . . . . . . . . . . . . . . 3-10 3-10 21-Port High Density E1 IMA Module Port and Channel Configuration Window . . . . . . . 3-11 3-11 3-11 21-Port High Density E1 IMA Port Statistics Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-17 3-12 High-Density E1 IMA Group Configuration Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-19 3-13 IMA Virtual Group Channel Configuration Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-20 3-14 IMA Group Configuration Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-22 3-15 IMA Group Channel Statistics Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-32 3-16 Save Configuration [Modified] (Before Saving) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-34 B-1 Combining the UPC Feature and Either the TS or VI Feature on a Connection . . . . . . . . . . B-11 PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Release 10.0.0 xiv List of Tables 1-1 Text Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 1-2 Command Description Table Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 1-3 System Responses to Selecting Options, Fields, or Commands. . . . . . . . . . . . . . . . . . . . . . . . 1-7 1-4 Shortcut Keys for Navigating Console Interface Windows . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8 2-1 Physical Hardware Specifications for the PSAX I/O Module . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5 2-2 Performance and Power Specifications for the PSAX Module . . . . . . . . . . . . . . . . . . . . . . . . 2-6 2-3 LED Indicators for the 21-Port High-Density E1 IMA Module . . . . . . . . . . . . . . . . . . . . . . . . . 2-7 3-1 Equipment Configuration Window Field Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5 3-2 Module Alarm Status Descriptions on the Equipment Configuration Window . . . . . . . . . . . . 3-7 3-3 21-Port High Density E1 IMA Module Port and Channel Configuration Window Field Descriptions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-12 3-12 3-4 21-Port High-Density E1 IMA Module—Line Status Alarm Descriptions . . . . . . . . . . . . . . . . 3-15 3-15 3-5 21-Port High Density E1 IMA Port Statistics Window Field Descriptions . . . . . . . . . . . . . . . . 3-18 3-18 3-6 IMA Virtual Group Channel Configuration Window Field Descriptions . . . . . . . . . . . . . . . . 3-21 3-21 3-7 IMA Group Configuration Window Field Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-23 3-23 3-8 IMA Group Channel Statistics Window Field Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . 3-33 3-33 3-9 Messages Generated after the Save Configuration Process . . . . . . . . . . . . . . . . . . . . . . . . . 3-35 3-35 A-1 21-Port High-Density E1 IMA Module Connector, Cable, and PSAX 12-Port BNC Patch Panel Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2 B-1 Connection Type by Interface Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-3 B-2 Interface Type by I/O Module Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-4 B-3 Module Alarm Status Descriptions on the Equipment Configuration Window . . . . . . . . . . . . B-7 B-4 PSAX System-Supported Quality of Service Categories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-9 B-5 Mapping ATM Service Categories to PSAX System Priority Levels. . . . . . . . . . . . . . . . . . . . . B-10 B-10 B-6 ATM Traffic Shaping, UPC Support, and VI Support Configuration Compatibility. . . . . . . . . B-10 B-7 ATM Traffic Management Capabilities by Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-11 B-11 B-8 ATM Traffic Shaping CPS Calculation Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-13 B-13 PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Release 10.0.0 xv PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 xvi Release 10.0.0 255-700-584 1 Getting Started Purpose of This Guide The PacketStar®21-Port High-Density E1 IMA Module User Guide provides a description of the 21-Port High-Density E1 IMA module. It also provides information on how to configure the module ports and channels. For information on configuring interfaces and provisioning connections through the PSAX console interface, see the PacketStar® PSAX Connections Provisioning Guide. If the Navis® EMS-PSAX interface is being used, see the Navis® EMS-PSAX Interface and Connection Provisioning Guide. Note: If you are using this module for the first time, you should read through this guide in its entirety before beginning the configuration process. The chapters in this guide are arranged in the logical order of normal configuration and should be performed in that order for the module to operate successfully. Audience for This Guide The information in this guide is intended for users who will configure ports and channels for the 21-Port High-Density E1 IMA module in the PSAX Multiservice Media Gateway system. What You Should Know Before you use this document or operate a PSAX system, you should already understand and have experience with the following: • ATM Forum, Frame Relay Forum, and other telecommunications specifications • Ethernet network capabilities • Internet Protocol capabilities • Data network design • Telephony network design PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Release 10.0.0 1-1 Chapter 1 Getting Started Related Reading Related Reading Lucent Technologies Information Products Product Information Library To install, operate, and configure your PSAX system and I/O and server modules, read the PSAX publications provided on your Lucent Technologies PacketStar® PSAX Multiservice Media Gateways Product Information Library CD-ROM. Printed Documents For your convenience, many of the documents included on the PacketStar® PSAX Multiservice Media Gateways Product Information Library CD-ROM are also available in printed form. You can order these documents through the Lucent Technologies Customer Information Center Web site at: http://www.lucentdocs.com. Other Publications Numerous books are currently available on the subject of basic telecommunications technology and specific protocols. In addition to such general reading, you should also be familiar with the industry specifications identified in this guide. About Lucent Technologies Lucent Technologies is the communications systems and technology company formed through the restructuring of AT&T. We bring with us a tradition of more than 125 years of experience and a dedication to superior customer service. Lucent Technologies manufactures, sells, and services a complete line of customer premises communications units, and commercial and multimedia communications and messaging systems designed and supported by our research and development unit, Bell Laboratories. Our legacy and our spirit of innovation allow Lucent to provide our customers with the tools needed to communicate effectively, any time and anywhere, and to integrate the latest technologies into real-life solutions that help make business work. For More Information To learn more about the PacketStar PSAX family of Multiservice Media Gateways and the complete line of Lucent Technologies products, visit our Web site at http://www.lucent.com. PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 1-2 Release 10.0.0 255-700-584 Chapter 1 Getting Started About the PacketStar PSAX Product Family About the PacketStar PSAX Product Family Lucent Technologies provides a complete range of PSAX Multiservice Media Gateways in the PacketStar PSAX family. PSAX 1000 Multiservice Media Gateway The PacketStar PSAX 1000 Multiservice Media Gateway is designed to provide a full range of central office-based multiservice media gateway functions in a small, competitively-priced package suitable for customer premise deployment. Ideal for central office, large enterprise, or wireless cell site multiservice media gateway applications, the PSAX 1000 system provides highly reliable network access for time-division multiplex voice, frame relay, 10/100BASE-T Ethernet, and ATM data applications. When it is functioning in a redundant operating mode and after it has experienced a single-point failure, the PSAX 1000 system provides up to 630 Mbps of ATM cell bus capacity. The total ATM cell bus capacity of the system may also be scaled to provide nonblocking, nonredundant chassis bandwidths beyond 630 Mbps. Supporting up to five slots (19–inch chassis) for I/O and server modules—with a full range of interfaces such as DS0A, DS1/E1, DS3/E3, OC-3, OC-3c/STM-1, OC-12c/STM-4c, 10/100BASE-T Ethernet, and serial—the PSAX 1000 system is a cost-effective access switch solution for connecting to legacy equipment. PSAX 1250 Multiservice Media Gateway The PacketStar PSAX 1250 Multiservice Media Gateway is designed to provide a full range of central office-based multiservice ATM access functions. Ideal for the central office or a large enterprise’s multiservice media gateway, the PSAX 1250 system provides highly reliable network access for time-division multiplex voice, frame relay, 10/100BASE-T Ethernet, and ATM data applications. When it is functioning in a redundant operating mode and after it has experienced a single-point failure, the PSAX 1250 system provides up to 600 Mbps of ATM cell bus capacity. The total ATM cell bus capacity of the system may also be scaled to provide nonblocking, nonredundant chassis bandwidths beyond 600 Mbps. Supporting 10 slots (19-inch chassis) or 14 slots (23-inch chassis) for I/O and server modules—with a full range of interfaces such as DS0A, DS1/E1, DS3/E3, OC-3, OC-3c/STM-1, OC-12c/STM-4c, 10/100BASE-T Ethernet, and serial—the PSAX 1250 system is a cost-effective access switch solution for interworking with legacy equipment. PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Release 10.0.0 1-3 Chapter 1 Getting Started About the PacketStar PSAX Product Family PSAX 2300 Multiservice Media Gateway The PacketStar PSAX 2300 Multiservice Media Gateway offers carrier-grade, high-density multiservice ATM access functions. Designed as the multiservice media gateway for the central office or for a large enterprise customer, the PSAX 2300 system provides network access for time-division multiplex voice, frame relay, 10/100BASE-T Ethernet, and ATM data applications. When it is functioning in a redundant operating mode and after it has experienced a single-point failure, the PSAX 2300 system provides up to 1.9 Gbps of ATM cell bus capacity. The total ATM cell bus capacity of the system may also be scaled to provide nonblocking, nonredundant chassis bandwidths beyond 1.9 Gbps. Supporting 15 slots for I/O and server modules—with provisions for OC-3, OC-3c/STM-1, and OC-12c/STM-4c interfaces with 1:1 protection, 1:1 DS1 module protection switching, and a full range of interfaces such as DS0A, DS1/E1, DS3/E3, 10/100BASE-T Ethernet, and serial—the PSAX 2300 system solves demanding and diverse network design challenges with ease. PSAX 4500 Multiservice Media Gateway The PacketStar PSAX 4500 Multiservice Media Gateway provides carrier-class reliability, with an unmatched range of service capabilities, end-to-end traffic prioritization, “any-service, any-channel” flexibility, and breakthrough voice technology. Ideal for the central office or a large enterprise multiservice media gateway, the PSAX 4500 system provides highly reliable network access for time-division multiplex voice, frame relay, 10/100BASE-T Ethernet, and ATM data applications. When it is functioning in a redundant operating mode and after it has experienced a single-point failure, the PSAX 4500 system provides up to 4.2 Gbps of ATM cell bus capacity. The total ATM cell bus capacity of the system may also be scaled to provide nonblocking, nonredundant chassis bandwidths beyond 4.2 Gbps. The high-performance midplane design supports 15 interface slots. Module protection for two groups of four or six multiport DS3, STS-1e, or E3 modules is provided via an N:1 protection scheme using rear access line interface modules. The protection module provides backup so that on the failure of any one of the modules in a group, traffic is maintained. A single PSAX 4500 system at the edge of the carrier network can transition traffic from a large number of network customers over high-speed DS1/E1 IMA, DS3/E3, OC-3, OC-3c/STM-4c, and OC-12c/STM-4c trunks into the ATM core, managing the whole quickly and efficiently, down to the individual permanent virtual circuit. Through the use of the latest DSP voice technology, the PSAX 4500 system supports advanced voice traffic over ATM (VToA) services for up to 6048 DS0 channels. As a multiservice media gateway—with H.248 call control, CAS, PRI, GR-303, and V5.2 protocols, 3-Port DS3/STS-1e, 1-Port OC-3/STM-1 CES, and Tones and Announcements modules—the PSAX 4500 system provides packet solutions for voice over xDSL, trunking, tandem, and PRI offload switching. PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 1-4 Release 10.0.0 255-700-584 Chapter 1 Getting Started Conventions Conventions Text Types Used in This Document This guide uses a different typeface to denote text displayed on console interface windows and equipment, as well as data you enter. Table 1-1 shows how each typographical convention is used. Table 1-1. Text Conventions Appearance How it is used SANS SERIF BOLD, ALL CAPS Labels on module panels, chassis faceplates, or other hardware Fixed-width normal Message text displayed on the user interface window Serif bold • Button name (GUI interface) or command name (console interface) on the user interface window • Literal text for values that the user types or selects from predefined sets of values for fields • Commands or literal argument values Fixed-width bold System prompts displayed on the user interface window Serif italics • A variable name or string for which you will substitute your own information • An argument or parameter on a command line for which you will substitute your own information Icons and Symbols Refer to the procedures within this guide for important safety information and proper procedures. Standard icons and symbols to alert you to dangers, warnings, cautions, and notes are described as follows: ! DANGER: Warnings for a personal injury hazard are identified by this format. ! WARNING: Warnings relating to risk of equipment damage or failure are identified by this format. ! CAUTION: Warnings relating to risk of data loss or other general precautionary notes are identified by this format. Note: Identifies additional information pertinent to the text preceding this note. PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Release 10.0.0 1-5 Chapter 1 Getting Started Conventions Use of Command Description Tables All illustrations for configuration windows in this guide for the PSAX system console interface are followed by a command description table describing the command functions displayed on the window (near the bottom of the window). You should read all the information in the command description table, especially when first using a window, because these descriptions may have special instructions or configuration constraints provided in the Function column by use of the Note: text convention (see Table 1-2). Table 1-2. Command Description Table Example Command Function Bring All Interfaces Brings the out-of-service configured interfaces to in-service status. Into Service Note: In GR-303 configuration, it is critical to bring into service only those channels actively configured with DS1 ports. Use of Field Description Tables For all illustrations for configuration windows in this guide for both the PSAX system console interface