Ubiquiti airCam User guide


Add to my manuals
28 Pages

advertisement

Ubiquiti airCam User guide | Manualzz

Security Camera

Camera Configuration Interface

airCam ™ User Guide

Table of Contents

Chapter 1:

Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1

Package Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Installation Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

System Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Hardware Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Chapter 2:

Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2

Indoor Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Outdoor Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Connecting the Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Camera Configuration Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Adjusting the Camera View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Chapter 3:

Using the airCam Configuration Interface . . . . . . . . . . . . . . . .

6

Navigation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Chapter 4:

Main Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7

Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Chapter 5:

Video Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

9

Video Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Chapter 6:

Network Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

10

Network Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

VLAN Network Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

Firewall Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

Static Routes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

Advanced Ethernet Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

Chapter 7:

Services Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

13

Ping Watchdog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13

SNMP Agent. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14

Web Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14

SSH Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14

Telnet Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14

NTP Client . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14

Dynamic DNS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15

System Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15

Table of Contents

Ubiquiti Networks, Inc.

i

airCam ™ User Guide

Chapter 8:

System Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

16

Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16

Date Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16

System Accounts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17

Configuration Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17

Device Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17

Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18

Appendix A:

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

19

Appendix B:

Safety Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

20

Electrical Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20

Appendix C:

Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

21

General Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21

Appendix D:

Compliance Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

22

Installer Compliance Responsibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22

FCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22

Industry Canada . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22

Class B Korea . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22

CE Marking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22

RoHS/WEEE Compliance Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23

Appendix E:

Declaration of Conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . .

24

Appendix F:

Contact Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

25

Ubiquiti Networks Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25

Table of Contents

Ubiquiti Networks, Inc.

ii

airCam ™ User Guide

Chapter 1: Product Overview

Thank you for purchasing the airCam ™ , by Ubiquiti

Networks. The airCam is a professional-grade H.264 IP indoor/outdoor camera that features 1MP/HDTV 720p/30

FPS capabilities and works in low-light and night-viewing environments.

This User Guide is designed to provide intructions about installation of the airCam and to provide details about how to set up and use the airCam configuration interface.

The airCam includes the airVision ™ software. airVision is a comprehensive camera management software solution from Ubiquiti Networks, Inc. that is designed to work with

Ubiquiti’s airCam product line. The software interface design is based on the popular and easy to use UniFi software interface.

For instructions on using the software, refer to the documentation included on the CD-ROM.

The airCam includes the necessary hardware for properly mounting the unit to a wall both indoors and outdoors.

The airCam supports Passive PoE which works with the included PoE adapter.

The hardware installation process is different for indoor and outdoor installations. After familiarizing yourself with the airCam in the Hardware Overview section, please proceed to the appropriate installation section:

• “Indoor Installation” on page 2

• “Outdoor Installation” on page 3

Package Contents

Chapter 1: Product Overview

Hardware Overview

Front

Sun Shade

Lens

Back

Indoor Ethernet

Port Cover

Mounting Slots

Outdoor Ethernet

Port Cover

LEDs

Camera Mounting Bracket 24V PoE Adapter Power Cord

Self Tapping Screws

(Qty. 3)

Screw Anchors

(Qty. 3)

Security Camera

Quick Start Guide CD-ROM

Installation Requirements

• Pencil

• Drill and 6mm drill bits

System Requirements

• Microsoft Windows XP, Windows Vista, Windows 7, or

Mac OS X

• Java Runtime Environment 1.6 (or above)

• Web Browser: Mozilla Firefox, Google Chrome, or

Microsoft Internet Explorer 8 (or above)

Ubiquiti Networks, Inc.

Power The Power LED will light steady orange when the airCam is connected to a power source.

Ethernet The Ethernet LED will light steady green when an active Ethernet connection is made and flash when there is activity.

1

airCam ™ User Guide

Chapter 2: Installation

The installation process is different depending on if you are mounting the camera indoors or outdoors. Follow the instructions for the installation that you are performing.

Indoor Installation

1. Remove the screw and knob that connect the Mounting

Bracket Base to the camera attachment by turning the knob counter-clockwise.

Mounting Bracket Base

Chapter 2: Installation

4. Unscrew the Indoor Ethernet Port Cover on the back of the airCam.

5. Connect the Ethernet cable to the Ethernet port.

2. Insert an Ethernet cable through the Mounting Bracket

Base.

3. Reconnect the Mounting Bracket Base to the camera attachment by reconnecting the screw and knob. Turn the knob clockwise to lock the camera attachment back to the Mounting Bracket Base.

6. Position the Mounting Bracket in the desired location and use a pencil to mark the holes on the wall.

7. Use a 6 mm drill bit to drill the holes in the wall.

8. Insert the 3 screw anchors into the wall.

9. Secure the wall-mount bracket to the wall by inserting the self tapping screws into the anchors.

Note: There are three recessed areas for the

Ethernet cable on the Mounting Bracket Base.

Place the Ethernet cable in the recessed area that will be nearest to your power source.

Ubiquiti Networks, Inc.

2

airCam ™ User Guide

10. Insert the Mounting Bracket into the airCam until a click is heard to confirm a secure installation.

Chapter 2: Installation

2. Connect the Ethernet cable to the Ethernet port.

Continue to “Connecting the Power” on page 4.

Outdoor Installation

Important: The ideal outdoor location for mounting the airCam would be under an overhang/eave that shelters the camera. If the airCam is located in a completely open outdoor environment without an overhang/eave, do not install camera with a down tilt of more than 45 degrees.

Celing Mount

3. Reconnect the Outdoor Ethernet Port Cover to the airCam leaving the Ethernet cable fed through the bottom of the camera.

Wall-Mount

45

°

Camera is at 45 degrees when the indicator on the joint is aligned with the corner of the mounting arm.

1. Press down on the release to remove the Outdoor

Ethernet Port Cover.

4. Position the Mounting Bracket in the desired location and use a pencil to mark the holes on the wall.

5. Use a 6 mm drill bit to drill the holes in the wall.

6. Insert the 3 screw anchors into the wall.

Ubiquiti Networks, Inc.

3

airCam ™ User Guide

7. Secure the wall-mount bracket to the wall by inserting the self tapping screws into the anchors.

Chapter 2: Installation

2. Connect an Ethernet cable from your LAN to the

Ethernet port labeled LAN on the PoE Adapter.

Note: There are three recessed areas for the

Ethernet cable on the Mounting Bracket Base.

