INVERTER
Plug-in option
FR-A7AX
INSTRUCTION MANUAL
16 bit digital input function
CONNECTION DIAGRAM AND TERMINAL
1
2
3
4
A7AX.book 1 ページ 2005年9月22日 木曜日 午後7時40分
Thank you for choosing this Mitsubishi Inverter plug-in option.
This instruction manual gives handling information and precautions for use of this equipment. Incorrect handling might cause an unexpected fault. Before using the equipment, please read this manual carefully to use the equipment to its optimum.
Please forward this manual to the end user.
This section is specifically about safety matters
Do not attempt to install, operate, maintain or inspect this product until you have read through this instruction manual and appended documents carefully and can use the equipment correctly. Do not use this product until you have a full knowledge of the equipment, safety information and instructions.
In this instruction manual, the safety instruction levels are classified into "WARNING" and "CAUTION".
WARNING
CAUTION
Assumes that incorrect handling may cause hazardous conditions, resulting in death or severe injury.
Assumes that incorrect handling may cause hazardous conditions, resulting in medium or slight injury, or may cause physical damage only.
Note that even the
CAUTION
level may lead to a serious consequence according to conditions. Please follow the instructions of both levels because they are important to personnel safety.
SAFETY INSTRUCTIONS
1. Electric Shock Prevention
WARNING
• While power is on or when the inverter is running, do not
open the front cover. You may get an electric shock.
• Do not run the inverter with the front cover or wiring cover
removed. Otherwise, you may access the exposed highvoltage terminals and charging part and get an electric shock.
• If power is off, do not remove the front cover except for wiring
or periodic inspection. You may access the charged inverter circuits and get an electric shock.
• Before starting wiring or inspection, check to make sure that
Indication of the inverter operation panel is off, wait for at least
10 minutes after the power supply has been switched off, and check that there are no residual voltage using a tester or the like. The capacitor is charged with high voltage for some time after power off and it is dangerous.
• Any person who is involved in the wiring or inspection of this
equipment should be fully competent to do the work.
• Always install the plug-in option before wiring. Otherwise,
you may get an electric shock or be injured.
• Do not touch the plug-in option with wet hands. Otherwise
you may get an electric shock.
• Do not subject the cables to scratches, excessive stress,
heavy loads or pinching. Otherwise you may get an electric shock.
A-1
A7AX.book 2 ページ 2005年9月22日 木曜日 午後7時40分
2. Injury Prevention
CAUTION
• Apply only the voltage specified in the instruction manual to
each terminal. Otherwise, burst, damage, etc. may occur.
• Ensure that the cables are connected to the correct terminals.
Otherwise, burst, damage, etc. may occur.
• Always make sure that polarity is correct to prevent damage, etc.
Otherwise, burst, damage may occur.
• While power is on or for some time after power-off, do not touch
the inverter as it is hot and you may get burnt.
3. Additional Instructions
Also note the following points to prevent an accidental failure, injury, electric shock, etc.
1) Transportation and mounting
CAUTION
• Do not install or operate the plug-in option if it is damaged or
has parts missing.
• Do not stand or rest heavy objects on the product.
• Check that the mounting orientation is correct.
• Prevent other conductive bodies such as screws and metal
fragments or other flammable substance such as oil from entering the inverter.
2) Trial run
CAUTION
• Before starting operation, confirm and adjust the parameters.
A failure to do so may cause some machines to make unexpected motions.
3) Usage
WARNING
• Do not modify the equipment.
• Do not perform parts removal which is not instructed in this
manual. Doing so may lead to fault or damage of the inverter.
CAUTION
• When parameter clear or all parameter clear is performed,
reset the required parameters before starting operations.
Each parameter returns to the initial value.
• For prevention of damage due to static electricity, touch
nearby metal before touching this product to eliminate static electricity from your body.
4) Maintenance, inspection and parts replacement
CAUTION
• Do not test the equipment with a megger (measure insulation
resistance).
5) Disposal
• Treat as industrial waste.
CAUTION
6) General instruction
All illustrations given in this manual may have been drawn with covers or safety guards removed to provide in-depth description. Before starting operation of the product, always return the covers and guards into original positions as specified and operate the equipment in accordance with the manual.
A-2
A7AX.book 1 ページ 2005年9月22日 木曜日 午後7時40分
PRE-OPERATION INSTRUCTIONS
CONTENTS
INSTALLATION AND WIRING 4
1
CONNECTION DIAGRAM AND TERMINAL 9
PARAMETERS 14
A7AX.book 1 ページ 2005年9月22日 木曜日 午後7時40分
1
PRE-OPERATION INSTRUCTIONS
1.1
Unpacking and Product Confirmation
Take the plug-in option out of the package, check the unit name, and confirm that the product is as you ordered and intact.
This product is a plug-in option dedicated for the FR-A
700
/F
700
series.
1.1.1
Packing confirmation
Check the enclosed items.
Plug-in option
......................................... 1
Mounting screw (M3
× 6mm)
.............. 2 (Refer to page 5.)
Hex-head screw for option mounting (5.5mm)
............... 1 (Refer to page 5.)
5.5mm
1
1
A7AX.book 2 ページ 2005年9月22日 木曜日 午後7時40分
PRE-OPERATION INSTRUCTIONS
1.1.2
Parts
Terminal block
Front view
Mounting hole
Rear view
2
Mounting hole
Terminal layout
X10
X11
X12
X13
X14
X15
DY
X5
X6
X7
X8
X9
X0
X1
X2
X3
X4
Connector
Connect to the inverter option connector
Mounting hole
A7AX.book 3 ページ 2005年9月22日 木曜日 午後7時40分
1.1.3
Specifications
(1) Digital input signal type
BCD code 3 digits or 4 digits
Binary 12 bits or binary 16 bits
(2) Selection of digital input signal
Select from the operation panel or parameter unit.
(3) Input current
5mA(24VDC) for each circuit
(4) Input specifications
Contact signal or open collector input
(5) Adjustment function
⋅ Bias and gain
⋅ Analog compensation input
(Set using the operation panel)
1
3
A7AX.book 4 ページ 2005年9月22日 木曜日 午後7時40分
2
INSTALLATION AND WIRING
2.1
Pre-Installation Instructions
Make sure that the input power of the inverter is off.
CAUTION
With input power on, do not install or remove the plug-in option. Otherwise, the inverter and plug-in option may be damaged.
4
A7AX.book 5 ページ 2005年9月22日 木曜日 午後7時40分
INSTALLATION AND WIRING
2.2
Installation Procedure
1) Remove the inverter front cover.
1)
2) Mount the hex-head screw for option mounting into the inverter screw hole (on earth plate). (size 5.5mm, tightening torque 0.56N
⋅m to 0.75N⋅m)
2)
3)
Screw hole for option mounting
Inverter side option connector
3) Securely fit the connector of the plug-in option to the inverter connector along the guides.
4) Securely fix the both right and left sides of the plug-in option to the inverter with the accessory mounting screws. If the screw holes do not line-up, the connector may not have been plugged snugly.
Check for loose plugging.
Screw hole for option mounting
(on earth plate)
Hex-head screw for option mounting
4)
Mounting
screws
REMARKS
After removing two screws on the right and left places, remove the plug-in option.
(When the plug-in option is mounted in the connector 3 (connector 1 for the FR-F
700
series), it is easier to remove the plug-in option after removing a control circuit terminal block.)
2
5
A7AX.book 6 ページ 2005年9月22日 木曜日 午後7時40分
INSTALLATION AND WIRING
•
•
CAUTION
When two or more options are mounted, priority is in order of inverter option connectors 1, 2 and 3, the options having lower priority are inoperative.
When the inverter cannot recognize that the option is mounted due to improper
Mounting Error installation, etc., " to " (option alarm) are displayed for the FR-
A700 series.The errors shown differ according to the mounting positions
Position Display
(connectors 1, 2, 3).
Connector 1
Connector 2
Connector 3
•
The FR-F700 series has one connection connector for the plug-in option. When the inverter can not
•
•
recognize that the option unit is mounted due to improper installation, etc., " " (option alarm) is displayed.
Take care not to drop a hex-head screw for option mounting or mounting screw during mounting and removal.
Pull out the option straight to remove. Otherwise, the connector may be damaged by some applied force.
6
A7AX.book 7 ページ 2005年9月22日 木曜日 午後7時40分
2.3 Wiring
(1) Strip off the sheath of the cable to wire.
Strip off the sheath about the size below. If the length of the sheath pealed is too long, a short circuit may occur among neighboring wires. If the length is too short, wires might come off.
Cable stripping size
Wire the stripped cable after twisting it to prevent it from becoming loose.
In addition, do not solder it.
Use a bar type terminal as required.
5mm
REMARKS
Information on bar terminals
Introduced products (as of October, 2003): Phoenix Contact Co.,Ltd.
Terminal Screw
Size
Bar Terminal Model
(with insulation sleeve)
Bar Terminal Model
(without insulation sleeve)
M2 Al 0.5-6WH A 0.5-6
⋅ Bar terminal crimping tool: CRIMPFOX ZA3 (Phoenix Contact Co., Ltd.)
Wire Size (mm
2
)
0.3 to 0.5
When using the bar terminal (without insulation sleeve), use care so that the twisted wires do not come out.
(2) Loosen the terminal screw and insert the cable into the terminal.
Screw Size
M2
Tightening Torque
0.22N
⋅m to 0.25N⋅m
Cable Size
0.3mm
2
to 0.75mm
2
Screwdriver
Small flat-blade screwdriver
(Tip thickness: 0.4mm/tip width: 2.5mm )
CAUTION
Undertightening can cause cable disconnection or malfunction. Overtightening can cause a short circuit or malfunction due to damage to the screw or unit.
7
2
A7AX.book 8 ページ 2005年9月22日 木曜日 午後7時40分
(3) For wiring of the FR-A
700
series 22K or less and the FR-F
700
series 30K (FR-F720-01250, FR-F740-
00620) or less, route wires between the control circuit terminal block and front cover. If cables can not be routed between the control circuit terminal block and front cover due to the increased number of cables, remove a hook of the front cover and use a space become available.
For wiring of the FR-A
700
series 30K or more and the FR-F
700
series 37K (FR-F720-01540, FR-F740-
00770) or more, use the space on the left side of the control circuit terminal block.
8
Cut off with a nipper, etc.
FR-A
700
series 22K or less and FR-F
700
series 30K or less
Cut off a hook on the inverter front cover side surface.
(Cut off so that no portion is left.)
Control circuit terminal block
FR-A
700
series 30K or more and FR-F
700
series 37K or more
REMARKS
When the hook of the inverter front cover is cut off for wiring, the protective structure (JEM1030) changes to open type
(IP00 (The structure of the NA version is no longer NEMA 1.)).
CAUTION
When performing wiring using the space between the inverter front cover and control circuit terminal block, take care not to subject the cable to stress.
After wiring, wire offcuts must not be left in the inverter. They may cause a fault, failure or malfunction.
A7AX.book 9 ページ 2005年9月22日 木曜日 午後7時40分
3
CONNECTION DIAGRAM AND TERMINAL
3.1 Connection Diagram
Relay contact signal input (sink logic
*3
) Open collector signal input (sink logic
*3
)
Thousand's place
Hundred's place
Ten's place
Unit's place
X15
X14
X13
X12
X11
X10
X9
X8
X7
X6
X5
X4
X3
X2
X1
X0
DY
SD
*1
FR-A7AX
AY41 type transistor output unit
*2
Thousand's place
Hundred's place
Ten's place
Unit's place
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
35
36
X7
X6
X5
X4
X3
X2
X1
X0
X15
X14
X13
X12
X11
X10
X9
X8
FR-A7AX
Inverter
Reading command
*2
DY
PC
*1
Inverter
*1 Use terminals SD or PC on the inverter.
*2 AY41 type unit requires 24VDC power.
Example of connection with the output module (AY41 type) of Mitsubishi PLC. Refer to the output module manual for details of the output module.
*3 The control logic is the same as that of the inverter.
When the logic of the inverter is changed, the option logic also changes. For details of changing the control logic, refer to the inverter manual.
9
3
A7AX.book 10 ページ 2005年9月22日 木曜日 午後7時40分
CONNECTION DIAGRAM AND TERMINAL
REMARKS
1.
As the input signals are at low level, use two parallel micro signal contacts or a twin contact for relay contact inputs to prevent a contact fault.
Micro signal contacts Twin contacts
2.
A transistor of the following specifications should be selected for the open collector signal:
Electrical characteristics of the transistor used
⋅ I c
≥ 10mA
⋅ Leakage current: 100
µ
A maximum
⋅ V
CE
≥ 30V
⋅ If I c
≥ 10mA, V
CE (sat) voltage is 3V maximum
10
A7AX.book 11 ページ 2005年9月22日 木曜日 午後7時40分
3.2 Internal Block Diagram
The following is the internal block diagram of the FR-A7AX.
CONNECTION DIAGRAM AND TERMINAL
Connector Controller
X0
X15
DY
11
3
A7AX.book 12 ページ 2005年9月22日 木曜日 午後7時40分
CONNECTION DIAGRAM AND TERMINAL
3.3 Terminals
X10
X11
X12
X13
X14
X15
DY
X4
X5
X6
X7
X8
X9
X0
X1
X2
X3
Terminal
Location
Terminal
Symbol
Plug-in option
Inverter
Description
X0 to X15
DY
SD
PC
Digital signal input terminal (frequency setting signal terminal)
Input the digital signal at the relay contact or open collector
For the digital signal input, you can choose either the BCD code input or binary input.
BCD code input ..3 digits (999 maximum) or 4 digits (9999 maximum)
Binary input ........binary 12 bits (X0 to X11, FFF
H
maximum) or binary 16 bits (X0 to X15, FFFF
H
maximum)
Data read timing input signal
Used when a digital signal read timing signal is necessary.
Data is read only during the DY signal is on.
By switching the DY signal off, the X0 to X15 data before signal-
off is retained. (Refer to page 18.)
Common terminal (sink)
Common terminal for digital and data read timing signals.
Use terminal SD of the inverter.
External transistor common terminal (sink), common terminal (source)
When connecting the transistor output (open collector output) of a programmable controller (PLC), etc., connect the external power common (+) to this terminal to prevent a fault occurring due to leakage current. When you have selected the source logic, this terminal is used as a common terminal. Use terminal
PC of the inverter.
12
A7AX.book 13 ページ 2005年9月22日 木曜日 午後7時40分
CONNECTION DIAGRAM AND TERMINAL
3.4 Code Input Example
The following explains examples of terminal status and input value at BCD code input and binary input.
Example: when the input value is 6325
BCD Code Input
Digit
1
10
100
1000
Terminal name
X8
X9
X10
X11
X12
X13
X14
X15
X4
X5
X6
X7
X0
X1
X2
X3
Terminal input status
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
Input value
5
2
3
6
Example: when the input value is AB65
H
Binary Input
Terminal name
Terminal input status
Input value
(hexadecimal)
Input value
(decimal)
X8
X9
X10
X11
X12
X13
X14
X15
X4
X5
X6
X7
X0
X1
X2
X3
ON
ON
OFF
ON
OFF
ON
OFF
ON
ON
OFF
ON
OFF
OFF
ON
ON
OFF
5
6
B
A
43877
CAUTION
For the BCD code input, the input value of each digit is from 0 to 9. When the value greater than 9 is input, it is made invalid and the last value is retained.
13
3
A7AX.book 14 ページ 2005年9月22日 木曜日 午後7時40分
4
PARAMETERS
4.1 Parameter List
When the FR-A7AX is fitted, the following parameters can be set.
The FR-A7AX does not function with the factory setting. When a value other than
"
9999
"
is set in Pr. 304, digital input is enabled.
Set the following parameters according to applications.
Parameter
Number
300
301
302
303
304
305
329
447
*4
448
*4
804
*4
Name
BCD code input bias
BCD code input gain
Binary input bias
Binary input gain
Selection of digital input and analog input compensation enable/disable
Data read timing signal on-off selection
Digital input increments selection
*3
Digital torque command bias
Digital torque command gain
Torque command source selection
Setting Range
0 to 400Hz
0 to 400Hz, 9999
0 to 400Hz
0 to 400Hz, 9999
0 to 4, 10 to 14,
9999
*1
0, 1, 10
0, 1, 2, 3
0 to 400%
0 to 400%, 9999
0, 1, 3 to 6
Initial
Value
0Hz
60Hz
(50Hz)
*2
0Hz
60Hz
(50Hz)
*2
Setting
Increments
0.01Hz
0.01Hz
0.01Hz
0.01Hz
Refer to page
9999
0
1
0
150%
0
1
1
1
1%
1%
1
14
A7AX.book 15 ページ 2005年9月22日 木曜日 午後7時40分
PARAMETERS
*1 Setting values "4" and "14" are available with the FR-A700 series only.
*2 The initial value of the EC version is 50Hz.
*3 For Pr. 329, write is disabled during operation even when "2" is set in Pr. 77. When changing the parameter setting, stop the operation. Also parameter clear is made invalid.
*4 These parameters can be set for the FR-A700 series only.
REMARKS
Binary input ............ The input data is taken in hexadecimal
BCD code input...... The input data is taken in decimal
15
4
A7AX.book 16 ページ 2005年9月22日 木曜日 午後7時40分
PARAMETERS
4.2 Parameter Setting
4.2.1
Selection of input method (Pr. 304)
Parameter
Number
304
Name
Selection of digital input and analog input compensation enable/disable
Setting Range
0 to 4,10 to 14,
9999
Pr. 304 Setting
2
3
0
1
4
*2
10
11
12
13
14
*2
9999
(initial value)
Binary Input
12bit
12bit
12bit
Torque command value input
16bit
16bit
16bit
Torque command value input
BCD Code Input
3 digits
3 digits
4 digits
4 digits
No function
Initial
Value
9999
Setting
Increments
1
Availability of Analog
Input Compensation
*1
(
{: enabled, ×: disabled)
×
×
{
{
×
×
{
{
16
A7AX.book 17 ページ 2005年9月22日 木曜日 午後7時40分
PARAMETERS
*1 Use terminal 1 for analog input compensation. Refer to the inverter instruction manual (applied) for details of terminal 1.
*2 These parameters can be set for the FR-A700 series only.
Refer to page 23 for details of torque command value input.
REMARKS
⋅ Signal X12 to X15 become invalid when 0 to 3 are set in Pr. 304.
⋅ Refer to page 13 for BCD code/ binary input example.
17
4
A7AX.book 18 ページ 2005年9月22日 木曜日 午後7時40分
PARAMETERS
4.2.2
Data read timing signal on-off selection (Pr. 305)
Parameter
Number
305
Name
Data read timing signal on-off selection
Setting Range
0, 1, 10
Initial
Value
0
Setting
Increments
1
Pr. 305 Setting
0
(initial value)
1
10
Filter
Without
Without
With
Description
The set frequency data entered from the digital signal input terminals (X0 to X15) is always imported independently of whether the DY signal is on or off.
The set frequency data entered from the digital signal input terminals (X0 to X15) is imported only when the DY signal is on.
The set frequency data is not imported when the DY signal is off.
Therefore, even if the input status of the X0-X15 signal changes, the set frequency data before off of the DY signal is valid.
The set frequency data entered from the digital signal input terminals (X0 to X15) is always imported independently of whether the DY signal is on or off.
The time lag when digital signals change can be compensated with a filter.
When "0 or 10" is set in Pr. 305
Filter (Pr. 305 = "10")
Digital signal input
(terminal X0 to X15)
20ms or more necessary*
Reflected on the set frequency
Set frequency
20ms maximum
* Hold the digital signal input (X0 to
X15) status for 20ms or more.
18
A7AX.book 19 ページ 2005年9月22日 木曜日 午後7時40分
PARAMETERS
z How to use the DY signal (when "1" is set in Pr. 305)
1ms or more
1ms or more
Digital signal input
(terminal X0 to X15)
20ms or more necessary
Data read timing signal
(terminal DY)
OFF ON
REMARKS
When Pr. 305 = "1", each terminal from X0 to X15 is all recognized as off when the inverter is turned on in terminal DY off status.
For example, when bias is set to 20Hz, turning the power supply on in the DY signal off status and then turning on the start signal will make the frequency command valid, starting the inverter to operate at 20Hz. z SERIAL number check
The setting of "10" for Pr. 305 can be used for the FR-A700 series and FR-F700 series 55K (01160 (EC
Version)) or less produced in June 2004 or later. Check the SERIAL number indicated on the inverter rating plate or package.
[SERIAL]
{
4 6
{{{{{{
Symbol Year Month Control number
19
4
A7AX.book 20 ページ 2005年9月22日 木曜日 午後7時40分
PARAMETERS
4.2.3
Bias and gain adjustment (Pr. 300, Pr. 301, Pr. 302, Pr. 303)
Parameter
Number
300
301
302
303
Name
BCD code input bias
BCD code input gain
Binary input bias
Binary input gain
Setting Range
0 to 400Hz
0 to 400Hz, 9999
0 to 400Hz
0 to 400Hz, 9999
Initial
Value
0Hz
60Hz
(50Hz)
*
0Hz
60Hz
(50Hz)
*
Setting
Increments
0.01Hz
0.01Hz
0.01Hz
0.01Hz
* The initial value of the EC version is 50Hz.
(1) Bias adjustment
Bias adjustments can be made for the digital input signal.
Set the set frequency at the digital input of 0.
⋅ BCD code input......Set using Pr. 300.
⋅ Binary input............Set using Pr. 302.
20
A7AX.book 21 ページ 2005年9月22日 木曜日 午後7時40分
PARAMETERS
(2) Gain adjustment
The gain may be set in either of the following two ways:
How to set the output frequency when the input signal is 999 or 9999 (BCD code), and FFF
H
or
FFFF
H
(binary).
⋅ BCD code input .. Set using Pr. 301.
⋅ Binary input ........ Set using Pr. 303.
The output frequency is factory-set to 60Hz (EC version : 50Hz).
Pr.301
Pr.303
Pr.300
Pr.302
0
0
Bias
Digital input signal
Gain
999(9999)
FFF
H
(FFFF
H
)
BCD
Pr.304=0,2
Binary (BIN) Pr.304=1,3
CAUTION
The maximum output frequency for operation with the digital input signal is the "gain" value set in
Pr. 301 and Pr. 303.
To set the maximum output frequency at 60Hz (EC version :
50Hz) or more, change
" gain
"
with the operation panel.
How to set the BCD code or binary value as the output frequency setting
When "9999" is set in Pr. 301 (BCD code) or Pr. 303 (binary), the digital input value is set as the output frequency.
(For example, to set the output frequency to 120Hz when the BCD code input is
"
120
"
)
120
0 120
Digital input signal
(BCD)
REMARKS
When this setting method is used, "bias" setting (Pr. 300 or
Pr. 302) cannot be made.
21
4
A7AX.book 22 ページ 2005年9月22日 木曜日 午後7時40分
PARAMETERS
4.2.4
Digital input increments selection (Pr. 329)
Parameter
Number
329
Name
Digital input increments selection
*1
Setting Range
0, 1, 2, 3
Initial
Value
1
Setting
Increments
1
When "9999" is set in Pr. 301 BCD code input gain or Pr. 303 Binary input gain, the increments when the digital signal is set as output frequency can be set.
Frequency = digital input signal value
× Pr. 329 input increments
Available Frequencies
*1
Pr. 329 Setting
Input Value
Increments
12bit
BCD code
0
1 (factory setting)
10
1
0 to 9990Hz
0 to 999Hz
2 0.1
0 to 99.9Hz
3 0.01
0 to 9.99Hz
*1 These are not the inverter maximum output frequencies.
Binary
0 to 40950Hz
0 to 4095Hz
0 to 409.5Hz
0 to 40.95Hz
BCD code
0 to 99990Hz
0 to 9999Hz
0 to 999.9Hz
0 to 99.99Hz
16bit
Binary
0 to 655350Hz
0 to 65535Hz
0 to 6553.5Hz
0 to 655.35Hz
REMARKS
When the values other than "9999" are set in Pr. 301 or Pr. 303, Pr. 329 is made invalid.
<Example>
Pr. 329 = 0 BCD code = 111
Binary = 100
H
(256 in decimal)
Pr. 329 = 1 BCD code = 111
Binary = 100
H
(256 in decimal)
Pr. 329 = 2 BCD code = 111
Binary = 100
H
(256 in decimal)
Pr. 329 = 3
BCD code = 111
Binary = 100
H
(256 in decimal)
→
→
→
→
→
→
→
→
1110Hz
2560Hz
111Hz
256Hz
11.1Hz
25.6Hz
1.11Hz
2.56Hz
22
A7AX.book 23 ページ 2005年9月22日 木曜日 午後7時40分
PARAMETERS
4.2.5
16 bit digital torque command (FR-A700 series only)
Parameter
304
447
448
804
Name
Selection of digital input and analog input compensation enable/disable
Digital torque command bias
Digital torque command gain
Torque command source selection
Setting Range
0 to 4, 10 to 14, 9999
0 to 400%
0 to 400%, 9999
0, 1, 3 to 6
Initial Value Increments
9999
0
150%
0
1
1%
1%
1
Digital torque command can be given under torque control using the FR-A7AX .
A digital command using the FR-A7AX can be given when "4 (12 bit)" or "14 (16 bit)" is set in Pr.304 and "4" is set in Pr.804 Torque command source selection.
Pr.804
parameter setting
0
1
Description
Torque command by terminal 1 analog input
Torque command by parameter setting
Setting value of Pr.805 or Pr.806 (-400% to 400%)
Remarks
Refer to the inverter manual for details.
3
4
5
6
Torque command by CC-Link communication (FR-A7NC)
12 bit digital input (FR-A7AX)
16 bit digital input (FR-A7AX)
Refer to the inverter manual for details.
Torque command by CC-Link communication (FR-A7NC)
Refer to the instruction manual of the
FR-A7NC for details.
When "4" is set in Pr. 304
When "14" is set in Pr. 304
Refer to the instruction manual of the
FR-A7NC for details.
23
4
A7AX.book 24 ページ 2005年9月22日 木曜日 午後7時40分
PARAMETERS
The input signal uses the last 15 (11) bits as torque command and the most significant bit as sign.
When 16 bit is selected
Bit15 Bit0 sign bit
0: positive, 1: negative
0 to 7FFF
H
or 0 to 190
H
(400)
REMARKS
The digital torque command is input only by binary input.
24
A7AX.book 25 ページ 2005年9月22日 木曜日 午後7時40分
PARAMETERS
z Input method of torque command
Torque command may be input in either of the following two ways:
(1) Method to define the torque command value for the input command by setting the torque command value when the input signal is 0 and plus side torque command value when the input signal is 7FFF
H
(7FF
H
) as shown in the graph
Set the torque command value when the input signal is "0" in Pr.447 and the torque command value when the input signal is "7FFF
H
(7FF
H
) in Pr.448 .
Torque command value
Pr.448
150%
Initial value
7FFF
H
(7FF
H
)
0
Pr.447
7FFF
H
(7FF
H
)
Digital input signal
Most significant bit = 1
-150%
Most significant bit = 0
25
4
A7AX.book 26 ページ 2005年9月22日 木曜日 午後7時40分
PARAMETERS
(2) Method to directly input the torque command value as numeral value in digital
When "9999" is set in Pr.448, the input signal is considered as a torque command value.
Even if a value higher than 190H (400) is input, the torque command value is clamped at 400%.
Torque command value
400%
7FFF
H
(7FF
H
)
190
H
(400)
Most significant bit = 1
0
190
H
(400)
-400%
Most significant bit = 0
7FFF
H
(7FF
H
)
Digital input signal
26
A7AX.book 27 ページ 2005年9月22日 木曜日 午後7時40分
PARAMETERS
4.3 Instructions
(1) Acceleration/deceleration time
When the frequency is set with the digital input signal, the acceleration/deceleration time is the period of time required to reach the Acceleration/deceleration reference frequency set in Pr. 20. This is the same as when using the analog signal input.
(2) There are the following restrictions on the digital input signal:
When the signal is used to enter a BCD code, 0A
H
to 0F
H
entries are ignored during operation and the previous inputs are used to continue operation.
If binary input is changed to BCD code input with 0A
H
to 0F
H
input, the set frequency becomes 0Hz.
(3) If 0 to 5V (0 to 10V) is input at the inverter terminal 1 from the external volume with the FR-A7AX fitted, the inverter operates at the frequency obtained by adding the FR-A7AX BCD code input and the compensation input from terminal 1 only when
"
2, 3, 12 or 13
"
is set in Pr. 304.
When switching the inputs e.g. between volume input to perform manual operation and BCD code input to perform automatic operation, set the BCD code input to "0" under manual operation.
(4) The priorities of the frequency setting are as follows.
JOG>Multi-speed operation (RH, RM, RL) >PID (X14) >AU (terminal 4) >Digital command by the FR-
A7AX > terminal 2
"
(When digital input is valid, terminal 2 is invalid.)
27
4
A7AX.book 28 ページ 2005年9月22日 木曜日 午後7時40分
REVISIONS
Print Date *Manual Number
May, 2004 IB(NA)-0600164ENG-A
Sep.,2005 IB(NA)-0600164ENG-B
*The manual number is given on the bottom left of the back cover.
Revision
First edition
Additions
Compatible with the FR-A700 series
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 5 Unpacking and Product Confirmation
- 5 Packing confirmation
- 6 Parts
- 7 Specifications
- 8 Pre-Installation Instructions
- 9 Installation Procedure
- 11 Wiring
- 13 Connection Diagram
- 15 Internal Block Diagram
- 16 Terminals
- 17 Code Input Example
- 18 Parameter List
- 20 Parameter Setting
- 20 Selection of input method (Pr. 304)
- 22 Data read timing signal on-off selection (Pr. 305)
- 24 Bias and gain adjustment (Pr. 300, Pr. 301, Pr. 302, Pr. 303)
- 26 Digital input increments selection (Pr. 329)
- 27 16 bit digital torque command (FR-A700 series only)
- 31 Instructions