and the EMS-PSAX, the field description tables normally follow the command description tables. Field description tables define the editable and the display-only fields, their functions, valid values, and constraints, if applicable. As in the command description tables, the Note: text convention is also used, where appropriate, in the field description tables to alert the user to special instructions or configuration constraints (see Figure 1-1). Identifies editable fields or display-only fields on screens Identifies initial field value default Field Name Field Values Interface Type Identifies available range for field value when applicable Default: 0 Range: 0-22 Format: Numeric Describes the function of the field and special instructions for configuring modules Description Specifies the type of end-to-end connection protocol that governs the transmission parameters for this configured port and channel interface. Note: When certain types of interfaces are selected in this field, other configuration fields are displayed on this window. Identifies field value format as Numeric, Predefined Alphanumeric, Hexadecimal, or Valid Dotted Quad. Decribes special instructions or configuration constraints Figure 1-1. Field Description Table Example PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 1-6 Release 10.0.0 255-700-584 Chapter 1 Getting Started General Navigational Guidelines General Navigational Guidelines Selecting Options, Fields, and Commands Using the Console Interface Follow these guidelines to select an option, field, or command on the PSAX console interface windows and to navigate through the windows: • To select an option, field, or command, do one of the following: ~ Press the Up, Down, Left, or Right Arrow to highlight (reverse video image) the option name, field name, or command you want to select and press Enter as many times as necessary until the field choice you want is displayed. ~ Use the alternate keys, K=UP, H=LEFT, L=RIGHT to highlight (reverse video image) the option name, field name, or command you want to select and press Enter. (You can optionally redefine these alternate keys from the User Options window, which is accessible from the Console Interface Main Menu window.) ~ To quickly select a command, you can also simultaneously press Ctrl and the letter underlined in the command. Once an option name, field, or command is selected, the system responds as described in Table 1-3. Table 1-3. System Responses to Selecting Options, Fields, or Commands For a selected... the following occurs: option name The window corresponding to the option name is displayed. field The following variations occur: • The field entry area is blank or contains the default or previously entered value. Press Enter to enter or change data in this field. Press Enter again to exit edit mode. • The field entry area, like the field name, is displayed in reverse video image and contains a predefined set of values, which you can view or select by pressing Enter to navigate forward through these values. To navigate backward through these field values, press Ctrl+H or the Backspace key. Read-only fields, which you cannot change, are enclosed in square brackets (example: [LineStatus]). command The following variations occur: • A message in the information line indicating an error or successful completion of the command is displayed. • The next higher level or previous window (window name) is displayed. • The next lower level or succeeding window (window name) is displayed. • To navigate through the Console windows, use the shortcuts listed in Table 1-4. PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Release 10.0.0 1-7 Chapter 1 Getting Started Help Information Table 1-4. Shortcut Keys for Navigating Console Interface Windows If you want to... press... redisplay the previous window Ctrl+B on the window. redisplay the Console Interface Main Menu window Ctrl+G on the window. refresh the window Ctrl+R on the window. On all the PSAX system windows, each command or menu option has an underlined letter. The control key plus an underlined letter is a shortcut to that command or menu option. You can use the navigation keys and hotkeys with the Caps Lock key on or off. Always observe the status line at the bottom of the window for instructions and information. Help Information The Help windows are accessible from any window in the PSAX system console interface. To access the Help windows, press the ? (Question Mark) key on any window. In addition to the Help windows, the Console Interface windows display contextual help in the information line at the bottom of each window. Contextual help provides information about the command or field currently highlighted on that window. The information line also displays error codes and responses to commands. All responses and notifications are recorded in a trap log. See the PacketStar® PSAX Simple Network Management Protocol (SNMP) Trap Reference Guide for details on displaying the trap log and obtaining explanations of the trap messages. To view the Help windows from the Console Interface Main Menu window, perform the following procedure. Begin 1 On the window for which help is desired, press the ? (question mark) key. The Help window for the current console window is displayed (see Figure 1-2). PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 1-8 Release 10.0.0 255-700-584 Chapter 1 Getting Started Technical Support Your site name appears here after initial configuration Information Line Figure 1-2. Main Menu Help Window 2 To display the remaining Help windows for the current console window, press the Down Arrow key. 3 To scroll backward through the Help windows for the current console window, press the Up Arrow key. 4 To exit Help and return to the current console window, press the Enter key. End Technical Support If you experience a problem with the 21-Port High-Density E1 IMA module, refer to the Lucent Technologies Product Warranty Registration Information, which accompanied your shipment, for instructions on obtaining support in your area. PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Release 10.0.0 1-9 Chapter 1 Getting Started Before You Begin Before You Begin Before you start configuring and using your new 21-Port High-Density E1 IMA module, be sure you: • Record your site-specific specifications such as the IP addresses you will use, and the connections and interfaces you will need. Decide which user names and passwords you will assign. • Make sure you have IP connectivity to all PSAX devices to be managed • Determine the numbering scheme for any in-band management connections you will be using Comments on This Guide To comment on the PacketStar®21-Port High-Density E1 IMA Module User Guide, please complete the comment card at the following web address: http://www.lucent-info.com/comments/ You can also email your comments to [email protected]. Include the following information: Title: PacketStar®21-Port High-Density E1 IMA Module User Guide Release number: Release 10.0.0 Document number: 255-700-584 Issue number: Issue 1 Publication date: December 2004 PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 1-10 Release 10.0.0 255-700-584 2 Module Description Overview of This Module The 21-Port High-Density E1 IMA module (see Figure 2-1) provides a line rate of 2.048 Mbps per port. The module’s inverse multiplexing for ATM capabilities permit a user to strap 2 to 21 of the physical ports together to create ATM interfaces that support up to 43 Mbps of bandwidth. A maximum of 10 IMA groups may be configured per module. This module offers native E1 ATM services and E1 IMA services, including permanent virtual circuits, soft permanent virtual circuits, and switched virtual circuits. The module supports the Traffic Shaping feature on ATM UNI v3.n, UNI v4.0, IISP, PNNI, and ILMI interfaces. This functionality enables service providers to offer both individual unchannelized E1 ATM services (without IMA overhead) and multiple E1 IMA group services using a single module. Using the IMA protocol, this module provides an effective method of combining the transport bandwidths of multiple E1 links that are grouped to collectively provide higher intermediate rates. This technique involves inverse multiplexing and de-multiplexing of ATM cells in a cyclical fashion among links grouped to form a higher bandwidth logical link whose rate is approximately the sum of the link rates. This is referred to as an IMA group. From the system’s viewpoint, these IMA groups are simply new ATM interfaces sized as multiples of E1. (Refer to Inverse Multiplexing for ATM Version 1.1, afphy-0086.001.) PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Release 10.0.0 2-1 Chapter 2 Module Description Connection Options FAIL ACTIVE PORTS 1-12 PORTS 13-21 HD E1 IMA Figure 2-1. 21-Port High-Density E1 IMA Module Connection Options The 21-Port High-Density E1 IMA module connects to user equipment via a standard 10-foot Lucent cable (COMCODE 300550639) with an RJ-48H connector. Typically, this cable is used to connect the module to one of the following patch panels within the same or an adjacent Telco frame: • PSAX 12-Port BNC Patch Panel (impedance 75 ohms) • PSAX 24-Port RJ Patch Panel (impedance 120 ohms) • PSAX 48-Port RJ Patch Panel (impedance 120 ohms) The PSAX 24-Port RJ Patch Panel uses ports 1–21 (ports 22-24 are not used). The PSAX 48-Port RJ Patch Panel uses ports 1–21 and 25–45 (ports 22–24 and 46–48 are not used). The Lucent cable can be extended for short-haul links of up to 500 feet (with 5 dB cable loss) by connecting the Lucent cable to an Avaya cable (p/n 1010025AGY CUSTL, at -1 dB per 100 feet), or equivalent. Use RJ-48H connectors (for example, Cinch p/n 57-10500-271A and Cinch p/n 57-20500-7A) on the extension cable to link the Lucent cable to the PSAX Patch Panels. PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 2-2 Release 10.0.0 255-700-584 Chapter 2 Module Description Connection Options Figure 2-2 and Figure 2-3 show both connectors of two modules connected to a PSAX 48-Port RJ Patch Panel (COMCODE 300298544). Figure 2-4 and Figure 2-5 show one connector of a module connected to a PSAX 12-Port BNC Patch Panel (COMCODE 300298569). Each port consists of a pair of transmit and receive signals. These components are separately orderable. Heat Deflector PORT 13-24 PORT 1-12 Patch Panel PacketStar36$;33 1.75" SPACER FAIL FAIL FAIL FAIL FAIL FAIL FAIL FAIL FAIL FAIL FAIL FAIL ACTIVE ACTIVE ACTIVE ACTIVE ACTIVE ACTIVE ACTIVE ACTIVE ACTIVE ACTIVE ACTIVE ACTIVE ACTIVE ACTIVE HD E1 IMA HD E1 IMA SERIAL DS1 IMA DS1 IMA DS1 IMA DS1 IMA DS3 ATM DS3 ATM DS3 ATM CPU2 CPU2 STRATUM 3 4 STRATUM 3 4 Power Supply (110V AC) Model 20N04 CLK LOS CLK LOS non-redundant FAIL FAIL FAIL FAIL ACTIVE ACTIVE Power Supply (110V AC) Model 20N04 WARNINGS: 2 ETHERNET PORTS 1-12 LOS LOS LOS LOS 1 1 1 1 LOS LOS TX TX 2 2 RX 3 3 3 3 4 4 4 4 5 5 5 5 6 6 6 6 RX PORTS 13-21 PORTS 13-21 B ATTACH POWER CORD ONLY DANGER: HIGH VOLTAGE WHEN UNIT IS FULLY SEATED IN CHASSIS CONSOLE TX LOS RX CAUTION: DISCONNECT POWER BEFORE CHANGING FUSE. REPLACE ONLY WITH FUSE OF SAME TYPE AND RATING. Power Supply A PSAX1250 FAN TRAY RX LOAD 6 LOAD LOS TX TX RX RX WARNINGS: SEE INSTALLATION INSTRUCTIONS BEFORE CONNECTING THIS MODULE non-redundant ENSURE FACILITY POWER IS COMPATIBLE WITH VOLTAGE RATING OF THIS MODULE 2 4 LOS 5 ETHERNET LOS TX CONSOLE 2 3 PORTS 1-12 PORTS 1-12 A 1 SEE INSTALLATION INSTRUCTIONS BEFORE CONNECTING THIS MODULE ENSURE FACILITY POWER IS COMPATIBLE WITH VOLTAGE RATING OF THIS MODULE ATTACH POWER CORD ONLY DANGER: HIGH VOLTAGE WHEN UNIT IS PSAX 1250 FULLY SEATED IN CHASSIS UNPLUG POWER CORD BEFORE REMOVING THIS MODULE UNPLUG POWER CORD BEFORE REMOVING THIS MODULE MULTIPLE POWER CONNECTIONS, DISCONNECT TWO POWER CORDS BEFORE SERVICING CHASSIS MULTIPLE POWER CONNECTIONS, DISCONNECT TWO POWER CORDS BEFORE SERVICING CHASSIS CAUTION: DISCONNECT POWER BEFORE ACTIVE Fuse A CHANGING FUSE. REPLACE ONLY WITH FUSE OF SAME TYPE AND RATING. Power Supply B ALARMS Fuse B FAN FAIL Fan Tray Non-redundant -48 V 0.5 A -48 V 0.5 A 1.0A 1.0A Figure 2-2. 21-Port High-Density E1 IMA Modules Connected to 48-port RJ Patch Panel (front view of chassis, patch panel, fan tray, and heat deflector) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 Figure 2-3. 21-Port High-Density E1 IMA Modules Connected to 48-port RJ Patch Panel (back view of patch panel) PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Release 10.0.0 2-3 Chapter 2 Module Description Software Features PacketStar36$;33 FAIL FAIL FAIL FAIL FAIL FAIL FAIL FAIL FAIL FAIL FAIL FAIL ACTIVE ACTIVE ACTIVE ACTIVE ACTIVE ACTIVE ACTIVE ACTIVE ACTIVE ACTIVE ACTIVE ACTIVE ACTIVE ACTIVE HD E1 IMA HD E1 IMA SERIAL DS1 IMA DS1 IMA DS1 IMA DS1 IMA DS3 ATM DS3 ATM DS3 ATM CPU2 CPU2 STRATUM 3 4 STRATUM 3 4 Power Supply ( AC ) CLK LOS CLK LOS non-redundant FAIL FAIL FAIL FAIL ACTIVE ACTIVE Power Supply ( AC ) WARNINGS: 2 PORTS 1-12 1 PORTS 1-12 A 3 LOS LOS LOS LOS 1 1 1 1 2 2 2 2 3 3 3 3 4 4 4 4 5 5 5 5 6 6 6 LOS LOS TX RX 4 CONSOLE LOAD LOAD ATTACH POWER CORD ONLY DANGER: HIGH VOLTAGE WHEN UNIT IS FULLY SEATED IN CHASSIS LOS TX TX TX RX RX RX non-redundant ENSURE FACILITY POWER IS COMPATIBLE WITH VOLTAGE RATING OF THIS MODULE RX LOS WARNINGS: SEE INSTALLATION INSTRUCTIONS BEFORE CONNECTING THIS MODULE SEE INSTALLATION INSTRUCTIONS BEFORE CONNECTING THIS MODULE ENSURE FACILITY POWER IS COMPATIBLE WITH VOLTAGE RATING OF THIS MODULE ATTACH POWER CORD ONLY DANGER: HIGH VOLTAGE WHEN UNIT IS FULLY SEATED IN CHASSIS UNPLUG POWER CORD BEFORE REMOVING THIS MODULE UNPLUG POWER CORD BEFORE REMOVING THIS MODULE MULTIPLE POWER CONNECTIONS, DISCONNECT TWO POWER CORDS BEFORE SERVICING CHASSIS MULTIPLE POWER CONNECTIONS, DISCONNECT TWO POWER CORDS BEFORE SERVICING CHASSIS 6 -21 PORTS 1-12 6 PORTS 13-21 PORTS 13-21 5 ETHERNET CONSOLE TX RX LOS ETHERNET LOS TX Figure 2-4. 21-Port High-Density E1 IMA Module Connected to a 12-port BNC Patch Panel (front view of chassis and patch panel) 1 1 RX 2 2 TX RX 3 3 TX RX 4 4 TX RX 5 5 TX RX 6 6 TX RX 7 7 TX RX 8 8 TX RX 9 9 TX RX 10 10 TX RX 11 11 TX RX 12 12 TX RX TX Figure 2-5. 