advertisement
1
、
Installation Precautions
1.
When you open the product packaging, please check the product and accessories at first.
2 .
The hot and cold water supply pipe of the faucet must be properly
connected.When facing the front of the faucet, the hot water supply is
on the leftand cold water supply is on the right. Incorrect connection
will causepermanent damage to the cartridge.
3 .
If the accessories to be changed without affecting the use, we will notmake a prior notice.
4.
The impurities in the water supply pipe must be cleared before installation to avoid blockage.
5.
The water pressure of the faucet is 0.05MPa-1.0MPa (including cold water and hot water pressure).
Applicable water temperature range: 39 ℉ - 194 ℉
2 、
Preparation before installation
1 .
Please read the installation manual carefully before installation.
2 .
Installation work must be performed by a professional installer.
3 .
Installation tool :
1
5.3"
4 、
Technical drawing of drilling size
1 、 The size of the embedded box that needs to be drilled
is 5.3"*6.7".
5.3"
Top shower outlet water
Hot water
2 、 The depth of the embedded box is 1.8"-2.2".
It's better to drill the depth of 1.8"for blank wall.
2.2"
Handle shower outlet water wall cold water
Tile surface
3
5.3"
5 、
Pipe connection
1 、
Please drill the holes on the wall for the main body embedded part, hot and cold water inlet pipes as well as shower arm connection pipes according to the basic product dimension drawing as below.
2 、 Please make hot and cold water inlet pipe, the mixed water outlet
pipe connect with control valve,and tighten with the wrench
4
6 、
Water testing and sealing testing
1 、 After the pipe connection is completed, open the protective panel
and cover, and then open the cartridge, flush the pipeline;
then close the cartridge to check the pressure resistance and sealing
performance of the pipeline, make sure there are no leakage.
2 、 Block each outlet pipe with a stopper then open the cartridge to
check if the pipe joint is well-sealed and the pipe condition under
pressure to ensure no leakage.
Testing Purpose: Flush the impurities and sludge in the pipeline
to avoid clogging and affect the effluent functions.
5
7 、
The procedure of sealing the wall
Use a parallel ruler to measure the flatness of the embedded box
casing and the vertical wall surface. If the wall surface is not flat,
it should be patched to ensure the embedded box casing and vertical
wall angle meets at nearly ideal angle of 90, then lay the tile decoration.
wall
Tile surface
Protective cover is roughly even with tile
6
8 、
Installation of control valve
1 、
Take off the protective panel and cover
2 、 The decorative panel and the handle are connected to
the control valve as shown below sequence.
According to the figure below, please correctly adjust the direction of water separator handle
Top shower outlet water
Handle shower outlet water
7
advertisement