Schneider Electric Lexium Controller User's manual

The Lexium Controller is a motion controller that supports the Modbus protocol. It provides direct access to the Modbus protocol for configuration, adjustment, control and monitoring purposes. It offers a 2-wire RS485 physical layer and RTU transmission mode. The Lexium Controller can be used to connect a graphic display terminal, a Magelis industrial HMI terminal, a programmable controller (PLC), another controller or the Motion Pro/CoDeSys software workshop.

PDF
Document
Lexium Controller User's Manual | Manualzz

Advertisement

Advertisement

/

Advertisement

Key features

  • Supports Modbus RTU transmission mode

  • Provides direct access to Modbus protocol

  • Offers 2-wire RS485 physical layer

  • Can be used to connect a graphic display terminal

  • Can be used to connect Magelis industrial HMI terminal

  • Can be used to connect a programmable controller (PLC)

  • Can be used to connect another controller

  • Can be used to connect the Motion Pro/CoDeSys software workshop

Frequently asked questions

The Lexium Controller supports the following Modbus functions: Read Holding Registers (function 3), Write Single Register (function 6), Diagnostics (function 8), Write Multiple Registers (function 16) and Read Device Identification (function 43).

You can configure the Modbus address and baudrate using the graphic display terminal or the Motion Pro/CoDeSys software. The graphic display terminal allows configuring the Modbus address from 1 to 247, the baudrate can be set to 9600, 19200, or 38400. Using the Motion Pro/CoDeSys software, you can access the configuration using the PLC-Browser keyword mbusinf.

The Lexium Controller has an RJ45 connector for connecting to a Modbus network. You can use a Telemecanique cable with 2 pairs of shielded twisted conductors (references: TSXCSA100, TSXCSA200 or TSXCSA500) to connect the Lexium Controller to a Modbus network. The cable must be at least 30 cm away from the power cables. If it is necessary to cross the Modbus cables and the power cables, be sure they cross at right angles. As far as possible, connect the shielded cable to a protective ground. Install a line terminator at each end of the line. Check the polarity of the line. Connect the common signal to the protective ground at one or more points on the bus.

The Modbus LEDs are located on the RJ45 port, on the front panel of the Lexium Controller. Each LED lights up for 200ms when a frame is being transmitted on the corresponding Modbus network.

When a Modbus communication interruption occurs, you need to manage it by the Modbus master. The master can be a PLC, a PC, an industrial terminal (Magelis), or a SCADA system monitoring the Lexium Controller.