21-Port High-Density E1 IMA Module Connected to a 12-port BNC Patch Panel (back view of patch panel) You may also connect the 21-Port High-Density E1 IMA module to a 24-port RJ Patch Panel (COMCODE 300298551). See the Packetstar® PSAX CO Patch Panel and Cable Installation Guide (255-700-117, Issue 2) for instructions. Further connections to user equipment may be made per the specifications outlined in ANSI T1.403-1999. See Appendix A, ”Pin Configurations,” for more details. Software Features The 21-Port High-Density E1 IMA module supports the following protocols and services: • Protocols: ATM, IMA • ATM services over IMA groups: ~ ATM UNI 3.0, 3.1, 4.0, and ILMI with traffic shaping ~ IISP user and IISP network with traffic shaping PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 2-4 Release 10.0.0 255-700-584 Chapter 2 Module Description Hardware Features ~ ATM PNNI with traffic shaping Hardware Features The 21-Port High-Density E1 IMA module provides the following hardware features: • Number of ports: 21 • Connector type: 2 Mini-Champ connectors • Line rate: 2.048 Mbps • Physical interfaces supported: ITU-T G.703, ITU-T G.704 • Line encoding mode: HDB3 (default), AMI • Loopback capabilities: line loopback, local loopback • Line buildout: N/A • Framing mode: CRC4-CAS Hardware Specifications Table 2-1 provides the general physical hardware and environmental specifications for the PSAX I/O module. Table 2-1. Physical Hardware Specifications for the PSAX I/O Module Specification Description Dimensions 17.3 cm H x 2.41 cm W x 24.1 cm D (6.8 in. H x 0.95 in. W x 9.5 in. D) Weight 0.59 kg (1.3 lb.) Operating temperature range for all the 0° to 50° C (32° to 122° F) PSAX 1250, PSAX 2300, and PSAX 4500 systems Operating temperature range for the PSAX 1000 systems For AC-powered PSAX 1000 systems: 0° to 50° C (32° to 122° F) For DC-powered PSAX 1000 systems: -20° to 60° C (-4° to 140° F) with a cold start minimum of 0° C (32° F) Operating humidity range for all chassis 5% to 85% relative humidity Operating altitude range for all chassis 60 meters (197 feet) below sea level to 4,000 meters (13,123 feet) above sea level Storage temperature range for all chassis -40° to 70° C (-40° to 158° F) Storage humidity range for all chassis 0% to 90% noncondensing PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Release 10.0.0 2-5 Chapter 2 Module Description Hardware Features Performance and Power Specifications Table 2-2 provides the chassis speed, power consumption, and memory allocation specifications for this PSAX module. Table 2-2. Performance and Power Specifications for the PSAX Module Module 23N34 21-Port High-Density E1 IMA 1 2 3 Total Amount of SDRAM 24 MB Module Maximum Program and Input Data Space Buffer1 7 MB 4 MB Output Buffer2 Chassis Speed3 13 MB (212,992) Low Speed Maximum Power Consumption 14.5 W The I/O buffers carry 16,384 cells per megabyte. Indicates the size of the output buffer followed by the maximum number of 64-byte cells in the output buffer. This column relates only to the speed at which the module communicates within the chassis. A high-speed module will communicate at high speed (1.2 Gbps) in a chassis that has a high-speed bus (PSAX 4500 chassis). High-speed modules will communicate at 600 Mbps in any other chassis. Low-speed modules will always communicate at 600 Mbps in any chassis. Module Placement The 21-Port High-Density E1 IMA module is installed in any PSAX chassis slot intended to contain an I/O or server module. If you are installing the module in a newly installed PSAX chassis, be sure to follow your facility site plan for placing this module in the correct location in the chassis. PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 2-6 Release 10.0.0 255-700-584 Chapter 2 Module Description Loopback Configuration Options LED Indicators Table 2-3 describes how the light-emitting diode (LED) indicators on the 21-Port High-Density E1 IMA module faceplate respond to different module conditions. These LEDs indicate if the module has been installed properly. Table 2-3. LED Indicators for the 21-Port High-Density E1 IMA Module Module Status Initial Power-On No Configured Ports LED One or No Cable on More Port Configured Ports Cable on Port FAIL (red) Lights briefly1 Not lit Lights only Not when the Applicable module is not functioning Not Applicable ACTIVE (green) Lights briefly1 Not lit Lights only Not when the Applicable module is functioning properly Not Applicable 1 Note: After power is initially applied to the system and the system boot is complete, the FAIL and ACTIVE LEDs indicate whether the module has no configured ports (red), or one or more configured ports (green). Loopback Configuration Options To aid network troubleshooting and testing, loopback capability is provided for the 21-Port High-Density E1 IMA module. The loopback option on the module port and channel configuration window for the module enables you to verify the integrity of a port by transmitting a received signal back to the source. Selecting a loopback option is described in the module configuration procedure. Figure 2-6 illustrates the line loop, payload loop, and local loop options. PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Release 10.0.0 2-7 Chapter 2 Module Description Loopback Configuration Options Line Loop Payload Loop Line Driver Signal Receiver Port Connector Port Connector Framing Chip Backplane Connector Backplane Connector Local Loop Line Driver Receiver Backplane Connector Figure 2-6. Loopback Configuration Options on the Module PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 2-8 Release 10.0.0 255-700-584 3 Configuring Ports and Channels Using the Console Overview of This Chapter This chapter describes how to use the console interface to perform the following tasks on the 21-Port High-Density E1 IMA module: • “Obtaining General Module Data and Accessing Ports and Channels” • “Configuring Ports and Channels” • “Configuring IMA Groups” • “Saving the Equipment Configuration and Logging Off” Before You Begin Be sure to complete the following tasks first before configuring the 21-Port High-Density E1 IMA module: • Configure your basic system (see “Configuring the System for Your Site” in the PacketStar® PSAX Multiservice Media Gateway User Guide). • Configure the Stratum 3–4 module (see “Configuring the Stratum 3–4 Module” in the PacketStar® PSAX Multiservice Media Gateway User Guide). When configuring the 21-Port High-Density E1 IMA module using the console interface, display-only fields are displayed in square brackets ([ ]). Obtaining General Module Data and Accessing Ports and Channels This section describes how to obtain product, model, version, and serial number data about a module from the Equipment Configuration window. In addition, the window provides operational status and alarm conditions on each installed module. You also use this window to access the port and channel configuration windows for the PSAX modules. Accessing the Equipment Configuration Window Perform the following procedure to access the Equipment Configuration window. PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Release 10.0.0 3-1 Chapter 3 Configuring Ports and Channels Using the Console Obtaining General Module Data and Accessing Ports and Channels Begin 1 On the Console Interface Main Menu window, select the Equipment Configuration option. The Equipment Configuration window is displayed (see Figure 3-1 through Figure 3-5). 2 View the operational and alarm status, software version, PEC, and serial number data of the installed modules. 3 When you are ready to begin configuring the ports and channels of the module, select the line displaying the name of the module you want to configure. 4 Proceed to the section, “Configuring the Ports,” for module configuration procedures. Note: The sample Equipment Configuration windows in the following figures may not show the actual module you are configuring. These figures illustrate the variations of slot configurations for the different PSAX chassis displayed on the Equipment Configuration window. End Figure 3-1. Sample Equipment Configuration Window on a PSAX 1000 System (Page 1) PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 3-2 Release 10.0.0 255-700-584 Chapter 3 Configuring Ports and Channels Using the Console Obtaining General Module Data and Accessing Ports and Channels Figure 3-2. Sample Equipment Configuration Window on a PSAX 1250 System (Page 1) Figure 3-3. Sample Equipment Configuration Window on a PSAX 2300 or PSAX 4500 System (Page 1) PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Release 10.0.0 3-3 Chapter 3 Configuring Ports and Channels Using the Console Obtaining General Module Data and Accessing Ports and Channels Commands Figure 3-4. Sample Equipment Configuration Window on a PSAX 1000, PSAX 2300, or PSAX 4500 System (Page 2) Figure 3-5. Sample Equipment Configuration Window on a PSAX 1250 System (Page 2) The commands in this window have the following functions. PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 3-4 Release 10.0.0 255-700-584 Chapter 3 Configuring Ports and Channels Using the Console Obtaining General Module Data and Accessing Ports and Channels Command Function Update Display Refreshes the current status of the modules in the PSAX chassis. Page Down Displays the second page of the Equipment Configuration window. This command toggles with Page Up. Page Up Displays the first page of the Equipment Configuration window. This command toggles with Page Down. Interface by Name Displays the Interface Name Table window on which you can view all the interface names in the PSAX system. Go Back to Main Menu Redisplays the Console Interface Main Menu window. Field Description The display-only fields on this window are described in Table 3-1. Table 3-1. Equipment Configuration Window Field Descriptions Field Name Field Value Description Slot Default: N/A Displays the slot number in the PSAX chassis. Range: 1–25, depends on chassis type Format: Numeric Module Type Default: N/A Range: N/A Format: Predefined Displays the type of the module in the slot. When a module is inserted into the chassis, its name is displayed in the Module Type field next to the slot number. When the module is removed from the chassis, its name is no longer displayed in the Module Type field and is replaced with None. Status Default: Unknown Range: N/A Format: Predefined Displays the operational status of the module. Unknown Indicates that the module has not been configured. Primary Indicates one of the following: • at least one port or channel on an I/O module has been configured. • a CPU module is functioning as the primary CPU module. Standby Indicates one of the following: • a module in redundant systems is operating as the standby (backup) module to the primary (active) module. • a CPU module in redundant systems is functioning as the standby (backup) CPU module. Default: No Alarm Range: N/A Format: Predefined Displays the present alarm condition of the module. For the alarm status conditions, see the table “Alarm Status Descriptions for Modules” following this table. Alarm Status PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Release 10.0.0 3-5 Chapter 3 Configuring Ports and Channels Using the Console Obtaining General Module Data and Accessing Ports and Channels Table 3-1. Equipment Configuration Window Field Descriptions (Continued) Field Name Field Value Description SW # Default: N/A Range: N/A Format: Predefined Displays the version of PSAX system software with which the modules’ firmware was released. The software version is encoded in the module firmware. Because not all modules require firmware upgrades with every new PSAX system software release, the software version that is displayed in this window may be lower than the CPU system software that is currently running on the PSAX system. See the most recent Release Note document for the latest software and firmware lineup information. PEC Default: N/A Range: N/A Format: Predefined Displays the product element code (PEC) used to identify and order this type of module. The PEC is encoded in the module bootloader. Serial # Default: N/A Range: N/A Format: Predefined Displays the unique serial number of the individual module. The product serial number is encoded in the module firmware. The format of this field is the following: PSAX System Rel. 6.5.0 and later: 12-digit number in the format: YYVVDDnnnnnn, where YY = year of manufacture VV = vendor ID code (manufacturer and location) DD = date code of manufacture (either month or week depending on vendor’s preference) nnnnnn = sequential number, which in conjunction with YY, VV, and DD, creates a unique number for each hardware component in the PSAX product line For existing products with the 10-digit serial number used in Rel. 6.5.0 or later systems, this number is displayed with two preceding zeros. PSAX Rel. 6.3.0 and earlier: 10-digit number. For products with 12-digit serial numbers used in Rel 6.3.0 or earlier systems, the first two digits (YY) are not displayed. Alarm Status Values The Alarm Status field on the Equipment Configuration window is described in Table 3-2. PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 3-6 Release 10.0.0 255-700-584 Chapter 3 Configuring Ports and Channels Using the Console Configuring the Module Table 3-2. Module Alarm Status Descriptions on the Equipment Configuration Window Alarm Status Module Type Affected Description NoAlarm I/O and Server Indicates that no alarms have been detected for the module in this slot. WrongCardType I/O and Server Indicates that one type of module was configured in this slot in the chassis, but a now different module occupies this slot. LineFailed All Hexadecimal format, Example: 12345678ABC I/O and Server Indicates that one or more ports on the module in this slot currently have a loss of signal. The numbers indicate which ports have a loss of signal. For modules that have more than eight ports not receiving signals, the value in this field is in hexadecimal format. CardRemoved All Indicates that the module in this slot is no longer receiving or transmitting signals because the line failed. Indicates that one of the following events occurred: • The module in this slot was configured and then removed from the slot. • Connections on the OC-3, OC-12, STM-1, or STM-4 APS/MSP primary module in this slot were transferred to the standby module. After the transfer occurs, the former primary module then displays CardRemoved in the Alarm Status field; the former standby module then displays Primary in the Status field. ReferenceClockFailed Stratum 3–4 Indicates that the timing reference clock on the Stratum module in this slot failed. CompositeClockFailed Stratum 3–4 Indicates that the timing composite clock on the Stratum module in this slot failed. Overload Power Supply Indicates that the Power Supply module is operating under an overload condition. PowerFailed Power Supply Indicates that the power has failed. Minus48vFailed Power Supply Indicates that the -48 V dc Power Supply module output failed. UnknownAlarm I/O and Server Indicates that the reason for failure is not known. CompleteClockFailed Stratum 3–4 Indicates that the backplane detected a clock error. PowerFailed Indicates that no power is coming into the PSAX chassis. Power Supply Configuring the Module The 21-Port High-Density E1 IMA module has 21 physical E1 ports that may be used for native E1 ATM services or for E1 IMA groups. You must first PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Release 10.0.0 3-7 Chapter 3 Configuring Ports and Channels Using the Console Configuring the Module configure the 21-Port High-Density E1 IMA module before you can set up connection provisioning. The configuration of IMA groups on the 21-Port High-Density E1 IMA module involves the following major tasks: 1. Each port must be configured with the IMA interface, and that IMA interface must be brought into service. 2. Each IMA group must be established. 3. Each IMA group must be configured with an ATM interface (IISP, UNI, or PNNI). Configuring Ports and Channels To configure the 21-Port High-Density E1 IMA ports and channels, perform the following procedure. Configuring the Ports and Channels Begin 1 On the Console Interface Main Menu window (see Figure 3-6), select the Equipment Configuration option and press Enter. Figure 3-6. Console Interface Main Menu Window (Equipment Configuration Selected) The Equipment Configuration window is displayed (see Figure 3-7 and Figure 3-8) . PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 3-8 Release 10.0.0 255-700-584 Chapter 3 Configuring Ports and Channels Using the Console Configuring the Module Figure 3-7. Equipment Configuration Window (As Displayed on the PSAX 1250, PSAX 2300, and PSAX 4500 Console) Figure 3-8. Equipment Configuration Window (As Displayed on the PSAX 1000 Console) PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Release 10.0.0 3-9 Chapter 3 Configuring Ports and Channels Using the Console Configuring the Module 2 On the Equipment Configuration window, select an HD–E1–IMA module in the Card Type column and press Enter. The 21-Port High Density E1 IMA Module Configuration window is displayed (see Figure 3-9). Figure 3-9. 