MODEL: SDI07HY

Hybrid Portable Test Monitor

User Manual

Precautions

• Always handle the unit with care to avoid damaging the LCD display panel. Damage caused by physical shocks is not covered by the product warranty.

• Avoid getting fingerprints on the screen. To clean the screen, wipe it with a clean, soft and dry towel, being careful not to damage the LCD display panel.

• To reduce the risk of fire or electric shock, do not expose the LCD to rain or moisture.

• Do not connect power to the video input/output ports. It will cause a malfunction.

• Only use the approved battery charger included in the package – a fire may be caused if a non unapproved charger is used (if the red LED flickers during recharging, request after sales service).

• The built-in Li-Polymer battery (11.1V / 2200mA) has a six month warranty - effective from the purchase date. Do not use any another type of battery on this portable monitor as it may cause a fire or explosion.

• The battery could be damaged if a short circuit is present at the connecting port, or if the polarity of the power cable is reversed.

• When supplying power to the camera via the test monitor, always use the enclosed power harness

(DC Jack).

• When supplying power, connect the power cable to the camera and then apply power. Otherwise, a short circuit might be induced which automatically switches the unit off to protect the battery. If a short is produced, turn the monitor off, remove and re-insert the power harness (DC Jack). Then turn the unit on again.

• Keep the unit inside the carry bag to protect the LCD screen from scratches.

• Do not put the monitor on, or near, anything electrically conductive or expose the unit to rain or moisture.

• Immediately switch the product off if it emits smoke, makes an abnormal noise or emits strange odours.

• If the unit is not working properly, please contact your distributor. Please do not disassemble the unit yourself as it will invalidate the warranty.

Hybrid Portable Test Monitor 3

4

1. Introduction

1-1. Overview

The SD107HY is a multi-functional Analogue / HD-SDI / HDMI portable test monitor. It can be used for various purposes, including checking video signals, the cabling status (has a built-in HDSDI / Analogue video signal level meter, adjusting camera angle of view and focusing, supplying power to camera, controlling a speed dome camera and generating color pattern to the monitor.

1-2. Features

• 7-Inch Wide TFT-LCD Digital LED Backlit Panel

• Various inputs: HD-SDI (3G), HDMI (1080 p60), VGA (1600 x1200), CVBS

• Various Outputs: HD-SDI (3G, Loop Through), CVBS (Loop Through)

• HD-SDI and Analogue Video Signal Level Meter

• HD-SDI Focus Meter

• PTZ control via RS-485 communication for speed dome cameras

• Coaxial communication (Up the Coax). Controls camera OSD menu/PTZ over coax cable (Max. 800m)

• Supply power to the camera (DC12V / 500mA)

• HD-SDI, HDMI Audio Output (Optional)

• Leather bag and strap

• Li-polymer battery (6~8 hours of use)

1-3. Applications

• Display video signals or adjust camera angles.

• Check the cable status and/or DVR.

• Check speed dome cameras, PTZ camera status or control PTZ.

• Control the OSD menu of a camera which supports coax communication.

• Check HD-SDI, HDMI Signals.

• Check the distance at which HD-SDI Repeaters & Receivers should be installed.

• Check DVR VGA outputs

• Test and install POC (Power over Coax) Camera (HD-SDI, CVBS) (Optional)

2. Components

Main Unit Leather Bag

& Shoulder Strap

Accessories

Charger &

Power Cord

Power Harness

 

Hybrid Portable Test Monitor

3. Product Parts and Peripheral Device Connection

3-1. Part Names and Functions

1 2 3 4 5 6 7 8 9 10

No.

1

8

9

10

2

3

4

5

6

7

Marking

12V

RS-485

Function

Charge the Built-In Li-Polymer Battery (with Included Charger) or, Supply Power to the Camera (DC12V/500mA) via Power

Harness.

RS-485 Communication for PTZ Receiver and Speed Dome

Camera

HDMI Signal Input (Max. 1920 x 1080p60Hz) HDMI INPUT

HD-SDI INPUT HD-SDI Signal Input (Max. Resolution : ~3G ) Power Output

(When Using Power Over Coax Feature)

OUTPUT HD-SDI Signal Output (Loop Through)

VGA INPUT

TERM

UXGA Input (Max. Resolution: 1600 x1200)

With Loop Through Output: HI-Z Position

VIDEO

INPUT CVBS Video Signal Input Coaxial Communication: PTZ Receiver or Speed Dome Camera Power Output (When Using Power

Over Coax Feature)

OUTPUT CVBS Video Signal Output (Loop Through)

Outputs Full Colour Bar (Pattern Generator)

POWER Power Switch (ON/OFF)

Hybrid Portable Test Monitor 5

3-1-2. Buttons for Each of the Functions

3 5

HDMI

16:9

1920 X 1080p60

VP : Link Check

16 : 9

1920X1080p60

4

S.LVL: 90% Good

FOCUS: 100 / 100

6

1

1 2

Level Meter Indicator

• S.LVL: Indicates the video signal level of HD-SDI as a percentage.