Place the Ethernet cable in the recessed area that will be nearest to your power source.

8. Insert the Mounting Bracket into the airCam until a click is heard to confirm a secure installation.

3. Connect the power cord to the power port on the PoE

Adapter. Connect the other end of the power cord to a power outlet. The Power LED should light up on the airCam.

Connecting the Power

1. Connect the other end of the Ethernet cable to the

Ethernet port labeled POE on the PoE Adapter.

Camera Configuration Interface

Verify connectivity in the Camera Configuration Interface.

1. Make sure that your host machine is connected to the same LAN as the airCam.

2. The airCam is set to DHCP by default. If you have a router or DHCP server providing addresses on your network, check your DHCP Client Table to obtain the address of the airCam.

Note: If you do not have a DHCP server, the airCam defaults to the IP address 192.168.1.20.

3. Launch your Web browser and in the address field, type http:// and then the IP address of the airCam, for example: http://192.168.1.20. Press enter (PC) or return (Mac).

Ubiquiti Networks, Inc.

4

airCam ™ User Guide

4. The login screen will appear. Enter ubnt in the

Username and Password fields and click Login.

5. The Main screen will appear and you should see a live stream of video from the airCam.

Adjusting the Camera View

Side to Side

Up and Down

Hardware installation is complete. For details on using the airVision software or the Camera Configuration Interface, refer to the documentation included on the CD-ROM.

Chapter 2: Installation

Ubiquiti Networks, Inc.

5

airCam ™ User Guide

Chapter 3: Using the airCam

Configuration Interface

The software that comes with your airCam has a browserbased interface for easy configuration and management.

To access the interface, perform the following steps:

1. Launch your Web browser and type

http://192.168.1.20 in the address field and press

Enter (PC) or Return (Mac).

2. The login screen will appear. Enter the admin name and password in the appropriate fields and click Login.

The airCam configuration interface appears.

Chapter 3: Using the airCam Configuration Interface

Navigation

The airCam configuration interface contains five main tabs, each of which provides a web-based management page containing configurable parameters that affect a specific aspect of the airCam:

• Main The Main tab displays airCam status/statistical information and provides video and client monitoring links.

• Video The Video tab allows you to configure Video

Settings including the Bit Rate, Quality, Frame Rate, and

Refresh Frequency for the airCam.

• Network The Network tab covers the configuration of the Network Settings, VLAN Network Settings,

Firewall Settings, Static Routes, TCP Explicit Congestion

Notification and Advanced Ethernet Settings.

• Services The Services tab covers the configuration of system management services including Ping Watchdog,

SNMP Agent, Web Server, SSH Server, Telnet Server, NTP

Client, Dynamic DNS, and System Log.

• System The System tab contains controls for airCam

Device Settings, Date Settings, System Accounts,

Configuration Management and Device Maintenance.

The airCam configuration interface also contains network administration and monitoring tools including:

• Ping

• Traceroute

Ubiquiti Networks, Inc.

6

airCam ™ User Guide Chapter 4: Main Tab

Chapter 4: Main Tab

The Main tab displays airCam status/statistical information and provides video and client monitoring links.

Status

Monitor

Live View

Device Name Displays the customizable name (ID) of the airCam. The Device Name can be modified on the System tab.

Version Displays the version of the airVision software installed.

Uptime This is the total time the airCam has been running since last power up (reboot) or software upgrade. The time is displayed in days, hours, minutes and seconds.

Date Displays the current system date and time. The date and time are displayed in YEAR-MONTH-DAY

HOURS:MINUTES:SECONDS format. The system date and time is retrieved from the Internet using NTP (Network Time Protocol).

The NTP Client is enabled by default on the Services tab. The device doesn’t have an internal clock and the date and time may be inaccurate if the NTP Client is disabled or the device isn’t connected to the Internet.

MAC Address Displays the Media Access Control (MAC) address of the airCam.

LAN Indicates the current status of the Ethernet port(s) connection. This can indicate that a cable is not plugged into a device and there is no active Ethernet connection. When cable is plugged in, negotiated data rate will be displayed; possible rates are 10Mbps or 100Mbps, or else Half duplex or Full duplex.

Ubiquiti Networks, Inc.

Displays a live video view based on the settings configured on the Video tab.

7

airCam ™ User Guide

Camera Controls

Camera controls appear when the mouse pointer is placed over the Live View. Use the sliders to adjust Brightness, Contrast,

Saturation and Sharpness settings. Click Remember to save camera settings.

Connected Clients

Displays a list of clients that are currently viewing the video stream.

Throughput

Chapter 4: Main Tab

Netmask Displays the airCam’s Netmask when operating in

DHCP Client mode. It is assigned automatically by the DHCP server, which also assigns the IP address to the airCam.

Gateway Displays the airCam’s gateway when operating in

DHCP Client mode, which is assigned automatically by the DHCP server.

Primary/Secondary DNS IP Domain Name System (DNS) is an Internet “phone book” which translates domain names to IP addresses. These fields identify the server IP addresses that the airCam uses for translation.

DHCP Server Displays the IP address of the DHCP Server assigning the IP Address to the airCam.

Domain Displays the domain name.

Total Lease Time Shows the total time (validity) of the leased IP address assigned by the DHCP server.

Remaining Lease Time Displays the remaining time of the IP address leased by the DHCP server.

ARP Table

Lists all the entries of the Address Resolution Protocol (ARP) table currently recorded on the airCam.

ARP is used to associate each IP address to the unique hardware

Media Access Control (MAC) address of each device. It is important to have unique IP addresses for each MAC address or else there will be ambiguous routes in the network.

Throughput displays a visual representation of the current data traffic on the LAN in both graphical and numerical form.

The chart scale and throughput dimension (Bps, Kbps, Mbps) changes dynamically according to the mean throughput value.

The statistics are updated automatically. Throughput statistics can be updated manually clicking Refresh.

DHCP Client

Shows the device’s IP address, Netmask, Gateway, DNS Servers,

DHCP Server, Domain, Total Lease Time and Remaining Lease

Time. DHCP Client mode can be enabled on the Network tab.

IP Address Displays the assigned IP address.

MAC Address Displays the Media Access Control (MAC) address of the device.

Interface Displays the interface that the device is on.

Refresh The information in the ARP Table window can be updated by clicking Refresh.

Log

Lists all registered system events. By default, logging is not enabled. The Log can be enabled on the Services tab.

