A7AX.book 13 ページ 2005年9月22日 木曜日 午後7時40分
CONNECTION DIAGRAM AND TERMINAL
3.4 Code Input Example
The following explains examples of terminal status and input value at BCD code input and binary input.
Example: when the input value is 6325
BCD Code Input
Digit
1
10
100
1000
Terminal name
X8
X9
X10
X11
X12
X13
X14
X15
X4
X5
X6
X7
X0
X1
X2
X3
Terminal input status
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
Input value
5
2
3
6
Example: when the input value is AB65
H
Binary Input
Terminal name
Terminal input status
Input value
(hexadecimal)
Input value
(decimal)
X8
X9
X10
X11
X12
X13
X14
X15
X4
X5
X6
X7
X0
X1
X2
X3
ON
ON
OFF
ON
OFF
ON
OFF
ON
ON
OFF
ON
OFF
OFF
ON
ON
OFF
5
6
B
A
43877
CAUTION
For the BCD code input, the input value of each digit is from 0 to 9. When the value greater than 9 is input, it is made invalid and the last value is retained.
13
3
advertisement
Related manuals
advertisement
Table of contents
- 5 Unpacking and Product Confirmation
- 5 Packing confirmation
- 6 Parts
- 7 Specifications
- 8 Pre-Installation Instructions
- 9 Installation Procedure
- 11 Wiring
- 13 Connection Diagram
- 15 Internal Block Diagram
- 16 Terminals
- 17 Code Input Example
- 18 Parameter List
- 20 Parameter Setting
- 20 Selection of input method (Pr. 304)
- 22 Data read timing signal on-off selection (Pr. 305)
- 24 Bias and gain adjustment (Pr. 300, Pr. 301, Pr. 302, Pr. 303)
- 26 Digital input increments selection (Pr. 329)
- 27 16 bit digital torque command (FR-A700 series only)
- 31 Instructions