21-Port High Density E1 IMA Module Configuration Window This window allows you to select a physical port (1–21) to configure or the virtual port (22) to configure an IMA group (channel). It also provides the operational status of the ports and channels. Commands The commands in this window have the following functions: Command Bring All Interfaces Into Service Function Brings the out-of-service configured interfaces for all the ports to in-service status. The value InService is displayed in the Oper_Status field for all 21 ports. Take All Interfaces Out Of Service Takes the in-service configured interfaces for all ungrouped ports to out-of-service status. The value OutOfService is displayed in the Oper_Status field for all ungrouped ports. You must use this command first before using the Delete All Interfaces command. PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 3-10 Release 10.0.0 255-700-584 Chapter 3 Configuring Ports and Channels Using the Console Configuring the Module Command Function Delete All Interfaces Deletes the configured interfaces for all ungrouped ports. The value Unconfigured is displayed in the Oper_Status field for all ungrouped ports. Ports that were in groups are no longer grouped but are still configured and in-service. You must first take all interfaces out of service (using the Take All Interfaces Out Of Service command) before you can use this command to delete all the configured interfaces. Use the Take All Interfaces Out Of Service command and the Delete All Interfaces command again to delete the remaining ungrouped ports. The value Unconfigured is displayed in the Oper_Status field for all 21 ports. Update Display Updates the values in the fields to show the most current configuration. Use this command primarily to display the most current information in the Oper_Status field. Go Back to Equipment Configura- Redisplays the Equipment Configuration window. tion 3 Select one of the lines with the physical port you want to configure and press Enter. The 21-Port High Density E1 IMA Module Port and Channel Configuration window is displayed (see Figure 3-10). Figure 3-10. 21-Port High Density E1 IMA Module Port and Channel Configuration Window PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Release 10.0.0 3-11 Chapter 3 Configuring Ports and Channels Using the Console Configuring the Module Commands The commands in this window have the following functions: Command Function Apply Port Configuration For a specified port number value, applies the port configuration field values you set. Reset Port Display Resets the port configuration fields to the last set of saved values. Bring Interface Into Service Brings the selected interface in the Interface Type field for the channel to in-service status. This field is displayed only when the interface is out of service or unconfigured. Take Interface Out Of Service Takes the in-service configured interface to out-of-service status. This field is displayed only when the interface is in service. Configure Interface Displays the screen through which you will configure the applied ATM interface for this port. View Port Statistics Displays the High Density E1 IMA Port Statistics window. Go Back to Card Configuration Redisplays the High Density E1 IMA Card Configuration window. Field Descriptions 4 Select the values for the fields on this window from the values given in Table 3-3. Table 3-3. 21-Port High Density E1 IMA Module Port and Channel Configuration Window Field Descriptions Field Name [Line Type] [Line Coding] Field Value Description Default: Crc-mf Range: N/A Format: Predefined Indicates the framing mode for the port. Crc-mf Indicates that the non-selectable mode is CRC4CAS. The near-end port can receive traffic from the far-end port in this mode or in CCS without time slot 16. Default: Hdb3 Range: N/A Format: Predefined Indicates the type of line coding to be used on this port. (The data format that lets either end of the communications channel correctly interpret messages from the other.) Hdb3 High-density bipolar of order 3. A bipolar coding method that does not allow more than 3 consecutive zeros. Ami Alternate mark inversion. Indicates zero code suppression. PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 3-12 Release 10.0.0 255-700-584 Chapter 3 Configuring Ports and Channels Using the Console Configuring the Module Table 3-3. 21-Port High Density E1 IMA Module Port and Channel Configuration Window Field Descriptions (Continued) Field Name Loopback Transmit Clock [Time Slot 16] [Line Status] Field Value Description Default: NoLoop Range: N/A Format: Predefined Indicates whether the port is to be used for loopback testing and, if so, the type of loopback to be performed. NoLoop The port will not be used for loopback. LocalLoop Local loopback will be used on this port. The signal will be received from another module in the chassis, sent through the module circuitry (including the segmentation and reassembly (SAR) function) and the chassis backplane to the originating module. LineLoop Line loop will be used on this port. The received signal will be sent through the receiver and the line driver, and then back out to the originating point. TestMode Not supported. Default: LocalTiming Range: N/A Format: Predefined Indicates what type of synchronization is used by the interface to maintain proper data flow through the PSAX system and the remote devices connected to the system. LocalTiming Selects a synchronization source (CompositeClock, T1BITS, E1ETSI, CompositeClockDS0A, Freerun, or LineTiming) that is provided through the Stratum 3–4 module. LoopTiming Selects the recovered clock from the received data and is used as the transmit clock on the selected interface. Adaptive Timing Selects an interface buffer to allow different data rates to pass through the PSAX system and prevent overruns or underruns in the traffic. This option is displayed when the port is configured as Unstructured in the Data Transfer Type field. Default: Cas Range: N/A Format: Predefined Indicates that Time Slot 16 is reserved for network use and not available for ATM payload. Cas Indicates that Time Slot 16 is reserved for network use. Default: NoAlarm Range: N/A Format: Predefined Indicates the line status of the port: loopback, failure, received and transmitted alarm information. See the table below for descriptions. PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Release 10.0.0 3-13 Chapter 3 Configuring Ports and Channels Using the Console Configuring the Module Table 3-3. 21-Port High Density E1 IMA Module Port and Channel Configuration Window Field Descriptions (Continued) Field Name Interface Type [Admin Status] Field Value Description Default: Unconfigured Range: N/A Format: Predefined Indicates the type of end-to-end connection protocol that governs the transmission parameters of this configured port and channel interface. Unconfigured This interface is not configured. Atm Ima This interface is configured as an ATM IMA interface. Note: Each port in an IMA group must first be configured as an IMA interface. AtmUni3-0 This interface is configured for the ATM UNI 3.0 interface. AtmUni3-1 This interface is configured for the ATM UNI 3.1 interface. AtmUni4-0 This interface is configured for the ATM UNI 4.0 interface. AtmPnni1_0 This interface is configured for the ATM PNNI 1.0 interface. IispUser This interface is configured for the ATM IISP user interface. IispNetwork This interface is configured for the ATM IISP network interface. Default: Unconfigured Range: N/A Format: Predefined Indicates the administrative status of the port. Unconfigured The interface for the port is not configured. OutOfService The interface has not yet been brought into service, or in-service interface has been set to out of service with the Take Interface Out of Service command. InService The interface has been brought into service with the Bring Interface Into Service command. PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 3-14 Release 10.0.0 255-700-584 Chapter 3 Configuring Ports and Channels Using the Console Configuring the Module Table 3-3. 21-Port High Density E1 IMA Module Port and Channel Configuration Window Field Descriptions (Continued) Field Name [Oper Status] Field Value Description Default: Unconfigured Range: N/A Format: Predefined Indicates the operational status of the port and whether the port is exchanging a valid signal. Unconfigured This channel is not operational because the interface is not configured. OutOfService Two types of problems cause this status. • A loss-of-signal condition is due to any one of the following: ~ The module port is not physically connected to a cable. ~ The cable is not connected at the other end to a device. ~ The cable is broken. • A loss of frame or encoding is due to a problem with the framing or encoding of the signal. For example, a repeater could corrupt the signal. InService The port is physically connected to a cable, the cable is conducting the signal, and the signal is being transmitted and received correctly. Table 3-4 provides the line status alarm descriptions for the 21-Port HighDensity E1 IMA module. This alarm is displayed in the Line Status field on the High Density E1 IMA Port and Channel Configuration window. Table 3-4. 21-Port High-Density E1 IMA Module—Line Status Alarm Descriptions Alarm Description NoAlarm No alarm is present. RcvFarEndLOF Far-end sending loss of frame. FarEndLOF Near-end sending loss of frame indication. RcvAIS Far-end sending alarm indication signal. AIS Near-end sending alarm indication signal. LossOfFrame Near-end loss of frame. LossOfSignal Near-end loss of signal. LoopbackState Near-end is looped. T16AIS Near-end sending E1 TS16 alarm indication signal. RcvFarEndLOMF Far-end sending TS16 loss of multi-frame. FarEndLOMF Near-end sending TS16 loss of multi-frame. PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Release 10.0.0 3-15 Chapter 3 Configuring Ports and Channels Using the Console Configuring the Module Table 3-4. 21-Port High-Density E1 IMA Module—Line Status Alarm Descriptions Alarm Description RcvTestCode Near-end detects a test code. OtherFailure Any line status not defined here. RmtLoopback Far-end loopback. 5 To apply the values for the port fields, select the Apply Port Configuration command. 6 Select the Configure Interface command. The selected interface configuration window is displayed. See the PacketStar® PSAX Connections Provisioning Guide for instructions. 7 To bring the interface into service, select the Bring Interface Into Service command. Note: You must bring the ATM IMA interface into service before you can set up High-Density E1 IMA groups. End Viewing Port Statistics Begin To view statistics for a port, from the 21-Port High Density E1 IMA Module Port and Channel Configuration window (Figure 3-10), select the View Port Statistics command. The 21-Port High Density E1 IMA Port Statistics window (see Figure 3-11) is displayed. PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 3-16 Release 10.0.0 255-700-584 Chapter 3 Configuring Ports and Channels Using the Console Configuring the Module Figure 3-11. 21-Port High Density E1 IMA Port Statistics Window Commands The commands in this window have the following functions: Command Function Continuous Update Updates the values in the fields every second. Reset Statistics Sets all field values to zero. Go Back to Port Configuration Redisplays the High Density E1 IMA Port and Channel Configuration window. Field Descriptions Descriptions of the data fields for the High Density E1 IMA Port Statistics window are given in Table 3-5. PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Release 10.0.0 3-17 Chapter 3 Configuring Ports and Channels Using the Console Configuring the Module Table 3-5. 21-Port High Density E1 IMA Port Statistics Window Field Descriptions Field Name Field Value Description Errored Seconds Default: 0000000000 A count of the number of errored seconds that have occurred on the E1 port since the last time Range: N/A statistics were reset. An errored second contains Format: Numeric at least one of the following: • Path coding violations • Controlled slip events • A detected alarm indication signal (AIS) defect • Presence of bipolar violations Severely Errored Seconds Default: 0000000000 A count of the number of severely errored seconds that have occurred on the E1 port since the Range: N/A last time statistics were reset. A severely errored Format: Numeric second contains at least one of the following: • 320 or more path coding violation error events • Out-of-frame (OOF) defects • Detected AIS defect • A minimum of 1,544 line coding violations (LCVs). Severely Errored Framing Seconds Default: 0000000000 A count of the number of severely errored framing seconds encountered by the E1 port in one of Range: N/A the previous 96 individual 15-minute intervals. A Format: Numeric severely errored framing second has one or more out-of-frame defects or a detected AIS defect. Unavailable Seconds Default: 0000000000 A count of the number of unavailable seconds encountered by the E1 port in one of the previRange: N/A ous 96 individual 15-minute intervals. UnavailFormat: Numeric able seconds (UAS) are calculated by the number of seconds that the interface is unavailable. Controlled Slip Sec- Default: 0000000000 A count of the number of controlled slip seconds onds encountered by the E1 port in the previous Range: N/A 24-hour period. A controlled slip second is a Format: Numeric 1-second interval containing one or more controlled slip events. Path Coding Violations Default: 0000000000 A count of the number of path coding violations encountered by the E1 port in the previous Range: N/A 24-hour period. A path coding violation is a Format: Numeric frame synchronization bit error in the E1-no-CRC formats, or a CRC error in the E1-CRC formats. PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 3-18 Release 10.0.0 255-700-584 Chapter 3 Configuring Ports and Channels Using the Console Configuring the Module Table 3-5. 21-Port High Density E1 IMA Port Statistics Window Field Descriptions Field Name Line Errored Seconds Field Value Description Default: 0000000000 A count of the number of line errored seconds encountered by the E1 port in the previous Range: N/A 24-hour period. A line errored second is a second Format: Numeric in which one or more line code violation error events were detected. Bursty Errored Sec- Default: 0000000000 A count of the number of bursty errored seconds onds encountered by the E1 port in the previous Range: N/A 24-hour period. A bursty errored second has Format: Numeric fewer than 320 and more than 1 path coding violation error events, no severely errored frame defects, and no detected incoming AIS defects. Line Coding Violations Default: 0000000000 A count of the number of line coding violations that have occurred on the E1 port since the last Range: N/A time statistics were reset. Line coding violations Format: Numeric indicate that a bipolar violation or an excessive zeroes error event has occurred. Configuring IMA Groups Once you have configured ports with ATM IMA interfaces, you can set up High-Density E1 IMA groups for the 21-Port High-Density E1 IMA module. High-Density E1 IMA groups must be defined on the virtual port (port 22). Up to 10 groups (channels) can be configured on this port. A group may have 1 to 21 of the physical ports assigned to it. For example: ~ You can assign all 21 of the physical ports to Group 1 (channel 1); however 9 groups would be unused. ~ You can assign one physical port to Group 1(channel 1) and any combination in Group 2 (channel 2) through Group 10 (channel 10) totalling 10 groups and 21 ports. Figure 3-12 illustrates these options. 