IP Address Displays the airCam’s IP address while operating in DHCP Client mode. It is assigned automatically by the DHCP server.

Clear All entries in the system log can be deleted by clicking

Delete.

Refresh System Log content can be updated by clicking

Refresh.

Ubiquiti Networks, Inc.

8

airCam ™ User Guide Chapter 5: Video Tab

Chapter 5: Video Tab

The Video tab allows you to configure basic Video Settings including the Bit Rate and Quality and Advanced Settings including Resolution, Frame Rate, IP Interval, Refresh Frequency,

MJPEG Quality and Image Rotation settings for the airCam.

Video Settings

Bit Rate, Kbit/s This option allows the selection of the bit rate in kilobits per second. Options include 16, 64, 128, 256, 512, 1024,

1536, 2048, 4096.

Quality This option allows the selection of the video quality.

Options include Poor, Medium, Standard, Good, Excellent and

Determined by Bitrate.

Frame Rate, fps This option allows the selection of the airCam’s video frame rate in frames per second. Options include 1, 2, 3, 4,

5, 7, 10, 15, 20, 25, 30.

Refresh Frequency, Hz This option allows the selection of the airCam’s video refresh frequency in hertz. Options include 50 Hz and 60 Hz.

Ubiquiti Networks, Inc.

9

airCam ™ User Guide Chapter 6: Network Tab

Chapter 6: Network Tab

The Network tab covers the configuration of the Network

Settings, VLAN Network Settings, Firewall Settings, Static Routes,

TCP Explicit Congestion Notification and Advanced Ethernet

Settings.

Network Settings

IP Address The airCam can be set for static IP or can be set to obtain an IP address from the DHCP server it is connected to.

One of the IP assignment modes must be selected:

• DHCP Choose this option to assign a dynamic IP address,

Netmask, Gateway and DNS address by the local DHCP server.

DHCP Fallback IP Enter the IP address for the airCam to use if a DHCP server is not found.

DHCP Fallback Netmask Enter the Netmask for the airCam to use if a DHCP server is not found.

• Static Choose this option to assign the static IP settings for the airCam.

Ubiquiti Networks, Inc.

Note: IP Address and Netmask settings should be consistent with the address space of the network segment where the device resides.

IP Address Enter the IP address of the airCam. This IP will be used for device management purposes.

Netmask This is a value which when expanded into binary provides a mapping to define which portions of IP address groups can be classified as host devices and network devices. Netmask defines the address space of the network segment where the device resides. 255.255.255.0 (or /24)

Netmask is commonly used on many C Class IP networks.

Gateway IP Typically, this is the IP address of the host router which provides the point of connection to the

Internet. This can be a DSL Modem, Cable Modem, or a WISP

Gateway Router. The airCam will direct the packets of data to the gateway if the destination host is not within the local network.

Primary DNS IP Enter the IP address of the Primary DNS

(Domain Name System) server.

Secondary DNS IP Enter the IP address of the Secondary

DNS (Domain Name System) server. This entry is optional and only used if the primary DNS server is not responding.

10

airCam ™ User Guide

MTU Enter the size (in bytes) of the largest protocol data unit the layer can pass on. When using slow links, large packets can cause some delays thereby increasing lag and latency. By default, the MTU is set to 1500 bytes.

Auto IP Aliasing Automatically generates an IP Address for the corresponding LAN interface if enabled. The generated IP address is a unique Class B IP address from the 169.254.X.Y range

(Netmask 255.255.0.0) which is intended for use within the same network segment only. Auto IP always starts with 169.254.X.Y while X and Y are last 2 digits from the MAC address of the device

(i.e. if the MAC is 00:15:6D:A3:04:FB, Generated unique Auto IP will be 169.254.4.251).

IP Aliases IP aliases for the internal and external network interface can be configured. IP Aliases can be specified using the

LAN IP Aliases configuration window which is opened when you click Configure.

Chapter 6: Network Tab

Firewall Settings

Firewall functionality can be enabled by clicking Enable Firewall.

Firewall rules can be configured, enabled or disabled using the

Firewall configuration window which opens when you click

Configure.

• IP The alternative IP address for the LAN interface, which can be used for the routing or device management purposes.

• Netmask The network address space identifier for the particular IP Alias.

• Comments Field used for a brief description of the purpose of the IP Alias.

• Enabled Enables or disables the particular IP Alias. All added

IP Aliases are saved in the system configuration file, however only the enabled IP Aliases are active on the device.

Newly-added IP Aliases can be saved by click the Save button or discarded by clicking the Cancel button in the LAN IP Aliases configuration window.

VLAN Network Settings

Enable VLAN Enable this this feature to allow the management of the device to only occur on a specific management VLAN.

VLAN ID The VLAN ID is a unique value assigned to each VLAN at a single device; every VLAN ID represents a different Virtual

Network. VLAN ID range values between 2 and 4094 are allowed.

Only one VLAN ID is allowed per device.

VLAN Network Defines which network interface will be assigned to the specified VLAN ID.

Ubiquiti Networks, Inc.

Firewall entries can be specified by using the following criteria:

Action Allows two specific firewall rules: ACCEPT or DROP. By enabling ACCEPT the packets can pass the firewall unmodified.

When choosing DROP, the packets are denied passage through the firewall and no response is sent.

Interface The interface where filtering of the incoming/passingthrough packets are processed.

IP Type Sets which particular L3 protocol type (IP, ICMP, TCP,

UDP) should be filtered.

Source IP/Mask The source IP of the packet (specified within the packet header), usually it is the IP of the host system which sends the packets.

Src Port The source port of the TCP/UDP packet (specified within the packet header), usually it is the port of the host system application which sends the packets.

Destination IP/Mask The destination IP of the packet (specified within the packet header), usually it is the IP of the system which the packet is addressed to.

Dst Port The destination port of the TCP/UDP packet (specified within the packet header), usually it is the port of the host system application which the packet is addressed to.

Comment Field used to enter a brief description of the firewall entry.

On Enables or disables the effect of the particular firewall entry.

All added firewall entries are saved in system configuration file, however only the enabled firewall entries will be active on the device.

Not Can be used for inverting the Source IP/mask, Source Port,

Destination IP/mask and Destination Port filtering criteria (i.e. if not is enabled for the specified Destination Port value 443, the filtering criteria will be applied to all the packets sent to any

Destination Port except the 443 which is commonly used by

HTTPS).

Click Save to save your firewall entries or click Cancel to discard your changes.

11

airCam ™ User Guide

Static Routes

Static routing rules can be added manually to the System

Routing Table, allowing the specification of target IP address(es) that may pass through a determined gateway.

Static Routes functionality can be enabled by clicking Configure.

For each entry, specify a valid Target Network IP, Netmask,

Gateway IP, enter a Comment (optional), and select the ON check box, in order to enable this rule.

Chapter 6: Network Tab

Advanced Ethernet Settings

Enable Autonegotiation When enabled, the airCam will automatically negotiate transmission parameters with the counterpart, such as Link Speed and Duplex. In this process, the connected devices first share their capabilities as for these parameters and then choose the fastest transmission mode they both support. To specify these values manually, clear the Enable

Autonegotitation check box and select the appropriate values below.

Enable LED Selection turns LED next to the internal Ethernet port or or off.

Link Speed, Mbps Selects the maximum transmission link speed. There are two options: 10Mbps or 100Mbps. If running extra long Ethernet cables, a link speed of 10Mbps could help to achieve better stability.

Enable Full Duplex Selects the duplex mode; if enabled, the device operates in Full Duplex (allowing bidirectional communication in both directions simultaneously). While disabled, the device operates in Half-Duplex mode (allowing bidirectional communication in both directions, but not simultaneously and only in one direction at a time.

Click Save to apply changes or Cancel to discard them.

Click Change to save the changes made in the Network tab.

TCP Explicit Congestion Notification

Transmission Control Protocol (TCP) Explicit Congestion

Notification (ECN) can be enabled by selected TCP ECN.

When enabled, TCP ECN reduces the number of packets dropped by the TCP connection. By avoiding a retransmission, this results in reduced latency and jitter.

Note: ECN is an optional feature that must be supported and enabled on both endpoints. TCP ECN is disabled on the airCam by default.

Ubiquiti Networks, Inc.

12

airCam ™ User Guide Chapter 7: Services Tab

Chapter 7: Services Tab

The Services tab covers the configuration of system management services including Ping Watchdog, SNMP Agent, Web Server, SSH

Server, Telnet Server, NTP Client, Dynamic DNS, and System Log.

Ping Watchdog

Ping Watchdog sets the airCam to continuously ping a user defined IP address (it can be the Internet gateway for example).

If it is unable to ping under the user defined constraints, the airCam will automatically reboot. This option creates a kind of

“fail-proof” mechanism.

Ping Watchdog is dedicated for continuous monitoring of the particular connection to remote host using the Ping tool. The

Ping works by sending ICMP “echo request” packets to the target host and listening for ICMP “echo response” replies. If the defined number of replies is not received, the tool reboots the airCam.

• Startup Delay Specify initial time delay (in seconds) until the first ICMP echo requests are sent by the Ping Watchdog tool.

The default value is 300 seconds.

The value of Startup Delay should be at least 60 seconds as the network interface and wireless connection initialization takes a considerable amount of time if the airCam is rebooted.

• Failure Count to Reboot Specify the number of ICMP echo response replies. If the specified number of ICMP echo response packets is not received continuously, the Ping

Watchdog tool will reboot the airCam. The default value is 3.

Enable Ping Watchdog Enables the Ping Watchdog tool.

• IP Address To Ping Specify the IP address of the target host which to be monitored by the Ping Watchdog tool.

• Ping Interval Specify time interval (in seconds) between the

ICMP “echo requests” are sent by the Ping Watchdog Tool. The default value is 300 seconds.

Ubiquiti Networks, Inc.

13

airCam ™ User Guide

SNMP Agent

Simple Network Monitor Protocol (SNMP) is used in network management systems to monitor network-attached devices for conditions that warrant administrative attention. The airCam contains an SNMP agent which allows it to communicate to

SNMP manage applications for network provisioning.

The SNMP Agent provides an interface for device monitoring using the Simple Network Management Protocol (an application layer protocol that facilitates the exchange of management information between network devices). SNMP Agent allows network administrators to monitor network performance, find and solve network problems. For the purpose of equipment identification, it is always a good idea to configure SNMP agents with contact and location information:

Chapter 7: Services Tab

SSH Server

The following SSH Server parameters can be set:

Enable SSH Server This option enables SSH access to the airCam.

• Server Port SSH service TCP/IP port setting.

• Enable Password Authentication When enabled, you must authenticate using Administrator credentials in order to grant

SSH access to the airCam, otherwise an Authentication Key will be required.

• Authorized Keys Click Edit to import a public key file working to get SSH access to the airCam instead of using an admin password. Click Browse to locate and select the key file, then click Import. Click Save to save your changes or Close to discard your changes.

Telnet Server

The following Telnet Server parameters can be set:

Enable SNMP Agent Select to enable the SNMP Agent.

• SNMP Community Specify the SNMP community string. It is required to authenticate access to MIB objects and functions as an embedded password. The airCam supports a Readonly community string that gives read access to authorized management stations to all the objects in the MIB except the community strings, but does not allow write access. The airCam supports SNMP v1. The default SNMP Community is

public.

• Contact Specify the contact who that should be notified in case an emergency situation arises.

• Location Specify the physical location of the airCam.

Web Server

Enable Telnet Server This option activates the Telnet access to the airCam.

Server Port Telnet service TCP/IP port setting.

NTP Client

The Network Time Protocol (NTP) is a protocol for synchronizing the clocks of computer systems over packet-switched, variablelatency data networks. It can be used to set the airCam system time. System Time is reported next to the every System Log entry while registering system events if the Log option is enabled.

The following Web Server parameters can be set:

Use Secure Connection (HTTPS) If checked Web server will use secure HTTPS mode. HTTPS mode is unchecked by default.

• Secure Server Port Defines the Web Server TCP/IP port Use

Secure Connection (HTTPS) is enabled.

Server Port Web Server TCP/IP port setting while using HTTP mode.

Session Timeout Specifies the maximum timeout before the session expires. Once a session expires, you must login again using the username and password.

Enable NTP Client Enables the airCam to obtain the system time from a time server on the Internet.

• NTP Server Specify the IP address or domain name of the NTP

Server.

Ubiquiti Networks, Inc.

14

airCam ™ User Guide

Dynamic DNS

Enable Dynamic DNS Select this check box to enable Dynamic

DNS service for the airCam. Dynamic DNS is a network service providing which allows real-time notification to the DNS Server of any changes occurring in the airCam’s IP setting, there by allowing access to the airCam through a Domain Name even if the airCam’s IP address has changed.

Host Name Defines the Dynamic DNS Host Name. A large list of

Dynamic DNS services is available here.

Username Defines the Dynamic DNS Username.

Password Defines the Dynamic DNS password. Select Show to display the password.

System Log

Enable Log This option enables the registration routine of the system log messages. By default it is disabled.

• Enable Remote Log Enables the syslog remote sending function while System log messages are sent to a remote server specified in the Remote Log IP Address and Remote Log

Port fields.

Remote Log IP Address The host IP address where syslog messages should be sent. Remote host should be configured properly to receive syslog protocol messages.

Remote Log Port The TCP/IP port of the host syslog messages should be sent. 514 is the default port for the commonly used system message logging utilities.

Every logged message contains at least a System Time and a

Host Name. Usually a particular service name which generates the system event is specified also within the message. Messages from different services have different context and different level of the details. Usually error, warning or informational system service messages are reported, however more detailed Debug level messages can be reported also. The more detailed system messages are reported, the greater volume of log messages will be generated.

Chapter 7: Services Tab

Ubiquiti Networks, Inc.

15

airCam ™ User Guide Chapter 8: System Tab

Chapter 8: System Tab

The System tab contains controls for airCam Device Settings,

Date Settings, System Accounts, Configuration Management and

Device Maintenance.

Device

Device Name (Host name) is the system wide device identifier.

It is reported by the SNMP Agent to authorized management stations. Device Name will be represented in popular Router

Operating Systems registration screens and discovery tools.

Date Settings

Timezone Specifies the timezone according to GMT (Greenwich

Mean Time).

Enable Startup Date When enabled, you are able to modify the device’s startup date.

• Startup Date Specifies the device’s startup date. You can select a date by clicking the Calendar icon or typinh it in manually. Type the date in the following format:

2 digit month/2 digit day/4 digit year. An example would be for May 20th, 2010 your would type 05/20/2010

Device Name Specifies the system identity.

Interface Language Allows you to select the language displayed in the management interface. English is the default language.

Additional language profiles may be uploaded.

Refer to our wiki page at the following URL: www.ubnt.com/wiki/How_to_import_Language_Profile

Ubiquiti Networks, Inc.

16

airCam ™ User Guide

System Accounts

In this section you can modify the administrator password to protect your device from unauthorized configuration. The default administrator’s password should be changed on the very first system setup:

Chapter 8: System Tab

Note: The new configuration is active after clicking

Apply and the system reboot cycle is completed. The previous system configuration is deleted after you click

Apply. It is highly recommended to backup the system configuration before uploading the new configuration.

Device Maintenance

The controls in this section are dedicated for the device maintenance routines: rebooting, resetting, generating of the support information report.

Administrator Username Specifies the name of the system user.

Key button Press this button in order to change the administrator password.

• Current Password Enter the current password associated with the administrator account. It is required to change the

Password or Administrator Username.

• New Password Enter the new password for the administrator account.

• Verify New Password Re-enter the new password for the administrator account.

Note: Password length is 8 characters maximum, passwords exceeding 8 characters will be truncated.

Enable Read-Only Account Click to enable the read-only account and configure the username and password to protect your device from unauthorized access. The default option is

disabled.

• Read-Only Username Specifies the name of the system user.

• Key button Press this button in order to change the Readonly password.

New Password New password used for read-only administrator authentication should be specified.

Show Check this to display the read-only password characters you have typed.

Change Click to save changes to any of the fields on the System tab.

Configuration Management

The device configuration is stored in plain text file (cfg file). Use the Configuration Management controls to backup, restore or update the system configuration file:

Backup Configuration Click Download to download the current system configuration file.

Upload Configuration Click Browse to navigate to and select the new configuration file or specify the full path to the configuration file location. Click Upload to use a previously downloaded configuration file to the system. The settings of the new configuration will be visible in the Main, Network, Services and System tabs of the Web Management Interface.

Ubiquiti Networks, Inc.

Firmware Version Shows the current firmware version.

Build Number Displays the build number of the firmware version loaded.

Update Click to update the device with new firmware.

The device firmware update is compatible with all configuration settings. System configurations are preserved while the device is updated with a new firmware version.

• Current Firmware Displays the version of the airVision firmware which is currently operating.

• Firmware File Click Browse to locate new firmware file. Select the file and click Open. Once you’ve selected a new firmware file, click Upload to upload the new firmware to the device.

Click Close this window to cancel the new firmware upload process.

Update The Update button should be activated in order to proceed with firmware upgrade routine (new firmware image should be uploaded into the system first). Please be patient, as the firmware upgrade routine can take 3-7 minutes. The device will be inaccessible until the firmware upgrade routine is completed.

Do not switch off, do not reboot and do not disconnect the device from the power supply during the firmware upgrade process as these actions will damage the device!

It is highly recommended that you backup the system configuration and the Support Info file before uploading the new configuration.

Close this window At this point, closes the firmware upgrade window if activated. This action will not cancel the firmware upgrade process.

Reboot Activate Reboot control in order to initiate full reboot cycle of the airCam. Reboot is the same as the hardware reboot which is similar to the power off - power on cycle. The system configuration is not modified after the reboot cycle completes.

Any non-applied changes will be lost.

Reset to Defaults Use this to reset the airCam to the factory default settings. This option will reboot the airCam and all factory default settings will be restored. You may want to use the

Backup Configuration option to download your current settings before selecting this option.

Support Info This will generate a support information file that the Ubiquiti support engineers can use when providing customer support. This file only needs be generated at their request.

17

airCam ™ User Guide

Tools

Ping

The Ping tool is used to check the preliminary link quality and packet latency estimation between two network devices using

ICMP packets.

Network Ping

Select Destination IP A remote system IP can be selected from the list which is generated automatically or can be specified manually.

Packet Count Enter the number of packets to send for the ping test.

Packet Size The size of the ICMP packets can be specified in this field.

Start The test is started using this button.

Packet loss statistics and latency time evaluation is provided after the test is completed.

Traceroute

The TraceRoute tool allows tracing the hops from the device to a selected outgoing IP address. It should be used for finding the route taken by ICMP packets across the network to the

Destination host.

