- Computers & electronics
- Computer components
- System components
- Server/workstation motherboards
- User manual
advertisement
Intel
®
Intel
®
Workstation Board W2600CR
Technical Product Specification
Intel order number G34153-003
Revision 1.2
October, 2013
Enterprise Platforms and Services Division - Marketing
ii
Revision History
Revision History
Date
February, 2012
June, 2012
October, 2013
Revision
Number
1.0
1.1
1.2
Modifications
Initial release.
Updated thermal management and environmental summary.
Updated onboard power connectors information.
Added support for Intel
®
Xeon
®
processor E5-2600 v2 product family
Updated memory support tables
Disclaimers
INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE,
EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS
GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN INTEL'S TERMS AND CONDITIONS OF SALE FOR
SUCH PRODUCTS, INTEL ASSUMES NO LIABILITY WHATSOEVER AND INTEL DISCLAIMS ANY EXPRESS OR
IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF INTEL PRODUCTS INCLUDING LIABILITY OR
WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR
INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT.
A "Mission Critical Application" is any application in which failure of the Intel Product could result, directly or indirectly, in personal injury or death. SHOULD YOU PURCHASE OR USE INTEL'S PRODUCTS FOR ANY SUCH MISSION
CRITICAL APPLICATION, YOU SHALL INDEMNIFY AND HOLD INTEL AND ITS SUBSIDIARIES,
SUBCONTRACTORS AND AFFILIATES, AND THE DIRECTORS, OFFICERS, AND EMPLOYEES OF EACH,
HARMLESS AGAINST ALL CLAIMS COSTS, DAMAGES, AND EXPENSES AND REASONABLE ATTORNEYS'
FEES ARISING OUT OF, DIRECTLY OR INDIRECTLY, ANY CLAIM OF PRODUCT LIABILITY, PERSONAL
INJURY, OR DEATH ARISING IN ANY WAY OUT OF SUCH MISSION CRITICAL APPLICATION, WHETHER OR
NOT INTEL OR ITS SUBCONTRACTOR WAS NEGLIGENT IN THE DESIGN, MANUFACTURE, OR WARNING OF
THE INTEL PRODUCT OR ANY OF ITS PARTS.
Intel may make changes to specifications and product descriptions at any time, without notice. Designers must not rely on the absence or characteristics of any features or instructions marked "reserved" or "undefined". Intel reserves these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them. The information here is subject to change without notice. Do not finalize a design with this information.
The products described in this document may contain design defects or errors known as errata which may cause the product to deviate from published specifications. Current characterized errata are available on request.
Contact your local Intel sales office or your distributor to obtain the latest specifications and before placing your product order.
Copies of documents which have an order number and are referenced in this document, or other Intel literature, may be obtained by calling 1-800-548-4725, or go to: http://www.intel.com/design/literature .
Intel order number G34153-003 Revision 1.2
Table of Contents
Table of Contents
Main Board Connector and Component Layout ...................................................... 5
Integrated Memory Controller (IMC) and Memory Subsystem .............................. 26
C600-A Chipset Functional overview ........................................................... 34
Serial Attached SCSI (SAS)/SATA (SCU) Controller ............................................. 35
Compatibility Modules (DMA Controller, Timer/Counters, Interrupt Controller) ..... 36
Advanced Programmable Interrupt Controller (APIC) ........................................... 36
Virtualization Technology for Directed I/O (Intel® VT-d) ........................................ 38
Revision 1.2 Intel order number G34153-003 iii
Table of Contents
On-board SAS/SATA Support and Options ........................................................... 38
I/O Module Support (not avaiable for Intel
Server Board S2600IP4L and Intel
Workstation Board W2600CR Only) ............................. 43
Workstation Board W2600CR Only) ................................ 44
Workstation Board W2600CR Only) ........................... 45
Server Management Functional Specifications ..................................................... 51
Core Sensor List for EPSD Platforms Based on Intel
BMC System Management Health Monitoring ....................................................... 55
iv Intel order number G34153-003 Revision 1.2
Table of Contents
Enabling Advanced Management Features ........................................................... 77
Intelligent Power Node Manager (NM) ......................................................... 80
RAID C600 Upgrade Key Connector ............................................................ 92
Revision 1.2 Intel order number G34153-003 v
Table of Contents
Serial Port A Connector (DB9, for Intel
Server Board S2600IP only) .................. 95
Server Board S2600IP only) ..................................... 96
Internal Video header (For Intel
Workstation Board W2600CR only) .................. 97
BIOS Default and Password Reset Usage Procedure ........................................... 99
System ID LED, System Status LED and POST Code Diagnostic LEDs ............ 104
vi Intel order number G34153-003 Revision 1.2
Table of Contents
Residual Voltage Immunity in Standby mode ...................................................... 114
Server Board S2600IP .......................................................... 140
Server Chassis ................................................................. 145
Server Board W2600CR ....................................................... 147
Revision 1.2 Intel order number G34153-003 vii
Table of Contents
Server Chassis ................................................................. 148
viii Intel order number G34153-003 Revision 1.2
List of Figures
List of Figures
Server Board S2600IP Major Components .......................................................... 6
Workstation Board W2600CR Rear I/O Layout .................................................... 9
Server Board S2600IP Functional Block Diagram ........................................... 19
Workstation Board W2600CR Functional Block Diagram ................................ 20
Figure 18. Integrated Memory Controller Functional Block Diagram .......................................... 26
– TPM Configuration Screen ................................................................. 86
Figure 31. Location of System Status, System ID and POST Code Diagnostic LEDs .............. 105
Revision 1.2 Intel order number G34153-003 ix
x
List of Tables
List of Tables
Server Board S2600IP/Workstation Board W2600CR PCI Bus Segment
Integrated RAID Modules ................................................................... 43
– Security Configuration Screen Fields ................................................ 86
Intel order number G34153-003 Revision 1.2
List of Tables
RAID C600 Upgrade Key Connector Pin-out .................................................... 92
Server Board S2600IP MTBF Estimate ........................................................... 109
Workstation Board W2600CR MTBF Estimate ................................................ 109
Processor Dual Processor TDP profile ................................................. 112
Server Board S2600IP - BMC Channel Assignments ..................................... 140
Server Board S2600IP - Chassis-specific Sensors ......................................... 141
Server Board S2600IP - Fan Domain Definition .............................................. 142
Server Chassis P4208/P4216/P4224/P4308 (UPL) Power support ................ 145
Server Chassis R2208/R2216/R2224/R2308/R2312 (BHP) Power support ... 145
Workstation Board W2600CR - BMC Channel Assignments .......................... 146
Revision 1.2 Intel order number G34153-003 xi
List of Tables
Workstation Board W2600CR - Chassis-specific sensors ............................... 147
Workstation Board W2600CR - Fan domain definition .................................... 147
Server Chassis P4304 (UPL) Power support .................................................. 148
xii Intel order number G34153-003 Revision 1.2
<This page is intentionally left blank.>
List of Tables
Revision 1.2 Intel order number G34153-003 xiii
Introduction
1. Introduction
This Technical Product Specification (TPS) provides board-specific information detailing the features, functionality, and high-level architecture of the Intel
®
Server Board S2600IP and Intel
®
Workstation Board
W2600CR.
In addition, you can obtain design-level information for a given subsystem by ordering the External
Product Specifications (EPS) for the specific subsystem. EPS documents are not publicly available and you must order them through your local Intel representative.
1.1 Chapter Outline
This document is divided into the following chapters:
Chapter 1
– Introduction
Chapter 2
– Product Overview
Chapter 3
– Functional Architecture
Chapter 4
– Platform Management Overview
Chapter 5
– System Security
Chapter 6
– Connector/Header Locations and Pin-outs
Chapter 7
– Jumper Blocks
Chapter 8
– Intel ®
Light Guided Diagnostics
Chapter 9
– Design and Environmental Specifications
Appendix A: Integration and Usage Tips
Appendix B: BMC Sensor Tables
Appendix C: Platform Specific BMC Appendix
Appendix D: POST Code Diagnostic LED Decoder
Appendix E: POST Error Messages and Handling
Glossary
Reference Documents
1.2 Server Board Use Disclaimer
Intel
®
Server Boards contain a number of high-density VLSI (Very-large-scale integration) and power delivery components that require adequate airflow for cooling. Intel ensures through its own chassis development and testing that when Intel
®
server building blocks are used together, the fully integrated system meets the intended thermal requirements of these components. It is the responsibility of the system integrator who chooses not to use Intel developed server building blocks to consult vendor datasheets and operating parameters to determine the amount of airflow required for their specific application and environmental conditions. Intel Corporation cannot be held responsible if components fail or the server board does not operate correctly when used outside any of the published operating or nonoperating limits.
Revision 1.2 Intel order number G34153-003 1
Product Overview
2. Product Overview
The Intel
®
Server Board S2600IP and Intel
®
Workstation Board W2600CR are Enterprise I/O Rich platforms for Pedestal and Rack Server and workstation market.
Figure 1. Intel
®
Server Board S2600IP
Figure 2. Intel
®
Workstation Board W2600CR
2 Intel order number G34153-003 Revision 1.2
Product Overview
2.1 Product Feature Set
Board Name
Processors
Chipset
Table 1. Product Feature Set
Intel
®
Support for one or two Intel
2600 Processor(s) and Intel
®
®
Xeon
®
E5-
Xeon
®
E5-
2600 v2 Processor(s)
8 GT/s Intel
®
Quick Path Interconnect
(Intel
®
QPI)
Intel
®
Support for one or two Intel
®
Xeon
®
2600 Processor(s) and Intel
®
Xeon
®
E5-
E5-
2600 v2 Processor(s)
8 GT/s Intel
®
Quick Path Interconnect (Intel
®
QPI)
LGA 2011 Socket
Thermal Design Power up to 135 W
LGA 2011 Socket
Thermal Design Power up to 150 W
Intel
®
C600-A chipset with support for optional Intel
®
C600 RAID Upgrade Keys
Memory
Slots
16 DDR3 DIMMs with 800MT/s, 1067MT/s, 1333MT/s,1600MT/s, *1866MT/s
Eight memory channels (four channels for each processor socket)
Channels A, B, C, D, E, F, G and H
Support for Registered DDR3 Memory (RDIMM), Unbuffered DDR3 memory ((UDIMM) and
Load Reduced DDR3 memory (LRDIMM)
DDR3 standard I/O voltage of 1.5V and DDR3 Low Voltage of 1.35V
Slot 1: PCIe Gen3 x16, connector from first processor.
Slot 2: PCIe Gen3 x8, connector from first processor.
Slot 3: PCIe Gen3 x16, connector from first processor.
Slot 4: PCIe Gen3 x8, connector from second processor.
Slot 5: PCIe Gen3 x16, connector from second processor.
Slot 6: PCIe Gen3 x8, connector, from second processor
Slot 7: PCIe Gen3 x16,connector, from second processor
Slot 8: PCIe Gen2 x4 electrical with x8 physical connector, from second processor
IOM Connector: I/O Module (optional with Flex Cable*)
Notes: The IOM connector is not available for all boards and only supports PCIe Gen1 Speed
SM Conn: SAS Module (optional)
6Gbps or 12Gbps SAS ROC module Options
Ethernet
On-board storage controllers and options
Video
Intel
®
I350 Quad 1GbE fully integrated GbE
MAC and PHY Network Controller
Intel
®
I350 Dual 1GbE fully integrated GbE MAC and PHY Controller
One eUSB 2x5 pin connector to support 2mm low-profile eUSB solid state devices
Two 7-pin single port AHCI SATA connectors capable of supporting up to 6 GB/sec
Two SCU 4-port mini-SAS connectors capable of supporting up to 3 GB/sec SAS/SATA
Intel
®
Integrated RAID module support (Optional)
Intel
®
RAID C600 Upgrade Key support providing optional expanded SATA/SAS RAID capabilities
Integrated Matrox* G200 2D Video
Graphics controller
1 Rear VGA port
Integrated Matrox* G200 2D Video
Graphics controller
1 Internal VGA connector
Revision 1.2 Intel order number G34153-003 3
Product Overview
Board Name
Audio
I/O
Server
Management
Security
None
Intel
®
Intel
®
ALC889 HD Audio (7.1 + S/PDIF Out)
4 Rear USB2.0 1 Rear Serial A
4 Rear USB2.0 2 Rear USB3.0
2 Type A USB2.0 Connectors
1 Internal Serial B
2 Type A USB2.0 Connector
1 1394b Connector
1 Internal Serial B
Onboard Server Engines* LLC Pilot III* Controller
Support for Intel
®
Remote Management Module 4 solutions
Intel
®
Light-Guided Diagnostics on field replaceable units
Support for Intel
®
System Management Software
Support for Intel
®
Intelligent Power Node Manager (Need PMBus*-compliant power supply)
Intel
®
Trusted Platform Module (TPM) - AXXTPME5 (accessory option)
Power-Supply 750W/1200W/1600W Common Redundant Power-Supply with PMBus* Support
Supported Suspend to RAM
(S3)
Form Factor
Chassis
None
Custom 14.2'' W x 15.0'' D
Pedestal: P4000L chassis
2U Rack: R2000 chassis
Pedestal: P4000L WS chassis
*1866MT/s is only for
Intel
®
Xeon
®
processor E5-2600 v2 product family
4 Intel order number G34153-003 Revision 1.2
Product Overview
2.1.1 Main Board Connector and Component Layout
The following figure shows the layout of the server board. Each connector and major component is identified by a number or letter, and a description is given below the figure.
Callout
A
B
C
D
E
F
G
H
I
J
K
Description
Slot 1, PCI Express* Gen3
RMM4 lite module connector
Slot 2, PCI Express* Gen3
TPM
Slot 3, PCI Express* Gen3
Slot 4, PCI Express* Gen3
RMM4 Connector
Slot 5, PCI Express* Gen3
Battery
Slot 6, PCI Express* Gen3
Slot 7, PCI Express* Gen3
Revision 1.2 Intel order number G34153-003
Callout
AD
AE
AF
AG
AH
AI
AJ
AK
AL
AM
AN
Description
DIMM C1/C2/D1/D2
System Fan connector 1/2/3/4/5/6
Type A USB connector
Type A USB connector
ROC Module connector
LCP connector
Front Panel connector
Front Panel USB connector
Main Power 4-pin connector
MinISAS Port B(4-7)
MiniSAS Port A(0-3)
5
Product Overview
W
X
Y
Z
S
T
U
V
Callout
L
M
N
O
P
Q
R
Description
Slot 8, PCI Express* Gen2
DIMM E1/E2/F1/F2
Status LED
ID LED
Diagnostic LED
NIC 3/4 (S2600IP only)
USB 2/3, NIC 2
USB 0/1, NIC 1
VGA Port (S2600IP only)
Serial Port A (S2600IP only)
Processor 2 Power connector
Processor 2 Fan connector
DIMM H2/H1/G2/G1
PMBus* connector
Main Power connector
AA Processor 1 Power connector
AB DIMM B2/B1/A2/A1
AC Processor 1 Fan connector
AV
AW
AX
AY
AZ
BA
BB
BC
Callout
AO
AP
AQ
AR
AS
AT
AU
BD
BE
SATA Port 1
SATA Port 0
CPLD Update
Description
IPMB
HDD LED
ME FRC UPDT
CMOS CLR
BIOS RCVRY
PASSWD CLR
Storage Upgrade Key eUSB SSD
HSBP connector
Chassis intrusion
Serial B connector
BMC Force Update
I/O Module connector (not available for S2600IP4L)
System Fan connector 7
Figure 3. Intel
®
Server Board S2600IP Major Components
6 Intel order number G34153-003 Revision 1.2
Product Overview
G
H
I
J
K
L
M
Callout
A
B
C
D
E
F
N
O
P
Description
Slot 1, PCI Express* Gen3
RMM4 Lite module
Slot 2, PCI Express* Gen3
TPM
Slot 3, PCI Express* Gen3
Slot 4, PCI Express* Gen3
RMM4 Connector
Slot 5, PCI Express* Gen3
Battery
Slot 6, PCI Express* Gen3
Slot 7, PCI Express* Gen3
Slot 8, PCI Express* Gen2
DIMM E1/E2/F1/F2
Status LED
ID LED
Diagnostic LED
Revision 1.2 Intel order number G34153-003
AK
AL
AM
AN
AO
AP
AQ
Callout
AE
AF
AG
AH
AI
AJ
AR
AS
AT
Description
DIMM C1/C2/D1/D2
System Fan connector 1/2/3/4/5/6
Type A USB connector
Type A USB connector
ROC Module connector
LCP connector
Front Panel connector
Front Panel USB connector
Main Power 4-pin connector
1394b connector(W2600CR only)
MiniSAS Port B(4-7)
MiniSAS Port A(0-3)
SATA Port 1
SATA Port 0
CPLD Update
IPMB
7
Product Overview
Callout
Q
R
S
T
U
V
W
SPDIF connector
USB 2/3, NIC 2
USB 0/1, NIC 1
Description
USB3.0 0/1(W2600CR only)
HD Audio (W2600CR only)
Processor 2 Power connector
Front Audio connector
X
Y
Processor 2 Fan connector
DIMM H2/H1/G2/G1
Z PMBus* connector
AA Main Power connector
AB Processor 1 Power connector
AC DIMM B2/B1/A2/A1
AD Processor 1 Fan connector
Callout
AU
AV
AW
AX
AY
AZ
BA
BB
BC
BD
BE
BF
BG
BH
Description
HDD LED
ME FRC UPDT
CMOS CLR
BIOS RCVRY
PASSWD CLR
Storage Upgrade Key eUSB SSD
HSBP connector
Chassis intrusion
Serial B connector
BMC Force Update
I/O Module connector (not available for W2600CR2L)
Internal video connector
System Fan connector 7
Figure 3. Intel
®
Workstation Board W2600CR Major Components
2.1.2 Main Board Rear I/O Layout
The following drawing shows the layout of the rear I/O components for the server boards.
Callout
A
B
C
D
Description
Serial Port A
Video Port
NIC Port 1, USB Port 0 (bottom) and 1
(top)
NIC Port 2, USB Port 2 (bottom) and 3
(top)
Callout
E
F
G
H
Description
NIC Port 3(top) and 4(bottom)
Diagnostics LED’s
ID LED
Status LED
Figure 4. Intel
®
Server Board S2600IP Rear I/O Layout
8 Intel order number G34153-003 Revision 1.2
Callout
A
B
C
D
Description
7.1 Channel HD Audio Jack Connector
USB3.0 Port 0(bottom) and 1(top)
NIC Port 1, USB Port 0 (bottom) and 1
(top)
NIC Port 2, USB Port 2 (bottom) and 3
(top)
Callout
E
F
Description
Diagnostics LED’s
ID LED
G Status LED
Figure 5. Intel
®
Workstation Board W2600CR Rear I/O Layout
Product Overview
Revision 1.2 Intel order number G34153-003 9
Product Overview
2.1.3 Server Board Mechanical Drawings
10
Figure 6. Mounting Hole Locations (1 of 2)
Intel order number G34153-003 Revision 1.2
Product Overview
Figure 7. Mounting Hole Locations (2 of 2)
Revision 1.2 Intel order number G34153-003 11
Product Overview
12
Figure 8. Major Connector Pin-1 Locations (1 of 3)
Intel order number G34153-003 Revision 1.2
Product Overview
Figure 9. Major Connector Pin-1 Locations (2 of 3)
Revision 1.2 Intel order number G34153-003 13
Product Overview
14
Figure 10. Major Connector Pin-1 Locations (3 of 3)
Intel order number G34153-003 Revision 1.2
Product Overview
Revision 1.2 Intel order number G34153-003 15
Product Overview
Figure 11. Primary Side Keep-out Zone
16 Intel order number G34153-003 Revision 1.2
Product Overview
Figure 12. Primary Side Card-Side Keep-out Zone
Revision 1.2 Intel order number G34153-003 17
Product Overview
Figure 13. Second Side Keep-out Zone
18 Intel order number G34153-003 Revision 1.2
Functional Architecture
3. Functional Architecture
The architecture and design of the Intel
®
Server Board S2600IP and Intel is based on the Intel
®
Sandy Bridge-EP Processor series in an LGA 2011 Socket with Intel
®
®
Workstation Board W2600CR
C600-A chipset. The chipset is designed for systems based on the Intel
®
Xeon
®
Quick Path Interconnect (Intel
®
QPI) speed at 8GT/s.
This chapter provides a high-level description of the functionality associated with each chipset component and the architectural blocks that make up the server boards.
Revision 1.2
Figure 14. Intel
®
Server Board S2600IP Functional Block Diagram
Intel order number G34153-003 19
Functional Architecture
Figure 15. Intel
®
Workstation Board W2600CR Functional Block Diagram
3.1 Processor Support
The server board includes two Socket-R (LGA2011) processor sockets and can support one or two of the following processors - Intel
®
Xeon
®
processor E5-2600 and E5-2600 v2 product family with a Thermal
Design Power (TDP) of up to 150W.
Note: The 150w TDP processor is only supported on Intel
®
Workstation Board W2600CR and Intel
®
Server Board S2600IP only supports up to 135W TDP processors. Previous generation Intel
®
Xeon
® processors are not supported on the Intel server boards described in this document.
For a complete updated list of supported processors, please visit the support website.
3.1.1 Processor Socket Assembly
Each processor socket of the server board is pre-assembled with an Independent Latching Mechanism
(ILM) and Back Plate which allow for secure placement of the processor and processor heat to the server board. The illustration below identifies each sub-assembly component.
20 Intel order number G34153-003 Revision 1.2
Functional Architecture
Heat Sink
Server Board
Independent Latching
Mechanism (ILM)
Back Plate
Figure 16. Processor Socket Assembly
80mm
80mm
Figure 17. Processor Socket ILM
The square ILM has an 80x80mm heat sink mounting hole pattern and is used on the Intel
®
Server Board
S2600IP and Intel
®
Workstation Board W2600CR.
Note: Processor Thermal solutions for the Intel
®
Workstation Board W2600CR are NOT the same with
Intel
®
Server Board S2600IP when install 150W TDP Processors.
3.1.2 Processor Population Rules
Note: Although the server board does support dual-processor configurations consisting of different processors that meet the defined criteria below, Intel does not perform validation testing of this configuration.
For optimal system performance in dual-processor configurations, Intel recommends that identical processors be installed.
Revision 1.2 Intel order number G34153-003 21
Functional Architecture
When using a single processor configuration, the processor must be installed into the processor socket labeled
“CPU_1”.
When two processors are installed, the following population rules apply:
Both processors must be of the same processor family.
Both processors must have the same number of cores.
Both processors must have the same cache sizes for all levels of processor cache memory.
Processors with different core frequencies can be mixed in a system, given the prior rules are met. If this condition is detected, all processor core frequencies are set to the lowest common denominator (highest common speed) and an error is reported.
Processors which have different QPI link frequencies may operate together if they are otherwise compatible and if a common link frequency can be selected. The common link frequency would be the highest link frequency that all installed processors can achieve.
Processor stepping within a common processor family can be mixed as long as it is listed in the processor specification updates published by Intel Corporation.
3.1.3 Processor Initialization Error Summary
The following table describes mixed processor conditions and recommended actions for all Intel
® server boards and Intel server systems designed around the Intel
®
Xeon
® processor E5-2600 and E5-
2600 v2 product family and Intel
®
C600 chipset product family architecture. The errors fall into one of the following three categories:
Fatal: If the system can boot, it pauses at a blank screen with the text
“Unrecoverable
fatal error found. System will not boot until the error is resolved” and “Press <F2>
to enter setup”, regardless of whether the “Post Error Pause” setup option is enabled or disabled.
When the operator presses the <F2> key on the keyboard, the error message is displayed on the Error Manager screen, and an error is logged to the System Event Log
(SEL) with the POST Error Code.
The system cannot boot unless the error is resolved. The user needs to replace the faulty part and restart the system.
For Fatal Errors during processor initialization, the System Status LED will be set to a steady Amber color, indicating an unrecoverable system failure condition.
Major:
If the “Post Error Pause” setup option is enabled, the system goes directly to the
Error Manager to display the error, and logs the POST Error Code to SEL. Operator intervention is required to continue booting the system.
Otherwise, if “POST Error Pause” is disabled, the system continues to boot and no prompt is given for the error, although the Post Error Code is logged to the Error
Manager and in a SEL message.
22 Intel order number G34153-003 Revision 1.2
Functional Architecture
Minor: The message is displayed on the screen or on the Error Manager screen, and the POST Error Code is logged to the SEL. The system continues booting in a degraded state. The user may want to replace the erroneous unit. The POST Error Pause option setting in the BIOS setup does not have any effect on this error.
Table 2. Mixed Processor Configurations Error Summary.
Error
Processor family not Identical
Processor model not Identical
Processor cores/threads not identical Fatal
Processor cache not identical
Severity
Fatal
Fatal
Fatal
System Action
The BIOS detects the error condition and responds as follows:
Logs the POST Error Code into the System Event Log (SEL).
Alerts the BMC to set the System Status LED to steady Amber.
Displays “0194: Processor family mismatch detected” message in the Error Manager.
Takes Fatal Error action (see above) and will not boot until the fault condition is remedied.
The BIOS detects the error condition and responds as follows:
Logs the POST Error Code into the System Event Log (SEL).
Alerts the BMC to set the System Status LED to steady Amber.
Displays “0196: Processor model mismatch detected” message in the Error Manager.
Takes Fatal Error action (see above) and will not boot until the fault condition is remedied.
The BIOS detects the error condition and responds as follows:
Logs the POST Error Code into the SEL.
Alerts the BMC to set the System Status LED to steady Amber.
Displays “0191: Processor core/thread count mismatch
detected
” message in the Error Manager.
Takes Fatal Error action (see above) and will not boot until the fault condition is remedied.
The BIOS detects the error condition and responds as follows:
Logs the POST Error Code into the SEL.
Alerts the BMC to set the System Status LED to steady Amber.
Displays “0192: Processor cache size mismatch detected message in the Error Manager.
Takes Fatal Error action (see above) and will not boot until the fault condition is remedied.
Revision 1.2 Intel order number G34153-003 23
Functional Architecture
Processor Intel QuickPath
Interconnect link frequencies not identical
®
Error
Processor frequency (speed) not identical
Processor microcode update missing
Processor microcode update failed
Severity
Fatal
Fatal
Minor
Major
System Action
The BIOS detects the processor frequency difference, and responds as follows:
Adjusts all processor frequencies to the highest common frequency.
No error is generated – this is not an error condition.
Continues to boot the system successfully.
If the frequencies for all processors cannot be adjusted to be the
same, then this is an error, and the BIOS responds as follows:
Logs the POST Error Code into the SEL.
Alerts the BMC to set the System Status LED to steady Amber.
Does not disable the processor.
Displays “0197: Processor speeds unable to synchronize” message in the Error Manager.
Takes Fatal Error action (see above) and will not boot until the fault condition is remedied.
The BIOS detects the QPI link frequencies and responds as follows:
Adjusts all QPI interconnect link frequencies to highest common frequency.
No error is generated
– this is not an error condition.
Continues to boot the system successfully.
If the link frequencies for all QPI links cannot be adjusted to be the
same, then this is an error, and the BIOS responds as follows:
Logs the POST Error Code into the SEL.
Alerts the BMC to set the System Status LED to steady Amber.
Displays “0195: Processor Intel(R) QPI link frequencies
unable to synchronize
” message in the Error Manager.
Does not disable the processor.
Takes Fatal Error action (see above) and will not boot until the fault condition is remedied.
The BIOS detects the error condition and responds as follows:
Logs the POST Error Code into the SEL.
Displays “818x: Processor 0x microcode update not found” message in the Error Manager or on the screen.
The system continues to boot in a degraded state, regardless of the setting of POST Error Pause in the Setup.
The BIOS detects the error condition and responds as follows:
Logs the POST Error Code into the SEL.
Displays “816x: Processor 0x unable to apply microcode
update
” message in the Error Manager or on the screen.
Takes Major Error action. The system may continue to boot in a degraded state, depending on the setting of POST Error Pause in
Setup, or may halt with the POST Error Code in the Error Manager waiting for operator intervention.
24 Intel order number G34153-003 Revision 1.2
Functional Architecture
3.2 Processor Functions Overview
With the release of the Intel
®
Xeon
®
processor E5-2600 and E5-2600 v2 product family, several key system components, including the CPU, Integrated Memory Controller (IMC), and
Integrated IO Module (IIO), have been combined into a single processor package and feature per socket; two Intel
®
QuickPath Interconnect point-to-point links capable of up to 8.0 GT/s, up to
40 lanes of Gen 3 PCI Express* links capable of 8.0 GT/s, and 4 lanes of DMI2/PCI Express*
Gen 2 interface with a peak transfer rate of 5.0 GT/s. The processor supports up to 46 bits of physical address space and 48-bit of virtual address space.
The following sections will provide an overview of the key processor features and functions that help to define the performance and architecture of the server board. For more comprehensive processor specific information, refer to the Intel
®
Xeon
®
processor E5-2600 and E5-2600 v2 product family documents listed in the Reference Document list.
Processor Feature Details:
Up to 8 execution cores for Intel
®
Xeon
®
processor E5-2600 product family
Up to 12 execution cores for Intel
®
Xeon
®
processor E5-2600 v2 product family
Each core supports two threads (Intel
®
Hyper-Threading Technology), up to 16 threads per socket for E5-2600 and 24 threads per socket for E5-2600 v2
46-bit physical addressing and 48-bit virtual addressing
1 GB large page support for server applications
A 32-KB instruction and 32-KB data first-level cache (L1) for each core
A 256-KB shared instruction/data mid-level (L2) cache for each core
Up to 20 MB last level cache (LLC) for E5-2600: up to 2.5 MB per core instruction/data last level cache (LLC), shared among all cores
Up to 30 MB last level cache (LLC) for E5-2600 v2: up to 2.5 MB per core instruction/data last level cache (LLC), shared among all cores
Supported Technologies:
Intel
®
Virtualization Technology (Intel
®
VT)
Intel
®
Virtualization Technology for Directed I/O (Intel
®
VT-d)
Intel
®
Virtualization Technology
“Sandy Bridge” Processor Extensions
Intel
®
Trusted Execution Technology (Intel
®
TXT)
Intel
®
64 Architecture
Intel
®
Streaming SIMD Extensions 4.1 (Intel
®
SSE4.1)
Intel
®
Streaming SIMD Extensions 4.2 (Intel
®
SSE4.2)
Intel
®
Advanced Vector Extensions (Intel
®
AVX)
Intel
®
Hyper-Threading Technology
Execute Disable Bit
Intel
®
Turbo Boost Technology
Intel
®
Intelligent Power Technology
Enhanced Intel
®
SpeedStep Technology
Revision 1.2 Intel order number G34153-003 25
Functional Architecture
3.2.1 Intel
®
QuickPath Interconnect
The Intel
®
QuickPath Interconnect is a high speed, packetized, point-to-point interconnect used in the processor. The narrow high-speed links stitch together processors in distributed shared memory and integrated I/O platform architecture. It offers much higher bandwidth with low latency. The Intel
®
QuickPath Interconnect has an efficient architecture allowing more interconnect performance to be achieved in real systems. It has a snoop protocol optimized for low latency and high scalability, as well as packet and lane structures enabling quick completions of transactions. Reliability, availability, and serviceability features (RAS) are built into the architecture.
The physical connectivity of each interconnect link is made up of twenty differential signal pairs plus a differential forwarded clock. Each port supports a link pair consisting of two unidirectional links to complete the connection between two components. This supports traffic in both directions simultaneously. To facilitate flexibility and longevity, the interconnect is defined as having five layers: Physical, Link, Routing, Transport, and Protocol.
The Intel
®
QuickPath Interconnect includes a cache coherency protocol to keep the distributed memory and caching structures coherent during system operation. It supports both low-latency source snooping and a scalable home snoop behavior. The coherency protocol provides for direct cache-to-cache transfers for optimal latency.
3.2.2 Integrated Memory Controller (IMC) and Memory Subsystem
CPU 1
CPU 2
Integrated into the processor is a memory controller. Each processor provides four DDR3 channels that support the following:
Figure 18. Integrated Memory Controller Functional Block Diagram
Unbuffered DDR3 and registered DDR3 DIMMs
LR DIMM (Load Reduced DIMM) for buffered memory solutions demanding higher capacity memory subsystems
Independent channel mode or lockstep mode
Data burst length of eight cycles for all memory organization modes
Memory DDR3 data transfer rates of 800, 1066, 1333, 1600 and 1866* MT/s
64-bit wide channels plus 8-bits of ECC support for each channel
DDR3 standard I/O Voltage of 1.5 V and DDR3 Low Voltage of 1.35 V
1-Gb, 2-Gb, and 4-Gb DDR3 DRAM technologies supported for these devices: o UDIMM DDR3
– SR x8 and x16 data widths, DR – x8 data width o RDIMM DDR3
– SR,DR, and QR – x4 and x8 data widths o LRDIMM DDR3
– QR – x4 and x8 data widths with direct map or with rank multiplication
26 Intel order number G34153-003 Revision 1.2
Functional Architecture
3.2.2.1
Up to 8 ranks supported per memory channel, 1, 2 or 4 ranks per DIMM
Open with adaptive idle page close timer or closed page policy
Per channel memory test and initialization engine can initialize DRAM to all logical zeros with valid ECC (with or without data scrambler) or a predefined test pattern
Isochronous access support for Quality of Service (QoS)
Minimum memory configuration: independent channel support with 1 DIMM populated
Integrated dual SMBus* master controllers
Command launch modes of 1n/2n
RAS Support: o Rank Level Sparing and Device Tagging o Demand and Patrol Scrubbing o DRAM Single Device Data Correction (SDDC) for any single x4 or x8 DRAM device.
Independent channel mode supports x4 SDDC. x8 SDDC requires lockstep mode o Lockstep mode where channels 0 and 1 and channels 2 and 3 are operated in lockstep mode o Data scrambling with address to ease detection of write errors to an incorrect address. o Error reporting from Machine Check Architecture o Read Retry during CRC error handling checks by iMC o Channel mirroring within a socket
CPU1 Channel Mirror Pairs (A,B) and (C,D)
CPU2 Channel Mirror Pairs (E,F) and (G,H) o Error Containment Recovery
Improved Thermal Throttling with dynamic Closed Loop Thermal Throttling (CLTT)
Memory thermal monitoring support for DIMM temperature
*1866MT/s is only supported for E5-2600 v2 product family
Supported Memory
Table 3. UDIMM Support Guidelines
Ranks Per
DIMM and
Data Width
Memory Capacity Per
DIMM
1
Speed (MT/s) and Voltage Validated by
Slot per Channel (SPC) and DIMM Per Channel (DPC)
2,3
2 Slots per Channel
1DPC
1.35V 1.5V
Intel
®
Xeon
®
processor E5-2600 product family
1.35V
2DPC
1.5V
SRx8
ECC
DRx8
ECC
1GB
2GB
2GB
4GB
4GB
8GB
1066,1333
1066,1333
1066, 1333
1066, 1333
1066
1066
1066, 1333
1066, 1333
SRx8
ECC
1GB 2GB
Intel
®
Xeon
®
processor E5-2600 v2 product family
4GB 1066,1333
1066, 1333,
1600, 1866
1066, 1333 1066, 1333, 1600
DRx8
ECC
2GB 4GB 8GB 1066,1333
1066, 1333,
1066, 1333 1066, 1333, 1600
1600,1866
Notes:
1. Supported DRAM Densities are 1Gb, 2Gb and 4Gb. Only 2Gb and 4Gb are validated by Intel.
2. Command Address Timing is 1N for 1DPC and 2N for 2DPC.
Revision 1.2 Intel order number G34153-003 27
Functional Architecture
Supported and Validated
Supported but not Validate
Table 4. RDIMM Support Guidelines
Ranks Per DIMM and Data Width
SRx8
DRx8
Memory Capacity Per DIMM
1
Speed (MT/s) and Voltage Validated by
Slot per Channel (SPC) and DIMM Per Channel (DPC)
2
2 Slots per Channel
1DPC
1.35V 1.5V
Intel
®
Xeon
®
processor E5-2600 product family
1.35V
2DPC
1GB 2GB 4GB 1066, 1333
1.5V
1066, 1333, 1600
1066, 1333
1066, 1333, 1600
2GB 4GB 8GB 1066, 1333 1066, 1333, 1600
1066, 1333
1066, 1333, 1600
SRx4
DRx4
QRx4
QRx8
2GB
4GB
8GB
4GB
4GB
8GB
16GB
8GB
8GB
16GB
32GB
16GB
1066, 1333
1066, 1333
800
800
1066, 1333, 1600 1066, 1333 1066, 1333, 1600
1066, 1333, 1600
1066, 1333
1066, 1333, 1600
1066
800 800
1066
800 800
Intel
®
Xeon
®
processor E5-2600 v2 product family
SRx8
DRx8
SRx4
DRx4
1GB
2GB
2GB
4GB
2GB
4GB
4GB
8GB
4GB
8GB
8GB
16GB
1066, 1333
1066, 1333
1066, 1333
1066, 1333
1066, 1333, 1600,
1866
1066, 1333, 1600,
1866
1066, 1333, 1600,
1866
1066, 1333, 1600,
1866
1066 1333 1066, 1333, 1600
1066 1333
1066, 1333, 1600
1066 1333
1066, 1333, 1600
1066 1333 1066, 1333, 1600
QRx4
8GB 16GB 32GB 800
1066
800 800
QRx8
4GB 8GB 16GB 800
1066
800 800
Notes:
1. Supported DRAM Densities are 1Gb, 2Gb and 4Gb. Only 2Gb and 4Gb are validated by Intel
®
.
2. Command Address Timing is 1N.
3. QR RDIMM are supported but only validated by Intel/PMO in a homogenous environment. The coverage will have limited system level testing, no signal integrity testing, and no interoperability testing the passing QR
RDIMMs will be web posted.
Supported and Validated
Supported but not Validate
Supported w/Limited Validation
4
28 Intel order number G34153-003 Revision 1.2
Functional Architecture
Table 5. LRDIMM Support Guidelines
Ranks
Per
DIMM and
Data
Width
1
Memory Capacity
Per DIMM
2
1.35V
Speed (MT/s) and Voltage Validated by
Slot per Channel (SPC) and DIMM Per Channel (DPC)
3,4
2 Slots per Channel
1DPC 2DPC
1.5V 1.35V 1.5V
Intel
®
Xeon
®
processor E5-2600 product family
QRx4
(DDP)
5
QRx8
(P)
5
16GB 32GB
8GB 16GB
1066
1066
1066, 1333
1066, 1333
1066
1066
Intel
®
Xeon
®
processor E5-2600 v2 product family
QRx4
(DDP)
5
16GB 32GB
Supported and Validated
1066, 1333 1066, 1333 1066, 1333
QRx8
(P)
5
32GB
Notes:
64GB 1066 1066
1. Physical Rank is used to calculate DIMM Capacity.
2. Supported and validated DRAM Densities are 2Gb and 4Gb.
1066
3. Command Address Timing is 1N.
4. The speeds are estimated targets and will be verified through simulation.
5. DDP - Dual Die Package DRAM stacking. P
– Planer monolithic DRAM Die.
1066, 1333
1066, 1333
1066, 1333
1066
3.2.2.2 Memory Population Rules
Note: Although mixed DIMM configurations are supported, Intel only performs platform validation on systems that are configured with identical DIMMs installed.
Each processor provides four banks of memory, each capable of supporting up to 2 DIMMs.
DIMMs are organized into physical slots on DDR3 memory channels that belong to processor sockets.
The memory channels from processor socket 1 are identified as Channel A, B, C and D. The memory channels from processor socket 2 are identified as Channel E, F, G, and H.
The silk screened DIMM slot identifiers on the board provide information about the channel, and therefore the processor to which they belong. For example, DIMM_A1 is the first slot on Channel
A on processor 1; DIMM_E1 is the first DIMM socket on Channel E on processor 2.
The memory slots associated with a given processor are unavailable if the corresponding processor socket is not populated.
A processor may be installed without populating the associated memory slots provided a second processor is installed with associated memory.
In this case, the memory is shared by the processors.
However, the platform suffers performance degradation and latency due to the remote memory.
Processor sockets are self-contained and autonomous. However, all memory subsystem support
(such as Memory RAS, Error Management,) in the BIOS setup are applied commonly across processor sockets.
Revision 1.2 Intel order number G34153-003 29
Functional Architecture
On the Intel
®
Server Board S2600IP and Intel
®
Workstation Board W2600CR a total of 16 DIMM slots is provided (2 CPUs
– 4 Channels/CPU, 2 DIMMs/Channel). The nomenclature for DIMM sockets is detailed in the following table:
Table 6. DIMM Nomenclature
(0)
Channel A
Processor Socket 1
(1)
Channel B
(2)
Channel C
(3)
Channel D
A1 A2 B1 B2 C1 C2 D1 D2 E1
(0)
Channel E
E2 F1
Processor Socket 2
(1)
Channel F
(2)
Channel G
(3)
Channel H
F2 G1 G2 H1 H2
Figure 19. DIMM Slot Layout
The following are generic DIMM population requirements that generally apply to both the Intel
®
Server
Board S2600IP and Intel
®
Workstation Board W2600CR.
DIMM slots on any memory channel must be filled following the “farthest fill first” rule.
A maximum of 8 ranks can be installed on any one channel, counting all ranks in each DIMM on the channel.
DIMM types (UDIMM, RDIMM, LRDIMM) must not be mixed within or across processor sockets.
30 Intel order number G34153-003 Revision 1.2
Functional Architecture
Mixing ECC with non-ECC DIMMs (UDIMMs) is not supported within or across processor sockets.
Mixing Low Voltage (1.35V) DIMMs with Standard Voltage (1.5V) DIMMs is not supported within or across processor sockets.
Mixing DIMMs of different frequencies and latencies is not supported within or across processor sockets.
LRDIMM Rank Multiplication Mode and Direct Map Mode must not be mixed within or across processor sockets.
Only ECC UDIMMs support Low Voltage 1.35V operation.
QR RDIMMs may only be installed in DIMM Slot 1 or 2 on a channel.
2 DPC QR Low Voltage RDIMMs are not supported.
In order to install 3 QR LRDIMMs on the same channel, they must be operated with Rank
Multiplication as RM = 2.
RAS Modes Lockstep, Rank Sparing, and Mirroring are mutually exclusive in this BIOS. Only one operating mode may be selected, and it will be applied to the entire system.
If a RAS Mode has been configured, and the memory population will not support it during boot, the system will fall back to Independent Channel Mode and log and display errors
Rank Sparing Mode is only possible when all channels that are populated with memory meet the requirement of having at least 2 SR or DR DIMM installed, or at least one QR DIMM installed, on each populated channel.
Lockstep or Mirroring Modes require that for any channel pair that is populated with memory, the memory population on both channels of the pair must be identically sized.
DIMM population rules require that DIMMs within a channel be populated starting with the BLUE
DIMM slot or DIMM farthest from the processor in a “fill-farthest” approach. In addition, when populating a Quad-rank DIMM with a Single- or Dual-rank DIMM in the same channel, the
Quad-rank DIMM must be populated farthest from the processor. Note that Quad-rand DIMMs and UDIMMs are not allowed in three slots populated configurations. Intel MRC will check for correct DIMM placement.
3.2.2.3 Publishing System Memory
The BIOS displays the “Total Memory” of the system during POST if Display Logo is disabled in the BIOS setup. This is the total size of memory discovered by the BIOS during POST, and is the sum of the individual sizes of installed DDR3 DIMMs in the system.
The BIOS displays the “Effective Memory” of the system in the BIOS setup. The term Effective
Memory refers to the total size of all DDR3 DIMMs that are active (not disabled) and not used as redundant units.
The BIOS provides the total memory of the system in the main page of the BIOS setup. This total is the same as the amount described by the first bullet above.
If Quite Boot is disabled, the BIOS displays the total system memory on the diagnostic screen at the end of POST. This total is the same as the amount described by the first bullet above.
3.2.2.4 RAS Features
The server board supports the following memory RAS modes:
Independent Channel Mode
Rank Sparing Mode
Revision 1.2 Intel order number G34153-003 31
Functional Architecture
Mirrored Channel Mode
Lockstep Channel Mode
must be met at all times. Note that support of RAS modes that require matching DIMM population between channels (Mirrored and Lockstep) require that ECC DIMMs be populated. Independent Channel
Mode is the only mode that supports non-ECC DIMMs in addition to ECC DIMMs.
For RAS modes that require matching populations, the same slot positions across channels must hold the same DIMM type with regards to size and organization. DIMM timings do not have to match but timings will be set to support all DIMMs populated (that is, DIMMs with slower timings will force faster DIMMs to the slower common timing modes).
3.2.2.4.1 Independent Channel Mode
Channels can be populated in any order in Independent Channel Mode. All four channels may be populated in any order and have no matching requirements. All channels must run at the same interface frequency but individual channels may run at different DIMM timings (RAS latency, CAS Latency, and so forth).
3.2.2.4.2 Rank Sparing Mode
In Rank Sparing Mode, one rank is a spare of the other ranks on the same channel. The spare rank is held in reserve and is not available as system memory. The spare rank must have identical or larger memory capacity than all the other ranks (sparing source ranks) on the same channel. After sparing, the sparing source rank will be lost.
3.2.2.4.3 Mirrored Channel Mode
In Mirrored Channel Mode, the memory contents are mirrored between Channel 0 and Channel 2 and also between Channel 1 and Channel 3. As a result of the mirroring, the total physical memory available to the system is half of what is populated. Mirrored Channel Mode requires that Channel 0 and Channel 2, and Channel 1 and Channel 3 must be populated identically with regards to size and organization. DIMM slot populations within a channel do not have to be identical but the same DIMM slot location across Channel 0 and Channel 2 and across Channel
1 and Channel 3 must be populated the same.
3.2.2.4.4 Lockstep Channel Mode
In Lockstep Channel Mode, each memory access is a 128-bit data access that spans Channel 0 and Channel 1, and Channel 2 and Channel 3. Lockstep Channel mode is the only RAS mode that allows SDDC for x8 devices. Lockstep Channel Mode requires that Channel 0 and Channel
1, and Channel 2 and Channel 3 must be populated identically with regards to size and organization. DIMM slot populations within a channel do not have to be identical but the same
DIMM slot location across Channel 0 and Channel 1 and across Channel 2 and Channel 3 must be populated the same.
3.2.3 Processor Integrated I/O Module (IIO)
The processor’s integrated I/O module provides features traditionally supported through chipset components. The integrated I/O module provides the following features:
32 Intel order number G34153-003 Revision 1.2
Functional Architecture
3.2.3.1 PCI Express* Interfaces
The integrated I/O module incorporates the PCI Express* interface and supports up to 40 lanes of
PCI Express*. Following are key attributes of the PCI Express* interface:
Intel
®
Server Board S2600IP and Intel
®
Workstation Board W2600CR supports PCI-e slots from two processors:
From first processor:
Slot 1: PCIe Gen3 x16 connector
Slot 2: PCIe Gen3 x8 connector
Slot 3: PCIe Gen3 x16 connector
From second processor:
Slot 4: PCIe Gen3 x8 connector
Slot 5: PCIe Gen3 x16 connector
Slot 6: PCIe Gen3 x8 connector
Slot 7: PCIe Gen3 x16 connector
Slot 8: PCIe Gen2 x4 electrical with x8 physical connector.
Note: System will have video output on PCIe slots from first processor by default. If need add-in video card output on slots from second processor, please refer System Service guide to change Bios setup.
3.2.3.2 DMI2 Interface to the PCH
The platform requires an interface to the legacy Southbridge (PCH) which provides basic legacy functions required for the server platform and operating systems. Since only one PCH is required and allowed for the system, any sockets which do not connect to PCH would use this port as a standard x4 PCI Express* 2.0 interface.
3.2.3.3 Integrated IOAPIC
Provides support for PCI Express* devices implementing legacy interrupt messages without interrupt sharing.
3.2.3.4 Non Transparent Bridge
PCI Express* non-transparent bridge (NTB) acts as a gateway that enables high performance, low overhead communication between two intelligent subsystems; the local and the remote subsystems.
The NTB allows a local processor to independently configure and control the local subsystem, provides isolation of the local host memory domain from the remote host memory domain while enabling status and data exchange between the two domains.
3.2.3.5 4.2.3.1.5 Intel
®
Used for efficient, high bandwidth data movement between two locations in memory or from memory to I/O.
Revision 1.2 Intel order number G34153-003 33
Functional Architecture
3.3 Intel
®
The Intel
®
C600-A Chipset in the Intel
®
Server Board S2600IP and Intel provide a connection point between various I/O components and Intel
®
®
Workstation Board W2600CR
Xeon Sandy Bridge-EP processors, which includes the following core platform functions:
Digital Media Interface (DMI)
PCI Express* Interface
Serial ATA (SATA) Controller
Serial Attached SCSI (SAS)/SATA Controller
AHCI
Rapid Storage Technology
PCI Interface
Low Pin Count (LPC) Interface
Serial Peripheral Interface (SPI)
Compatibility Modules (DMA Controller, Timer/Counters, Interrupt Controller)
Advanced Programmable Interrupt Controller (APIC)
Universal Serial Bus (USB) Controllers
Gigabit Ethernet Controller
RTC
GPIO
Enhanced Power Management
Intel
®
Active Management Technology (Intel
®
AMT)
Manageability
System Management Bus (SMBus* 2.0)
Integrated NVSRAM controller
Virtualization Technology for Directed I/O (Intel
®
VT-d)
JTAG Boundary-Scan
KVM/Serial Over LAN (SOL) Function
3.3.1 Digital Media Interface (DMI)
Digital Media Interface (DMI) is the chip-to-chip connection between the processor and The Intel
®
C600-A
Chipset. This high-speed interface integrates advanced priority-based servicing allowing for concurrent traffic and true isochronous transfer capabilities. Base functionality is completely software-transparent, permitting current and legacy software to operate normally.
3.3.2 PCI Express* Interface
The Intel
®
C600-A Chipset provides up to 8 PCI Express* Root Ports, supporting the PCI Express* Base
Specification, Revision 2.0. Each Root Port x1 lane supports up to 5 Gb/s bandwidth in each direction (10
Gb/s concurrent). PCI Express* Root Ports 1-4 or Ports 5-8 can independently be configured to support four x1s, two x2s, one x2 and two x1s, or one x4 port widths.
3.3.3 Serial ATA (SATA) Controller
The Intel
®
C600-A Chipset has two integrated SATA host controllers that support independent DMA operation on up to six ports and supports data transfer rates of up to 6.0 Gb/s (600 MB/s) on up to two
34 Intel order number G34153-003 Revision 1.2
Functional Architecture ports (Port 0 and 1 Only) while all ports support rates up to 3.0 Gb/s (300 MB/s) and up to 1.5 Gb/s (150
MB/s). The SATA controller contains two modes of operation
– a legacy mode using I/O space, and an
AHCI mode using memory space. Software that uses legacy mode will not have AHCI capabilities.
The Intel
®
C600-A Chipset supports the Serial ATA Specification, Revision 3.0. The Intel
®
C600-A
Chipset also supports several optional sections of the Serial ATA II: Extensions to Serial ATA 1.0
Specification, Revision 1.0 (AHCI support is required for some elements).
3.3.4 Serial Attached SCSI (SAS)/SATA (SCU) Controller
The Intel
®
C600-A Chipset supports up to 8 SAS ports that are compliant with SAS 2.0 Specification and all ports support rates up to 3.0 Gb/s. All 8 ports are also independently configurable and compliant with
SATA Gen2 and support data transfer rates of up to 3.0 Gb/s.
SAS/SATA controller is only available on specific Intel
®
C600-A Chipset SKUs with optional RAID C600
Upgrade key. Certain SKUs are also limited to support 4 of 8 SAS/SATA ports only. Please refer details below:
Note: SAS/SATA (SCU) port 0-3 is by default enabled while port 4-7 is disabled.
Table 7. Intel
®
RAID C600 Upgrade Key Options
Intel RAID C600 Upgrade Key Options
(Product Codes)
Default
– No option key installed
RKSATA4R5
RKSATA8
RKSATA8R5
RKSAS4
RKSAS4R5
RKSAS8
RKSAS8R5
Key Color
N/A
Black
Blue
White
Green
Yellow
Orange
Purple
Description
4 Port SATA with Intel
®
ESRT RAID 0,1,10 and Intel
®
RSTe RAID 0,1,5,10
4 Port SATA with Intel
®
ESRT2 RAID 0,1, 5, 10 and Intel
®
RSTe RAID 0,1,5,10
8 Port SATA with Intel
®
ESRT2 RAID 0,1, 10 and Intel
®
RSTe RAID 0,1,5,10
8 Port SATA with Intel
®
ESRT2 RAID 0,1, 5, 10 and Intel
®
RSTe RAID 0,1,5,10
4 Port SAS with Intel
®
ESRT2 RAID 0,1, 10 and Intel
®
RSTe RAID 0,1,10
4 Port SAS with Intel
®
ESRT2 RAID 0,1, 5, 10 and Intel
®
RSTe RAID 0,1,10
8 Port SAS with Intel
®
ESRT2 RAID 0,1, 10 and Intel
®
RSTe RAID 0,1,10
8 Port SAS with Intel
®
ESRT2 RAID 0,1, 5, 10 and Intel
®
RSTe RAID 0,1,10
Additional information for the on-board RAID features and functionality can be found in the Intel
®
RAID Software User
’s Guide (Intel Document Number D29305-019).
3.3.5 AHCI
The Intel
®
C600-A Chipset provides hardware support for Advanced Host Controller Interface (AHCI), a standardized programming interface for SATA host controllers. Platforms supporting AHCI may take advantage of performance features. AHCI also provides usability enhancements such as Hot-Plug. AHCI requires appropriate software support (for example, an AHCI driver) and for some features, hardware support in the SATA device or additional platform hardware.
3.3.6 Rapid Storage Technology
The Intel
®
C600-A Chipset provides support for Intel
®
Rapid Storage Technology, providing both AHCI and integrated RAID functionality. The RAID capability provides high-performance RAID 0, 1, 5 and 10 functionality on the Intel
®
C600-A chipset. Matrix RAID support is provided to allow multiple RAID levels to
Revision 1.2 Intel order number G34153-003 35
Functional Architecture be combined on a single set of hard drives, such as RAID 0 and RAID 1 on two disks. Other RAID features include hot-spare support, SMART alerting, and RAID 0 auto replace.
3.3.7 PCI Interface
The Intel
®
C600-A chipset PCI interface provides a 33 MHz, Revision 2.3 implementation. The Intel
®
C600-A chipset integrates a PCI arbiter that supports up to four external PCI bus masters in addition to the internal Intel
®
C600-A chipset requests. This allows for combinations of up to four PCI down devices and PCI slots.
3.3.8 Low Pin Count (LPC) Interface
The Intel
®
C600-A chipset implements an LPC Interface as described in the LPC 1.1 Specification. The
Low Pin Count (LPC) bridge function of the Intel
®
C600-A resides in PCI Device 31: Function 0. In addition to the LPC bridge interface function, D31:F0 contains other functional units including DMA, interrupt controllers, timers, power management, system management, GPIO, and RTC.
3.3.9 Serial Peripheral Interface (SPI)
The Intel
®
C600-A chipset implements an SPI Interface as an alternative interface for the BIOS flash device. The SPI flash is required to support Gigabit Ethernet and Intel
®
Active Management Technology.
The Intel
®
C600-A chipset supports up to two SPI flash devices with speeds up to 50 MHz.
3.3.10 Compatibility Modules (DMA Controller, Timer/Counters, Interrupt Controller)
The DMA controller incorporates the logic of two 82C37 DMA controllers, with seven independently programmable channels. The Intel
®
C600-A chipset’s DMA controller.
C600-A chipset supports LPC DMA through the Intel
®
The timer/counter block contains three counters that are equivalent in function to those found in one
82C54 programmable interval timer. These three counters are combined to provide the system timer function, and speaker tone.
The Intel
®
C600-A chipset provides an ISA-Compatible Programmable Interrupt Controller (PIC) that incorporates the functionality of two 82C59 interrupt controllers. In addition, the Intel
®
C600-A chipset supports a serial interrupt scheme.
All of the registers in these modules can be read and restored. This is required to save and restore system state after power has been removed and restored to the platform.
3.3.11 Advanced Programmable Interrupt Controller (APIC)
In addition to the standard ISA compatible Programmable Interrupt controller (PIC) described in the previous section, the Intel
®
C600-A incorporates the Advanced Programmable Interrupt Controller (APIC).
3.3.12 Universal Serial Bus (USB) Controllers
The Intel
®
C600-A chipset has up to two Enhanced Host Controller Interface (EHCI) host controllers that support USB high-speed signaling. High-speed USB 2.0 allows data transfers up to 480 Mb/s which is 40 times faster than full-speed USB. The Intel
®
C600-A chipset supports up to fourteen USB 2.0 ports. All fourteen ports are high-speed, full-speed, and low-speed capable.
3.3.13 Gigabit Ethernet Controller
The Gigabit Ethernet Controller provides a system interface using a PCI function. The controller provides a full memory-mapped or IO mapped interface along with a 64 bit address master support for systems using more than 4 GB of physical memory and DMA (Direct Memory Addressing) mechanisms for high performance data transfers. Its bus master capabilities enable the component to process high-level
36 Intel order number G34153-003 Revision 1.2
Functional Architecture commands and perform multiple operations; this lowers processor utilization by off-loading communication tasks from the processor. Two large configurable transmit and receive FIFOs (up to 20 KB each) help prevent data underruns and overruns while waiting for bus accesses. This enables the integrated LAN controller to transmit data with minimum interframe spacing (IFS).
The LAN controller can operate at multiple speeds (10/100/1000 MB/s) and in either full duplex or half duplex mode. In full duplex mode the LAN controller adheres with the IEEE 802.3x Flow Control
Specification. Half duplex performance is enhanced by a proprietary collision reduction mechanism.
3.3.14 RTC
The Intel
®
C600-A chipset contains a real-time clock with 256 bytes of battery-backed RAM. The real-time clock performs two key functions: keeping track of the time of day and storing system data. The RTC operates on a 32.768 KHz crystal and a 3 V battery.
3.3.15 GPIO
Various general purpose inputs and outputs are provided for custom system design. The number of inputs and outputs varies depending on the Intel
®
C600-A chipset configuration.
3.3.16 Enhanced Power Management
The Intel
®
C600-A chipset’s power management functions include enhanced clock control and various low-power (suspend) states (for example, Suspend-to-RAM and Suspend-to-Disk). A hardware-based thermal management circuit permits software-independent entrance to low-power states. The Intel
®
C600-
A chipset contains full support for the Advanced Configuration and Power Interface (ACPI) Specification,
Revision 4.0a.
3.3.17 Manageability
In addition to Intel AMT the Intel
®
C600-A chipset integrates several functions designed to manage the system and lower the total cost of ownership (TCO) of the system. These system management functions are designed to report errors, diagnose the system, and recover from system lockups without the aid of an external microcontroller.
3.3.18 System Management Bus (SMBus* 2.0)
The Intel
®
C600-A chipset contains a SMBus* Host interface that allows the processor to communicate with SMBus* slaves. This interface is compatible with most I2C devices. Special I2C commands are implemented.
The Intel
®
C600-A chipset’s SMBus* host controller provides a mechanism for the processor to initiate communications with SMBus* peripherals (slaves). Also, the Intel
®
C600-A chipset supports slave functionality, including the Host Notify protocol. Hence, the host controller supports eight command protocols of the SMBus* interface (see System Management Bus (SMBus*) Specification, Version 2.0):
Quick Command, Send Byte, Receive Byte, Write Byte/Word, Read Byte/Word, Process Call, Block
Read/Write, and Host Notify.
The Intel
®
C600-A chipset’s SMBus* also implements hardware-based Packet Error Checking for data robustness and the Address Resolution Protocol (ARP) to dynamically provide address to all SMBus* devices.
3.3.19 Integrated NVSRAM controller
The Intel
®
C600-A chipset has an integrated NVSRAM controller that supports up to 32KB external device.
The host processor can read and write data to the NVSRAM component.
Revision 1.2 Intel order number G34153-003 37
Functional Architecture
3.3.20
The Intel
®
C600-A chipset provides hardware support for implementation of Intel
Technology with Directed I/O (Intel
®
®
Virtualization
VT-d). Intel VT-d consists of technology components that support the virtualization of platforms based on Intel
®
Architecture Processors. Intel VT-d Technology enables multiple operating systems and applications to run in independent partitions. A partition behaves like a virtual machine (VM) and provides isolation and protection across partitions. Each partition is allocated its own subset of host physical memory.
3.3.21 JTAG Boundary-Scan
The Intel
®
C600-A chipset adds the industry standard JTAG interface and enables Boundary-Scan in place of the XOR chains used in previous generations of chipsets. Boundary-Scan can be used to ensure device connectivity during the board manufacturing process. The JTAG interface allows system manufacturers to improve efficiency by using industry available tools to test the Intel
®
C600-A chipset on an assembled board. Since JTAG is a serial interface, it eliminates the need to create probe points for every pin in an XOR chain. This eases pin breakout and trace routing and simplifies the interface between the system and a bed-of-nails tester.
3.3.22 KVM/Serial Over Lan (SOL) Function
These functions support redirection of keyboard, mouse, and text screen to a terminal window on a remote console. The keyboard, mouse, and text redirection enables the control of the client machine through the network. Text, mouse, and keyboard redirection allows the remote machine to control and configure the client by entering BIOS setup. The KVM/SOL function emulates a standard PCI serial port and redirects the data from the serial port to the management console using LAN. KVM has additional requirements of internal graphics and SOL may be used when KVM is not supported.
3.3.23 On-board SAS/SATA Support and Options
The Intel
®
C600 chipset provides storage support by two integrated controllers: AHCI and SCU. By default the server board will support up to 10 SATA ports: Two white 6Gb/sec SATA ports from the
AHCI controller labeled as “SATA_0” and “SATA_1” and two MINISAS 3Gb/sec SATA/SAS ports routed from the SCU controller labeled as “SCU0 (PORT0-3) and “SCU1(PORT4-7).
The SCU Port can be configured with the two embedded software RAID options:
Intel
®
Embedded Server RAID Technology 2 (ESRT2) based on LSI* MegaRAID SW
RAID technology supporting RAID levels 0,1, and 10.
Intel
®
Rapid Storage Technology (RSTe) supporting RAID levels 0, 1, 5, and 10.
3.3.23.1 Intel
®
Features of the embedded software RAID option Intel
®
Embedded Server RAID Technology 2
(ESRT2) include the following:
Based on LSI* MegaRAID Software Stack
Software RAID with system providing memory and CPU utilization
Supported RAID Levels
– 0,1,5,10
4 and 8 Port SATA RAID 5 support provided with appropriate Intel
®
RAID C600
Upgrade Key
4 and 8 Port SAS RAID 5 support provided with appropriate Intel
®
RAID C600
Upgrade Key
Maximum drive support = 8
Open Source Compliance = Binary Driver (includes Partial Source files) or Open Source
38 Intel order number G34153-003 Revision 1.2
Functional Architecture
using MDRAID layer in Linux.
OS Support = Windows 7*, Windows 2008*, Windows 2003*, RHEL*, SLES, other Linux* variants using partial source builds.
Utilities = Windows* GUI and CLI, Linux GUI and CLI, DOS CLI, and EFI CLI
3.3.23.2 Intel
®
Features of the embedded software RAID option Intel
®
Rapid Storage Technology (RSTe) include the following:
Software RAID with system providing memory and CPU utilization
Supported RAID Levels
– 0,1,5,10 o 4 Port SATA RAID 5 available standard (no option key required) o 8 Port SATA RAID 5 support provided with appropriate Intel
®
RAID C600 Upgrade
Key o No SAS RAID 5 support
Maximum drive support = 32 (in arrays with 8 port SAS), 16 (in arrays with 4 port SAS),
128 (JBOD)
Open Source Compliance = Yes (uses MDRAID)
OS Support = Windows 7*, Windows 2008*, Windows 2003*, RHEL* 6.2 and later,
SLES* 11 w/SP2 and later, VMWare* 5.x.
Utilities = Windows* GUI and CLI, Linux CLI, DOS CLI, and EFI CLI
Uses Matrix Storage Manager for Windows*
MDRAID supported in Linux* (does not require a driver)
Note: No boot drive support to targets attached through SAS expander card
3.4 PCI Subsystem
The primary I/O buses for the Intel
®
Server Board S2600IP and Intel
®
Workstation Board W2600CR are
PCI Express* Gen3 with six independent PCI bus segments. The following tables list the characteristics of the PCI bus segments.
Table 8. Intel
®
Server Board S2600IP/Workstation Board W2600CR PCI Bus Segment
Characteristics
Voltage
3.3 V x16
Width
3.3 V
3.3 V
X8 or none
(with mux) x16 or x8(with mux)
Speed
32 GB/S PCI
Type
Express*
Gen3
16 GB/S or none
PCI
Express*
Gen3
32 GB/S or
16 GB/S
PCI
Express*
Gen3
PCI I/O Card Slots
X16 PCI Express* Gen3 throughput to Slot1 (x16 mechanically) x8 PCI Express* Gen3 throughput to Slot 2 (x8 mechanically) x16 PCI Express* Gen3 throughput to Slot 3 (x16 mechanically)
Revision 1.2 Intel order number G34153-003 39
Functional Architecture
3.3 V
3.3 V
3.3 V
3.3 V
X8 or none
(with mux) x16 or x8(with mux)
X8 or none
(with mux) x16 or x8(with mux)
16 GB/S or none
PCI
Express*
Gen3
32 GB/S or
16 GB/S
PCI
Express*
Gen3
16 GB/S or none
PCI
Express*
Gen3
32 GB/S or
16 GB/S
PCI
Express*
Gen3 x8 PCI Express* Gen3 throughput to Slot 4 (x8 mechanically, Non-
Persistent)
X16 PCI Express* Gen3 throughput to Slot 5 (x16 mechanically, Non-
Persistent) x8 PCI Express* Gen3 throughput to Slot 6 (x8 mechanically, Non-
Persistent)
X16 PCI Express* Gen3 throughput to Slot 7 (x16 mechanically, Non-
Persistent)
3.3 V X4 4 GB/S PCI
Express*
Gen2
X4 PCI Express* Gen2 throughput to Slot 8 (x8 mechanically, Non-
Persistent)
3.5 Network Interface Controller
The Intel
®
Server Board S2600IP and Workstation Board S2600CR has a Intel
®
Ethernet Controller I350
GbE Controller. The controller supports PCI Express* PCIe v2.0 (5GT/s and 2.5GT/s). The controller enables four-port or two-port 1000BASE-T implementations using integrated PHY’s. The controller supports VMDq, SR-IOV, EEE, and DMA Coalescing.
3.5.1 Network Interface
Network connectivity is provided by means of an onboard Intel
®
Ethernet Controller 1350-AM4 providing up to four 10/100/1000 Mb Ethernet ports.
On the Intel
®
Server Board S2600IP, four external 10/100/1000 Mb RJ45 Ethernet ports are provided. On the Intel
®
Workstation Board W2600CR, two external 10/100/1000 Mb RJ45 Ethernet ports are provided.
Each Ethernet port drives two LEDs located on each network interface connector. The LED at the right of the connector is the link/activity LED and indicates network connection when on, and transmit/receive activity when blinking. The LED at the left of the connector indicates link speed as defined in the following table.
40 Intel order number G34153-003 Revision 1.2
Functional Architecture
LED Color
Green/Amber (Right)
Green (Left)
Off
Amber
Green
On
Blinking
LED State NIC State
10 Mbps
100 Mbps
1000 Mbps
Active Connection
Transmit/Receive activity
Figure 20. External RJ45 NIC Port LED Definition
3.6 I/O Module Support (not avaiable for Intel
®
Server Board S2600IP4L and
Intel
®
Workstation Board W2600CR2L)
To broaden the standard on-board feature set, the server board supports the option of adding a single I/O module providing external ports for a variety of networking interfaces. The I/O module attaches to a high density 80pin connector on the server board labeled “IO_Module”.
Supported I/O modules include:
Revision 1.2 Intel order number G34153-003 41
Functional Architecture
Product Code and iPN
AXX10GBNIAIOM
MM# 917905
AXX10GBTWLIOM
MM# 917907
AXX1FDRIBIOM
MM# 918607
AXX4P1GBPWLIOM
MM# 917911
AXXIOMKIT
MM# 920852
Description
Dual SFP+ port 10GbE IO Module based on Intel
®
82599 10GbE Ethernet Controller
Dual RJ45 Port, 10GBASE-T IO Module, based on Intel
®
I350 Ethernet chipset
Single Port, FDR speed Infiniband* module, with QSFP connector.
Quad Port 1GbE 1o Module based on Intel
I/O Module Cable and Brackets
®
Ethernet Controller I350
Figure 21. Supported I/O Module Options
Notes:
1. I/O Module cable and Brackets accessory is necessary to support I/O module on Intel
®
Server Board
S2600IP.
2. IOM connector only supports PCIe Gen1 Speed
3.7 SAS ROC Module Support
The system provides support for Intel
®
Integrated RAID mezzanine modules that utilize a high density 80pin connector (labeled “SAS_MOD”) on the server board.
42 Intel order number G34153-003 Revision 1.2
Features of this option include:
Does not utilize a PCIe slot
SKU options to support full or entry level hardware RAID
4 or 8 port and SAS/SATA or SATA –only ROC options
Functional Architecture
SKU options to support 512MB or 1GB embedded memory
Intel designed flash + optional support for super-cap backup (Maintenance Free Back Up) or improved Lithium Polymer battery
Table 9. Supported Intel
®
Integrated RAID Modules
External Name Description Product Code
Intel
®
Integrated RAID Module
RMS25CB080
Intel
®
Integrated RAID Module
RMS25CB040
8 Port SAS-2.1, Full HW RAID, 1GB, Mezz Slot
RAID Levels 0,1,10, 5, 50, 6, 60
4 Port SAS-2.1, Full HW RAID, 1GB, Mezz Slot
RAID Levels 0,1,10, 5, 50, 6, 60
RMS25CB080
RMS25CB040
Intel
®
Integrated RAID Module
RMT3CB080
Intel
®
Integrated RAID Module
RMS25KB080
8 Port SATA-3, Full HW RAID, 512MB, Mezz
Slot
RAID Levels 0,1,10, 5, 50, 6, 60
RMT3CB080
8 Port SAS-2.1, Entry-level HW RAID, Mezz Slot RMS25KB080
RAID Levels 0,1,1E
Intel
®
Integrated RAID Module
RMS25KB040
4 Port SAS-2.1, Entry-level HW RAID, Mezz Slot RMS25KB040
RAID Levels 0,1,1E
For additional product information, please refer the following Intel
®
document:
Intel
®
Integrated RAID Module RMS25PB080, RMS25PB040, RMS25CB080, and
RMS25CB040 Hardware User’s Guide – Intel Order Number G37519-003.
3.8 HD Audio Support (Intel
®
Workstation Board W2600CR Only)
The Intel
®
Workstation Board W2600CR support 7.1 HD Audio through the High Definition Audio Codec
Realtek* ALC889. The ALC889 provides ten DAC channels that simultaneously support 7.1 sound playback, plus two channels of independent stereo sound output (multiple streaming) through the front panel stereo outputs. Also supports two channels of S/PDIF In/Out (W2600CR only supports 1 S/PDIF
Out port) and two channels of Microphone In (Front/Rear). The ALC889 is driven by the Intel
®
HD Audio
Interface (Azalia) from Intel
®
C600-A chipset.
Revision 1.2 Intel order number G34153-003 43
Functional Architecture
Table 10. Standard Speaker Channels
Channel name Identifier
Front Left
Front Right
SPEAKER_FRONT_LEFT
SPEAKER_FRONT_RIGHT
Front Center SPEAKER_FRONT_CENTER
Low Frequency (Subwoofer) SPEAKER_LOW_FREQUENCY
Back Left
Back Right
Side Left
Side Right
SPEAKER_BACK_LEFT
SPEAKER_BACK_RIGHT
SPEAKER_SIDE_LEFT
SPEAKER_SIDE_RIGHT
1.0
Mono
No
No
Yes
No
No
No
No
No
2.0
Stereo
Yes
Yes
No
No
No
No
No
No
5.1
Surround
Yes
Yes
Yes
Yes
Yes
Yes
No
No
3.9 USB3.0 Support (Intel
®
Workstation Board W2600CR Only)
The Intel
®
Workstation Board W2600CR supports two USB3.0 SuperSpeed* ports, which is required as a standard Workstation feature. The TI 2 port USB3.0 discrete host controller TUSB7320 is used to meet this requirement. The TUSB7320 USB3.0 host controller complies with Universal Serial Bus 3.0
Specification and Intel’s eXtensible Host Controller Interface (xHCI).
7.1
Surround
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
44
Figure 22. USB3.0 Discrete Host Controller Block Diagram
Intel order number G34153-003 Revision 1.2
Functional Architecture
3.10 IEEE1394b Support (Intel
®
Workstation Board W2600CR Only)
Intel
®
Workstation Board W2600CR offers one front panel IEEE 1394b port from a discrete controller
(Texas Instruments XIO2221).The XIO2221 uses a PCIe x1 Gen 1 upstream interface from Intel
®
C600-A chipset. When connected to 1394b compliant devices, the XIO2221 can transfer data at speeds of up to
800 Mbps. The Intel
®
Workstation Board W2600CR includes an internal 1394b connector that allows for a front panel 1394b cable attach.
Revision 1.2
Figure 23. IEEE 1394b Discrete Host Controller Block Diagram
Intel order number G34153-003 45
Platform Management Overview
4. Platform Management Overview
4.1 Server Management Function Architecture
4.1.1 Feature Support
4.1.1.1 IPMI 2.0 Features
The IPMI 2.0 features are as follows:
1. Baseboard management controller (BMC)
2. IPMI Watchdog timer
3. Messaging support, including command bridging and user/session support
4. Chassis device functionality, including power/reset control and BIOS boot flags support
5. Event receiver device: The BMC receives and processes events from other platform subsystems.
6. Field Replaceable Unit (FRU) inventory device functionality: The BMC supports access to system
FRU devices using IPMI FRU commands.
7. System Event Log (SEL) device functionality: The BMC supports and provides access to a SEL.
8. Sensor Data Record (SDR) repository device functionality: The BMC supports storage and access of system SDRs.
9. Sensor device and sensor scanning/monitoring: The BMC provides IPMI management of sensors. It polls sensors to monitor and report system health.
10. IPMI interfaces
11. Host interfaces include system management software (SMS) with receive message queue support, and server management mode (SMM)
12. IPMB interface
13. LAN interface that supports the IPMI-over-LAN protocol Remote Management Control Protocol
(RMCP, RMCP+)
14. Serial-over-LAN (SOL)
15. ACPI state synchronization: The BMC tracks ACPI state changes that are provided by the BIOS.
16. BMC self test: The BMC performs initialization and run-time self-tests and makes results available to external entities.
See also the Intelligent Platform Management Interface Specification Second Generation, Version 2.0.
4.1.1.2 Non IPMI features
The BMC supports the following non-IPMI features. This list does not preclude support for future enhancements or additions.
In-circuit BMC firmware update
Fault resilient booting (FRB): FRB2 is supported by the watchdog timer functionality.
Chassis intrusion detection (dependent on platform support)
Basic fan control using Control version 2 SDRs
Fan redundancy monitoring and support
Power supply redundancy monitoring and support
Hot-swap fan support
Acoustic management: Support for multiple fan profiles
46 Intel order number G34153-003 Revision 1.2
Platform Management Overview
Signal testing support: The BMC provides test commands for setting and getting platform signal states.
The BMC generates diagnostic beep codes for fault conditions.
System GUID storage and retrieval
Front panel management: The BMC controls the system status LED and chassis ID LED. It supports secure lockout of certain front panel functionality and monitors button presses. The chassis ID LED is turned on using a front panel button or a command.
Power state retention
Power fault analysis
Intel
®
Light-Guided Diagnostics
Power unit management: Support for power unit sensor. The BMC handles power-good dropout conditions.
DIMM temperature monitoring: New sensors and improved acoustic management using closedloop fan control algorithm taking into account DIMM temperature readings.
Address Resolution Protocol (ARP): The BMC sends and responds to ARPs (supported on embedded NICs).
Dynamic Host Configuration Protocol (DHCP): The BMC performs DHCP (supported on embedded NICs).
Platform environment control interface (PECI) thermal management support
E-mail alerting
Embedded web server
Integrated KVM.
Integrated Remote Media Redirection
Lightweight Directory Access Protocol (LDAP) support
Intel
®
Intelligent Power Node Manager support
4.1.1.3 New Manageability Features
Intel
®
S1400/S1600/S2400/S2600 Server Platforms offer a number of changes and additions to the manageability features that are supported on the previous generation of servers. The following is a list of the more significant changes that are common to this generation Integrated BMC based Intel
®
Server boards:
Sensor and SEL logging additions/enhancements (for example, additional thermal monitoring capability)
SEL Severity Tracking and the Extended SEL
Embedded platform debug feature which allows capture of detailed data for later analysis.
Provisioning and inventory enhancements: o Inventory data/system information export (partial SMBIOS table)
Enhancements to fan speed control.
DCMI 1.1 compliance (product-specific).
Support for embedded web server UI in Basic Manageability feature set.
Enhancements to embedded web server o Human-readable SEL o Additional system configurability o Additional system monitoring capability
Revision 1.2 Intel order number G34153-003 47
Platform Management Overview o Enhanced on-line help
Enhancements to KVM redirection o Support for higher resolution
Support for EU Lot6 compliance
Management support for PMBus* rev1.2 compliant power supplies
BMC Data Repository (Managed Data Region Feature)
Local Control Display Panel
System Airflow Monitoring
Exit Air Temperature Monitoring
Ethernet Controller Thermal Monitoring
Global Aggregate Temperature Margin Sensor
Memory Thermal Management
Power Supply Fan Sensors
Energy Star Server Support
Smart Ride Through (SmaRT)/ Closed Loop System Throttling (CLST)
Power Supply Cold Redundancy
Power Supply FW Update
Power Supply Compatibility Check
BMC FW reliability enhancements: o Redundant BMC boot blocks to avoid possibility of a corrupted boot block resulting in a scenario that prevents a user from updating the BMC. o BMC System Management Health Monitoring
4.1.2 Basic and Advanced Features
The bellowing table lists basic and advanced feature support. Individual features may vary by platform.
See the appropriate Platform Specific EPS addendum for more information.
Table 11. Basic and Advanced Features
Feature
IPMI 2.0 Feature Support
In-circuit BMC Firmware Update
FRB 2
Chassis Intrusion Detection
Fan Redundancy Monitoring
Hot-Swap Fan Support
Acoustic Management
Diagnostic Beep Code Support
Power State Retention
ARP/DHCP Support
X
X
X
X
Basic
X
X
X
X
X
X
Advanced
X
X
X
X
X
X
X
X
X
X
48 Intel order number G34153-003 Revision 1.2
Platform Management Overview
Feature
PECI Thermal Management Support
E-mail Alerting
Embedded Web Server
SSH Support
Integrated KVM
Integrated Remote Media Redirection
Lightweight Directory Access Protocol (LDAP)
Intel
®
Intelligent Power Node Manager Support
SMASH CLP
X
X
X
Basic
X
X
X
X
Advanced
X
X
X
X
X
X
X
X
X
4.1.3
4.1.3.1
Integrated BMC Hardware: Emulex* Pilot III
Emulex* Pilot III Baseboard Management Controller Functionality
The Integrated BMC is provided by an embedded ARM9 controller and associated peripheral functionality that is required for IPMI-based server management. Firmware usage of these hardware features is platform dependent.
The following is a summary of the Integrated BMC management hardware features that comprise the
BMC:
400MHz 32-bit ARM9 processor with memory management unit (MMU)
Two independent10/100/1000 Ethernet Controllers with Reduced Media Independent Interface
(RMII)/ Reduced Gigabit Media Independent Interface (RGMII) support
DDR2/3 16-bit interface with up to 800 MHz operation
16 10-bit ADCs
Sixteen fan tachometers
Eight Pulse Width Modulators (PWM)
Chassis intrusion logic
JTAG Master
Eight I
2
C interfaces with master-slave and SMBus* timeout support. All interfaces are SMBus* 2.0 compliant.
Parallel general-purpose I/O Ports (16 direct, 32 shared)
Serial general-purpose I/O Ports (80 in and 80 out)
Three UARTs
Platform Environmental Control Interface (PECI)
Six general-purpose timers
Interrupt controller
Multiple Serial Peripheral Interface (SPI) flash interfaces
NAND/Memory interface
Sixteen mailbox registers for communication between the BMC and host
LPC ROM interface
BMC watchdog timer capability
SD/MMC card controller with DMA support
LED support with programmable blink rate controls on GPIOs
Port 80h snooping capability
Secondary Service Processor (SSP), which provides the HW capability of offloading time critical processing tasks from the main ARM core.
Emulex* Pilot III contains an integrated SIO, KVMS subsystem and graphics controller with the following features:
Revision 1.2 Intel order number G34153-003 49
Platform Management Overview
4.1.3.1.1 Super I/O (SIO)
The BMC integrates a super I/O module with the following features:
Keyboard Style/BT interface for BMC support
Two Fully Functional Serial Ports, compatible with the 16C550
Serial IRQ Support
Up to 16 Shared GPIO available for host processor
Programmable Wake-up Event Support
Plug and Play Register Set
Power Supply Control
4.1.3.1.2 Graphics Controller
The graphics controller provides the following features:
Integrated Graphics Core with 2D Hardware accelerator
High speed Integrated 24-bit RAMDAC
DDR-2/3 memory interface with 16Mbytes of memory allocated and reported for graphics memory.
4.1.3.1.3 Remote Keyboard, Video, Mouse, and Storage (KVMS )
The Integrated BMC contains a remote KVMS subsystem with the following features:
USB 2.0 interface for Keyboard, Mouse and Remote storage such as CD/DVD ROM and floppy
USB 1.1/USB 2.0 interface for PS2 to USB bridging, remote Keyboard and Mouse
Hardware Based Video Compression and Redirection Logic
Supports both text and Graphics redirection
Hardware assisted Video redirection using the Frame Processing Engine
Direct interface to the Integrated Graphics Controller registers and Frame buffer
Hardware-based encryption engine
50 Intel order number G34153-003 Revision 1.2
Platform Management Overview
Figure 24. Integrated BMC Hardware
4.2 Server Management Functional Specifications
4.2.1 BMC Internal Timestamp Clock
The BMC maintains an internal timestamp clock that is used by various BMC subsystems, for example, time stamping SEL entries. As part of BMC initialization after AC power is applied or the BMC is reset, the
BMC initializes this internal clock to the value retrieved from the SSB component’s RTC from a SMBus* slave read operation. This is the system RTC and is on the battery power well so it maintains the current time even when there is no AC supplied to the system.
4.2.1.1 System Clock Synchronization
The BIOS must send the Set SEL Time command with the current system time to the BMC during system Power-on Self Test (POST). Synchronization during very early POST is preferred, so that any
SEL entries recorded during system boot can be accurately time stamped. Additionally, during sleep state transitions other than S0 the BIOS will synchronize the time.
If the time is modified through an OS interface, then the BMC’s time is not synchronized until the next system reboot.
Revision 1.2 Intel order number G34153-003 51
Platform Management Overview
4.2.2 System Event Log (SEL)
The BMC implements the system event log as specified in the Intelligent Platform Management Interface
Specification, Version 2.0. The SEL is accessible regardless of the system power state through the
BMC's in-band and out-of-band interfaces.
The BMC allocates 95231 bytes (approximately 93 KB) of non-volatile storage space to store system events. The SEL timestamps may not be in order. Up to 3,639 SEL records can be stored at a time. Any comma nd that results in an overflow of the SEL beyond the allocated space is rejected with an “Out of
Space” IPMI completion code (C4h).
4.2.3 Sensor Data Record (SDR) Repository
The BMC implements the sensor data record (SDR) repository as specified in the Intelligent Platform
Management Interface Specification, Version 2.0.
The SDR is accessible through the BMC’s in-band and out-of-band interfaces regardless of the system power state The BMC allocates 65,519 bytes of nonvolatile storage space for the SDR.
4.2.4 Field Replaceable Unit (FRU) Inventory Device
The BMC implements the interface for logical FRU inventory devices as specified in the Intelligent
Platform Management Interface Specification, Version 2.0. This functionality provides commands used for accessing and managing the FRU inventory information. These commands can be delivered through all interfaces.
The BMC provides FRU device command access to its own FRU device and to the FRU devices throughout the server. The FRU device ID mapping is defined in the Platform Specific Information. The
BMC controls the mapping of the FRU device ID to the physical device.
4.2.5 BMC Beep Codes
The BMC may generate beep codes upon detection of failure conditions. Beep codes are sounded each time the problem is discovered (for example, on each power-up attempt), but are not sounded continuously. Common supported codes are listed in below Table
Additional platform-specific beep codes can be found in the appropriate Platform Specific
Information. Each digit in the code is represented by a sequence of beeps whose count is equal to the digit.
Table 12. BMC Beep Codes
Code Reason for Beep
1-5-2-1 No CPUs installed or first CPU socket is empty.
1-5-2-4 MSID Mismatch.
1-5-4-2 Power fault: DC power is unexpectedly lost (power good dropout).
1-5-4-4 Power control fault (power good assertion timeout).
1-5-1-2 VR Watchdog Timer sensor assertion
Associated Sensors
CPU Missing Sensor
MSID Mismatch Sensor.
Power unit
– power unit failure offset.
Power unit
– soft power control failure offset.
VR Watchdog Timer
52 Intel order number G34153-003 Revision 1.2
Platform Management Overview
4.2.6
Code Reason for Beep
1-5-1-4 The system does not power on or unexpectedly powers off and a power supply unit (PSU) is present that is an incompatible model with one or more other PSUs in the system
Diagnostic Interrupt (NMI) Button
Associated Sensors
PS Status
The BMC generates an NMI pulse under certain conditions. The BMC-generated NMI pulse duration is at least 30 ms. Once an NMI has been generated by the BMC, the BMC does not generate another NMI until the system has been reset or powered down.
The following actions cause the BMC to generate an NMI pulse:
1. Receiving a Chassis Control command to pulse the diagnostic interrupt. This command does not cause an event to be logged in the SEL.
2. Watchdog timer pre-timeout expiration with NMI/diagnostic interrupt pre-timeout action enabled.
The following table shows the behavior regarding NMI signal generation and event logging by the
BMC.
Table 13. NMI Signal Generation and Event Logging
Causal Event NMI
Signal Generation Front Panel Diag Interrupt Sensor Event Logging
Support
Chassis Control command (pulse diagnostic interrupt)
Front panel diagnostic interrupt button pressed
Watchdog Timer pre-timeout expiration with
NMI/diagnostic interrupt action
X
X
X
–
X
X
4.2.7 BMC Watchdog
The BMC FW is increasingly called upon to perform system functions that are time-critical in that failure to provide these functions in a timely manner can result in system or component damage. Intel
®
S1400/S1600/S2400/S2600 Server Platforms introduce a BMC watchdog feature to provide a safe-guard against this scenario by providing an automatic recovery mechanism. It also can provide automatic recovery of functionality that has failed due to a fatal FW defect triggered by a rare sequence of events or a BMC hang due to some type of HW glitch (for example, power).
This feature is comprised of a set of capabilities whose purpose is to detect misbehaving subsections of
BMC firmware, the BMC CPU itself, or HW subsystems of the BMC component, and to take appropriate action to restore proper operation. The action taken is dependent on the nature of the detected failure and may result in a restart of the BMC CPU, one or more BMC HW subsystems, or a restart of malfunctioning
FW subsystems.
The BMC watchdog feature will only allow up to three resets of the BMC CPU (such as HW reset) or entire FW stack (such as a SW reset) before giving up and remaining in the uBOOT code. This count is cleared upon cycling of power to the BMC or upon continuous operation of the BMC without a watchdog-generated reset occurring for a period of > 30 minutes. The BMC
FW logs a SEL event indicating that a watchdog-generated BMC reset (either soft or hard reset) has occurred. This event may be logged after the actual reset has occurred. Refer sensor
Revision 1.2 Intel order number G34153-003 53
Platform Management Overview section for details for the related sensor definition. The BMC will also indicate a degraded system status on the Front Panel Status LED after an BMC HW reset or FW stack reset. This state (which follows the state of the associated sensor) will be cleared upon system reset or (AC or DC) power cycle.
Note: A reset of the BMC may result in the following system degradations that will require a system reset or power cycle to correct:
1. Timeout value for the rotation period can be set using this parameter; potentially incorrect
ACPI Power State reported by the BMC.
2. Reversion of temporary test modes for the BMC (for example, as set through Set SM Signal command) back to normal operational modes.
3. FP status LED and DIMM fault LEDs may not reflect BIOS detected errors.
4.3 Sensor Monitoring
4.3.1 Overview
The BMC monitors system hardware and reports system health. The information gathered from physical sensors is translated into IPMI sensors as part of the “IPMI Sensor Model”. The BMC also reports various system state changes by maintaining virtual sensors that are not specifically tied to physical hardware.
This section describes the BMC sensors as well as describing how specific sensor types are modeled.
Unless otherwise specified, the term “sensor” refers to the IPMI sensor-model definition of a sensor.
4.3.2 Core Sensor List for EPSD Platforms Based on Intel
®
Processor E5
4600/2600/2400/1600/1400 Product Families
Specific server boards may only implement a sub-set of sensors and/or may include additional sensors.
The system-specific details of supported sensors and events are described in the Appendix of this document. The actual sensor name associated with a sensor number may vary between server boards or systems.
Sensor Type Codes
Sensor table given below lists the sensor identification numbers and information regarding the sensor type, name, supported thresholds, assertion and de-assertion information, and a brief description of the sensor purpose. Refer to the Intelligent Platform Management Interface Specification, Version 2.0 for sensor and event/reading-type table information.
Sensor Type
The sensor type references the values in the Sensor Type Codes table in the Intelligent Platform
Management Interface Specification Second Generation v2.0. It provides a context to interpret the sensor.
Event/Reading Type
The event/reading type references values from the Event/Reading Type Code Ranges and the
Generic Event/Reading Type Code tables in the Intelligent Platform Management Interface
Specification Second Generation v2.0. Digital sensors are specific type of discrete sensors that only have two states.
Event Thresholds/Triggers
The following event thresholds are supported for threshold type sensors:
- [u,l][nr,c,nc] upper non-recoverable, upper critical, upper non-critical, lower non-recoverable, lower critical, lower non-critical uc, lc upper critical, lower critical
Event triggers are supported event-generating offsets for discrete type sensors. The offsets can be found in the Generic Event/Reading Type Code or Sensor Type Code tables in the Intelligent
54 Intel order number G34153-003 Revision 1.2
Platform Management Overview
Platform Management Interface Specification Second Generation, Version 2.0, depending on whether the sensor event/reading type is generic or a sensor-specific response.
Assertion/Deassertion
Assertion and de-assertion indicators reveal the type of events this sensor generates:
-
As: Assertion
- De: De-assertion
Readable Value/Offsets
-
Readable value indicates the type of value returned for threshold and other nondiscrete type sensors.
- Readable offsets indicate the offsets for discrete sensors that are readable by means of the Get Sensor Reading command. Unless otherwise indicated, event triggers are readable. Readable offsets consist of the reading type offsets that do not generate events.
Event Data
Event data is the data that is included in an event message generated by the associated sensor.
For threshold-based sensors, these abbreviations are used:
-
R: Reading value
-
T: Threshold value
Rearm Sensors
The rearm is a request for the event status for a sensor to be rechecked and updated upon a transition between good and bad states. Rearming the sensors can be done manually or automatically. This column indicates the type supported by the sensor. The following abbreviations are used in the comment column to describe a sensor:
-
A: Auto-rearm
- M: Manual rearm
-
I: Rearm by init agent
Default Hysteresis
The hysteresis setting applies to all thresholds of the sensor. This column provides the count of hysteresis for the sensor, which can be 1 or 2 (positive or negative hysteresis).
Criticality
Criticality is a classification of the severity and nature of the condition. It also controls the behavior of the front panel status LED.
Standby
Some sensors operate on standby power. These sensors may be accessed and/or generate events when the main (system) power is off, but AC power is present.
4.3.3 BMC System Management Health Monitoring
The BMC tracks the health of each of its IPMI sensors and report failures by providing a “BMC FW
Health” sensor of the IPMI 2.0 sensor type Management Subsystem Health with support for the Sensor
Failure offset. Only assertions should be logged into the SEL for the Sensor Failure offset. The sensor number of the failed sensor is provided in event data byte 2, as per the IPMI 2.0 Specification. The BMC
Firmware Health sensor asserts for any sensor when 10 consecutive sensor errors are read. These are not standard sensor events (that is, threshold crossings or discrete assertions). These are BMC Hardware
Access Layer (HAL) errors like I2C NAKs or internal errors while attempting to read a register. If a successful sensor read is completed, the counter resets to zero.
IPMI Sensor Characteristics
Revision 1.2 Intel order number G34153-003 55
Platform Management Overview
1. Event reading type code: 6Fh (Sensor specific)
2. Sensor type code: 28h (Management Subsystem Health)
3. Rearm type: Auto
If this sensor is implemented, then the following sensor-specific offsets are supported.
Table 14. Supported BMC FW Health Sensor Offsets
Offset
04h
Description
Sensor failure
Event Logging
Assertion and deassertion
4.3.4 Processor Sensors
The BMC provides IPMI sensors for processors and associated components, such as voltage regulators and fans. The sensors are implemented on a per-processor basis.
Table 15. Processor Sensors
Sensor Name
Processor Status
Digital Thermal Sensor
Processor VRD Over-Temperature
Indication
Processor Voltage
Per-Processor
Socket
Yes
Yes
Yes
Yes
Processor Thermal Control (Prochot) Yes
Description
Processor presence and fault state
Relative temperature reading by means of PECI
Discrete sensor that indicates a processor VRD has crossed an upper operating temperature threshold
Threshold sensor that indicates a processor power-good state
Percentage of time a processor is throttling due to thermal conditions
4.3.4.1 Processor Status Sensors
The BMC provides an IPMI sensor of type processor for monitoring status information for each processor slot. If an event state (sensor offset) has been asserted, it remains asserted until one of the following happens:
1. A Rearm Sensor Events command is executed for the processor status sensor.
2. AC or DC power cycle, system reset, or system boot occurs.
The BMC provides system status indication to the front panel LEDs for processor fault conditions shown
CPU Presence status is not saved across AC power cycles and therefore will not generate a de-assertion after cycling AC power.
Table 16. Processor Status Sensor Implementation
3
4
5
Offset
0
1
2
Internal error (IERR)
Thermal trip
Processor Status Detected By
Not Supported
BMC
FRB1/BIST failure
FRB2/Hang in POST failure
Not Supported
BIOS
1
FRB3/Processor startup/initialization failure (CPU fails to start) Not Supported
Configuration error (for DMI) BIOS
1
56 Intel order number G34153-003 Revision 1.2
Platform Management Overview
4.3.4.1.1
Offset
6
7
8
Processor presence detected
Processor disabled
Processor Status
SM BIOS uncorrectable CPU-complex error
9 Terminator presence detected
Note: Fault is not reflected in the processor status sensor.
Processor Presence
Detected By
Not Supported
BMC
Not Supported
Not Supported
Upon BMC initialization, which occurs when AC power is applied or the BMC is reset, the processor presence offset is initialized to the deasserted state and then the BMC checks to see if the processor is present and sets the presence offset accordingly.
This state is updated at each DC power-on and at system resets. The net effect of this is that there should be one event logged at BMC startup for processor presence for each installed processor, assuming the SDR is configured to generate the event. No additional events for processor presence are expected unless the sensor is manually re-armed using an IPMI command or a processor is removed or inserted. Note that removal and insertion should only occur when AC power is removed from the system so it is not expected that a SEL entry will be seen for this specific occurrence.
4.3.4.2 Processor Population Fault (CPU Missing) Sensor
The BMC supports a Processor Population Fault sensor for monitoring for the condition in which processor slots are not populated as required by the platform HW to allow power-on of the system.
At BMC startup, the BMC will check for the fault condition and set the sensor state accordingly.
The BMC also checks for this fault condition at each attempt to DC power-on the system. At each DC power-on attempt, a beep code is generated if this fault is detected. Please refer Table
9 (BMC Beep Codes) for beep code details.
The following steps are used to correct the fault condition and clear the sensor state:
1. AC power down the server.
2. Install the missing processor into the correct slot.
3. AC power on the server.
Refer to the applicable platform BMC EPS as to the details of what population rules must be followed.
4.3.4.3 ERR2 Timeout Monitoring
The BMC supports an ERR2 Timeout Sensor (1 per CPU) that asserts if a CPU’s ERR2 signal has been asserted for longer than a fixed time period (> 90 seconds). ERR[2] is a processor signal that indicates when the IIO (Integrated IO module in the processor) has a fatal error which could not be communicated to the core to trigger SMI. ERR[2] events are fatal error conditions, where the BIOS and OS will attempt to gracefully handle error, but may not be always do so reliably. A continuously asserted ERR2 signal is an indication that the BIOS cannot service the condition that caused the error. This is usually because that condition prevents the BIOS from running.
When an ERR2 timeout occurs, the BMC asserts/deasserts the ERR2 Timeout Sensor, and logs a SEL event for that sensor. The default behavior for BMC core firmware is to initiate a system reset upon detection of an ERR2 timeout. The BIOS setup utility provides an option to disable or enable system reset by the BMC for detection of this condition.
IPMI Sensor Characteristics
Revision 1.2 Intel order number G34153-003 57
Platform Management Overview
1. Event reading type code: 03h (Generic
– digital discrete)
2. Sensor type code: 07h (Processor)
3. Rearm type: Auto
Table 17. Supported ERR2 Timeout Sensor Offsets
Offset
01h
Description
State asserted
Event Logging
Assertion and deassertion
4.3.4.4 CATERR Sensor and Market Segment ID (MSID) Mismatch
The BMC supports a CATERR sensor for monitoring the system CATERR signal.
The CATERR signal is defined as having 3 states; high (no event), pulsed low (possibly fatal may be able to recover), and low (fatal). All processors in a system have their CATERR pins tied together. The pin is used as a communication path to signal a catastrophic system event to all CPUs. The BMC has direct access to this aggregate CATERR signal.
The BMC only monitors for the “CATERR held low” condition. A pulsed low condition is ignored by the
BMC.
If a CATERR-low condition is detected, the BMC logs an error message to the SEL against the
CATERR sensor and then queries each CPU to determine if it was due to an MSID mismatch condition. An MSID mismatch occurs if a processor is installed into a system board that has incompatible power capabilities. The MSID mismatch condition is indicated in a processor machine check MSR. If PECI is nonfunctional (it isn’t guaranteed in this situation), then MSID mismatch can’t be detected in that case.
If the CATERR is due to an MSID mismatch, then the BMC will log an additional SEL log against the MSID Mismatch sensor, light the CPU fault LED, emit a beep code, and let the system hang. Please refer Table 9 (BMC Beep Codes) for beep code details. If no MSID mismatch is detected, then the default action after logging the SEL entry is to reset the system.
The BIOS setup utility provides an option to disable or enable system reset by the BMC for detection of this condition.
4.3.4.5 CATERR Sensor
The BMC supports a CATERR sensor for monitoring the system CATERR signal.
The sensor is rearmed on power-on (AC or DC power on transitions). It is not rearmed on system resets in order to avoid multiple SEL events that could occur due to a potential reset loop if the CATERR keeps recurring, which would be the case if the CATERR was due to an MSID mismatch condition.
On EPSD boards, the CATERR signal from each CPU are tied together and routed to the BMC as one signal. When the BMC detects that this aggregate CATERR signal has asserted, it can then go through
PECI to query each CPU to determine which one was the source of the error and write an OEM code identifying the CPU slot into an event data byte in the SEL entry. If PECI is nonfunctional (it isn’t guaranteed in this situation), then the OEM code should indicate that the source is unknown.
Event data byte 2 and byte 3 for CATERR sensor SEL events
ED2 - CATERR type.
0: Unknown
1: CATERR
58 Intel order number G34153-003 Revision 1.2
Platform Management Overview
2: CPU Core Error (not supported on EPSD Platforms Based on Intel
®
Xeon
®
Processor E5
4600/2600/2400/1600 Product Families)
3: MSID Mismatch
ED3 - CPU bitmap that causes the system CATERR.
[0]: CPU0
[1]: CPU1
[2]: CPU2
[3]: CPU3
IPMI Sensor Characteristics
1. Event reading type code: 03h (Digital discrete)
2. Sensor type code: 07h (Processor)
3. Rearm type: Manual
The following sensor-specific offsets are supported:
Table 18. Supported CATERR Sensor Offsets
Offset
01h
Description
State asserted
Event Logging
Assertion and deassertion
4.3.4.6 MSID Mismatch Sensor
The BMC supports a MSID Mismatch sensor for monitoring for the fault condition that will occur if there is a power rating incompatibility between a baseboard and an a processor
The sensor is rearmed on power-on (AC or DC power on transitions).
IPMI Sensor Characteristics
1. Event reading type code: 03h (Digital discrete)
2. Sensor type code:
3. Rearm type:
07h (Processor)
Manual
The following sensor-specific offsets are supported:
Offset
Table 19. Support MSID Mismatch Sensor Offsets
Description Event Logging
01h State asserted Assertion and deassertion
4.4 Thermal and Acoustic Management
The Intel
®
Server Board S2600IP and Intel
®
Workstation Board W2600CR offers multiple thermal and acoustic management features to maintain comprehensive thermal protection as well as intelligent fan speed control. The features can be adjusted in BIOS interface with path BIOS > Advanced > System
Acoustic and Performance Configuration.
Revision 1.2 Intel order number G34153-003 59
Platform Management Overview
4.4.1 Set Throttling Mode
Select the most appropriate memory thermal throttling mechanism for memory sub-system from
[Auto], [DCLTT], [SCLTT] and [SOLTT].
[Auto]
– BIOS automatically detect and identify the appropriate thermal throttling mechanism based on DIMM type, airflow input, DIMM sensor availability.
[DCLTT]
– Dynamic Closed Loop Thermal Throttling: for the SOD DIMM with system airflow input
[SCLTT]
– Static Close Loop Thermal Throttling: for the SOD DIMM without system airflow input
[SOLTT]
– Static Open Loop Thermal Throttling: for the DIMMs without sensor on dimm (SOD)
The default setting is [Auto].
4.4.2 Altitude
Select the proper altitude that the system is distributed from [300m or less], [301m-900m], [901m-1500m],
[Above 1500m] options. Lower altitude selection can lead to potential thermal risk. And higher altitude selection provides better cooling but with undesired acoustic and fan power consumption. If the altitude is known, higher altitude is recommended in order to provide sufficient cooling. The default setting is [301m
– 900m].
4.4.3 Set Fan Profile
[Performance] and [Acoustic] fan profiles are available to select. The Acoustic mode offers best acoustic experience and appropriate cooling capability covering mainstream and majority of the add-in cards.
Performance mode is designed to provide sufficient cooling capability covering all kinds of add-in cards on the market. The default setting is [Performance]
4.4.4 Fan PWM Offset
This feature is reserved for manual adjustment to the minimum fan speed curves. The valid range is from [0 to 100] which stands for 0% to 100% PWM adding to the minimum fan speed.
This feature is valid when Quiet Fan Idle Mode is at Enabled state. The default setting is [0].
4.4.5 Quiet Fan Idle Mode
This feature can be [Enabled] or [Disabled]. If enabled, the fan will either stopped or shift to a lower speed when the aggregate sensor temperatures are satisfied indicating the system is at ideal thermal/light loading conditions. When the aggregate sensor temperatures not satisfied, the fan will shift back to normal control curves. If disabled, the fan will never stopped or shift into lower fan speed whatever the aggregate sensor temperatures are satisfied or not. The default setting is [Disabled]
Note:
1. The above features may or may not be in effective depends on the actual thermal characters of a specific system.
2. Refer to System TPS for the board in Intel chassis thermal and acoustic management
3. Refer to Fan Control Whitepaper for the board in third party chassis fan speed control customization.
60 Intel order number G34153-003 Revision 1.2
Platform Management Overview
4.4.6 Thermal Sensor Input for Fan Speed Control
The BMC uses various IPMI sensors as inputs to FSC. Some of the sensors are actual physical sensor and some are
“virtual” sensors derived from calculation.
The following IPMI thermal sensors are used as input to the fan speed control:
Front Panel Temperature Sensor
1
Baseboard Temperature Sensor
2
CPU Margin Sensors
3,5,6
DIMM Thermal Margin Sensors
3,5
Exit Air Temperature Sensor
1, 4, 8
PCH Temperature Sensor
4,6
On-board Ethernet Controller Temperature Sensors
4, 6
Add-In Intel SAS/IO Module Temperature Sensors
4, 6
PSU Thermal Sensor
4, 9
CPU VR Temperature Sensors
4, 7
DIMM VR Temperature Sensors
4, 7
iBMC Temperature Sensor
4, 7
Global Aggregate Thermal Margin Sensors
3, 8
Note:
1. For fan speed control in Intel chassis
2. For fan speed control in 3rd party chassis
3. Temperature margin from throttling threshold
4. Absolute temperature
5. PECI value
6. On-die sensor
7. On-board sensor
8. Virtual sensor
9. Available only when PSU has PMBus*
A simplified model is shown as below which gives a high level concept of the fan speed control structure.
Revision 1.2
Figure 25. High-level Fan Speed Control Process
Intel order number G34153-003 61
Platform Management Overview
4.4.7 Power Supply Status\Health Sensors
The BMC supports one Power Supply Status sensor for each system power supply module. In order to track problems in which the PSU firmware is not operating to full capacity, an additional case (degraded condition if the PSU firmware is not operating to full capacity) is added to the existing Power Supply Status sensor offset definitions. This is handled by assertion of the
“configuration error” offset of the PSU status sensor. These sensors are only supported for systems that use PMBus*-compliant power supplies.
IPMI Sensor Characteristics
1. Event reading type code: 6Fh (Sensor Specific)
2. Event sensor type code: 08h (Power Supply)
3. Rearm type: Auto
The following sensor-specific offsets are supported.
Table 20. Supported Power Supply Status Sensor Offsets
Offset
00h
01h
Description
Presence detected
– Asserted if power supply module is present. Events are only logged for power supply presence upon changes in the presence state after AC power is applied (no events logged for initial state).
Power supply failure detected
– Asserted if power supply module has failed.
The following codes for failure modes are put into the SEL Event Data 2 byte:
01h - Output voltage fault
02h - Output power fault
03h - Output over-current fault
04h - Over-temperature fault
05h
– Fan fault
The SEL Event Data 3 byte will have the contents of the associated
PMBus* Status register to allow for showing multiple conditions for the event. For example, Data 3 will have the contents of the
VOLTAGE_STATUS register at the time an Output Voltage fault was detected. Refer to the PMBus Specification for details on specific resister contents
Event Logging
Assertion and
Deassertion
Assertion and
Deassertion
62 Intel order number G34153-003 Revision 1.2
Platform Management Overview
Offset
02h
03h
06h
Description
Predictive failure
– Asserted if some condition, such as failing fan, has been detected that is likely to lead to a power supply module failure.
The following codes for warning modes are put into the SEL Event Data 2 byte:
01h - Output voltage warning
02h - Output power warning
03h - Output over-current warning
04h - Over-temperature warning
05h - Fan warning
06h - Under-voltage warning
07h - Input over-current warning
08h - Input over-power warning
The SEL Event Data 3 byte will have the contents of the associated
PMBus* Status register to allow for showing multiple conditions for the event. For example, Data 3 will have the contents of the
VOLTAGE_STATUS register at the time an Output Voltage Warning was detected. Refer to the PMBus Specification for details on specific resister contents.
Power supply AC lost
– Asserted if there is no AC power input to power supply module.
Configuration error
– The following codes for configuration errors are put into the SEL Event Data 2 byte:
01h - The BMC cannot access the PMBus* device on the PSU but its
FRU device is responding.
02h - The PMBUS_REVISION command returns a version number that is not supported (only version 1.1 and 1.2 are supported for platforms covered under this FW EAS).
03h - The PMBus* device does not successfully respond to the
PMBUS_REVISION command.
04h
– The PSU is incompatible with one or more PSUs that are present in the system.
05h
–The PSU FW is operating in a degraded mode (likely due to a failed firmware update).
Event Logging
Assertion and
Deassertion
Assertion and
Deassertion
Assertion and
Deassertion
4.4.8 System Event Sensor
The BMC supports a System Event sensor and logs SEL event for following events.
04h
Table 21. Support System Event Sensor Offsets
Offset
02h
Description
OEM code (Undetermined system HW failure)
PEF action
Event Logging
Assertion and
Deassertion
Assertion only
For offset 2, OEM code will be logged in event data byte 2 to indicate the type of failure. Only one value will be supported at this time, but others may be added in the future. The code for this particular fault will be 0x00 (PECI access failure) and all other values reserved. Upon detection of the CPU PECI fault condition, the offset shall assert. It shall deassert upon system power cycle or system reset. Assertion of offset 02h shall contribute a “fatal” condition to the system status as reflected in the Front Panel system status LED.
Revision 1.2 Intel order number G34153-003 63
Platform Management Overview
4.4.8.1 Update Related SEL Logging
BMC FW will support a single FW Update Status sensor. This sensor is used to generate SEL events related to update of embedded firmware on the platform. This includes updates to the BMC, BIOS, and
ME FW.
IPMI Sensor Characteristics
1. Event reading type code: 70h (OEM defined)
2. Sensor type code: 2Bh (Version Change)
3. Rearm type: Auto
This sensor is an event-only sensor that is not readable. Event generation is only enabled for assertion events. Since this is an event-only sensor it should be defined by a type-3 SDR as defined in the IPMI 2.0 Specification.
Offset
00h
01h
02h
Table 22. Supported Firmware Update Status Sensor Offsets
Description
Update started
Update completed successfully
Update failure
Event
Logging
Contribution to system health
Assertion OK
Assertion OK
Assertion OK
Event Data Bytes
Byte 2: [Bits 7:4] Target of update
0000b = BMC
0001b = BIOS
0010b = ME
0011b = EWS (Embedded Web server)
All other values reserved
[Bits 3:1] Target instance (zero-based)
Byte 3:
[Bits 0:0] Reserved
Reserved
Note: All reserved bits must be set to zero.
4.5 Platform Management Interface
This chapter describes the supported BMC communication interfaces:
1. Host SMS interface by means of low pin count (LPC)/keyboard controller style (KCS) interface
2. Host SMM interface by means of low pin count (LPC)/keyboard controller style (KCS) interface
3. Intelligent Platform Management Bus (IPMB) I2C interface
4. LAN interface using the IPMI-over-LAN protocols
64 Intel order number G34153-003 Revision 1.2
Platform Management Overview
4.5.1 Channel Management
Every messaging interface is assigned an IPMI channel ID by IPMI 2.0. Commands are provided to
configure each channel for privilege levels and access modes. Table 23 shows the standard channel
assignments:
Table 23. Standard Channel Assignments
Channel ID
0
1
2
3
4
5
6
Interface
Primary IPMB
LAN 1
LAN 2
LAN3
1
(Provided by the Intel
®
Dedicated Server Management NIC)
Reserved
USB
Secondary IPMB
No
Yes
Supports
Sessions
Yes
Yes
Yes
No
No
7 SMM
8
– 0Dh
Reserved
0Eh Self
2
0Fh SMS/Receive Message Queue
Notes:
1. Optional hardware supported by the server system.
No
–
–
No
2. Refers to the actual channel used to send the request.
4.5.2 User Model
The BMC supports the IPMI 2.0 user model. 15 user IDs are supported. These 15 users can be assigned to any channel. The following restrictions are placed on user-related operations:
1. User names for User IDs 1 and 2 cannot be changed. These are always “” (Null/blank) and “root” respectively.
2.
User 2 (“root”) always has the administrator privilege level.
3. All user passwords (including passwords for 1 and 2) may be modified.
4. User IDs 3-15 may be used freely, with the condition that user names are unique. Therefore, no other users can be named “” (Null), “root,” or any other existing user name.
4.5.3 LAN Interface
The BMC implements both the IPMI 1.5 and IPMI 2.0 messaging models. These provide out-of-band local area network (LAN) communication between the BMC and the network.
Run-time determination of LAN channel capabilities can be determined by both standard IPMI defined mechanisms.
Revision 1.2 Intel order number G34153-003 65
Platform Management Overview
4.5.3.1 IPMI 1.5 Messaging
The communication protocol packet format consists of IPMI requests and responses encapsulated in an
IPMI session wrapper for authentication, and wrapped in an RMCP packet, which is wrapped in an
IP/UDP packet. Although authentication is provided, no encryption is provided, so administrating some settings, such as user passwords, through this interface is not advised. Session establishment commands are IPMI commands that do not require authentication or an associated session.
The BMC supports the following authentication types over the LAN interface.
1. None (no authentication)
2. Straight password/key
3. MD5
4.5.3.2 IPMI 2.0 Messaging
IPMI 2.0 messaging is built over RMCP+ and has a different session establishment protocol. The session commands are defined by RMCP+ and implemented at the RMCP+ level, not IPMI commands.
Authentication is implemented at the RMCP+ level. RMCP+ provides link payload encryption, so it is possible to communicate private/sensitive data (confidentiality).
The BMC supports the cipher suites identified in Table 24.
Table 24. Supported RMCP+ Cipher Suites
ID Authentication Algorithm
0
1
RAKP-none
1
2
RAKP-HMAC-SHA1
RAKP-HMAC-SHA1
Integrity Algorithm(s)
None
None
HMAC-SHA1-96
Confidentiality Algorithm(s)
None
None
None
3
6
7
8
RAKP-HMAC-SHA1
RAKP-HMAC-MD5
RAKP-HMAC-MD5
RAKP-HMAC-MD5
11 RAKP-HMAC-MD5
HMAC-SHA1-96
None
HMAC-MD5-128
HMAC-MD5-128
MD5-128
AES-CBC-128
None
None
AES-CBC-128
None
12 RAKP-HMAC-MD5 MD5-128 AES-CBC-128
Note: Cipher suite 0 defaults to callback privilege for security purposes. This may be changed by any administrator.
For user authentication, the BMC can be configured with ‘null’ user names, whereby password/key lookup is done based on ‘privilege level only’, or with non-null user names, where the key lookup for the session is determined by user name.
IPMI 2.0 messaging introduces payload types and payload IDs to allow data types other than IPMI commands to be transferred. IPMI 2.0 serial-over-LAN is implemented as a payload type.
Table 25. Supported RMCP+ Payload Types
Payload Type
00h
01h
02h
10h
– 15h
Feature
IPMI message N/A
IANA
Serial-over-LAN N/A
OEM explicit Intel (343)
Session setup N/A
66 Intel order number G34153-003 Revision 1.2
Platform Management Overview
4.5.3.3 RMCP/ASF Messaging
The BMC supports RMCP ping discovery in which the BMC responds with a pong message to an
RMCP/ASF ping request. This is implemented per the Intelligent Platform Management Interface
Specification Second Generation v2.0.
4.5.3.4 BMC LAN Channels
The BMC supports three RMII/RGMII ports that can be used for communicating with Ethernet devices.
Two ports are used for communication with the on-board NICs and one is used for communication with an
Ethernet PHY located on an optional add-in card (or equivalent on-board circuitry).
4.5.3.4.1 Baseboard NICs
The specific Ethernet controller (NIC) used on a server is platform-specific but all baseboard device options provide support for an NC-SI manageability interface. This provides a sideband high-speed connection for manageability traffic to the BMC while still allowing for a simultaneous host access to the
OS if desired.
The Network Controller Sideband Interface (NC-SI) is a DMTF industry standard protocol for the side band management LAN interface. This protocol provides a fast multi-drop interface for management traffic.
The baseboard NIC(s) are connected to a single BMC RMII/RGMII port that is configured for RMII operation. The NC-SI protocol is used for this connection and provides a 100 Mb/s full-duplex multi-drop interface which allows multiple NICs to be connected to the BMC. The physical layer is based upon RMII, however RMII is a point-to-point bus whereas NC-SI allows 1 master and up to 4 slaves. The logical layer
(configuration commands) is incompatible with RMII.
Multi-port baseboard NICs on some products will provide support for a dedicated management channel than can be configured to be hidden from the host and only used by the BMC. This mode of operation is configured by a BIOS setup option.