1 21 Physical Ports Groups 1 2 3 4 5 6 7 8 9 10 Channels Virtual Port 22 1-21 physical ports can be assigned to any one group (channel) or in any combination totalling 10 groups and 21 ports. Figure 3-12. High-Density E1 IMA Group Configuration Options PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Release 10.0.0 3-19 Chapter 3 Configuring Ports and Channels Using the Console Configuring the Module Perform the following procedure to set up High-Density E1 IMA groups. Setting Up High-Density E1 IMA Groups Begin 1 On the 21-Port High Density E1 IMA Module Configuration window (see Figure 3-9), select port 22, which is the virtual port, and press Enter. The IMA Virtual Group Channel Configuration window is displayed (see Figure 3-13). Figure 3-13. IMA Virtual Group Channel Configuration Window Commands The commands in this window have the following functions: Command Function Bring Interfaces Into Service Brings out-of-service configured interfaces to in-service status. You must first configure the interface before you can use this command. Take Interfaces Out of Service Takes the in-service configured interfaces to out-ofservice status. You must use this command first before using the Delete All Interfaces command. PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 3-20 Release 10.0.0 255-700-584 Chapter 3 Configuring Ports and Channels Using the Console Configuring the Module Command Function Delete All Interfaces Deletes all interfaces for all ports. The value Unconfigured is displayed in the Interface, Admin. Status, and Oper. Status fields for all groups. All values are cleared in the Ports field. Only the interfaces that are out of service can be unconfigured by this command. Go Back to Card Config Redisplays the 21-Port High Density E1 IMA Module Configuration window. Field Descriptions The display-only fields in this window are described in Table 3-6. Table 3-6. IMA Virtual Group Channel Configuration Window Field Descriptions Field Name Interface (display only) Admin. Status (display only) Field Value Description Default: Unconfigured Range: N/A Format: Predefined Displays the ATM interface type applied to the group (1-10). The interface type is applied in the next window, IMA Group Configuration. Unconfigured Indicates that this interface is not configured. AtmUni 3-0 Indicates that this interface is configured for ATM UNI 3.0 interface. AtmUni 3-1 Indicates that this interface is configured for ATM UNI 3.1 interface. AtmUni 4-0 Indicates that this interface is configured for ATM UNI 4.0 interface. IispUser Indicates that this interface is configured for ATM IISP User interface. IispNetwork Indicates that this interface is configured for ATM IISP Network interface. AtmPnni 1-0 Indicates that this interface is configured for ATM ATM PNNI 1.0 interface. Default: Unconfigured Range: N/A Format: Predefined Displays the administrative status of the group (1-10). Unconfigured Indicates that the interface for the group is not configured. OutOfService Indicates that the interface has not yet been brought into service, or its in-service interface has been set to out of service with the Take Interfaces Out of Service command InService The interface has been brought into service with the Bring Interfaces Into Service command. PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Release 10.0.0 3-21 Chapter 3 Configuring Ports and Channels Using the Console Configuring the Module Table 3-6. IMA Virtual Group Channel Configuration Window Field Descriptions (Continued) Field Name Oper. Status (display only) Ports (display only) Field Value Description Default: Unconfigured Range: N/A Format: Predefined Displays the operational status of the group and whether the group is exchanging a valid signal. Unconfigured Indicates that this channel is not operational because the interface is not configured. OutOfService Indicates that the group (near end and far end) is not operational because there is no connection. InService Indicates that the group (near end and far end) is operational. Default: N/A Range: 1-21 Format: Numeric Displays each port assigned to the group. Ports are assigned on the next window, IMA Group Configuration. 2 Select the first line for group 1 and press Enter. The IMA Group Configuration window (see Figure 3-14) is displayed. Figure 3-14. IMA Group Configuration Window Commands The commands in this window have the following functions: Command Function Apply IMA Group Configuration Applies the configuration field values you set. Reset IMA Group Display Resets the port configuration display. PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 3-22 Release 10.0.0 255-700-584 Chapter 3 Configuring Ports and Channels Using the Console Configuring the Module Command Function Bring Interface Into Service Brings the out-of-service configured interface for the channel to in-service administrative status. You must first configure the interface before you can use this command. This command is displayed only when the interface is out of service. Take Interface Out Of Service Takes the in-service configured interface to out-ofservice administrative status. You must use this command first before using the Delete All Interfaces command. This command is displayed only when the interface is in service. Configure Interface Displays the screen through which you will configure the applied ATM interface for this group. View IMA Group Statistics Displays the IMA Group Channel Statistics window. Go Back to Channel Config Redisplays the IMA Virtual Group Channel Configuration window. Field Descriptions 3 Select the values for the fields on this window from the values given in Table 3-7. Table 3-7. IMA Group Configuration Window Field Descriptions Field Name Field Value Description Minimum Tx Links Default: 1 Range: 1–21 Format: Numeric Indicates the minimum number of transmit links required to be active for the IMA group to be in the up state. Minimum Rx Links Default: 1 Range: 1–21 Format: Numeric Indicates the minimum number of receive links required to be active for the IMA group to be in the up state. PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Release 10.0.0 3-23 Chapter 3 Configuring Ports and Channels Using the Console Configuring the Module Table 3-7. IMA Group Configuration Window Field Descriptions Field Name Near-end Tx Clock Field Value Description Default: Ctc Range: N/A Format: Predefined Indicates the transmit clocking mode used by the near-end IMA group. Ctc Specifies that the Common Transmit Clock (CTC) mode will be used by the near-end IMA group. Select this value only if the transmit clock of all IMA links in this group will be derived from the same source. You must set up the underlying clock configuration to ensure operation in the selected mode. Itc Specifies that the Independent Transmit Clock (ITC) mode will be used by the near-end IMA group. Select this value only if there will be at least one IMA link in this group whose transmit clock will be derived from a source that is different from at least one other link transmit clock. The ITC mode allows links to have different clock sources but does not require it. Tx IMA Id Default: N/A Range: 0–255 Format: Numeric Indicates the IMA identifier to be used by the farend IMA function. The Tx IMA Id is an identifier used to distinguish this IMA group from other IMA groups in a connection. Choose a unique value within the range of 0–255; it does not have to be the same as that of the far-end IMA group. Tx Frame Length Default: M128 Range: N/A Format: Predefined Indicates the frame length to be used by the IMA group in the transmit direction. This can be set only when the IMA group is configured. The frame length is the number of cells in each IMA frame. Use the smaller number (e.g. m32) to send more IMA frames and use the larger number (e.g. m256) to send fewer IMA frames. Smaller frames handle errors more quickly, but the larger frames result in less overhead. M32 The frame length is M32 cells. M64 The frame length is M64 cells. M128 The frame length is M128 cells. M256 The frame length is M256 cells. Default: 25 Range: 1-200 Format: Numeric Indicates the maximum number of milliseconds of delay differential among the links that will be tolerated. Link Delay Diff PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 3-24 Release 10.0.0 255-700-584 Chapter 3 Configuring Ports and Channels Using the Console Configuring the Module Table 3-7. IMA Group Configuration Window Field Descriptions Field Name Field Value Compatibility Mode Default: No Range: N/A Format: Predefined Auto IMAversion Detection Preferred IMAversion Description Allows the near-end IMA group to receive the link status at the correct location in the IMA control protocol (ICP) cell from the far-end IMA group. This mode must be set correctly when connected to ATM IMA Specification Version 1.0 equipment. The Compatibility Mode field must be enabled when connected to equipment following the alternate link state reporting mechanism described in Appendix C.8.1 of ATM IMA Specification Version 1.1. No Disables the Compatibility Mode. Yes Enables the Compatibility Mode. Default: Enabled Range: N/A Format: Predefined Indicates whether the IMA group will automatically select the compatible ATM IMA Specification (Version 1.0 or Version 1.1) for both ends of a link or only use the configured preferred ATM IMA Specification version. Enabled Indicates that the IMA group will automatically select the compatible ATM IMA Specification version for both ends of a link. Disabled Indicates that the IMA group will only use the configured preferred ATM IMA Specification version in the Preferred IMAversion field. Default: Version1p1 Displays the preferred ATM IMA Specification version. Range: N/A Format: Predefined Version1p1 Indicates that the preferred ATM IMA Specification is Version 1.1. Version1p0 Indicates that the preferred ATM IMA Specification is Version 1.0. Alpha Value Default: 2 Range: 1-2 Format: Numeric Indicates the alpha value used to specify the number of consecutive invalid IMA control protocol (ICP) cells to be detected before moving to the IMA HUNT state. The smaller the value, the faster the IMA link will go into a loss of IMA frame (LIF) failure state. Beta Value Default: 2 Range: 1-5 Format: Numeric Indicates the beta value used to specify the number of consecutive errored ICP cells to be detected before moving to the IMA HUNT state. The smaller the value, the faster the IMA link will go into an LIF failure state. PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Release 10.0.0 3-25 Chapter 3 Configuring Ports and Channels Using the Console Configuring the Module Table 3-7. IMA Group Configuration Window Field Descriptions Field Name Gamma Value Field Value Default: 1 Range: 1-5 Format: Numeric [Far-end Tx Clock] Default: Ctc Range: N/A Format: Predefined [Rx IMA ID] Description Indicates the gamma value used to specify the number of consecutive valid ICP cells to be detected before moving from the IMA PRESYNC state to the IMA SYNC state. The smaller the value, the faster the IMA link will recover from an LIF error. Displays the transmit clocking mode used by the far-end IMA group. Ctc Specifies that the Common Transmit Clock (CTC) mode will be used by the far-end IMA group. Itc Specifies that the Independent Transmit Clock (ITC) mode will be used by the far-end IMA group. Default: 0 Range: 0-255 Format: Numeric Displays the IMA identifier currently in use by the far-end IMA function. The Rx IMA Id is an identifier used to distinguish this IMA group from other IMA groups in a connection. [Rx Frame Length] Default: M32 Range: N/A Format: Predefined Displays the IMA frame length in cells as received from the remote IMA function. M32 The frame length is M32 cells. M64 The frame length is M64 cells. M128 The frame length is M128 cells. M256 The frame length is M256 cells. [Least Delay Link] Default: Port 0 Range: 0-21 Format: Numeric Displays the interface index of the link configured in the IMA group that has the smallest link propagation delay. This value has meaning only if more than one link has been configured in the IMA group. [Max Delay Diff] Default: 1 Range: N/A Format: Numeric Displays the observed number of milliseconds of delay differential among the links. PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 3-26 Release 10.0.0 255-700-584 Chapter 3 Configuring Ports and Channels Using the Console Configuring the Module Table 3-7. IMA Group Configuration Window Field Descriptions Field Name Interface Type [Admin Status] [Oper Status] Field Value Description Default: Unconfigured Range: N/A Format: Predefined Indicates the type of end-to-end connection protocol that governs the transmission parameters of the configured channel interface. An interface type can be configured only if a port exists in the group. Unconfigured This interface is not configured. AtmUni3-0 This interface is configured for the ATM UNI 3.0 interface. AtmUni3-1 This interface is configured for the ATM UNI 3.1 interface. AtmUni4-0 This interface is configured for the ATM UNI 4.0 interface. IispUser This interface is configured for the ATM IISP user interface. IispNetwork This interface is configured for the ATM IISP network interface. AtmPnni1-0 This interface is configured for the ATM PNNI 1.0 interface. Default: Unconfigured Range: N/A Format: Predefined Displays the administrative status of the port. Unconfigured The interface for the port is not configured. OutOfService The interface has not yet been brought into service, or its in-service interface has been set to out of service with the Take Interface Out of Service command. InService The interface has been brought into service with the Bring Interface Into Service command. Default: Unconfigured Range: N/A Format: Predefined Displays the operational status of the port and whether the port is exchanging a valid signal. Unconfigured This channel is not operational because the interface is not configured. OutOfService The group (near end and far end) is not operational because there is no connection. InService The group (near end and far end) is operational. PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Release 10.0.0 3-27 Chapter 3 Configuring Ports and Channels Using the Console Configuring the Module Table 3-7. IMA Group Configuration Window Field Descriptions Field Name [Near-end State] Field Value Description Default: NotConfig- Displays the current operational state of the nearured end IMA group state machine. Range: N/A Format: Predefined NotConfigured The group does not exist. StartUp The near end is in start-up and is waiting to receive the indication that the far end is in startup. StartUpAck When both groups start up, they move through this transitional state to the InsufficientLinks state. While in this state, indications from the near end that it is in start-up are ignored. CfgAbt Configuration aborted. This state is entered when the near end tries to use the following unacceptable configuration parameters (remaining fields below). UnsupportedM Unsupported value of M (M = frame length). CfgAbtIncSymmetry Incompatible group symmetry. CfgAbtOther Configuration aborted for other reasons. InsufficientLinks This state implies that the group has accepted the near-end group parameters and that the near end has also accepted its own group parameters, but does not have sufficient links to move into the Operational state. Blocked The group is blocked (e.g., inhibited by Unit Management (UM)). The group can be blocked for maintenance purposes while sufficient links are Active in both directions. The PSAX group is blocked when it is administratively out of service. Operational The group is operational and in the Up state. The group is not inhibited and has sufficient links in both the Tx and Rx directions. The IMA interface now has the capability to receive ATM layer cells and pass them from the IMA sublayer to the ATM layer. PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 3-28 Release 10.0.0 255-700-584 Chapter 3 Configuring Ports and Channels Using the Console Configuring the Module Table 3-7. IMA Group Configuration Window Field Descriptions Field Name [Far-end State] Field Value Description Default: NotConfig- Displays the current operational state of the farured end IMA group state machine. Range: N/A Format: Predefined NotConfigured The group does not exist. StartUp The far end is in start-up and is waiting to receive the indication that the near end is in start-up. StartUpAck When both groups start up, they move through this transitional state to the InsufficientLinks state. While in this state, indications from the near end that it is in start-up are ignored. CfgAbt Configuration aborted. This state is entered when the far end tries to use the following unacceptable configuration parameters (remaining fields below). UnsupportedM Unsupported value of M (M = frame length). CfgAbtIncSymmetry Incompatible group symmetry. CfgAbtOther Configuration aborted for other reasons. InsufficientLinks This state implies that the group has accepted the far-end group parameters and that the far end has also accepted its own group parameters, but does not have sufficient links to move into the Operational state. Blocked The group is blocked (e.g., inhibited by the Unit Management (UM)). The group can be blocked for maintenance purposes while sufficient links are Active in both directions. Operational The group is operational and in the Up state. The group is not inhibited and has sufficient links in both the Tx and Rx directions. The IMA interface now has the capability to receive ATM layer cells and pass them from the IMA sublayer to the ATM layer. PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Release 10.0.0 3-29 Chapter 3 Configuring Ports and Channels Using the Console Configuring the Module Table 3-7. IMA Group Configuration Window Field Descriptions Field Name [Failure Status] Field Value Description Default: NoFailure Range: N/A Format: Predefined Displays the current failure status of the IMA group, which gives the reason why the group state machine is in the Down state. This means that either the near end or the far end is not operational. See the Near-end State and Far-end State field values above. NoFailure The IMA group state machine is Up and in the Operational state. StartUpNe The near end is in the StartUp state. StartUpFe The far end is in the StartUp state. InvalidMValueNe The near end has received an invalid M value (M = frame length). InvalidMValueFe The far end has received an invalid M value (M = frame length). FailedAsymmetricNe The near end is reporting that the far end is requesting a group symmetry that the near end does not support. FailedAsymmetricFe The far end is not accepting near-end symmetry. InsuffLinksNe The near end does not have sufficient links to move into the Operational state. InsuffLinksFe The far end does not have sufficient links to move into the Operational state. BlockedNe The group is blocked at the near end. BlockedFe The group is blocked at the far end. OtherFailure The group has failed for other reasons. PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 3-30 Release 10.0.0 255-700-584 Chapter 3 Configuring Ports and Channels Using the Console Configuring the Module Table 3-7. IMA Group Configuration Window Field Descriptions Field Name [GroupSymmetry] In. Av. Field Value Description Default: SymOpera- Displays the mode that allows symmetric or tion asymmetric cell rate transfer over the IMA virtual link. Range: N/A/ Format: Predefined SymOperation The IMA group is only required to carry ATM layer cells on physical links in which the IMA links in both the transmit and receive directions are Active. AsymOperation The IMA group is allowed to carry ATM traffic over the physical links on which the IMA links in both the transmit and receive directions are not Active at the same time. AsymConfiguration The IMA group is not required to configure IMA links in both directions of the physical links used by the IMA unit. Default: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Range: 1–21 Format: Numeric Displays the ports that are available (in this case, the first 20 of 21) to be included in a group. To select a port, navigate to a number in the lower, Av. (available) row and press Enter. The number moves to the upper, In. (in group) row. To select more ports, use the >> navigation key to go to the next page and the << navigation key to go to the previous page.You may select 1 to 21 ports to make a group. 4 Select the Apply IMA Group Configuration command. The port configuration is applied. 5 Select the Configure Interface command. The selected interface type window is displayed. See the PacketStar® PSAX Connections Provisioning Guide for instructions. 6 Select the Bring Interface Into Service command. The selected interface is administratively in service. The [Admin Status] field displays the InService value. 7 Repeat steps 1–6 under ”Setting Up High-Density E1 IMA Groups” on page 3-20 for the remaining nine IMA groups, as needed. All 21 physical ports may belong to one group. End PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Release 10.0.0 3-31 Chapter 3 Configuring Ports and Channels Using the Console Configuring the Module Viewing Group Channel Statistics Begin To view statistics for a group, from the IMA Group Configuration window (Figure 3-14), select the View IMA Group Statistics command. The IMA Group Channel Statistics window (see Figure 3-15) is displayed. Figure 3-15. IMA Group Channel Statistics Window Commands The commands in this window have the following functions: Command Function Continuous Update Updates the field values every second. Reset Statistics Sets all field values to zero. Go Back to Group Channel Configuration Redisplays the IMA Group Configuration window. Field Descriptions Descriptions of the data fields for this window are given in Table 3-8. PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 3-32 Release 10.0.0 255-700-584 Chapter 3 Configuring Ports and Channels Using the Console Saving the Equipment Configuration and Logging Off Table 3-8. IMA Group Channel Statistics Window Field Descriptions Field Name Field Value Description [Near-End Failures] Default: 0 Range: N/A Format: Numeric Displays the number of failures at the transmitting end of the link. [Far-End Failures] Default: 0 Range: N/A Format: Numeric Displays the number of failures at the receiving end of the link. [Number of Active Tx Links] Default: 0 Range: 0–21 Format: Numeric Displays the number of active transmit links from the near end. [Number of Active Rx Link] Default: 0 Range: 0–21 Format: Numeric Displays the number of active receive links from the far end. [Time Elapsed] Default: 0:00:00 Range: N/A Format: hh:mm:ss Displays the time elapsed in hours, minutes, and seconds since last reset. Saving the Equipment Configuration and Logging Off After configuring the module ports and channels, the interface types for each port and channel, and the connections, you must save the values to the PSAX system database. It is recommended that you save your values frequently as you progress through your work, at a minimum, after finishing each stage of work: • Configuring each module in your system • Configuring the connections in your system • Before exiting your current console session Perform the following procedure to permanently save the values for your system. ! CAUTION: If your system loses power or if you reboot the chassis, and you have not yet saved the values permanently, you will lose all unsaved values you have applied on the various windows. Begin 1 Press Ctrl+G, to return to the Console Interface Main Menu window. PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Release 10.0.0 3-33 Chapter 3 Configuring Ports and Channels Using the Console Saving the Equipment Configuration and Logging Off On the Console Interface Main Menu window, [Modified] is displayed next to the Save Configuration command, indicating you have made changes to the system that are not yet saved to the PSAX system database (see Figure 3-16). Figure 3-16. Save Configuration [Modified] (Before Saving) 2 Select the Save Configuration command or press Ctrl+A. Wait a few seconds while the system writes the values to the PSAX system database. The system displays the following message while it is executing this command: Saving the equipment and connection information Note: In PSAX systems with redundant CPUn modules, the standby CPUn module reboots every time you save the configuration on the primary CPUn module. This event is a function of the SVC retention feature and the result of saving the configuration changes you have made. When the save configuration function is completed, the system displays an appropriate message as described in Table 3-9. PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 3-34 Release 10.0.0 255-700-584 Chapter 3 Configuring Ports and Channels Using the Console Provisioning Connections Table 3-9. Messages Generated after the Save Configuration Process When a PSAX system is... the system displays... nonredundant T-SaveConfiguration: saveConfigurationReasonCode=All-OK redundant T-SaveConfiguration: saveConfigurationReasonCode = Expect2ndCPUCardFailedOrRemoved* The standby CPUn module is rebooted when the save command is issued. After the standby CPUn module reboots, the system displays the following message: T-SaveConfiguration: saveConfigurationReasonCode=FileTransferCompleted * This message indicates that while the standby CPUn module reboots after you select the Save ration command, the standby CPUn module is temporarily unavailable. Configu- After saving the configuration values, the indicator [Modified] is no longer displayed next to the Save Configuration command. End Provisioning Connections For instructions on configuring interfaces and provisioning connections, see your PacketStar® PSAX Connections Provisioning Guide. In using that guide, keep in mind that the following connection types are supported by the 21-Port High-Density E1 IMA module: • PVC connections: ~ ATM-to-ATM virtual channel connection (VCC) ~ ATM-to-ATM virtual path connection (VPC) ~ Bridge-to-ATM virtual channel connection (VCC) (z) ~ Circuit Emulation-to ATM virtual channel connection (VCC) ~ Variable bit rate (VBR)-to-ATM virtual channel connection (VCC) ~ AAL2 Trunk Connection (w) • SVC connections: ~ ATM-to-ATM virtual channel connection VCC (n) ~ ATM IISP CBR connection ~ ATM IISP VBR connection • SPVC connections: ~ ATM-to-ATM virtual channel connection (VCC) (z) ~ Circuit Emulation-to-ATM virtual channel connection (VCC) (y) ~ Circuit Emulation-to-ATM Std AAL2 virtual channel connection (VCC) ~ Variable bit rate (VBR)-to-ATM virtual channel connection (VCC) (w) PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Release 10.0.0 3-35 Chapter 3 Configuring Ports and Channels Using the Console Provisioning Connections PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 3-36 Release 10.0.0 255-700-584 A Pin Configurations Overview of This Appendix This appendix describes the connector pin assignments for the 21-Port High-Density E1 IMA module. Connector Pin Assignments The 21-Port High-Density E1 IMA module provides two 50-pin Mini-Champ connectors(see Figure A-1) labeled PORTS 1-12 and PORTS 13-21. The following sections show the pin assignments between these connectors, the Lucent cable, and the patch panel connectors. 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 Figure A-1. Pin Locations on the Mini-Champ Connector To the PSAX 12-Port BNC Patch Panel Table A-1 lists the pin assignments between the 21-Port High-Density E1 IMA module connectors, the Lucent cable, and the 50-pin RJ-48H connector and the BNC connectors on the PSAX 12-Port BNC Patch Panel. PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Release 10.0.0 A-1 Appendix A Pin Configurations Connector Pin Assignments Table A-1. 21-Port High-Density E1 IMA Module Connector, Cable, and PSAX 12-Port BNC Patch Panel Pin Assignments Module Connectors1 Port2 1/13 2/14 3/15 4/16 5/17 6/18 7/19 8/20 Signal Name Socket Pin #3 Lucent Cable (COMCODE 300550639) Mini Champ RJ-48H Plug P1 Socket P2 TX-T 27 27 26 2 TX-R 2 2 1 27 RX-T 1 1 39 1 RX-R 26 26 14 26 TX-T 29 29 27 4 TX-R 4 4 2 29 RX-T 3 3 40 3 RX-R 28 28 15 28 TX-T 31 31 28 6 TX-R 6 6 3 31 RX-T 5 5 41 5 RX-R 30 30 16 30 TX-T 33 33 29 8 TX-R 8 8 4 33 RX-T 7 7 42 7 RX-R 32 32 17 32 TX-T 35 35 30 10 TX-R 10 10 5 35 RX-T 9 9 43 9 RX-R 34 34 18 34 TX-T 37 37 31 12 TX-R 12 12 6 37 RX-T 11 11 44 11 RX-R 36 36 19 36 TX-T 40 40 32 15 TX-R 15 15 7 40 RX-T 14 14 45 14 RX-R 39 39 20 39 TX-T 42 42 33 17 TX-R 17 17 8 42 RX-T 16 16 46 16 RX-R 41 41 21 41 PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 A-2 PSAX 12-Port BNC Patch Panel RJ-48H Plug BNC ConnecPin # tor TX1 RX1 TX1 RX1 TX1 RX1 TX1 RX1 TX1 RX1 TX1 RX1 TX1 RX1 TX1 RX1 Release 10.0.0 255-700-584 Appendix A Pin Configurations Connector Pin Assignments Table A-1. 21-Port High-Density E1 IMA Module Connector, Cable, and PSAX 12-Port BNC Patch Panel Pin Assignments (Continued) Module Connectors1 Port2 Signal Name Socket Pin #3 9/21 10/NC 4 11/NC 12/NC Lucent Cable (COMCODE 300550639) Mini Champ RJ-48H Plug P1 Socket P2 PSAX 12-Port BNC Patch Panel RJ-48H Plug BNC ConnecPin # tor TX-T 44 44 34 19 TX-R 19 19 9 44 RX-T 18 18 47 18 RX-R 43 43 22 43 TX-T 46 46 35 21 TX-R 21 21 10 46 RX-T 20 20 48 20 RX-R 45 45 23 45 TX-T 48 48 36 23 TX-R 23 23 11 48 RX-T 22 22 49 22 RX-R 47 47 24 47 TX-T 50 50 37 25 TX-R 25 25 12 50 RX-T 24 24 50 24 RX-R 49 49 25 49 TX1 RX1 TX1 RX1 TX1 RX1 TX1 RX1 1 For 21-port E1 modules, one module requires two PSAX 12-Port BNC Patch Panels. 2 Indicates port numbers from the module connectors and through the patch panel. 3 Pins 13 and 38 are not used by the module. On the patch panel, the RJ-48H connector is labeled PORT and match with the BNC connectors labeled 1–12. 1–12, 4 NC = not connected at the module. To the PSAX 24-Port RJ Patch Panel Table A-1 lists the pin assignments between the 21-Port High-Density E1 IMA module connectors, the Lucent cable, and the PSAX 24-Port RJ Patch Panel connectors, two 50-pin Cinch plugs and the 24 RJ-48C sockets. Note: The transmit and receive—tip and ring—pairs of the patch panel RJ-48C sockets are reversed from the standard RJ-48C pin assignments described in the ANSI T1.403 standard (Pin 1 R1, Pin 2 T1, Pin 4 R, and Pin 5 T). PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Release 10.0.0 A-3 Appendix A Pin Configurations Connector Pin Assignments Table A-1. 21-Port High-Density E1 IMA Module Module Connector, Cable, and PSAX 24-Port RJ Patch Panel Pin Assignments Lucent Cable (COMCODE 300550639) Module Connectors1 Port2 1/13 2/14 3/15 4/16 5/17 6/18 7/19 8/20 Signal Name Socket Pin #3 Mini Champ Plug P1 RJ-48H Socket P2 RX-T 1 1 39 39 1 (T1) RX-R 26 26 14 14 2 (R1) TX-T 27 27 26 26 4 (T) TX-R 2 2 1 1 5 (R) RX-T 3 3 40 40 1 (T1) RX-R 28 28 15 15 2 (R1) TX-T 29 29 27 27 4 (T) TX-R 4 4 2 2 5 (R) RX-T 5 5 41 41 1 (T1) RX-R 30 30 16 16 2 (R1) TX-T 31 31 28 28 4 (T) TX-R 6 6 3 3 5 (R) RX-T 7 7 42 42 1 (T1) RX-R 32 32 17 17 2 (R1) TX-T 33 33 29 29 4 (T) TX-R 8 8 4 4 5 (R) RX-T 9 9 43 43 1 (T1) RX-R 34 34 18 18 2 (R1) TX-T 35 35 30 30 4 (T) TX-R 10 10 5 5 5 (R) RX-T 11 11 44 44 1 (T1) RX-R 36 36 19 19 2 (R1) TX-T 37 37 31 31 4 (T) TX-R 12 12 6 6 5 (R) RX-T 14 14 45 45 1 (T1) RX-R 39 39 20 20 2 (R1) TX-T 40 40 32 32 4 (T) TX-R 15 15 7 7 5 (R) RX-T 16 16 46 46 1 (T1) RX-R 41 41 21 21 2 (R1) TX-T 42 42 33 33 4 (T) TX-R 17 17 8 8 5 (R) PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 A-4 PSAX 24-Port RJ Patch Panel RJ-48C Cinch Plug Socket Pin # Pin # (CPE) Release 10.0.0 255-700-584 Appendix A Pin Configurations Connector Pin Assignments Table A-1. 21-Port High-Density E1 IMA Module Module Connector, Cable, and PSAX 24-Port RJ Patch Panel Pin Assignments (Continued) Lucent Cable (COMCODE 300550639) Module Connectors1 Port2 9/21 10/22 11/23 12/24 Signal Name Socket Pin #3 Mini Champ Plug P1 RJ-48H Socket P2 PSAX 24-Port RJ Patch Panel RJ-48C Cinch Plug Socket Pin # (CPE) Pin # RX-T 18 18 47 47 1 (T1) RX-R 43 43 22 22 2 (R1) TX-T 44 44 34 34 4 (T) TX-R 19 19 9 9 5 (R) RX-T 20 20 48 48 1 (T1) RX-R 45 45 23 23 2 (R1) TX-T 46 46 35 35 4 (T) TX-R 21 21 10 10 5 (R) RX-T 22 22 49 49 1 (T1) RX-R 47 47 24 24 2 (R1) TX-T 48 48 36 36 4 (T) TX-R 23 23 11 11 5 (R) RX-T 24 24 50 50 1 (T1) RX-R 49 49 25 25 2 (R1) TX-T 50 50 37 37 4 (T) TX-R 25 25 12 12 5 (R) 1 For 21-port E1 modules, one module can be connected to the patch panel. 2 Indicates port numbers from the module connectors and through the patch panel. 3 Pins 13 and 38 are not used. On the patch panel, the two Cinch sockets are labeled PORT 1–12, and PORT 13–24 and match with the RJ-48C connectors labeled 1–24. The pin assignments are the same for each connector. To the PSAX 48-Port RJ Patch Panel Table A-2 lists the pin assignments between the 21-Port High-Density E1 IMA module connectors, the Lucent cable, and the PSAX 48-Port RJ Patch Panel connectors, four 50-pin Cinch plugs and the 48 RJ-48C sockets. Note: The transmit and receive—tip and ring—pairs of the patch panel RJ-48C sockets are reversed from the standard RJ-48C pin assignments described in the ANSI T1.403 standard (Pin 1 R1, Pin 2 T1, Pin 4 R, and Pin 5 T). PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Release 10.0.0 A-5 Appendix A Pin Configurations Connector Pin Assignments Table A-2. 21-Port High-Density E1 IMA Module Connector, Cable, and PSAX 48-Port RJ Patch Panel Pin Assignments Lucent Cable (COMCODE 300550639) Module Connectors Port1 1/13/25/37 2/14/26/38 3/15/27/39 4/16/28/40 5/17/29/41 6/18/30/42 7/19/31/43 8/20/32/44 Signal Name Socket Pin #2 Mini Champ Cinch Socket Plug P1 P2 RX-T 1 1 39 39 1 (T1) RX-R 26 26 14 14 2 (R1) TX-T 27 27 26 26 4 (T) TX-R 2 2 1 1 5 (R) RX-T 3 3 40 40 1 (T1) RX-R 28 28 15 15 2 (R1) TX-T 29 29 27 27 4 (T) TX-R 4 4 2 2 5 (R) RX-T 5 5 41 41 1 (T1) RX-R 30 30 16 16 2 (R1) TX-T 31 31 28 28 4 (T) TX-R 6 6 3 3 5 (R) RX-T 7 7 42 42 1 (T1) RX-R 32 32 17 17 2 (R1) TX-T 33 33 29 29 4 (T) TX-R 8 8 4 4 5 (R) RX-T 9 9 43 43 1 (T1) RX-R 34 34 18 18 2 (R1) TX-T 35 35 30 30 4 (T) TX-R 10 10 5 5 5 (R) RX-T 11 11 44 44 1 (T1) RX-R 36 36 19 19 2 (R1) TX-T 37 37 31 31 4 (T) TX-R 12 12 6 6 5 (R) RX-T 14 14 45 45 1 (T1) RX-R 39 39 20 20 2 (R1) TX-T 40 40 32 32 4 (T) TX-R 15 15 7 7 5 (R) RX-T 16 16 46 46 1 (T1) RX-R 41 41 21 21 2 (R1) TX-T 42 42 33 33 4 (T) TX-R 17 17 8 8 5 (R) PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 A-6 PSAX 48-Port RJ Patch Panel RJ-48C Cinch Plug Socket Pin # Pin # (CPE) Release 10.0.0 255-700-584 Appendix A Pin Configurations Connector Pin Assignments Table A-2. 21-Port High-Density E1 IMA Module Connector, Cable, and PSAX 48-Port RJ Patch Panel Pin Assignments (Continued) Lucent Cable (COMCODE 300550639) Module Connectors Port1 9/21/33/45 10/22/34/46 11/23/35/47 12/24/36/48 Signal Name Socket Pin #2 Mini Champ Cinch Socket Plug P1 P2 PSAX 48-Port RJ Patch Panel RJ-48C Cinch Plug Socket Pin # (CPE) Pin # RX-T 18 18 47 47 1 (T1) RX-R 43 43 22 22 2 (R1) TX-T 44 44 34 34 4 (T) TX-R 19 19 9 9 5 (R) RX-T 20 20 48 48 1 (T1) RX-R 45 45 23 23 2 (R1) TX-T 46 46 35 35 4 (T) TX-R 21 21 10 10 5 (R) RX-T 22 22 49 49 1 (T1) RX-R 47 47 24 24 2 (R1) TX-T 48 48 36 36 4 (T) TX-R 23 23 11 11 5 (R) RX-T 24 24 50 50 1 (T1) RX-R 49 49 25 25 2 (R1) TX-T 50 50 37 37 4 (T) TX-R 25 25 12 12 5 (R) 1 Indicates port numbers from the module connectors and through the patch panel. 2 Pins 13 and 38 are not used. On the patch panel, the four Cinch sockets are labeled PORT 1–12, PORT 13–24, PORT 25–36, and PORT 37–48 and match with the RJ-48C connectors labeled 1–48. The pin assignments are the same for each connector. PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Release 10.0.0 A-7 Appendix A Pin Configurations Connector Pin Assignments PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 A-8 Release 10.0.0 255-700-584 B Reference Tables Overview of This Appendix This appendix contains reference information that is helpful while configuring your PSAX system. The following types of information are provided: • “Avoiding Common Errors When Configuring Interfaces” • “Optimizing SVC Call Performance” • “Connection Type by Interface Type Table” • “Interface Type by I/O Module Type Table” • “Module Alarm Status Table” • “ATM Service Categories in the PSAX System” • “ATM TS, UPC, and VI Configuration Capabilities” Avoiding Common Errors When Configuring Interfaces An error may occur when you apply an interface to a channel. If an error condition occurs, the PSAX system sends an SNMP trap that is usually displayed in the console Trap Log Display window (accessible from the Console Interface Main Menu window). The list below includes the most common interface errors that cause the PSAX system to display a message. (See the PacketStar® PSAX Simple Network Management Protocol (SNMP) Trap Reference Guide for more information about the SNMP traps related to interface errors). • Entering field values that are outside of the configurable range of values • Attempting to configure an interface for a port or channel that has already been configured • Attempting to configure an interface that is already in service (must be out of service to be configured or change field values) • Entering field values that are not recognized by the PSAX system software PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Release 10.0.0 B-1 Appendix B Reference Tables Optimizing SVC Call Performance Optimizing SVC Call Performance The information in this section provides guidance on optimizing call performance when configuring SVCs on the PNNI interface. The servicespecific connection-oriented protocol (SSCOP) parameter is set on these interface configuration windows: ATM IISP network or IISP user, ATM UNI 3.0 or UNI 3.1, or ATM PNNI 1.0. Note: These settings are suggested for connecting to a PSAX system from a remote site only. The PSAX system configures these settings internally in its own ATM switch. When unacknowledged protocol data units (PDUs), the MaxPD field on the remote end peer (such as the NavisCore™ CBX 500™) shows the maximum number of SSCOP packets transmitted since the last PSAX polling of the peer. To optimize call performance, the SSCOP Rx Window Size field of the local ATM interface should be less than the maximum value displayed in the MaxPD credit window at the remote end of the ATM interface. Otherwise, the rate at which switched calls can be set and released may be degraded. On the ATM IISP Interface Configuration window, the maximum credit window (the SSCOP Rx Window Size field) is configurable with a value up to 32 for all ATM interfaces on the PSAX system. The interfaces of the ATM switches that are connected to the PSAX system should be configured with the same values. This method results in 100 percent call completion at a call setup rate of 60 calls per second using even distribution. If these values are not configured in this way, calls will be set up at a rate of less than 60 calls per second. Note: Various SSCOP parameter settings determine the maximum credit window. As a result, you may not be able to directly use these settings. For more information on the SSCOP parameter, see the Application Note entitled Connecting a CBX or GX Switch to a PacketStar® PSAX Multiservice Media Gateway via an ATM Port. Connection Type by Interface Type Table The PacketStar® PSAX Multiservice Media Gateway provide a number of connection types and interface types to the network as described in Table B-1. Configuring interfaces and connections are described in the PacketStar® PSAX Connections Provisioning Guide that can be found on the PacketStar® PSAX Multiservice Media Gateways Product Information Library CD-ROM. PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 B-2 Release 10.0.0 255-700-584 Appendix B Reference Tables Connection Type by Interface Type Table AAL2 PVC Trunk X X X X X X AAL2 Channel PVC VCC Connection X X X X X X Terminal Emulation HDLC Pass-through PRI ISDN (Network/User) GR-303 Frame Relay (UNI, NNI) CAS TrunkLine Circuit Emulation Bridge ATM PNNI 1.0 ATM PNNI over VPC ATM UNI 3.0/3.1/4.0 ATM Virtual Interface Connection Type ATM IMA Interface Type ATM IISP (Network/User) Table B-1. Connection Type by Interface Type ATM-to-ATM virtual channel connection (VCC) X X X X X X PVC ATM-to-ATM virtual path connection (VPC) PVC X X X X Bridge-to-ATM VCC PVC X X X X X X X Bridge-to-bridge PVC X Circuit emulation-to ATM VCC PVC X X X X X X X Circuit emulation-to circuit emulation PVC X CPU Ethernet Bridge PVC X X X X X X Frame relay-to-ATM VCC PVC X X X X X X X Frame relay-to-frame relay PVC GR-303-to-AAL2 VCC PVC 1 X X X X X X X In-band management ATM PVC X X X X X X Variable bit rate (VBR)-to-ATM VCC PVC X X X X X X X2 VBR-to-VBR PVC In-Band Management SVC X X X X X X ATM-to-ATM VCC SPVC X X X X X ATM-to-ATM VPC SPVC X X X Circuit emulation-to-ATM VCC SPVC X X X X X X X CE-to-ATM Std AAL2 VCC SPVC X X X X X X Enhanced Router Module to ATM VCC SPVC X Frame relay-ATM VCC SPVC X X X X X VBR-to-ATM VCC SPVC X X X X X VBR-to-ATM Std AAL2 VCC SPVC X X X X X X X X X X X X X X X X X X 1 AAL2 PVCs must be configured before GR-303 connections can be configured. 2 A GR-303 Interface Group (IG) must be configured before GR-303 connections can be configured. PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 X Release 10.0.0 B-3 Appendix B Reference Tables Interface Type by I/O Module Type Table Interface Type by I/O Module Type Table Table B-2 shows the available interface types for each PacketStar PSAX I/O module used in the PacketStar® PSAX Multiservice Media Gateway. This table does not include other PSAX modules that are not I/O modules, which include: the Alarm module, the DSP2x modules, the Enhanced Router module, the Route Server module, and the Tones and Announcements Server module . GR-303 HDLC Pass-through PRI ISDN (Network/User) X X X X X X X X X X X V5.2 Frame Relay (UNI, NNI) X Terminal Emulation Circuit Emulation X Routing CAS Trunkline X Bridge X ATM UNI 3.0/3.1 X ATM UNI 4.0 ATM PNNI over VPC ATM PNNI 1.0 X ATM Virtual Interface Module ATM IMA Interface ATM IISP (Network/User) Table B-2. Interface Type by I/O Module Type DS1/T1 Interface Modules 6-Port DS1 IMA X 6-Port Enhanced DS1/T1 Multiservice X X 12-Port Medium-Density DS1 Multiservice X X 12-Port Medium-Density DS1 IMA X X X X X X X 12-Port Medium-Density DS1/E1/DS0A CES X1 X2 24-Port High-Density DS1 Multiservice X X X X 8-Port HDSL-2 X X X X X X X3 X X X4 X X X DS3, E3, and STS-1e Interface Modules 1-Port Channelized DS3 Multiservice X 1-Port DS3 IMA X X X X X X X X X X 1-Port Unchannelized DS3 Frame Relay X X X 1-Port Channelized STS-1e, T1 Format X X X X 2-Port DS3 ATM X X X X 2-Port E3 ATM X X X X PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 B-4 X X X X X X X Release 10.0.0 255-700-584 Appendix B Reference Tables Interface Type by I/O Module Type Table X X 3-Port Channelized DS3/STS-1e Multiservice Protection X V5.2 X Terminal Emulation X GR-303 3-Port Channelized DS3/STS-1e CES Protection Routing PRI ISDN (Network/User) HDLC Pass-through Frame Relay (UNI, NNI) Circuit Emulation X Bridge X ATM UNI 3.0/3.1 X ATM UNI 4.0 X Module ATM PNNI 1.0 3-Port Channelized DS3/STS-1e CES Interface ATM IMA CAS Trunkline ATM Virtual Interface ATM PNNI over VPC ATM IISP (Network/User) Table B-2. Interface Type by I/O Module Type (Continued) X 3-Port DS3/E3 ATM X X X X X 3-Port DS3/E3 ATM Protection X X X X X 3-Port Unstructured DS3/E3 CES X 3-Port Unstructured DS3/E3 CES Protection X E1 Interface Modules 6-Port E1 IMA X 6-Port Enhanced E1 Multiservice X X X X X X X X X X X X X 21-Port High-Density E1 Multiservice X X X X X X X X X 23N34 21-Port HighDensity E1 IMA X X X X X X Ethernet Interface Modules Ethernet X X 4-Port Ethernet X X Fiber-Optic Interface Modules 1-Port Channelized OC-3/STM-1 CES Multimode X X 1-Port Channelized OC-3/STM-1 CES Singlemode X X PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 X Release 10.0.0 B-5 Appendix B Reference Tables Interface Type by I/O Module Type Table 1-Port Channelized OC-3/STM-1 Unstructured CES/ATM Single-Mode X5 X5 X5 X5 X6 1-Port Channelized OC3/STM-1 Unstructured CES/ATM Multimode X5 X5 X5 X5 X6 2-Port OC-3c/STM-1 ATM Multimode X X X X 2-Port OC-3c/STM-1 ATM Single-Mode X X X X 4-Port OC-3c/STM-1 Multimode X X X X 4-Port OC-3c/STM-1 Single-Mode X X X X 1-Port OC-3c 1+1 APS Multimode X X X X X 1-Port OC-3c 1+1 APS Single-Mode X X X X X 1-Port STM-1 1+1 MSP Multimode X X X X X 1-Port STM-1 1+1 MSP Single-Mode X X X X X 1-Port OC-12c/STM-4c Multimode X X X X X 1-Port OC-12c/STM-4c Single-Mode X X X X X 2-Port OC-3c/STM-1 Enhanced ATM Multimode X X X X 2-Port OC-3c/STM-1 Enhanced ATM SingleMode X X X X V5.2 Terminal Emulation Routing PRI ISDN (Network/User) HDLC Pass-through GR-303 Frame Relay (UNI, NNI) Circuit Emulation CAS Trunkline Bridge ATM UNI 3.0/3.1 ATM UNI 4.0 ATM PNNI over VPC ATM PNNI 1.0 ATM Virtual Interface Module ATM IMA Interface ATM IISP (Network/User) Table B-2. Interface Type by I/O Module Type (Continued) Serial Interface Modules Quadserial X X X X PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 B-6 X X X X Release 10.0.0 255-700-584 Appendix B Reference Tables Module Alarm Status Table X V5.2 Terminal Emulation Routing PRI ISDN (Network/User) X HDLC Pass-through Frame Relay (UNI, NNI) X GR-303 Circuit Emulation CAS Trunkline X Bridge X ATM Virtual Interface ATM UNI 3.0/3.1 ATM PNNI over VPC 6-Port Multiserial ATM UNI 4.0 Module ATM PNNI 1.0 Interface ATM IMA ATM IISP (Network/User) Table B-2. Interface Type by I/O Module Type (Continued) X Voice 2-Wire Interface Modules 4-Port Voice 2-Wire Office X7 8-Port Voice 2-Wire Station X7 1 The module supports CAS Trunkline in DS1 and E1 modes only. 2 The module supports Circuit Emulation in DS1, E1, and DS0A modes. 3 The module supports GR-303 in DS1 mode only. 4 The module supports PRI ISDN in DS1 and E1 modes only. 5 The module supports ATM services in the STM-ATM mode only. 6 The module supports CE in the OC3-UCE mode only. 7 European modules do not support this interface with the 8-Port Voice 2-Wire Station module or the 4-Port Voice 2-Wire Office module. Module Alarm Status Table The Alarm Status field on the Equipment Configuration window is described in Table B-3. Table B-3. Module Alarm Status Descriptions on the Equipment Configuration Window Alarm Status Module Type Affected Description NoAlarm I/O and Server Indicates that no alarms have been detected for the module in this slot. WrongCardType I/O and Server Indicates that one type of module was configured in this slot in the chassis, but a now different module occupies this slot. LineFailed All Indicates that the module in this slot is no longer receiving or transmitting signals because the line failed. PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Release 10.0.0 B-7 Appendix B Reference Tables Module Alarm Status Table Table B-3. Module Alarm Status Descriptions on the Equipment Configuration Window (Continued) Alarm Status Module Type Affected Description Hexadecimal format, Example: 12345678ABC I/O and Server Indicates that one or more ports on the module in this slot currently have a loss of signal. The numbers indicate which ports have a loss of signal. For modules that have more than eight ports not receiving signals, the value in this field is in hexadecimal format. CardRemoved All Indicates that one of the following events occurred: • The module in this slot was configured and then removed from the slot. • Connections on the OC-3, OC-12, STM-1, or STM-4 APS/MSP primary module in this slot were transferred to the standby module. After the transfer occurs, the former primary module then displays CardRemoved in the Alarm Status field; the former standby module then displays Primary in the Status field. ReferenceClockFailed Stratum 3–4 Indicates that the timing reference clock on the Stratum module in this slot failed. CompositeClockFailed Stratum 3–4 Indicates that the timing composite clock on the Stratum module in this slot failed. Overload Power Supply Indicates that the Power Supply module is operating under an overload condition. PowerFailed Power Supply Indicates that the power has failed. Minus48vFailed Power Supply Indicates that the -48 V dc Power Supply module output failed. UnknownAlarm I/O and Server Indicates that the reason for failure is not known. CompleteClockFailed Stratum 3–4 Indicates that the backplane detected a clock error. PowerFailed Indicates that no power is coming into the PSAX chassis. Power Supply PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 B-8 Release 10.0.0 255-700-584 Appendix B Reference Tables ATM Service Categories in the PSAX System ATM Service Categories in the PSAX System ATM Service Category Descriptions The PSAX system support of defined ATM quality of service (QoS) categories is described in Table B-4. Table B-4. PSAX System-Supported Quality of Service Categories ATM Service Category Description Constant Bit Rate (CBR) This service offers consistent delay predictability. CBR is used for applications such as circuit emulation, voice, and video. Real Time Variable Bit Rate (VBR-rt) This service offers low delay variance, but requires access to a variable amount of network bandwidth. VBR-rt is used for applications such as packet video and voice. Non-Real Time Variable This service allows delay variance between the delivery of cells. VBR-nrt Bit Rate (VBR-nrt) is used for data applications that have potentially bursty traffic characteristics. Guaranteed Frame Rate This service allows delay variance and offers a minimum cell rate guaran(GFR) tee. When used with frame-based data encapsulated in AAL5 PDUs, it provides frame-based cell discard. GFR is used for frame relay or ethernet over ATM. Unspecified Bit Rate (UBR) This service allows for best-effort transport by the network. Cells are transported by the network whenever bandwidth is available and the user presents traffic. Priority of ATM Service Categories in the PSAX System The attributes of the categories of service supported by the PSAX system software are identified in Table B-5. The service examples in this table are intended simply as illustrations; you should choose your service category based on your network applications supported by the PSAX system. The flexibility of the PSAX system allows you to tailor the system based on the required service applications by selecting the appropriate connection configuration selection field value. PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Release 10.0.0 B-9 Appendix B Reference Tables ATM TS, UPC, and VI Configuration Capabilities Table B-5. Mapping ATM Service Categories to PSAX System Priority Levels ATM Forum Traffic Management Connection AQueMan Priority 4.1 Priority (Current ImplementaConfiguration (Legacy Impletion) Field Value mentation) ATM Service Category Constant Bit Rate (CBR) CBR1 Highest CBR2 Lower than CBR1 Preferred customers CBR3 Lower than CBR2 Standard CBR4 Lower than CBR3 Cellular VBR-express Lower than CBR4 VBR-rt1 Lower than VBR-express Real-time video VBR-rt2 Lower than VBR-rt1 MPEG 1-2/JPEG VBR-nrt1 Lower than VBR-rt2 VBR-nrt2 Lower than VBR-nrt1 Guaranteed Frame Rate (GFR) GFR2 Lowest (shares queue with UBR) Lower than VBR-nrt Frame relay, Ethernet, TCP Unspecified Bit Rate (UBR) UBR Lowest Lowest UDP Real Time Variable Bit Rate (VBR-rt) Non-Real Time Variable Bit Rate (VBR-nrt) Highest Service Examples 911 calls Lower than CBR Network management Lower than VBR-rt Data Data ATM TS, UPC, and VI Configuration Capabilities Configuration compatibility among the ATM Traffic Shaping, UPC Support, and VI Support features is shown in Table B-6. In the table, Yes indicates that the two features coinciding in the matrix can be configured in the same interface, and No indicates that they cannot. See Figure B-1 for an illustration of this concept. Table B-6. ATM Traffic Shaping, UPC Support, and VI Support Configuration Compatibility Fields on ATM UNI, PNNI, and IISP Configuration Windows ATM Traffic Shaping per VC VI Support ATM Traffic Shaping per VC VI Support UPC Support No No Yes 1 Yes PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 B-10 UPC Support Yes1 Yes Release 10.0.0 255-700-584 Appendix B Reference Tables ATM TS, UPC, and VI Configuration Capabilities 1 UPC support and Traffic Shaping per VC are supported on the same end-to-end connection only when VI is configured on the egress path, and UPC on the ingress path. I/O Module 1 Rx Ingress Path UPC Tx VI or TS Egress Path Chassis Backplane I/O Module 2 Rx Ingress Path UPC Tx VI or TS Egress Path Figure B-1. Combining the UPC Feature and Either the TS or VI Feature on a Connection ATM Traffic Shaping Capability by Module The ATM Traffic Shaping capability is supported on the PSAX modules listed in Table B-7. The table includes information on the maximum number of VCs using traffic shaping, minimum PCR for traffic shaping, queue size, priority, and precision of traffic shaping for one connection. Configuration compatibility among the ATM Traffic Shaping, UPC Support, and VI Support features is shown in The PSAX modules supporting ATM Traffic Shaping, UPC, or VI are listed in Table B-7. The table includes information on the maximum number of VCs using traffic shaping, minimum PCR for traffic shaping, queue size, priority, and precision of traffic shaping for one connection. PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Release 10.0.0 B-11 Appendix B Reference Tables ATM TS, UPC, and VI Configuration Capabilities Table B-7. ATM Traffic Management Capabilities by Module Feature Support Modules ATM Traffic Shaping (TS) Max. Min. Precision for One Queue No. of 1 Size PCR Connection2 EPD GFR UPC VI TS Priority VCs DS1/T1 Interface Modules 12-Port Medium-Density DS1 IMA x x 32,000 150 cps 2× MBS After VBR-rt2 ~50% of line rate 12-Port Medium-Density DS1 Multiservice x x 32,000 150 cps 2× MBS After VBR-rt2 ~50% of line rate 24-Port High-Density DS1 Multiservice x x 32,000 150 cps 2× MBS After VBR-rt2 ~50% of line rate E1 Interface Modules 23N34 E1 IMA 21-Port High-Density 21-Port High-Density E1 Multiservice x x 32,000 150 cps 2× MBS After VBR-rt2 ~50% of line rate x x 32,000 150 cps 2× MBS After VBR-rt2 ~50% of line rate DS3, E3, and STS-1e Interface Modules 1-Port Channelized STS-1e, T1 Format x x 32,000 150 cps 2× MBS After VBR-rt2 ~50% of line rate 1-Port DS3 IMA x3 x 32,000 150 cps 2× MBS After VBR-rt2 ~50% of line rate 1-Port Channelized DS3 Multiservice x3 x 32,000 150 cps 2× MBS After VBR-rt2 ~50% of line rate 3-Port DS3/E3 ATM x x 32,000 7 cps 2× MBS After CBR ~1% of line rate x Fiber-Optic Interface Modules 1-Port OC-12c/STM-4c Multimode x x x 32,000 87 cps 2× MBS After CBR ~1% of line rate 1-Port OC-12c/STM-4c Single-Mode x x x 32,000 87 cps 2× MBS After CBR ~1% of line rate 1-Port Channelized OC3/STM-1 Unstructured CES/ATM Multimode x x 32,000 9 cps 2× MBS After CBR ~50% of line rate 1-Port Channelized OC-3/STM-1 Unstructured CES/ATM Single-Mode x x 32,000 9 cps 2× MBS After CBR ~50% of line rate 2-Port OC-3c/STM-1 ATM Multimode x x x 32,000 24 cps 2× MBS After CBR ~1% of line rate 2-Port OC-3c/STM-1 ATM Single-Mode x x x 32,000 24 cps 2× MBS After CBR ~1% of line rate 2-Port OC-3c/STM-1 Enhanced ATM Multimode x x 32,000 24 cps 2× MBS After CBR ~1% of line rate PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 B-12 Release 10.0.0 255-700-584 Appendix B Reference Tables ATM TS, UPC, and VI Configuration Capabilities Table B-7. ATM Traffic Management Capabilities by Module (Continued) Feature Support Modules EPD GFR UPC VI ATM Traffic Shaping (TS) TS Max. No. of VCs Min. PCR1 Queue Size Priority x 32,000 24 cps 2× MBS After CBR ~1% of line rate Precision for One Connection2 2-Port OC-3c/STM-1 Enhanced ATM Single-Mode x 4-Port OC-3c/STM-1 Multimode x x x 32,000 24 cps 2× MBS After CBR ~1% of line rate 4-Port OC-3c/STM-1 Single-Mode x x x 32,000 24 cps 2× MBS After CBR ~1% of line rate N/A N/A N/A N/A Serial Interface Modules Quadserial N/A x3 1 If you specify a rate below the minimum supported PCR, the module defaults to traffic shaping at the minimum supported PCR. 2 A connection configured for a PCR less than the specified rate has an output rate within 1% of the configured PCR. 3 UPC is available only when using channelization to DS0s. ATM Traffic Shaping Sample CPS Calculation Table Use the information in Table B-8 as a guide for calculations to determine ATM traffic shaping for cps on the Sample calculation: If the ATM traffic-shaped connection is configured with the PCR (Minimum/Actual Target CPS column) value 906 and the maximum target CPS (Maximum Target CPS column) value 909, the ATM Traffic Shaping feature is actually shaping the traffic to the (Actual CPS column) value 906 cps. The divergence is smallest at low PCR. Table B-8. ATM Traffic Shaping CPS Calculation Table Actual Rate (in bps) Minimum/Actual Maximum Target Target CPS CPS 64,000 151 152 151 128,000 302 303 302 192,000 453 454 453 256,000 604 606 604 320,000 755 757 755 383,999 906 909 906 448,383 1,058 1,062 1,058 512,876 1,210 1,215 1,210 575,999 1,358 1,365 1,358 639,999 1,509 1,517 1,509 713,142 1,682 1,691 1,682 PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Actual CPS Release 10.0.0 B-13 Appendix B Reference Tables ATM TS, UPC, and VI Configuration Capabilities Table B-8. ATM Traffic Shaping CPS Calculation Table (Continued) Actual Rate (in bps) Minimum/Actual Maximum Target Target CPS CPS 767,999 1,811 1,822 1,811 831,999 1,962 1,974 1,962 896,765 2,115 2,129 2,115 959,999 2,264 2,280 2,264 1,025,752 2,419 2,437 2,419 1,085,216 2,559 2,579 2,559 1,151,998 2,717 2,739 2,717 1,217,559 2,872 2,896 2,872 1,279,998 3,019 3,046 3,019 1,349,187 3,182 3,212 3,182 1,412,828 3,332 3,365 3,332 1,482,770 3,497 3,533 3,497 1,543,915 3,641 3,680 3,641 1,610,320 3,798 3,840 3,798 1,663,997 3,925 3,970 3,925 1,741,393 4,107 4,156 4,107 1,782,854 4,205 4,257 4,205 1,804,335 4,256 4,308 4,256 1,826,339 4,307 4,362 4,307 1,848,886 4,361 4,416 4,361 1,871,997 4,415 4,472 4,415 1,895,693 4,471 4,529 4,471 1,919,997 4,528 4,588 4,528 1,944,932 4,587 4,648 4,587 1,970,523 4,647 4,710 4,647 1,996,797 4,709 4,774 4,709 2,023,781 4,773 4,839 4,773 2,051,504 4,838 4,907 4,838 2,079,997 4,906 4,976 4,906 2,109,293 4,975 5,047 4,975 2,139,425 5,046 5,120 5,046 2,170,431 5,119 5,195 5,119 2,202,350 5,194 5,273 5,194 2,235,220 5,272 5,353 5,272 2,269,087 5,352 5,435 5,352 2,303,996 5,434 5,520 5,434 PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 B-14 Actual CPS Release 10.0.0 255-700-584 Appendix B Reference Tables ATM TS, UPC, and VI Configuration Capabilities Table B-8. ATM Traffic Shaping CPS Calculation Table (Continued) Actual Rate (in bps) Minimum/Actual Maximum Target Target CPS CPS 2,339,996 5,519 5,607 5,519 2,377,139 5,606 5,698 5,606 2,415,480 5,697 5,791 5,697 2,455,078 5,790 5,888 5,790 2,495,996 5,887 5,988 5,887 2,538,301 5,987 6,091 5,987 2,582,065 6,090 6,198 6,090 2,627,364 6,197 6,308 6,197 2,674,282 6,307 6,423 6,307 2,722,905 6,422 6,542 6,422 2,773,329 6,541 6,665 6,541 2,825,656 6,664 6,793 6,664 2,879,996 6,792 6,927 6,792 2,936,466 6,926 7,065 6,926 2,995,195 7,064 7,209 7,064 3,056,322 7,208 7,359 7,208 3,119,995 7,358 7,516 7,358 3,186,378 7,515 7,679 7,515 3,255,647 7,678 7,850 7,678 3,327,995 7,849 8,028 7,849 3,403,631 8,027 8,215 8,027 3,482,785 8,214 8,411 8,214 3,565,709 8,410 8,616 8,410 3,652,677 8,615 8,831 8,615 3,743,994 8,830 9,058 8,830 3,839,994 9,057 9,296 9,057 3,941,047 9,295 9,547 9,295 4,047,561 9,546 9,812 9,546 4,159,994 9,811 10,093 9,811 4,278,851 10,092 10,389 10,092 4,404,699 10,388 10,704 10,388 4,538,175 10,703 11,039 10,703 4,679,993 11,038 11,395 11,038 4,830,960 11,394 11,775 11,394 4,991,992 11,774 12,181 11,774 5,164,130 12,180 12,616 12,180 PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 255-700-584 Actual CPS Release 10.0.0 B-15 Appendix B Reference Tables ATM TS, UPC, and VI Configuration Capabilities Table B-8. ATM Traffic Shaping CPS Calculation Table (Continued) Actual Rate (in bps) Minimum/Actual Maximum Target Target CPS CPS 5,348,563 12,615 13,083 12,615 5,546,658 13,082 13,586 13,082 5,759,991 13,585 14,129 13,585 5,990,391 14,128 14,718 14,128 6,239,990 14,717 15,358 14,717 6,511,294 15,357 16,056 15,357 6,807,262 16,055 16,820 16,055 7,131,418 16,819 17,661 16,819 7,487,988 17,660 18,591 17,660 7,882,093 18,590 19,624 18,590 8,319,987 19,623 20,778 19,623 8,809,398 20,777 22,076 20,777 9,359,986 22,075 23,548 22,075 9,983,985 23,547 25,230 23,547 10,697,126 25,229 27,171 25,229 11,519,982 27,170 29,435 27,170 12,479,981 29,434 32,111 29,434 13,614,524 32,110 35,322 32,110 14,975,977 35,321 39,246 35,321 16,639,974 39,245 44,152 39,245 18,719,971 44,151 50,459 44,151 21,394,253 50,458 58,869 50,458 24,959,961 58,868 70,642 58,868 29,951,954 70,641 88,303 70,641 37,439,942 88,302 117,737 88,302 49,919,923 117,736 176,605 117,736 PacketStar® PSAX 21-Port High-Density E1 IMA Module User Guide, Issue 1 B-16 Actual CPS Release 10.0.0 255-700-584 Part Number: 547M0A10001D1 Copyright © 2004 Lucent Technologies All rights reserved. ">
/
Herunterladen
Nur eine freundliche Erinnerung. Sie können das Dokument direkt hier ansehen. Aber was am wichtigsten ist, unsere KI hat es bereits gelesen. Sie kann komplexe Dinge einfach erklären, Ihre Fragen in jeder Sprache beantworten und Ihnen helfen, auch in den längsten oder kompliziertesten Dokumenten schnell zu navigieren.
Werbung