Destination Host Enter the IP address of the destination host to which you want to find the route.

Resolve IP Addresses Resolution of the IP addresses

(symbolically rather than numerically) can be enabled by selecting this option.

Start The test is started using this button.

Ubiquiti Networks, Inc.

Chapter 8: System Tab

18

airCam ™ User Guide

Appendix A: Specifications

Dimensions

Weight

Ports

Sensor

Lens

Horizontal of View

Ethernet Ports

Mbps

Power LED

Link Acive LED

Buttons

158 x 61.5 x 58.5 mm (without mounting arm)

264 x 61.5 x 58.5 mm (with mounting arm)

196 g (without mounting arm)

240 g (with mounting arm

(1) 10/100 Ethernet Ports

Progressive Scan RGB CMOS ¼”

4.0mm/ F1.5

47°

Auto MDIX, autosensing 10/100

Orange

Green

Factory Reset Button

Power Method Passive Power over Ethernet

(12-24V)

Power Supply 24V 0.5A PoE Adapter included

Max Power Usage

Certifications

2.4 Watts

CE, FCC, IC

Mounting Wall/Ceiling (Kit included)

Operating Temperature –40 to 70° C (-40 to 158° F)

Operating Humidity 20 - 80% Noncondensing

Video Settings

Video Compression

Max Resolution, px:

H.264/MPEG-4/MJPEG

1MP/HDTV 720p

Max Frame Rate, fps: 30

Image Setting Brightness, Contrast, Sharpness,

Saturation, 50Hz/60Hz

General

Processor

Memory

ARM-based 32-bit RISC

RJ-45 10BASE-T/100BASE-TX PoE

Connector RJ-45 10BASE-T/100BASE-TX PoE

Max Active Array Size 1280x800

View Angle 47° (H)

31° (V)

54° (D)

Appendix A: Specifications

Network

Security Multiple user access levels with password protection, User access

log

Supported Protocols IPv4/v6, HTTP, UPnP, DNS, NTP,

RTSP, DHCP, TCP, UDP, IGMP, RTCP,

ICMP, ARP

Ubiquiti Networks, Inc.

19

airCam ™ User Guide

Appendix B: Safety Notices

1. Read, follow, and keep these instructions.

2. Heed all warnings.

3. Only use attachments/accessories specified by the manufacturer.

WARNING: Do not use this product in location that can be submerged by water.

WARNING: Avoid using this product during an electrical storm. There may be a remote risk of electric shock from lightning.

Electrical Safety Information

1. Compliance is required with respect to voltage, frequency, and current requirements indicated on the manufacturer’s label. Connection to a different power source than those specified may result in improper operation, damage to the equipment or pose a fire hazard if the limitations are not followed.

2. There are no operator serviceable parts inside this equipment. Service should be provided only by a qualified service technician.

3. This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet.

a. Do not substitute the power cord with one that is not the provided approved type. Never use an adapter plug to connect to a 2-wire outlet as this will defeat the continuity of the grounding wire. b. The equipment requires the use of the ground wire as a part of the safety certification, modification or misuse can provide a shock hazard that can result in serious injury or death.

c. Contact a qualified electrician or the manufacturer if there are questions about the installation prior to connecting the equipment.

d. Protective earthing is provided by Listed AC adapter. Building installation shall provide appropriate short-circuit backup protection.

e. Protective bonding must be installed in accordance with local national wiring rules and regulations.

Appendix B: Safety Notices

Ubiquiti Networks, Inc.

20

airCam ™ User Guide

Appendix C: Warranty

General Warranty

UBIQUITI NETWORKS, Inc (“UBIQUITI NETWORKS”) represents and warrants that the Products furnished hereunder shall be free from defects in material and workmanship for a period of one (1) year from the date of shipment by UBIQUITI NETWORKS under normal use and operation. UBIQUITI NETWORKS sole and exclusive obligation under the foregoing warranty shall be to repair or replace, at its option, any defective Product that fails during the warranty period. The expense of removal and reinstallation of any item is not included in this warranty.

The foregoing warranty is exclusive and in lieu of all other warranties, express or implied, including the implied warranties of merchantability and fitness for a particular purpose and any warranties arising from a course of dealing, usage or trade practice with respect to the products. Repair or replacement in the manner provided herein shall be the sole and exclusive remedy of Buyer for breach of warranty and shall constitute fulfillment of all liabilities of UBIQUITI NETWORKS with respect to the quality and performance of the Products. UBIQUITI

NETWORKS reserves the right to inspect all defective

Products (which must be returned by Buyer to UBIQUITI

NETWORKS factory freight prepaid).

No Products will be accepted for replacement or repair without obtaining a Return Materials Authorization (RMA) number from UBIQUITI NETWORKS. Products returned without an RMA number will not be processed and will be returned to Buyer freight collect. UBIQUITI NETWORKS shall have no obligation to make repairs or replacement necessitated by catastrophe, fault, negligence, misuse, abuse, or accident by Buyer, Buyer’s customers or any other parties. The warranty period of any repaired or replaced. Product shall not extend beyond its original term.

Warranty Conditions

The foregoing warranty shall apply only if:

(I) The Product has not been subjected to misuse, neglect or unusual physical, electrical or electromagnetic stress, or some other type of accident.

(II) No modification, alteration or addition has been made to the Product by persons other than UBIQUITI

NETWORKS or UBIQUITI NETWORK’S authorized representatives or otherwise approved by UBIQUITI

NETWORKS.

(III) The Product has been properly installed and used at all times in accordance, and in all material respects, with the applicable Product documentation.

(IV) All Ethernet cabling runs use CAT5 (or above) shielded cabling.

Ubiquiti Networks, Inc.

Appendix C: Warranty

Disclaimer

UBIQUITI NETWORKS does not warrant that the operation of the products is error-free or that operation will be uninterrupted. In no event shall UBIQUITI NETWORKS be responsible for damages or claims of any nature or description relating to system performance, including coverage, buyer’s selection of products for buyer’s application and/or failure of products to meet government or regulatory requirements.

Returns

In the unlikely event a defect occurs, please work through the dealer or distributor from which this product was purchased.

21

airCam ™ User Guide

Appendix D: Compliance

Information

Installer Compliance Responsibility

Devices must be professionally installed and it is the professional installer’s responsibility to make sure the device is operated within local country regulatory requirements.

FCC

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provice reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Industry Canada

This Class B digital apparatus complies with Canadian

ICES-003.Operation is subject to the following two conditions:

1. This device may not cause interference, and

2. This device must accept any interference, including interference that may cause undesired operation of the device.

To reduce potential radio inteference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that permitted for successful communication.

Class B device (Broadcasting Communication Device for

Home Use): This device obtained EMC registration mainly for home use (Class B) and may be used in all areas.

Cet appareil numérique de la classe A est confrome à la norme NMB-003 Canada. Son fonctionnement est soumis aux deux conditions suivantes:

1. Cet appareil ne peut pas provoquer d’interférences et

2. Cet appareil doit accepter toute interférence, y compris les interférences susceptibles de provoquer un fonctionnement du dispositif.

Appendix D: Compliance Information

Pour réduire le risque d’interférence aux autres utilisateurs, l’antenne type et son gain doivent être choisies de façon que l’équivalent puissance isotrope rayonnée équivalente (pire) n’est pas plus que cela autorisé pour une communication réussie.

Class B Korea

Class B device (Broadcasting Communication Device for

Home Use): This device obtained EMC registration mainly for home use (Class B) and may be used in all areas.

CE Marking

CE marking on this product represents the product is in compliance with all directives that are applicable to it.

Alert sign! Follows CE marking

Alert sign must be indicated if a restriction on use applied to the product and it must follow the CE marking.

NB-Identification number (if there is any)

Notified body number is indicated if it is involved in the conformity assessment procedure.

Please check the CE mark on the product label to find out which notified body was involved during assessment.

Ubiquiti Networks, Inc.

22

airCam ™ User Guide

RoHS/WEEE Compliance Statement

English

European Directive 2002/96/EC requires that the equipment bearing this symbol on the product and/ or its packaging must not be disposed of with unsorted municipal waste. The symbol indicates that this product should be disposed of separately from regular household waste streams. It is your responsibility to dispose of this and other electric and electronic equipment via designated collection facilities appointed by the government or local authorities. Correct disposal and recycling will help prevent potential negative consequences to the environment and human health. For more detailed information about the disposal of your old equipment, please contact your local authorities, waste disposal service, or the shop where you purchased the product.

Deutsch

Die Europäische Richtlinie 2002/96/EC verlangt, dass technische Ausrüstung, die direkt am Gerät und/oder an der Verpackung mit diesem Symbol versehen ist , nicht zusammen mit unsortiertem Gemeindeabfall entsorgt werden darf. Das Symbol weist darauf hin, dass das

Produkt von regulärem Haushaltmüll getrennt entsorgt werden sollte. Es liegt in Ihrer Verantwortung, dieses Gerät und andere elektrische und elektronische Geräte über die dafür zuständigen und von der Regierung oder örtlichen

Behörden dazu bestimmten Sammelstellen zu entsorgen.

Ordnungsgemäßes Entsorgen und Recyceln trägt dazu bei, potentielle negative Folgen für Umwelt und die menschliche Gesundheit zu vermeiden. Wenn Sie weitere

Informationen zur Entsorgung Ihrer Altgeräte benötigen, wenden Sie sich bitte an die örtlichen Behörden oder städtischen Entsorgungsdienste oder an den Händler, bei dem Sie das Produkt erworben haben.

Español

La Directiva 2002/96/CE de la UE exige que los equipos que lleven este símbolo en el propio aparato y/o en su embalaje no deben eliminarse junto con otros residuos urbanos no seleccionados. El símbolo indica que el producto en cuestión debe separarse de los residuos domésticos convencionales con vistas a su eliminación. Es responsabilidad suya desechar este y cualesquiera otros aparatos eléctricos y electrónicos a través de los puntos de recogida que ponen a su disposición el gobierno y las autoridades locales. Al desechar y reciclar correctamente estos aparatos estará contribuyendo a evitar posibles consecuencias negativas para el medio ambiente y la salud de las personas. Si desea obtener información más

Ubiquiti Networks, Inc.

Appendix D: Compliance Information detallada sobre la eliminación segura de su aparato usado, consulte a las autoridades locales, al servicio de recogida y eliminación de residuos de su zona o pregunte en la tienda donde adquirió el producto.

Français

La directive européenne 2002/96/CE exige que l’équipement sur lequel est apposé ce symbole sur le produit et/ou son emballage ne soit pas jeté avec les autres ordures ménagères. Ce symbole indique que le produit doit être éliminé dans un circuit distinct de celui pour les déchets des ménages. Il est de votre responsabilité de jeter ce matériel ainsi que tout autre matériel électrique ou électronique par les moyens de collecte indiqués par le gouvernement et les pouvoirs publics des collectivités territoriales. L’élimination et le recyclage en bonne et due forme ont pour but de lutter contre l’impact néfaste potentiel de ce type de produits sur l’environnement et la santé publique. Pour plus d’informations sur le mode d’élimination de votre ancien

équipement, veuillez prendre contact avec les pouvoirs publics locaux, le service de traitement des déchets, ou l’endroit où vous avez acheté le produit.

Italiano

La direttiva europea 2002/96/EC richiede che le apparecchiature contrassegnate con questo simbolo sul prodotto e/o sull’imballaggio non siano smaltite insieme ai rifiuti urbani non differenziati. Il simbolo indica che questo prodotto non deve essere smaltito insieme ai normali rifiuti domestici. È responsabilità del proprietario smaltire sia questi prodotti sia le altre apparecchiature elettriche ed elettroniche mediante le specifiche strutture di raccolta indicate dal governo o dagli enti pubblici locali. Il corretto smaltimento ed il riciclaggio aiuteranno a prevenire conseguenze potenzialmente negative per l’ambiente e per la salute dell’essere umano. Per ricevere informazioni più dettagliate circa lo smaltimento delle vecchie apparecchiature in Vostro possesso, Vi invitiamo a contattare gli enti pubblici di competenza, il servizio di smaltimento rifiuti o il negozio nel quale avete acquistato il prodotto.

23

airCam ™ User Guide

Appendix E: Declaration of

Conformity

Česky

[Czech]

Dansk

[Danish]

Nederlands

[Dutch]

English

Eesti

[Estonian]

Suomi

[Finnish]

Français

[French]

Deutsch

[German]

Ελληνική

[Greek]

Magyar

[Hungarian]

Íslenska

[Icelandic]

Italiano

[Italian]

Latviski

[Latvian]

Lietuvi

[Lithuanian]

Malti

[Maltese]

Norsk

[Norwegian]

UBIQUITI NETWORKS tímto prohla uje, e tento UBIQUITI

NETWORKS device, je ve shod se základními po adavky a dal ími p íslu n mi ustanoveními sm rnice 1999/5/ES.

Undertegnede UBIQUITI NETWORKS erklærer herved, at følgende udstyr UBIQUITI NETWORKS device, overholder de væsentlige krav og øvrige relevante krav i direktiv 1999/5/EF.

Hierbij verklaart UBIQUITI NETWORKS dat het toestel UBIQUITI

NETWORKS device, in overeenstemming is met de essentiële eisen en de andere relevante bepalingen van richtlijn 1999/5/EG.

Bij deze verklaart UBIQUITI NETWORKS dat deze UBIQUITI

NETWORKS device, voldoet aan de essentiële eisen en aan de overige relevante bepalingen van Richtlijn 1999/5/EC.

Hereby, UBIQUITI NETWORKS, declares that this UBIQUITI

NETWORKS device, is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/

EC.

Käesolevaga kinnitab UBIQUITI NETWORKS seadme UBIQUITI

NETWORKS device, vastavust direktiivi 1999/5/EÜ põhinõuetele ja nimetatud direktiivist tulenevatele teistele asjakohastele sätetele.

UBIQUITI NETWORKS vakuuttaa täten että UBIQUITI NETWORKS device, tyyppinen laite on direktiivin 1999/5/EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen.

Par la présente UBIQUITI NETWORKS déclare que l’appareil

UBIQUITI NETWORKS, device est conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive

1999/5/CE.

Par la présente, UBIQUITI NETWORKS déclare que ce UBIQUITI

NETWORKS device, est conforme aux exigences essentielles et aux autres dispositions de la directive 1999/5/CE qui lui sont applicables.

Hiermit erklärt UBIQUITI NETWORKS, dass sich diese UBIQUITI

NETWORKS device, in Übereinstimmung mit den grundlegenden

Anforderungen und den anderen relevanten Vorschriften der

Richtlinie 1999/5/EG befindet”. (BMWi)

Hiermit erklärt UBIQUITI NETWORKS die Übereinstimmung des

Gerätes UBIQUITI NETWORKS device, mit den grundlegenden

Anforderungen und den anderen relevanten Festlegungen der

Richtlinie 1999/5/EG. (Wien)

ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ UBIQUITI NETWORKS ΔΗΛΩΝΕΙ ΟΤΙ UBIQUITI

NETWORKS device, ΣΥΜΜΟΡΦΩΝΕΤΑΙ ΠΡΟΣ ΤΙΣ ΟΥΣΙΩΔΕΙΣ

ΑΠΑΙΤΗΣΕΙΣ ΚΑΙ ΤΙΣ ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ ΔΙΑΤΑΞΕΙΣ ΤΗΣ ΟΔΗΓΙΑΣ

1995/5/ΕΚ.

Alulírott, UBIQUITI NETWORKS nyilatkozom, hogy a

UBIQUITI NETWORKS device, megfelel a vonatkozó alapvetõ követelményeknek és az 1999/5/EC irányelv egyéb elõírásainak.

Hér me l sir UBIQUITI NETWORKS yfir ví a UBIQUITI NETWORKS device, er í samræmi vi grunnkröfur og a rar kröfur, sem ger ar eru í tilskipun 1999/5/EC.

Con la presente UBIQUITI NETWORKS dichiara che questo

UBIQUITI NETWORKS device, è conforme ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999/5/

CE.

Ar o UBIQUITI NETWORKS deklar , ka UBIQUITI NETWORKS device, atbilst Direkt vas 1999/5/EK b tiskaj m pras b m un citiem ar to saist tajiem noteikumiem.

UBIQUITI NETWORKS deklaruoja, kad šis UBIQUITI NETWORKS įrenginys atitinka esminius reikalavimus ir kitas 1999/5/EB

Direktyvos nuostatas.

Hawnhekk, UBIQUITI NETWORKS, jiddikjara li dan UBIQUITI

NETWORKS device, jikkonforma mal- ti ijiet essenzjali u ma provvedimenti o rajn relevanti li hemm fid-Dirrettiva 1999/5/EC.

UBIQUITI NETWORKS erklærer herved at utstyret UBIQUITI

NETWORKS device, er i samsvar med de grunnleggende krav og

øvrige relevante krav i direktiv 1999/5/EF.

Appendix E: Declaration of Conformity

Slovensky

[Slovak]

Svenska

[Swedish]

Español

[Spanish]

Polski

[Polish]

Português

[Portuguese]

UBIQUITI NETWORKS t mto vyhlasuje, e UBIQUITI NETWORKS device, sp a základné po iadavky a v etky príslu né ustanovenia

Smernice 1999/5/ES.

Härmed intygar UBIQUITI NETWORKS att denna UBIQUITI

NETWORKS device, står I överensstämmelse med de väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av direktiv 1999/5/EG.

Por medio de la presente UBIQUITI NETWORKS declara que el UBIQUITI NETWORKS device, cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999/5/CE.

Niniejszym, firma UBIQUITI NETWORKS o wiadcza, e produkt serii

UBIQUITI NETWORKS device, spełnia zasadnicze wymagania i inne istotne postanowienia Dyrektywy 1999/5/EC.

UBIQUITI NETWORKS declara que este UBIQUITI NETWORKS device, está conforme com os requisitos essenciais e outras disposições da Directiva 1999/5/CE.

Ubiquiti Networks, Inc.

24

airCam ™ User Guide

Appendix F: Contact

Information

Ubiquiti Networks Support

Ubiquiti Support Engineers are located in the U.S. and

Europe and are dedicated to helping customers resolve software, hardware compatibility, or field issues as quickly as possible. We strive to respond to support inquiries within a 24 hour period.

Email: [email protected]

Phone: 408-942-1153 (9 a.m. - 5 p.m. PST)

Online Resources

Wiki Page: www.ubnt.com/wiki

Support Forum: www.ubnt.com/forum

Downloads: www.ubnt.com/support/downloads

91 E. Tasman Drive

San Jose, CA 95134 www.ubnt.com

© 2011 Ubiquiti Networks, Inc. All rights reserved.

Appendix F: Contact Information

Ubiquiti Networks, Inc.

MA083111

25

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals