Schneider Automation TSX Nano, TSX Micro PLC Program Loader Module User Manual
PDF
سند
تبلیغات
تبلیغات
TSX PRG LDR TSX Nano/Micro program loader module Programm-Ladegerät TSX Micro/Nano Chargeur de programme TSX Nano/Micro Cargador de programa TSX Nano/Micro Caricatore di programmi TSX Nano/Micro Quick Reference Guide Bedienungsanleitung Instruction de service Instrucciones de uso Istruzioni d'uso Presentation The TSX PRG LDR module, which is compact and easy-to-use, offers the following functions for TSX Nano and TSX Micro PLCs : • Permanent backup (in FLASH EPROM) of an application (program and constants) • Fast duplication of applications and setting of the PLC to run mode after transfer • Updating of applications on site without the need for a programming terminal PLC memories used during application transfer The module reads the application in the RAM of the TSX Nano or TSX Micro PLC. The module writes the application to : • the RAM of the TSX Nano or TSX Micro PLC with an application smaller than 15 Kwords which do not have a PCMCIAcard, • the backup memory of the PLC : - EEPROM for TSX Nano PLCs, - FLASH EPROMfor TSX Micro PLCs with an application smaller than 15 Kwords which do not have a PCMCIA card. ! Caution Once the write operation is complete, the PLC automatically switches to RUN, unless it is conditioned by an input for this purpose. This product must not be connected to any port other than the terminal port. Physical description 1- 8-pin mini-DIN plug (RS 485 type) for connection to the PLC terminal port 2- 4 indicator lamps OK : module operating. Error : faults (see page 3). Write to TSX : writes an application to the PLC. Read from TSX : reads an application from the PLC. 3- Two buttons W/R : selects the direction of transfer, Write to TSX or Read from TSX. Enter : launches the selected transfer. 4- Two micro-switches Write only : inhibits the direction of transfer, Application Protection : used to read-protect the application after it has been transferred. 1 2 3 4 The module application is saved in a permanent memory (FLASH EPROM). 1 ENGLISH Functions Setup ENGLISH Reading an application To read an application, the operator should connect to the PLC containing the application. Lamp on Procedure 1 2 Lamp flashing Set the Write Only switch to OFF. Connect the module to the PLC terminal port. Lamp off Results and status of indicator lamps OK Error Write Read Running self-tests Module waiting for function 3 Select Read from TSX via the W/R button. Starts communication with the PLC Direction of transfer Read from TSX 4 Confirm the transfer with Enter. (active for a period of 3 seconds) Transfer in progress 5 6 Disconnect the module. Recommendation : set the Write Only switch to ON. Transfer complete Writing an application To transfer an application contained in the loader, the PLC connected must be the same type as that declared in the application. Procedure Results and status of indicator lamps OK Error Write Read 1 Connect the module to the PLC Running self-tests terminal port. Module waiting for function 2 Select Write to TSX via the W/R button. Starts communication with the PLC Direction of transfer Write to TSX 3 Confirm the transfer with Enter. (active for a period of 3 seconds) 4 Disconnect the module. Transfer in progress Transfer complete The Write Only option is used to read-protect the loader and thus avoid overwriting the application stored in the loader by a read error. 2 Setup ENGLISH Protecting the application Procedure 1 Read from a PLC where the application is not protected. 2 Set the Application Protection switch to ON. 3 Transfer the application to the target PLC. ! Important In order to ensure the integrity of the application, the Application Protection option cannot be reversed. Setting the switch from ON to OFF overwrites the application stored in the loader module. Types of error and diagnostics The following table summarizes the errors which may occur : Status of indicator lamps Meanings OK Error Write Read • PLC connected is not a TSX Nano or TSX Micro • V1.0 TSX Nano PLC (2A / 2B) • PLC reserved • TSX Micro PLC with PCMCIA memory card • Commmunication fault ( transmission speed and format not standard) • Module read-protected application (Write Only set to ON) and without stored • Module read-protected application (Write Only set to ON) connected to a PLC incompatible with the stored • Module without stored application and protected PLC application • Module without stored application and PLC application larger than 15 Kw • Module without stored application and PLC without application Fault during Write to TSX transfer Exit this state via the W/R key Fault during Read from TSX transfer Exit this state via the W/R key The following table summarizes the states limiting these functions : Write Read not permitted Read Write not permitted • • • • • • Module read-protected (Write Only set to ON). PLC application protected. PLC without application PLC application larger than 15 Kw. Module without stored application. Application stored in the module incompatible with the PLC connected (Compatibility test for TSX Micro applications). 3 Setup ENGLISH Other limitations Transfers of applications used as I/O to TSX Nano (rotary selector switch in positions 1,2,3,4) are not permitted. TSX Micro applications with a transmission speed and format for the terminal port in UNITELWAY master mode which are not configured for the standard cannot be managed by the program loader module. The various transfers permitted The module services and functions are managed by switches located on the base of the unit. Application stored Write Application Direction of transfer and services in the module Only Protection permitted → Module (Read) Application TSX OFF OFF TSX→ →TSX without protection (Write) Module→ → Module (Read) OFF ON TSX→ →TSX with protection (Write) Module→ →TSX without protection (Write) ON OFF Module→ →TSX with protection (Write) ON ON Module→ Application Protection ON OFF Write Only ON OFF Standards and characteristics The TSX PRG LDR module conforms to the following international norms and standards : CE marking DCEM / DBT EN standards EN 61131-2 / EN 55022 class A US standard UL508 CANADA standard CSA C22.2-142 Power supply 5 VDC supplied via the TSX terminal port Current consumption on 5 V 100 mA max. Operating temperature 0°C to +60°C (IEC 1131-2=+5°C to +55°C) Storage temperature -25°C to 70°C (IEC 1131-2) Relative humidity (no condensation) 10% to 95% Operating altitude <2000 m Electromagnetic compatibility Withstand to electrical discharges IEC 1000-4-2, level 3 Immunity to HF interference IEC 1000-4-3 / 4, level 3 / EN 55022 Resistance to LF interference IEC 1131-2 4 *W915905330801A02* Schneider Automation Inc. One High Street North Andover, MA 01845 Tel.: (1) 508 794 0800 - Fax: (1) 508 975 9010 Schneider Automation S.A. 245, route des Lucioles - BP 147 F-06903 Sophia Antipolis Tel.: (33) (0)4 92 96 20 00 - Fax: (33) (0)4 93 65 37 15 Schneider Automation GmbH Steinheimer Straße 117 D-63500 Seligenstadt Tel.: (49) 6182 81 2584 - Fax: (49) 6182 81 2860 Printed in July 1998 (831) ">
/
دانلود
فقط یک یادآوری دوستانه. می توانید سند را درست در اینجا مشاهده کنید. اما مهمتر از همه، هوش مصنوعی ما قبلاً آن را خوانده است. این می تواند موارد پیچیده را به زبان ساده توضیح دهد، به سوالات شما به هر زبانی پاسخ دهد و به شما کمک کند به سرعت حتی طولانی ترین یا پیچیده ترین اسناد را پیمایش کنید.
تبلیغات