A7AX.book 1 ページ 2005年9月22日 木曜日 午後7時40分

INVERTER

Plug-in option

FR-A7AX

INSTRUCTION MANUAL

16 bit digital input function

PRE-OPERATION INSTRUCTIONS

INSTALLATION AND WIRING

CONNECTION DIAGRAM AND TERMINAL

PARAMETERS

1

2

3

4

A7AX.book 1 ページ 2005年9月22日 木曜日 午後7時40分

Thank you for choosing this Mitsubishi Inverter plug-in option.

This instruction manual gives handling information and precautions for use of this equipment. Incorrect handling might cause an unexpected fault. Before using the equipment, please read this manual carefully to use the equipment to its optimum.

Please forward this manual to the end user.

This section is specifically about safety matters

Do not attempt to install, operate, maintain or inspect this product until you have read through this instruction manual and appended documents carefully and can use the equipment correctly. Do not use this product until you have a full knowledge of the equipment, safety information and instructions.

In this instruction manual, the safety instruction levels are classified into "WARNING" and "CAUTION".

WARNING

CAUTION

Assumes that incorrect handling may cause hazardous conditions, resulting in death or severe injury.

Assumes that incorrect handling may cause hazardous conditions, resulting in medium or slight injury, or may cause physical damage only.

Note that even the

CAUTION

level may lead to a serious consequence according to conditions. Please follow the instructions of both levels because they are important to personnel safety.

SAFETY INSTRUCTIONS

1. Electric Shock Prevention

WARNING

While power is on or when the inverter is running, do not

open the front cover. You may get an electric shock.

Do not run the inverter with the front cover or wiring cover

removed. Otherwise, you may access the exposed highvoltage terminals and charging part and get an electric shock.

If power is off, do not remove the front cover except for wiring

or periodic inspection. You may access the charged inverter circuits and get an electric shock.

Before starting wiring or inspection, check to make sure that

Indication of the inverter operation panel is off, wait for at least

10 minutes after the power supply has been switched off, and check that there are no residual voltage using a tester or the like. The capacitor is charged with high voltage for some time after power off and it is dangerous.

Any person who is involved in the wiring or inspection of this

equipment should be fully competent to do the work.

Always install the plug-in option before wiring. Otherwise,

you may get an electric shock or be injured.

Do not touch the plug-in option with wet hands. Otherwise

you may get an electric shock.

Do not subject the cables to scratches, excessive stress,

heavy loads or pinching. Otherwise you may get an electric shock.

A-1

A7AX.book 2 ページ 2005年9月22日 木曜日 午後7時40分

2. Injury Prevention

CAUTION

Apply only the voltage specified in the instruction manual to

each terminal. Otherwise, burst, damage, etc. may occur.

Ensure that the cables are connected to the correct terminals.

Otherwise, burst, damage, etc. may occur.

Always make sure that polarity is correct to prevent damage, etc.

Otherwise, burst, damage may occur.

While power is on or for some time after power-off, do not touch

the inverter as it is hot and you may get burnt.

3. Additional Instructions

Also note the following points to prevent an accidental failure, injury, electric shock, etc.

1) Transportation and mounting

CAUTION

Do not install or operate the plug-in option if it is damaged or

has parts missing.

Do not stand or rest heavy objects on the product.

Check that the mounting orientation is correct.

Prevent other conductive bodies such as screws and metal

fragments or other flammable substance such as oil from entering the inverter.

2) Trial run

CAUTION

Before starting operation, confirm and adjust the parameters.

A failure to do so may cause some machines to make unexpected motions.

3) Usage

WARNING

Do not modify the equipment.

Do not perform parts removal which is not instructed in this

manual. Doing so may lead to fault or damage of the inverter.

CAUTION

When parameter clear or all parameter clear is performed,

reset the required parameters before starting operations.

Each parameter returns to the initial value.

For prevention of damage due to static electricity, touch

nearby metal before touching this product to eliminate static electricity from your body.

4) Maintenance, inspection and parts replacement

CAUTION

Do not test the equipment with a megger (measure insulation

resistance).

5) Disposal

Treat as industrial waste.

CAUTION

6) General instruction

All illustrations given in this manual may have been drawn with covers or safety guards removed to provide in-depth description. Before starting operation of the product, always return the covers and guards into original positions as specified and operate the equipment in accordance with the manual.

A-2

A7AX.book 1 ページ 2005年9月22日 木曜日 午後7時40分

1

PRE-OPERATION INSTRUCTIONS

CONTENTS

1.1

Unpacking and Product Confirmation .............................................................................................1

1.1.1

Packing confirmation ...................................................................................................................................... 1

1.1.2

Parts ............................................................................................................................................................... 2

1.1.3

Specifications ................................................................................................................................................. 3

2

INSTALLATION AND WIRING 4

1

2.1

Pre-Installation Instructions .............................................................................................................4

2.2

Installation Procedure .......................................................................................................................5

2.3

Wiring..................................................................................................................................................7

3

CONNECTION DIAGRAM AND TERMINAL 9

3.1

Connection Diagram..........................................................................................................................9

3.2

Internal Block Diagram....................................................................................................................11

3.3

Terminals ..........................................................................................................................................12

3.4

Code Input Example ........................................................................................................................13

4

PARAMETERS 14

4.1

Parameter List ..................................................................................................................................14

4.2

Parameter Setting ............................................................................................................................16

4.2.1

Selection of input method (Pr. 304) .............................................................................................................. 16

4.2.2

Data read timing signal on-off selection (Pr. 305) ........................................................................................ 18

4.2.3

Bias and gain adjustment (Pr. 300, Pr. 301, Pr. 302, Pr. 303) ..................................................................... 20

4.2.4

Digital input increments selection (Pr. 329) .................................................................................................. 22

4.2.5

16 bit digital torque command (FR-A700 series only) .................................................................................. 23

4.3

Instructions ......................................................................................................................................27

A7AX.book 1 ページ 2005年9月22日 木曜日 午後7時40分

1

PRE-OPERATION INSTRUCTIONS

1.1

Unpacking and Product Confirmation

Take the plug-in option out of the package, check the unit name, and confirm that the product is as you ordered and intact.

This product is a plug-in option dedicated for the FR-A

700

/F

700

series.

1.1.1

Packing confirmation

Check the enclosed items.

Plug-in option

......................................... 1

Mounting screw (M3

× 6mm)

.............. 2 (Refer to page 5.)

Hex-head screw for option mounting (5.5mm)

............... 1 (Refer to page 5.)

5.5mm

1

1

A7AX.book 2 ページ 2005年9月22日 木曜日 午後7時40分

PRE-OPERATION INSTRUCTIONS

1.1.2

Parts

Terminal block

Front view

Mounting hole

Rear view

2

Mounting hole

Terminal layout

X10

X11

X12

X13

X14

X15

DY

X5

X6

X7

X8

X9

X0

X1

X2

X3

X4

Connector

Connect to the inverter option connector

(Refer to page 5.)

Mounting hole

A7AX.book 3 ページ 2005年9月22日 木曜日 午後7時40分

1.1.3

Specifications

(1) Digital input signal type

BCD code 3 digits or 4 digits

Binary 12 bits or binary 16 bits

(2) Selection of digital input signal

Select from the operation panel or parameter unit.

(3) Input current

5mA(24VDC) for each circuit

(4) Input specifications

Contact signal or open collector input

(5) Adjustment function

⋅ Bias and gain

⋅ Analog compensation input

(Set using the operation panel)

PRE-OPERATION INSTRUCTIONS

1

3

A7AX.book 4 ページ 2005年9月22日 木曜日 午後7時40分

2

INSTALLATION AND WIRING

2.1

Pre-Installation Instructions

Make sure that the input power of the inverter is off.

CAUTION

With input power on, do not install or remove the plug-in option. Otherwise, the inverter and plug-in option may be damaged.