4.5.3.4.2 Dedicated Management Channel
An additional LAN channel dedicated to BMC usage and not available to host SW is supported by an optional add-in card. There is only a PHY device present on the add-in card. The BMC has a builtin MAC module that uses the RGMII interface to link with the card’s PHY. Therefore, for this dedicated management interface, the PHY and MAC are located in different devices.
The PHY on the card connects to the BMC’s other RMII/RGMII interface (that is, the one that is not connected to the baseboard NICs). This BMC port is configured for RGMII usage.
In addition to the use of an add-in card for a dedicated management channel, on systems that support multiple Ethernet ports on the baseboard, the system BIOS provides a setup option to allow one of these baseboard ports to be dedicated to the BMC for manageability purposes.
When this is enabled, that port is hidden from the OS.
4.5.3.4.3 Concurrent Server Management Use of Multiple Ethernet Controllers
Provided the HW supports a management link between the BMC and a NIC port, the BMC FW supports concurrent OOB LAN management sessions for the following combination:
Two on-board NIC ports
One on-board NIC and the optional dedicated add-in management NIC.
Two on-board NICs and optional dedicated add-in management NIC.
Revision 1.2 Intel order number G34153-003 67
Platform Management Overview
All NIC ports must be on different subnets for the above concurrent usage models.
MAC addresses are assigned for management NICs from a pool of up to 3 MAC addresses allocated specifically for manageability. The total number of MAC addresses in the pool is dependent on the product HW constraints (for example,a board with 2 NIC ports available for manageability would have a
MAC allocation pool of 2 addresses).For these channels, support can be enabled for IPMI-over-LAN and
DHCP.
For security reasons, embedded LAN channels have the following default settings:
IP Address: Static
All users disabled
IPMI-enabled network interfaces may not be placed on the same subnet. This includes the Intel
®
Dedicated Server Management NIC and either of the BMC’s embedded network interfaces.
Host-BMC communication over the same physical LAN connection
– also known as “loopback” – is not supported. This includes “ping” operations.
On baseboards with more than two onboard NIC ports, only the first two ports can be used as BMC LAN channels. The remaining ports have no BMC connectivity.
Maximum bandwidth supported by BMC LAN channels are as follows:
BMC LAN1 (Baseboard NIC port) ----- 100M (10M in DC off state)
BMC LAN 2 (Baseboard NIC port) ----- 100M (10M in DC off state)
BMC LAN 3 (Dedicated NIC) ----- 1000M
4.5.3.5 Dedicated Management NIC MAC Address
For EPSD Platforms Based on Intel
®
Xeon
®
Processor E5 4600/2600/2400/1600/1400 Product Families each server board has either five or seven MAC addresses assigned to it at the Intel factory. The printed
MAC address is assigned to NIC1 on the server board.
If the platform has two NIC built into the main board then there will be five MAC addresses assigned as follows:
NIC 1 MAC address (for OS usage)
NIC 2 MAC address = NIC 1 MAC address + 1 (for OS usage)
BMC LAN channel 1 MAC address = NIC1 MAC address + 2
BMC LAN channel 2 MAC address = NIC1 MAC address + 3
BMC LAN channel 3 (RMM) MAC address = NIC1 MAC address + 4
If the platform has four NIC built into the main board then there will be seven MAC addresses assigned as follows:
NIC 1 MAC address (for OS usage)
NIC 2 MAC address = NIC 1 MAC address + 1 (for OS usage)
NIC 3 MAC address = NIC 1 MAC address + 2 (for OS usage)
NIC 4 MAC address = NIC 1 MAC address + 3 (for OS usage)
BMC LAN channel 1 MAC address = NIC1 MAC address + 4
BMC LAN channel 2 MAC address = NIC1 MAC address + 5
BMC LAN channel 3 (RMM) MAC address = NIC1 MAC address + 6.
68 Intel order number G34153-003 Revision 1.2
Platform Management Overview
4.5.3.6 IPV6 Support
In addition to IPv4, Intel
®
S1400/S1600/S2400/S2600 Server Platforms support IPv6 for manageability channels. Configuration of IPv6 is provided by extensions to the IPMI Set and Get LAN Configuration
Parameters commands as well as through a Web Console IPv6 configuration web page.
The BMC supports IPv4 and IPv6 simultaneously so they are both configured separately and completely independently. For example, IPv4 can be DHCP configured while IPv6 is statically configured or vice versa.
4.5.3.6.1 LAN Failover
The BMC FW provides a LAN failover capability such that the failure of the system HW associated with one LAN link will result in traffic being rerouted to an alternate link. This functionality is configurable by IPMI methods as well as by the BMC’s Embedded UI, allowing for user to specify the physical LAN links constitute the redundant network paths or physical
LAN links constitute different network paths. BMC will support only a all or nothin g” approach – that is, all interfaces bonded together, or none are bonded together.
The LAN Failover feature applies only to BMC LAN traffic. It bonds all available Ethernet devices but only one is active at a time. When enabled, If the active connection’s leash is lost, one of the secondary connections is automatically configured so that it has the same IP address
(the next active LAN link will be chosen randomly from the pool of backup LAN links with link status as “UP”). Traffic immediately resumes on the new active connection.
The LAN Failover enable/disable command may be sent at any time. After it has been enabled, standard IPMI commands for setting channel configuration that specify a LAN channel other than the first will return an error code.
Standard IPMI commands for getting channel configuration will return the cached settings for the inactive channels.
4.5.3.7 BMC IP Address Configuration
Enabling the BMC’s network interfaces requires using the Set LAN Configuration Parameter command to configure LAN configuration parameter 4, IP Address Source.
4.5.3.8 DHCP BMC Hostname
The BMC allows setting a DHCP Hostname. DHCP Hostname can be set regardless of the IP Address source configured on the BMC. But this parameter is only used if the IP Address source is set to DHCP.
4.5.3.9 Address Resolution Protocol (ARP)
The BMC can receive and respond to ARP requests on BMC NICs. Gratuitous ARPs are supported, and disabled by default.
4.5.3.10 Virtual Local Area Network (VLAN)
The BMC supports VLAN as defined by IPMI 2.0 specifications. VLAN is supported internally by the BMC, not through switches. VLAN provides a way of grouping a set of systems together so that they form a logical network. This feature can be used to set up a management VLAN where only devices which are members of the VLAN will receive packets related to management and members of the VLAN will be isolated from any other network traffic. Please note that VLAN does not change the behavior of the host network setting, it only affects the BMC LAN communication.
Revision 1.2 Intel order number G34153-003 69
Platform Management Overview
LAN configuration options are now supported (by means of the Set LAN Config Parameters command, parameters 20 and 21) that allow support for 802.1Q VLAN (Layer 2). This allows VLAN headers/packets to be used for IPMI LAN sessions. VLAN ID’s are entered and enabled by means of parameter 20 of the
Set LAN Config Parameters IPMI command. When a VLAN ID is configured and enabled, the BMC only accepts packets with that VLAN tag/ID. Conversely, all BMC generated LAN packets on the channel include the given VLAN tag/ID. Valid VLAN ID
’s are 1 through 4094, VLAN ID’s of 0 and 4095 are reserved, per the 802.1Q VLAN specification. Only one VLAN can be enabled at any point in time on a
LAN channel. If an existing VLAN is enabled, it must first be disabled prior to configuring a new VLAN on the same LAN channel.
Parameter 21 (VLAN Priority) of the Set LAN Config Parameters IPMI command is now implemented and a range from 0-7 will be allowed for VLAN Priorities. Please note that bits 3 and 4 of Parameter 21 are considered Reserved bits.
Parameter 25 (VLAN Destination Address) of the Set LAN Config Parameters IPMI command is not supported and returns a completion code of 0x80 (parameter not supported) for any read/write of parameter 25.
If the BMC IP address source is DHCP, then the following behavior is seen:
If the BMC is first configured for DHCP (prior to enabling VLAN), when VLAN is enabled, the BMC performs a discovery on the new VLAN in order to obtain a new BMC IP address.
If the BMC is configured for DHCP (before disabling VLAN), when VLAN is disabled, the
BMC performs a discovery on the LAN in order to obtain a new BMC IP address.
If the BMC IP address source is Static, then the following behavior is seen:
If the BMC is first configured for static (prior to enabling VLAN), when VLAN is enabled, the BMC has the same IP address that was configured before. It is left to the management application to configure a different IP address if that is not suitable for VLAN.
If the BMC is configure for static (prior to disabling VLAN), when VLAN is disabled, the
BMC has the same IP address that was configured before. It is left to the management application to configure a different IP address if that is not suitable for LAN.
4.5.3.11 Secure Shell (SSH)
Secure Shell (SSH) connections are supported for one SMASH-CLP session to the BMC.
4.5.3.12 Serial-over-LAN (SOL 2.0)
The BMC supports IPMI 2.0 SOL.
IPMI 2.0 introduced a standard serial-over-LAN feature. This is implemented as a standard payload type
(01h) over RMCP+.
Three commands are implemented for SOL 2.0 configuration.
1.
“Get SOL 2.0 Configuration Parameters” and “Set SOL 2.0 Configuration Parameters”: These commands are used to get and set the values of the SOL configuration parameters. The parameters are implemented on a per-channel basis.
2.
“Activating SOL”: This command is not accepted by the BMC. It is sent by the BMC when SOL is activated to notify a remote client of the switch to SOL.
3. Activating a SOL session requires an existing IPMI-over-LAN session. If encryption is used, it should be negotiated when the IPMI-over LAN session is established. Intel
®
Server Board S2600IP SOL
70 Intel order number G34153-003 Revision 1.2
Platform Management Overview
2
3
7
8
9
4
5
6
10
11
12 sessions are supported on serial port A (COM1). Intel
®
Workstation Board S2600IP SOL sessions are supported on serial port B (COM2).
4.5.3.13 Platform Event Filter (PEF)
The BMC includes the ability to generate a selectable action, such as a system power-off or reset, when a match occurs to one of a configurable set of events. This capability is called Platform Event Filtering, or
PEF. One of the available PEF actions is to trigger the BMC to send a LAN alert to one or more destinations.
The BMC supports 20 PEF filters. The first twelve entries in the PEF filter table are pre-configured (but may be changed by the user). The remaining entries are left blank, and may be configured by the user.
Event Filter
Number
1
Table 26. Factory Configured PEF Table Entries
Offset Mask Events
Temperature sensor out of range Non-critical, critical and nonrecoverable
Non-critical, critical and nonrecoverable
Non-critical, critical and nonrecoverable
General chassis intrusion
Failure and predictive failure
Uncorrectable ECC
POST error
FRB2
Policy Correction Time
Power down, power cycle, and reset
OEM system boot event
Drive Failure, Predicted Failure
Voltage sensor out of range
Fan failure
Chassis intrusion (security violation)
Power supply failure
BIOS
BIOS: POST code error
Watchdog Timer expiration for FRB2
Node Manager
Watchdog timer
System restart (reboot)
Hot Swap Controller
Additionally, the BMC supports the following PEF actions:
Power off
Power cycle
Reset
OEM action
Alerts
The “Diagnostic interrupt” action is not supported.
4.5.3.14 LAN Alerting
The BMC supports sending embedded LAN alerts, called SNMP PET (Platform Event traps), and SMTP email alerts.
The BMC supports a minimum of four LAN alert destinations.
Revision 1.2 Intel order number G34153-003 71
Platform Management Overview
4.5.3.14.1 SNMP Platform Event Traps (PETs)
This feature enables a target system to send SNMP traps to a designated IP address by means of LAN.
These alerts are formatted per the Intelligent Platform Management Interface Specification Second
Generation v2.0. A MIB file associated with the traps is provided with the BMC firmware to facilitate interpretation of the traps by external software.
The format of the MIB file is covered under RFC 2578.
4.5.3.15 Alert Policy Table
Associated with each PEF entry is an alert policy that determines which IPMI channel the alert is to be sent. There is a maximum of 20 alert policy entries. There are no pre-configured entries in the alert policy table because the destination types and alerts may vary by user. Each entry in the alert policy table contains four bytes for a maximum table size of 80 bytes.
4.5.3.15.1 E-mail Alerting
The Embedded Email Alerting feature allows the user to receive e-mails alerts indicating issues with the server. This allows e-mail alerting in an OS-absent (for example, Pre-OS and OS-Hung) situation. This feature provides support for sending e-mail by means of SMTP, the Simple Mail Transport Protocol as defined in Internet RC 821. The e-mail alert provides a text string that describes a simple description of the event. SMTP alerting is configured using the embedded web server.
4.5.3.16 SM-CLP (SM-CLP Lite)
SMASH refers to Systems Management Architecture for Server Hardware. SMASH is defined by a suite of specifications, managed by the DMTF, that standardize the manageability interfaces for server hardware. CLP refers to Command Line Protocol. SM-CLP is defined by the Server Management Command Line Protocol Specification (SM-CLP) ver1.0, which is part of the SMASH suite of specifications. The specifications and further information on SMASH can be found at the DMTF website ( http://www.dmtf.org/ ).
The BMC provides an embedded “lite” version of SM-CLP that is syntax-compatible but not considered fully compliant with the DMTF standards.
4.5.3.17 Embedded Web Server
BMC Base manageability provides an embedded web server and an OEM-customizable web
GUI which exposes the manageability features of the BMC base feature set. It is supported over all on-board NICs that have management connectivity to the BMC as well as an optional dedicated add-in management NIC. At least two concurrent web sessions from up to two different users is supported. The embedded web user interface shall support the following client web browsers:
Microsoft Internet Explorer 7.0*
Microsoft Internet Explorer 8.0*
Microsoft Internet Explorer 9.0*
Mozilla Firefox 3.0*
Mozilla Firefox 3.5*
Mozilla Firefox 3.6*
The embedded web user interface supports strong security (authentication, encryption, and firewall support) since it enables remote server configuration and control. Embedded web server uses ports #80 and #443. The user interface presented by the embedded web user interface
72 Intel order number G34153-003 Revision 1.2
Platform Management Overview shall authenticate the user before allowing a web session to be initiated. Encryption using 128bit SSL is supported. User authentication is based on user id and password.
The GUI presented by the embedded web server authenticates the user before allowing a web session to be initiated. It presents all functions to all users but grays-out those functions that the user does not have privilege to execute. (For example, if a user does not have privilege to power control, then the item shall be displayed in greyout font in that user’s UI display). The web GUI also provides a launch point for some of the advanced features, such as KVM and media redirection. These features are grayed out in the GUI unless the system has been updated to support these advanced features.
Additional features supported by the web GUI includes:
Presents all the Basic features to the users.
Power on/off/reset the server and view current power state.
Displays BIOS, BMC, ME and SDR version information.
Display overall system health.
Configuration of various IPMI over LAN parameters for both IPV4 and IPV6
Configuration of alerting (SNMP and SMTP).
Display system asset information for the product, board, and chassis.
Display of BMC-owned sensors (name, status, current reading, enabled thresholds), including color-code status of sensors.
Provides ability to filter sensors based on sensor type (Voltage, Temperature, Fan and
Power supply related)
Automatic refresh of sensor data with a configurable refresh rate.
On-line help.
Display/clear SEL (display is in easily understandable human readable format).
Supports major industry-standard browsers (Microsoft Internet Explorer* and Mozilla
Firefox*).
The GUI session automatically times-out after a user-configurable inactivity period. By default, this inactivity period is 30 minutes.
Embedded Platform Debug feature - Allow the user to initiate a “diagnostic dump” to a file that can be sent to Intel for debug purposes.
Virtual Front Panel. The Virtual Front Panel provides the same functionality as the local front panel. The displayed LEDs match the current state of the local panel LEDs. The displayed buttons (for example,power button) can be used in the same manner as the local buttons.
Display of ME sensor data. Only sensors that have associated SDRs loaded will be displayed.
Ability to save the SEL to a file.
Ability to force HTTPS connectivity for greater security. This is provided through a configuration option in the UI.
Display of processor and memory information as is available over IPMI over LAN.
Ability to get and set Node Manager (NM) power policies.
Display of power consumed by the server.
Ability to view and configure VLAN settings.
Warn user the reconfiguration of IP address will cause disconnect.
Capability to block logins for a period of time after several consecutive failed login attempts. The lock-out period and the number of failed logins that initiates the lock-out period are configurable by the user.
Server Power Control - Ability to force into Setup on a reset.
Revision 1.2 Intel order number G34153-003 73
Platform Management Overview
4.5.3.18 Virtual Front Panel
Virtual Front Panel is the module present as “Virtual Front Panel” on the left side in the embedded web server when "remote Control" tab is clicked.
Main Purpose of the Virtual Front Panel is to provide the front panel functionality virtually.
Virutal Front Panel (VFP) will mimic the status LED and Power LED status and Chassis ID alone. It is automatically in sync with BMC every 40 seconds.
For any abnormal status LED state, Virtual Front Panel will get the reason behind the abnormal or status LED changes and displayed in VFP side.
As Virtual Front Panel uses the chass is control command for power actions. It won’t log the Front button press event since Logging the front panel press event for Virtual Front
Panel press will mislead the administrator.
For Reset from Virtual Front Panel , the reset will be done by a “Chassis control” command.
For Reset from Virtual Front Panel, the restart cause will be because of “Chassis control” command.
During Power action, Power button/Reset button should not accept the next action until current Power action is complete and the acknowledgment from BMC is received.
EWS will provide a valid message during Power action until it completes the current Power action.
The VFP does not have any effect on whether the front panel is locked by “Set Front Panel
Enables” command.
The chassis ID LED provides a visual indication of a system being serviced. The state of the chassis ID LED is affected by the following actions:
Toggled by turning the chassis ID button on or off.
There is no precedence or lock-out mechanism for the control sources. When a new request arrives, previous requests are terminated. For example, if the chassis ID button is pressed, then the chassis ID LED changes to solid on. If the button is pressed again, then the chassis ID LED turns off.
Note that the chassis ID will turn on because of the original chassis ID button press and will reflect in the Virtual Front Panel after VFP sync with BMC. Virtual Front Panel won’t reflect the chassis LED software blinking by the software command as there is no mechanism to get the chassis ID Led status.
Only Infinite chassis ID ON/OFF by the software command will reflect in EWS during automatic /manual EWS sync up with BMC.
Virtual Front Panel help should available for virtual panel module.
At present, NMI button in VFP is disabled in Intel ®
S1400/S1600/S2400/S2600 Server
Platforms. It can be used in future.
4.5.3.19 Embedded Platform Debug
The Embedded Platform Debug feature supports capturing low-level diagnostic data (applicable MSRs,
PCI config-space registers, and so on). This feature allows a user to export this data into a file that is retrievable from the embedded web GUI, as well as through host and remote IPMI methods, for the purpose of sending to an Intel engineer for an enhanced debugging capability. The files are compressed, encrypted, and password protected. The file is not meant to be viewable by the end user but rather to provide additional debugging capability to an Intel support engineer.
4.5.3.20 Data Center Management Interface (DCMI)
The DCMI Specification is an emerging standard that is targeted to provide a simplified management interface for Internet Portal Data Center (IPDC) customers. It is expected to become a requirement for
74 Intel order number G34153-003 Revision 1.2
Platform Management Overview server platforms which are targeted for IPDCs. DCMI is an IPMI-based standard that builds upon a set of required IPMI standard commands by adding a set of DCMI-specific IPMI OEM commands. Intel
®
S1400/S1600/S2400/S2600 Server Platforms will be implementing the mandatory DCMI features in the
BMC firmware (DCMI 1.1 Errata 1 compliance). Please refer to DCMI 1.1 errata 1 spec for details. Only mandatory commands will be supported. No support for optional DCMI commands. Optional power management and SEL roll over feature is not supported. DCMI Asset tag will be independent of baseboard FRU asset Tag. Please refer table DCMI Group Extension Commands for more details on
DCMI commands.
4.5.3.21 Lightweight Directory Authentication Protocol (LDAP)
The Lightweight Directory Access Protocol (LDAP) is an application protocol supported by the BMC for the purpose of authentication and authorization. The BMC user connects with an LDAP server for login authentication. This is only supported for non-IPMI logins including the embedded web UI and SM-CLP.
IPMI users/passwords and sessions are not supported over LDAP.
LDAP can be configured (IP address of LDAP server, port, and so on) from the BMC’s Embedded Web UI.
LDAP authentication and authorization is supported over the any NIC configured for system management.
The BMC uses a standard Open LDAP implementation for Linux.
Only open LDAP is supported by BMC. Windows and Novel LDAP are not supported.
4.6 BMC Firmware Update
4.6.1 The BMC firmware release Number
The BMC firmware releases are numbered as follows:
AB.CD.XXX
Where:
CD is a two digit number starting with 00 for the first release. This is the number returned in minor ID in
Get Device ID response.
B is major release number (1 for the first major release typically at first production shipment).
A is point release indicator (A=0 means this is a regular official release, A=1 means this is a point release for limited distribution). A hex representation of “AB” is returned in major ID in Get Device ID response.
XXX is the build number for internal tracking. This number is returned in OEM bytes of Get Device ID response.
4.6.2 Boot Recovery Mode
The BMC’s boot block supports firmware transfer updates. The Operational Firmware Transfer mode preserves several files in the PIA Linux file system. Boot Recovery mode cannot preserve the files because it does not understand Linux file systems, and treats it as a large binary data section. This means a Boot Recovery update completely replaces the PIA with the factory default version: an empty
SEL, a default SDR, and default IPMI configuration and user settings.
Boot Recovery mode can successfully complete an update in some situations where the Operational
Firmware Transfer mode will fail. If there is an incompatibility or bug in the operational code causing it to crash or hang, only a Boot Recovery Mode Update works. Another example is if the flash layout of the sections changes across an update. Because the operational Firmware Transfer mode tries to preserve
Revision 1.2 Intel order number G34153-003 75
Platform Management Overview the contents of the PIA section, in this case, it will corrupt the flash where the old PIA section was.
Because the Boot Recovery mode is blindly writing binary data to flash, in this case, it will succeed.
There are two ways to enter Boot Recovery mode:
The Force Firmware Update jumper is asserted when A/C power is applied.
The operational code is corrupt and the boot loader cannot boot.
In the Boot Recovery mode, the BMC only responds to the small set of commands listed above. Only the
KCS SMS interface is supported; USB-based Fast Firmware Update is not supported.
4.6.3 Force Firmware Update Jumper
The Force Firmware Update jumper can be used to put the BMC in Boot Recovery mode for a low-level update. It causes the BMC to abort its normal boot process and stay in the boot loader without executing any Linux code.
The jumper is normally in the de-asserted position. The system must be completely powered off (A/C power removed) before the jumper is moved. After power is re-applied and the firmware update is complete, the system must be powered off again and the jumper must be returned to the de-asserted position before normal operation can begin.
There is no boot
–block-write protection jumper.
4.6.4 Fast Firmware Update over USB
The BMC supports a Fast Firmware Update mode in addition to the standard KCS SMS interface. This is a special protocol that goes over the USB connection between the host and the BMC.
76 Intel order number G34153-003 Revision 1.2
Platform Management Overview
4.7 Advanced Management Feature Support
This section explains the advanced management features supported by the BMC firmware.
4.7.1 Enabling Advanced Management Features
The Advanced management features are to be delivered as part of the BMC FW image. The
BMC’s baseboard SPI flash contains code/data for both the Basic and Advanced features. An optional add-in card Intel
®
RMM4 lite is used as the activation mechanism. When the BMC FW initializes, it attempts to access the Intel
®
RMM4 lite. If the attempt to access Intel
®
RMM4 lite is successful, then the BMC activates the Advanced features.
Advanced manageability features are supported over all NIC ports enabled for server manageability. This includes baseboard NICs as well as the LAN channel provided by the optional Dedicated NIC add-in card.
RMM4 is comprised of two boards
– RMM4 lite and the optional Dedicated Server Management NIC
(DMN). If the optional Dedicated Server Management NIC is not used then the traffic can only go through the onboard Integrated BMC-shared NIC and share network bandwidth with the host system.
Table 27. Enabling Advanced Management Features
Manageability Hardware
Intel
®
Integrated BMC
Benefits
Comprehensive IPMI based base manageability features
Intel
®
Remote Management Module 4
– Lite
Package contains one module
–
1- Key for advance Manageability features.
Intel
®
Remote Management Module 4
Package includes 2 modules
–
1 - key for advance features
2 - Dedicated NIC (1Gbe) for management
No dedicated NIC for management
Enables KVM and media redirection from the onboard
NIC
Dedicated NIC for management traffic. Higher bandwidth connectivity for KVM and media
Redirection with 1Gbe NIC.
4.7.2 Keyboard, Video, Mouse (KVM) Redirection
The BMC firmware supports keyboard, video, and mouse redirection (KVM) over LAN. This feature is available remotely from the embedded web server as a Java applet. This feature is only enabled when the Intel
®
RMM4 lite is present. The client system must have a Java Runtime Environment (JRE) version
6.0 or later to run the KVM or media redirection applets.
The BMC supports an embedded KVM application (Remote Console) that can be launched from the embedded web server from a remote console. USB1.1 or USB 2.0 based mouse and keyboard redirection are supported. It is also possible to use the KVM-redirection (KVM-r) session concurrently with media-redirection (media-r). This feature allows a user to interactively use the keyboard, video, and mouse (KVM) functions of the remote server as if the user were physically at the managed server.
KVM redirection console support the following keyboard layouts: English, Dutch, French,
German, Italian, Russian, and Spanish.
Revision 1.2 Intel order number G34153-003 77
Platform Management Overview
KVM redirection includes a “soft keyboard” function. The “soft keyboard” is used to simulate an entire keyboard that is connected to the remote system.
The “soft keyboard” functionality supports the following layouts: English, Dutch, French, German, Italian, Russian, and Spanish.
The KVM-redirection feature automatically senses video resolution for best possible screen capture and provides high-performance mouse tracking and synchronization. It allows remote viewing and configuration in pre-boot POST and BIOS setup, once BIOS has initialized video.
Other attributes of this feature include:
Encryption of the redirected screen, keyboard, and mouse
Compression of the redirected screen.
Ability to select a mouse configuration based on the OS type.
supports user definable keyboard macros.
KVM redirection feature supports the following resolutions and refresh rates:
640x480 at 60Hz, 72Hz, 75Hz, 85Hz, 100Hz
800x600 at 60Hz, 72Hz, 75Hz, 85Hz
1024x768 at 60Hx, 72Hz, 75Hz, 85Hz
1280x960 at 60Hz
1280x1024 at 60Hz
1600x1200 at 60Hz
1920x1080 (1080p),
1920x1200 (WUXGA)
1650x1080 (WSXGA+)
4.7.2.1 Force-enter BIOS Setup
KVM redirection can present an option to force-enter BIOS Setup. This enables the system to enter F2 setup while booting which is often missed by the time the remote console redirects the video.
4.7.3 Media Redirection
The embedded web server provides a Java applet to enable remote media redirection. This may be used in conjunction with the remote KVM feature, or as a standalone applet.
The media redirection feature is intended to allow system administrators or users to mount a remote IDE or USB CD-ROM, floppy drive, or a USB flash disk as a remote device to the server.
Once mounted, the remote device appears just like a local device to the server, allowing system administrators or users to install software (including operating systems), copy files, update BIOS, and so on, or boot the server from this device.
The following capabilities are supported:
The operation of remotely mounted devices is independent of the local devices on the server. Both remote and local devices are useable in parallel.
Either IDE (CD-ROM, floppy) or USB devices can be mounted as a remote device to the server.
It is possible to boot all supported operating systems from the remotely mounted device and to boot from disk IMAGE (*.IMG) and CD-ROM or DVD-ROM ISO files. See the
Tested/supported Operating System List for more information.
Media redirection supports redirection for both a virtual CD device and a virtual
Floppy/USB device concurrently. The CD device may be either a local CD drive or else an
ISO image file; the Floppy/USB device may be either a local Floppy drive, a local USB device, or else a disk image file.
78 Intel order number G34153-003 Revision 1.2
Platform Management Overview
The media redirection feature supports multiple encryption algorithms, including RC4 and
AES. The actual algorithm that is used is negotiated with the client based on the client’s capabilities.
A remote media session is maintained even when the server is powered-off (in standby mode). No restart of the remote media session is required during a server reset or power on/off. An BMC reset (for example,due to an BMC reset after BMC FW update) will require the session to be re-established
The mounted device is visible to (and useable by) managed system’s OS and BIOS in both pre-boot and post-boot states.
The mounted device shows up in the BIOS boot order and it is possible to change the
BIOS boot order to boot from this remote device.
It is possible to install an operating system on a bare metal server (no OS present) using the remotely mounted device. This may also require the use of KVM-r to configure the OS during install.
USB storage devices will appear as floppy disks over media redirection. This allows for the installation of device drivers during OS installation.
If either a virtual IDE or virtual floppy device is remotely attached during system boot, both the virtual IDE and virtual floppy are presented as bootable devices. It is not possible to present only a single-mounted device type to the system BIOS.
Revision 1.2 Intel order number G34153-003 79
Platform Management Overview
4.8 Intel
®
4.8.1 Overview
Power management deals with requirements to manage processor power consumption and manage power at the platform level to meet critical business needs. Node Manager (NM) is a platform resident technology that enforces power capping and thermal-triggered power capping policies for the platform. These policies are applied by exploiting subsystem knobs (such as processor P and T states) that can be used to control power consumption. NM enables data center power management by exposing an external interface to management software through which platform policies can be specified. It also implements specific data center power management usage models such as power limiting, and thermal monitoring.
The NM feature is implemented by a complementary architecture utilizing the ME, BMC, BIOS, and an
ACPI-compliant OS. The ME provides the NM policy engine and power control/limiting functions (referred to as Node Manager or NM) while the BMC provides the external LAN link by which external management software can interact with the feature. The BIOS provides system power information utilized by the NM algorithms and also exports ACPI Source Language (ASL) code used by OS-Directed Power
Management (OSPM) for negotiating processor P and T state changes for power limiting. PMBus*compliant power supplies provide the capability to monitoring input power consumption, which is necessary to support NM.
4.8.1.1 Hardware Requirements
NM is supported only on platforms that have the NM FW functionality loaded and enabled on the
Management Engine (ME) in the SSB and that have a BMC present to support the external LAN interface to the ME. NM power limiting features requires a means for the ME to monitor input power consumption for the platform. This capability is generally provided by means of PMBus*-compliant power supplies although an alternative model using a simpler SMBus* power monitoring device is possible (there is potential loss in accuracy and responsiveness using non-PMBus* devices). The NM SmaRT/CLST feature does specifically require PMBus*-compliant power supplies as well as additional hardware on the baseboard.
4.8.1.2 Features
NM provides feature support for policy management, monitoring and querying, alerts and notifications, and an external interface protocol. The policy management features implement specific IT goals that can be specified as policy directives for NM. Monitoring and querying features enable tracking of power consumption. Alerts and notifications provide the foundation for automation of power management in the data center management stack. The external interface specifies the protocols that must be supported in this version of NM.
4.8.1.3 ME Firmware Update
On server platforms, the ME FW uses a single operational image with a limited-functionality recovery image. In order to upgrade an operational image, a boot to recovery image must be performed. Unlike last generation platforms, the ME FW does not support an IPMI update mechanism except for the case that the system is configured with a dual-ME (redundant) image.
In order to conserve flash space, which the ME FW shares with BIOS, EPSD systems only support a single ME image. For this case, ME update is only supported by means of BIOS performing a direct update of the flash component. The recovery image only provides the basic functionality that is required to perform the update; therefore other ME FW features are not functional therefore when the update is in progress.
80 Intel order number G34153-003 Revision 1.2
Platform Management Overview
4.8.1.4 SmaRT/CLST
The power supply optimization provided by SmaRT/CLST relies on a platform HW capability as well as
ME FW support. When a PMBus*-compliant power supply detects insufficient input voltage, an overcurrent condition, or an over-temperature condition, it will assert the SMBAlert# signal on the power supply SMBus* (that is, the PMBus*). Through the use of external gates, this results in a momentary assertion of the PROCHOT# and MEMHOT# signals to the processors, thereby throttling the processors and memory. The ME FW also sees the SMBAlert# assertion, queries the power supplies to determine the condition causing the assertion, and applies an algorithm to either release or prolong the throttling, based on the situation.
System power control modes include:
1. SmaRT: Low AC input voltage event; results in a onetime momentary throttle for each event to the maximum throttle state
2. Electrical Protection CLST: High output energy event; results in a throttling hiccup mode with fixed maximum throttle time and a fix throttle release ramp time.
3. Thermal Protection CLST: High power supply thermal event; results in a throttling hiccup mode with fixed maximum throttle time and a fix throttle release ramp time.
When the SMBAlert# signal is asserted, the fans will be gated by HW for a short period (~100ms) to reduce overall power consumption. It is expected that the interruption to the fans will be of short enough duration to avoid false lower threshold crossings for the fan tach sensors; however, this may need to be comprehended by the fan monitoring FW if it does have this side-effect.
ME FW will log an event into the SEL to indicate when the system has been throttled by the
SmaRT/CLST power management feature. This is dependent on ME FW support for this sensor. Please refer ME FW EPS for SEL log details.
4.8.1.4.1 Dependencies on PMBus*-compliant Power Supply Support
The SmaRT/CLST system feature depends on functionality present in the ME NM SKU. This feature requires power supplies that are compliant with the PMBus Specification, Revision 1.2.
4.9 EU Lot 6 Mode
The European Union has set forth a stringent standby power consumption target for systems that are used as primary computing devices in office environments. Owing to the fact in office environments, pedestal servers are being used more and more as workstations and that Value servers could make their way into Home servers, this solution is being requested for some pedestal servers. HW support for EU
Lot6 will only be available for specific EPSD pedestal products.
In order to meet the standby power requirements for EU Lot6 it is necessary to remove power to the BMC, along with other components, when in the S5 state. As this operational mode impacts system feature support, the user has the option of enabling and disabling this mode from the BIOS setup screen utility.
BIOS is responsible for enabling/disabling the system hardware for EU Lot6 operation. It notifies the BMC of the current state with the OEM command Set EULot6 Mode. The BMC saves the state in persistent store and uses it to control special EU Lot6 internal processing during boot, sensor monitoring, and so on as needed.
Wake-on-LAN (WOL) is not supported in EU Lot6 mode.
4.9.1.1 Impact to System Features
The following system features are lost or impacted when EU Lot6 mode is enabled:
Increased boot time (~15-20s) when system is DC power cycled.
Revision 1.2 Intel order number G34153-003 81
System Security o This is due to the fact that both the BMC and BIOS are booting at the same time when the system is powered on (to S0 state). BIOS will need to allow extra time for the BMC to initialize to the point where it can communicate with BIOS.
Note: Even when EU Lot6 is not enabled and the system is AC cycled, this increased boot time is applicable if a user immediately attempts to power the system up (for example, pressing the power button), as in this case both the BMC and BIOS are booting at the same time.
No LAN manageability when on standby, and therefore no remote OOB power on by
BMC.
No support for SOL or KVM for monitoring the entire boot process. o Since BMC is initializing at the same time as BIOS, it will not be possible to have an SOL or KVM session established from the beginning of the system boot.
FP status LED will behave differently (it will be off when on standby) rather than showing fault conditions present at the time the system was powered down.
No beep code due to uninstalled CPU.
No monitoring of any sensors when on standby.
No detection/logging of any ThermTrip faults. o These result as the system is shut down by HW so BMC will not be available to detect that they occurred.
Sensor monitoring after DC power-on will be delayed by the time it takes BMC to initialize its sensor subsystem (~15 to 20s), possibly losing SEL events or failing to provide correct FP LED status LED indication.
Note: This delay occurs on each AC cycle even when EU Lot6 mode is disabled.
Chassis intrusion not detected when in standby
5. System Security
5.1 BIOS Password Protection
The BIOS uses passwords to prevent unauthorized tampering with the server setup. Passwords can restrict entry to the BIOS Setup, restrict use of the Boot Popup menu, and suppress automatic USB device reordering.
82 Intel order number G34153-003 Revision 1.2
System Security
There is also an option to require a Power On password entry in order to boot the system. If the
Power On Password function is enabled in Setup, the BIOS will halt early in POST to request a password before continuing POST.
Both Administrator and User passwords are supported by the BIOS. An Administrator password must be installed in order to set the User password. The maximum length of a password is
14 characters. A password can have alphanumeric (a-z, A-Z, 0-9) characters and it is case sensitive. Certain special characters are also allowed, from the following set:
! @ # $ % ^ & * ( ) - _ + = ?
The Administrator and User passwords must be different from each other. An error message will be displayed if there is an attempt to enter the same password for one as for the other.
The use of “Strong Passwords” is encouraged, but not required. In order to meet the criteria for a “Strong Password”, the password entered must be at least 8 characters in length, and must include at least one each of alphabetic, numeric, and special characters. If a “weak” password is entered, a popup warning message will be displayed, although the weak password will be accepted.
Once set, a password can be cleared by changing it to a null string. This requires the
Administrator password, and must be done through BIOS Setup or other explicit means of changing the passwords. Clearing the Administrator password will also clear the User password.
Alternatively, the passwords can be cleared by using the Password Clear jumper if necessary.
Resetting the BIOS configuration settings to default values (by any method) has no effect on the
Administrator and User passwords.
Entering the User password allows the user to modify only the System Time and System Date in the Setup Main screen. Other setup fields can be modified only if the Administrator password has been entered. If any password is set, a password is required to enter the BIOS setup.
The Administrator has control over all fields in the BIOS setup, including the ability to clear the
User password and the Administrator password.
It is strongly recommended that at least an Administrator Password be set, since not having set a password gives everyone who boots the system the equivalent of Administrative access.
Unless an Administrator password is installed, any User can go into Setup and change BIOS settings at will.
In addition to restricting access to most Setup fields to viewing only when a User password is entered, defining a User password imposes restrictions on booting the system. In order to simply boot in the defined boot order, no password is required. However, the F6 Boot popup prompts for a password, and can only be used with the Administrator password. Also, when a
User password is defined, it suppresses the USB Reordering that occurs, if enabled, when a new USB boot device is attached to the system. A User is restricted from booting in anything other than the Boot Order defined in the Setup by an Administrator.
As a security measure, if a User or Administrator enters an incorrect password three times in a row during the boot sequence, the system is placed into a halt state. A system reset is required to exit out of the halt state. This feature makes it more difficult to guess or break a password.
In addition, on the next successful reboot, the Error Manager displays a Major Error code 0048, which also logs a SEL event to alert the authorized user or administrator that a password
Revision 1.2 Intel order number G34153-003 83
System Security access failure has occurred.
5.2 Trusted Platform Module (TPM) Support
The Trusted Platform Module (TPM) option is a hardware-based security device that addresses the growing concern on boot process integrity and offers better data protection. TPM protects the system start-up process by ensuring it is tamper-free before releasing system control to the operating system. A TPM device provides secured storage to store data, such as security keys and passwords. In addition, a TPM device has encryption and hash functions. The server board implements TPM as per TPM PC Client Specifications revision 1.2 by the Trusted Computing
Group (TCG).
A TPM device is optionally installed onto a high density 14pin connector labeled “TPM” on the server board, and is secured from external software attacks and physical theft. A pre-boot environment, such as the BIOS and operating system loader, uses the TPM to collect and store unique measurements from multiple factors within the boot process to create a system fingerprint. This unique fingerprint remains the same unless the pre-boot environment is tampered with. Therefore, it is used to compare to future measurements to verify the integrity of the boot process.
After the system BIOS completes the measurement of its boot process, it hands off control to the operating system loader and in turn to the operating system. If the operating system is
TPMenabled, it compares the BIOS TPM measurements to those of previous boots to make sure the system was not tampered with before continuing the operating system boot process. Once the operating system is in operation, it optionally uses TPM to provide additional system and data security (for example, Microsoft Vista* supports Bitlocker drive encryption).
5.2.1 TPM security BIOS
The BIOS TPM support conforms to the TPM PC Client Implementation Specification for
Conventional BIOS and to the TPM Interface Specification, and the Microsoft Windows
BitLocker* Requirements. The role of the BIOS for TPM security includes the following:
Measures and stores the boot process in the TPM microcontroller to allow a TPM enabled operating system to verify system boot integrity.
Produces EFI and legacy interfaces to a TPM-enabled operating system for using TPM.
Produces ACPI TPM device and methods to allow a TPM-enabled operating system to send TPM administrative command requests to the BIOS.
Verifies operator physical presence. Confirms and executes operating system TPM administrative command requests.
Provides BIOS Setup options to change TPM security states and to clear TPM ownership.
For additional details, refer to the TCG PC Client Specific Implementation Specification, the
TCG PC Client Specific Physical Presence Interface Specification, and the Microsoft BitLocker*
84 Intel order number G34153-003 Revision 1.2
System Security
Requirement documents.
5.2.2 Physical Presence
Administrative operations to the TPM require TPM ownership or physical presence indication by the operator to confirm the execution of administrative operations. The BIOS implements the operator presence indication by verifying the setup Administrator password.
A TPM administrative sequence invoked from the operating system proceeds as follows:
1.
User makes a TPM administrative request through the operating system’s security software.
2. The operating system requests the BIOS to execute the TPM administrative command through TPM
ACPI methods and then resets the system.
3. The BIOS verifies the physical presence and confirms the command with the operator.
4. The BIOS executes TPM administrative command(s), inhibits BIOS Setup entry and boots
directly to the operating system which requested the TPM command(s).
5.2.3 TPM Security Setup Options
The BIOS TPM Setup allows the operator to view the current TPM state and to carry out rudimentary TPM administrative operations. Performing TPM administrative options through the
BIOS setup requires TPM physical presence verification.
Using BIOS TPM Setup, the operator can turn ON or OFF TPM functionality and clear the TPM ownership contents. After the requested TPM BIOS Setup operation is carried out, the option reverts to No Operation.
The BIOS TPM Setup also displays the current state of the TPM, whether TPM is enabled or disabled and activated or deactivated. Note that while using TPM, a TPM-enabled operating system or application may change the TPM state independent of the BIOS setup. When an operating system modifies the TPM state, the BIOS Setup displays the updated TPM state.
The BIOS Setup TPM Clear option allows the operator to clear the TPM ownership key and allows the operator to take control of the system with TPM. You use this option to clear security settings for a newly initialized system or to clear a system for which the TPM ownership security key was lost.
5.2.3.1 Security Screen
To enter the BIOS Setup, press the F2 function key during boot time when the OEM or Intel logo displays. The following message displays on the diagnostics screen and under the Quiet Boot logo screen:
Press <F2> to enter setup
When the Setup is entered, the Main screen displays. The BIOS Setup utility provides the
Security screen to enable and set the user and administrative passwords and to lock out the front panel buttons so they cannot be used. The Intel
®
Server Board S5520URT provides TPM settings through the security screen.
To access this screen from the Main screen, select the Security option.
Revision 1.2 Intel order number G34153-003 85
System Security
Main Advanced
Main Advanced Security
Administrator Password Status
User Password Status
Set Administrator Password
Set User Password
Front Panel Lockout
TPM State
TPM Administrative Control
Server Management
<Installed/Not Installed>
<Installed/Not Installed>
[1234aBcD]
[1234aBcD]
Enabled/Disabled
Boot Options Boot Manager
<Enabled & Activated/Enabled & Deactivated/Disabled &
Activated/Disabled & Deactivated>
No Operation/Turn On/Turn Off/Clear Ownership
Figure 26. Setup Utility
– TPM Configuration Screen
Setup Item
TPM State*
TPM
Administrative
Control**
Table 28. TSetup Utility
– Security Configuration Screen Fields
Options
Enabled and
Activated
Enabled and
Deactivated
Disabled and
Activated
Disabled and
Deactivated
No Operation
Turn On
Turn Off
Clear Ownership
Help Text
[No Operation] - No changes to current state.
[Turn On] - Enables and activates
TPM.
[Turn Off] - Disables and deactivates
TPM.
Comments
Information only.
Shows the current TPM device state.
A disabled TPM device will not execute commands that use TPM functions and TPM security operations will not be available.
An enabled and deactivated TPM is in the same state as a disabled
TPM except setting of TPM ownership is allowed if not present already.
An enabled and activated TPM executes all commands that use
TPM functions and TPM security operations will be available.
86 Intel order number G34153-003 Revision 1.2
System Security
Setup Item Options Help Text
[Clear Ownership] - Removes the
TPM ownership authentication and returns the TPM to a factory default state.
Note: The BIOS setting returns to
[No Operation] on every boot cycle by default.
Comments
5.3 Intel
®
The Intel
®
Xeon
®
Processor E5-4600/2600/2400/1600 Product Families support Intel
Execution Technology (Intel
®
®
Trusted
TXT), which is a robust security environment. Designed to help protect against software-based attacks, Intel
®
Trusted Execution Technology integrates new security features and capabilities into the processor, chipset and other platform components.
When used in conjunction with Intel
®
Virtualization Technology, Intel
®
Trusted Execution
Technology provides hardware-rooted trust for your virtual applications.
This hardware-rooted security provides a general-purpose, safer computing environment capable of running a wide variety of operating systems and applications to increase the confidentiality and integrity of sensitive information without compromising the usability of the platform.
Intel
®
Trusted Execution Technology requires a computer system with Intel
®
Virtualization
Technology enabled (both VT-x and VT-d), an Intel
®
Trusted Execution Technology-enabled processor, chipset and BIOS, Authenticated Code Modules, and an Intel
®
Trusted Execution
Technology compatible measured launched environment (MLE). The MLE could consist of a virtual machine monitor, an OS or an application. In addition, Intel
®
Trusted Execution
Technology requires the system to include a TPM v1.2, as defined by the Trusted Computing
Group TPM PC Client specifications, Revision 1.2.
When available, Intel Trusted Execution Technology can be enabled or disabled in the processor by a BIOS Setup option.
For general information about Intel
®
TXT, visit the Intel
®
Trusted Execution Technology website, http://www.intel.com/technology/security/ .
Revision 1.2 Intel order number G34153-003 87
Connector/Header Locations and Pin-outs Intel® Workstation Board W2600CR TPS
6. Connector/Header Locations and Pin-outs
6.1 Power Connectors
6.1.1 Main Power Connector
Main server board power is supplied by one 12-pin power connector. The connector is labeled as “MAIN
PWR” on the left bottom of the server board. The following tables provide the pin-out for “MAIN PWR” connector.
Table 29. Main Power Connector Pin-out
8
9
10
11
12
4
5
6
7
Pin
1
2
3
Signal name
P3V3
P3V3
GND
P5V
GND
P5V
GND
PWRGD_PS_PWROK_PSU_R1
P5V_STBY_PSU
P12V
P12V
P3V3
20
21
22
23
24
Pin
13
14
15
16
17
18
19
Signal name
P3V3
N12V
GND
FM_PS_EN_PSU_N
GND
GND
GND
NC_PS_RES_TP
P5V
P5V
P5V
GND
6.1.2 CPU Power Connectors
On the server board are two white 8pin CPU power connectors labeled “CPU_1 PWR” and “CPU_2
PWR”. The following table provides the pin-out for both connectors.
Pin
1
2
3
4
GND
GND
GND
GND
Table 30. CPU_1 Power Connector Pin-out
Signal name Pin
5
6
7
8
P12V1
P12V1
P12V3A
P12V3A
Signal name
Table 31. CPU_2 Power Connector Pin-out
Pin
1
2
3
4
GND
GND
GND
GND
Signal name Pin
5
6
7
8
P12V2
P12V2
P12V3B
P12V3B
Signal name
6.1.3 Add-in Card Power Connectors
The serve board includes white 2x2-pin power connectors that provide supplemental power to high power PCIe x16 add-in cards (Video or GPGPU) that have power requirements that exceed the maximum power supplied by the riser slot. A cable from this connector may be routed to a matching connector on a riser card designed to support it or directly to the add-in cards that need them. Available power to each of these connectors is limited by the amount of
88 Intel order number G34153-003 Revision 1.2
Server Board S2600IP and Intel® Connector/Header Locations and Pin-outs power provided by the power supply and the total power draw for the rest of the system. A power budget for the complete system should be performed to determine how much supplemental power is available to support any high power add-in cards.
Each connector is labeled as “OPT_12V_PWR” on the server board. The following table provides the pin-out for both connectors.
15
17
19
21
23
25
27
29
Pin
1
3
5
7
9
11
13
Table 32. Add-in Slot Power Pin-input ("OPT_12V_PWR")
Pin
1
2
Signal Name
GND
GND
Pin Signal Name
3 +12V
4 +12V
6.2 Front Panel Header and Connectors
The server board includes several connectors that provide various possible front panel options. This section provides a functional description and pin-out for each connector.
6.2.1 Front Panel Header
Included on the left edge of the server board is a 30-pin header consists of a 24-pin SSI compatible front panel header and a 4-pin header to support optional NIC3/4 LEDs. The 24-pin
SSI front panel header provides various front panel features including:
Power/Sleep Button
System ID Button
NMI Button
NIC Activity LEDs
Hard Drive Activity LEDs
System Status LED
System ID LED
The following table provides the pin-out for this 30-pin header.
Table 33. Front Panel Header Pin-out
P3V3_AUX
Signal name
Key
FP_PWR_LED_BUF_N
P3V3
LED_HDD_ACTIVITY_N
FP_PWR_BTN_N
GND
FP_RST_BTN_N
GND
FP_ID_BTN_N
PU_FM_SIO_TEMP_SENSOR
FP_NMI_BTN_N
<Empty Pin>
LED_NIC_LINK2_ACT_FP_N
LED_NIC_LINK2_LNKUP_FP_N
16
18
20
22
24
26
28
30
Pin
2
4
6
8
10
12
14
Signal name
P3V3_AUX
P5V_STBY
FP_ID_LED_BUF_N
FP_LED_STATUS_GREEN_BUF_N
FP_LED_STATUS_AMBER_BUF_N
LED_NIC_LINK0_ACT_BUF_N
LED_NIC_LINK0_LNKUP_BUF_N
SMB_SENSOR_3V3STBY_DATA
SMB_SENSOR_3V3STBY_CLK
FP_CHASSIS_INTRUSION
LED_NIC_LINK1_ACT_BUF_N
LED_NIC_LINK1_LNKUP_BUF_N
<Empty Pin>
LED_NIC_LINK3_ACT_FP_N
LED_NIC_LINK3_LNKUP_FP_N
Revision 1.2 Intel order number G34153-003 89
Connector/Header Locations and Pin-outs Intel® Workstation Board W2600CR TPS
6.2.2 Front Panel USB Connector
The server board includes a 10-pin connector, that when cabled, can provide up to two USB ports to a front panel. The following table provides the connector pin-out.
Table 34. Front Panel USB Connector Pin-out
Pin
1
3
5
7
9
Signal Name
P5V_USB_FP
USB2_P13_F_DN
USB2_P13_F_DP
GND
KEY
Pin
2
Signal Name
P5V_USB_FP
4
6
USB2_P11_F_DN
USB2_P11_F_DP
8 GND
10 NA
6.2.3 Local Control Panel Connector
The server board includes a 7-pin connector that is used when the system is configured with the
Intel Local Control Panel with LCD support. The following table provides the pin-out for this connector.
Table 35. Local Front Panel Connector Pin-out
Pin
1
3
5
7
Signal Name
SMB_SENSOR_3V3STBY_DATA
SMB_SENSOR_3V3STBY_CLK
FM_LCP_ENTER_N
FM_LCP_RIGHT_N
6.3 On Board Storage Connectors
Pin
2
4
6
Signal Name
GND
P3V3_AUX
FM_LCP_LEFT_N
The server board provides connectors for support of several storage device options. This section provides a functional overview and pin-out of each connector.
6.3.1 SATA Connectors: 6Gbps
The board includes two white single port SATA only connectors capable of transfer rates of up to 6Gb/s. The following table provides the pin-out for both connectors.
Table 36. SATA 6Gbps Connector Pin-out
Pin
1
2
3
4
5
6
7
Signal Name
GND
SATA_TX_P
SATA_TX_N
GND
SATA_RX_N
SATA_RX_P
GND
90 Intel order number G34153-003 Revision 1.2
Server Board S2600IP and Intel® Connector/Header Locations and Pin-outs
6.3.2 Multiport Mini-SAS/SATA Connectors
The board includes two 40-pin high density multiport mini-SAS/SATA connectors. On the board, these connectors are labeled as “SCU0 port(0-3)” supporting the chipset embedded SCU0 controller, and “SCU1 Port(4-7)”, supporting the embedded SCU1 controller. Both connectors can support up to four SATA or SAS ports each. By default, only the connector labeled “SCU0
Port(0-
3)” is enabled and has support for up to four SATA ports capable. The connector labeled
“SCU1 Port(4-7)” is only enabled when an optional 8-port SAS or SATA Intel ®
RAID C600
Upgrade Key is installed. The following tables provide the pin-out for each connector.
Table 37. Multiport SAS/SATA Connector Pin-out ("SCU_0 (0-3)")
Pin
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
A11
A12
A13
Pin
A1
A2
A3
A4
A5
A6
A7
GROUND
SAS0_RX_C_DP
SAS0_RX_C_DN
GROUND
Signal name
A8
A9
A10
A11
A12
A13
A14
A15
SAS1_RX_C_DP
SAS1_RX_C_DN
GROUND
TP_SAS1_BACKPLANE_TYPE
GROUND
SGPIO_SAS1_DATAOUT
SGPIO_SAS1_DATAIN
A16
A17
A18
GROUND
SAS2_RX_C_DP
SAS2_RX_C_DN
GROUND
SAS3_RX_C_DP
SAS3_RX_C_DN
GROUND
MTH1 GROUND
MTH2 GROUND
MTH3 GROUND
MTH4 GROUND
Pin
B1
B2
B3
B4
B5
B6
B7
GROUND
SAS0_TX_C_DP
SAS0_TX_C_DN
GROUND
Signal name
SAS1_TX_C_DP
SAS1_TX_C_DN
GROUND
B8
B9
SGPIO_SAS1_CLOCK
SGPIO_SAS1_LOAD
B10 GROUND
B11 PD_SAS1_CONTROLLER_TYPE
B12 GROUND
B13 SAS2_TX_C_DP
B14 SAS2_TX_C_DN
B15 GROUND
B16 SAS3_TX_C_DP
B17 SAS3_TX_C_DN
B18 GROUND
MTH5 GROUND
MTH6 GROUND
MTH7 GROUND
MTH8 GROUND
Table 38. Multiport SAS/SATA Connector Pin-out ("SCU_1 (4-7)")
Signal name
GROUND
SAS4_RX_C_DP
SAS4_RX_C_DN
GROUND
SAS5_RX_C_DP
SAS5_RX_C_DN
GROUND
TP_SAS2_BACKPLANE_TYPE
GROUND
SGPIO_SAS2_DATAOUT
SGPIO_SAS2_DATAIN
GROUND
SAS6_RX_C_DP
Pin
B1
B2
B3
B4
Signal name
GROUND
SAS4_TX_C_DP
SAS4_TX_C_DN
GROUND
B5
B6
B7
B8
SAS5_TX_C_DP
SAS5_TX_C_DN
GROUND
SGPIO_SAS2_CLOCK
B9 SGPIO_SAS2_LOAD
B10 GROUND
B11 PD_SAS2_CONTROLLER_TYPE
B12 GROUND
B13 SAS6_TX_C_DP
Revision 1.2 Intel order number G34153-003 91
Connector/Header Locations and Pin-outs Intel® Workstation Board W2600CR TPS
Pin
A14
A15
A16
A17
A18
Signal name
SAS6_RX_C_DN
GROUND
SAS7_RX_C_DP
SAS7_RX_C_DN
GROUND
MTH1 GROUND
MTH2 GROUND
MTH3 GROUND
MTH4 GROUND
Pin Signal name
B14 SAS6_TX_C_DN
B15 GROUND
B16 SAS7_TX_C_DP
B17 SAS7_TX_C_DN
B18 GROUND
MTH5 GROUND
MTH6 GROUND
MTH7 GROUND
MTH8 GROUND
6.3.3
Intel
®
Key Connector
The server board provides one connector to support Intel
®
RAID C600 Upgrade Key. The Intel
®
RAID
C600 Upgrade Key is a small PCB board that enables different versions of RAID 5 software stack and/or upgrade from SATA to SAS storage functionality. The pin configuration of connector is identical and defined in the following table.
Table 39. Intel
®
RAID C600 Upgrade Key Connector Pin-out
6.3.4
Pin
1
2
3
4
Signal Name
GND
FM_PBG_DYN_SKU_KEY
GND
FM_SSB_SAS_SATA_RAID_KEY
HSBP_I2C Header
Table 40. HSBP_I2C Header Pin-out
Pin
1
2
3
Signal Name
SMB_HSBP_3V3STBY_DATA
GND
SMB_HSBP_3V3STBY_CLK
6.3.5 HDD LED Header
The server board includes a 2-pin hard drive activity LED header used with some SAS/SATA controller add-in cards. The header has the following pin-out.
Table 41. HDD LED Header Pin-out
Pin
1
Signal Name
LED_HDD_ACT_N
Pin
2 NA
Signal Name
6.3.6 Internal Type- A USB Connector
The server board includes two internal Type-A USB connector. The following table provides the pin-out for this connector.
Pin
1
3
Table 42. Type-A USB Connector Pin-out
Signal Name
P5V
USB2_P2_F_DP
Pin
2
4
Signal Name
USB2_P2_F_DN
GND
92 Intel order number G34153-003 Revision 1.2
Server Board S2600IP and Intel® Connector/Header Locations and Pin-outs
6.3.7 Internal eUSB SSD Header
The server board includes one 10-pin internal eUSB header with an intended usage of supporting USB
SSD devices. The following table provides the pin-out for this connector.
Table 43. eUSB SSD Header Pin-out
Pin
1
3
5
7
9
Signal Name
5V
USB2_P0_DN
USB2_P0_DP
GND
Key
Pin
2
4
6
Signal Name
NC
NC
NC
8 NC
10 LED_HDD_ACT_ZEPHER_N
6.4 Management and Security Connectors
6.4.1 RMM4_Lite Connector
A 7-pin Intel ® RMM4 Lite connector is included on the server board to support the optional Intel ® Remote
Management Module 4. There is no support for third-party management cards on this server board.
Pin
1
3
5
7
Table 44. RMM4_Lite Connector Pin-out
Signal Name
P3V3_AUX
KEY
DO
CS_N
Pin
2
4
6
8
DI
CLK
Signal Name
GND
GND
6.4.2 RMM4_NIC Connector
Table 45. RMM4_NIC Connector Pin-out
Pin
1
3
5
7
Signal Name
3V3_AUX
3V3_AUX
GND
GND
9 GND
11 GND
13 GND
15 GND
17 GND
19 GND
21 GND
23 GND
25 GND
27 GND
29 GND
10
12
14
16
18
20
Pin
2
4
6
8
22
24
26
28
30
Signal Name
MDIO
MDC
TXD_0
TXD_1
TXD_2
TXD_3
TX_CTL
RX_CTL
RXD_0
RXD_1
RXD_2
RXD_3
TX_CLK
RX_CLK
PRESENT#
Revision 1.2 Intel order number G34153-003 93
Connector/Header Locations and Pin-outs Intel® Workstation Board W2600CR TPS
6.4.3 TPM Connector
Table 46. TPM Connector Pin-out
Pin
1
3
5
7
9
Key
Signal Name
LPC_LAD<0>
IRQ_SERIAL
P3V3
RST_IBMC_NIC_N_R2
11 LPC_LAD<3>
13 GND
Pin
2
4
Signal Name
LPC_LAD<1>
GND
6
8
LPC_FRAME_N
GND
10 CLK_33M_TPM
12 GND
14 LPC_LAD<2>
6.4.4 PMBus* Connector
Table 47. PMBus* Connector Pin-out
Pin
1
2
3
4
5
Signal name
SMB_PMBUS_CLK_R
SMB_PMBUS_DATA_R
IRQ_SML1_PMBUS_ALERT_RC_N
GND
P3V3
6.4.5 Chassis Intrusion Header
The server board includes a 2-pin chassis intrusion header which can be used when the chassis is configured with a chassis intrusion switch. The header has the following pin-out.
Table 48. Chassis Intrusion Header Pin-out
6.4.6
Header State
Pins 1 and 2 closed
Pins 1 and 2 open
IPMB Connector
Description
FM_INTRUDER_HDR_N is pulled HIGH. Chassis cover is closed.
FM_INTRUDER_HDR_N is pulled LOW. Chassis cover is removed.
Table 49. IPMB Connector Pin-out
6.5 FAN Connectors
Pin
1
2
3
4
Signal Name
SMB_IPMB_5VSTBY_DATA
GND
SMB_IPMB_5VSTBY_CLK
P5V_STBY
The server board provides support for nine fans. Seven of them are system cooling fans, two of them are CPU fans.
94 Intel order number G34153-003 Revision 1.2
Server Board S2600IP and Intel® Connector/Header Locations and Pin-outs
6.5.1 System FAN Connectors
The six system cooling fan connectors near the front edge of the board are 6-Pin connectors; the one system cooling fan near edge of the board is a 4-Pin connectors. Following table provides the pin-out for all system fan connectors.
Table 50. 6-pin System FAN Connector Pin-out
Pin
1
2
3
4
5
6
Signal Name
GND
12V
TACH
PWM
PRSNT
FAULT
Table 51. 4-pin System FAN Connector Pin-out
Pin
1
2
3
4
Signal Name
GND
12V
TACH
PWM
6.5.2 CPU FAN Connector
The two CPU fan connectors are 4-pin fan connectors. Following table provides the pin-out for
CPU fan connectors.
Table 52. CPU FAN Connector Pin-out
Pin
1
2
3
4
Signal Name
GND
12V
TACH
PWM
6.6 Serial Port and Video Connectors
The server board includes two serial port connectors.
6.6.1 Serial Port A Connector (DB9, for Intel
®
Server Board S2600IP only)
Serial-A is an external RJ45 type connector and has the following pin-out configuration.
Pin
1
3
5
7
9
Table 53. Serial Port A Connector Pin-out
Signal Name
SPA_DCD
SPA_SOUT_N
GND
SPA_RTS
SPA_RI
Pin
2
4
6
8
SPA_SIN
SPA_DTR
SPA_DSR
SPA_CTS
Signal Name
Revision 1.2 Intel order number G34153-003 95
Connector/Header Locations and Pin-outs Intel® Workstation Board W2600CR TPS
6.6.2 Serial Port B Connector
Serial-B is an internal 10-pin DH-10 connector and has the following pin-out.
Table 54. Serial Port B Connector Pin-out
Pin
1
3
5
7
9
Signal Name
SPA_DCD
SPA_SIN
SPA_SOUT_N
SPA_DTR
GND
Pin
2
4
6
8
Signal Name
SPA_DSR
SPA_RTS
SPA_CTS
SPA_RI
6.6.3 Video Connector (For Intel
®
Server Board S2600IP only)
The following table details the pin-out definition of the external VGA connector.
Table 55. Video Connector Pin-out details
8
9
10
11
12
13
14
15
4
5
6
7
Pin
1
2
3
CRT_RED
CRT_GREEN
CRT_BLUE
Signal Name
N/C
GND
GND
GND
GND
P5V
GND
NC
CRT_DDCDATA
CRT_HSYNC
CRT_VSYNC
CRT_DDCCLK
96
Figure 27. Video Connector Pin-out
Intel order number G34153-003 Revision 1.2
Server Board S2600IP and Intel® Connector/Header Locations and Pin-outs
6.6.4 Internal Video header (For Intel
®
Workstation Board W2600CR only)
7
8
9
10
11
12
13
14
Pin
1
2
3
4
5
6
Signal Name
CRT_RED
GND
CRT_Green
GND
CRT_Blue
GND
CRT_VSYNC
GND
CRT_HSYN
Key
CRT_DDCDATA
VIDEO_IN_USE signal
CRT_DDCCLK
5V
Note: Intel
®
Corporation server boards support peripheral components and can contain a number of high-density VLSI and power delivery components that need adequate airflow to cool.
Intel’s own chassis are designed and tested to meet the intended thermal requirements of these components when the fully integrated system is used together. It is the responsibility of the system integrator that chooses not to use Intel
®
developed server building blocks to consult vendor datasheets and operating parameters to determine the amount of airflow required for their specific application and environmental conditions. Intel Corporation cannot be held responsible if components fail or the server board does not operate correctly when used outside any of its published operating or non-operating limits.
Revision 1.2 Intel order number G34153-003 97
Jumper Blocks
7. Jumper Blocks
The server boards have several 3-pin jumper blocks that you can use to configure, protect, or recover specific features of the server boards.
The following symbol identifies Pin 1 on each jumper block on the silkscreen:
▼
Figure 28. Jumper Blocks (J1C3, J1F1, J1F2, J2F3, J2F2)
Table 56. Server Board Jumpers (J1C3, J1F1, J1F2, J2F3, J2F2)
Jumper Name
J1F2: BIOS Recovery
J1F1: Bios Default
(CMOS Clear)
Pins System Results
1-2 Pins 1-2 should be connected for normal system operation. (Default)
2-3
1-2
2-3
J2F2: ME Force 1-2
The main system BIOS does not boot with pins 2-3 connected. The system only boots from EFI-bootable recovery media with a recovery BIOS image present.
These pins should have a jumper in place for normal system operation.
(Default)
If pins 2-3 are connected when AC power unplugged, the CMOS settings clear in 5 seconds. Pins 2-3 should not be connected for normal system operation.
ME Firmware Force Update Mode
– Disabled (Default)
98 Intel order number G34153-003 Revision 1.2
Jumper Blocks
Jumper Name
Update
J1C1: BMC Force
Update
J2F3: Password Clear
Pins System Results
2-3
1-2
2-3
ME Firmware Force Update Mode
– Enabled
BMC Firmware Force Update Mode
– Disabled (Default)
BMC Firmware Force Update Mode
– Enabled
1-2
These pins should have a jumper in place for normal system operation.
(Default)
2-3
To clear administrator and user passwords, power on the system with pins 2-3 connected. The administrator and user passwords clear in 5-10 seconds after power on. Pins 2-3 should not be connected for normal system operation.
7.1 BIOS Default and Password Reset Usage Procedure
The BIOS Default (CMOS Clear) and Password Reset recovery features are designed to achieve the desired operation with minimum system down time. The usage procedure for these two features has changed from previous generation Intel
®
boards. The following procedure outlines the new usage model.
7.1.1 Set BIOS to default (Clearing the CMOS)
1. Power down the server and unplug the AC power cord.
2. Open the server chassis. For instructions, see your server chassis documentation.
3. Move the jumper from the default operating position (covering pins 1 and 2) to the reset/clear position (covering pins 2 and 3).
4. Wait five seconds.
5. Move the jumper back to the default position, covering pins 1 and 2.
6. Close the server chassis and reconnect the AC power cord.
7. Power up the server.
The CMOS is now cleared and you can reset it by going into the BIOS setup.
Note: Removing AC power before performing the CMOS clear operation causes the system to automatically power up and immediately power down, after the procedure is followed and AC power is re-applied. If this happens, remove the AC power cord again, wait 30 seconds, and reinstall the AC power cord. Power up the system and proceed to the <F2> BIOS Setup utility to reset the preferred settings.
7.1.2 Clearing the Password
1. Power down the server. Do not unplug the power cord.
2. Open the chassis. For instructions, see your server chassis documentation.
3. Move the jumper from the default operating position (covering pins 1 and 2) to the password clear position (covering pins 2 and 3).
4. Close the server chassis.
5. Power up the server and then press <F2> to enter the BIOS menu to check if the password is cleared.
6. Power down the server.
Revision 1.2 Intel order number G34153-003 99
Jumper Blocks
7. Open the chassis and move the jumper back to its default position (covering pins 1 and 2).
8. Close the server chassis.
9. Power up the server.
The password is now cleared and you can reset it by going into the BIOS setup.
7.2 Force BMC Update Procedure
When performing a standard BMC firmware update procedure, the update utility places the
BMC into an update mode, allowing the firmware to load safely onto the flash device. In the unlikely event the BMC firmware update process fails due to the BMC not being in the proper update state, the server boards provide a Force BMC Update jumper that forces the BMC into the proper update state. In the event the standard BMC firmware update process fails, complete the following procedure:
1. Power down and remove the AC power cord.
2. Open the server chassis. See your server chassis documentation for instructions.
3. Move the jumper from the default operating position (covering pins 1 and 2) to the enabled position (covering pins 2 and 3).
4. Close the server chassis.
5. Reconnect the AC power cord and power up the server.
6. Perform the BMC firmware update procedure as documented in the BMC firmware update package. After successful completion of the firmware update process, the firmware update utility may generate an error stating the BMC is still in update mode.
7. Power down and remove the AC power cord.
8. Open the server chassis.
9. Move the jumper from the enabled position (covering pins 2 and 3) to the disabled position
(covering pins 1 and 2).
10. Close the server chassis.
11. Reconnect the AC power cord and power up the server.
Note: When the Force BMC Update jumper is set to the enabled position, normal BMC functionality is disabled. You should never run the server with the Force BMC Update jumper set in this position. You should only use this jumper setting when the standard firmware update process fails. When the server is running normally, this jumper must remain in the default/disabled position.
7.3 BIOS Recovery Jumper
The following procedure boots the recovery BIOS and flashes the normal BIOS:
1. Turn off the system power.
2. Move the BIOS recovery jumper to the recovery state.
3. Insert a bootable BIOS recovery media containing the new BIOS image files.
4. Turn on the system power.
100 Intel order number G34153-003 Revision 1.2
Jumper Blocks
The BIOS POST screen will appear displaying the progress, and the system will boot to the EFI shell.
The EFI shell then executes the Startup.nsh batch file to start the flash update process. The user should then switch off the power and return the recovery jumper to its normal position. The user should not interrupt the BIOS POST on the first boot after recovery.
When the flash update completes:
1. Remove the recovery media.
2. Turn off the system power.
3. Restore the jumper to its original position.
4. Turn on the system power.
5. Re-flash any custom blocks, such as user binary or language blocks.
The system should now boot using the updated system BIOS.
7.4 ME Force Update Jumper
When performing the standard ME force update procedure, the update utility places the ME into an update mode, allowing the ME to load safely onto the flash device. In the unlikely event ME firmware update process fails due to ME not being in the proper update state, the server board provides an
Integrated BMC Force Update jumper, which forces the ME into the proper update state. The following procedure should be completed in the event the standard ME firmware update process fails.
1. Power down and remove the AC power cord.
2. Open the server chassis. For instructions, see your server chassis documentation.
3. Move jumper from the default operating position (covering pins 1 and 2) to the enabled position
(covering pins 2 and 3).
4. Close the server chassis.
5. Reconnect the AC cord and power up the server.
6. Perform the ME firmware update procedure as documented in the README.TXT file that is included in the given ME firmware update package (same package as BIOS).
7. Power down and remove the AC power cord.
8. Open the server chassis.
9. Move jumper from the enabled position (covering pins 2 and 3) to the disabled position (covering pins 1 and 2).
10. Close the server chassis.
11. Reconnect the AC cord and power up the server.
Revision 1.2 Intel order number G34153-003 101
8. Intel
®
Light Guided Diagnostics
Both server boards have several onboard diagnostic LEDs to assist in troubleshooting board-level issues.
This section provides a description of the location and function of each LED on the server boards.
8.1 5-volt Stand-by LED
Several server management features of these server boards require a 5-V stand-by voltage supplied from the power supply. The features and components that require this voltage must be present when the system is “power-down”. The LED is illuminated when AC power is applied to the platform and 5-V standby voltage is supplied to the server board by the power supply.
8.2 Fan Fault LED
Fan fault LEDs are present for the two CPU fans and the one rear system fan. The fan fault LEDs illuminate when the corresponding fan has fault.
8.3 CPU Fault LED
CPU fault LED should correspond to the socket with the failed or disabled CPU. The CPU LEDs illuminate when CPU failure or Disable.
102 Intel order number G34153-003 Revision 1.2
Figure 29. Stand by LED, Fan Fault LED and CPU Fault LED Location
Revision 1.2 Intel order number G34153-003 103
8.4 DIMM Fault LEDs
The server board provide memory fault LED for each DIMM socket. These LEDs are located as shown in the following figure. The DIMM fault LED illuminates when the corresponding DIMM slot has memory installed and a memory error occurs.
Figure 30
. DIMM Fault LED’s Location
8.5 System ID LED, System Status LED and POST Code Diagnostic LEDs
The server boards provide LEDs for system ID, system status and POST code. These LEDs are located in the rear I/O area of the server board as shown in the following figure.
104 Intel order number G34153-003 Revision 1.2
Figure 31. Location of System Status, System ID and POST Code Diagnostic LEDs
LED Name
A
B
LSB 1 2 3 4 5 6 MSB
Description
System Status LED
System ID LED
Post Code Diagnostic LEDs
8.5.1 System ID LED
You can illuminate the blue System ID LED using either of the following two mechanisms:
By pressing the System ID Button on the system front control panel, the ID LED displays a solid blue color until the button is pressed again.
By issuing the appropriate hex IPMI “Chassis Identify” value, the ID LED will either blink blue for
15 seconds and turn off or will blink indefinitely until the appropriate hex IPMI Chassis Identify value is issue to turn it off.
Revision 1.2 Intel order number G34153-003 105
8.5.2 System Status LED
The bi-color (green/amber) System Status LED operates as follows:
Table 57. System Status LED
Color State
Green Solid on Ok
Criticality Description
Indicates that the System Status is ‘Healthy’. The system is not exhibiting any errors. AC power is present and BMC has booted and manageability functionality is up and running.
Green ~1 Hz blink Degraded
System degraded:
1. Redundancy loss such as power-supply or fan. Applies only if the associated platform sub-system has redundancy capabilities.
2. Fan warning or failure when the number of fully operational fans is more than minimum number needed to cool the system.
3. Non-critical threshold crossed
– Temperature (including HSBP temp), voltage, input power to power supply, output current for main power rail from power supply and Processor Thermal Control (Therm Ctrl) sensors.
4. Power supply predictive failure occurred while redundant power supply configuration was present.
5. Unable to use all of the installed memory (more than 1 DIMM installed).
6. Correctable Errors over a threshold and migrating to a spare DIMM
(memory sparing). This indicates that the user no longer has spared
DIMMs indicating a redundancy lost condition. Corresponding DIMM LED lit.
7. In mirrored configuration, when memory mirroring takes place and system loses memory redundancy.
8. Battery failure.
9. BMC executing in uBoot. (Indicated by Chassis ID blinking at Blinking at
3Hz). System in degraded state (no manageability). BMC uBoot is running but has not transferred control to BMC Linux. Server will be in this state 6-
8 seconds after BMC reset while it pulls the Linux image into flash
10. BMC booting Linux. (Indicated by Chassis ID solid ON). System in degraded state (no manageability). Control has been passed from BMC uBoot to BMC Linux itself. It will be in this state for ~10-~20 seconds.
11. BMC Watchdog has reset the BMC.
12. Power Unit sensor offset for configuration error is asserted.
13. HDD HSC is off-line or degraded.
Amber ~1 Hz blink Non-critical
Non-fatal alarm
– system is likely to fail:
1. Critical threshold crossed
– Voltage, temperature (including HSBP temp), input power to power supply, output current for main power rail from power supply and PROCHOT (Therm Ctrl) sensors.
2. VRD Hot asserted.
3. Minimum number of fans to cool the system not present or failed
4. Hard drive fault
5. Power Unit Redundancy sensor
– Insufficient resources offset (indicates not enough power supplies present).
6. In non-sparing and non-mirroring mode if the threshold of correctable errors is crossed within the window
106 Intel order number G34153-003 Revision 1.2
Color State
Amber Solid on
Criticality
Critical, nonrecoverable
Description
Fatal alarm
– system has failed or shutdown:
1. CPU CATERR signal asserted.
2. MSID mismatch detected (CATERR also asserts for this case).
3. CPU 1 is missing.
4. CPU ThermalTrip.
5. No power good
– power fault.
6. DIMM failure when there is only 1 DIMM present and hence no good memory present.
7. Runtime memory uncorrectable error in non-redundant mode 1.
8. DIMM Thermal Trip or equivalent.
9. SSB Thermal Trip or equivalent.
10. CPU ERR2 signal asserted.
11. BMC/Video memory test failed. (Chassis ID shows blue/solid-on for this condition).
12. Both uBoot BMC FW images are bad. (Chassis ID shows blue/solid on for this condition).
13. 13. 240VA fault
Not ready AC power off Off N/A
8.5.3 POST Code Diagnostic LEDs
During the system boot process, the BIOS executes a number of platform configuration processes, each of which is assigned a specific hex POST code number. As each configuration routine is started, the
BIOS displays the given POST code to the POST code diagnostic
LED’s on the back edge of the server boards. To assist in troubleshooting a system hang during the POST process, you can use the diagnostic
LEDs to identify the last POST process executed.
Table 58. POST Code Diagnostic LEDs
A. Diagnostic LED #7 (MSB LED)
B. Diagnostic LED #6
C. Diagnostic LED #5
D. Diagnostic LED #4
E. Diagnostic LED #3
F. Diagnostic LED #2
G. Diagnostic LED #1
H. Diagnostic LED #0 (LSB LED)
Revision 1.2 Intel order number G34153-003 107
Design and Environmental Specifications Intel® Workstation Board W2600CR TPS
9. Design and Environmental Specifications
9.1 Products Design Specifications
The following table defines the Intel operating and non-operating environmental limits. Operation of the Intel
Intel
®
®
Server Board S2600IP and Intel
®
Workstation Board W2600CR
®
Server Board S2600IP and
Workstation Board W2600CR at conditions beyond those shown in the following table may cause permanent damage to the system. Exposure to absolute maximum rating conditions for extended periods may affect system reliability.
Table 59. Server Board Design Specifications
Operating Temperature
Non-Operating Temperature
DC Voltage
Shock (Unpackaged)
0º C to 55º C
1
(32º F to 131º F)
-40º C to 70º C (-40º F to 158º F)
± 5% of all nominal voltages
Trapezoidal, 35g , 170 inches/sec
Shock (Packaged)
< 20 pounds
20 to < 40 pounds
40 to < 80 pounds
36 inches
30 inches
24 inches
80 to < 100 pounds
100 to < 120 pounds
120 pounds
18 inches
12 inches
9 inches
5 Hz to 500 Hz 3.13 g RMS random
Vibration (Unpackaged)
Note:
1.
Intel Corporation server boards contain a number of high-density VLSI and power delivery components that need adequate airflow to cool. Intel ensures through its own chassis development and testing that when Intel
®
server building blocks are used together, the fully integrated system will meet the intended thermal requirements of these components. It is the responsibility of the system integrator who chooses not to use Intel
®
developed server building blocks to consult vendor datasheets and operating parameters to determine the amount of airflow required for their specific application and environmental conditions. Intel Corporation cannot be held responsible if components fail or the server board does not operate correctly when used outside any of its published operating or non-operating limits.
Disclaimer Note: Intel
®
ensures the unpackaged server board and system meet the shock requirement mentioned above through its own chassis development and system configuration. It is the responsibility of the system integrator to determine the proper shock level of the board and system if the system integrator chooses different system configuration or different chassis. Intel Corporation cannot be held responsible, if components fail or the server board does not operate correctly when used outside any of its published operating or non-operating limits.
9.2 MTBF
The following is the calculated Mean Time Between Failures (MTBF) 30
C (ambient air). These values are derived using a historical failure rate and multiplied by factors for application, electrical and/or thermal stress and for device maturity. You should view
MTBF estimates as “reference numbers” only.
Calculation Model: Telcordia* Issue 2, method I case 3
Operating Temperature: Server in 30°C ambient air
Operating Environment: Ground Benign, Controlled
108 Intel order number G34153-003 Revision 1.2
Server Board S2600IP and Intel® Design and Environmental Specifications
Duty Cycle: 100%
Quality Level: II
Table 60. Intel
®
Server Board S2600IP MTBF Estimate
Assembly Name
Mother Board
Integrated Circuits
Transistor_Bipolar
Transistor_MOSFET
Diodes
Diodes_LED
Resistors
Capacitors
Cap, Al Elect
Inductors
Connections
Misc
Failure Rate
4,981.828605
888.017556
142.288706
394.540757
24.364143
30.002406
1,134.467959
379.972284
741.486991
148.990773
1,213.354514
94.901757
MTBF
200,730
1,126,104
7,027,965
2,534,592
41,043,923
33,330,661
881,470
2,631,771
1,348,641
6,711,825
824,161
10,537,213
Table 61. Intel
®
Workstation Board W2600CR MTBF Estimate
Assembly Name
Mother Board
Integrated Circuits
Transistor_Bipolar
Transistor_MOSFET
Diodes
Diodes_LED
Resistors
Capacitors
Cap, Al Elect
Inductors
Connections
Failure Rate
5,247.668190
951.031471
147.372000
404.110588
36.808324
30.002406
1,204.023273
413.065171
770.924084
175.282101
1,216.849949
MTBF
190,561
1,051,490
6,785,549
2,474,570
27,167,768
33,330,661
830,549
2,420,925
1,297,145
5,705,089
821,794
Revision 1.2 Intel order number G34153-003 109
Design and Environmental Specifications Intel® Workstation Board W2600CR TPS
Misc
Assembly Name Failure Rate
127.585507 7,837,881
MTBF
110 Intel order number G34153-003 Revision 1.2
Design and Environmental Specifications
9.3 Server Board Power Requirements
This section provides power supply design guidelines for a system using the Intel
®
Server Board S2600IP and Workstation Board W2600CR including voltage and current specifications, and power supply on/off sequencing characteristics. The following diagram shows the power distribution implemented on these server boards.
Revision 1.2
Figure 32. Power Distribution Block Diagram
Intel order number G34153-003 111
Appendix A: Integration and Usage Tips
9.3.1 Processor Power Support
The server boards support the Thermal Design Power (TDP) guideline for Intel
®
Xeon
® processors. The Flexible Motherboard Guidelines (FMB) is followed to determine the suggested thermal and current design values for anticipating future processor needs. The following table provides maximum values for DTS, TDP power and T
CASE
for the compatible Intel
®
E5-2600 processor family series.
Table 62. Intel
®
Xeon
®
Processor Dual Processor TDP profile
Max TDP Power
130W
150W
85°C
67°C
104.4 for 6 core
100 for 8 core
84.8
9.4
Power Supply Output Requirements
This section is for reference purposes only. The intent is to provide guidance to system designers to determine a power supply to use with these server boards. This section specifies the power supply requirements Intel used to develop a power supply for its server system.
9.4.1 Output Power/Currents
The following tables define the minimum power and current ratings. The power supply must meet both static and dynamic voltage regulation requirements for all conditions.
Table 63. Minimum Load Ratings
Parameter
3.3V
5V
12V1
12V2
12V3
12V
5Vstby
Min
0.5
0.3
0.7
0.7
1.5
0.0
0.0
Max.
18.0
15.0
24.0
24.0
18.0
0.5
3.0
Peak
28.0
28.0
3.5
Unit
A
A
A
A
A
A
A
Notes:
1. Combined continuous power for all output shall not exceed 550W.
2. Peak combined power for all outputs shall not exceed 630W for 20 seconds.
3. Max combined power of 12V1, 12V2, and 12V3 shall not exceed 530W.
4. Max combined power on 3.3V and 5V shall not exceed 120W.
9.4.2 Cross Loading
The power supply shall maintain voltage regulation limit when operated over the following cross loading conditions.
Intel order number G34153-003 Revision 1.2
Appendix A: Integration and Usage Tips
Table 64. Loading Conditions
Load1
Load2
Load3
Load4
Load5
Load6
Load7
3.3V
18
13.5
2.5
2.5
0.5
16
16
5V
12.1
15
2
2
0.3
4
13
12V1
12
12
20
13.1
15
1
1
12V2
12
12
20
13.1
15
1
1
12V3
11.7
11.2
4.2
18
6.5
3.5
9
-12V
0
0.5
0
0
0.5
0
0.5
5Vstby
0.3
0.3
0.3
0.3
3
0.3
3
Total
Power
550
549
550
550
462
140
271
12V
Power
428
422
530
530
438
66
132
9.4.3 Standby Output
The 5VSB output shall be present when an AC input greater than the power supply turn on voltage is applied.
9.4.4 Voltage Regulation
3.3V/5V
Power
120
120
18
18
3
73
118
The power supply output voltages must stay within the following voltage limits when operating at steady state and dynamic loading conditions. These limits include the peak-peak ripple/noise.
These shall be measured at the output connectors.
Table 65.Voltage Regulation Limits
Parameter
+3.3V
+5V
+12V1
+12V2
+12V3
- 12V
+5VSB
Tolerance
- 3%/+5%
- 4%/+5%
- 4%/+5%
- 4%/+5%
- 4%/+5%
- 10%/+10%
- 4%/+5%
Min
+3.20
+4.80
+11.52
+11.52
+11.52
- 13.20
+4.80
Nom
+3.30
+5.00
+12.00
+12.00
+12.00
-12.00
+5.00
Max
+3.46
+5.25
+12.60
+12.60
+12.60
-10.80
+5.25
Units
V rms
V rms
V rms
V rms
V rms
V rms
V rms
9.4.5 Dynamic Loading
The output voltages shall remain within limits specified for the step loading and capacitive loading specified in the table below. The load transient repetition rate shall be tested between
50Hz and 5kHz at duty cycles ranging from 10%-90%. The load transient repetition rate is only a test specification. The
step load may occur anywhere within the MIN load to the MAX load conditions.
Output
+3.3V
+5V
12V1+12V2+12V3
+5VSB
Table 66. Transient Load Requirements
Step Load Size
(See note 2)
6.0A
4.0A
23A
0.5A
Load Slew Rate
0.5 A/
sec
0.5 A/
sec
0.5 A/
sec
0.5 A/
sec
Test capacitive Load
970
F
400
F
2200
F
1,2
20
F
Revision 1.2 Intel order number G34153-003 113
Appendix A: Integration and Usage Tips
Notes:
1. Step loads on each 12V output may happen simultaneously.
2. The +12V should be tested with 2200
F evenly split between the four +12V rails
3. This will be tested over the range of load conditions in section 9.4.2
9.4.6 Capacitive Loading
The power supply shall be stable and meet all requirements with the following capacitive loading ranges.
Table 67. Capacitive Loading Conditions
Output
+3.3V
+5V
+12V
-12V
+5VSB
Min
250
400
500
1
20
Max
5000
5000
8000
350
350
Units
F
F
F
F
F
9.4.7 Grounding
The output ground of the pins of the power supply provides the output power return path. The output connector ground pins shall be connected to the safety ground (power supply enclosure).
This grounding should be well designed to ensure passing the max allowed Common Mode
Noise levels.
The power supply shall be provided with a reliable protective earth ground. All secondary circuits shall be connected to protective earth ground. Resistance of the ground returns to chassis shall not exceed 1.0 m
. This path may be used to carry DC current.
9.4.8 Closed loop stability
The power supply shall be unconditionally stable under all line/load/transient load conditions including capacitive load ranges specified in Section 4.6. A minimum of 45 degrees phase
margin and -10dB-gain margin is required. The power supply manufacturer shall provide proof of the unit’s closed-loop stability with local sensing through the submission of Bode plots.
Closed-loop stability must be ensured at the maximum and minimum loads as applicable.
9.4.9 Residual Voltage Immunity in Standby mode
The power supply should be immune to any residual voltage placed on its outputs (Typically a leakage voltage through the system from standby output) up to 500mV. There shall be no additional heat generated, nor stressing of any internal components with this voltage applied to any individual or all outputs simultaneously. It also should not trip the protection circuits during turn on.
The residual voltage at the power supply outputs for no load condition shall not exceed 100mV when AC voltage is applied and the PSON# signal is de-asserted.
9.4.10 Common Mode Noise
The Common Mode noise on any output shall not exceed 350mV pk-pk over the frequency band of 10
Hz to 20MHz. The measurement shall be made across a 100Ω resistor between each of DC outputs, including ground at the DC power connector and chassis ground (power subsystem enclosure). The test set-up shall use a FET probe such as Tektronix model P6046 or equivalent.
Intel order number G34153-003 Revision 1.2
Appendix A: Integration and Usage Tips
9.4.11 Soft Starting
The Power Supply shall contain control circuit which provides monotonic soft start for its outputs without overstress of the AC line or any power supply components at any specified AC line or load conditions.
9.4.12 Zero Load Stability Requirements
When the power subsystem operates in a no load condition, it does not need to meet the output regulation specification, but it must operate without any tripping of over-voltage or other fault circuitry. When the power subsystem is subsequently loaded, it must begin to regulate and source current without fault.
9.4.13 Ripple/Noise
The maximum allowed ripple/noise output of the power supply is defined in the table below. This is measured over a bandwidth of 10Hz to 20MHz at the power supply output connectors. A
10
F tantalum capacitor in parallel with a 0.1
F ceramic capacitor is placed at the point of measurement.
+3.3V
50mVp-p
Table 68. Ripples and Noise
+5V
50mVp-p
+12V1,2,3
120mVp-p
-12V
200mVp-p
+5VSB
50mVp-p
The test set-up is shown below.
AC HOT
POWER SUPPLY
AC NEUTRAL
V
OUT
V
RETURN
10uF
.1uF
LOAD
LOAD MUST BE
ISOLATED FROM
THE GROUND OF
THE POWER
SUPPLY
AC GROUND
GENERAL NOTES:
1. LOAD THE OUTPUT WITH ITS MINIMUM
LOAD CURRENT.
2. CONNECT THE PROBES AS SHOWN.
3. REPEAT THE MEASUREMENTS WITH THE
MAXIMUM LOAD ON THE OUTPUT.
SCOPE
SCOPE NOTE:
USE A TEKTRONIX 7834 OSCILLOSCOPE WITH 7A13 AND
DIFFERENTIAL PROBE P6055 OR EQUIVALENT.
Figure 33. Differential Noise test setup
Note:
When performing this test, the probe clips and capacitors should be located close to the load.
9.4.14 Timing Requirements
These are the timing requirements for the power supply operation. The output voltages must rise from 10% to within regulation limits (T vout_rise
) within 2 to 50ms, except for 5VSB - it is allowed to rise from 1 to 25ms. The +3.3V, +5V and +12V1,+12V2 ,+12V3 output voltages should start to rise approximately at the same time. All outputs must rise monotonically.
Each output voltage shall reach regulation within 50ms (T vout_on
) of each other during turn on of
Revision 1.2 Intel order number G34153-003 115
Appendix A: Integration and Usage Tips the power supply. Each output voltage shall fall out of regulation within 400ms (T vout_off
) of each
other during turn off. Table 69 shows the timing requirements for the power supply being turned
on and off by the AC input, with PSON held low and the PSON signal, with the AC input applied.
All timing requirements must be met for the cross loading condition in section TBD.
Item
T vout_rise
T vout_on
T vout_off
Table 69. Output Voltage Timing
Description
Output voltage rise time from each main output.
Output rise time for the 5Vstby output.
All main outputs must be within regulation of each other within this time.
All main outputs must leave regulation within this time.
Min
2
1
Max
50
25
50
400
Units ms ms ms ms
Vout
V1
V2
V3
V4
10%
Vout
Item
T sb_on_delay
T ac_on_delay
T vout_holdup
T pwok_holdup
T vout_rise
T vout_on
Figure 34. Output Voltage Timing
T vout_off
Table 70. Turn On/Off Timing
Description
Delay from AC being applied to 5VSB being within regulation.
Delay from AC being applied to all output voltages being within regulation.
Time all output voltages stay within regulation after loss of AC. Tested at 75% of maximum load.
Delay from loss of AC to de-assertion of PWOK.
Tested at 75% of maximum load.
MIN
13
12
MAX
1500
2500
UNITS ms ms ms ms
Intel order number G34153-003 Revision 1.2
Appendix A: Integration and Usage Tips
Item
T pson_on_delay
T pson_pwok
T pwok_on
T pwok_off
T pwok_low
T sb_vout
T
5VSB_holdup
AC Input
Description
Delay from PSON
#
active to output voltages within regulation limits.
Delay from PSON
#
deactivate to PWOK being deasserted.
Delay from output voltages within regulation limits to PWOK asserted at turn on.
Delay from PWOK de-asserted to output voltages
(3.3V, 5V, 12V, -12V) dropping out of regulation limits.
Duration of PWOK being in the de-asserted state during an off/on cycle using AC or the PSON signal.
Delay from 5VSB being in regulation to O/Ps being in regulation at AC turn on.
Time the 5VSB output voltage stays within regulation after loss of AC.
T vout_holdup
Vout
T sb_on_delay
PWOK
T
AC_on_delay
T pwok_on
T pwok_holdup
T pwok_off
T pwok_low
T sb_on_delay
5VSB
T sb_vout
T
5VSB
_holdup
PSON
100
10
70
T pwok_on
T pson_on_delay
MIN
5
100
1
MAX
400
50
500
1000
T
T pwok_off pson_pwok
UNITS ms ms ms ms ms ms ms
AC turn on/off cycle
PSON turn on/off cycle
Figure 35. Turn On/Off Timing (Power Supply Signals)
Revision 1.2 Intel order number G34153-003 117
Appendix A: Integration and Usage Tips
Appendix A: Integration and Usage Tips
When adding or removing components or peripherals from the server board, AC power must be removed. With AC power plugged into the server board, 5-V standby is still present even though the server board is powered off.
This server board supports The Intel
®
Xeon
®
Processor E5-2600 product family and E5-2600 v2 product family with a Thermal Design Power (TDP) of up to and including 135 Watts (TDP of up to 150W only for Workstation board). Previous generations of Intel
®
Xeon
®
processors are not supported.
Processors must be installed in order. CPU 1 must be populated for operating the server board.
On the back edge of the server board are eight diagnostic LEDs that display a sequence of amber POST codes during the boot process. If the server board hangs during POST, LEDs display the last POST event run before the hang.
This server board only supports registered DDR3 DIMMs (RDIMMs) and unbuffered DDR3
DIMMs (UDIMMs). Mixing of RDIMMs and UDIMMs is not supported.
For the best performance, the number of DDR3 DIMMs installed should be balanced across both processor sockets and memory channels. For example, a two-DIMM configuration performs better than a one-DIMM configuration. In a two-DIMM configuration, DIMMs should be installed in
DIMM sockets A1 and D1.
The Intel
®
Remote Management Module 4 (Intel
® previous versions of the Intel
®
RMM4) connector is not compatible with any
Remote Management Module (Product Order Code
– AXXRMM,
AXXRMM2, and AXXRMM3).
Clear the CMOS with AC power cord plugged. Removing the AC power before performing the
CMOS clear operation causes the system to automatically power up and immediately power down after the CMOS clear procedure is followed and AC power is re-applied. If this happens, remove the AC power cord, wait 30 seconds, and then reconnect the AC power cord. Power up the system and proceed to the <F2> BIOS Setup utility to reset the desired settings.
Normal Integrated BMC functionality is disabled with the BMC Force Update jumper set to the
“enabled” position (pins 2-3). The server should never be run with the BMC Force Update jumper set in this position and should only be used when the standard firmware update process fails.
This jumper should remain in the default (disabled) position (pins 1- 2) when the server is running normally.
When performing a normal BIOS update procedure, the BIOS recovery jumper must be set to its default position (pins 1-2).
Intel order number G34153-003 Revision 1.2
Appendix B: BMC Sensor Tables
Appendix B: BMC Sensor Tables
This appendix lists the sensor identification numbers and information about the sensor type, name, supported thresholds, assertion and de-assertion information, and a brief description of the sensor purpose. See the Intelligent Platform Management Interface Specification, Version 2.0 for sensor and event/reading-type table information.
Sensor Type Codes
Sensor table given below lists the sensor identification numbers and information regarding the sensor type, name, supported thresholds, assertion and de-assertion information, and a brief description of the sensor purpose. Refer to the Intelligent Platform Management Interface Specification, Version 2.0 for sensor and event/reading-type table information.
Sensor Type
The sensor type references the values in the Sensor Type Codes table in the Intelligent Platform
Management Interface Specification Second Generation v2.0. It provides a context to interpret the sensor.
Event/Reading Type
The event/reading type references values from the Event/Reading Type Code Ranges and the
Generic Event/Reading Type Code tables in the Intelligent Platform Management Interface
Specification Second Generation v2.0. Digital sensors are specific type of discrete sensors that only have two states.
Event Thresholds/Triggers
The following event thresholds are supported for threshold type sensors:
-
[u,l][nr,c,nc] upper non-recoverable, upper critical, upper non-critical, lower non-recoverable, lower critical, lower non-critical uc, lc upper critical, lower critical
Event triggers are supported event-generating offsets for discrete type sensors. The offsets can be found in the Generic Event/Reading Type Code or Sensor Type Code tables in the Intelligent
Platform Management Interface Specification Second Generation v2.0, depending on whether the sensor event/reading type is generic or a sensor-specific response.
Assertion/Deassertion
Assertion and de-assertion indicators reveal the type of events this sensor generates:
- As: Assertion
-
De: De-assertion
Readable Value/Offsets
- Readable value indicates the type of value returned for threshold and other nondiscrete type sensors.
-
Readable offsets indicate the offsets for discrete sensors that are readable by means of the Get Sensor Reading command. Unless otherwise indicated, event triggers are readable. Readable offsets consist of the reading type offsets that do not generate events.
Event Data
Event data is the data that is included in an event message generated by the associated sensor.
For threshold-based sensors, these abbreviations are used:
- R: Reading value
-
T: Threshold value
Rearm Sensors
Revision 1.2 Intel order number G34153-003 119
Appendix B: BMC Sensor Tables
The rearm is a request for the event status for a sensor to be rechecked and updated upon a transition between good and bad states. Rearming the sensors can be done manually or automatically. This column indicates the type supported by the sensor. The following abbreviations are used in the comment column to describe a sensor:
-
A: Auto-rearm
-
M: Manual rearm
-
I: Rearm by init agent
Default Hysteresis
The hysteresis setting applies to all thresholds of the sensor. This column provides the count of hysteresis for the sensor, which can be 1 or 2 (positive or negative hysteresis).
Criticality
Criticality is a classification of the severity and nature of the condition. It also controls the behavior of the front panel status LED.
Standby
Some sensors operate on standby power. These sensors may be accessed and/or generate events when the main (system) power is off, but AC power is present.
120 Intel order number G34153-003 Revision 1.2
Appendix B: BMC Sensor Tables
Note: All sensors listed below may not be present on all platforms. Please check platform EPS section for platform applicability and platform chassis section for chassis specific sensors. Redundancy sensors will be only present on systems with appropriate hardware to support redundancy (for instance, fan or power supply).
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Power Unit Status
(Pwr Unit Status)
01h All
Table 71. Integrated BMC Core Sensors
Sensor Type Event/Reading
Type
Power Unit
09h
Sensor
Specific
6Fh
Event Offset Triggers
00 - Power down
02 - 240 VA power down
04 - A/C lost
05 - Soft power control failure
06 - Power unit failure
00 - Fully Redundant
Contrib. To
System
Status
OK
Assert/Deassert
Readable
Value/
Offsets
Fatal
OK
Fatal
OK
As and
De
–
Event
Data
Trig
Offset
Rearm Standby
A X
01 - Redundancy lost Degraded
Power Unit
Redundancy
1
(Pwr
Unit Redund)
02h
Chassisspecific
Power Unit
09h
Generic
0Bh
02 - Redundancy degraded
03 - Non-redundant: sufficient resources.
Transition from full redundant state.
04
– Non-redundant: sufficient resources.
Transition from insufficient state.
05 - Non-redundant: insufficient resources
06
– Redundant: degraded from fully redundant state.
Degraded
Degraded
Degraded
Fatal
Degraded
As and
De
–
Trig
Offset
M X
Revision 1.2 Intel order number G34153-003 121
Appendix B: BMC Sensor Tables
Full Sensor Name
(Sensor name in SDR)
IPMI Watchdog
(IPMI Watchdog)
Physical Security
(Physical Scrty)
FP Interrupt
(FP NMI Diag Int)
SMI Timeout
(SMI Timeout)
System Event Log
(System Event
Log)
System Event
(System Event)
Button Sensor
(Button)
BMC Watchdog
Sensor
#
03h
08h
09h
0Ah
Platform
Applicability
All
All
All
All
Sensor Type Event/Reading
Type
Watchdog 2
23h
Sensor
Specific
6Fh
Event Offset Triggers
07
– Redundant:
Transition from nonredundant state.
00 - Timer expired, status only
01 - Hard reset
02 - Power down
03 - Power cycle
08 - Timer interrupt
00 - Chassis intrusion
04 - LAN leash lost
Contrib. To
System
Status
Degraded
Assert/Deassert
Readable
Value/
Offsets
OK
Degraded
OK
As
As and
De
–
–
04h
Chassis
Intrusion is chassisspecific
05h
06h
07h
Chassis specific
All
All
Physical
Security
05h
Critical
Interrupt
13h
SMI Timeout
F3h
Event Logging
Disabled
10h
System Event
12h
Button/Switch
14h
Mgmt System
Health
28h
Sensor
Specific
6Fh
Sensor
Specific
6Fh
Digital
Discrete
03h
Sensor
Specific
6Fh
Sensor
Specific
6Fh
Sensor
Specific
6Fh
Digital
Discrete
03h
00 - Front panel
NMI/diagnostic interrupt
01
– State asserted
02 - Undetermined system H/W failure
04
00
02
– PEF action
– Power Button
– Reset Button
01
02 - Log area reset/cleared
– State Asserted
OK
Fatal
OK
Fatal
OK
OK
Degraded
As
As and
De
As
As and
De
As
AS
As
–
–
–
-
_
–
Event
Data
Rearm Standby
Trig
Offset
Trig
Offset
Trig
Offset
Trig
Offset
Trig
Offset
Trig
Offset
Trig
Offset
Trig
Offset
A
A
A
A
A
A
A
A
X
X
–
–
X
X
X
-
122 Intel order number G34153-003 Revision 1.2
Appendix B: BMC Sensor Tables
Full Sensor Name
(Sensor name in SDR)
Voltage Regulator
Watchdog
(VR Watchdog)
Sensor
#
Platform
Applicability
0Bh All
Fan Redundancy
1
(Fan Redundancy)
0Ch
SSB Thermal Trip
(SSB Therm Trip)
0Dh
IO Module
Presence
(IO Mod Presence)
SAS Module
Presence
(SAS Mod
Presence)
0Eh
0Fh
Chassisspecific
All
Sensor Type Event/Reading
Type
Voltage
02h
Fan
04h
Digital
Discrete
03h
Generic
0Bh
Event Offset Triggers
01
– State Asserted
Contrib. To
System
Status
Assert/Deassert
Fatal
As and
De
Readable
Value/
Offsets
–
00 - Fully redundant
OK
01 - Redundancy lost
Degraded
02 - Redundancy degraded
Degraded
03 - Non-redundant:
Sufficient resources.
Transition from redundant
04 - Non-redundant:
Sufficient resources.
Transition from insufficient.
Degraded
Degraded
05 - Non-redundant: insufficient resources.
06
– Non-Redundant: degraded from fully redundant.
07 - Redundant degraded from nonredundant
Non-Fatal
Degraded
Degraded
As and
De
–
Temperature
01h
Platformspecific
Module/Board
15h
Platformspecific
Module/Board
15h
Digital
Discrete
03h
Digital
Discrete
08h
Digital
Discrete
08h
01
01
01
– State Asserted
– Inserted/Present
– Inserted/Present
Fatal
OK
OK
As and
De
As and
De
As and
De
–
–
–
Event
Data
Trig
Offset
Trig
Offset
Trig
Offset
Trig
Offset
Trig
Offset
Rearm Standby
M
A
M
M
M
X
–
X
-
X
Revision 1.2 Intel order number G34153-003 123
Appendix B: BMC Sensor Tables
Full Sensor Name
(Sensor name in SDR)
BMC Firmware
Health
(BMC FW Health)
Sensor
#
10h
System Airflow
(System Airflow)
11h
FW Update Status 12h
Platform
Applicability
All
All
All
Sensor Type Event/Reading
Type
Event Offset Triggers
Mgmt Health
28h
Other Units
0Bh
Version
Change 2Bh
Sensor
Specific
6Fh
Threshold
01h
OEM defined x70h
04
– Sensor Failure
–
00hUpdate started
01hUpdate completed successfully.
Contrib. To
System
Status
Degraded
Assert/Deassert
As
Readable
Value/
Offsets
-
–
OK
–
As
Analog
_
02hUpdate failure
IO Module2
Presence
(IO Mod2
Presence)
Baseboard
Temperature 5
(Platform Specific)
13h
14h
Platformspecific
Module/Board
15h
Platformspecific
Temperature
01h
Digital
Discrete
08h
Threshold
01h
01
– Inserted/Present
[u,l] [c,nc]
Baseboard
Temperature 6
(Platform Specific)
IO Module2
Temperature
(I/O Mod2 Temp)
PCI Riser 3
Temperature
(PCI Riser 5 Temp)
15h
16h
17h
Platformspecific
Platformspecific
Platformspecific
Temperature
01h
Temperature
01h
Temperature
01h
Threshold
01h
Threshold
01h
Threshold
01h
[u,l] [c,nc]
[u,l] [c,nc]
[u,l] [c,nc]
OK nc =
Degraded c = Nonfatal nc =
Degraded c = Nonfatal nc =
Degraded c = Nonfatal nc =
Degraded c = Nonfatal
As and
De
As and
De
As and
De
As and
De
As and
De
–
Analog
Analog
Analog
Analog
Event
Data
Rearm Standby
Trig
Offset
–
Trig
Offset
Trig
Offset
R, T
R, T
R, T
R, T
A
–
A
M
A
A
A
A
X
–
_
-
X
X
X
X
124 Intel order number G34153-003 Revision 1.2
Appendix B: BMC Sensor Tables
Full Sensor Name
(Sensor name in SDR)
PCI Riser 4
Temperature
(PCI Riser 4 Temp)
Sensor
#
Platform
Applicability
18h
Platformspecific
Sensor Type
Temperature
01h
Event/Reading
Type
Threshold
01h
Event Offset Triggers
[u,l] [c,nc]
Baseboard +1.05V
Processor3 Vccp
(BB +1.05Vccp P3)
19h
Baseboard +1.05V
Processor4 Vccp
(BB +1.05Vccp P4)
1Ah
Platformspecific
Baseboard
Temperature 1
(Platform Specific)
20h
Front Panel
Temperature
(Front Panel Temp)
21h
SSB Temperature
(SSB Temp)
22h
Baseboard
Temperature 2
(Platform Specific)
23h
Baseboard
Temperature 3
(Platform Specific)
24h
Platformspecific
Platformspecific
All
All
Platformspecific
Platformspecific
Voltage
02h
Voltage
02h
Temperature
01h
Temperature
01h
Temperature
01h
Temperature
01h
Temperature
01h
Threshold
01h
Threshold
01h
Threshold
01h
Threshold
01h
Threshold
01h
Threshold
01h
Threshold
01h
[u,l] [c,nc]
[u,l] [c,nc]
[u,l] [c,nc]
[u,l] [c,nc]
[u,l] [c,nc]
[u,l] [c,nc]
[u,l] [c,nc] nc =
Degraded c = Nonfatal nc =
Degraded c = Nonfatal nc =
Degraded c = Nonfatal nc =
Degraded c = Nonfatal
Contrib. To
System
Status nc =
Degraded c = Nonfatal nc =
Degraded c = Nonfatal nc =
Degraded c = Nonfatal nc =
Degraded c = Nonfatal
Assert/Deassert
As and
De
As and
De
As and
De
As and
De
As and
De
As and
De
As and
De
As and
De
Readable
Value/
Offsets
Analog
Analog
Analog
Analog
Analog
Analog
Analog
Analog
Event
Data
R, T
R, T
R, T
R, T
R, T
R, T
R, T
R, T
Rearm Standby
A
A
A
A
A
A
A
A
X
–
–
X
X
X
X
X
Revision 1.2 Intel order number G34153-003 125
Appendix B: BMC Sensor Tables
Full Sensor Name
(Sensor name in SDR)
Baseboard
Temperature 4
(Platform Specific)
Sensor
#
Platform
Applicability
25h
Platformspecific
Sensor Type
Temperature
01h
Event/Reading
Type
Threshold
01h
Event Offset Triggers
[u,l] [c,nc]
IO Module
Temperature
(I/O Mod Temp)
26h
Platformspecific
Temperature
01h
PCI Riser 1
Temperature
(PCI Riser 1 Temp)
27h
Platformspecific
Temperature
01h
IO Riser
Temperature
(IO Riser Temp)
Hot-swap
Backplane 1
Temperature
(HSBP 1 Temp)
Hot-swap
Backplane 2
Temperature
(HSBP 2 Temp)
Hot-swap
Backplane 3
Temperature
(HSBP 3 Temp)
28h
29h
2Ah
2Bh
PCI Riser 2
Temperature
(PCI Riser 2 Temp)
2Ch
Platformspecific
Chassisspecific
Chassisspecific
Chassisspecific
Platformspecific
Temperature
01h
Temperature
01h
Temperature
01h
Temperature
01h
Temperature
01h
Threshold
01h
Threshold
01h
Threshold
01h
Threshold
01h
Threshold
01h
Threshold
01h
Threshold
01h
[u,l] [c,nc]
[u,l] [c,nc]
[u,l] [c,nc]
[u,l] [c,nc]
[u,l] [c,nc]
[u,l] [c,nc]
[u,l] [c,nc] nc =
Degraded c = Nonfatal nc =
Degraded c = Nonfatal nc =
Degraded c = Nonfatal
Contrib. To
System
Status nc =
Degraded c = Nonfatal nc =
Degraded c = Nonfatal nc =
Degraded c = Nonfatal nc =
Degraded c = Nonfatal nc =
Degraded c = Nonfatal
Assert/Deassert
As and
De
As and
De
As and
De
As and
De
As and
De
As and
De
As and
De
As and
De
Readable
Value/
Offsets
Analog
Analog
Analog
Analog
Analog
Analog
Analog
Analog
Event
Data
Rearm Standby
R, T
R, T
R, T
R, T
R, T
R, T
R, T
R, T
A
A
A
A
A
A
A
A
X
X
X
X
X
X
X
X
126 Intel order number G34153-003 Revision 1.2
Appendix B: BMC Sensor Tables
Full Sensor Name
(Sensor name in SDR)
SAS Module
Temperature
(SAS Mod Temp)
Sensor
#
Platform
Applicability
2Dh
Platformspecific
Sensor Type
Temperature
01h
Event/Reading
Type
Threshold
01h
Event Offset Triggers
[u,l] [c,nc]
Chassis and
Platform
Specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
Exit Air
Temperature
(Exit Air Temp)
2Eh
Network Interface
Controller
Temperature
(LAN NIC Temp)
Fan Tachometer
Sensors
(Chassis specific sensor names)
Fan Present
Sensors
(Fan x Present)
2Fh
30h
–
3Fh
40h
–
4Fh
All
Chassis and
Platform
Specific
Chassis and
Platform
Specific
Temperature
01h
Fan
04h
Fan
04h
Threshold
01h
Threshold
01h
Generic
08h
[u,l] [c,nc]
[l] [c,nc]
01 - Device inserted
Power Supply 1
Status
(PS1 Status)
Power Supply 2
Status
(PS2 Status)
50h
51h
Chassisspecific
Power Supply
08h
Chassisspecific
Power Supply
08h
Sensor
Specific
6Fh
Sensor
Specific
6Fh
Contrib. To
System
Status nc =
Degraded c = Nonfatal nc =
Degraded c = Nonfatal nc =
Degraded c = Nonfatal nc =
Degraded c = Nonfatal
2
Assert/Deassert
As and
De
As and
De
As and
De
As and
De
Readable
Value/
Offsets
Analog
Analog
Analog
Analog
OK
00 - Presence
01 - Failure Degraded
02
– Predictive Failure Degraded
03 - A/C lost
06
– Configuration error
OK
Degraded
OK
00 - Presence OK
01 - Failure Degraded
02
– Predictive Failure Degraded
Degraded 03 - A/C lost
06
– Configuration error
OK
As and
De
As and
De
As and
De
-
–
–
Event
Data
R, T
R, T
R, T
R, T
Triggered
Offset
Auto
Trig
Offset
Trig
Offset
Rearm Standby
A
A
A
M
A
A
X
X
X
-
-
X
X
Revision 1.2 Intel order number G34153-003 127
Appendix B: BMC Sensor Tables
Full Sensor Name
(Sensor name in SDR)
Power Supply 1
AC Power Input
(PS1 Power In)
Sensor
#
Platform
Applicability
54h
Chassisspecific
Power Supply 2
AC Power Input
(PS2 Power In)
55h
Power Supply 1
+12V % of
Maximum Current
Output
(PS1 Curr Out %)
Power Supply 2
+12V % of
Maximum Current
Output
(PS2 Curr Out %)
58h
59h
Power Supply 1
Temperature
(PS1 Temperature)
5Ch
Chassisspecific
Chassisspecific
Chassisspecific
Chassisspecific
Power Supply 2
Temperature
(PS2 Temperature)
5Dh
Chassisspecific
Hard Disk Drive 16
- 24 Status
(HDD 16 - 24
Status)
60h
–
68h
Chassisspecific
Sensor Type Event/Reading
Type
Event Offset Triggers
Other Units
0Bh
Other Units
0Bh
Current
03h
Threshold
01h
Threshold
01h
Threshold
01h
[u] [c,nc]
[u] [c,nc]
[u] [c,nc]
Contrib. To
System
Status nc =
Degraded c = Nonfatal nc =
Degraded c = Nonfatal
Assert/Deassert
Readable
Value/
Offsets
As and
De
As and
De
Analog
Analog nc =
Degraded c = Nonfatal
As and
De
Analog
Current
03h
Temperature
01h
Temperature
Drive Slot
0Dh
Threshold
01h
Threshold
01h
Threshold
01h
Sensor
Specific
6Fh
[u] [c,nc] nc =
Degraded c = Nonfatal
[u] [c,nc]
[u] [c,nc]
00 - Drive Presence nc =
Degraded c = Nonfatal nc =
Degraded c = Nonfatal
OK
01- Drive Fault Degraded
07 - Rebuild/Remap in progress
Degraded
As and
De
As and
De
As and
De
As and
De
Analog
Analog
Analog
–
Event
Data
Rearm Standby
R, T
R, T
R, T
R, T
R, T
R, T
Trig
Offset
A
A
A
A
A
A
A
X
X
X
X
X
X
X
128 Intel order number G34153-003 Revision 1.2
Appendix B: BMC Sensor Tables
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
69h
-
6Bh
Chassisspecific
Sensor Type Event/Reading
Type
Event Offset Triggers
Microcontroller
16h
Discrete 0Ah
04- transition to Off
Line
Processor 1 Status
(P1 Status)
Processor 2 Status
(P2 Status)
Processor 3 Status
(P3 Status)
Processor 4 Status
(P4 Status)
70h
71h
72h
73h
All
All
Platformspecific
Platformspecific
Processor
07h
Processor
07h
Processor
07h
Processor
07h
Sensor
Specific
6Fh
Sensor
Specific
6Fh
Sensor
Specific
6Fh
Sensor
Specific
6Fh
01 - Thermal trip
07 - Presence
01 - Thermal trip
07 - Presence
01 - Thermal trip
07 - Presence
01 - Thermal trip
07 - Presence
Processor 1
Thermal Margin
(P1 Therm Margin)
Processor 2
Thermal Margin
(P2 Therm Margin)
Processor 3
Thermal Margin
(P3 Therm Margin)
Processor 4
Thermal Margin
(P4 Therm Margin)
Processor 1
Thermal
Control %
(P1 Therm Ctrl %)
74h
75h
76h
77h
78h
All
All
Platformspecific
Platformspecific
All
Temperature
01h
Temperature
01h
Temperature
01h
Temperature
01h
Temperature
01h
Threshold
01h
Threshold
01h
Threshold
01h
Threshold
01h
Threshold
01h
-
-
-
-
[u] [c,nc]
-
-
-
-
Contrib. To
System
Status
Assert/Deassert
Readable
Value/
Offsets
Degraded
Fatal
OK
Fatal
OK
Fatal
OK
Fatal
OK nc =
Degraded c = Nonfatal
As and
De
As and
De
As and
De
As and
De
-
-
-
-
As and
De
–
–
–
–
–
Analog
Analog
Analog
Analog
Analog
Event
Data
Trig
Offset
Trig
Offset
Trig
Offset
Trig
Offset
Trig
Offset
R, T
R, T
R, T
R, T
Trig
Offset
Rearm Standby
M
M
M
M
A
A
A
A
A
X
X
X
X
X
–
–
–
–
–
Revision 1.2 Intel order number G34153-003 129
Appendix B: BMC Sensor Tables
Full Sensor Name
(Sensor name in SDR)
Processor 2
Thermal
Control %
(P2 Therm Ctrl %)
Processor 3
Thermal
Control %
(P3 Therm Ctrl %)
Processor 4
Thermal
Control %
(P4 Therm Ctrl %)
Processor 1 ERR2
Timeout
(P1 ERR2)
Processor 2 ERR2
Timeout
(P2 ERR2)
Processor 3 ERR2
Timeout
(P3 ERR2)
Processor 4 ERR2
Timeout
(P4 ERR2)
Sensor
#
Platform
Applicability
79h
7Ah
7Bh
7Ch
7Dh
7Eh
7Fh
All
Platformspecific
Platformspecific
All
All
Platformspecific
Platformspecific
Sensor Type
Temperature
01h
Temperature
01h
Temperature
01h
Processor
07h
Processor
07h
Processor
07h
Processor
07h
Event/Reading
Type
Threshold
01h
Threshold
01h
Threshold
01h
Catastrophic Error
(CATERR)
80h All
Processor
07h
Digital
Discrete
03h
Digital
Discrete
03h
Digital
Discrete
03h
Digital
Discrete
03h
Digital
Discrete
03h
Processor1 MSID
Mismatch
(P1 MSID
Mismatch)
81h All
Processor
07h
Digital
Discrete
03h
Event Offset Triggers
[u] [c,nc]
[u] [c,nc]
[u] [c,nc]
01
– State Asserted
01
– State Asserted
01
– State Asserted
01
– State Asserted
01
– State Asserted
01
– State Asserted
Contrib. To
System
Status nc =
Degraded c = Nonfatal nc =
Degraded c = Nonfatal nc =
Degraded c = Nonfatal
Assert/Deassert
Readable
Value/
Offsets
As and
De
As and
De
As and
De
Analog
Analog
Analog fatal fatal fatal fatal fatal fatal
As and
De
As and
De
As and
De
As and
De
As and
De
As and
De
–
–
–
–
–
–
Event
Data
Rearm Standby
Trig
Offset
Trig
Offset
Trig
Offset
Trig
Offset
Trig
Offset
Trig
Offset
Trig
Offset
Trig
Offset
Trig
Offset
A
A
A
A
A
A
A
M
M
–
–
–
–
–
–
–
–
–
130 Intel order number G34153-003 Revision 1.2
Appendix B: BMC Sensor Tables
Full Sensor Name
(Sensor name in SDR)
Processor
Population Fault
(CPU Missing)
Processor 1 DTS
Thermal Margin
(P1 DTS Therm
Mgn)
Processor 2 DTS
Thermal Margin
(P2 DTS Therm
Mgn)
Processor 3 DTS
Thermal Margin
(P3 DTS Therm
Mgn)
Processor 4 DTS
Thermal Margin
(P4 DTS Therm
Mgn)
Processor2 MSID
Mismatch
(P2 MSID
Mismatch)
Processor 1 VRD
Temperature
(P1 VRD Hot)
Processor 2 VRD
Temperature
(P2 VRD Hot)
Sensor
#
Platform
Applicability
82h
83h
84h
85h
86h
87h
90h
91h
All
All
All
All
All
All
All
All
Processor 3 VRD
Temperature
(P3 VRD Hot)
92h All
Sensor Type Event/Reading
Type
Processor
07h
Temperature
01h
Temperature
01h
Temperature
01h
Temperature
01h
Processor
07h
Temperature
01h
Temperature
01h
Temperature
01h
Digital
Discrete
03h
Threshold
01h
Threshold
01h
Threshold
01h
Threshold
01h
Digital
Discrete
03h
Digital
Discrete
05h
Digital
Discrete
05h
Digital
Discrete
05h
Event Offset Triggers
01
– State Asserted
-
-
-
-
01
– State Asserted
01 - Limit exceeded
Contrib. To
System
Status
Assert/Deassert
Fatal
As and
De
Readable
Value/
Offsets
–
-
-
-
- fatal
01 - Limit exceeded Non-fatal
01 - Limit exceeded Non-fatal
Fatal
-
-
-
-
As and
De
As and
De
As and
De
As and
De
Analog
Analog
Analog
Analog
–
–
–
–
Event
Data
Trig
Offset
R, T
R, T
R, T
R, T
Trig
Offset
Trig
Offset
Trig
Offset
Trig
Offset
Rearm Standby
M
A
A
A
A
M
M
M
M
–
–
–
–
–
–
–
–
–
Revision 1.2 Intel order number G34153-003 131
Appendix B: BMC Sensor Tables
Full Sensor Name
(Sensor name in SDR)
Processor 4 VRD
Temperature
(P4 VRD Hot)
Processor 1
Memory VRD Hot
0-1
(P1 Mem01 VRD
Hot)
Processor 1
Memory VRD Hot
2-3
(P1 Mem23 VRD
Hot)
Processor 2
Memory VRD Hot
0-1
(P2 Mem01 VRD
Hot)
Processor 2
Memory VRD Hot
2-3
(P2 Mem23 VRD
Hot)
Processor 3
Memory VRD Hot
0-1
(P3 Mem01 VRD
Hot)
Processor 3
Memory VRD Hot
2-3
(P4 Mem23 VRD
Hot)
Processor 4
Memory VRD Hot
0-1
(P4 Mem01 VRD
Hot)
Sensor
#
Platform
Applicability
93h
94h
95h
96h
97h
98h
99h
9Ah
All
All
All
All
All
All
All
All
Sensor Type
Temperature
01h
Temperature
01h
Temperature
01h
Temperature
01h
Temperature
01h
Temperature
01h
Temperature
01h
Temperature
01h
Event/Reading
Type
Digital
Discrete
05h
Digital
Discrete
05h
Digital
Discrete
05h
Digital
Discrete
05h
Digital
Discrete
05h
Digital
Discrete
05h
Digital
Discrete
05h
Digital
Discrete
05h
Event Offset Triggers
01 - Limit exceeded
Contrib. To
System
Status
Assert/Deassert
Readable
Value/
Offsets
Fatal
As and
De
–
01 - Limit exceeded Non-fatal
01 - Limit exceeded Non-fatal
01 - Limit exceeded Non-fatal
01 - Limit exceeded Non-fatal
01 - Limit exceeded Non-fatal
01 - Limit exceeded Non-fatal
01 - Limit exceeded Non-fatal
As and
De
As and
De
As and
De
As and
De
As and
De
As and
De
As and
De
–
–
–
–
–
–
–
Event
Data
Rearm Standby
Trig
Offset
Trig
Offset
Trig
Offset
Trig
Offset
Trig
Offset
Trig
Offset
Trig
Offset
Trig
Offset
M
A
A
A
A
A
A
A
–
–
–
–
–
–
–
–
132 Intel order number G34153-003 Revision 1.2
Appendix B: BMC Sensor Tables
Full Sensor Name
(Sensor name in SDR)
Processor 4
Memory VRD Hot
2-3
(P4 Mem23 VRD
Hot)
Power Supply 1
Fan Tachometer 1
(PS1 Fan Tach 1)
Power Supply 1
Fan Tachometer 2
(PS1 Fan Tach 2)
Power Supply 2
Fan Tachometer 1
(PS2 Fan Tach 1)
Power Supply 2
Fan Tachometer 2
(PS2 Fan Tach 2)
Processor 1 DIMM
Aggregate Thermal
Margin 1
(P1 DIMM Thrm
Mrgn1)
Processor 1 DIMM
Aggregate Thermal
Margin 2
(P1 DIMM Thrm
Mrgn2)
Processor 2 DIMM
Aggregate Thermal
Margin 1
(P2 DIMM Thrm
Mrgn1)
Processor 2 DIMM
Aggregate Thermal
Margin 2
(P2 DIMM Thrm
Mrgn2)
Sensor
#
Platform
Applicability
9Bh
A0h
A1h
A4h
A5h
B0h
B1h
B2h
B3h
All
Chassisspecific
Chassisspecific
Chassisspecific
Chassisspecific
All
All
All
All
Sensor Type
Temperature
01h
Fan
04h
Fan
04h
Fan
04h
Fan
04h
Temperature
01h
Temperature
01h
Temperature
01h
Temperature
01h
Event/Reading
Type
Digital
Discrete
05h
Generic digital
Threshold
01h
Threshold
01h
Threshold
01h
Threshold
01h
– discrete
Generic
– digital discrete
Generic
– digital discrete
Generic
– digital discrete
Event Offset Triggers
01 - Limit exceeded
[u,l] [c,nc]
[u,l] [c,nc]
[u,l] [c,nc]
[u,l] [c,nc]
Contrib. To
System
Status
Non-fatal
01
– State Asserted
Non-fatal
01
– State Asserted
Non-fatal
01
– State Asserted
Non-fatal
01
– State Asserted
Non-fatal nc =
Degraded c = Nonfatal nc =
Degraded c = Nonfatal nc =
Degraded c = Nonfatal nc =
Degraded c = Nonfatal
Assert/Deassert
As and
De
As and
De
As and
De
As and
De
As and
De
As and
De
As and
De
As and
De
As and
De
Readable
Value/
Offsets
–
-
-
-
-
Analog
Analog
Analog
Analog
Event
Data
Trig
Offset
Trig
Offset
Trig
Offset
Trig
Offset
Trig
Offset
R, T
R, T
R, T
R, T
Rearm Standby
A
M
M
M
M
A
A
A
A
–
-
-
-
-
–
–
–
–
Revision 1.2 Intel order number G34153-003 133
Appendix B: BMC Sensor Tables
Full Sensor Name
(Sensor name in SDR)
Processor 3 DIMM
Aggregate Thermal
Margin 1
(P3 DIMM Thrm
Mrgn1)
Processor 3 DIMM
Aggregate Thermal
Margin 2
(P3 DIMM Thrm
Mrgn2)
Processor 4 DIMM
Aggregate Thermal
Margin 1
(P4 DIMM Thrm
Mrgn1)
Processor 4 DIMM
Aggregate Thermal
Margin 2
(P4 DIMM Thrm
Mrgn2)
Fan Tachometer
Sensors
(Chassis specific sensor names)
Processor 1 DIMM
Thermal Trip
(P1 Mem Thrm
Trip)
Processor 2 DIMM
Thermal Trip
(P2 Mem Thrm
Trip)
Processor 3 DIMM
Sensor
#
Platform
Applicability
B4h
B5h
B6h
B7h
BAh
–
BFh
C0h
C1h
Platform
Specific
Platform
Specific
Platform
Specific
Platform
Specific
Chassis and
Platform
Specific
All
All
Thermal Trip
(P3 Mem Thrm
Trip)
C2h All
Sensor Type
Temperature
01h
Temperature
01h
Temperature
01h
Temperature
01h
Fan
04h
Memory
0Ch
Memory
0Ch
Memory
0Ch
Event/Reading
Type
Threshold
01h
Threshold
01h
Threshold
01h
Threshold
01h
Threshold
01h
Digital
Discrete
03h
Digital
Discrete
03h
Digital
Discrete
03h
Event Offset Triggers
[u,l] [c,nc]
[u,l] [c,nc]
[u,l] [c,nc]
[u,l] [c,nc]
[l] [c,nc]
0A- Critical overtemperature
0A- Critical overtemperature
0A- Critical overtemperature
Contrib. To
System
Status nc =
Degraded c = Nonfatal nc =
Degraded c = Nonfatal nc =
Degraded c = Nonfatal nc =
Degraded c = Nonfatal nc =
Degraded c = Nonfatal
2
Assert/Deassert
As and
De
As and
De
As and
De
As and
De
As and
De
Readable
Value/
Offsets
Analog
Analog
Analog
Analog
Analog
Fatal
Fatal
Fatal
As and
De
As and
De
As and
De
–
–
–
Event
Data
Rearm Standby
R, T
R, T
R, T
R, T
R, T
Trig
Offset
Trig
Offset
Trig
Offset
A
A
A
A
M
M
M
M
–
–
–
–
-
-
-
X
134 Intel order number G34153-003 Revision 1.2
Appendix B: BMC Sensor Tables
Full Sensor Name
(Sensor name in SDR)
Processor 4 DIMM
Sensor
#
Platform
Applicability
Sensor Type Event/Reading
Type
Event Offset Triggers
Thermal Trip
(P4 Mem Thrm
Trip)
Global Aggregate
Temperature
Margin 1
(Agg Therm Mrgn
1)
Global Aggregate
Temperature
Margin 2
(Agg Therm Mrgn
2)
Global Aggregate
Temperature
Margin 3
(Agg Therm Mrgn
3)
Global Aggregate
Temperature
Margin 4
(Agg Therm Mrgn
4)
Global Aggregate
Temperature
Margin 5
(Agg Therm Mrgn
5)
Global Aggregate
Temperature
Margin 6
(Agg Therm Mrgn
6)
Global Aggregate
Temperature
Margin 7
(Agg Therm Mrgn
7)
C3h
C8h
C9h
CAh
CBh
CCh
CDh
CEh
All
Platform
Specific
Platform
Specific
Platform
Specific
Platform
Specific
Platform
Specific
Platform
Specific
Platform
Specific
Memory
0Ch
Temperature
01h
Temperature
01h
Temperature
01h
Temperature
01h
Temperature
01h
Temperature
01h
Temperature
01h
Digital
Discrete
03h
Threshold
01h
Threshold
01h
Threshold
01h
Threshold
01h
Threshold
01h
Threshold
01h
Threshold
01h
0A- Critical overtemperature
-
-
-
-
-
-
-
Contrib. To
System
Status
Assert/Deassert
Readable
Value/
Offsets
Fatal
As and
De
–
Event
Data
Trig
Offset
Rearm Standby
M X
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Analog
Analog
Analog
Analog
Analog
Analog
Analog
R, T
R, T
R, T
R, T
R, T
R, T
R, T
A
A
A
A
A
A
A
–
–
–
–
–
–
–
Revision 1.2 Intel order number G34153-003 135
Appendix B: BMC Sensor Tables
Full Sensor Name
(Sensor name in SDR)
Global Aggregate
Temperature
Margin 8
(Agg Therm Mrgn
8)
Sensor
#
Platform
Applicability
CFh
Platform
Specific
Sensor Type
Temperature
01h
Event/Reading
Type
Threshold
01h
Event Offset Triggers
-
Contrib. To
System
Status
Assert/Deassert
Readable
Value/
Offsets
- - Analog
Baseboard +12V
(BB +12.0V)
D0h
Baseboard +5V
(BB +5.0V)
D1h
Baseboard +3.3V
(BB +3.3V)
D2h
Baseboard +5V
Stand-by
(BB +5.0V STBY)
D3h
Baseboard +3.3V
Auxiliary
(BB +3.3V AUX)
D4h
Baseboard +1.05V
Processor1 Vccp
(BB +1.05Vccp P1)
D6h
Baseboard +1.05V
Processor2 Vccp
(BB +1.05Vccp P2)
D7h
All
All
All
All
All
All
All
Voltage
02h
Voltage
02h
Voltage
02h
Voltage
02h
Voltage
02h
Voltage
02h
Voltage
02h
Threshold
01h
Threshold
01h
Threshold
01h
Threshold
01h
Threshold
01h
Threshold
01h
Threshold
01h
[u,l] [c,nc]
[u,l] [c,nc]
[u,l] [c,nc]
[u,l] [c,nc]
[u,l] [c,nc]
[u,l] [c,nc]
[u,l] [c,nc] nc =
Degraded c = Nonfatal nc =
Degraded c = Nonfatal nc =
Degraded c = Nonfatal nc =
Degraded c = Nonfatal nc =
Degraded c = Nonfatal nc =
Degraded c = Nonfatal nc =
Degraded c = Nonfatal
As and
De
Analog
As and
De
Analog
As and
De
Analog
As and
De
Analog
As and
De
Analog
As and
De
Analog
As and
De
Analog
Event
Data
Rearm Standby
R, T
R, T
R, T
R, T
R, T
R, T
R, T
R, T
A
A
A
A
A
A
A
A
–
–
–
–
X
X
–
–
136 Intel order number G34153-003 Revision 1.2
Appendix B: BMC Sensor Tables
Full Sensor Name
(Sensor name in SDR)
Baseboard +1.5V
P1 Memory AB
VDDQ
(BB +1.5 P1MEM
AB)
Baseboard +1.5V
P1 Memory CD
VDDQ
(BB +1.5 P1MEM
CD)
Baseboard +1.5V
P2 Memory AB
VDDQ
(BB +1.5 P2MEM
AB)
Baseboard +1.5V
P2 Memory CD
VDDQ
(BB +1.5 P2MEM
CD)
Sensor
#
Platform
Applicability
D8h
D9h
DAh
DBh
All
All
All
All
Baseboard +1.8V
Aux
(BB +1.8V AUX)
DCh All
Baseboard +1.1V
Stand-by
(BB +1.1V STBY)
DDh
Baseboard CMOS
Battery
(BB +3.3V Vbat)
DEh
All
All
Sensor Type Event/Reading
Type
Event Offset Triggers
Voltage
02h
Threshold
01h
[u,l] [c,nc]
Contrib. To
System
Status nc =
Degraded c = Nonfatal
Assert/Deassert
Readable
Value/
Offsets
As and
De
Analog
Voltage
02h
Voltage
02h
Voltage
02h
Voltage
02h
Voltage
02h
Voltage
02h
Threshold
01h
Threshold
01h
Threshold
01h
Threshold
01h
Threshold
01h
Threshold
01h
[u,l] [c,nc]
[u,l] [c,nc]
[u,l] [c,nc]
[u,l] [c,nc]
[u,l] [c,nc]
[u,l] [c,nc] nc =
Degraded c = Nonfatal nc =
Degraded c = Nonfatal nc =
Degraded c = Nonfatal nc =
Degraded c = Nonfatal nc =
Degraded c = Nonfatal nc =
Degraded c = Nonfatal
As and
De
As and
De
As and
De
As and
De
As and
De
As and
De
Analog
Analog
Analog
Analog
Analog
Analog
Event
Data
R, T
R, T
R, T
R, T
R, T
R, T
R, T
Rearm Standby
A
A
A
A
A
A
A
–
–
–
–
–
–
–
Revision 1.2 Intel order number G34153-003 137
Appendix B: BMC Sensor Tables
Full Sensor Name
(Sensor name in SDR)
Baseboard +1.35V
P1 Low Voltage
Memory AB VDDQ
(BB +1.35 P1LV
AB)
Baseboard +1.35V
P1 Low Voltage
Memory CD VDDQ
Sensor
#
Platform
Applicability
E4h
E5h
All
All
(BB +1.35 P1LV
CD)
Baseboard +1.35V
P2 Low Voltage
Memory AB VDDQ
(BB +1.35 P2LV
AB)
E6h All
Baseboard +1.35V
P2 Low Voltage
Memory CD VDDQ
(BB +1.35 P2LV
CD)
Baseboard +3.3V
Riser 1 Power
Good
(BB +3.3 RSR1
PGD)
Baseboard +3.3V
Riser 2 Power
Good
(BB +3.3 RSR2
PGD)
E7h
EAh
EBh
All
Platform
Specific
Platform
Specific
Hard Disk Drive 1 -
15 Status
F0h
-
Chassisspecific
Sensor Type Event/Reading
Type
Event Offset Triggers
Voltage
02h
Threshold
01h
[u,l] [c,nc]
Contrib. To
System
Status nc =
Degraded c = Nonfatal
Assert/Deassert
Readable
Value/
Offsets
As and
De
Analog
Voltage
02h
Voltage
02h
Voltage
02h
Voltage
02h
Voltage
02h
Drive Slot
0Dh
Threshold
01h
Threshold
01h
Threshold
01h
Threshold
01h
Threshold
01h
Sensor
Specific
[u,l] [c,nc]
[u,l] [c,nc]
[u,l] [c,nc]
[u,l] [c,nc] nc =
Degraded c = Nonfatal nc =
Degraded c = Nonfatal nc =
Degraded c = Nonfatal nc =
Degraded c = Nonfatal
[u,l] [c,nc]
00 - Drive Presence
01- Drive Fault nc =
Degraded c = Nonfatal
OK
Degraded
As and
De
As and
De
As and
De
As and
De
As and
De
As and
De
Analog
Analog
Analog
Analog
Analog
–
Event
Data
Rearm Standby
R, T
R, T
R, T
R, T
R, T
R, T
Trig
Offset
A
A
A
A
A
A
A
–
–
–
–
–
–
X
138 Intel order number G34153-003 Revision 1.2
Appendix B: BMC Sensor Tables
Full Sensor Name
(Sensor name in SDR)
(HDD 1 - 15
Status)
Sensor
#
FEh
Platform
Applicability
Sensor Type Event/Reading
Type
6Fh
Event Offset Triggers Contrib. To
System
Status
07 - Rebuild/Remap in progress
Degraded
Assert/Deassert
Readable
Value/
Offsets
Event
Data
Rearm Standby
Notes:
1. Redundancy sensors will be only present on systems with appropriate hardware to support redundancy (for instance, fan or power supply).
2. This is only applicable when the system doesn't support redundant fans. When fan redundancy is supported, then the contribution to system state is driven by the fan redundancy sensor.
Revision 1.2 Intel order number G34153-003 139
Appendix C: Platform Specific BMC Appendix
Intel
®
Server Board S2600IP
Introduction
This is an addendum document to BMC core EPS. This document describes platform and chassis specific information.
Product ID
Bytes 11:12 (product ID) of Get Device ID command response: 55h 00h
IPMI Channel ID Assignments
The following table provides information on the BMC channel assignments:
Table 72. Intel
®
Server Board S2600IP - BMC Channel Assignments
Channel ID Interface Supports
Sessions
Yes
Yes
Yes
Yes
0
1
2
3
4
5
6
Primary IPMB
LAN 1
LAN 2
(platform specific)
LAN3
1
(Provided by the Intel
®
Dedicated Server Management NIC)
Reserved
USB
Secondary IPMB
7
8
– 0Dh
0Eh
0Fh
Notes:
SMM
Reserved
Self
2
SMS/Receive Message Queue
1. Optional HW supported by the server system.
Yes
No
No
No
–
–
No
2. Refers to the actual channel used to send the request.
ACPI S3 Sleep State Support
Not supported.
Processor Support for Intel
®
Intel ®
Xeon
®
processor E5-2600 and E5-2600 v2 product family up to 135 Watt
Supported Chassis
Intel
®
Server Chassis P4208 (UPL with redundant fan 4U)
Intel
®
Server Chassis P4216 (UPL with redundant fan 4U)
Intel
®
Server Chassis P4224 (UPL with redundant fan 4U)
Intel
®
Server Chassis P4308 (UPL with redundant fan 4U)
140 Intel order number G34153-003 Revision 1.2
Intel
®
Server Chassis P4XXX (UPL with redundant fan 4U)
Intel
®
Server Chassis R2208 (BHP with redundant fan 2U)
Intel
®
Server Chassis R2216 (BHP with redundant fan 2U)
Intel
®
Server Chassis R2224 (BHP with redundant fan 2U)
Intel
®
Server Chassis R2308 (BHP with redundant fan 2U)
Intel
®
Server Chassis R2312 (BHP with redundant fan 2U)
Chassis-specific sensors
Table 73. Intel
®
Server Board S2600IP - Chassis-specific Sensors
Intel
®
Server Chassis
P4208/P4216/P4224/
P4308/P4XXX (UPL with redundant fan
4U)
R2208/R2216/R2224/P
2308/P2312 (BHP with redundant fan 2U)
Fan Tachometer
Sensors
Fan Presence Sensors Physical Security
(Chassis intrusion) sensor
FP Interrupt
(FP NMI Diag Int)
System Fan 1(30h) Fan 1 Present (40h) Physical Scrty (04h) FP NMI Diag Int (05h)
System Fan 2(31h) Fan 2 Present (41h) NA
System Fan 3 (32h) Fan 3 Present (42h) NA
System Fan 4 (33h) Fan 4 Present (43h) NA
System Fan 5 (34h) Fan 5 Present (44h) NA
NA
NA
NA
NA
System Fan 1 (30h) Fan 1 Present (40h) Physical Scrty (04h) FP NMI Diag Int (05h)
System Fan 2 (31h) Fan 2 Present (41h) NA NA
System Fan 3 (32h) Fan 3 Present (42h) NA
System Fan 4 (33h) Fan 4 Present (43h) NA
NA
NA
System Fan 5 (34h) Fan 5 Present (44h) NA
System Fan 6 (35h) Fan 6 Present (45h) NA
NA
NA
Hot-plug fan support
Supported on:
Intel
®
Server Chassis P4208 (UPL with redundant fan 4U)
Intel
®
Server Chassis P4216 (UPL with redundant fan 4U)
Intel
®
Server Chassis P4224 (UPL with redundant fan 4U)
Intel
®
Server Chassis P4308 (UPL with redundant fan 4U)
Intel
®
Server Chassis P4XXX (UPL with redundant fan 4U)
Intel
®
Server Chassis R2208 (BHP with redundant fan 2U)
Intel
®
Server Chassis R2216 (BHP with redundant fan 2U)
Intel
®
Server Chassis R2224 (BHP with redundant fan 2U)
Intel
®
Server Chassis R2308 (BHP with redundant fan 2U)
Intel
®
Server Chassis R2312 (BHP with redundant fan 2U)
Fan redundancy support
Supported on:
Intel
®
Server Chassis P4208 (UPL with redundant fan 4U)
Intel
®
Server Chassis P4216 (UPL with redundant fan 4U)
Intel
®
Server Chassis P4224 (UPL with redundant fan 4U)
Revision 1.2 Intel order number G34153-003 141
Intel
®
Server Chassis P4308 (UPL with redundant fan 4U)
Intel
®
Server Chassis P4XXX (UPL with redundant fan 4U)
Intel
®
Server Chassis R2208 (BHP with redundant fan 2U)
Intel
®
Server Chassis R2216 (BHP with redundant fan 2U)
Intel
®
Server Chassis R2224 (BHP with redundant fan 2U)
Intel
®
Server Chassis R2308 (BHP with redundant fan 2U)
Intel
®
Server Chassis R2312 (BHP with redundant fan 2U)
Fan domain definition
Chassis
Table 74. Intel
®
Server Board S2600IP - Fan Domain Definition
P4208/P4216/P4224/P4
308/P4XXX (UPL with redundant fan 4U)
Fan Domain
0
1
2
3
Major Components Cooled
(Temperature sensor number)
SSB Temp(22h)
BB BMC Temp(23h)
BB MEM VR Temp(25h)
I/O Mod Temp(26h)
HSBP 1 Temp(29h)
HSBP 2 Temp(2Ah)
SAS Mod Temp(2Dh)
Exit Air Temp(2Eh)
LAN NIC Temp(2Fh)
SSB Temp(22h)
BB BMC Temp(23h)
BB MEM VR Temp(25h)
I/O Mod Temp(26h)
HSBP 1 Temp(29h)
HSBP 2 Temp(2Ah)
SAS Mod Temp(2Dh)
Exit Air Temp(2Eh)
LAN NIC Temp(2Fh)
BB P2 VR Temp(24h)
BB MEM VR Temp(25h)
HSBP 1 Temp(29h)
HSBP 2 Temp(2Ah)
HSBP 3 Temp(2Bh)
SAS Mod Temp(2Dh)
Exit Air Temp(2Eh)
HDD 20 Status(64h)
HDD 21 Status(65h)
DIMM Thrm Mrgn 2(B1h)
DIMM Thrm Mrgn 3(B2h)
BB P2 VR Temp(24h)
HSBP 3 Temp(2Bh)
Exit Air Temp(2Eh)
P1 Therm Margin(74h)
Fans
(Sensor number)
System Fan 1(30h)
System Fan 2(31h)
System Fan 3(32h)
System Fan 4(33h)
142 Intel order number G34153-003 Revision 1.2
Chassis
R2208/R2216/R2224/P2
308/P2312 (BHP with redundant fan 2U)
Fan Domain
4
0
1
2
3
Major Components Cooled
(Temperature sensor number)
P2 Therm Margin(75h)
DIMM Thrm Mrgn 1(B0h)
DIMM Thrm Mrgn 4(B3h)
BB P2 VR Temp(24h)
HSBP 3 Temp(2Bh)
Exit Air Temp(2Eh)
PS1 Temperature(5Ch)
PS2 Temperature(5Dh)
HDD 20 Status(64h)
HDD 21 Status(65h)
DIMM Thrm Mrgn 1(B0h)
DIMM Thrm Mrgn 4(B3h)
SSB Temp(22h)
BB BMC Temp(23h)
BB MEM VR Temp(25h)
I/O Mod Temp(26h)
HSBP 1 Temp(29h)
HSBP 2 Temp(2Ah)
SAS Mod Temp(2Dh)
Exit Air Temp(2Eh)
LAN NIC Temp(2Fh)
SSB Temp(22h)
BB BMC Temp(23h)
BB MEM VR Temp(25h)
I/O Mod Temp(26h)
HSBP 1 Temp(29h)
HSBP 2 Temp(2Ah)
SAS Mod Temp(2Dh)
Exit Air Temp(2Eh)
LAN NIC Temp(2Fh)
SSB Temp(22h)
BB P2 VR Temp(24h)
HSBP 1 Temp(29h)
HSBP 2 Temp(2Ah)
P1 Therm Margin(74h)
P2 Therm Margin(75h)
P2 DTS Therm Mgn(84h)
DIMM Thrm Mrgn 2(B1h)
DIMM Thrm Mrgn 3(B2h)
BB P2 VR Temp(24h)
HSBP 1 Temp(29h)
HSBP 2 Temp(2Ah)
HSBP 3 Temp(2Bh)
Exit Air Temp(2Eh)
P1 Therm Margin(74h)
P2 Therm Margin(75h)
Revision 1.2 Intel order number G34153-003
Fans
(Sensor number)
System Fan 5(34h)
System Fan 1(30h)
System Fan 2(31h)
System Fan 3(32h)
System Fan 4(33h)
143
Chassis
Fan Domain
4
5
HSC Availability
Intel
®
Server Chassis P4208 (UPL) o 8bay 2.5” HDD – FXX8X25HSBP
Intel
®
Server Chassis P4216 (UPL) o 8bay 2.5” HDD – FXX8X25HSBP
Intel
®
Server Chassis P4224 (UPL) o 8bay 2.5” HDD – FXX8X25HSBP
Intel
®
Server Chassis P4308 (UPL) o 8-bay 3
.5” HDD – FUP8X35HSBP
Intel
®
Server Chassis R2208 (BHP) o 8bay 2.5” HDD – FXX8X25HSBP
Intel
®
Server Chassis R2216 (BHP) o 8bay 2.5” HDD – FXX8X25HSBP
Intel
®
Server Chassis R2224 (BHP) o 8bay 2.5” HDD – FXX8X25HSBP
Intel
®
Server Chassis R2308 (BHP) o 8-bay 3
.5” HDD – F2U8X35HSBP
Major Components Cooled
(Temperature sensor number)
DIMM Thrm Mrgn 1(B0h)
DIMM Thrm Mrgn 2(B1h)
DIMM Thrm Mrgn 3(B2h)
DIMM Thrm Mrgn 4(B3h)
SSB Temp(22h)
BB P2 VR Temp(24h)
HSBP 1 Temp(29h)
HSBP 2 Temp(2Ah)
P1 Therm Margin(74h)
P2 Therm Margin(75h)
P2 DTS Therm Mgn(84h)
DIMM Thrm Mrgn 2(B1h)
DIMM Thrm Mrgn 3(B2h)
BB P2 VR Temp(24h)
HSBP 1 Temp(29h)
HSBP 2 Temp(2Ah)
HSBP 3 Temp(2Bh)
Exit Air Temp(2Eh)
P1 Therm Margin(74h)
P2 Therm Margin(75h)
DIMM Thrm Mrgn 1(B0h)
DIMM Thrm Mrgn 2(B1h)
DIMM Thrm Mrgn 3(B2h)
DIMM Thrm Mrgn 4(B3h)
144 Intel order number G34153-003
Fans
(Sensor number)
System Fan 5(34h)
System Fan 6(35h)
Revision 1.2
Intel
®
Server Chassis R2312 (BHP) o 12-bay 3
.5” HDD – F2U12X35HSBP
Power unit support
Intel
®
Server Chassis P4208/P4216/P4224/P4308 (UPL)
Table 75. Intel
®
Server Chassis P4208/P4216/P4224/P4308 (UPL) Power support
PS Module
Number
PMBus*
Product Name (in product area of the FRU)
PSU
Redundant
Cold
Redundant
Fans in each PS
750W HS
Power Supply
1200W HS
Power Supply
Supported
Supported
DPS-750XB A
DPS-1200TB A
Supported
Supported
Supported
Supported
Intel
®
Server Chassis R2208/R2216/R2224/R2308/R2312 (BHP)
1 PS fan
2 PS fan
Table 76. Intel
®
Server Chassis R2208/R2216/R2224/R2308/R2312 (BHP) Power support
PS Module
Number
PMBus*
Product Name(in product area of the FRU)
PSU
Redundant
Cold
Redundant
Fans in each PS
750W HS
Power Supply
Supported FS750HS1-00 Supported Supported 1 PS fan
Redundant Fans only for Intel
®
Intel
®
Server Chassis P4208 (UPL with redundant fan 4U)
Intel
®
Server Chassis P4216 (UPL with redundant fan 4U)
Intel
®
Server Chassis P4224 (UPL with redundant fan 4U)
Intel
®
Server Chassis P4308 (UPL with redundant fan 4U)
Intel
®
Server Chassis P4XXX (UPL with redundant fan 4U)
Intel
®
Server Chassis R2208 (BHP with redundant fan 2U)
Intel
®
Server Chassis R2216 (BHP with redundant fan 2U)
Intel
®
Server Chassis R2224 (BHP with redundant fan 2U)
Intel
®
Server Chassis R2308 (BHP with redundant fan 2U)
Intel
®
Server Chassis R2312 (BHP with redundant fan 2U)
Fan Fault LED support
Fan fault LEDs are available on the baseboard and on the hot-swap redundant fans available on the following chassis:
Intel
®
Server Chassis P4208 (UPL with redundant fan 4U)
Intel
®
Server Chassis P4216 (UPL with redundant fan 4U)
Intel
®
Server Chassis P4224 (UPL with redundant fan 4U)
Intel
®
Server Chassis P4308 (UPL with redundant fan 4U)
Revision 1.2 Intel order number G34153-003 145
Intel
®
Server Chassis P4XXX (UPL with redundant fan 4U)
Intel
®
Server Chassis R2208 (BHP with redundant fan 2U)
Intel
®
Server Chassis R2216 (BHP with redundant fan 2U)
Intel
®
Server Chassis R2224 (BHP with redundant fan 2U)
Intel
®
Server Chassis R2308 (BHP with redundant fan 2U)
Intel
®
Server Chassis R2312 (BHP with redundant fan 2U)
Memory Throttling support
Baseboard supports this feature.
Intel
®
Workstation Board W2600CR
Introduction
This is an addendum document to BMC core EPS. This document describes platform and chassis specific information.
Product ID
Bytes 11:12 (product ID) of Get Device ID command response: 56h 00h
IPMI Channel ID Assignments
The following table provides information on the BMC channel assignments:
Table 77. Intel
®
Workstation Board W2600CR - BMC Channel Assignments
Channel ID Interface Supports
Sessions
Yes
Yes
Yes
Yes
0
1
2
3
4
5
6
Primary IPMB
LAN 1
LAN 2 (platform specific)
LAN3
1
(Provided by the Intel
®
Dedicated Server Management NIC)
Reserved
USB
Secondary IPMB
7
8
– 0Dh
0Eh
0Fh
Notes:
SMM
Reserved
Self
2
SMS/Receive Message Queue
1. Optional HW supported by the server system.
Yes
No
No
No
–
–
No
2. Refers to the actual channel used to send the request.
ACPI S3 Sleep State Support
Supported
146 Intel order number G34153-003 Revision 1.2
Processor Support for Intel
®
Intel
®
Xeon
®
processor E5-2600 product family up to 150 Watt
Intel
®
Xeon
®
processor E5-2600 v2 product family up to 150 Watt
Supported Chassis
Intel
®
Server Chassis P4304 (UPL with fixed fan 4U)
Chassis-specific sensors
Table 78. Intel
®
Workstation Board W2600CR - Chassis-specific sensors
Intel
®
Server Chassis
P4304 (UPL with fixed fan 4U)
Hot-plug fan support
Not supported.
Fan redundancy support
Not supported.
Fan Tachometer Sensors
System Fan 1(30h)
System Fan 2(31h)
Processor 1 Fan (36h) NA
Processor 2 Fan (37h) detected
NA
Fan
Presene
Sensors
NA
NA
Physical Security
(Chassis intrusion) sensor
FP Interrupt
(FP NMI Diag Int)
Physical Scrty(04h) FP NMI Diag Int(05h)
NA NA
NA
NA
NA
NA
Board specific feature
Board has not supported serial port A, and SOL will only use serial port B.
Fan domain definition
Table 79. Intel
®
Workstation Board W2600CR - Fan domain definition
Chassis
P4304 (UPL with fixed fan 4U)
Fan Domain
0
1
Major Components Cooled
(Temperature sensor number)
SSB Temp(22h)
BB BMC Temp(23h)
BB MEM VR Temp(25h)
I/O Mod Temp(26h)
SAS Mod Temp(2Dh)
Exit Air Temp(2Eh)
LAN NIC Temp(2Fh)
DIMM Thrm Mrgn 2(B1h)
DIMM Thrm Mrgn 3(B2h)
BB P2 VR Temp(24h)
BB MEM VR Temp(25h)
Exit Air Temp(2Eh)
HDD 20 Status(64h)
HDD 21 Status(65h)
DIMM Thrm Mrgn 1(B0h)
Fans
(Sensor number)
System Fan 1(30h)
System Fan 2(31h)
Revision 1.2 Intel order number G34153-003 147
Chassis
Fan Domain
6
7
Major Components Cooled
(Temperature sensor number)
DIMM Thrm Mrgn 2(B1h)
DIMM Thrm Mrgn 3(B2h)
DIMM Thrm Mrgn 4(B3h)
Exit Air Temp(2Eh)
P1 Therm Margin(74h)
BB P2 VR Temp(24h)
Exit Air Temp(2Eh)
P2 Therm Margin(75h)
Fans
(Sensor number)
Processor 1 Fan(36h)
Processor 2 Fan(37h)
HSC Availability
Not supported.
Power unit support
Intel
®
Server Chassis P4304 (UPL)
Table 80. Intel
®
Server Chassis P4304 (UPL) Power support
PS Module
Number
PMBus*
Product Name (in product area of the
FRU)
750W HS
Power Supply
1200W HS
Power Supply
Supported
Supported
DPS-750XB A
DPS-1200TB A
Redundant Fans only for Intel
®
Not supported.
Fan Fault LED support
Not supported.
Memory Throttling support
Baseboard supports this feature.
PSU Redundant
Supported
Supported
Cold
Redundant
Fans in each
PS
Supported 1 PS fan
Supported 2PS fan
148 Intel order number G34153-003 Revision 1.2
Appendix D: POST Code Diagnostic LED Decoder
During the system boot process, the BIOS executes a number of platform configuration processes, each of which is assigned a specific hex POST code number. As each configuration routine is started, the BIOS displays the POST code to the POST Code Diagnostic LEDs on the back edge of the server board. To assist in troubleshooting a system hang during the POST process, the Diagnostic LEDs can be used to identify the last POST process that was executed.
Each POST code is represented by a sequence of eight amber diagnostic LEDs. The POST codes are divided into two nibbles, an upper nibble and a lower nibble. The upper nibble bits are represented by diagnostic LEDs #4, #5, #6, and #7. The lower nibble bits are represented by diagnostics LEDs #0, #1, #2, and #3. If the bit is set in the upper and lower nibbles, then the corresponding LED is lit. If the bit is clear, then the corresponding LED is off.
The diagnostic LED #7 is labeled as “MSB”, and the diagnostic LED #0 is labeled as “LSB”.
Revision 1.2
Figure 36.
POST Code Diagnostic LED Decoder
Intel order number G34153-003 149
Note: Diagnostic LEDs are best read and decoded when viewing the LEDs from the back of the system
Table 81. POST Progress Code LED Example
LEDs
Status
MSB
LED #7
8h
ON
Upper Nibble AMBER LEDs
LED #6
4h
LED #5
2h
OFF ON
LED #4
1h
OFF
LED #3
8h
ON
Lower Nibble GREEN LEDs
LED #2
4h
LED #1
2h
ON OFF
LSB
LED #0
1h
OFF
1 0 1 0 1 1 0 0
Results
Ah Ch
Upper nibble bits = 1010b = Ah; Lower nibble bits = 1100b = Ch; the two are concatenated as
ACh
The following table provides a list of all POST progress codes.
Table 82. POST Progress Codes
Diagnostic LED Decoder
1 = LED On, 0 = LED Off
Upper Nibble Lower Nibble
Checkpoint
MSB LSB
8h 4h 2h 1h 8h 4h 2h 1h
LED # #7 #6 #5 #4 #3 #2 #1 #0
SEC Phase
01h
02h
0
0
0
0
0
0
0
0
0
0
0
0
0
1
Description
1 First POST code after CPU reset
0 Microcode load begin
03h
04h
05h
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
0
0
1 CRAM initialization begin
0 Pei Cache When Disabled
1 SEC Core At Power On Begin.
06h
07h
08h
09h
0Eh
0Fh
PEI Phase
10h
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
0
0
1
1
1
1
0
0
1
1
0 Early CPU initialization during Sec Phase.
1 Early SB initialization during Sec Phase.
0 Early NB initialization during Sec Phase.
1 End Of Sec Phase.
0 Microcode Not Found.
1 Microcode Not Loaded.
0 0 0 1 0 0 0 0 PEI Core
11h
15h
0
0
0
0
0
0
1
1
0
0
0
1
0
0
1 CPU PEIM
1 NB PEIM
19h 0 0 0 1 1 0 0 1 SB PEIM
MRC Process Codes
– MRC Progress Code Sequence is executed - See Table 83.
PEI Phase continued…
31h
32h
0 0 1 1 0 0 0 1 Memory Installed
0 0 1 1 0 0 1 0 CPU PEIM (Cpu Init)
33h
34h
0 0 1 1 0 0 1 1 CPU PEIM (Cache Init)
0 0 1 1 0 1 0 0 CPU PEIM (BSP Select)
35h 0 0 1 1 0 1 0 1 CPU PEIM (AP Init)
36h
4Fh
0
0
0
1
1
0
1
0
0
1
1
1
1
1
0 CPU PEIM (CPU SMM Init)
1 Dxe IPL started
DXE Phase
60h
61h
62h
0 1 1 0 0 0 0 0 DXE Core started
0 1 1 0 0 0 0 1 DXE NVRAM Init
0 1 1 0 0 0 1 0 SB RUN Init
150 Intel order number G34153-003 Revision 1.2
ABh
ACh
ADh
AEh
AFh
B0h
B1h
A2h
A3h
A4h
A5h
A6h
A7h
A8h
A9h
94h
95h
96h
97h
98h
99h
9Ah
9Bh
9Ch
9Dh
A1h
Diagnostic LED Decoder
1 = LED On, 0 = LED Off
Upper Nibble Lower Nibble
Checkpoint
MSB LSB
8h 4h 2h 1h 8h 4h 2h 1h
LED # #7 #6 #5 #4 #3 #2 #1 #0
63h 0 1 1 0 0 0 1 1 Dxe CPU Init
68h
69h
6Ah
70h
71h
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
0
0
0
1
1
1
1
1
0
0
0
0
0
0
0
0
0
1
0
0
0 DXE PCI Host Bridge Init
1 DXE NB Init
0 DXE NB SMM Init
0 DXE SB Init
1 DXE SB SMM Init
Description
72h
78h
79h
90h
91h
92h
93h
0 1 1 1 0 0 1 0 DXE SB devices Init
0 1 1 1 1 0 0 0 DXE ACPI Init
0 1 1 1 1 0 0 1 DXE CSM Init
1 0 0 1 0 0 0 0 DXE BDS Started
1 0 0 1 0 0 0 1 DXE BDS connect drivers
1 0 0 1 0 0 1 0 DXE PCI Bus begin
1 0 0 1 0 0 1 1 DXE PCI Bus HPC Init
1 0 0 1 0 1 0 0 DXE PCI Bus enumeration
1 0 0 1 0 1 0 1 DXE PCI Bus resource requested
1
1
1
1
1
0
0
0
1 0 0 1 1 0 0 1 DXE SIO Init
1 0 0 1 1 0 1 0 DXE USB start
0
0
0
0
0
0
0
1
1
1
1
1
0
0
1
1
1
1
1
0
0
1
1
1
0
1
0
0 DXE PCI Bus assign resource
1 DXE CON_OUT connect
0 DXE CON_IN connect
1 DXE USB reset
0 DXE USB detect
1 0 0 1 1 1 0 1 DXE USB enable
1 0 1 0 0 0 0 1 DXE IDE begin
1 0 1 0 0 0 1 0 DXE IDE reset
1 0 1 0 0 0 1 1 DXE IDE detect
1 0 1 0 0 1 0 0 DXE IDE enable
1 0 1 0 0 1 0 1 DXE SCSI begin
1 0 1 0 0 1 1 0 DXE SCSI reset
1 0 1 0 0 1 1 1 DXE SCSI detect
1 0 1 0 1 0 0 0 DXE SCSI enable
1 0 1 0 1 0 0 1 DXE verifying SETUP password
1 0 1 0 1 0 1 1 DXE SETUP start
1 0 1 0 1 1 0 0 DXE SETUP input wait
1 0 1 0 1 1 0 1 DXE Ready to Boot
1 0 1 0 1 1 1 0 DXE Legacy Boot
1 0 1 0 1 1 1 1 DXE Exit Boot Services
1 0 1 1 0 0 0 0 RT Set Virtual Address Map Begin
1 0 1 1 0 0 0 1 RT Set Virtual Address Map End
Revision 1.2 Intel order number G34153-003 151
Checkpoint
LED #
B2h
Diagnostic LED Decoder
1 = LED On, 0 = LED Off
Upper Nibble Lower Nibble
MSB LSB
8h 4h 2h 1h 8h 4h 2h 1h
#7 #6 #5 #4 #3 #2 #1 #0 Description
1 0 1 1 0 0 1 0 DXE Legacy Option ROM init
B3h 1 0 1 1 0 0 1 1 DXE Reset system
B4h
B5h
1 0 1 1 0 1 0 0 DXE USB Hot plug
1 0 1 1 0 1 0 1 DXE PCI BUS Hot plug
B6h
B7h
1 0 1 1 0 1 1 0 DXE NVRAM cleanup
1 0 1 1 0 1 1 1 DXE Configuration Reset
00h
S3 Resume
E0h
0 0 0 0 0 0 0 0 INT19
E1h
E2h
E3h
1 1 0 1 0 0 0 0 S3 Resume PEIM (S3 started)
1 1 0 1 0 0 0 1 S3 Resume PEIM (S3 boot script)
1 1 0 1 0 0 1 0 S3 Resume PEIM (S3 Video Repost)
1 1 0 1 0 0 1 1 S3 Resume PEIM (S3 OS wake)
BIOS Recovery
F0h 1 1 1 1 0 0 0 0 PEIM which detected forced Recovery condition
F1h 1 1 1 1 0 0 0 1 PEIM which detected User Recovery condition
F2h 1 1 1 1 0 0 1 0 Recovery PEIM (Recovery started)
F3h 1 1 1 1 0 0 1 1 Recovery PEIM (Capsule found)
F4h 1 1 1 1 0 1 0 0 Recovery PEIM (Capsule loaded)
POST Memory Initialization MRC Diagnostic Codes
There are two types of POST Diagnostic Codes displayed by the MRC during memory initialization; Progress Codes and Fatal Error Codes.
The MRC Progress Codes are displays to the Diagnostic LEDs that show the execution point in the MRC operational path at each step.
Table 83. MRC Progress Codes
Checkpoint
Diagnostic LED Decoder
1 = LED On, 0 = LED Off
Upper Nibble Lower Nibble
MSB
LED
MRC Progress Codes
LSB
8h 4h 2h 1h 8h 4h 2h 1h
#7 #6 #5 #4 #3 #2 #1 #0
B0h
B1h
B2h
B3h
B4h
1
1
1
1
1
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
1
0
0
1
1
0
0 Detect DIMM population
1 Set DDR3 frequency
Description
0 Gather remaining SPD data
1 Program registers on the memory controller level
0 Evaluate RAS modes and save rank information
152 Intel order number G34153-003 Revision 1.2
Checkpoint
LED
B5h
B6h
B7h
B8h
B9h
BAh
BBh
BCh
BFh
Diagnostic LED Decoder
1 = LED On, 0 = LED Off
Upper Nibble Lower Nibble
MSB LSB
8h 4h 2h 1h 8h 4h 2h 1h
#7 #6 #5 #4 #3 #2 #1 #0
Description
1 0 1 1 0 1 0 1 Program registers on the channel level
1 0 1 1 0 1 1 0 Perform the JEDEC defined initialization sequence
1 0 1 1 0 1 1 1 Train DDR3 ranks
1 0 1 1 1 0 0 0 Initialize CLTT/OLTT
1 0 1 1 1 0 0 1 Hardware memory test and init
1 0 1 1 1 0 1 0 Execute software memory init
1 0 1 1 1 0 1 1 Program memory map and interleaving
1 0 1 1 1 1 0 0 Program RAS configuration
1 0 1 1 1 1 1 1 MRC is done
Memory Initialization at the beginning of POST includes multiple functions, including: discovery, channel training, validation that the DIMM population is acceptable and functional, initialization of the IMC and other hardware settings, and initialization of applicable RAS configurations.
When a major memory initialization error occurs and prevents the system from booting with data integrity, a beep code is generated, the MRC will display a fatal error code on the diagnostic
LEDs, and a system halt command is executed. Fatal MRC error halts do NOT change the state of the System Status LED, and they do NOT get logged as SEL events. The following table lists all MRC fatal errors that are displayed to the Diagnostic LEDs.
Table 84. MRC Fatal Error Codes
Diagnostic LED Decoder
1 = LED On, 0 = LED Off
Checkpoint Upper Nibble
MSB
Lower Nibble
LSB
8h 4h 2h 1h 8h 4h 2h 1h
LED #7 #6 #5 #4 #3 #2 #1 #0
MRC Fatal Error Codes
E8h
E9h
EAh
EBh
1
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
0
0
1
1
0
1
0
1
Description
No usable memory error
01h = No memory was detected by SPD read, or invalid config that causes no operable memory.
02h = Memory DIMMs on all channels of all sockets are disabled due to hardware memtest error.
3h = No memory installed. All channels are disabled.
Memory is locked by Intel Trusted Execution Technology and is inaccessible
DDR3 channel training error
01h = Error on read DQ/DQS (Data/Data Strobe) init
02h = Error on Receive Enable
3h = Error on Write Leveling
04h = Error on write DQ/DQS (Data/Data Strobe
Memory test failure
01h = Software memtest failure.
Revision 1.2 Intel order number G34153-003 153
Checkpoint
LED
EDh
EFh
Diagnostic LED Decoder
1 = LED On, 0 = LED Off
Upper Nibble Lower Nibble
1 1 1 0 1 1 0 1
1 1 1 0 1 1 1 1
Description
MSB LSB
8h 4h 2h 1h 8h 4h 2h 1h
#7 #6 #5 #4 #3 #2 #1 #0
02h = Hardware memtest failed.
03h = Hardware Memtest failure in Lockstep Channel mode requiring a channel to be disabled. This is a fatal error which
requires a reset and calling MRC with a different RAS mode to
retry.
DIMM configuration population error
01h = Different DIMM types (UDIMM, RDIMM, LRDIMM) are detected installed in the system.
02h = Violation of DIMM population rules.
03h = The 3rd DIMM slot cannot be populated when QR DIMMs are installed.
04h = UDIMMs are not supported in the 3rd DIMM slot.
05h = Unsupported DIMM Voltage.
Indicates a CLTT table structure error
154 Intel order number G34153-003 Revision 1.2
Appendix E: POST Error Messages and Handling
Most error conditions encountered during POST are reported using POST Error Codes. These codes represent specific failures, warnings, or are informational. POST Error Codes may be displayed in the Error Manager display screen, and are always logged to the System Event Log
(SEL). Logged events are available to System Management applications, including Remote and
Out of Band (OOB) management.
There are exception cases in early initialization where system resources are not adequately initialized for handling POST Error Code reporting. These cases are primarily Fatal Error conditions resulting from initialization of processors and memory, and they are handed by a
Diagnostic LED display with a system halt.
The following table lists the supported POST Error Codes. Each error code is assigned an error type which determines the action the BIOS will take when the error is encountered. Error types include Minor, Major, and Fatal. The BIOS action for each is defined as follows:
Minor: The error message is displayed on the screen or on the Error Manager screen, and an error is logged to the SEL. The system continues booting in a degraded state.
The user may want to replace the erroneous unit. The POST Error Pause option setting in the BIOS setup does not have any effect on this error.
Major: The error message is displayed on the Error Manager screen, and an error is logged to the SEL. The POST Error Pause option setting in the BIOS setup determines whether the system pauses to the Error Manager for this type of error so the user can take immediate corrective action or the system continues booting.
Note that for 0048 “Password check failed”, the system halts, and then after the next reset/reboot will displays the error code on the Error Manager screen.
Fatal: The system halts during post at a blank screen with the text
“Unrecoverable
fatal error found. System will not boot until the error is resolved” and “Press <F2>
to enter setup” The POST Error Pause option setting in the BIOS setup does not have any effect with this class of error.
When the operator presses the F2 key on the keyboard, the error message is displayed on the Error Manager screen, and an error is logged to the SEL with the error code. The system cannot boot unless the error is resolved. The user needs to replace the faulty part and restart the system.
Note: The POST error codes in the following table are common to all current generation Intel server platforms. Features present on a given server board/system will determine which of the listed error codes are supported.
0012
Error Code
0048
0140
Table 85. POST Error Codes and Messages
System RTC date/time not set
Error Message
Password check failed
PCI component encountered a PERR error
Response
Major
Major
Major
Revision 1.2 Intel order number G34153-003 155
84FF
8500
8501
8520
8521
8522
8523
8524
8525
8526
8172
8173
8180
8181
8182
8183
8190
8198
8300
8305
83A0
83A1
84F2
84F3
84F4
5221
5224
8130
8131
8132
8133
8160
8161
8162
8163
8170
8171
0141
Error Code
0146
0191
0192
0194
0195
0196
0197
5220
Error Message
PCI resource conflict
PCI out of resources error
Processor core/thread count mismatch detected
Processor cache size mismatch detected
Processor family mismatch detected
Processor Intel(R) QPI link frequencies unable to synchronize
Processor model mismatch detected
Processor frequencies unable to synchronize
BIOS Settings reset to default settings
Passwords cleared by jumper
Password clear jumper is Set
Processor 01 disabled
Processor 02 disabled
Processor 03 disabled
Processor 04 disabled
Processor 01 unable to apply microcode update
Processor 02 unable to apply microcode update
Processor 03 unable to apply microcode update
Processor 04 unable to apply microcode update
Processor 01 failed Self Test (BIST)
Processor 02 failed Self Test (BIST)
Processor 03 failed Self Test (BIST)
Processor 04 failed Self Test (BIST)
Processor 01 microcode update not found
Processor 02 microcode update not found
Processor 03 microcode update not found
Processor 04 microcode update not found
Watchdog timer failed on last boot
OS boot watchdog timer failure
Baseboard management controller failed self-test
Hot Swap Controller failure
Management Engine (ME) failed Selftest
Management Engine (ME) Failed to respond.
Baseboard management controller failed to respond
Baseboard management controller in update mode
Sensor data record empty
System event log full
Memory component could not be configured in the selected RAS mode
DIMM Population Error
DIMM_A1 failed test/initialization
DIMM_A2 failed test/initialization
DIMM_A3 failed test/initialization
DIMM_B1 failed test/initialization
DIMM_B2 failed test/initialization
DIMM_B3 failed test/initialization
DIMM_C1 failed test/initialization
Minor
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Minor
Minor
Minor
Minor
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Response
Major
Major
Fatal
Fatal
Fatal
Fatal
Fatal
Fatal
Major
156 Intel order number G34153-003 Revision 1.2
8547
8548
8549
854A
854B
854C
854D
854E
854F
8550
8551
8552
8553
8540
8541
8542
8543
8544
8545
8546
8527
Error Code
8528
8529
852A
852B
852C
852D
852E
852F
8530
Error Message
DIMM_C2 failed test/initialization
DIMM_C3 failed test/initialization
DIMM_D1 failed test/initialization
DIMM_D2 failed test/initialization
DIMM_D3 failed test/initialization
DIMM_E1 failed test/initialization
DIMM_E2 failed test/initialization
DIMM_E3 failed test/initialization
DIMM_F1 failed test/initialization
DIMM_F2 failed test/initialization
8531
8532
8533
8534
8535
8536
8537
8538
DIMM_F3 failed test/initialization
DIMM_G1 failed test/initialization
DIMM_G2 failed test/initialization
DIMM_G3 failed test/initialization
DIMM_H1 failed test/initialization
DIMM_H2 failed test/initialization
DIMM_H3 failed test/initialization
DIMM_I1 failed test/initialization
8539
853A
853B
853C
853D
DIMM_I2 failed test/initialization
DIMM_I3 failed test/initialization
DIMM_J1 failed test/initialization
DIMM_J2 failed test/initialization
DIMM_J3 failed test/initialization
853E DIMM_K1 failed test/initialization
853F (Go to 85C0) DIMM_K2 failed test/initialization
DIMM_A1 disabled
DIMM_A2 disabled
DIMM_A3 disabled
DIMM_B1 disabled
DIMM_B2 disabled
DIMM_B3 disabled
DIMM_C1 disabled
DIMM_C2 disabled
DIMM_C3 disabled
DIMM_D1 disabled
DIMM_D2 disabled
DIMM_D3 disabled
DIMM_E1 disabled
DIMM_E2 disabled
DIMM_E3 disabled
DIMM_F1 disabled
DIMM_F2 disabled
DIMM_F3 disabled
DIMM_G1 disabled
DIMM_G2 disabled
Revision 1.2 Intel order number G34153-003
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Response
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
157
8564
8565
8566
8567
8568
8569
856A
856B
856C
8554
Error Code
8555
8556
8557
8558
8559
855A
855B
855C
855D
855E
855F
(Go to 85D0)
8560
8561
8562
8563
856D
856E
856F
8570
8571
8572
8573
8574
8575
8576
8577
8578
8579
857A
857B
857C
857D
857E
857F
(Go to 85E0)
Error Message
DIMM_G3 disabled
DIMM_H1 disabled
DIMM_H2 disabled
DIMM_H3 disabled
DIMM_I1 disabled
DIMM_I2 disabled
DIMM_I3 disabled
DIMM_J1 disabled
DIMM_J2 disabled
DIMM_J3 disabled
DIMM_K1 disabled
DIMM_K2 disabled
DIMM_A1 encountered a Serial Presence Detection (SPD) failure
DIMM_A2 encountered a Serial Presence Detection (SPD) failure
DIMM_A3 encountered a Serial Presence Detection (SPD) failure
DIMM_B1 encountered a Serial Presence Detection (SPD) failure
DIMM_B2 encountered a Serial Presence Detection (SPD) failure
DIMM_B3 encountered a Serial Presence Detection (SPD) failure
DIMM_C1 encountered a Serial Presence Detection (SPD) failure
DIMM_C2 encountered a Serial Presence Detection (SPD) failure
DIMM_C3 encountered a Serial Presence Detection (SPD) failure
DIMM_D1 encountered a Serial Presence Detection (SPD) failure
DIMM_D2 encountered a Serial Presence Detection (SPD) failure
DIMM_D3 encountered a Serial Presence Detection (SPD) failure
DIMM_E1 encountered a Serial Presence Detection (SPD) failure
DIMM_E2 encountered a Serial Presence Detection (SPD) failure
DIMM_E3 encountered a Serial Presence Detection (SPD) failure
DIMM_F1 encountered a Serial Presence Detection (SPD) failure
DIMM_F2 encountered a Serial Presence Detection (SPD) failure
DIMM_F3 encountered a Serial Presence Detection (SPD) failure
DIMM_G1 encountered a Serial Presence Detection (SPD) failure
DIMM_G2 encountered a Serial Presence Detection (SPD) failure
DIMM_G3 encountered a Serial Presence Detection (SPD) failure
DIMM_H1 encountered a Serial Presence Detection (SPD) failure
DIMM_H2 encountered a Serial Presence Detection (SPD) failure
DIMM_H3 encountered a Serial Presence Detection (SPD) failure
DIMM_I1 encountered a Serial Presence Detection (SPD) failure
DIMM_I2 encountered a Serial Presence Detection (SPD) failure
DIMM_I3 encountered a Serial Presence Detection (SPD) failure
DIMM_J1 encountered a Serial Presence Detection (SPD) failure
DIMM_J2 encountered a Serial Presence Detection (SPD) failure
DIMM_J3 encountered a Serial Presence Detection (SPD) failure
DIMM_K1 encountered a Serial Presence Detection (SPD) failure
DIMM_K2 encountered a Serial Presence Detection (SPD) failure
158 Intel order number G34153-003
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Response
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Revision 1.2
85CA
85CB
85CC
85CD
85CE
85CF
85D0
85D1
85D2
85D3
85D4
85D5
85D6
85D7
85D8
Error Code
85C0
85C1
85C2
85C3
85C4
85C5
85C6
85C7
85C8
85C9
85E0
85E1
85E2
85E3
85E4
85E5
85E6
85E7
85E8
85E9
85EA
85EB
85EC
85D9
85DA
85DB
85DC
85DD
85DE
85DF
Error Message
DIMM_K3 failed test/initialization
DIMM_L1 failed test/initialization
DIMM_L2 failed test/initialization
DIMM_L3 failed test/initialization
DIMM_M1 failed test/initialization
DIMM_M2 failed test/initialization
DIMM_M3 failed test/initialization
DIMM_N1 failed test/initialization
DIMM_N2 failed test/initialization
DIMM_N3 failed test/initialization
DIMM_O1 failed test/initialization
DIMM_O2 failed test/initialization
DIMM_O3 failed test/initialization
DIMM_P1 failed test/initialization
DIMM_P2 failed test/initialization
DIMM_P3 failed test/initialization
DIMM_K3 disabled
DIMM_L1 disabled
DIMM_L2 disabled
DIMM_L3 disabled
DIMM_M1 disabled
DIMM_M2 disabled
DIMM_M3 disabled
DIMM_N1 disabled
DIMM_N2 disabled
DIMM_N3 disabled
DIMM_O1 disabled
DIMM_O2 disabled
DIMM_O3 disabled
DIMM_P1 disabled
DIMM_P2 disabled
DIMM_P3 disabled
DIMM_K3 encountered a Serial Presence Detection (SPD) failure
DIMM_L1 encountered a Serial Presence Detection (SPD) failure
DIMM_L2 encountered a Serial Presence Detection (SPD) failure
DIMM_L3 encountered a Serial Presence Detection (SPD) failure
DIMM_M1 encountered a Serial Presence Detection (SPD) failure
DIMM_M2 encountered a Serial Presence Detection (SPD) failure
DIMM_M3 encountered a Serial Presence Detection (SPD) failure
DIMM_N1 encountered a Serial Presence Detection (SPD) failure
DIMM_N2 encountered a Serial Presence Detection (SPD) failure
DIMM_N3 encountered a Serial Presence Detection (SPD) failure
DIMM_O1 encountered a Serial Presence Detection (SPD) failure
DIMM_O2 encountered a Serial Presence Detection (SPD) failure
DIMM_O3 encountered a Serial Presence Detection (SPD) failure
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Response
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Revision 1.2 Intel order number G34153-003 159
Error Code
85ED
85EE
85EF
8604
8605
8606
92A3
92A9
A000
A001
A002
A003
A100
A421
A5A0
A5A1
A6A0
Error Message
DIMM_P1 encountered a Serial Presence Detection (SPD) failure
DIMM_P2 encountered a Serial Presence Detection (SPD) failure
DIMM_P3 encountered a Serial Presence Detection (SPD) failure
POST Reclaim of non-critical NVRAM variables
BIOS Settings are corrupted
NVRAM variable space was corrupted and has been reinitialized
Serial port component was not detected
Serial port component encountered a resource conflict error
TPM device not detected.
TPM device missing or not responding.
TPM device failure.
TPM device failed self test.
BIOS ACM Error
PCI component encountered a SERR error
PCI Express* component encountered a PERR error
PCI Express* component encountered an SERR error
DXE Boot Services driver: Not enough memory available to shadow a
Legacy Option ROM.
POST Error Beep Codes
The following table lists the POST error beep codes. Prior to system video initialization, the
BIOS uses these beep codes to inform users on error conditions. The beep code is followed by a user-visible code on the POST Progress LEDs
Table 86. POST Error Beep Codes
1
3
2
Beeps
USB device action
1 long Intel
Error Message
®
TXT security violation
Memory error
POST Progress Code
NA
0xAE, 0xAF
Description
Short beep sounded whenever a USB device is discovered in POST, or inserted or removed during runtime
System halted because Intel
®
Trusted Execution
Technology detected a potential violation of system security.
See Tables 28 and 29 System halted because a fatal error related to the memory was detected.
NA Recovery boot has been initiated
4
BIOS Recovery started
BIOS Recovery failure
NA BIOS recovery has failed. This typically happens so quickly after recovery us initiated that it sounds like a 2-4 beep code.
The Integrated BMC may generate beep codes upon detection of failure conditions. Beep codes are sounded each time the problem is discovered, such as on each power-up attempt, but are not sounded continuously. Codes that are common across all Intel server boards and systems that use same generation chipset are listed in the following table. Each digit in the code is represented by a sequence of beeps whose count is equal to the digit.
Minor
Minor
Major
Fatal
Minor
Fatal
Minor
Response
Major
Major
Major
Minor
Major
Major
Major
Major
Minor
Minor
160 Intel order number G34153-003 Revision 1.2
Table 87. Integrated BMC Beep Codes
Code Reason for Beep
1-5-2-1 No CPUs installed or first CPU socket is empty.
Associated Sensors
CPU1 socket is empty, or sockets are populated incorrectly
CPU1 must be populated before CPU2.
1-5-2-4 MSID Mismatch
1-5-4-2 Power fault
1-5-4-4 Power control fault (power good assertion timeout).
1-5-1-2 VR Watchdog Timer sensor assertion
1-5-1-4 Power Supply Status
MSID mismatch occurs if a processor is installed into a system board that has incompatible power capabilities.
DC power unexpectedly lost (power good dropout)
–
Power unit sensors report power unit failure offset
Power good assertion timeout
– Power unit sensors report soft power control failure offset
VR controller DC power on sequence was not completed in time.
The system does not power on or unexpectedly powers off and a Power Supply Unit (PSU) is present that is an incompatible model with one or more other PSUs in the system.
Revision 1.2 Intel order number G34153-003 161
Glossary
Glossary
GB
GPIO
GTL
HSC
Hz
I2C
IA
IBF
ICH
ICMB
IERR
IFB
DPC
EEPROM
EHCI
EMP
EPS
FMB
FMC
FMM
FRB
FRU
FSB
This appendix contains important terms used in the preceding chapters. For ease of use, numeric entries are listed first (for example, 82460GX) with alpha entries following (for example, AGP 4x). Acronyms are then entered in their respective place, with non-acronyms following.
Term
ACPI
AP
APIC
ASIC
BIOS
BIST
BMC
Bridge
BSP byte
CBC
CEK
CHAP
CMOS
Advanced Configuration and Power Interface
Application Processor
Advanced Programmable Interrupt Control
Application Specific Integrated Circuit
Basic Input/Output System
Definition
Built-In Self Test
Baseboard Management Controller
Circuitry connecting one computer bus to another, allowing an agent on one to access the other
Bootstrap Processor
8-bit quantity.
Chassis Bridge Controller (A microcontroller connected to one or more other CBCs, together they bridge the IPMB buses of multiple chassis.
Common Enabling Kit
Challenge Handshake Authentication Protocol
In terms of this specification, this describes the PC-AT compatible region of battery-backed 128 bytes of memory, which normally resides on the server board.
Direct Platform Control
Electrically Erasable Programmable Read-Only Memory
Enhanced Host Controller Interface
Emergency Management Port
External Product Specification
Flexible Mother Board
Flex Management Connector
Flex Management Module
Fault Resilient Booting
Field Replaceable Unit
Front Side Bus
1024MB
General Purpose I/O
Gunning Transceiver Logic
Hot-Swap Controller
Hertz (1 cycle/second)
Inter-Integrated Circuit Bus
Intel
®
Architecture
Input Buffer
I/O Controller Hub
Intelligent Chassis Management Bus
Internal Error
I/O and Firmware Bridge
162 Intel order number G34153-003 Revision 1.2
Intel®
MD2
MD5 ms
MTTR
Mux
NIC
NMI
LED
LPC
LUN
MAC
MB mBMC
MCH
Term
INTR
IP
IPMB
IPMI
IR
ITP
KB
KCS
LAN
LCD
Definition
Interrupt
Internet Protocol
Intelligent Platform Management Bus
Intelligent Platform Management Interface
Infrared
In-Target Probe
1024 bytes
Keyboard Controller Style
Local Area Network
Liquid Crystal Display
Light Emitting Diode
Low Pin Count
Logical Unit Number
Media Access Control
1024KB
National Semiconductor© PC87431x mini BMC
Memory Controller Hub
Message Digest 2
– Hashing Algorithm
Message Digest 5
– Hashing Algorithm – Higher Security milliseconds
Memory Tpe Range Register
Multiplexor
Network Interface Controller
Nonmaskable Interrupt
OBF
OEM
Ohm
PEF
PEP
PIA
PLD
PMI
POST
PSMI
PWM
RAM
RASUM
Output Buffer
Original Equipment Manufacturer
Unit of electrical resistance
Platform Event Filtering
Platform Event Paging
Platform Information Area (This feature configures the firmware for the platform hardware)
Programmable Logic Device
Platform Management Interrupt
Power-On Self Test
Power Supply Management Interface
Pulse-Width Modulation
Random Access Memory
Reliability, Availability, Serviceability, Usability, and Manageability
RISC
ROM
RTC
SDR
Reduced Instruction Set Computing
Read Only Memory
Real-Time Clock (Component of ICH peripheral chip on the server board)
Sensor Data Record
SECC Single Edge Connector Cartridge
SEEPROM Serial Electrically Erasable Programmable Read-Only Memory
SEL System Event Log
SIO Server Input/Output
Glossary
Revision 1.2 Intel order number G34153-003 163
Glossary
SMI
Term
SMM
SMS
SNMP
TBD
TIM
UART
UDP
UHCI
UTC
VID
VRD
Word
ZIF
Definition
Server Management Interrupt (SMI is the highest priority nonmaskable interrupt)
Server Management Mode
Server Management Software
Simple Network Management Protocol
To Be Determined
Thermal Interface Material
Universal Asynchronous Receiver/Transmitter
User Datagram Protocol
Universal Host Controller Interface
Universal time coordinare
Voltage Identification
Voltage Regulator Down
16-bit quantity
Zero Insertion Force
164 Intel order number G34153-003 Revision 1.2
Intel® Reference Documents
Reference Documents
See the following document for additional information:
BIOS for EPSD Platforms Based on Intel
®
Xeon Processor E5-4600/2600/2400/1600
Product Families External Product Specification
EPSD Platforms Based On Intel Xeon
®
Processor E5 4600/2600/2400/1600 Product
Families BMC Core Firmware External Product Specification
Intel
®
Intel
®
Intel
®
Server System P4000IP/CR Technical Product Specification
Server System R2000IP Technical Product Specification
Remote Management Module 4 Technical Product Specification
Intelligent Platform Management Interface Specification
SmaRT and
CLST Architecture on “Romley” Systems and Power Supplies Specification
(Doc Reference # 461024)
Intel Integrated RAID Module RMS25PB080, RMS25PB040, RMS25CB080, and
RMS25CB040 Hardware User
’s Guide
Revision 1.2 Intel order number G34153-003 165
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Intel
:
W2600CR2 S2600IP4
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 15 Introduction
- 15 Chapter Outline
- 15 Server Board Use Disclaimer
- 16 Product Overview
- 17 Product Feature Set
- 19 Main Board Connector and Component Layout
- 22 Main Board Rear I/O Layout
- 24 Server Board Mechanical Drawings
- 33 Functional Architecture
- 34 Processor Support
- 34 Processor Socket Assembly
- 35 Processor Population Rules
- 36 Processor Initialization Error Summary
- 39 Processor Functions Overview
- 40 QuickPath Interconnect
- 40 Integrated Memory Controller (IMC) and Memory Subsystem
- 46 Processor Integrated I/O Module (IIO)
- 48 C600-A Chipset Functional overview
- 48 Digital Media Interface (DMI)
- 48 PCI Express* Interface
- 48 Serial ATA (SATA) Controller
- 49 Serial Attached SCSI (SAS)/SATA (SCU) Controller
- 49 Rapid Storage Technology
- 50 PCI Interface
- 50 Low Pin Count (LPC) Interface
- 50 Serial Peripheral Interface (SPI)
- 50 Compatibility Modules (DMA Controller, Timer/Counters, Interrupt Controller)
- 50 Advanced Programmable Interrupt Controller (APIC)
- 50 Universal Serial Bus (USB) Controllers
- 50 Gigabit Ethernet Controller
- 51 Enhanced Power Management
- 51 Manageability
- 51 System Management Bus (SMBus* 2.0)
- 51 Integrated NVSRAM controller
- 52 Virtualization Technology for Directed I/O (Intel® VT-d)
- 52 JTAG Boundary-Scan
- 52 KVM/Serial Over Lan (SOL) Function
- 52 On-board SAS/SATA Support and Options
- 53 PCI Subsystem
- 54 Network Interface Controller
- 54 Network Interface
- 55 Workstation Board W2600CR2L)
- 56 SAS ROC Module Support
- 57 Workstation Board W2600CR Only)
- 60 Platform Management Overview
- 60 Server Management Function Architecture
- 60 Feature Support
- 62 Basic and Advanced Features
- 63 Integrated BMC Hardware: Emulex* Pilot III
- 65 Server Management Functional Specifications
- 65 BMC Internal Timestamp Clock
- 66 System Event Log (SEL)
- 66 Sensor Data Record (SDR) Repository
- 66 Field Replaceable Unit (FRU) Inventory Device
- 66 BMC Beep Codes
- 67 Diagnostic Interrupt (NMI) Button
- 67 BMC Watchdog
- 68 Sensor Monitoring
- 68 Overview
- 68 4600/2600/2400/1600/1400 Product Families
- 69 BMC System Management Health Monitoring
- 70 Processor Sensors
- 73 Thermal and Acoustic Management
- 74 Set Throttling Mode
- 74 Altitude
- 74 Set Fan Profile
- 74 Fan PWM Offset
- 74 Quiet Fan Idle Mode
- 75 Thermal Sensor Input for Fan Speed Control
- 76 Power Supply Status\Health Sensors
- 77 System Event Sensor
- 78 Platform Management Interface
- 79 Channel Management
- 79 User Model
- 79 LAN Interface
- 89 BMC Firmware Update
- 89 The BMC firmware release Number
- 89 Boot Recovery Mode
- 90 Force Firmware Update Jumper
- 90 Fast Firmware Update over USB
- 91 Advanced Management Feature Support
- 91 Enabling Advanced Management Features
- 91 Keyboard, Video, Mouse (KVM) Redirection
- 92 Media Redirection
- 94 Intelligent Power Node Manager (NM)
- 94 Overview
- 95 EU Lot 6 Mode
- 96 System Security
- 96 BIOS Password Protection
- 98 Trusted Platform Module (TPM) Support
- 98 TPM security BIOS
- 99 Physical Presence
- 99 TPM Security Setup Options
- 101 Trusted Execution Technology
- 102 Connector/Header Locations and Pin-outs
- 102 Power Connectors
- 102 Main Power Connector
- 102 CPU Power Connectors
- 102 Add-in Card Power Connectors
- 103 Front Panel Header and Connectors
- 103 Front Panel Header
- 104 Front Panel USB Connector
- 104 Local Control Panel Connector
- 104 On Board Storage Connectors
- 104 SATA Connectors: 6Gbps
- 105 Multiport Mini-SAS/SATA Connectors
- 106 RAID C600 Upgrade Key Connector
- 106 HSBP_I2C Header
- 106 HDD LED Header
- 106 Internal Type- A USB Connector
- 107 Internal eUSB SSD Header
- 107 Management and Security Connectors
- 107 RMM4_Lite Connector
- 107 RMM4_NIC Connector
- 108 TPM Connector
- 108 PMBus* Connector
- 108 Chassis Intrusion Header
- 108 IPMB Connector
- 108 FAN Connectors
- 109 System FAN Connectors
- 109 CPU FAN Connector
- 109 Serial Port and Video Connectors
- 109 Server Board S2600IP only)
- 110 Serial Port B Connector
- 110 Server Board S2600IP only)
- 111 Workstation Board W2600CR only)
- 112 Jumper Blocks
- 113 BIOS Default and Password Reset Usage Procedure
- 113 Set BIOS to default (Clearing the CMOS)
- 113 Clearing the Password
- 114 Force BMC Update Procedure
- 114 BIOS Recovery Jumper
- 115 ME Force Update Jumper
- 116 Light Guided Diagnostics
- 116 5-volt Stand-by LED
- 116 Fan Fault LED
- 116 CPU Fault LED
- 118 DIMM Fault LEDs
- 118 System ID LED, System Status LED and POST Code Diagnostic LEDs
- 119 System ID LED
- 120 System Status LED
- 121 POST Code Diagnostic LEDs
- 122 Design and Environmental Specifications
- 122 Products Design Specifications
- 125 Server Board Power Requirements
- 126 Processor Power Support
- 126 Output Power/Currents
- 126 Cross Loading
- 127 Standby Output
- 127 Voltage Regulation
- 127 Dynamic Loading
- 128 Capacitive Loading
- 128 Grounding