Victron Energy 12,8V & 25,6V Lithium SuperPack Datasheet


Add to my manuals
1 Pages

advertisement

Victron Energy 12,8V & 25,6V Lithium SuperPack Datasheet | Manualzz

12,8V & 25,6V Lithium SuperPack batteries

www.victronenergy.com

Integrated BMS and safety switch

The SuperPack batteries are extremely easy to install, needing no additional components.

The internal switch will disconnect the battery in case of over discharge, over charge or high temperature.

Abuse proof

A lead-acid battery will fail prematurely due to sulfation:

• If it operates in deficit mode during long periods of time (i.e. if the battery is rarely, or never at all, fully charged).

• If it is left partially charged or worse, fully discharged.

A Lithium-Ion battery does not need to be fully charged. Service life even slightly improves in case of partial charge instead of a full charge. This is a major advantage of Li-ion compared to lead-acid.

The SuperPack batteries will cut-off the charge or discharge current when the maximum ratings are exceeded.

Efficient

In several applications (especially off-grid solar), energy efficiency can be of crucial importance.

The round-trip energy efficiency (discharge from 100% to 0% and back to 100% charged) of the average lead-acid battery is 80%.

The round-trip energy efficiency of a Li-ion battery is 92%.

The charge process of lead-acid batteries becomes particularly inefficient when the 80% state of charge has been reached, resulting in efficiencies of 50% or even less in solar systems where several days of reserve energy are required (battery operating in 70% to 100% charged state).

In contrast, a Li-ion battery will still achieve 90% efficiency even under shallow discharge conditions.

Can be connected in parallel

The batteries can be connected in parallel. Series connection is not allowed.

Use in upright position only.

Lithium SuperPack

12,8/20 12,8/60 12,8/100 12,8/200 25,6/50

Chemistry

Nominal voltage

Nominal capacity @ 25 ° C

Nominal capacity @ 0 ° C

Nominal energy @ 25 ° C

Cycle life @ 80% DoD and 25 ° C

20Ah

16Ah

256Wh

LiFePO4

60Ah

48Ah

768Wh

12,8V

100Ah

80Ah

1280Wh

2500 cycles

200Ah

160Ah

2560Wh

25,6V

50Ah

40Ah

1280Wh

CHARGE and DISCHARGE

Max. cont. discharge current*

Peak discharge current (10 sec)

End of discharge voltage

Charge voltage, absorption**

Charge voltage, float

Max. cont. charge current

30A

80A

15A

30A

80A

50A

100A

10V

14,2V – 14,4V

13,5V

30A 50A

70A

100A

70A

50A

100A

20V

28,4V – 28,8V

27V

50A

OPERATING CONDITIONS

Parallel configuration

Series configuration

Operating temperature

Storage temperature

Max. storage time when fully charged

Humidity (non-condensing)

Protection class

Yes, unlimited

No

Discharge: -10°C to +50°C Charge: +5°C to +45°C

-40°C to +65°C

1 year ≤ 25°C 3 months ≤ 40°C

Max. 95%

IP 43

OTHER

Power connection (threaded inserts)

Dimensions (LxWxH) mm

Weight

M6

181 x 77

x 167

3,5kg

M6

229 x 138 x 213

9,5kg

M8

330 x 171 x

220

14kg

M8

520 x 269 x 208

31kg

M8

330 x 171 x 220

* The battery may disconnect when a load with a high input capacitance is connected, such as an inverter. The battery

will however retry and connect after approximately 10 seconds.

**The absorption period should preferably not exceed 4 hrs. A longer absorption period may slightly reduce service life.

14kg