4

A7AX.book 5 ページ 2005年9月22日 木曜日 午後7時40分

INSTALLATION AND WIRING

2.2

Installation Procedure

1) Remove the inverter front cover.

1)

2) Mount the hex-head screw for option mounting into the inverter screw hole (on earth plate). (size 5.5mm, tightening torque 0.56N

⋅m to 0.75N⋅m)

2)

3)

Screw hole for option mounting

Inverter side option connector

3) Securely fit the connector of the plug-in option to the inverter connector along the guides.

4) Securely fix the both right and left sides of the plug-in option to the inverter with the accessory mounting screws. If the screw holes do not line-up, the connector may not have been plugged snugly.

Check for loose plugging.

Screw hole for option mounting

(on earth plate)

Hex-head screw for option mounting

4)

Mounting

screws

REMARKS

After removing two screws on the right and left places, remove the plug-in option.

(When the plug-in option is mounted in the connector 3 (connector 1 for the FR-F

700

series), it is easier to remove the plug-in option after removing a control circuit terminal block.)

2

5

A7AX.book 6 ページ 2005年9月22日 木曜日 午後7時40分

INSTALLATION AND WIRING

CAUTION

When two or more options are mounted, priority is in order of inverter option connectors 1, 2 and 3, the options having lower priority are inoperative.

When the inverter cannot recognize that the option is mounted due to improper

Mounting Error installation, etc., " to " (option alarm) are displayed for the FR-

A700 series.The errors shown differ according to the mounting positions

Position Display

(connectors 1, 2, 3).

Connector 1

Connector 2

Connector 3

The FR-F700 series has one connection connector for the plug-in option. When the inverter can not

recognize that the option unit is mounted due to improper installation, etc., " " (option alarm) is displayed.

Take care not to drop a hex-head screw for option mounting or mounting screw during mounting and removal.

Pull out the option straight to remove. Otherwise, the connector may be damaged by some applied force.

6

A7AX.book 7 ページ 2005年9月22日 木曜日 午後7時40分

INSTALLATION AND WIRING

2.3 Wiring

(1) Strip off the sheath of the cable to wire.

Strip off the sheath about the size below. If the length of the sheath pealed is too long, a short circuit may occur among neighboring wires. If the length is too short, wires might come off.

Cable stripping size

Wire the stripped cable after twisting it to prevent it from becoming loose.

In addition, do not solder it.

Use a bar type terminal as required.

5mm

REMARKS

Information on bar terminals

Introduced products (as of October, 2003): Phoenix Contact Co.,Ltd.

Terminal Screw

Size

Bar Terminal Model

(with insulation sleeve)

Bar Terminal Model

(without insulation sleeve)

M2 Al 0.5-6WH A 0.5-6

⋅ Bar terminal crimping tool: CRIMPFOX ZA3 (Phoenix Contact Co., Ltd.)

Wire Size (mm

2

)

0.3 to 0.5

When using the bar terminal (without insulation sleeve), use care so that the twisted wires do not come out.

(2) Loosen the terminal screw and insert the cable into the terminal.

Screw Size

M2

Tightening Torque

0.22N

⋅m to 0.25N⋅m

Cable Size

0.3mm

2

to 0.75mm

2

Screwdriver

Small flat-blade screwdriver

(Tip thickness: 0.4mm/tip width: 2.5mm )

CAUTION

Undertightening can cause cable disconnection or malfunction. Overtightening can cause a short circuit or malfunction due to damage to the screw or unit.

7

2

A7AX.book 8 ページ 2005年9月22日 木曜日 午後7時40分

INSTALLATION AND WIRING

(3) For wiring of the FR-A

700

series 22K or less and the FR-F

700

series 30K (FR-F720-01250, FR-F740-

00620) or less, route wires between the control circuit terminal block and front cover. If cables can not be routed between the control circuit terminal block and front cover due to the increased number of cables, remove a hook of the front cover and use a space become available.

For wiring of the FR-A

700

series 30K or more and the FR-F

700

series 37K (FR-F720-01540, FR-F740-

00770) or more, use the space on the left side of the control circuit terminal block.

8

Cut off with a nipper, etc.

FR-A

700

series 22K or less and FR-F

700

series 30K or less

Cut off a hook on the inverter front cover side surface.

(Cut off so that no portion is left.)

Control circuit terminal block

FR-A

700

series 30K or more and FR-F

700

series 37K or more

REMARKS

When the hook of the inverter front cover is cut off for wiring, the protective structure (JEM1030) changes to open type

(IP00 (The structure of the NA version is no longer NEMA 1.)).

CAUTION

When performing wiring using the space between the inverter front cover and control circuit terminal block, take care not to subject the cable to stress.

After wiring, wire offcuts must not be left in the inverter. They may cause a fault, failure or malfunction.

A7AX.book 9 ページ 2005年9月22日 木曜日 午後7時40分

3

CONNECTION DIAGRAM AND TERMINAL

3.1 Connection Diagram

Relay contact signal input (sink logic

*3

) Open collector signal input (sink logic

*3

)

Thousand's place

Hundred's place

Ten's place

Unit's place

X15

X14

X13

X12

X11

X10

X9

X8

X7

X6

X5

X4

X3

X2

X1

X0

DY

SD

*1

FR-A7AX

AY41 type transistor output unit

*2

Thousand's place

Hundred's place

Ten's place

Unit's place

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

35

36

X7

X6

X5

X4

X3

X2

X1

X0

X15

X14

X13

X12

X11

X10

X9

X8

FR-A7AX

Inverter

Reading command

*2

DY

PC

*1

Inverter

*1 Use terminals SD or PC on the inverter.

*2 AY41 type unit requires 24VDC power.

Example of connection with the output module (AY41 type) of Mitsubishi PLC. Refer to the output module manual for details of the output module.

*3 The control logic is the same as that of the inverter.

When the logic of the inverter is changed, the option logic also changes. For details of changing the control logic, refer to the inverter manual.

9

3

A7AX.book 10 ページ 2005年9月22日 木曜日 午後7時40分

CONNECTION DIAGRAM AND TERMINAL

REMARKS

1.

As the input signals are at low level, use two parallel micro signal contacts or a twin contact for relay contact inputs to prevent a contact fault.

Micro signal contacts Twin contacts

2.

A transistor of the following specifications should be selected for the open collector signal:

Electrical characteristics of the transistor used

⋅ I c

≥ 10mA

⋅ Leakage current: 100

µ

A maximum

⋅ V

CE

≥ 30V

⋅ If I c

≥ 10mA, V

CE (sat) voltage is 3V maximum

10

A7AX.book 11 ページ 2005年9月22日 木曜日 午後7時40分

3.2 Internal Block Diagram

The following is the internal block diagram of the FR-A7AX.

CONNECTION DIAGRAM AND TERMINAL

Connector Controller

X0

X15

DY

11

3

A7AX.book 12 ページ 2005年9月22日 木曜日 午後7時40分

CONNECTION DIAGRAM AND TERMINAL

3.3 Terminals

X10

X11

X12

X13

X14

X15

DY

X4

X5

X6

X7

X8

X9

X0

X1

X2

X3

Terminal

Location

Terminal

Symbol

Plug-in option

Inverter

Description

X0 to X15

DY

SD

PC

Digital signal input terminal (frequency setting signal terminal)

Input the digital signal at the relay contact or open collector

terminal. (Refer to page 9.)

For the digital signal input, you can choose either the BCD code input or binary input.

BCD code input ..3 digits (999 maximum) or 4 digits (9999 maximum)

Binary input ........binary 12 bits (X0 to X11, FFF

H

maximum) or binary 16 bits (X0 to X15, FFFF

H

maximum)

Data read timing input signal

Used when a digital signal read timing signal is necessary.

Data is read only during the DY signal is on.

By switching the DY signal off, the X0 to X15 data before signal-

off is retained. (Refer to page 18.)

Common terminal (sink)

Common terminal for digital and data read timing signals.

Use terminal SD of the inverter.

External transistor common terminal (sink), common terminal (source)

When connecting the transistor output (open collector output) of a programmable controller (PLC), etc., connect the external power common (+) to this terminal to prevent a fault occurring due to leakage current. When you have selected the source logic, this terminal is used as a common terminal. Use terminal

PC of the inverter.

12

A7AX.book 13 ページ 2005年9月22日 木曜日 午後7時40分

CONNECTION DIAGRAM AND TERMINAL

3.4 Code Input Example

The following explains examples of terminal status and input value at BCD code input and binary input.

Example: when the input value is 6325

BCD Code Input

Digit

1

10

100

1000

Terminal name

X8

X9

X10

X11

X12

X13

X14

X15

X4

X5

X6

X7

X0

X1

X2

X3

Terminal input status

ON

ON

OFF

OFF

OFF

ON

ON

OFF

ON

OFF

ON

OFF

OFF

ON

OFF

OFF

Input value

5

2

3

6

Example: when the input value is AB65

H

Binary Input

Terminal name

Terminal input status

Input value

(hexadecimal)

Input value

(decimal)

X8

X9

X10

X11

X12

X13

X14

X15

X4

X5

X6

X7

X0

X1

X2

X3

ON

ON

OFF

ON

OFF

ON

OFF

ON

ON

OFF

ON

OFF

OFF

ON

ON

OFF

5

6

B

A

43877

CAUTION

For the BCD code input, the input value of each digit is from 0 to 9. When the value greater than 9 is input, it is made invalid and the last value is retained.

13

3

A7AX.book 14 ページ 2005年9月22日 木曜日 午後7時40分

4

PARAMETERS

4.1 Parameter List

When the FR-A7AX is fitted, the following parameters can be set.

The FR-A7AX does not function with the factory setting. When a value other than

"

9999

"

is set in Pr. 304, digital input is enabled.

Set the following parameters according to applications.

Parameter

Number

300

301

302

303

304

305

329

447

*4

448

*4

804

*4

Name

BCD code input bias

BCD code input gain

Binary input bias

Binary input gain

Selection of digital input and analog input compensation enable/disable

Data read timing signal on-off selection

Digital input increments selection

*3

Digital torque command bias

Digital torque command gain

Torque command source selection

Setting Range

0 to 400Hz

0 to 400Hz, 9999

0 to 400Hz

0 to 400Hz, 9999

0 to 4, 10 to 14,

9999

*1

0, 1, 10

0, 1, 2, 3

0 to 400%

0 to 400%, 9999

0, 1, 3 to 6

Initial

Value

0Hz

60Hz

(50Hz)

*2

0Hz

60Hz

(50Hz)

*2

Setting

Increments

0.01Hz

0.01Hz

0.01Hz

0.01Hz

Refer to page

20

21

20

21

9999

0

1

0

150%

0

1

1

1

1%

1%

1

16, 23

18

22

23

23

23

14

A7AX.book 15 ページ 2005年9月22日 木曜日 午後7時40分

PARAMETERS

*1 Setting values "4" and "14" are available with the FR-A700 series only.

*2 The initial value of the EC version is 50Hz.

*3 For Pr. 329, write is disabled during operation even when "2" is set in Pr. 77. When changing the parameter setting, stop the operation. Also parameter clear is made invalid.

*4 These parameters can be set for the FR-A700 series only.

REMARKS

Binary input ............ The input data is taken in hexadecimal

BCD code input...... The input data is taken in decimal

15

4

A7AX.book 16 ページ 2005年9月22日 木曜日 午後7時40分

PARAMETERS

4.2 Parameter Setting

4.2.1

Selection of input method (Pr. 304)

Parameter

Number

304

Name

Selection of digital input and analog input compensation enable/disable

Setting Range

0 to 4,10 to 14,

9999

Pr. 304 Setting

2

3

0

1

4

*2

10

11

12

13

14

*2

9999

(initial value)

Binary Input

12bit

12bit

12bit

Torque command value input

16bit

16bit

16bit

Torque command value input

BCD Code Input

3 digits

3 digits

4 digits

4 digits

No function

Initial

Value

9999

Setting

Increments

1

Availability of Analog

Input Compensation

*1

(

{: enabled, ×: disabled)

×

×

{

{

×

×

{

{

16

A7AX.book 17 ページ 2005年9月22日 木曜日 午後7時40分

PARAMETERS

*1 Use terminal 1 for analog input compensation. Refer to the inverter instruction manual (applied) for details of terminal 1.

*2 These parameters can be set for the FR-A700 series only.

Refer to page 23 for details of torque command value input.

REMARKS

⋅ Signal X12 to X15 become invalid when 0 to 3 are set in Pr. 304.

⋅ Refer to page 13 for BCD code/ binary input example.

17

4

A7AX.book 18 ページ 2005年9月22日 木曜日 午後7時40分

PARAMETERS

4.2.2

Data read timing signal on-off selection (Pr. 305)

Parameter

Number

305

Name

Data read timing signal on-off selection

Setting Range

0, 1, 10

Initial

Value

0

Setting

Increments

1

Pr. 305 Setting

0

(initial value)

1

10

Filter

Without

Without

With

Description

The set frequency data entered from the digital signal input terminals (X0 to X15) is always imported independently of whether the DY signal is on or off.

The set frequency data entered from the digital signal input terminals (X0 to X15) is imported only when the DY signal is on.

The set frequency data is not imported when the DY signal is off.

Therefore, even if the input status of the X0-X15 signal changes, the set frequency data before off of the DY signal is valid.

The set frequency data entered from the digital signal input terminals (X0 to X15) is always imported independently of whether the DY signal is on or off.

The time lag when digital signals change can be compensated with a filter.

When "0 or 10" is set in Pr. 305

Filter (Pr. 305 = "10")

Digital signal input

(terminal X0 to X15)

20ms or more necessary*

Reflected on the set frequency

Set frequency

20ms maximum

* Hold the digital signal input (X0 to

X15) status for 20ms or more.

18

A7AX.book 19 ページ 2005年9月22日 木曜日 午後7時40分

PARAMETERS

z How to use the DY signal (when "1" is set in Pr. 305)

1ms or more

1ms or more

Digital signal input

(terminal X0 to X15)

20ms or more necessary

Data read timing signal

(terminal DY)

OFF ON

REMARKS

When Pr. 305 = "1", each terminal from X0 to X15 is all recognized as off when the inverter is turned on in terminal DY off status.

For example, when bias is set to 20Hz, turning the power supply on in the DY signal off status and then turning on the start signal will make the frequency command valid, starting the inverter to operate at 20Hz. z SERIAL number check

The setting of "10" for Pr. 305 can be used for the FR-A700 series and FR-F700 series 55K (01160 (EC

Version)) or less produced in June 2004 or later. Check the SERIAL number indicated on the inverter rating plate or package.

[SERIAL]

{

4 6

{{{{{{

Symbol Year Month Control number

19

4

A7AX.book 20 ページ 2005年9月22日 木曜日 午後7時40分

PARAMETERS

4.2.3

Bias and gain adjustment (Pr. 300, Pr. 301, Pr. 302, Pr. 303)

Parameter

Number

300

301

302

303

Name

BCD code input bias

BCD code input gain

Binary input bias

Binary input gain

Setting Range

0 to 400Hz

0 to 400Hz, 9999

0 to 400Hz

0 to 400Hz, 9999

Initial

Value

0Hz

60Hz

(50Hz)

*

0Hz

60Hz

(50Hz)

*

Setting

Increments

0.01Hz

0.01Hz

0.01Hz

0.01Hz

* The initial value of the EC version is 50Hz.

(1) Bias adjustment

Bias adjustments can be made for the digital input signal.

Set the set frequency at the digital input of 0.

⋅ BCD code input......Set using Pr. 300.

⋅ Binary input............Set using Pr. 302.

20

A7AX.book 21 ページ 2005年9月22日 木曜日 午後7時40分

PARAMETERS

(2) Gain adjustment

The gain may be set in either of the following two ways:

How to set the output frequency when the input signal is 999 or 9999 (BCD code), and FFF

H

or

FFFF

H

(binary).

⋅ BCD code input .. Set using Pr. 301.

⋅ Binary input ........ Set using Pr. 303.

The output frequency is factory-set to 60Hz (EC version : 50Hz).

Pr.301

Pr.303

Pr.300

Pr.302

0

0

Bias

Digital input signal

Gain

999(9999)

FFF

H

(FFFF

H

)

BCD

Pr.304=0,2

Binary (BIN) Pr.304=1,3

CAUTION

The maximum output frequency for operation with the digital input signal is the "gain" value set in

Pr. 301 and Pr. 303.

To set the maximum output frequency at 60Hz (EC version :

50Hz) or more, change

" gain

"

with the operation panel.

How to set the BCD code or binary value as the output frequency setting

When "9999" is set in Pr. 301 (BCD code) or Pr. 303 (binary), the digital input value is set as the output frequency.

(For example, to set the output frequency to 120Hz when the BCD code input is

"

120

"

)

120

0 120

Digital input signal

(BCD)

REMARKS

When this setting method is used, "bias" setting (Pr. 300 or

Pr. 302) cannot be made.

21

4

A7AX.book 22 ページ 2005年9月22日 木曜日 午後7時40分

PARAMETERS

4.2.4

Digital input increments selection (Pr. 329)

Parameter

Number

329

Name

Digital input increments selection

*1

Setting Range

0, 1, 2, 3

Initial

Value

1

Setting

Increments

1

When "9999" is set in Pr. 301 BCD code input gain or Pr. 303 Binary input gain, the increments when the digital signal is set as output frequency can be set.

Frequency = digital input signal value

× Pr. 329 input increments

Available Frequencies

*1

Pr. 329 Setting

Input Value

Increments

12bit

BCD code

0

1 (factory setting)

10

1

0 to 9990Hz

0 to 999Hz

2 0.1

0 to 99.9Hz

3 0.01

0 to 9.99Hz

*1 These are not the inverter maximum output frequencies.

Binary

0 to 40950Hz

0 to 4095Hz

0 to 409.5Hz

0 to 40.95Hz

BCD code

0 to 99990Hz

0 to 9999Hz

0 to 999.9Hz

0 to 99.99Hz

16bit

Binary

0 to 655350Hz

0 to 65535Hz

0 to 6553.5Hz

0 to 655.35Hz

REMARKS

When the values other than "9999" are set in Pr. 301 or Pr. 303, Pr. 329 is made invalid.

<Example>

Pr. 329 = 0 BCD code = 111

Binary = 100

H

(256 in decimal)

Pr. 329 = 1 BCD code = 111

Binary = 100

H

(256 in decimal)

Pr. 329 = 2 BCD code = 111

Binary = 100

H

(256 in decimal)

Pr. 329 = 3

BCD code = 111

Binary = 100

H

(256 in decimal)

1110Hz

2560Hz

111Hz

256Hz

11.1Hz

25.6Hz

1.11Hz

2.56Hz

22

A7AX.book 23 ページ 2005年9月22日 木曜日 午後7時40分

PARAMETERS

4.2.5

16 bit digital torque command (FR-A700 series only)

Parameter

304

447

448

804

Name

Selection of digital input and analog input compensation enable/disable

Digital torque command bias

Digital torque command gain

Torque command source selection

Setting Range

0 to 4, 10 to 14, 9999

0 to 400%

0 to 400%, 9999

0, 1, 3 to 6

Initial Value Increments

9999

0

150%

0

1

1%

1%

1

Digital torque command can be given under torque control using the FR-A7AX .

A digital command using the FR-A7AX can be given when "4 (12 bit)" or "14 (16 bit)" is set in Pr.304 and "4" is set in Pr.804 Torque command source selection.

Pr.804

parameter setting

0

1

Description

Torque command by terminal 1 analog input

Torque command by parameter setting

Setting value of Pr.805 or Pr.806 (-400% to 400%)

Remarks

Refer to the inverter manual for details.

3

4

5

6

Torque command by CC-Link communication (FR-A7NC)

12 bit digital input (FR-A7AX)

16 bit digital input (FR-A7AX)

Refer to the inverter manual for details.

Torque command by CC-Link communication (FR-A7NC)

Refer to the instruction manual of the

FR-A7NC for details.

When "4" is set in Pr. 304

When "14" is set in Pr. 304

Refer to the instruction manual of the

FR-A7NC for details.

23

4

A7AX.book 24 ページ 2005年9月22日 木曜日 午後7時40分

PARAMETERS

The input signal uses the last 15 (11) bits as torque command and the most significant bit as sign.

When 16 bit is selected

Bit15 Bit0 sign bit

0: positive, 1: negative

0 to 7FFF

H

or 0 to 190

H

(400)

REMARKS

The digital torque command is input only by binary input.

24

A7AX.book 25 ページ 2005年9月22日 木曜日 午後7時40分

PARAMETERS

z Input method of torque command

Torque command may be input in either of the following two ways:

(1) Method to define the torque command value for the input command by setting the torque command value when the input signal is 0 and plus side torque command value when the input signal is 7FFF

H

(7FF

H

) as shown in the graph

Set the torque command value when the input signal is "0" in Pr.447 and the torque command value when the input signal is "7FFF

H

(7FF

H

) in Pr.448 .

Torque command value

Pr.448

150%

Initial value

7FFF

H

(7FF

H

)

0

Pr.447

7FFF

H

(7FF

H

)

Digital input signal

Most significant bit = 1

-150%

Most significant bit = 0

25

4

A7AX.book 26 ページ 2005年9月22日 木曜日 午後7時40分

PARAMETERS

(2) Method to directly input the torque command value as numeral value in digital

When "9999" is set in Pr.448, the input signal is considered as a torque command value.

Even if a value higher than 190H (400) is input, the torque command value is clamped at 400%.

Torque command value

400%

7FFF

H

(7FF

H

)

190

H

(400)

Most significant bit = 1

0

190

H

(400)

-400%

Most significant bit = 0

7FFF

H

(7FF

H

)

Digital input signal

26

A7AX.book 27 ページ 2005年9月22日 木曜日 午後7時40分

PARAMETERS

4.3 Instructions

(1) Acceleration/deceleration time

When the frequency is set with the digital input signal, the acceleration/deceleration time is the period of time required to reach the Acceleration/deceleration reference frequency set in Pr. 20. This is the same as when using the analog signal input.

(2) There are the following restrictions on the digital input signal:

When the signal is used to enter a BCD code, 0A

H

to 0F

H

entries are ignored during operation and the previous inputs are used to continue operation.

If binary input is changed to BCD code input with 0A

H

to 0F

H

input, the set frequency becomes 0Hz.

(3) If 0 to 5V (0 to 10V) is input at the inverter terminal 1 from the external volume with the FR-A7AX fitted, the inverter operates at the frequency obtained by adding the FR-A7AX BCD code input and the compensation input from terminal 1 only when

"

2, 3, 12 or 13

"

is set in Pr. 304.

When switching the inputs e.g. between volume input to perform manual operation and BCD code input to perform automatic operation, set the BCD code input to "0" under manual operation.

(4) The priorities of the frequency setting are as follows.

JOG>Multi-speed operation (RH, RM, RL) >PID (X14) >AU (terminal 4) >Digital command by the FR-

A7AX > terminal 2

"

(When digital input is valid, terminal 2 is invalid.)

27

4

A7AX.book 28 ページ 2005年9月22日 木曜日 午後7時40分

REVISIONS

Print Date *Manual Number

May, 2004 IB(NA)-0600164ENG-A

Sep.,2005 IB(NA)-0600164ENG-B

*The manual number is given on the bottom left of the back cover.

Revision

First edition

Additions

Compatible with the FR-A700 series

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals