advertisement
▼
Scroll to page 2
of
11
Model: PA7010E & PA5010E 770-821-6204 TABLE OF CONTENTS Dehumidifier Safety 3 Installation Requirements 3 Electrical Requirements 3 Location Requirements 4 Dehumidifier Use 4 Setting the Controls 5 Draining the Dehumidifier 7 Normal Sounds 9 Dehumidifier Care 9 Cleaning the Air Filter 10 Cleaning the Dehumidifier 10 Troubleshooting 11 2 DEHUMIDIFIER SAFETY Your safety and safety of others are very important We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING”. These words mean: You can be killed or seriously injured if you do not immediately follow instructions. You can be killed or seriously injured if you do not follow instructions. All safety messages will tell you what the potential hazards are, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed. DISPOSING OF THE UNIT Before disposing of the remote control, it is necessary to remove the batteries and dispose of them in an environmentally responsible manner. When you need to dispose of the unit, consult with your local recycling center for information on how to dispose of the unit in an environmentally responsible manner. Please recycle or dispose of the packaging material for product in an environmentally responsible manner. IMPORTANT SAFETY INSTRUCTIONS WARNING: To reduce the risk of fire, electrical shock ,injury or sickness when using your dehumidifier , follow these basic precautions: • Plug into a grounded 3 prong outlet. • Do not use an extension cord. • Do not remove ground prong. • Unplug dehumidifier before servicing. • Do not use an adapter. • Do not drink water collected in the water bucket SAVE THESE INSTRUCTIONS INSTALLATION REQUIREMENTS Electrical Requirments Recommended Grounding Method This dehumidifier must be grounded. This dehumidifier is equipped with a power supply cord having a 3-prong grounding plug. The cord must be plugged into a mating, grounding 3-prong outlet, grounded in accordance with all local codes and ordinances. If a mating outlet is not available, it is the customer’s responsibility to have a properly grounded 3-prong outlet installed by a qualified electrical installer. It is the customer's responsibility: To contact a qualified electrical installer. To assure that the electrical installation is adequate and in conformance with Nation Electrical Code, ANSI/NFPA 70-last edition, and all local codes and ordinances. Copies of the standards listed may be obtained from: Nation Fire Protection Association 1 Battery march Park Quincy, MA 02169-7471 3 Location Requirments NOTE: Your model may differ from the one shown. Allow at least 12” to 18” (30.5 cm to 45.7 cm) of airspace on the side of the dehumidifier for models with side louvers and above the dehumidifier for models with top louvers. You will need a surface strong enough to support the dehumidifier when its bucket is full of water. You will need a surface level enough to keep the water from spilling when the bucket is full of water. Keep all outside doors, windows and other openings closed when you are operating the dehumidifier. Humid outdoor air will increase the dehumidifier workload. Install the dehumidifier in an area where the temperature will be at least 38°F (3°C). Lower temperatures will cause your performance to decrease. Do not block the louvers. Dehumidifier Use 4 Auto Dry - Will operate the dehumidifier only in the dry mode. Auto Fan Speed is set automatically. The desired humidity is set to 50% automatically. Continuous - Will operate the dehumidifier continuously. The Fan Speed can be adjusted. The Desired Humidity cannot be adjusted. The LED display will show the room humidity level. Normal - Will operate the dehumidifier at the selected fan speed and desired humidity. If the humidity level of the room is higher than the desired humidity setting, the compressor will turn on. If the humidity level of the room is lower than the desired humidity setting, the compressor will turn off. The deicer will turn off the compressor if a low temperature condition exists. Pressing the desired humidity button or the plus or minus arrow button will not increase or decrease the amount of moisture removed. When the deicer senses the correct operating temperature, the compressor will cycle back on. 5 6 If you plan to run your dehumidifier continuously, you may want to attach a garden hose to the drain hose connector. 1. 7 Turn the connector cover counter clockwise to remove it. 8 9 Cleaning the air filter a Cleaning the dehumidifier 10 TROUBLESHOOTING All models have an automatic deicer that will shut off the compressor and allow the fan to run. This reduces the ice buildup on the coils. The compressor will cycle back on when the deicer senses the correct operating temperature. Is the dehumidifier turned on? Turn on the dehumidifier. Is the power cord plugged into a grounded 3 prong outlet? Plug into a grounded: 3 prong outlet. See Electrical Requirements. Has a household fuse blown, or has a circuit breaker tripped? Replace the fuse or reset the circuit breaker. If the problem continues, call an electrician. See "Electrical Requirements.” Is the bucket installed properly? Reinstall the bucket so that it fits all the way into the dehumidifier. Does the bucket need to be emptied? Empty the bucket. All models have an automatic deicer that will shut off the compressor and allow the fan to run. When the deicer senses the correct operating temperature, the compressor will cycle back on. Is the control set to Continuous Run? If you have selected Continuous Run, the dehumidifier will run continuously. If the humidity level is low, little or no water may be collected. The filter is dirty or obstructed by debris. Clean the filter. Dehumidifier will put out warm air under normal operating conditions. Is the water level float in place? Remove the bucket. Make sure the float is snapped in place. Reinstall the bucket. 112912 11 1
advertisement
Related manuals
advertisement