• FOCUS: Indicates the focusing status for HD-SDI video as a percentage.

• A. LEVEL: Indicates the brightness level of the video (Amplitude/Sync level) as a percentage

• F. LEVEL: Indicates the colour level of the video (Frequency/Burst level) as a percentage.

2 Menu Operation Buttons

Button Camera Menu

MODE

EXIT

MENU

ESC

Multi-Way

Key

ENTER

Key

Up, Down,

Right, Left

ENTER

RS-485 & Coax

Mode

PTZ&OSD Mode

Switch

Operate in PTZ

Mode

Operate in OSD

Mode

Operate in OSD

Mode

Pan/Tilt/Zoom/Focus

Angle Guide

Angle Mode Out

Up, Down,

Right, Left

Select Bar

Video Input

Source Change

Hot Key

(Zoom in)

Menu ON

Menu OFF

Long: VP ON/

OFF

Hybrid Portable Test Monitor

3 Video Status

• Input Mode: HD-SDI, HDMI, VGA, CVBS

• Display Mode: 4:3, Full (16:10), 16:9, Zoom1, Zoom2

• Input Resolution: 1920 x 1080p60 , NTSC , PAL

4 Battery Status

• There are seven steps indicating battery status. 090% 070% 050%

5 POC (Power Over Coax) device connection indicator.

3-1-2-1. Level Meter Indicator

HD-SDI Level Meter

• S. Level: Indicates HD-SDI signals as a percentage.The closer to 100%, the better the quality of the video; and the lowest Video level is 27%.

Hybrid Portable Test Monitor 7

CVBS Level Meter

• A. Level: Indicates the brightness of the video (Amplitude/Sync level) as a percentage. The closer to

100%, the better the quality of the video. When the A.Level % is under 100%, it indicates the video signals are decreased and the brightness is reduced.

• F. Level: Indicates the colour level of the video (Frequency/Burst level) as a percentage. The closer to

100%, the better the quality of the video colour and the resolution.

• The video level meter indicates the sync and burst level of CVBS video signals in A.Level and F.Level respectively.

Focus Meter for HD-SDI Camera and Focus Meter

• Focus Meter: Indicates the HD-SDI or Analogue Camera Focus as a percentage.

• Shows the focus level (Min. 20% to Max. 255%) and outputs high frequency sounds to the speaker

(Optional), depending on the level.

8 Hybrid Portable Test Monitor

3-2. Connection Diagram

※ Only use the included power harness cable when supplying power to a camera.

3-2-1. HD-SDI Input

• Connect to HD-SDI camera / output the power to camera using power over coax feature. (Input data bitrate: ~3G)

• Outputs power (DC24V) to HD-SDI VP (Video + Power) camera or HD-SDI VP device

3-2-2. HD-SDI Loop through Output

• Output the HD-SDI signal input from the HD-SDI camera (Output data bitrate: ~3G)

3-2-3. Analogue Video Input

• Connect to Analogue Camera

• Output the power (DC12V/500mA) to camera using power over coax feature.

• Using Coax communication feature (Coaxitron), it is possible to control the camera OSD menu or a

PTZ Speed Dome camera via coaxial cable.

3-2-4. Analogue Video Loop Through Output & Pattern Signal Output

• When Pattern Out is OFF, V.OUT port outputs the video received from Analogue camera.

• Select Pattern Out ON, V.OUT port outputs Full Colour Bar to check the wiring status, monitor, DVR, etc.

3-2-3. VGA Input

• Connect to DVR or Computer and UXGA is supported at maximum resolution; higher resolutions may not be displayed normally.

3-2-7. HDMI Input

• Connect to DVR, Computer or other device which outputs HDMI signal. (Resolution: ~1080p 60Hz)

Hybrid Portable Test Monitor 9

3-2-4. PTZ & OSD Control Through RS-485

• Connect to PTZ Receiver and/or Speed Dome Camera as a controller. Also, connect to controller as a PTZ receiver to check if the controller outputs data accurately.

※ Power over coax feature (Video+Power) for HD-SDI & Analogue VP camera and VP

transmission devices.

• Using the Power Over Coax feature of the Hybrid Test monitor, it’s possible to supply power to VP

(Video+power) analogue and HD-SDI cameras via coaxial cable.

• POC (Power Over Coax) feature for HD-SDI VP camera (Optional): When it’s necessary to use the Power POC (Power Over Coax) feature, for installation and maintenance of a HD-SDI VP camera or other HD-SDI VP Transmission product, press and hold the ‘Enter’ key for 3 seconds or more, and the VP feature is activated; after detecting if the device automatically supports the POC feature.

• Power Over Coax feature for Analogue VP camera (Optional): When it’s necessary to use the

Power POC (Power Over Coax) feature, for installation and maintenance of an analogue VP camera or other VP Transmission product, press and hold the ‘Enter’ key for 3 seconds or more, and the VP feature is activated; after detecting if the device automatically supports the POC feature.

4. Menu Setting

4-1. MENU Mode

4-1-1. SELECT MENU

• Press MENU Button and main menu is displayed, as shown below.

• Press the directional buttons to move Up , Down , Right or Left .

The menu mode is automatically switched off if you don’t press any buttons for a few minutes.

 

 

10

4-1-1-1. PICTURE SET

 

 

Hybrid Portable Test Monitor

• Contrast: To adjust the contrast range (0~100 steps)

• Brightness: To adjust the brightness (0 ~ 100 steps)

• Hue: To adjust the colour (0 ~ 100 steps)

• Saturation: To adjust the chroma (0 ~ 100 steps)

• Picture Mode: Standard > Movie > Vivid > User

The value of each mode changes automatically

• Scale: To adjust the screen ratio (Full > 4:3 > Zoom1 > Zoom2 > 16:9)

• Reverse: To reverse the upper and lower sides of the LCD screen.

4-1-1-2. ANGLE MODE

Indication lines: To adjust the viewing angles based on a specific area.

   

• Selecting ANGLE MODE displays a green box and the camera angle zone indication lines.

• Press the SET MENU button to select the size of the green box. Press the SET MENU button again

 

  and select the side lines of the box you want to adjust, and press the / / / buttons to set the position of each line.

• To exit ANGLE MODE, press the EXIT KEY.

4-1-1-3. RS485 & COAX MODE (PTZ / OSD Control)

• MODE: In RS-485 Tx and COAX mode you can control the PTZ & Camera OSD. In Rx. mode, it receives the PTZ control data (as HEX values) and displays the data on the monitor. In Analyser mode, it analyses the protocols received through the RS-485 port and displays the HEX value and command.

• PROTOCOL: To select the protocol of the equipment which you want to control.

• ADDRESS: To select the address of the equipment which you want to control.

※ In COAX mode, you can control the camera regardless of the address

• BAUDRATE: To select the communication speed (2400, 4800, 9600, 19200, 38400).

※ In COAX mode, you can control the camera regardless of the baud rate

• START: To start controlling the device after setting all the above menus.

• EXIT: To exit from MENU MODE

Hybrid Portable Test Monitor 11

12

※ Built-in Protocols:

No.

Company Protocol Product Model

01 DONGYANG

UNITECH

(OSD)

D-MAX

FineSystem

VRX-2201

Honeywell

LG MultiX

DSC-300S/270S/230S

Series (High Speed PTZ Dome Camera)

DOH-240S Series

(Speed PTZ Dome Camera)

DPC-200

(Mini PTZ Dome camera)

DRX-500, DRX-502A (CCTV PTZ receiver)

DY-255RXC 02

03

04

DONGYANG

ELECTRONICS

FINE SYSTEM

INTER-M

05 HONEYWELL (OSD)

06 LG MultiX (OSD)

21

22

23

17

18

19

20

14

15

16

07 LG LPT-A100L

08 PANASONIC (OSD)

09

10

11

12

PANASONIC

PELCO (OSD)

PELCO (OSD)

SAMSUNG

ELECTRONICS

(OSD)

13 SAMSUNG

TECHWIN (OSD)

SUNGJIN

SYSMANIA

VICON

VICON

IKEGAMI

IKEGAMI

NEW BORN

HIGHTECH

TOKINA

ERNITEC (OSD)

BOSCH

DY-255RXC

LG LPT-A100

PanasonicC

PanasonicN

Pelco-D

Pelco-P

Samsung

Techwin

Sungjin

Sysmania

Vicon Stn

Vicon Ext

Ikegami35

Ikegami358

NEWBORN

CRR-1600i/s

VRX-2201

HRX-2000, ScanDome-Ⅱ

LPTEP551PS/

EI551PS/OS551HQ/OI551HQ/OI511HQ

LPT-A100L

CS600, CS650, CS564, CS85X,…

CS564CS854/A,…

Genie ASD, Genie NSD

Genie ASD, Genie NSD

SCC-641/3/07,…, SCC-64x Series

SPD-xxxx Series

RECEIVER/MPU

ORX-1000

V1311RB,V1310RB, V1200R-LM, etc. receivers

Surveyor Dome Series

PCS-35

PCS-358

TOKINA DMP

ERNA

Bosch OSRD

BDR-51x,BDR-55x,BDR-575,ICU

Receiver/Drivers, G1, G2, G3, VEZ, and G4 Series

AutoDomes

24 GSP SYSTEMS CYBERSCAN1

25

26

HITRON

YUJIN SYSTEMS

Fastrax II

Yujin Sys.

27 DYNACOLOR DSCP Dyna. DSCP

28 LADON Ladon

Fastrax II (HID-2404)

EPT-5000S/6000S dynacolor DH801, DH701 and DH600

29

30

31

32

HANIL STM

LILIN_MLP2

LILIN_FastDome

AMERICAN

DYNAMICS

MCU-1200N

LILIN_MLP2

LILIN Fast

MCU-1200N, 1400N, 1500N

AD SpdDome

The protocols marked with ‘(OSD)’ are available to controlling CAMERA OSD Menu.

Hybrid Portable Test Monitor

4-1-1-4-1. RS-485 (TX)

• Displays the current setting mode at the top of the screen.

• Press SET KEY in MULTI WAY KEY selection to select PAN/TILT or ZOOM/FOCUS mode.

- RED: P.T.Z MODE - BLUE: OSD MODE

• Press the Mode KEY to select CAMERA OSD control mode.

• Press the MENU KEY to control CAMERA OSD and press the ESC KEY to exit OSD MENU.

• In case of BOX/DOME Camera, hold the ENTER KEY to select the OSD Menu.

• Press EXIT KEY to go to the previous mode

• (in CAMERA OSD mode, switch to PAN/TILT mode first, in order to exit).

 

  • Press / / / buttons following the OSD guidance on the screen.

※ Caution

• The Hybrid Test monitor has two different PELCO-D Protocols, which are PELCO-D PROTOCOL,

PELCO (CNB).

• For PELCO-D PROTOCOL, it is possible to enter the camera OSD menu by using MENU key.

(SET PRESET COMMAND)

• For PELCO (CNB) PROTOCOL, it is possible to enter the camera OSD menu by using MENU key

(Go to PRESET) or ESC key (Run PRESET)

• Depending on the camera manufacturer, the command to enter the camera OSD Menu is different.

4-1-1-4-2. RX

• Displays the current setting mode at the top of the screen.

• Displays the connection status of the RS-485 line indicated by a HEX value.

• The received data via the RS-485 port is displayed as a maximum in 8 lines in bytes (16 byte).

• When the data is more than 128 byte, it’s cleared out automatically. You can also clear it out temporarily, using the ESC button.

• To go to the previous menu, press the EXIT button.

Hybrid Portable Test Monitor 13

4-1-1-4-3.COAX [UP THE COAX] Control

• Displays the current setting mode at the top of the screen.

• Press the SET KEY in MULTI WAY KEY selection to select PAN/TILT mode or ZOOM/FOCUS mode.

- RED: P.T.Z MODE - BLUE: OSD MODE

• Press the Mode KEY to select the CAMERA OSD control mode.

• Press the MENU KEY to control the CAMERA OSD, and the ESC KEY to exit OSD MENU.

For BOX/DOME Cameras, Hold the ENTER KEY to select OSD Menu

• Press the EXIT KEY to go to the previous mode. In CAMERA OSD mode, switch to PAN/TILT mode first in order to exit.

• Press / / / buttons following the OSD guidance on the screen.

• List of controllable models

No.

Company

01 Samsung Techwin

02 Pelco

03 Dongyang Unitech

04 Samsung E

Protocol

PELCO-C

PELCO-C

PELCO-C

A1

Product Model

All models to support

COAX communication (WINNER 5)

All models to support

COAX communication

All models to support

COAX communication (PIXIM)

All models to support

COAX communication

※ PELCO-C PROTOCOL in Hybrid Test monitor is compatible with all the product models above.

Also, this product can control COAX in a remote side through the automatic NTSC/PAL recognition without any set-up.

4-1-1-4-4. ANALYSER

• Using Analyser mode, the test monitor recognises the received data packet and displays the address and command.

14

• Addr: Show the address.

• Cmd: Show the command

• Packet: Show the Hex code of the received data.

Hybrid Portable Test Monitor

4-1-1-5. PATTERN SET

• Basically outputs the input signals through the Video Out BNC. But if you select “ON” on the CVBS

Out in the pattern set menu, the selected pattern is output from the Video Out BNC.

• It is possible to select one of ten pattern types.

 

4-1-1-6. LEVEL METER & FOCUS METER

• CVBS Level Meter can be ON/OFF.

• HD-SDI Level Meter can be ON/OFF.

• HD-SDI Focus Meter can be ON/OFF.

Hybrid Portable Test Monitor 15

4-1-1-7. SYSTEM SET

• To set the System

• Language: KOR / ENG / JAP

• OSD Dwell Time: To set the time to turn the monitor menu OFF

• BACK LIGHT: To adjust the brightness of the LED Monitor.

• Setting Initialisation: To initialise all settings.

• Version: To display the product Firmware version and the date.

16 Hybrid Portable Test Monitor

5. Specification

LCD

VIDEO

DISPLAY RESOLUTION

SIZE

PIXEL PITCH

BRIGHTNESS (cd)

CONTRAST RATIO

Viewing

Angle

Horizontal

Vertical

RESPONSE (ms)

INPUT HDMI

HD-SDI

CVBS

XVGA

OUTPUT CVBS PATTERN ON

Indication range for

CVBS video signal level

PATTERN

OFF

VIDEO OUT

HDSDI VIDEO OUT

A LEVEL

F LEVEL

ERROR RATE

RANGE FOR

HD-SDI SIGNAL

LEVEL

SDI LEVEL

FOCUS LEVEL

ERROR RATE

CONNECT PORT HDMI INPUT

HD-SDI INPUT

HD-SDI OUTPUT

VGA INPUT

CVBS VIDEO INPUT

CVBS VIDEO OUTPUT

RS-485

POWER

POWER

CONSUMPTION

INPUT

OUTPUT

COLOUR

BATTERY

With HDMI input

With HD-SDI input

With VGA Input

With CVBS Input

VP On

TEMPERATURE

HUMIDITY

WEIGHT

DIMENSIONS (excluding the bag)

SD107HY Hybrid Test Monitor

1280 X (RGB) X 800

6.95 inch (Diagonal)

0.117mm (H) X 0.177mm (V)

Min.:340, Nor.:400

Min.:600, Nor.:800

89°

89°

11

~1080p 60

~3G PoC Output (DC24V)

NTSC/PAL 1.0Vp-p PoC Output (DC24V)

Max. 1600x1200, 60Hz

Colour Bar

Loop Through Output

NTSC/PAL 1.0Vp-p (75 Ω)

~3G, LOOP THROUGH

10 ~ 118%

20 ~ 120%

±2%

10 ~ 100%

10 ~ 100%

-

HDMI C Type F

BNC-F

BNC-F

D-SUB 15-Pin RIGHT ANGLE TYPE

BNC-F

Pan/Tilt/Zoom/Focus

Control

BNC-F

OSD Control

DC 12.6V (exclusive Adapter included)

DC 12V

Dark Grey

2x Li-Polymer: 11.1V, 2200mA (protection circuit applied)

6.5W

7.5W

6.5W

6.5W

Different depending on camera

(Do not use PTZ Cameras)

0℃ ~ +50℃

0% ~ 80%

SET : 920g , BAG : 640g Total : 1.6kg

240.9 (w) X 153.4 (h) X 50 (d)mm

Hybrid Portable Test Monitor 17

GENIE CCTV LTD.

CCTV House, City Park, Watchmead, Welwyn Garden City, Hertfordshire, AL7 ILT

Tel: +44 (0) 1707 330541 Fax: +44 (0) 1707 330543 www.geniecctv.com

Edition. GN-March 2013

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement