GoodWe SBP G2 Series User Manual
Below you will find brief information for ES 3.0-6.0kW G2, LX A5.0-10, LX A5.0-30, LX U5.4-L, LX U5.4-20, LX U5.0-30. These are components of a residential smart inverter solution. This manual covers product information, installation, electrical connection, commissioning, troubleshooting, and maintenance. The energy storage system converts solar energy into electricity, and smart devices manage power consumption intelligently.
Advertisement
Advertisement
Residential Smart Inverter Solutions ES 3.0-6.0kW G2 LX A5.0-10 LX A5.0-30 LX U5.4-L LX U5.4-20 LX U5.0-30 User Manual V1.1-2025-04-14 1 Copyright Statement Copyright©GoodWe Technologies Co.,Ltd. 2024. All rights reserved. No part of this manual can be reproduced or transmitted to the public platform in any form or by any means without the prior written authorization of GoodWe. Trademarks and other GoodWe trademarks are trademarks of GoodWe Company. All other trademarks or registered trademarks mentioned in this manual are owned by GoodWe Company. NOTICE The information in this user manual is subject to change due to product updates or other reasons. This guide cannot replace the product labels or the safety precautions in the user manual unless otherwise specified. All descriptions in the manual are for guidance only. 2 CONTENT 1 About This Manual ........................................................................................................................................................8 1.1 Overview ................................................................................................................................................................8 1.2 Applicable Model ..............................................................................................................................................8 1.3 Symbol Definition ............................................................................................................................................. 9 2 Safety Precaution ........................................................................................................................................................... 9 2.1 General Safety .................................................................................................................................................. 10 2.2 Personnel Requirements .............................................................................................................................10 2.3 System Safety ................................................................................................................................................... 10 2.3.1 PV String Safety ..................................................................................................................................12 2.3.2 Inverter Safety ..................................................................................................................................... 12 2.3.3 Battery Safety ...................................................................................................................................... 12 2.3.4 Smart Meter Safety ...........................................................................................................................14 2.4 Safety Symbols and Certification Marks ............................................................................................ 14 2.5 EU Declaration of Conformity ..................................................................................................................16 2.5.1 Equipment with Wireless Communication Modules ...................................................... 16 2.5.2 Equipment without Wireless Communication Modules (Except Battery) ...........16 2.5.3 Battery ..................................................................................................................................................... 17 3 System Introduction ...................................................................................................................................................18 3.1 System Overview ............................................................................................................................................ 18 3.2 Product Overview ...........................................................................................................................................22 3.2.1 Inverter ....................................................................................................................................................22 3.2.2 Battery ..................................................................................................................................................... 23 3.2.3 Smart Meter ......................................................................................................................................... 25 3.2.4 Smart Dongle .......................................................................................................................................25 3.3 Supported Grid Types .................................................................................................................................. 26 3 3.4 System Working Mode ................................................................................................................................ 26 4 Check and Storage ......................................................................................................................................................32 4.1 Check before Acceptance.......................................................................................................................... 32 4.2 Deliverables ....................................................................................................................................................... 33 4.2.1 Inverter Deliverables (ES G2) .......................................................................................................33 4.2.2 Battery Deliverables (LX A5.0-10) ............................................................................................. 34 4.2.3 Battery Deliverables (LX A5.0-30) ............................................................................................. 35 4.2.4 Battery Deliverables (LX U5.0-30) .............................................................................................36 4.2.5 Battery Deliverables (LX U5.4-L, LX U5.4-20) ......................................................................37 4.2.6 Busbar (optional) ............................................................................................................................... 37 4.2.7 Smart Meter Deliverables ............................................................................................................. 38 4.2.8 Smart Dongle .......................................................................................................................................40 4.3 Storage ................................................................................................................................................................. 41 5 Installation .......................................................................................................................................................................42 5.1 System Installation and Commissioning Procedure.................................................................... 43 5.2 Installation Requirements .......................................................................................................................... 43 5.2.1 Installation Environment Requirements ................................................................................ 43 5.2.2 Installation Space Requirements ...............................................................................................45 5.2.3 Tool Requirements ............................................................................................................................ 46 5.3 Equipment Handling .....................................................................................................................................48 5.4 Installing the Inverter ................................................................................................................................... 48 5.5 Installing the Battery System ................................................................................................................... 49 5.6 Installing the Smart Meter .........................................................................................................................55 6 System Wirings ............................................................................................................................................................. 57 6.1 System Wiring Diagram .............................................................................................................................. 58 6.2 Detailed System Wiring Diagram...........................................................................................................59 4 6.2.1 Detailed System Wiring Diagram for Single Inverter System ....................................59 6.2.2 Detailed System Wiring Diagram for Parallel System ....................................................61 6.3 Preparing Materials ....................................................................................................................................... 62 6.3.1 Preparing Breakers ............................................................................................................................63 6.3.2 Preparing Cables ................................................................................................................................64 6.4 Connecting the PE cable .............................................................................................................................66 6.5 Connecting the PV Cable........................................................................................................................... 67 6.6 Connecting the Battery Cable................................................................................................................. 69 6.6.1 Connecting the Power Cable between the Inverter and Battery .............................84 6.6.2 Connecting the Communication Cable between the Inverter and Battery ....... 87 6.7 Connecting the AC Cable ...........................................................................................................................89 6.8 Connecting the Meter Cable........................................................................................................................... 90 6.9 Connecting the Inverter Communication Cable ............................................................................94 7 System Power On .........................................................................................................................................................99 7.1 Check before Power ON ............................................................................................................................. 99 7.2 Power ON ............................................................................................................................................................99 7.3 Indicators ..........................................................................................................................................................101 7.3.1 Inverter Indicators ...........................................................................................................................101 7.3.2 Battery Indicators ............................................................................................................................102 7.3.3 Smart Meter Indicator .................................................................................................................. 107 7.3.4 Smart Dongle Indicator ............................................................................................................... 108 8 Quick System Commissioning ............................................................................................................................. 112 8.1 Downloading the App .................................................................................................................................112 8.2 Connecting Inverter via SolarGo ..........................................................................................................113 8.3 Communication Settings...........................................................................................................................115 8.4 Quick Settings .................................................................................................................................................115 8.5 Creating Power Plants................................................................................................................................ 119 5 9 System Commissioning...........................................................................................................................................121 9.1 SolarGo Overview......................................................................................................................................... 121 9.1.1 Menu Structure of the App ......................................................................................................... 121 9.1.2 Login Page of SolarGo App ......................................................................................................... 122 9.1.3 Home Page of SolarGo App ........................................................................................................ 123 9.2 Connecting Inverter via SolarGo ..........................................................................................................124 9.3 Quick Settings .................................................................................................................................................126 9.4 Communication Settings ...........................................................................................................................129 9.5 Setting the Basic Information .................................................................................................................130 9.5.1 Setting Shadow Scan and SPD...................................................................................................130 9.5.2 Setting Advanced Parameters .................................................................................................. 131 9.5.3 Setting Power Limit Parameters...............................................................................................132 9.5.4 Setting the Battery Parameters................................................................................................ 132 9.5.5 Setting Generator Parameters ..................................................................................................136 9.5.6 Setting Load Control ..................................................................................................................... 137 9.6 Setting Safety Parameters ....................................................................................................................... 138 9.6.1 Setting the Basic Safety Parameters ..................................................................................... 138 9.6.2 Setting Customized Safety Parameters ................................................................................ 139 10 Monitoring Power Plant......................................................................................................................................144 10.1 SEMS Portal Overview ............................................................................................................................ 145 10.2 Manage Power Plant or Equipment ................................................................................................ 147 10.2.1 Creating the Power Plant ..........................................................................................................147 10.2.2 Managing the Power Plant ......................................................................................................148 10.2.3 Managing the Equipment in the Power Plant ...............................................................149 10.3 Power Plant Monitoring .........................................................................................................................150 10.3.1 Viewing Power Plant Information ........................................................................................150 10.3.2 Checking Alarms............................................................................................................................ 151 6 11 Maintenance............................................................................................................................................................. 153 11.1 Power OFF the System ............................................................................................................................153 11.2 Removing the Equipment ..................................................................................................................... 154 11.3 Disposing of the Equipment ................................................................................................................155 11.4 Routine Maintenance.............................................................................................................................. 155 11.5 Troubleshooting......................................................................................................................................... 156 11.5.1 System Troubleshooting ........................................................................................................... 157 11.5.2 Inverter Troubleshooting..........................................................................................................159 11.5.3 Battery Fault (LX A5.0-30, LX U5.0-30) ..............................................................................169 11.5.4 Battery Fault(LX A5.0-10)................................................................................................... 172 11.5.5 Battery Fault (LX U5.4-L) ...........................................................................................................174 11.5.6 Battery Fault (LX U5.4-20) ........................................................................................................176 12 Parameters ................................................................................................................................................................. 178 12.1 Inverter Parameters ..................................................................................................................................178 12.2 Battery Parameters ................................................................................................................................... 192 12.3 Smart Meter Technical Data................................................................................................................ 199 12.4 Smart Dongle Technical Data..............................................................................................................202 13 Appendix .....................................................................................................................................................................207 13.1 FAQ....................................................................................................................................................................207 13.1.1 How to Perform Meter/CT Detection?.................................................................................207 13.1.2 How to Upgrade the Device Version ................................................................................. 207 13.2 Abbreviations ...............................................................................................................................................207 13.3 Term Explanation ....................................................................................................................................... 210 7 1 About This Manual 1.1 Overview The energy storage system consists of inverter, battery system, and smart meter. This manual describes the product information, installation, electrical connection, commissioning, troubleshooting and maintenance of the system. Read through this manual before installing and operating the product. All the installers and users have to be familiar with the product features, functions, and safety precautions. This manual is subject to update without notice. For more product details and latest documents, visit https://en.goodwe.com/. 1.2 Applicable Model The energy storage system consists of the following products: Product Product type information Inverter ES Series LX A5.0-10 LX A5.0-30 Battery system Description Nominal output power: 3.0kW- 6.0kW Usable energy of 5.0kWh, supports a maximum of 15 batteries connected in parallel. Usable energy of 5.12kWh, supports a maximum of 30 batteries connected in parallel. LX U5.4-L Usable energy of 5.4kWh, supports a maximum of 6 LX U5.4-20 batteries connected in parallel. LX U5.0-30 Usable energy of 5.12kWh, supports a maximum of 30 batteries connected in parallel. GM1000 Smart Meter GMK110 It is a monitoring module in the energy storage system GM3000 which can detect information such as operating voltage, GM1000D current, and other data in the system. GMK110D Smart dongle LS4G Kit-CN 4G Kit-CN Only applicable to China and in a single inverter system. 8 4G Kit-CN-G20 4G Kit-CN-G21 Wi-Fi Kit WiFi/LAN Kit-20 In the single inverter scenario, system operation information can be uploaded to a monitoring platform through WiFi or LAN signals. In parallel system with multi inverters, it is installed on Ezlink3000 the master inverter to upload the system running information to monitoring platform through WiFi or LAN signals. 1.3 Symbol Definition DANGER Indicates a high-level hazard that, if not avoided, will result in death or serious injury. WARNING Indicates a medium-level hazard that, if not avoided, could result in death or serious injury. CAUTION Indicates a low-level hazard that, if not avoided, could result in minor or moderate injury. NOTICE Highlight and supplement the texts. Or some skills and methods to solve product-related problems to save time. 2 Safety Precaution Please strictly follow these safety instructions in the user manual during the operation. WARNING The inverters are designed and tested strictly complies with related safety rules. Read and follow all the safety instructions and cautions before any operations. Improper operation might cause personal injury or property damage as the inverters are electrical equipment. 9 2.1 General Safety NOTICE The information in this user manual is subject to change due to product updates or other reasons. This guide cannot replace the product labels or the safety precautions in the user manual unless otherwise specified. All descriptions in the manual are for guidance only. Before installations, read through the user manual to learn about the product and the precautions. All installations should be performed by trained and knowledgeable technicians who are familiar with local standards and safety regulations. Use insulating tools and wear personal protective equipment (PPE) when operating the equipment to ensure personal safety. Wear anti-static gloves, clothes, and wrist strip when touching electronic components to protect the inverter from damage. Unauthorized dismantling or modification may damage the equipment, and the damage is not covered under the warranty. Strictly follow the installation, operation, and configuration instructions in this manual. The manufacturer shall not be liable for equipment damage or personal injury if you do not follow the instructions. For more warranty details, please visit: https://en.goodwe.com/warranty 2.2 Personnel Requirements NOTICE Personnel who install or maintain the equipment must be strictly trained, learn about safety precautions and correct operations. Only qualified professionals or trained personnel are allowed to install, operate, maintain, and replace the equipment or parts. 2.3 System Safety DANGER Disconnect the upstream switches to power off the equipment before any electrical connections. Do not work with power on. Otherwise, an electric shock may occur. Install a breaker at the voltage input side of the equipment to prevent personal injury or equipment damage caused by energized electrical work. All operations such as transportation, storage, installation, use and maintenance shall comply with applicable laws, regulations, standards and specifications. 10 Perform electrical connections in compliance with local laws, regulations, standards and specifications, including operations, cables, and component specifications. Connect cables with the connectors included in the package. The manufacturer shall not be liable for equipment damage if other connectors are used. Ensure all cables are connected tightly, securely, and correctly. Inappropriate wiring may cause poor contacts or high impedances, and damage the inverter. The PE cables must be connected and secured properly. To protect the equipment and components from damage during transportation, ensure that the transportation personnel are professionally trained. All operations during the transportation have to be recorded. The equipment shall be kept in balance, thus avoiding falling down. The equipment is heavy. Please equip the corresponding personnel according to its weight, so that the equipment does not exceed the weight range of the human body can carry, and cause personnel injury. Keep the equipment stable to avoid dumping, which can result in equipment damage and personal injuries. WARNING Do not apply mechanical load to terminals, otherwise the terminals may be damaged. If the cable bears too much tension, the connection may be poor. Reserve a certain length of the cable before connecting it to the inverter cable port. Tie the cables of the same type together, and place cables of different types at least 30mm apart. Do not place the cables entangled or crossed. Place the cables at least 30mm away from the heating components or heat sources, otherwise the insulation layer of the cables may be aging or broken due to high temperature. 11 2.3.1 PV String Safety WARNING Ensure the PV module frames and the bracket system are securely grounded. Ensure the DC cables are connected tightly, securely, and correctly. Inappropriate wiring may cause poor contacts or high impedances, and damage the inverter. Measure the DC cables with a multimeter to avoid reverse polarity connection. Also, the voltage should be under the permissible range. Measure the DC cable using the multimeter to avoid reverse polarity connection. Also, the voltage should be under the max DC input voltage. The manufacturer shall not be liable for the damage caused by reverse connection and overvoltage. The PV strings cannot be grounded. Ensure the minimum insulation resistance of the PV string to the ground meets the minimum insulation resistance requirements before connecting the PV string to the inverter (R=maximum input voltage (V)/ 30mA). Do not connect one PV string to more than one inverter at the same time. Otherwise, it may cause damage to the inverter. The PV modules used with inverters must comply with IEC 61730 Class A standard. 2.3.2 Inverter Safety WARNING PV system is not suitable to connect equipment that relies on a stable power supply, such as: medical equipment to sustain life. Ensure that no personal injury is occurred when the system is disconnected. The voltage and frequency at the connecting point should meet the on-grid requirements. Additional protective devices like circuit breakers or fuses are recommended on the AC side. Specification of the protective device should be at least 1.25 times the maximum AC output current. The arc fault alarms will be cleared automatically if the alarms are triggered less than 5 times in 24 hours. The inverter will shut down for protection after the 5th electric arc fault. The inverter can operate normally after the fault is solved. BACK-UP is not recommended if the PV system is not configured with batteries. Otherwise, the risk in system power usage is beyond the equipment manufacturer's warranty scope. 2.3.3 Battery Safety DANGER 12 Keep Power Off before any operations to avoid danger. Strictly follow all safety precautions outlined in this manual and safety labels on the equipment during the operation. Do not disassemble, modify, or replace any part of the battery or the power control unit without official authorization from the manufacturer. Otherwise, it will cause electrical shock or damages to the equipment, which shall not be borne by the manufacturer. Do not hit, pull, drag, squeeze or step on the equipment or put the battery into fire. Otherwise, the battery may explode. Do not place the battery in a high temperature environment. Make sure that there is no direct sunlight and no heat source near the battery. When the ambient temperature exceeds 60 ℃, it will cause fire. Do not use the battery or the power control unit if it is defective, broken, or damaged. Damaged battery may leak electrolyte. Do not move the battery system while it is working. Contact after-sales service if the battery shall be replaced or added. A short circuit in the battery may cause personal injury. The instantaneous high current caused by a short circuit can release a large amount of energy and may cause a fire. WARNING Factors such as: temperature, humidity, weather, etc. may limit the battery's current and affect its loading capacity. Contact after-sale service immediately if the battery is not able to be started. Otherwise, the battery might be damaged permanently. Inspect and maintain the battery regularly according to the maintenance requirements of the battery. Emergency Measures Battery Electrolyte Leakage If the battery module leaks electrolyte, avoid contact with the leaking liquid or gas because the electrolyte is corrosive, and will cause skin irritation or chemical burn to the operator. Anyone contact the leaked substance accidentally has to do as following: Breath in the leaked substance: Evacuate from the polluted area, and seek immediate medical assistance. Eye contact: Rinse your eyes for at least 15 minutes with clean water and seek immediate medical assistance. Skin contact: Thoroughly wash the touch area with soap and clean water, and seek immediate medical assistance. Ingestion: Induce vomiting, and seek immediate medical assistance. 13 Fire The battery may explode when the ambient temperature exceeds 150℃. Poisonous and hazardous gas may be released if the battery is on fire. In the event of a fire, please make sure that the carbon dioxide extinguisher or Novec1230 or FM-200 is nearby. The fire cannot be put out by ABC dry powder extinguisher. Firefighters are required to wear full protective clothing and self-contained breathing apparatus. Battery fire protection For batteries with fire protection functions, perform the following operations after the fire protection function is triggered: Immediately cut off the main power switch to ensure that no current passes through the battery system. Conduct a preliminary inspection of the appearance of the battery to determine if there is any damage, deformation, leakage, or odor. Check the battery casing, connectors, and cables. Use temperature sensors to detect the temperature of the battery and its environment, ensuring there is no risk of overheating. Isolate and label damaged batteries, and handle them properly in accordance with local regulations. 2.3.4 Smart Meter Safety WARNING If the voltage of the power grid fluctuates, resulting in the voltage to exceed 265V. In this case, long-term overvoltage operation may cause damage to the meter. It is recommended to add a fuse with a nominal current of 0.5A on the voltage input side of the meter to protect it. 2.4 Safety Symbols and Certification Marks DANGER All labels and warning marks should be visible after the installation. Do not cover, scrawl, or damage any label on the equipment. The following descriptions are for reference only. No. Symbol Referring to 14 1 2 3 Potential risks exist. Wear proper PPE before any operations. High Voltage Hazard. Disconnect all incoming power and turn off the product before working on it. High-temperature hazard. Do not touch the product under operation to avoid being burnt. 4 Operate the equipment properly to avoid explosion. 5 Batteries contain flammable materials, beware of fire. 6 7 The equipment contains corrosive electrolytes. In case of a leak in the equipment, avoid contact the leaked liquid or gas. Delay discharge. Wait 5 minutes after power off until the components are completely discharged. 8 Install the equipment away from fire sources. 9 Keep the equipment away from children. 10 Do not pour with water. 11 Read through the user manual before any operations. 12 Wear personal protective equipment during installation, operation and maintaining. 15 Do not dispose of the System as household waste. Deal with it 13 in compliance with local laws and regulations, or send it back to the manufacturer. 14 Grounding point. 15 Recycle regeneration mark. 16 CE mark. 17 TUV Mark. 18 RCM Mark. 2.5 EU Declaration of Conformity 2.5.1 Equipment with Wireless Communication Modules GoodWe Technologies Co., Ltd. hereby declares that the equipment with wireless communication modules sold in the European market meets the requirements of the following directives: Radio Equipment Directive 2014/53/EU (RED) Restrictions of Hazardous Substances Directive 2011/65/EU and (EU) 2015/863 (RoHS) Waste Electrical and Electronic Equipment 2012/19/EU Registration, Evaluation, Authorization and Restriction of Chemicals (EC) No 1907/2006 (REACH) 2.5.2 Equipment without Wireless Communication Modules (Except Battery) GoodWe Technologies Co., Ltd. hereby declares that the equipment without wireless communication modules sold in the European market meets the requirements of the following directives: Electromagnetic compatibility Directive 2014/30/EU (EMC) 16 Electrical Apparatus Low Voltage Directive 2014/35/EU (LVD) Restrictions of Hazardous Substances Directive 2011/65/EU and (EU) 2015/863 (RoHS) Waste Electrical and Electronic Equipment 2012/19/EU Registration, Evaluation, Authorization and Restriction of Chemicals (EC) No 1907/2006 (REACH) 2.5.3 Battery GoodWe Technologies Co., Ltd. hereby declares that batteries sold in the European market meets the requirements of the following directives: Electromagnetic compatibility Directive 2014/30/EU (EMC) Electrical Apparatus Low Voltage Directive 2014/35/EU (LVD) Battery Directive 2006/66/EC and Amending Directive 2013/56/EU Waste Electrical and Electronic Equipment 2012/19/EU Registration, Evaluation, Authorization and Restriction of Chemicals (EC) No 1907/2006 (REACH) You can download the EU Declaration of Conformity on the official website: https://en.goodwe.com。 17 3 System Introduction 3.1 System Overview The residential smart inverter solution consists of inverter, battery system, smart meter, smart dongle, etc.. In the PV system, solar energy can be converted to electric energy for household needs. The IoT devices in the system manage the electrical equipment and energy consumption in a smart way by recognizing the overall power consumption and deciding whether the power is to be used by the loads, stored in batteries, or exported to the grid, etc. WARNING Select the battery model according to the inverter model and the approved battery list. For battery requirements used in the same system, such as whether the models can be mixed and matched, and whether the capacities are consistent, refer to the corresponding model's battery user manual or contact the battery manufacturer for relevant requirements. Battery Compatibility Overview: https://en.goodwe.com/Ftp/EN/Downloads/User%20Manual/GW_Battery%20Compatibility%20 Overview-EN.pdf Due to product upgrades or other reasons, the document content may be updated irregularly. For the matching relationship between inverters and IoT products, refer to: https://en.goodwe.com/Ftp/EN/Downloads/User%20Manual/GW_Compatibility-list-of-GoodWe 18 -inverters-and-IoT-products-EN.pdf In the parallel system, it is not supported to connect third-party EMS monitoring devices. When the number of inverters connected in parallel in the system is ≤ 3, UPS function is supported; When the number of inverters connected in parallel in the system exceeds 3, UPS function is not supported. The complexity of the parallel system increases with the number of inverters. When the number of inverters in the system is ≥ 6, contact the after-sales service center to confirm the installation and application environment of the inverters to ensure stable operation of the system. When the value of power limit is set to 0W, the combined use of AC coupled inverters and grid-tied inverters is not supported. The combined use of AC coupled inverters and grid-tied inverters requires that the value of power limit of the system is greater than 5% of the nominal power of the grid-tied inverter. Product Type Model Description When multiple inverters are used in the system, it is not supported to be connected to a generator; it supports up to 16 inverters to form a parallel system. When the number of inverters connected in parallel in GW3000-ES-20 GW3600-ES-20 GW3600M-ES-20 GW5000-ES-20 Inverter the system is ≤ 3, UPS function is supported; When the number of inverters in the system exceeds 3, UPS function is not supported. The complexity of the parallel system increases with the number of inverters. When the number of inverters in GW5000M-ES-20 the system is ≥ 6, contact the after-sales service center GW6000-ES-20 to confirm the installation and application environment GW6000M-ES-20 of the inverters to ensure stable operation of the system. GW3600-SBP-20 GW5000-SBP-20 GW6000-SBP-20 GW3500L-ES-BR20 GW3600-ES-BR20 GW6000-ES-BR20 GW3600-SBP-20, GW5000-SBP-20, GW6000-SBP-20: cannot be used to form a parallel system. For GW3600M-ES-20, GW5000M-ES-20, GW6000M-ES-20, GW3600-SBP-20, GW5000-SBP-20, GW6000-SBP-20, lead-acid battery is not supported. Requirements for parallel system: The software version of all inverters in the system is the same. The ARM software version of the inverter is 08 (418) and above. The DSP software version of the inverter is 08 (8808) 19 and above. LX A5.0-10 Battery of different models cannot be mixed. LX A5.0-10: The nominal charging and discharging current of a single battery is 60A; a maximum of 15 LX A5.0-30 batteries can be connected in parallel in one system. LX A5.0-30: The nominal charging current of a single LX U5.4-L battery is 60A, and the nominal discharging current is 100A; the maximum charging current is 90A; the maximum discharging current is 150A. A maximum of 30 LX U5.4-20 batteries can be connected in parallel in one system. LX U5.4-L, LX U5.4-20: The nominal charging and discharging current of a single battery is 50A; a Battery maximum of 6 batteries can be connected in parallel in system one system. LX U5.0-30 LX U5.0-30: The nominal charging current of a single battery is 60A, and the discharging current is 100A; the maximum charging current is 90A; the maximum discharging current is 100A. A maximum of 30 batteries can be connected in parallel in one system. Supports connecting to lead-acid batteries of AGM, GEL, and Flooded types. Lead-acid Battery The number of batteries that can be connected in series is decided by the voltage of lead-acid batteries, and the total voltage of batteries connected in series is not allowed to exceed 60V. When the charging and discharging current between the battery and the inverter is less than 120A, it supports direct connection between battery and inverter without BCB-11-WW-0 BCB-22-WW-0 Busbar BCB-32-WW-0 using a busbar. For example: it supports connecting GW3000-ES-20 to LX A5.0-30 without using a busbar. For detailed battery wiring methods, refer to section 6.6 Connecting the Battery Cable. BCB-33-WW-0 When multiple inverters are used in the system, a busbar (Purchase from needs to be connected. If using batteries from other GoodWe) brands, consult the corresponding manufacturer for the method of connecting the battery to the busbar. When the charging and discharging current between battery and inverter is ≥120A, a busbar or busbar box must be used to connect the inverter. (Current ≥ M x IBat 20 nominal. (M: the quantity of batteries connected in parallel in the system, IBat nominal: the nominal current of the battery). BCB-11-WW-0: used with LX A5.0-10, the battery system supports a maximum working current of 360A, working power of 18kW, and can be connect to a maximum of 3 inverter, and 6 batteries. BCB-22-WW-0: used with LX A5.0-10, the battery system supports a maximum working current of 720A, working power of 36kW, and can be connected to a maximum of 6 inverter, and 12 batteries. used with LX A5.0-30, the battery system supports a maximum working current of 720A, working power of 36kW, and can be connected to a maximum of 6 inverter, and 6 batteries. BCB-32-WW-0: used with LX A5.0-10, the battery system supports a maximum working current of 720A, working power of 36kW, and can be connected to a maximum of 6 inverters and 15 batteries. used with LX A5.0-30, the battery system supports a maximum working current of 720A, working power of 36kW, and can be connected to a maximum of 6 inverters and 15 batteries. used with LX U5.0-30, the battery system supports a maximum working current of 720A, working power of 36kW, and can be connected to a maximum of 6 inverter, and 8 batteries. BCB-33-WW-0: used with LX U5.0-30, the battery system supports a maximum working current of 720A, working power of 36kW, and can be connected to a maximum of 6 inverters, and 15 batteries. When the number of batteries exceeds 8, two 600A fuses need to be connected in parallel. Others: prepare the busbar based on actual system power and current. 21 It is not supported to replace the original CT, CT ratio: 120A/40mA. In the parallel system, the smart meter needs GMK110 GMK110D Smart Meter to be connected to the master inverter. GMK110, GM1000: CT x 1; GMK110 or GM1000 smart meter is standard. GM1000 GM1000D, GMK110D: CT x 2; used for AC coupled GM1000D inverters and need to be purchased separately. GM3000 GM3000: CT x 3; when a three-phase load is used in the system and output power needs to be controlled, a GM3000 meter is required and needs to be purchased separately. LS4G Kit-CN, 4G Kit-CN, 4G Kit-CN-G20 or 4G Kit-CN-G21 is only applicable to China and used in single inverter system. Smart dongle When using Wi-Fi Kit or WiFi/LAN Kit-20 smart dongle in LS4G Kit-CN 4G Kit-CN 4G Kit-CN-G20 network security version, the firmware version should be 4G Kit-CN-G21 01 or later. Wi-Fi Kit WiFi/LAN Kit-20 (Standard) Ezlink3000 (Purchase from GoodWe) a single inverter system, the firmware version should be 04 or later; If the WiFi/LAN Kit-20 smart dongle is a In a parallel system, only master inverter needs to be connected to Ezlink3000, and slave inverter does not need to be connected to smart dongle. Ezlink3000 firmware version is 04 or later. Only one Ezlink3000 and one smart meter need to be installed in the same system. The inverter connected with the Ezlink module and the meter defaults to be the master inverter, while the other inverters are the slave inverters. The master inverter issues commands to the slave inverters via the communication cables. 3.2 Product Overview 3.2.1 Inverter Inverters control and optimize the power in PV systems through an integrated energy management system. The power generated in the PV system can be used, stored in the battery, and output to the utility grid, and etc. 22 Nominal output No. Model 1 GW3000-ES-20 3kW 220/230/240V 2 GW3600-ES-20 3.68kW 220/230/240V 3 GW3600M-ES-20 3.68kW 220/230/240V 4 GW5000-ES-20 5kW*1 220/230/240V 5 GW5000M-ES-20 5kW*1 220/230/240V 6 GW6000-ES-20 6kW*1 220/230/240V 7 GW6000M-ES-20 6kW*1 220/230/240V 8 GW6000-ES-BR20 6kW 220V 9 GW3500L-ES-BR20 3.5kW 127V 10 GW3600-ES-BR20 3.68kW 220V 11 GW3600-SBP-20 3.68kW 220/230/240V 12 GW5000-SBP-20 5kW 220/230/240V 13 GW6000-SBP-20 6kW 220/230/240V power Nominal output voltage *1: 4600 for VDE-AR-N4105 & NRS 097-2-1. 3.2.2 Battery The battery system can store and discharge electricity according to the requirements of the PV energy storage system. The input and output ports of the energy storage system are both high-voltage direct current. ES G2 inverters support using with lead-acid batteries. Obtain product information related to 23 lead-acid batteries from the lead-acid battery manufacturer. LX A5.0-10 LX A5.0-30 LX U5.4-L, LX U5.4-20 LX U5.0-30 24 3.2.3 Smart Meter The smart meter can measure and monitor the data in the photovoltaic energy storage system, such as voltage, current, frequency, power factor, and power. No. Model Applicable scenarios It is not supported to replace the original CT, CT ratio: 120A/40mA. GM1000 GMK110 1 GM3000 GM1000D GM110D GMK110, GM1000: CT x 1; GMK110 or GM1000 smart meter is standard. GM1000D, GM110D: CT x 2; used for AC coupled inverters; and need to be purchased separately. GM3000: CT x 3; when a three-phase load is used in the system and output power needs to be controlled, a GM3000 meter is required and need to be purchased separately. 3.2.4 Smart Dongle The smart dongle can transmit various power generation data to SEMS Portal, the remote monitoring platform in real time, and can communicate with the SolarGo App to complete the near-end equipment commissioning. 25 No. 1 2 Model LS4G Kit-CN 4G Kit-CN 4G Kit-CN-G20 Signal Applicable scenarios 4G 4G, bluetooth 4G Kit-CN-G21 4G, bluetooth, CNSS 3 Wi-Fi Kit WiFi 4 WiFi/LAN Kit-20 Bluetooth, WiFi, LAN 5 Ezlink3000 Bluetooth, WiFi, LAN Single inverter scenario Master inverter of a parallel system 3.3 Supported Grid Types 3.4 System Working Mode Self-Use Mode Self-use mode is the basic working mode of the system. 26 The power generated by the PV system supplies the loads in priority, and the excess power will charge the batteries, then the remaining power will be sold to the utility grid. When the power generated in the PV system is insufficient, the battery will supply the loads in priority. If the battery power is insufficient, the load will be powered by the utility grid. Back-up Mode The BACK-UP mode is mainly applied to the scenario where the grid is unstable. When the grid is disconnected, the inverter turns to off-grid mode and the battery will supply power to the BACK-UP loads; when the grid is restored, the inverter switches to grid-tied mode. To ensure that the battery SOC is sufficient to maintain normal operation of the system when it is off grid, the battery will be charged to the backup power SOC using PV or grid power during grid connected operation. If you need to purchase electricity from the grid to charge the battery, please confirm the compliance with local power grid laws and regulations. 27 TOU Mode 28 Set different time periods for buying and selling electricity based on the difference in peak and valley electricity prices of the grid under the premise of complying with local laws and regulations. For example, set the battery to the charge mode during Valley period, and set the battery to discharge mode during Peak period to power the load with the battery. 29 Smart Charging Mode In some countries/regions, the PV power fed into the utility grid is limited. Set peak limit power, charge the battery using the surplus power when the PV power exceeds the peak limit power, or set charging time during which the PV power can be used to charge the battery. 30 31 Peakshaving Mode Peakshaving mode is mainly applicable to industrial and commercial scenarios. When the total power consumption of the loads exceeds the peak shaving limit in short time, the battery discharges to reduce the power consumption exceeding the peak shaving limit. If the SOCs of the two connected battery systems are lower than the reserved SOC for peakshaving, the system will buy power from the utility grid according to the set time period, load consumption, and the Import Power Limit. If the SOC of one battery system is lower than the reserved SOC for peakshaving, the system will buy power from the utility grid according to the load consumption and the Import Power Limit. 4 Check and Storage 4.1 Check before Acceptance Check the following items before receiving the product. 32 1. Check the outer packing box for damage, such as holes, cracks, deformation, and others signs of equipment damage. Do not unpack the package and contact the supplier as soon as possible if any damage is found. 2. Check the inverter model. If the inverter model is not what you requested, do not unpack the product and contact the supplier. 4.2 Deliverables WARNING Check the deliverables for correct model, complete contents, and intact appearance. Contact the supplier as soon as possible if any damage is found. 4.2.1 Inverter Deliverables (ES G2) Parts Description Parts Description Inverter x 1 Mounting plate x 1 Expansion screws x 3 Screw x N Battery power PE terminal x 1 terminal x 2 PV DC terminal SBP series inverter x 0 Smart dongle x 1 GW3000-ES-20: x 1 Others: x 2 2PIN terminal x 3 3PIN terminal x 1 6PIN terminal x 1 AC terminal x 2 33 Communication Battery terminal x 1 cable for BMS and Smart Meter x 1 Smart Meter x 1 Documents x 1 Lead-acid battery temperature sensor cable x1 Slotted screwdriver x The inverter that supports 1 connection to lead-acid battery will be provided with the cable. Lead-acid battery temperature sensor cable fixing sticker x 2 4.2.2 Battery Deliverables (LX A5.0-10) Parts Description Parts Description Battery module x (25-8) OT terminal x 4 1 (5.5-5) OT terminal x 2 M5 grounding Warning label x 1 screw x 2 Terminal resistor x Electrical label x 1 1 Battery bracket x 2 Documents x 1 (optional) 34 Support column x M4*8 screw x 8(optional) 2 (optional) When selecting stacking way to install the battery, the battery bracket, support column, and M4*8 screw are included in the package. 4.2.3 Battery Deliverables (LX A5.0-30) Parts Description Parts Description Terminal resistor x 1 When connecting to a third-party busbar, the Battery module x 1 battery needs to be equipped with this terminal resistor M5 OT terminal x 2: Recommended for connecting 10mm2 cable M8 OT terminal x 4: M5*12 grounding screw x Recommended for connecting 50mm 2 2 cable M10 OT terminal x 2: Recommended for connecting 70mm2 cable Documents x 1 - - Wall mounting rack x 2 M6*70 Expansion bolt x 4 For wall-mounted For wall-mounted installation installation M5*12 grounding Installation positioning screw x 2 cardboard x 1 For wall-mounted For wall-mounted installation installation 35 Battery bracket x 2 M4*8 screw x 8 (optional) For ground stacking For ground stacking installation installation 4.2.4 Battery Deliverables (LX U5.0-30) Parts Description Parts Description Battery x 1 Cover x 1 Mounting plate x 1 Expansion bolt x 2 (35-8) OT terminal x 4: Recommended for connecting 25mm2 or 35mm2 cable (50-8) OT terminal x 4: Recommended for Locking bracket x 2 connecting 50mm2 cable (70-10) OT terminal x 2: Recommended for connecting 70mm2 cable (14-5) OT Grounding M5 Screw x 7 terminal x 2 M10 Expansion Cable harness fixing bolt x 6 plate x 1 36 Documents x 1 Power connector protect cover x 2 Terminal resistor x - 1 - 4.2.5 Battery Deliverables (LX U5.4-L, LX U5.4-20) Parts Description Parts Battery x 1 Description Cover x 1 Mounting plate x Expansion bolt x 1 2 Locking bracket x Power connector 2 x2 Grounding M5 Screw x 8 terminal x 4 M10 Expansion Cable harness bolt x 6 fixing plate x 2 Terminal resistor x Terminal resistor 1(LX U5.4-L) x 1(LX U5.4-20) Documents x 1 4.2.6 Busbar (optional) BCB-11-WW-0 Parts Description Parts 37 Description M6 Expansion bolt x Busbar box x 1 4 (25-8) OT terminal x 18 (70-10) OT terminal x - - Parts Description 2 BCB-22-WW-0 Parts Description M6 Expansion bolt x Busbar box x 1 4 (25-8) OT terminal x 36 (70-10) OT terminal x - - 6 BCB-32-WW-0,BCB-33-WW-0 Parts Description Parts Busbar box x 1 Description M6 Expansion bolt x 4 (50-8) OT terminal x 30 (70-10) OT terminal x - - 6 4.2.7 Smart Meter Deliverables GMK110,GMK110D 38 Parts Description Parts Description Smart Meter x 1 RS485 GMK110: CT x 1 Communication GMK110D: CT x 2 terminal x 1 Voltage input side PIN terminal x 4 terminal x 1 Screwdriver x1 Documents x 1 GM1000,GM1000D,GM3000 Parts Description Parts Description Smart Meter x 1 GM1000: CT x 1 Screwdriver x1 GM1000D: CT x 2 GM3000: CT x 3 PIN terminal x N GM1000 x 4 USB port plug x 1 GM1000D x 8 GM3000 x 6 Documents x 1 - - GM330 Parts Description Parts Description Smart meter 2PIN terminal x1 and CT x 1 PIN terminal x 7PIN terminal x1 6 39 Screwdriver x1 6PIN terminal x1 2PIN terminal and RJ45 Documents x 1 terminal adapter cable x 1 4.2.8 Smart Dongle WiFi/LAN Kit-20 Parts Description Parts Smart dongle x 1 Description Documents x 1 Wi-Fi Kit Parts Quantity Parts Quantity Communication Documents x 1 module *1 Unlock tool x 1 Some smart dongle needs to be disassembled with the help of tools. If the tool is not provided, remove the module by pressing the unlock button on the module. LS4G Kit-CN&4G Kit-CN Parts Description Parts Description 4G Smart dongle x 1 - - Parts Description 4G Kit-CN-G20 & 4G Kit-CN-G21 Parts Description 40 Smart dongle x 1 Documents x 1 Ezlink3000 Parts Description Parts Smart dongle x 1 Description LAN cable connector x 1 Unlock tool x 1 Some smart dongle needs to be disassembled with the help of tools. If the Documents x 1 tool is not provided, remove the module by pressing the unlock button on the module. 4.3 Storage If the equipment is not to be installed or used immediately, please ensure that the storage environment meets the following requirements: The storage time of the inverter should not exceed two years. When the storage time exceeds two years, it needs to be inspected and tested by professional personnel before it can be put into use. Packing requirements: Do not unpack the outer package or throw the desiccant away. Installation Environment Requirements: 1. Place the equipment in a cool place away from direct sunlight. 2. Store the equipment in a clean place. Make sure the temperature and humidity are appropriate and there is no condensation. Do not install the equipment if the ports or terminals are condensed. Inverter Battery storage temperature range: LX A5.0-10/LX A5.0-30: When -20℃≤T﹤0℃ or 40℃﹤T≤45℃, the storage period cannot exceed 1 month. 41 When 0℃≤T≤40℃, the storage period cannot exceed 1 year. LX U5.4-L/LX U5.4-20: When -20℃≤T﹤0℃ or 35℃﹤T≤40℃, the storage period cannot exceed 1 month. When 0℃≤T≤35℃, the storage period cannot exceed 1 year. 3. Keep the equipment away from flammable, explosive, and corrosive matters. Stacking requirements: 1. The height and direction of the stacking inverters should follow the instructions on the packing box. 2. The inverters must be stacked with caution to prevent them from falling. Battery Dis-/Charge Requirements: Storage SOC: 25%-50% SOC. Circle the charge-discharge every 6 months. 5 Installation DANGER Install and connect the equipment using the deliverables included in the package. Otherwise, the manufacturer shall not be liable for the damage. 42 5.1 System Installation and Commissioning Procedure 5.2 Installation Requirements 5.2.1 Installation Environment Requirements 1. Do not install the equipment in a place near flammable, explosive, or corrosive materials. 2. The temperature and humidity at the installation site should be within the appropriate range. 3. Do not install the equipment in a place that is easy to touch, especially within children’s reach. 4. Do not touch the running equipment to avoid being hurt as its temperature may exceed 60°C. 5. Install the equipment in a sheltered place to avoid direct sunlight, rain, and snow. Build a sunshade if it is needed. 6. The place to install the equipment shall be well-ventilated for heat radiation and large enough for operations. 7. Check the protection rating of the equipment and ensure that the installation environment meets the requirements. The inverter, battery system, and smart dongle can be installed both indoors and outdoors. But the smart meter can only be installed indoors. 8. Install the equipment at a height that is convenient for operation and maintenance, electrical connections, and checking indicators and labels. 9. The altitude to install the equipment shall be lower than the maximum working altitude. 10. Consult the manufacturer before installing the equipment outdoors in salt affected areas. A salt 43 affected area refers to the region within 500 meters offshore, and will be related to the sea wind, precipitation and topography. 11. Install the equipment away from electromagnetic interference. If there are radio stations or wireless communication equipment below 30 MHz near the installation location, please install the equipment as follows: Inverter: add a multi-turn winding ferrite core at the AC output cable or DC output cable of the inverter, or add a low-pass EMI filter; or the distance between the inverter and the wireless electromagnetic interference device exceeds 30m. Other equipment: the distance between the equipment and the wireless EMI equipment should be more than 30m. NOTICE LX A5.0-30, LX U5.0-30: Charging temperature range: 0<T≤55℃; Discharging temperature range: -20<T≤55℃ LX A5.0-10, LX U5.4-L, LX U5.4-20: Charging temperature range: 0<T≤50℃; Discharging temperature range: -10<T≤50℃ 44 5.2.2 Installation Space Requirements Reserve enough space for operations and heat dissipation when installing the system. When using CAT7 communication cables among inverters, the maximum distance can reach 10 meters. While using CAT5 communication cables, the maximum distance can reach 5 meters. 45 5.2.3 Tool Requirements NOTICE The following tools are recommended when installing the equipment. Use other auxiliary tools on site if necessary. Installation Tools Tool Description Tool Diagonal pliers Description RJ45 crimping tool 46 Wire stripper YQK-70 hydraulic pliers PV connector tool Adjustable wrench PV-CZM-61100 Impact drill (drill bits Torque wrench Φ8mm, 10mm) M4、M5、M6、M8、M10 Rubber hammer Socket wrench set Multimeter Marker Range≤600V Heat shrink tube Heat gun Cable tie Vacuum cleaner Level - - Tool Description Personal Protective Equipment Tool Description Insulation gloves and Dust mask safety gloves 47 Goggles Safety shoes 5.3 Equipment Handling CAUTION Operations such as transportation, turnover, installing and so on must meet the requirements of the laws and regulations of the country or region where it is located. Move the inverter to the site before installation. Follow the instructions below to avoid personal injury or equipment damage. 1. Consider the weight of the equipment before moving it. Assign enough personnel to move the equipment to avoid personal injury. 2. Wear safety gloves to avoid personal injury. 3. Keep the equipment in balance during moving to avoid its falling down. 5.4 Installing the Inverter CAUTION Avoid the water pipes and cables buried in the wall when drilling holes. Wear goggles and a dust mask to prevent the dust from being inhaled or contacting eyes when drilling holes. Make sure the inverter is firmly installed in case of falling down. Step 1: Put the plate on the wall horizontally and mark positions for drilling holes. Step 2: Drill holes with hammer drill. Step 3: Use expansion bolts to fix the mounting plate on the wall. Step 4: Install the inverter on the mounting plate. Tighten the nuts to secure the mounting plate and the inverter. 48 5.5 Installing the Battery System WARNING Ensure that the battery system is installed vertically and securely. When using the locking bracket, the bracket should be vertically attached to the wall and the surface of the battery system. Cover the equipment with a cardboard to prevent foreign matters when drilling holes. Otherwise, the system may be damaged. After marking the drilling position with a marker pen, the battery system needs to be moved away to avoid equipment damage caused by the impact drill when drilling. LX A5.0-30:Stacking Installation NOTICE Up to 6 batteries can be stacked. Step 1: Place the battery vertically, and remove the battery handles. Step 2: Install brackets on the battery, and secure them with screws. Step 3: Place the battery flat and stack multiple batteries. Ensure that the locating pin is inserted into the locating hole. 49 LX A5.0-30:Cabinet Installation NOTICE It is recommended to install it in a 19-inch standard cabinet with a length*width of 600*800mm and above, and the height should be determined based on the thickness of the battery (133mm) and above. Electrical labels and warning labels need to be attached to any position of the front panel of the battery (these labels are shipped as additional accessories). Step 1: Place the battery on the guide rail of the cabinet and secure the battery with screws from the handle. 50 LX A5.0-30:Wall-mounted Installation Step 1: Determine the drilling position with installation positioning cardboard and marker pen. Step 2: Drill holes with hammer drill. Step 3: Install the battery brackets. Step 4: Install the battery on the brackets and secure the battery using screws. LX A5.0-10:Stacking Installation NOTICE 51 Up to 6 batteries can be stacked. LX A5.0-10:Cabinet Installation NOTICE It is recommended to use a 19-inch standard cabinet with length * width of 600*800mm and above. The height can be decided according to the number of batteries in parallel. Electrical labels and warning labels need to be attached to any position of the front panel of the battery (these labels are shipped as additional accessories). Step 1: Stick the electrical label and warning label to the position of the front panel of any battery. Step 2: Place the battery on the guide rail of the rack and secure the battery to the rack with screws from the handle. 52 LX U5.4-L, LX U5.4-20:Floor-mounted Installation NOTICE If parallel use is required, check and select batteries with similar production dates and numbers to use together. Step 1: Secure the locking bracket to the battery. Step 2: Keep the battery parallel to the wall and ensure that the locking bracket is tightly attached to the wall. Mark the drilling position with a marker pen, and remove the battery. Step 3: Use an impact drill to drill holes in the wall. Step 4: Tighten the expansion screw. 53 LX U5.4-L, LX U5.4-20: Wall-mounted Installation NOTICE Wall-mounted installation should be performed by 2 people. LX U5.0-30: Floor-mounted Installation 54 LX U5.0-30: Wall-mounted Installation 5.6 Installing the Smart Meter WARNING In areas at risk of lightning, if the meter cable exceeds 10m and the cables are not wired with grounded metal conduits, you are recommended to use an external lightning protection device. GMK110,GMK110D 55 GM1000,GM1000D,GM3000 56 6 System Wirings DANGER All operations, cables and parts specification during the electrical connection shall be in compliance with local laws and regulations. Disconnect the DC switch and the AC output switch of the inverter to power off the inverter before any electrical connections. Do not work with power on. Otherwise, an electric shock may occur. Tie the same type cables together, and place them separately from cables of different types. Do not place the cables entangled or crossed. If the cable bears too much tension, the connection may be poor. Reserve a certain length of the cable before connecting it to the inverter cable port. When crimping the terminals, ensure that the conductor part of the cable is in full contact with the terminals. Do not crimp the cable jacket with the terminal. Otherwise the inverter may not operate, or its terminal block getting damaged due to heating and other phenomenon because of unreliable connection after operation. NOTICE Wear personal protective equipment like safety shoes, safety gloves, and insulating gloves during electrical connections. All electrical connections should be performed by qualified professionals. Cable colors in this document are for reference only. The cable specifications shall meet local laws and regulations. Follow the safety precautions in the user manual of relevant products in the parallel system. 57 6.1 System Wiring Diagram NOTICE N and PE wiring ON-GRID and BACK-UP of the inverter are different based on the regulation requirements of different regions. Refer to the specific requirements of local regulations. There are built-in relays inside of the inverter’s ON-GRID and BACK-UP AC ports. When the inverter is in the off-grid mode, the built-in ON-GRID relay is disconnected; while when the inverter is in grid-tied mode, it is connected. When the inverter is powered on, the BACK-UP AC port is energized. Power off the inverter first if maintenance is required on the BACK-UP loads. Otherwise, it may cause electric shock. N and PE Cables are Wired Together in the Main Panel NOTICE To maintain neutral integrity, the N wires on the grid side and off grid side must be connected together, otherwise the off grid function cannot be used normally. Circuit diagram of power grid systems in regions such as Australia and New Zealand: N and PE Cables are Wired Separately in the Main Panel. 58 NOTICE Ensure that the grounding of BACK-UP is connected correctly and securely. Otherwise, the BACK-UP function may be abnormal in case of grid failure. Other areas except Australia, New Zealand are applicable to the following wirings: 6.2 Detailed System Wiring Diagram 6.2.1 Detailed System Wiring Diagram for Single Inverter System GM330 and other meters that meet the requirements can also be used in single inverter scenarios. Only the recommended types are shown here. With GMK110/GMK110D smart meter 59 With GM1000/GM3000 smart meter 60 6.2.2 Detailed System Wiring Diagram for Parallel System In parallel scenarios, the inverter connected to Ezlink and smart meter is considered as the master inverter, while all the others are slave inverters. Do not connect any smart dongle to the slave inverters. Generators are not supported in the parallel system. The following diagram mainly introduces parallel connections. For other port connections, refer to the single system. With GM1000 Smart Meter With GMK110 Smart Meter 61 6.3 Preparing Materials WARNING Do not connect loads between the inverter and the AC switch directly connected to the inverter. Install one AC output circuit breaker for each inverter. Multiple inverters cannot share one AC circuit breaker. An AC circuit breaker shall be installed on the AC side to make sure that the inverter can safely disconnect the grid when an exception happens. Select the appropriate AC circuit breaker in compliance with local laws and regulations. When the inverter is powered on, the BACK-UP AC port is energized. Power off the inverter first if maintenance is required on the BACK-UP loads. Otherwise, it may cause electric shock. For cables used in the same system, it is recommended that the conductor material, cross sectional area, length, etc. of the cables should be consistent. The AC cable for BACK-UP port of each inverter The AC cable for ON-GRID port of each inverter The power cable between inverter and battery The power cable between batteries The power cable between inverter and busbar The power cable between battery and busbar 62 The system only supports a single scenario where the generator is connected via the ATS switch to switch between grid and generator power. The ATS switch is connected to the grid by default. 6.3.1 Preparing Breakers No. Circuit Breaker Recommended specifications Comment The breaker specifications for the BACK-UP and ON-GRID for one inverter model shall be the same. Specification requirement: For GW3600M-ES-20: the nominal current is ≥20A and the nominal voltage is ≥230V. ON-GRID 1 For GW3000-ES-20, GW5000M-ES-20 and circuit breaker GW6000M-ES-20: the nominal current is ≥35A BACK-UP load and the nominal voltage is ≥230V. circuit breaker For GW3600-ES-20 and GW3600-ES-BR20: the Prepared by customers nominal current is ≥40A and the nominal voltage is ≥230V For GW3500L-ES-BR20, GW5000-ES-20, GW6000-ES-20 and GW6000-ESBR20: the nominal current≥63A and the nominal voltage≥230V The specifications for the ATS Switch and ON-GRID breaker for one inverter model shall be the same. Specification requirement: For GW3600M-ES-20: the nominal current is ≥20A and the nominal voltage is ≥230V. For GW3000-ES-20, GW5000M-ES-20 and 2 ATS Switch GW6000M-ES-20: the nominal current is ≥35A and the nominal voltage is ≥230V. For GW3600-ES-20 and GW3600-ES-BR20: the nominal current is ≥40A and the nominal voltage is ≥230V For GW3500L-ES-BR20, GW5000-ES-20, GW6000-ES-20 and GW6000-ESBR20: the nominal current≥63A and the nominal 63 Prepared by customers voltage≥230V Select according to local laws and regulations For GW3000-ES-20, GW3600M-ES-20, GW5000M-ES-20 and GW6000M-ES-20: the nominal current≥75A and the nominal Battery 3 breaker voltage≥60V. Prepared by For GW3600-ES-20, GW3500L-ES-BR20 and GW3600-ES-BR20: the nominal current is ≥100A customers and the nominal voltage is ≥60V. For GW5000-ES-20, GW6000-ES-20 and GW6000-ES-BR20: the nominal current is ≥150A and the nominal voltage is ≥60V. Select according to local laws and regulations 4 RCD Type A Prepared by ON-GRID: 300mA customers BACK-UP: 30mA 6.3.2 Preparing Cables No. 1 Cable Inverter PE cable Recommended specifications Obtain method Single-core outdoor copper cable Prepared by Cross-sectional area: 4-6mm² customers Single-core outdoor copper cable Prepared by Cross-sectional area: 2 Battery PE cable LX A5.0-10, LX U5.4-L, LX U5.4-20: 4mm²-6mm² LX A5.0-30, LX U5.0-30: 10mm² Commonly used outdoor photovoltaic cable 3 PV DC cable Cross-sectional area: 4mm²-6mm² Outer diameter: 5.9mm-8.8mm 4 Battery DC cable customers LX A5.0-30, LX U5.0-30: Supports purchase from GoodWe Prepared by customers Single-core outdoor copper cable Prepared by Wiring requirements for inverter battery customers ports: Cross-sectional area: 25mm²-35mm² Outer diameter: 15.7mm-16.7mm 64 LX A5.0-30, LX U5.0-30: supports Requirements for cables between battery and busbar: purchase from GoodWe LX A5.0-30, Cross-sectional area: 50mm² LX A5.0-10, LX U5.4-L, LX U5.4-20, LX U5.0-30, Conductor cross-sectional area: 25mm² Requirements for cables between batteries: LX A5.0-30, Cross-sectional area: 50mm² LX A5.0-10, LX U5.4-L, LX U5.4-20, LX U5.0-30, Conductor cross-sectional area: 25mm² (Note: when LX U5.0-30 is not connected to a busbar, recommended conductor cross-sectional area: 35mm²) Multi-cores or single-core outdoor copper wire, 5 6 BACK-UP/ON-G RID AC cable refer to the following table for specific specifications. Prepared by customers Smart meter Outdoor copper cable Prepared by power cable Cross-sectional area: 1mm² customers CAT 5E and above standard shielded network Prepared by cable and RJ45 shielded connector. customers Suitable for the following cables: LX A5.0-30, LX Communication cable between batteries U5.0-30 battery Smart meter RS485 communication cable communication Communication cable for inverters cable: Supports 7 connected in parallel. Communication EMS communication cable cable Charging Post Communication Cable purchase from GoodWe Copper core twisted pair cable, cross-sectional area: 0.2mm²-0.3mm² Suitable for the following cables: 8 Communication cable for load control Communication cable for generator control Communication cable for remote shutdown Communication cable for NS Protection 65 Prepared by customers Communication cable for RCR/DRED ※S:AC cable specifications requirement: No. Model S(ON-GRID) S(BACK-UP) 1 GW3000-ES-20 5mm² 2.5mm² 2 GW3600-ES-20 6mm² 2.5mm² 3 GW3600M-ES-20 2.5mm² 2.5mm² 4 GW5000-ES-20 10mm² 3mm² 5 GW5000M-ES-20 3mm² 3mm² 6 GW6000-ES-20 10mm² 5mm² 7 GW6000M-ES-20 5mm² 5mm² 8 GW3600-SBP-20 6mm² 2.5mm² 9 GW5000-SBP-20 10mm² 3mm² 10 GW6000-SBP-20 10mm² 5mm² 11 GW3500L-ES-BR20 6mm² 2.5mm² 12 GW3600-ES-BR20 10mm² 5mm² 13 GW6000-ES-BR20 10mm² 5mm² 6.4 Connecting the PE cable WARNING The PE cable connected to the enclosure of the inverter cannot replace the PE cable connected to the AC output port. Both of the two PE cables must be securely connected. Make sure that all the grounding points on the enclosures are equipotentially connected when there are multiple inverters. To improve the corrosion resistance of the terminal, it is recommended to apply silica gel or paint on the ground terminal after installing the PE cable. 66 Connect the PE cable first before installing the equipment. Disconnect the PE cable before dismantling the equipment. Inverter Battery 6.5 Connecting the PV Cable DANGER Do not connect one PV string to more than one inverter at the same time. Otherwise, it may 67 cause damage to the inverter. Confirm the following information before connecting the PV string to the inverter. Otherwise, the inverter may be damaged permanently or even cause fire and cause personal and property losses. 1. Make sure that the max short circuit current and the maximum input voltage per MPPT are within the permissible range. 2. Make sure that the positive pole of the PV string connects to the PV+ of the inverter. And the negative pole of the PV string connects to the PV- of the inverter. WARNING The PV strings cannot be grounded. Ensure the minimum insulation resistance of the PV string to the ground meets the minimum insulation resistance requirements before connecting the PV string to the inverter (R=maximum input voltage/ 30mA). Ensure the DC cables are connected tightly, securely, and correctly. Measure the DC cables with a multimeter to avoid reverse polarity connection. Also, the voltage should be under the permissible range. NOTICE The two input strings per MPPT should be of the same type, the same number of modules, the same tilt and angle to maximize efficiency. 68 6.6 Connecting the Battery Cable DANGER Do not connect one battery pack to more than one inverter at the same time. Otherwise, it may cause damage to the inverter. It is forbidden to connect loads between the inverter and batteries. When connecting battery cables, use insulated tools to prevent accidental electric shock or short circuit to the batteries. Ensure that the open circuit voltage of the battery is within the permissible range of the inverter. Install a DC breaker between the inverter and the battery in compliance with local laws and regulations. Battery system wiring diagram 69 LXA5.0-30: Hand-to-hand connection The battery system supports a maximum working current of 160A, working power of 8kW, and can be connected to a maximum of 1 inverter and 30 batteries. 70 LXA5.0-30: Connecting with the busbar BCB-22-WW-0 The battery system supports a maximum working current of 720A, working power of 36kW, and can be connected to a maximum of 6 inverters and 6 batteries. 71 LXA5.0-30: Connecting with the busbar BCB-32-WW-0 The battery system supports a maximum working current of 720A, working power of 36kW, and can be connected to a maximum of 6 inverters and 15 batteries. 72 LXA5.0-30: Connecting with the third-party busbar The complexity of the parallel system increases with the number of inverters. When the number of parallel inverters in the system is ≥ 6, contact the after-sales service center to confirm the installation and application environment of the inverters to ensure stable operation of the system. For a single battery, the nominal charging current is 60A, the nominal discharging current is 100A, the maximum charging current is 90A, and the maximum discharging current is 150A. A maximum of 30 batteries can be connected in parallel in one system. 73 LX A5.0-10: Hand-to-hand connection The nominal charging and discharging current of a single battery is 60A. The battery system supports a maximum working current of 120A, working power of 6kW, and can be connected to a maximum of 1 inverter and 2 batteries. 74 LX A5.0-10: Connecting with the busbar BCB-11-WW-0 The nominal charging and discharging current of a single battery is 60A. The battery system supports a maximum working current of 360A, working power of 18kW, and can be connected to a maximum of 3 inverters and 6 batteries. 75 LX A5.0-10: Connecting with the busbar BCB-22-WW-0 The nominal charging and discharging current of a single battery is 60A. The battery system supports a maximum working current of 720A, working power of 36kW, and can be connected to a maximum of 6 inverters and 12 batteries. 76 LX A5.0-10: Connecting with the third-party busbar The nominal charging and discharging current of a single battery is 60A. The complexity of the parallel system increases with the number of inverters. When the number of parallel inverters in the system is ≥ 6, contact the after-sales service center to confirm the installation and application environment of the inverters to ensure stable operation of the system. The battery system supports a maximum working current of 900A, working power of 45kW, and can be connected to a maximum of 15 batteries. 77 LX U5.4-L, LX U5.4-20: The nominal charging and discharging current of a single battery is 50A. The battery system supports a maximum working current of 100A, working power of 5kW, and can be connected to a maximum of 1 inverter and 6 batteries. It is recommended that the conductor material, cross sectional area, length, and etc. of the cables between inverters and batteries, and between batteries should be consistent. 78 LX U5.0-30: Hand-to-hand connection The nominal charging current of a single battery is 60A, and the nominal discharging current is 100A; the maximum charging current is 90A; the maximum discharging current is 100A. A maximum of 30 batteries can be connected in parallel in one system. The battery system supports a maximum working current of 160A, working power of 8kW, and can be connected to a maximum of 1 inverter and 30 batteries. LX U5.0-30: Connecting with the busbar BCB-32-WW-0 The battery system supports a maximum working current of 720A, working power of 36kW, and can be connected to a maximum of 6 inverters and 8 batteries. 79 LX U5.0-30: Connecting with the busbar BCB-33-WW-0 The battery system supports a maximum working current of 720A, working power of 36kW, and can be connected to a maximum of 6 inverters and 15 batteries. When the number of batteries exceeds 8, two 600A fuses need to be connected in parallel. 80 LX U5.0-30: Connecting with the third-party busbar When the battery quantity ≤ 8, the batteries can be directly connected to the busbar. 81 When 8<battery quantity ≤ 30, a fuse needs to be connected between the busbar and the inverter. Recommended specifications: nominal voltage>80V, nominal current ≥ 1.6 times the system nominal current, and Icu/Ics ≥ 50kA. 82 LX A5.0-30 Communication Port Definition PIN COM1 COM2 Description 1 - - 2 - - 3 Parallel OUT+ Parallel OUT+ 4 CAN_H CAN_H 5 CAN_L CAN_L battery parallel communication port. 6 Parallel OUT2+ Parallel OUT2+ Parallel interlock communication port. 7 - - 8 Parallel OUT- Parallel OUT- Reserved. Parallel communication port. Connect the inverter communication port or Reserved. Parallel communication port. LX A5.0-10 Communication Port Definition PIN COM1 COM2 1 - - 2 - - 3 Parallel OUT+ Parallel OUT+ 4 CAN_H CAN_H 5 CAN_L CAN_L 6 - - 7 - - 8 Parallel OUT- Parallel OUT- Description Reserved. Parallel communication port. Connect the inverter communication port or battery parallel communication port. Reserved. Parallel communication port. LX U5.4-L, LX U5.4-20 Communication Port Definition PIN COM1 COM2 1 RS485_A1 RS485_A1 2 RS485_B1 RS485_B1 Description Reserved. 83 3 - - Reserved. 4 CAN_H CAN_H 5 CAN_L CAN_L 6 - - Reserved. 7 - - Reserved. 8 - - Reserved. Connect the inverter communication port or battery parallel communication port. LX U5.0-30 Communication Port Definition PIN COM1 COM2 Description 1 RS485_A1 RS485_A1 2 RS485_B1 RS485_B1 3 Parallel OUT+ Parallel OUT+ 4 CAN_H CAN_H 5 CAN_L CAN_L 6 Parallel OUT 2+ Parallel OUT 2+ Parallel communication port. 7 - - Reserved. 8 Parallel OUT- RS485 Communication. Parallel communication port. Connect the inverter communication port or battery parallel communication port. Parallel OUT- Parallel communication port. 6.6.1 Connecting the Power Cable between the Inverter and Battery WARNING Measure the DC cables with a multimeter to avoid reverse polarity connection. Also, the voltage should be kept within the permissible range. Connect the battery cables to the corresponding terminals such BAT+, BAT- and grounding ports correctly. Otherwise it will cause damage to the inverter. Ensure that the whole cable cores are inserted into the terminal holes, and no part of the cable core can be exposed. Ensure that the cables are connected securely. Otherwise it will cause damage to the inverter due to overheat during its operation. Do not connect one battery pack to more than one inverter at the same time. Otherwise, it 84 may cause damage to the inverter. Overview of inverter and battery power cable connection Make the Inverter Power Cable Make the Battery Power Cable (LX A5.0-10 and LX A5.0-30) 85 Make the Battery Power Cable (LX U5.4-L and LX U5.4-20) Make the Battery Power Cable (LX U5.0-30) 86 6.6.2 Connecting the Communication Cable between the Inverter and Battery Instructions for BMS communication connection between the inverter and battery Inverter port Connected to the battery port Port Description Definition The inverter communicates with the battery through CAN. If the communication cable provided with the box cannot BMS(CAN) COM1 4: CAN_H 5: CAN_L meet the requirements, only PIN4 and PIN5 of the RJ connector should be crimped when crimping self-made cables, otherwise communication failure may occur. 87 NOTICE When connecting the lead-acid battery temperature sensor cable, it is recommended to connect the temperature sensor cable at a location with poor heat dissipation. For example, when lead-acid batteries are placed side by side, the sensor should be fixed on the lead-acid battery located in the middle. In order to better protect the battery cells, a temperature sampling cable must be installed, and it is recommended to place the battery in an environment with good heat dissipation. 88 6.7 Connecting the AC Cable WARNING The residual current monitoring unit (RCMU) is integrated into the inverter to avoid the residual current exceeds the limit. The inverter will disconnect the utility grid quickly once it found the residual current exceeds the limit. Connect the AC cables to the corresponding terminals such as “BACK- UP”, “ON-GRID”, ports correctly. Otherwise it will cause damage to the inverter. Ensure that the whole cable cores are inserted into the terminal holes, and no part of the cable core can be exposed. Ensure that the insulation board is inserted into the AC terminal tightly. Ensure that the cables are connected securely. Otherwise it will cause damage to the inverter due to overheat during its operation. Power off the inverter before operations and maintenance. Otherwise, the inverter may be damaged or electric shocks may occur. Do not connect 3 single-phase inverters to the three phases of the grid respectively in a parallel system. Otherwise, it will cause system error or damage to the inverters. Error case: the master inverter is connected to L1, slave inverter 1 is connected to L2, and slave inverter 2 is connected to L3 to form a three-phase system. Correct case: the master inverter is connected to L1, and the slave inverter is connected to L1. 89 Ensure that wiring sequences are the same. Do not connect L and N cables reversely on the ON-GRID port and on the BACK-UP port as well. Ensure all L and N cables are parallelized respectively on the BACK-UP port. For one parallel system, ensure the conductor’s materials, cross-sectional areas and lengths of AC cables between the Master Inverter and its slaves on the BACK-UP port and on the ON-GRID port, as well as the DC cables between the battery and the inverter, are the same. 6.8 Connecting the Meter Cable NOTICE Contact the manufacturer for additional smart meters if multiple inverters are connected. Ensure that the CT is connected in the correct direction and phase sequences, otherwise the monitoring data will be incorrect. Ensure all cables are connected tightly, securely, and correctly. Inappropriate wiring may cause poor contacts or high impedances, and damage the inverter. In areas at risk of lightning, if the meter cable exceeds 10m and the cables are not wired with grounded metal conduits, you are recommended to use an external lightning protection device. 90 Wiring of GMK110 NOTICE Outer diameter of the AC cable should be smaller than the holes diameter of the CT, so that the AC cable can be routed through the CT. To ensure accurate current detection, the CT cable is recommended to be shorter than 30m. Do not use network cable as the CT cable, otherwise the smart meter may be damaged due to high current. The CTs vary slightly in dimensions and appearance depending on the model, but they are installed and connected in the same way. GMK110 GMK110D Connection steps 91 GM1000 GM1000D GM3000 92 Connection steps Installing the CT (Type I) Installing the CT (Type II) 93 6.9 Connecting the Inverter Communication Cable NOTICE The communication functions are optional. Connect the cables based on actual needs. If you need to use the remote shutdown function, enable it in the SolarGo App after wiring is completed. Do not enable the remote shutdown function in the SolarGo App if the inverter is not connected to a remote shutdown device, otherwise the inverter will be unable to operate on-grid. In a parallel system, connect the communication cable to the master inverter to achieve the remote shutdown function, otherwise, the function will not work. To use the EnWG 14a, please ensure that the ARM software version is 13.435 or above, and the SolarGo version is 6.0.0 or above. The inverter supports communication with a mobile phone or WEB interface via Bluetooth, 4G, WiFi, or LAN smart dongle to set device parameters, view device operation information, error information, and keep abreast of system status. When the system contains multiple inverters, the main inverter needs to be installed with an Ezlink3000. When the energy storage system has only one inverter, WiFi-Kit, WiFi/LAN Kit-20, or 4G smart dongle can be used. When WiFi communication is selected to connect the inverter to a router, WiFi-Kit, WiFi/LAN Kit-20, or Ezlink3000 smart dongle can be used. When LAN communication is selected to connect the inverter to a router, WiFi/LAN Kit-20 or Ezlink3000 smart dongle can be used. When 4G communication is selected to upload the operation information of the energy storage system to the monitoring platform, LS4G Kit-CN, 4G Kit-CN, or 4G Kit-CN-G20 can be used. When using LS4G Kit-CN or 4G Kit-CN, you need to use the smart dongle delivered with the inverter to configure the parameters of the energy storage system. 94 After the configuration is completed, replace it with LS4G Kit-CN or 4G Kit-CN for data transmission. When using 4G Kit-CN-G20, please use the emitted Bluetooth signal to configure the near-end device. The 4G dongle is a LTE single-antenna device, applicable to scenarios with low data transmission rate requirements. The built-in SIM card of the 4G smart dongle is a mobile communication card. Please confirm whether the device is installed in an area covered by mobile 4G signals. The 4G Kit-CN-G20 smart dongle supports the replacement of operator communication cards. If the local mobile signal is not covered, please contact the after-sales service center to replace it with a communication card of another operator. After installing the 4G Kit-CN-G20, contact the after-sales service center to bind the inverter and the smart dongle. After binding, if you need to install the dongle to other inverters, please contact the after-sales service center to unbind it first. To ensure the quality of 4G signal communication, do not install the device indoors or in areas with signal interference of metal. To use the EnWG 14a, please ensure that the ARM software version is 13.435 or above, and the SolarGo version is 6.0.0 or above. Communication Descriptions 95 Port Function Description Support connecting dry contact signals to achieve load control and other functions. DO contact capacity is 12V DC@1A, NO/COM normally open contact. 1-3 Load Control Support SG Ready heat pump connection, to control the heat pump through dry contact signal. Supported working modes: Working mode 2 (signal: 0:0): Energy saving mode, in which the heat pump operates in energy-saving mode 96 Working mode 3 (signal: 0:1): It is recommended to activate. In this mode, the heat pump increases the hot water reserve to store heat while maintaining its current operation Provide signal control ports to remotely shut down the equipment or implement NS protection functions. Remote Shutdown Function: 4-5 Remote Control the inverter to stop when there is accident. Shutdown/NS The remote shutdown device needs to be a normally closed Protection switch. When using the RCR or DRED function of the inverter, ensure that the remote shutdown device is connected or the remote shutdown port is short-circuited. 6-7 Digital Signal Normally closed switch. The inverter supports access to remote Control commands, alarming or other DI signals via DI ports. Generator 8-9 start/stop controlling Port Support accessing the generator controlling signals. Do not connect the generator power cable to the inverter AC port. RCR (Ripple Control Receiver): Provide RCR signal control port to meet the power grid dispatch needs in German and DRED or RCR 10-15 other regions. DRED (Demand Response Enabling Device): Provide DRED functional signal control port to meet DERD certification requirements connection port in Australia and other regions. (DRED/RCR) EnWG (Energy Industry Act) 14a: All controllable loads need to accept the em dimming of the grid. Grid operators can reduce the maximum grid purchasab of controllable loads to 4.2kW temporarily. EMS EMS/PAR CAN and BUS Ports: parallel communication ports, using communicati CAN communication to connect to other inverters in on-grid on/charging scenarios; using BUS bus to control the parallel inverters in post on-grid and off-grid scenarios communicati on port RS485 Port: used to connect third-party EMS equipment and charging pile. The connection of third-party EMS devices and 97 Parallel charging piles is not supported in the parallel scenario communicati on port Connect to a temperature sensor cable when lead-acid Battery BMS BMS communication batteries are used. Connect to the BMS communication cable of the battery system and supports CAN signal communication when lithium-ion batteries are used. Meter METER communication Support the use of RS485 communication to connect external smart meters. Connecting the communication cable 98 7 System Power On 7.1 Check before Power ON No. Checking Item The product is firmly installed at a clean place that is well-ventilated and easy-to 1 2 operate. The PE, DC input, AC output, and communication cables are connected correctly and securely. 3 Cable ties are intact, routed properly and evenly. 4 Unused cable holes and ports should be sealed. 5 Used cable holes should be sealed. The voltage and frequency at the connection point meet the inverter grid 6 connection requirements. 7.2 Power ON WARNING When there are multiple inverters in the system, ensure that all slave inverter AC sides are powered on within one minute after the master inverter AC side is powered on. Battery black start scenarios: The inverter needs to be activated by battery. There is no inverter, but you need to control the battery, such as charge and discharge. Ensure that communication between the inverter and the battery system is normal within 15 minutes of starting the battery system. If the inverter cannot communicate normally with the battery system, the battery system breaker is automatically disconnected to shut down the system. LX U5.4-L, LX U5.4-20: press each battery button switch within 30 seconds. Otherwise the system will alarm. When there are multiple batteries in the system, starting any one of them can 99 start all the batteries. Power On: ❶→❷→❸→❹→❺ ❸: Install or not based on local laws and regulations. 100 7.3 Indicators 7.3.1 Inverter Indicators Indicator Status Description The inverter is powered on and in the standby mode. The inverter is starting up and in the self-check mode. The inverter is in normal operation under grid-tied or off-grid mode. BACK-UP output overload. A fault has occurred. The inverter is powered off. The grid is abnormal, and the power supply to the BACK-UP port of the inverter is normal. The grid is normal, and the power supply to the BACK-UP port of the inverter is normal. The BACK-UP port has no power supply The monitoring module of the inverter is resetting. The inverter fails to connect with the communication Termination. Communication fault between Termination and Server. The monitoring of the inverter operates well. The monitoring module of the inverter has not been started yet. Indicator Description 101 75%<SOC≤100% 50%<SOC≤75% 25%<SOC≤50% 0%<SOC≤25% No battery connected. Indicator light flashes during battery discharging: for example, when the battery SOC is between 25% and 50%, the light at the 50% position flashes. 7.3.2 Battery Indicators LX A5.0-30 Indicator System Status No SOC indicator shows SOC=0% green The first SOC indicator 0%<SOC≤25% shows green The first two SOC indicators are green The first three SOC 50%<SOC≤75% indicators are green The four SOC indicators are green 75%<SOC≤100% The battery system is working Steady green normally. Green light flashes 1 time/s RUN light 25%<SOC≤50% The battery system is in the standby mode. Green light flashes 3 times/s The PCS communication is lost Green flashes slowly flash The battery system gives an alarm, and 102 it will conduct a self-check. After the self-check is over, it will change to normal working status or fault status. Check the SOC indicator status to identify the fault type and handle the Steady red problem as recommended in the ALM Light Troubleshooting section. LX A5.0-10 Normal status SOC indicator RUN light Battery system status The SOC indicator represents the battery system's usable energy. Green flashes 1 The battery system is in time/s the standby mode. Green flashes 2 The battery system is in times/s an idle state. Steady green The battery system is in the charging state. The last SOC indicator flashes 1 time/s. When 5%≤SOC<25%, SOC 1 flashes. When 25% ≤ SOC < 50%, SOC2 flashes When 50% ≤ SOC < 75%, SOC3 flashes Steady green The battery system is in discharging status. When 75% ≤ SOC < 95%, SOC4 flashes. When 95% ≤ SOC ≤ 100%, SOC5 flashes Abnormal state ALM Light Battery system Description status 103 Once an alarm occurs, the battery system will Red blinks 1 time/s Battery system perform a self-check. After the battery alarms system self-check is complete, the battery system enters an operation or fault mode. Check the SOC indicator status to identify Steady red The battery system the fault type and handle the problem as has malfunctioned. recommended in the Troubleshooting section. LX U5.4-L Normal State SOC Indicator Button Indicator Battery Status SOC indicates the battery level Green flashes 1 The battery system is in time/s the standby mode. The last light flashes, and the rest steady on When 5%≤SOC<25%, SOC 1 flashes When 25% ≤ SOC < 50%, SOC2 Steady green flashes When 50% ≤ SOC < 75%, SOC3 flashes 104 The battery system is working. When 75% ≤ SOC < 95%, SOC4 flashes. When 95% ≤ SOC ≤ 100%, SOC5 flashes Abnormal Status Button Indicator Battery system Description state Check the SOC indicator status to identify Green flashes for 3s Battery system the fault type and handle the problem as alarm occurs. recommended in the Troubleshooting section. Check the SOC indicator status to identify Red flashes for 3s Battery system the fault type and handle the problem as malfunction. recommended in the Troubleshooting section. LX U5.4-20 Normal Status SOC Indicator Button Indicator Battery Status Green flashes 1 time/s The battery system is in the standby mode. SOC indicates the battery level Green flashes 2 time/s Steady green The battery system is in an idle state. The battery system is in a charging 105 state. The last light flashes, and the rest steady on. When 5%≤SOC<25%, SOC 1 flashes. When 25% ≤ SOC < 50%, SOC2 flashes. When 50% ≤ SOC < 75%, The battery system is in a Steady green discharging state. SOC3 flashes. When 75% ≤ SOC < 95%, SOC4 flashes. When 95% ≤ SOC ≤ 100%, SOC5 flashes. Abnormal Status Button Indicator Battery Status Description Check the SOC indicator status Battery system Red flashes 1 time/s alarms. to identify the fault type and handle the problem as recommended in the Troubleshooting section. Check the SOC indicator status The battery system Steady red has malfunctioned. to identify the fault type and handle the problem as recommended in the Troubleshooting section. LX U5.0-30 Indicator System Status 106 No SOC indicator shows SOC=0% green The first SOC indicator 0%<SOC≤25% shows green The first two SOC indicators are green The first three SOC 25%<SOC≤50% 50%<SOC≤75% indicators are green The four SOC indicators are green 75%<SOC≤100% The battery system is working Steady green properly. Green flashes 1 time/s The battery system is in standby mode. Green flashes 3 time/s The PCS communication is lost. RUN light The battery system gives an alarm, and it will conduct a self-check. After the Green flashes slowly self-check is over, it will change to normal working status or fault status. Check the SOC indicator status to identify the fault type and handle the Steady red problem as recommended in the ALM Light Troubleshooting section. 7.3.3 Smart Meter Indicator GMK110 Type Power indicator light Status Description On The smart meter is power on. Off The smart meter has been powered off. 107 Communication indicator Blinks Meter communication is normal Meter communication is abnormal or has no Off communication GM330 Type Status Description On Power on, no RS485 communication. Power indicator light Power on, RS485 communication works Blinks Communication properly. Off The smart meter has been powered off. Off Reserved indicator Press the Reset button for more than 5 Blinks seconds, power light, buying or selling electricity indicator light flash: reset the meter. Importing or exporting indicator On Importing from the grid. Blinks Exporting to the grid. Off No importing or exporting. Reserved 7.3.4 Smart Dongle Indicator WiFi/LAN Kit-20 NOTICE Double click the Reload button to turn on Bluetooth, and the communication indicator light will switch to a single flashing state. Connect the SolarGo App within 5 minutes. Otherwise Bluetooth will automatically turn off. The communication indicator light flashes once and only appears after double clicking the Reload button to turn on Bluetooth. 108 Indicator Description Status On: The smart dongle has been powered on. Power light Power Off: The smart dongle is not powered on. On: Communication in WiFi mode or LAN mode is normal. Blinks 1: The smart dongle Bluetooth has been turned on, and is waiting for connection to the SolarGo App. Blinks 2: The smart dongle is not connected to Communication the router. indicator Blinks 4: The smart dongle is communicating normally with the router, but has not been connected to the server. Blinks 6: The smart dongle is recognizing the connected device. Off: The software of the smart dongle is resetting or is not powered on. Indicator Color Description Status The 100Mbps wired network is On normally connected. The Ethernet cable is not Communication connected. Green indicator in LAN Fail to connect the 100Mbps wired Off network. Port The 10Mbps wired network is normally connected. The 10/100Mbps wired network is Yellow normally connected, but no On communication data is received or transmitted. Blinks The communication data is being 109 transmitted or received. Off The Ethernet cable is not connected. Description Button Press and hold for 0.5 to 3 seconds to reset the smart dongle. Press and hold for 6 to 20 seconds to restore the smart dongle to Reload factory settings. Quick double click to turn on the Bluetooth signal (only lasts 5 minutes) Wi-Fi Kit Indicator Color Power Status Description ON The Wi-Fi Kit is powered on. Green The Wi-Fi Kit is restarting or not OFF powered on. WiFi AP hotspot is connected. ON COM Wi-Fi Kit communication is Blue abnormal. OFF Wi-Fi Kit is restarting. LS4G Kit-CN、4G Kit-CN Indicator Color Power light Status Description On Module is tightened and powered up Off Module not tightened or powered up Green Inverter communication light 2 Communicati flashes: dialing in, looking for on indicator Blue network status Slow flash (0.2 on, 1.8s off) Inverter communication light 4 flashes: no traffic causing connection to the cloud to fail 110 Inverter communication light 2 flashes: dialing success Slow flash (1.8 on, Inverter communication light is always on: cloud connection is 0.2s off) successful Inverter communication light 4 flashes: no traffic causing connection to the cloud to fail Fast flash (0.125s on, 0.125s off) The inverter communicates with the cloud through the module SIM card not installed or poor SIM card 0.2s on, 8s off contact 4G Kit-CN-G20 & 4G Kit-CN-G21 Indicator Power Status Description On: The smart dongle has been powered on. light Power Off: The smart dongle is not powered on. On: The smart dongle is communicating normally with the server. Blinks 2 times: Smart dongle is not connected to the base station. Communi cation indicator Blinks 4 times: The smart dongle is connected to the base station, but has not been connected to the server. Blinks 6 times: The smart dongle is disconnected from the inverter. Off: The software of the smart dongle is resetting or is not powered on. 111 Button Description Short press for 0.5 to 3 seconds to restart the smart dongle. Reload Press and hold for 6 to 20 seconds to restore the Smart Dongle to factory settings. Ezlink3000 Indicator/ silkscreen Color Status Power light Description Blink = The Ezlink is working properly. Blue OFF = The Ezlink is powered off. ON = The Ezlink is connected to the server. Communica Blink 2 = The Ezlink is not connected to the tion indicator router. Green Blink 4 = The Ezlink is connected to the router, but not connected to the server. Short press for 3s to restart the Ezlink. RELOAD - - Long press for 3-10s to restore factory settings. 8 Quick System Commissioning 8.1 Downloading the App Make sure that the mobile phone meets the following requirements: Mobile phone operating system: Android 4.3 or later, iOS 9.0 or later. The mobile phone can access the Internet. The mobile phone supports WLAN or Bluetooth. 112 Method 1: Search SolarGo in Google Play (Android) or App Store (iOS) to download and install the app. Method 2: Scan the QR code below to download and install the app. 8.2 Connecting Inverter via SolarGo NOTICE The device name varies depending on the inverter model or smart dongle type: Wi-Fi Kit: Solar-WiFi*** Bluetooth module: Solar-BLE*** WiFi/LAN Kit-20: WLA-*** Ezlink3000: CCM-BLE***; CCM-*** 4G Kit-CN-G20 or 4G Kit-CN-G21: GSA-*** or GSB-*** *** is the inverter serial number* In a parallel system, connect the single inverter first to check the firmware version of each inverter. If the inverter version does not meet the requirements, contact the after-sales service center for an upgrade. In a parallel system, select the Ezlink signal to set the parameters of the main inverter, and the relevant parameters will be automatically synchronized to the slave inverter. If the parameters of the inverter cannot be kept consistent, connect the single inverter signal and set the parameters of the single inverter. Connect to the inverter via Bluetooth 113 Connecting the inverter via WiFi 114 8.3 Communication Settings NOTICE The communication configuration interface varies depending on the communication method. Step 1: Tap Home > Settings > Communication Settings > WLAN/LAN, to set the parameters. Step 2: Set the WLAN or LAN parameters based on actual situation. No. Name/Icon Description Applicable to WLAN. Please select the corresponding network based 1 Network Name on your actual situation and communicate the device with the router or switch. 2 Password Only for WLAN. WiFi password for the actual connected network. Enable DHCP when the router is in dynamic IP mode. 3 DHCP Disable DHCP when a switch is used or the router is in static IP mode. 4 IP Address 5 Subnet Mask Do not configure the parameters when DHCP is enabled. Gateway Configure the parameters according to the router or switch 6 7 Address information when DHCP is disabled. DNS Server 8.4 Quick Settings NOTICE The parameters will be configured automatically after selecting the safety country/region, including overvoltage protection, undervoltage protection, overfrequency protection, underfrequency protection, voltage/frequency connection protection, cosφ curve, Q(U) curve, P(U) curve, FP curve, HVRT, LVRT, etc. The power generation efficiency is different in different working modes. Set the working mode according to the local requirements and situation. 115 Description Parameters Safety Code Quantity Settings Select safety country accordingly. In parallel scenarios, set the number of inverters in the parallel system based on actual situation. Select the actual mode in which the battery is connected to the inverter. BAT Connect Mode There is no need to set the battery model and working mode if there is no battery is connected. The system will work in self-use mode by default. Select Battery Model Working Mode Select the actual battery model. Set the working mode based on actual needs. Supports: Peakshaving mode and Self-use mode. 116 The app interface is as following when Self-use mode is selected. Enter Advanced Settings to set the detailed working mode and related parameters. Description Parameters Self-use mode: based on the self-use mode, Back-up mode, TOU mode, and Smart charging can be enabled at the same time, and the inverter will automatically select the working mode. Working priority: Back-up mode> TOU mode >Smart charging>Self-use mode Back-up mode Charging From Grid Rated Power Enable Charging From Grid to allow power purchasing from the utility grid. The percentage of the purchasing power to the rated power of the inverter. TOU mode Start Time Within the Start Time and End Time, the battery is charged or discharged End Time according to the set Battery Mode as well as the Rated Power. Battery Mode Set the Battery Mode to Charging or Discharging accordingly. Rated Power Charge Cut-off SOC The percentage of the charging/discharging power to the rated power of the inverter. The battery stop charging/discharging once the battery SOC reaches 117 Charge Cut-off SOC. Smart charging Smart Charging Month Set the smart charging months. More than one month can be set. Set the Peak Limiting Power in compliance with local laws and Peak Limiting Power regulations. The Peak Limiting Power shall be lower than the output power limit specified by local requirements. Switch to Charge During charging time, the PV power will charge the battery. The app interface is as following when Peakshaving mode is selected. Description Parameters Peakshaving Start Time End Time The utility grid will charge the battery between Start Time and End Time if the load power consumption do not exceed the power quota. Otherwise, only PV power can be used to charge the battery. Set the maximum power limit allowed to be purchase from the grid. Import Power Limit When the loads consume power exceed the sum of the power generated in the PV system and Import Power Limit, the excess power will be made up by the battery. Reserved SOC For Peakshaving In Peak Shaving mode, the battery SOC should be lower than Reserved SOC For Peakshaving. Once the battery SOC is higher than Reserved SOC For Peakshaving, the peakshaving mode fails. Tap Complete to complete the settings, restart the equipment following the prompts. 118 8.5 Creating Power Plants NOTICE Login to the SEMS Portal app using the account and password before creating power plants. If you have any questions, refer to the Plant Monitoring section. Step 1 Enter the Create Plant page. Step 2 Read the instructions and fill in the requested plant information based on actual situation. (* refers to the mandatory items) Step 3 Follow the prompts to add devices and create the plant. 119 120 9 System Commissioning 9.1 SolarGo Overview SolarGo App is a mobile application that communicates with the inverter through bluetooth or WiFi modules. Commonly used functions are as follows: 1. Check the operating data, software version, alarms, etc. 2. Set grid parameters, communication parameters, safety countries, power limitation, etc. 3. Equipment maintenance. 4. Upgrade the firmware version of the equipment. 9.1.1 Menu Structure of the App 121 9.1.2 Login Page of SolarGo App No. Name/Icon Description 1 Tap the icon to open the page downloading the SEMS Portal app. 2 Tap to read the connection guide. Not found Check information such as app version, local contacts, etc. Other settings, such as update date, switch language, set 3 temperature unit, etc. 4 Bluetooth/W LAN Select based on actual communication method. If you have any problems, tap or NOT Found to read the connection guides. The list of all devices. The last digits of the device name are normally the serial number of the device. 5 Device List Select the device by checking the serial number of the master inverter when multi inverters are parallel connected. The device name varies among different inverter models or communication modules. 122 6 Search Device Tap Search Device if the device is not found. 9.1.3 Home Page of SolarGo App Single Inverter Multiple Inverters No. Name/Icon 1 Serial Number 2 Device Status Indicates the status of the inverter, such as Working, Fault, etc. Energy Flow Indicates the energy flow chart of the PV system. The actual page 3 Chart Description Serial number of the connected inverter or serial number of the master inverter in the parallel system. prevails. Indicates the system status, such as Safety Code, Working Mode, 4 System Status Battery Model, Battery Status, Power Limit, Three-Phase Unbalanced Output, etc. Home. Tap Home to check Serial Number, Device Status, Energy Flow 5 Home Chart, System Status, etc. Parameters. Tap Parameters to check the running parameters of the 6 Parameters system. 123 Settings. Log in before entering Quick Settings and Advanced Settings. 7 Settings 8 Parallel Initial password: goodwe2010 or 1111. Tap Total Number to check serial number of all inverters. Tap the serial number to enter the setting page of the single inverter. 9.2 Connecting Inverter via SolarGo NOTICE The device name varies depending on the inverter model or smart dongle type: Wi-Fi Kit: Solar-WiFi*** Bluetooth module: Solar-BLE*** WiFi/LAN Kit-20: WLA-*** Ezlink3000: CCM-BLE***; CCM-*** 4G Kit-CN-G20 or 4G Kit-CN-G21: GSA-*** or GSB-*** *** is the inverter serial number* In a parallel system, connect the single inverter first to check the firmware version of each inverter. If the inverter version does not meet the requirements, contact the after-sales service center for an upgrade. In a parallel system, select the Ezlink signal to set the parameters of the main inverter, and the relevant parameters will be automatically synchronized to the slave inverter. If the parameters of the inverter cannot be kept consistent, please connect the single inverter signal and set the parameters of the single inverter. Connect to the inverter via Bluetooth 124 Connecting the inverter via WiFi 125 9.3 Quick Settings NOTICE The parameters will be configured automatically after selecting the safety country/region, including overvoltage protection, undervoltage protection, overfrequency protection, underfrequency protection, voltage/frequency connection protection, cosφ curve, Q(U) curve, P(U) curve, FP curve, HVRT, LVRT, etc. The power generation efficiency is different in different working modes. Set the working mode according to the local requirements and situation. Description Parameters 126 Safety Code Quantity Settings Select safety country accordingly. In parallel scenarios, set the number of inverters in the parallel system based on actual situation. Select the actual mode in which the battery is connected to the inverter. No BAT Connect Mode need to set the battery model and working mode if there is no battery is connected. The system will work in self-use mode by default. Select Battery Model Working Mode Select the actual battery model. Set the working mode based on actual needs. Supports: Peakshaving mode and Self-use mode. The app interface is as following when Self-use mode is selected. Enter Advanced Settings to set the detailed working mode and related parameters. Description Parameters Self-use mode: based on the Self-use mode, Back-up mode, Economic mode, and Smart charging can be enabled at the same time, and the inverter will automatically select the working mode. Working priority: Back-up mode> TOU mode >Smart charging>Self-use mode Back-up mode Charging From Grid Rated Power Enable Charging From Grid to allow power purchasing from the utility grid. The percentage of the purchasing power to the rated power of the 127 inverter. TOU mode Start Time Within the Start Time and End Time, the battery is charged or discharged End Time according to the set Battery Mode as well as the Rated Power. Battery Mode Set the Battery Mode to Charging or Discharging accordingly. Rated Power Charge Cut-off SOC The percentage of the charging/discharging power to the rated power of the inverter. The battery stop charging/discharging once the battery SOC reaches Charge Cut-off SOC. Smart charging Smart Charging Month Set the smart charging months. More than one month can be set. Set the Peak Limiting Power in compliance with local laws and Peak Limiting Power regulations. The Peak Limiting Power shall be lower than the output power limit specified by local requirements. Switch to Charge During charging time, the PV power will charge the battery. The app interface is as following when Peakshaving mode is selected. Description Parameters Peakshaving Start Time End Time The utility grid will charge the battery between Start Time and End Time if the load power consumption do not exceed the power quota. Otherwise, only PV power can be used to charge the battery. 128 Set the maximum power limit allowed purchase from the grid. When Import Power Limit the loads consume power exceed the sum of the power generated in the PV system and Import Power Limit, the excess power will be made up by the battery. Reserved SOC For Peakshaving In Peak Shaving mode, the battery SOC should be lower than Reserved SOC For Peakshaving. Once the battery SOC is higher than Reserved SOC For Peakshaving, the peakshaving mode fails. Tap Complete to complete the settings,following the prompts to restart the equipment. 9.4 Communication Settings NOTICE The communication configuration page varies depending on the communication method. Step 1: Enter the setting page through "Home" > "Settings" > "Communication Configuration" > "Network Settings". Step 2: Configure the WLAN or LAN network based on the actual situation. Number Name/Icon Description Applicable to WLAN. Please select the corresponding network 1 Network Name based on your actual situation and communicate the device with the router or switch. 129 Password 2 Applicable to WLAN. Enter the password for the network you actually selected. When the router is using the dynamic IP mode, turn on the DHCP 3 DHCP function. When using the router in static IP mode or using a switch, turn off the DHCP function. 4 IP address 5 Subnet mask 6 Gateway address 7 DNS Server When DHCP is enabled, there is no need to configure this parameter. When DHCP is turned off, please configure this parameter according to the information of the router or switch. 9.5 Setting the Basic Information 9.5.1 Setting Shadow Scan and SPD Step 1 Tap Home > Settings > Basic Settings, to set the parameters. Step 2 Set the functions based on actual needs. Shadow Scan and SPD No. Parameters Description Enable Shadow Scan when the PV panels are 1 Shadow Scan severely shadowed to optimize the power generation efficiency. After enabling SPD, when the SPD module is 2 SPD abnormal, there will be SPD module abnormal alarm prompt. BACKUP After setting the backup power function, when the grid is cut off, the load connected to the inverter's BACKUP port can be powered by the battery to ensure uninterrupted power supply to the load. No. Parameters Description 130 1 2 3 UPS Mode - Full Wave Detection UPS Mode - Half Wave Detection EPS Mode Supports LVRT Check whether the utility grid voltage is too high or too low. Check whether the utility grid voltage is too low. Stop detecting utility grid voltage. Once the power of loads connected to the inverter BACK-UP ports exceeds the nominal load power, the inverter will restart and detect the power again. The inverter will perform 4 Clear Overload restart and detection several times until the overloading History problem is solved. Tap Clear Overload History to reset the restart time interval after the power of the loads connected to the BACK-UP ports meets the requirements. The inverter will restart immediately 9.5.2 Setting Advanced Parameters Step 1: Tap Home > Settings > Advanced Settings to set the parameters. Step 2: Set the parameters based on actual needs. Tap‘√’or Save to save the settings. The parameters are set successfully. No. Parameters Description AFCI Test Enable or disable AFCI accordingly. AFCI Test Status 1 2 AFCI Test succeeded, etc. Clear AFCI Alarm Clear ARC Faulty alarm records. Self-check Tap to check whether the AFCI function works normally. Stand-alone The PV strings are connected to the MPPT terminals Connect one by one. The PV strings are connected to the inverter in both PV Connect Mode The test status, like Not Self-checking, self-check Partial Parallel stand-alone and parallel connection. For example, one Connect PV string connect to MPPT1 and MPPT2, another PV string connect to MPPT3. 131 Parallel Connect 3 Battery port busbar connection The external PV string is connected to multi MPPT terminals of the inverter. Enable the function if a busbar is connected to the system. 9.5.3 Setting Power Limit Parameters Step 1 Tap Home > Settings > Advanced Settings > Power Limit to set the parameters. Step 2 Enable or disable the power limit function based on actual needs. Step 3 Enter the parameters and tap √. The parameters are set successfully. No. Parameters 1 Power Limit 2 Export Power (W) 3 External CT Ratio Description Enable Power Limit when power limiting is required by local grid standards and requirements. Set the value based on the actual maximum power fed into the utility grid. Set the ratio of the primary current to the secondary current of the external CT. 9.5.4 Setting the Battery Parameters Lithium battery Step 1 Tap Home > Settings > Advanced Settings > Battery Function to set the parameters. Step 2 Enter the parameters and tap √. The parameters are set successfully. No. Parameters Description 1 Max. Charging Current Set the maximum charging current based on actual needs. 2 Max. Discharging Current Set the maximum discharging current based on actual needs. 3 SOC Protection Start battery protection when the battery capacity is lower than the Depth of Discharge. Depth of 4 discharge(on-grid) Indicates the depth of discharge of the battery when the inverter is on-grid or off-grid. 5 Depth of 132 discharge(off-grid) The battery will be charged to preset SOC protection value by 6 Backup SOC Holding utility grid or PV when the system is running on-grid, so that the battery SOC is sufficient to maintain normal working when the system is off-grid. 7 8 Immediate Charging Enable to charge the battery by the grid immediately. Take effect once. Enable or Disable based on actual needs. SOC For Stopping Stop charging the battery once the battery SOC reaches SOC Charging For Stopping Charging. Indicates the percentage of the charging power to the Immediate Charging 9 Power inverter nominal power when enabling Immediate Charging. For example, setting the Immediate Charging Power of a 10kW inverter to 60 means the charging power of the inverter is 10kW*60%=6kW. Optional. This option is displayed on the interface when a battery that supports heating is connected. After the battery heating function is turned on, when the temperature is below the value that starts up the battery, PV power or electricity from the grid will be used to heat the battery. Heating Mode: 10 Economic Mode: to maintain the minimum power input capacity of the battery. It will be turned on when the Battery Heating temperature is less than 5℃, and turned off when it is greater than or equal to 7℃. Standard Mode: to maintain the moderate power input capacity of the battery. It will be turned on when the temperature is less than 10℃, and turned off when it is greater than or equal to 12℃. Efficient Mode: to maintain the higher power input capacity of the battery. It will be turned on when the 133 temperature is less than 20℃, and turned off when it is greater than or equal to 22℃. This function can only be set through the App. After the function is enabled, the battery can be awakened when it shuts down due to under-voltage protection. 11 Battery Wake-up Only applicable to lithium batteries without circuit breakers. After being enabled, the output voltage of the battery port is around 60V. Lead Acid Battery NOTICE 1. Before setting the parameters of lead-acid batteries, it is necessary to read the user manual, technical parameters and other related materials of lead-acid batteries. To ensure the safety of batteries, please strictly follow the relevant materials of lead-acid battery manufacturers to set the battery parameters. Otherwise, the risks caused thereby shall not be within the scope of the responsibility of the inverter manufacturer. 2. The voltage range of lead-acid batteries needs to match the inverter, and the recommended voltage of lead-acid batteries connected to the inverter is ≤60V, otherwise the inverter may not operate properly. 3. The SOC of lead-acid batteries is calculated by the inverter BMS, not the actual battery capacity, which may result in SOC value deviation or jump. SOC is only used as a reference for battery capacity. Performing SOC value calibration after the battery is fully charged can improve the accuracy of the SOC value. Step 1: Enter the parameter settings interface through Home > Settings > Advanced Settings > Battery Function. Step 2: Enter the parameters and tap √. The parameters are set successfully. Number 1 Parameter Battery Capacity Description Set the parameter according to the battery technical parameters. When the battery is approaching full charge, it 2 Floating Voltage will switch to float charging mode. This value is the upper limit of charging voltage in this mode. 134 Set the parameter according to the battery technical parameters. The battery charging mode is set to constant 3 Constant Charging Voltage voltage charging by default; this value is the upper limit of charging voltage in this mode. Set the parameter according to the battery technical parameters. Set the parameter according to the battery 4 Minimum discharge technical parameters.To protect the battery voltage performance and life, this parameter should not be set too low. 5 Max. Charging Current The maximum current during charging, used to limit the charging current. Set the parameter according to the battery technical parameters. Set the parameter according to the battery 6 Max. Discharging technical parameters. The greater the discharge Current current is, the shorter the working time of the battery is. The maximum charging current in the floating charge state. Set the parameter according to the 7 Maximum floating charge current battery technical parameters. When the battery is nearly fully charged, it will enter the floating charge state. Please refer to the technical parameters of the corresponding battery model for specific definitions. 8 Battery Internal Resistance The internal resistance of the battery. Set the parameter according to the battery technical parameters. When the battery charging status changes from 9 Time to switch to float charging mode constant charging to float charging, and the duration reaches the set value, the battery charging mode will switch to float charging mode. The default duration is 180s. 10 Charge temperature By default, when the temperature is higher than compensation 25℃, the upper limit of charging voltage will 135 decrease by 3mV for every 1℃ increase. The actual settings should be based on the technical parameter of the battery. 9.5.5 Setting Generator Parameters Step 1: After connecting to the SolarGo APP, go to Home > Settings > Port Connection > Generator Connection. After selecting the generator type, enter the parameter setting interface. Step 2: Enter the parameters and tap √. The parameters are set successfully. Manual control generator (does not support dry contact connection): This type of generator only supports manual start and stop. Automatic control generator (support dry contact connection): This type of generator supports automatic start and stop. Number Parameter Description Set the switch control mode and automatic control mode. In the switch control mode, the start and stop of the 1 Dry contact control generator can be remotely controlled. In automatic control mode mode, the generator automatically starts and stops based on preset parameters. This feature only applies to generators that support dry contact connection. Set a prohibited working time. During this period, the 2 No working time generator will stop working. This feature only applies to generators that support dry contact connection. 3 Rated power Rated power of the generator. The duration of continuous operation of a generator. 4 Running time When the working time exceeds the set value, the generator will automatically shut down. This feature only applies to generators that support dry contact connection. 5 Upper Voltage Set the up 的改 136 per limit of operating frequency for the generator. The time mode will be on between the Start Time and End 6 Lower Voltage Time. Set the upper limit of operating frequency for the generator. 7 Upper frequency 8 Lower Frequency 9 Preheating time 10 Switch Set the upper limit of operating frequency for the generator. Set the lower limit of the generator's operating frequency. The no-load preheating time before the generator is loaded. Turn on or off the function of the generator to charge the battery. Maximum charging 11 Set the maximum charge power for the generator battery. power Set the start voltage for generator to charge battery. When 12 Starting voltage the voltage of the battery is lower than the set value, the generator will charge the battery. Set the stop voltage for generator to charge battery. When 13 Stop voltage the voltage of the battery is higher than the set value, the generator will stop charging the battery. 9.5.6 Setting Load Control Step 1: After connecting to the SolarGo APP, enter the parameter setting interface through Home > Settings > Port Connection > Load Control. Step 2: Enter the parameters and tap √. The parameters are set successfully. Number Parameter 1 Dry Contact Mode Description The loads will be powered within the setting time period. When the switch is ON, the loads will be powered; when the 137 switch is OFF, the power will be cut off. Turn the switch on or off based on actual needs. 2 Time Mode Set the time to enable the load, and the load will be powered automatically within the setting time period. The inverter has an integrated relay controlling port, which can control the loads off or on. In off-grid mode, the load 3 SOC mode connected to the port will not be powered if the BACKUP overload is detected or the battery SOC value is lower than the Off-grid battery protection value. 9.6 Setting Safety Parameters 9.6.1 Setting the Basic Safety Parameters NOTICE The grid standards of some countries/regions require that inverters shall set functions to meet local requirements. Step 1: Tap Home > Settings > Advanced Settings, to set the parameters. Number Parameter DRED/Remote 1 Shutdown/RCR/EnWG 14a Three-phase 2 Unbalanced Output Description Enable DRED/Remote Shutdown/RCR/EnWG 14a before connecting the third party DRED, remote shutdown, or RCR device to comply with local laws and regulations. Enable Three-phase Unbalanced Output when the utility grid company adopts phase separate billing. To comply with local laws and regulations, ensure 3 Backup N and PE Relay that the relay inside the back-up port remains Switch closed and the N and PE wires are connected when the inverter is working off-grid. 138 Enable AUTO TEST to set auto test for grid tying in 4 Auto Test compliance with local grid standards and requirements. 9.6.2 Setting Customized Safety Parameters NOTICE Set the custom safety parameters in compliance with local requirements. Do not change the parameters without the prior consent of the grid company. 9.6.2.1 Setting the Active Power Mode Setting the P(F) Curve Step 1: Tap Home > Settings > Advanced Settings > Safety Parameters > Active Power Mode Settings to set the parameters. Step 2: Set the parameters based on actual needs. Setting the P(U) Curve Step 1: Tap Home > Settings > Advanced Settings > Safety Parameters > Active Power Mode Settings to set the parameters. Step 2: Enter the parameters. The inverter will adjust the active output power to the apparent power ratio in real-time according to the actual grid voltage to the nominal voltage ratio. 139 9.6.2.2 Setting the Reactive Power Mode Setting the Fix PF Step 1: Tap Home > Settings > Advanced Settings > Safety Parameter Settings > Reactive Power Mode to set the parameters. Step 2: Set the parameter based on actual needs. The power factor remains fixed during the inverter working process. Number Parameter 1 Fix PF 2 Under-excited 3 Over excitation 4 Power Factor Description Enable Fix PF when it is required by local grid standards and requirements. Set the power factor as lagging or leading based on actual needs and local grid standards and requirements. Set the power factor based on actual needs. Range: -1~-0.8, or +0.8~+1. Setting the Fix Q Step 1: Tap Home > Settings > Advanced Settings > Safety Parameter Settings > Reactive Power Mode to set the parameters. Step 2: Set the parameter based on actual needs. The output reactive power remains fixed during the inverter working process. 140 Number Parameter 1 Fix Q 2 Under-excited Description Enable Fix Q when it is required by local grid standards and requirements. Set the reactive power as inductive or capacitive reactive power based on actual needs and local grid standards 3 Over excitation 4 Power Factor and requirements. The percentage of reactive output power to apparent power. Setting the Q(U) Curve Step 1: Tap Home > Settings > Advanced Settings > Safety Parameter Settings > Reactive Power Mode to set the parameters. Step 2: Enter the parameters. The inverter will adjust the reactive power to the apparent power ratio in real-time according to the actual grid voltage to the nominal voltage ratio. Setting the Cosφ Curve Step 1: Tap Home > Settings > Advanced Settings > Safety Parameter Settings > Reactive Power Mode to set the parameters. Step 2: Enter the parameters. The inverter will adjust the active output power to the apparent power ratio in real-time according to the actual grid voltage to the nominal voltage 141 ratio. Setting Protection Parameters Step 1: Tap Home > Settings > Advanced Settings > Safety Parameters > Protection Parameters to set the parameters. Step 2: Set the parameters based on actual needs. Number Parameter Description Voltage Protection Parameters 1 OV Stage n Trip Value 2 OV Stage n Trip Time 3 UV Stage n Trip Value 4 UV Stage n Trip Time 5 Grid 10min Overvoltage Set the grid overvoltage protection threshold value, n = 1, 2, 3. Set the grid overvoltage protection tripping time, n = 1, 2, 3. Set the grid undervoltage protection threshold value, n= 1, 2, 3. Set the grid undervoltage protection tripping time, n = 1, 2, 3. Set the 10min overvoltage protection threshold value. Frequency Protection Parameters 142 6 OF Stage n Trip Value 7 OF Stage n Trip Time 8 UF Stage n Trip Value 9 UF Stage n Trip Time Set the grid overfrequency protection threshold value, n = 1, 2. Set the grid overfrequency protection tripping time, n = 1, 2. Set the grid underfrequency protection threshold value, n = 1, 2. Set the grid underfrequency protection tripping time, n = 1, 2. Setting Connection Parameters Step 1: Tap Home > Settings > Advanced Settings > Safety Parameters > Connection Parameters to set the parameters. Step 2: Set the parameters based on actual needs. Setting Voltage Ride through Parameters Step 1: Enter the parameter setting page through Home > Settings > Advanced Settings > Safety Parameter Settings > Voltage Fault Ride-Through. Step 2: Set the parameters based on actual needs. 143 Number Parameters Description LVRT 1 2 Ride Through Voltage The inverter will not be disconnected from the utility Start Point grid immediately when the grid voltage is between Ride Through Voltage End Ride Through Voltage Start Point and Ride Through Point Voltage End Point. Ride Through Time Start 3 Point Ride Through Time End 4 5 Point Indicates the longest duration the inverter can remain connected to the grid when the grid voltage is at the Ride Through Voltage Start Point. Indicates the longest duration the inverter can remain connected to the grid when the grid voltage is at the Ride Through Voltage End Point. Ride Through Trip LVRT is allowed when the grid voltage is lower than Threshold Ride Through Trip Threshold Ride Through Voltage The inverter will not be disconnected from the utility Start Point grid immediately when the grid voltage is between Ride Through Voltage End Ride Through Voltage Start Point and Ride Through Point Voltage End Point. HVRT 6 7 Ride Through Time Start 8 Point Ride Through Time End 9 10 Point Indicates the longest duration the inverter can remain connected to the grid when the grid voltage is at the Ride Through Voltage Start Point. Indicates the longest duration the inverter can remain connected to the grid when the grid voltage is at the Ride Through Voltage End Point. Ride Through Trip HVRT is allowed when the grid voltage is higher than Threshold Ride Through Trip Threshold 144 10 Monitoring Power Plant 10.1 SEMS Portal Overview SEMS Portal App is a monitoring platform. Commonly used functions are as follows: 1. Manage the organization or User information; 2. Add and monitor the power plant information; 3. Equipment maintenance. Login Page of SEMS Portal App Number Name Description 1 Login Area Enter the user name, password to login to the app. 2 Forget Password Tap to reset the password by verifying the account. Tap to enter the sample plant page. The sample page 3 Demo only displays contents with Visitor account, which is for reference only. 145 Configure WiFi parameters to establish communication 4 Configuration between the inverter and the server and realize remote monitoring and managing. Tap to register an end-user account. Contact the 5 Register manufacturer or the company as prompted if you need a company account. 6 APPs Tap to download SolarGo app. Introduction to the Home Page Interface of SEMS Portal App Number Name Create power plant. 1 2 Description Power plant Display the current operating status of the power plant. 146 operation status Search for power 3 plant Power 4 generation statistics Search for power stations by selecting their name, equipment SN number, email, or on the map. Click to switch between today, this month, total generated power and cumulative earnings. Home of power plant monitoring. 5 Plants Alarms. Check all alarms, happening alarms, and recovered 6 Alarms alarms. When using Wi-Fi Kit on the device, this button can be used to 7 WiFi set up WiFi related settings. Discovery. To Edit the account, create My QR Code, set 8 Discovery 9 Income Settings, etc. Message. Set and check system messages. Message 10.2 Manage Power Plant or Equipment 10.2.1 Creating the Power Plant Step 1: Enter the interface for creating a power plant. Step 2: Carefully read the prompts and fill in the power plant information based on actual conditions. (* refers to the mandatory items) 147 Step 3: Add devices according to the interface prompts to complete the creation of the power plant. 10.2.2 Managing the Power Plant Step 1: Enter the power plant monitoring page and delete or modify the power plant information based on actual needs. 148 10.2.3 Managing the Equipment in the Power Plant Step 1: Tap the power plant to enter the power plant details page. Step 2: Tap the serial number of the device to enter the device details page, and add, delete, or replace the device based on actual needs. 149 10.3 Power Plant Monitoring 10.3.1 Viewing Power Plant Information After logging into SEMS Portal App with the account and password, you will enter the home page of the power plant, where the overall operation status of all power plants under the account will be displayed. Tap Monitoring to enter the power plant monitoring interface to view all power plant information. The displayed content of different interfaces of power plant equipment varies. Step 1: (Optional) if there are multiple power plants, you can search for information such as the power plant name, inverter SN number, or the owner's phone number to quickly locate the power plant. Or tap the map sign to search for power plant information and quickly locate the power plant. Step 2: Tap the power plant name in the power plant list or the power plant icon on the map to view the detailed information of the power plant. Step 3: Check the power plant information, power generation details, equipment information, faults, and other conditions according to the prompts on the interface. 150 10.3.2 Checking Alarms Step 1 Tap Alarm tab and enter the Alarm Details page. Step 2 (Optional) Enter the plant name, inverter SN, or owner’s Email address in the search bar to find out the plant which is alarming. Step 3 Tap the alarm name to check the alarm details. 151 152 11 Maintenance 11.1 Power OFF the System DANGER Power off the equipment before operations and maintenance. Otherwise, the equipment may be damaged or electric shocks may occur. Delayed discharge. Wait until the components are discharged after power off. Push the air switch to restart the battery. Strictly follow the power off requirements to avoid damaging the system When there are multiple batteries in the system, powering off any one of the batteries can power off all the batteries. NOTICE Install the circuit breaker between the inverter and the battery or between the two batteries in compliance with local laws and regulations. To ensure effective protection, the cover of the battery system switch should remain closed. The cover can be closed automatically after being opened. Fasten the cover with screws if the switch is not to be used for a long-term period. 153 Power Off: ❶→❷→❸→❹→❺ ❸: Install or not based on local laws and regulations. 11.2 Removing the Equipment DANGER Make sure that the equipment is powered off. Wear proper personal protective equipment during operations. Use standard disassembly tools when removing wiring terminals to avoid damaging the terminals or equipment. 154 Unless otherwise specified, the dismantling process of the equipment is in reverse order to the installation process, and it will not be further elaborated in this document. Step 1: Power off the system. Step 2: Label the cables connected in the system with tags indicating the cable type. Step 3: Disconnect the connecting cables of the inverter, battery, and smart meter in the system, such as DC cables, AC cables, communication cables, and PE cables. Step 4: Remove equipment such as the smart dongle, inverter, battery, and smart meter. Step 5: Properly store the equipment and ensure that the storage conditions meet the requirements if it needs to be put into use later. 11.3 Disposing of the Equipment If the equipment cannot work anymore, dispose of it according to the local disposal requirements for electrical equipment waste. The equipment cannot be disposed of together with household waste. 11.4 Routine Maintenance WARNING Contact after-sales service for help if you find any problems that may influence the battery or the hybrid inverter. Disassemble without permission is strictly forbidden. Contact after-sales service for help if the copper conductor is exposed. Do not touch or disassemble privately because high voltage danger exists. In case of other emergencies, contact the after-sales service as soon as possible. Operate following the instructions or wait for the after-sales service personnel. Maintaining Item Maintaining Method foreign matter or dust. Maintaining Period purpose Once half a Prevent heat year dissipation failures. Check the heat sink, air intake, and air outlet for System clean Maintaining Check whether the installation space meets 155 requirements and whether there is any debris around the device. Check whether the equipment are installed securely and whether the System screws are installed Once 6-12 installation tightly. months Check whether the Ensure that the equipment is installed securely. equipment is damaged or deformed. Electrical Connection Check whether the cables are securely connected. Confirm the Check whether the cables Once 6-12 reliability of months are broken or whether electrical connections. there is any exposed copper core. Sealing Check whether all the Confirm that the terminals and ports are machine seal and properly sealed. Reseal the Once a year waterproof cable hole if it is not sealed or performance are too big. intact. If the battery is not used for a Battery maintenance long time or is not fully charged, it is recommended to charge the battery Once/15 days Protect the battery's lifespan. regularly. 11.5 Troubleshooting Perform troubleshooting according to the following methods. Contact the after-sales service if these methods do not work. Collect the information below before contacting the after-sales service, so that the problems can be solved quickly. 1. Product information like serial number, software version, installation date, fault time, 156 fault frequency, etc. 2. Installation environment, including weather conditions, whether the PV modules are sheltered or shadowed, etc. It is recommended to provide some photos and videos to assist in analyzing the problem. 3. Utility grid situation. 11.5.1 System Troubleshooting No. Cause Solutions 1. Please ensure that no other devices are connected to the smart dongle's wireless signal. 2. Ensure that the SolarGo app has been updated to the latest version. Unable to search for 1 the wireless signal of the smart dongle. 3. Ensure that the smart dongle is powered on properly, and the blue indicator light is blinking or steady on. 4. Ensure that the smart device is within the communication range of the smart dongle. 5. Refresh the device list in the App. 6. Restart the inverter. 1. Ensure that no other devices are connected to the smart Unable to connect to 2 the wireless signal of the smart dongle. dongle's wireless signal. 2. Restart the inverter or smart dongle, and try to reconnect to the wireless signal of the smart dongle again. 3. Ensure successful pairing of Bluetooth. 1. Please ensure that the smart dongle is powered on properly, 3 Unable to find GSA-** and the blue indicator light is blinking or steady on. */GSB-***** when usin 2. Ensure that the smart device is within the communication g 4G Kit-CN-G20 or 4 range of the smart dongle. G Kit-CN-G21 module 3. Refresh the device list in the app. 4. Restart the inverter. Unable to connect GS A-***/GSB-*** when u 4 sing 4G Kit-CN-G20 or 4G Kit-CN-G21 modul e 5 1. Ensure successful pairing of Bluetooth. 2. Restart the inverter and reconnect it to the GSA-***/GSB-***. 3. Unpair with GSA-***/GSB-*** in your phone's Bluetooth setti ngs and reconnect via the app. 1. Make sure that the router is powered on. 2. When communicating via LAN, make sure that both LAN 157 The Ezlink indicator cable connection and LAN configuration are proper. Enable flashes twice. or disable DHCP based on actual needs. 3. When communicating via WiFi, make sure that the wireless network connection is OK and the wireless signal strength meets the requirements. Enable or disable DHCP based on actual needs. 1. Make sure that the smart dongle is connected to the router 6 7 via WiFi or LAN properly, and the router can access the The Ezlink indicator Internet. flashes four times. 2. If the problem persists, contact the after sales service. Indicator light blinks Please ensure that smart dongle is normally connected to the six times when using inverter. 4G Kit-CN-G20 or 4G Kit-CN-G21 module 8 Make sure that the inverter is powered on. If the problem The Ezlink indicator is persists, contact the after sales service. off. 9 The Ezlink indicator is Make sure that the inverter is powered on. off. 10 Cannot find router SSID After completing all configurations, the 11 Smart Dongle fails connecting to the router. 1. Put the router nearer to the Smart Dongle, or add a WiFi relay device to enhance the WiFi signal. 2. Reduce the number of devices connected to router. 1. Restart the inverter 2. Check if the SSID, encryption method and password on WiFi configuration page are the same with that of Router. 3. Restart the router. 4. Put the router nearer to the Smart Dongle, or add a WiFi relay device to enhance the WiFi signal. Inverter can not 12 recognize 4G Restart the router and the inverter. Kit-CN-G20 or 4G 158 11.5.2 Inverter Troubleshooting No. Fault Cause Solutions 1. Utility grid power fails. 1 Utility Loss 1. The alarm is automatically cleared after the grid power supply is restored. 2. The AC cable is disconnected, or 2. Check whether the AC cable is connected and the AC breaker is on. the AC breaker is off. 1. If the problem occurs occasionally, the utility grid may be abnormal temporarily. The inverter will recover automatically after detecting that the utility grid is normal. 2. If the problem occurs frequently, check whether the grid voltage is within the permissible range. The grid voltage Contact the local power company if the exceeds the 2 Grid permissible range, or Overvoltage the duration of high grid voltage exceeds the permissible range. Modify the overvoltage protection voltage exceeds the threshold, HVRT or disable the requirement of HVRT. overvoltage protection function after obtaining the consent of the local power company if the grid frequency is within the permissible range. 3. Check whether the AC breaker and the output cables are connected securely and correctly if the problem persists. 1. If the problem occurs occasionally, the utility grid may be abnormal temporarily. The inverter will recover automatically after 3 Grid Rapid Overvoltage The grid voltage is abnormal or detecting that the utility grid is normal. 2. If the problem occurs frequently, check whether the grid voltage is within the ultra-high. permissible range. Contact the local power company if the grid voltage exceeds the permissible range. 159 Modify the grid overvoltage rapid protection threshold after obtaining the consent of the local power company if the grid voltage is within the permissible range. 1. If the problem occurs occasionally, the utility grid may be abnormal temporarily. The inverter will recover automatically after detecting that the utility grid is normal. 2. If the problem occurs frequently, check whether the grid voltage is within the permissible range. The grid voltage is Contact the local power company if the lower than the 4 Grid permissible range, or Undervoltage the duration of low grid voltage exceeds the permissible range. Modify the undervoltage protection voltage exceeds the threshold, LVRT or disable the requirement of LVRT. undervoltage protection function after obtaining the consent of the local power company if the grid frequency is within the permissible range. 3. Check whether the AC breaker and the output cables are connected securely and correctly if the problem persists. 1. If the problem occurs occasionally, the utility grid may be abnormal temporarily. The inverter will recover automatically after detecting that the utility grid is normal. 2. If the problem occurs frequently, check 5 Grid 10min Overvoltage The moving average whether the grid voltage is within the of grid voltage in permissible range. 10min exceeds the Contact the local power company if the range of safety grid voltage exceeds the permissible requirements. range. Modify the grid overvoltage rapid protection threshold after obtaining the consent of the local power company if the grid voltage is within the permissible range. 160 1. If the problem occurs occasionally, the utility grid may be abnormal temporarily. The inverter will recover automatically after detecting that the utility grid is normal. 2. If the problem occurs frequently, check 6 Utility grid exception. whether the grid frequency is within the The actual grid permissible range. Grid frequency exceeds Contact the local power company if the Overfrequency the requirement of grid frequency exceeds the permissible the local grid range. standard. Modify the overfrequency protection threshold or disable the overfrequency protection function after obtaining the consent of the local power company if the grid frequency is within the permissible range. 1. If the problem occurs occasionally, the utility grid may be abnormal temporarily. The inverter will recover automatically after detecting that the utility grid is normal. 2. If the problem occurs frequently, check whether the grid frequency is within the Utility grid exception. Grid 7 Underfrequenc y permissible range. The actual grid Contact the local power company if the frequency is lower grid frequency exceeds the permissible than the requirement range. of the local grid Modify the underfrequency protection standard. threshold or disable the underfrequency protection function after obtaining the consent of the local power company if the grid frequency is within the permissible range, or close “Grid Underfrequency” function. Utility grid exception. 8 1. If the problem occurs occasionally, the utility The actual grid grid may be abnormal temporarily. The Grid Frequency frequency change inverter will recover automatically after Instability rate does not meet detecting that the utility grid is normal. the requirement of 2. If the problem occurs frequently, check the local grid whether the grid frequency is within the 161 standard. permissible range. Contact the local power company if the grid frequency exceeds the permissible range. Contact the dealer or the after-sales service if the grid frequency is within the permissible range. The utility grid is disconnected. The utility grid is disconnected 9 Anti-islanding 1. Check whether the utility grid is disconnected. according to the safety regulations, 2. Contact the dealer or the after-sales service. but the grid voltage is maintained due to the loads. Utility grid exception. 10 LVRT Undervoltage The duration of the 1. If the problem occurs occasionally, the utility grid may be abnormal temporarily. The utility grid exception inverter will recover automatically after exceeds the set time detecting that the utility grid is normal. of LVRT. Utility grid exception. 11 HVRT Overvoltage 2. If the problem occurs frequently, check whether the grid frequency is within the The duration of utility permissible range. If not, contact the local grid exception power company. If yes, contact the dealer or exceeds the set time the after-sales service. of HVRT. Abnormal GFCI 30mA Abnormal 12 1. If the problem occurs occasionally, it may be The input insulation caused by a cable exception. The inverter will GFCI 60mA impedance to the recover automatically after the problem is Abnormal ground decreases solved. GFCI when the inverter is 150mA working. 2. Check whether the impedance between the PV string and PE is too low if the problem occurs frequently or persists. Abnormal GFCI Large DC of 13 The DC component of AC current the output current L1 exceeds the safety Large DC of 1. range or default 162 If the problem is caused by an external fault like a utility grid exception or frequency exception, the inverter will recover automatically after solving the problem AC current without manual interference/assistance。 range. L2 2. If the problem occurs frequently and the PV station cannot work properly, contact the dealer or the after-sales service. 1. Check whether the resistance of the PV string to PE exceeds 50kΩ. If not, check the short circuit point. 2. Check whether the PE cable is connected correctly. The PV string is short-circuited to PE. 14 Low Insulation Res. The PV system is in a moist environment and the cable is not well insulated to the 3. If the resistance is lower on rainy days, please reset the ISO. Inverters for the Australian and New Zealand markets can also be alerted in the following ways in the event of insulation impedance failure: 1. The inverter is equipped with the buzzer: the buzzer sounds continuously for 1 minute in ground. case of failure; if the fault is not resolved, the buzzer sounds every 30 minutes. 2. Add the inverter to the monitoring platform, and set the alarm reminder, the alarm information can be sent to the customer by emails. 1. The PE cable of the inverter is not connected well. 2. The L cable and N Abnormal cable are Ground connected 1. Check whether the PE cable of the inverter is connected properly. 2. Check whether the L cable and N cable are connected reversely if output of the PV string reversely when is grounded. output of the PV string is grounded. 1. If the exception is caused by an external fault, Anti Reverse current 15 protection for hardwareshard the inverter will recover automatically after solving the problem. Abnormal fluctuation of load 2. If the problem occurs frequently and the PV station cannot work properly, contact the ware 16 Internal Comm dealer or the after-sales service. 1. Frame format Disconnect the AC output switch and DC input 163 Loss error 2. Parity checking error switch, then connect them 5 minutes later. Contact the dealer or the after-sales service if the problem persists. 3. Can bus offline 4. Hardware CRC error 5. Send (receive) control bit is receive (send). 6. Transmit to the unit that is not allowed. Disconnect the AC output switch and DC input 17 AC HCT Check The sampling of the switch, then connect them 5 minutes later. abnormal AC HCT is abnormal. Contact the dealer or the after-sales service if the problem persists. 18 GFCI HCT The sampling of the Check GFCI HCT is abnormal abnormal. Disconnect the AC output switch and DC input switch, then connect them 5 minutes later. Contact the dealer or the after-sales service if the problem persists. 1. Relay fault 2. The control circuit is abnormal. 19 Relay Check abnormal 3. The AC cable connection is abnormal, like a Disconnect the AC output switch and DC input switch, then connect them 5 minutes later. Contact the dealer or the after-sales service if the problem persists. virtual connection or short circuit. Disconnect the AC output switch and DC input 20 Flash Fault The internal Flash switch, then connect them 5 minutes later. storage is abnormal. Contact the dealer or the after-sales service if the problem persists. 1. The DC terminal is not firmly 21 DC Arc Fault connected. 2. The DC cable is Read the Quick Installation Guide and check whether the cables are connected properly. broken. 164 Disconnect the AC output switch and DC input 22 AFCI Self-check AFCI detection is switch, then connect them 5 minutes later. Fault abnormal. Contact the dealer or the after-sales service if the problem persists. 1. The inverter is installed in a place Cavity 23 Overtemperatu re 1. Check the ventilation and the ambient with poor temperature at the installation point. ventilation. 2. If the ventilation is poor or the ambient 2. The ambient temperature is too high, improve the temperature ventilation and heat dissipation. exceeds 60℃. 3. Contact the dealer or after-sales service if 3. A fault occurs in both the ventilation and the ambient the internal fan of temperature are normal. the inverter. 1. The PV voltage is too high. 24 BUS Overvoltage 2. The sampling of Disconnect the AC output switch and DC input switch, then connect them 5 minutes later. the inverter BUS Contact the dealer or the after-sales service if the voltage is problem persists. abnormal. The PV array 25 configuration is not Check the serial connection of the PV array. Make PV Input correct. Too many PV sure that the open circuit voltage of the PV string Overvoltage panels are connected is not higher than the maximum operating in series in the PV voltage of the inverter. string. 1. The PV 26 PV Continuous configuration is Hardware not proper. Overcurrent 2. The hardware is damaged. 1. The PV 27 PV Continuous configuration is Software not proper. Overcurrent 2. The hardware is damaged. 28 String1 PV String Disconnect the AC output switch and DC input switch, then connect them 5 minutes later. Contact the dealer or the after-sales service if the problem persists. Disconnect the AC output switch and DC input switch, then connect them 5 minutes later. Contact the dealer or the after-sales service if the problem persists. The PV string is Check whether the PV1 and PV2 strings are connected reversely. connected reversely. 165 Reversed String2 PV String Reversed 1. Generator is not connected. 2. The generator is Generator 29 waveform detection fault faulty. 3. The parameter generator the requirements requirements, but the fault still exists after of the restarting the generator, please contact your specification. dealer or after-sales service center. faulty. 3. The parameter abnormal generator has any fault and whether the parameter settings meet the requirements. If parameter settings do not exceed the the requirements requirements, but the fault still exists after of the restarting the generator, please contact your specification. dealer or after-sales service center. faulty. 3. The voltage setting of the generator exceeds of the specification. 1. Generator is not Generator connected. frequency 2. The generator is abnormal stop the generator operation. Check if the generator exceed the requirements 32 fault. If the generator is connected, immediately there is no fault with the generator and the 2. The generator is voltage If the generator is not connected, ignore the settings of the connected. 31 parameter settings meet the requirements. If parameter settings do not exceed the 1. Generator is not Generator generator has any fault and whether the generator exceed 2. The generator is connection of stop the generator operation. Check if the there is no fault with the generator and the connected. 30 fault. If the generator is connected, immediately settings of the 1. Generator is not Abnormal If the generator is not connected, ignore the faulty. 3. The frequency If the generator is not connected, ignore the fault. If the generator is connected, immediately stop the generator operation. Check if the generator has any fault and if the voltage setting meets the requirements. If the generator is in good condition and the voltage setting is not lower than the requirements, but the fault still exists after restarting the generator, please contact your dealer or after-sales service center. If the generator is not connected, ignore the fault. If the generator is connected, immediately stop the generator operation. Check if the generator has any fault and if the voltage setting meets the requirements. If the generator is in 166 setting of the good condition and the frequency setting does generator exceeds not exceed the requirements, but the fault still the requirements exists after restarting the generator, please of the contact your dealer or after-sales service center. specification. 1. When a generator is connected to the port, immediately stop the operation of the 1. The load generator, check whether the line is properly connected to the connected, and confirm whether the generator is too parameters such as output voltage, current, large, and the and power on the back-up side exceed the current or power parameter requirements of the specification. of the GEN port If the cable is not properly connected, check exceeds the and reconnect it. If the parameters exceed requirements the requirements of the specifications, reset specified in the the parameters according to the specification. requirements. If the circuit is intact and the 2. The short circuit parameter settings are within the specified on the back-up 33 GEN port side leads to the overload current of the generator port exceeding the range, but the problem persists, please contact your dealer or after-sales service center. 2. When the port is connected to a heavy load, turn off the heavy load, check if the line is requirements properly connected, and confirm if the load specified in the exceeds the requirements of the specifications. specification. If the cable is not properly 3. When used as a connected, check and reconnect it. If the high-load port, cable is not properly connected, check and the high load reconnect it. If the load exceeds the exceeds the requirements in the specification, reduce the requirements load. If the cables are well connected and the specified in the load does not exceed the specifications, but specifications. the fault still exists, please contact your dealer or after-sales service center. 34 Communicatio 1. Check whether the WiFi signal is normal. If it n indicator of is not, check whether the router works well. the inverter Ezlink connection and Ezlink failed 2. Check whether Ezlink obtains IP successfully via APP. Execute the following actions if IP is indicator in error not obtained: 3. Reset the communication parameters via APP. 167 4. Check whether the server connection is correct. 5. Log in to the website mqtt.goodwe-power.com via a computer to view the resolved IP address and obtain the server connection information. 1. Incorrect communication cable connection or unreliable cable connection cause communication failure. 2. Connect the smart meter and Ezlink module to the same master inverter to ensure the Unable to log in to the 35 parallel system interface in Parallel networking failed success rate of networking. 3. Check whether the inverter communication indicator is normal. If not, please check the APP individual inverter according to its own troubleshooting method. 4. If the above methods cannot solve the problem, please try to restart the inverter and get networking again. 1. Check whether the parallel communication 36 Parallel IO check fail Communication of parallel inverters in cable is connected correctly and firmly. 2. If the communication cable connection is normal, it may be an internal communication error failure. Please contact the dealer or After Sale Service. 37 Parallel Grid AC L and N cables are line reversed connected reversely. 1. Check the grid wiring. Reconnect the ON-GRID AC cable to make sure the grid is wired correctly. 1. Check the BMS communication cable connection, and make sure it is reliable. Battery 38 indicator Check whether the battery type is matched Battery failure via APP. If you can't solve it, please refer to abnormal the user manual of the corresponding battery for troubleshooting. 1. Check whether the quantity of parallel 39 Device offline Communication machines in the system is the same with that displayed on failure or equipment of the actual connected ones. APP failure 2. If yes, get the SN of the corresponding offline inverter from the equipment list, and 168 troubleshoot the corresponding inverter according to its user manual. 3. Check whether the communication connection of the equipment is normal, with no loose, aging or wrong connection, etc. 11.5.3 Battery Fault (LX A5.0-30, LX U5.0-30) Alarm state When the battery ALM indicator turns red, troubleshoot the issue by referring to the SOC indicator's display status. No. SOC indicator Fault Solutions 1. Check whether the Charging Current Limit of the inverter is 0 through SolarGo. If yes, 1 Battery please confirm whether the communication overvoltage cable connection between the battery and protection the inverter is reliable and the Battery communication is normal. undervoltage protection 2. Power off and wait for 5 minutes, then restart to confirm if the fault persists. 3. If the fault is not restored, contact the after-sales service. 1. Check if the battery model is correct through SolarGo and confirm if the real-time current of the battery is greater than the Charging/Discharging Current Limit. Please contact the after-sales service. 2 protection 2. When it is less than the Charging/Discharging Current Limit., turn off the battery or upgrade the program, restart to confirm whether the fault persists. 3. If the fault is not restored, contact the after-sales service. 169 Over temperature protection 3 Low temperature Power off and wait for 60 minutes, wait for the protection temperature to recover. If the problem persists Pole over after restarting, contact the after-sales service. temperature protection Balancing fault 4 Low SOH fault Power off and wait for 30 minutes. If the problem persists after restarting, contact the after-sales service. 1. Confirm if the battery output terminal is 5 Pre charge failure fault connected in reverse to the inverter 2. Power off and wait for 30 minutes. If the problem persists after restarting, contact the after-sales service. 6 Wire harness exception Relay or MOS over temperature Diverter over temperature 7 Confirm if the battery switch is closed. If the battery switch is closed and the problem persists. Contact the after-sales service. Power off and wait for 30 minutes. If the problem persists after restarting, contact the after-sales service. 1. Check if the battery power cable is connected Other BMS faults: output port over temperature fault tightly. 2. Power off and wait for 5 minutes. If the problem persists after restarting, contact the after-sales service. Other protections: 8 9 10 MOS cannot be Power off and wait for 5 minutes. If the problem closed persists after restarting, contact the after-sales Other protections: service. MOS adhesion Other protections: 1. Confirm whether the type and installation Cluster Fault position of the terminal resistor used are 170 correct. 2. Confirm whether the communication cable between batteries, the cable between batteries and inverters are reliable and the communication is normal. 3. If the problem persists, contact the after-sales service. 1. Confirm whether the communication cable Other protections: 11 Communication loss with inverter between batteries, the cable between batteries and inverters are reliable and the communication is normal. 2. If the problem persists, contact the after-sales service. 1. Confirm whether the type and installation position of the terminal resistor used are correct. Other protections: 2. Confirm whether the communication cable 12 BMU between batteries, the cable between communication batteries and inverters are reliable and the failure communication is normal. 3. Power off and wait for 5 minutes. If the problem persists after restarting, contact the after-sales service. Other protections: Power off and wait for 5 minutes. If the problem 13 14 Air switch persists after restarting, contact the after-sales adhesion fault service. Other protections: software fault Other protections: 15 hardware Restart the battery. If the problem persists after overcurrent fault restarting, contact the after-sales service. Other protections: 16 Microelectronics fault Heating film 1. Upgrade software. 171 abnormal 2. Power off and wait for 5 minutes. If the problem persists after restarting, contact the after-sales service. 11.5.4 Battery Fault(LX A5.0-10) When the battery ALM indicator turns red, troubleshoot the issue by referring to the SOC indicator's display status. No. 1 2 3 SOC indicator Fault Solutions Battery Power off and wait for 2 hours. If the problem Overvoltage persists, contact after-sales service Battery Undervoltage Contact the after-sales service. High Cell Power off and wait for 2 hours. If the problem Temperature persists, contact after-sales service. Turn off the device to wait for the 4 Low Charging temperature to recovers. If the problem Temperature persists after restarting,contact the after-sales service.. Turn off the device to wait for the 5 Low Discharging temperature to return to normal. If the Temperature problem persists after restarting, contact the after-sales service.. 6 7 8 Overcurrent Restart the battery. If the problem persists, Charging contact after-sales service. Overcurrent Restart the battery. If the problem persists, Discharging contact after-sales service. Low Insulation Resistance Excessive 9 temperature difference Contact the after-sales service. Power off and wait for 2 hours. If the problem persists, contact after-sales service 172 10 11 12 Voltage Leave the battery alone for 12h after Difference restarting. If the problem persists, contact Exception the after-sales service. Inconsistency of battery cells Wire harness Restart the battery. If the problem persists, exception contact after-sales service. MOS 13 Open-Circuit Fault MOS 14 Open-Circuit Fault 15 Contact the after-sales service. Cluster Fault Restart the battery. If the problem persists, contact after-sales service. Restart the battery. If the problem persists, contact after-sales service. Please check if the battery model matches. If not, contact the after-sales service . Check whether the termination resistor is 16 Interlock failure installed properly and restart the battery. Contact the after-sale service if the problem persists. BMU 17 communication fault MCU 18 Communication Fault 19 20 Open contact sticking fault Restart the battery. If the problem persists, contact after-sales service Contact the after-sales service. Restart the battery. If the problem persists, Failure contact after-sales service over-temperatur e fault 22 contact after-sales service Pre-charge MOS 21 Restart the battery. If the problem persists, Current Diverter Over Power off and wait for 2 hours. If the problem persists, contact after-sales service Power off and wait for 2 hours. If the problem 173 temperature persists, contact after-sales service Reverse Connection 23 Contact the after-sales service. Fault Microelectronic 24 Fault Contact the after-sales service. 11.5.5 Battery Fault (LX U5.4-L) Alarm state When the battery button indicator light displays green, combine with the SOC indicator light to locate and troubleshoot the alarm. SOC Indicator Fault Solutions Temperature Exception Power off and restart after 2 hours. If the High problem persists, contact after-sales service. Temperature Low Power off and wait for the temperature to Temperature increase. Restart the battery. If the problem Discharging persists, contact after-sales service. Overcurrent When Charging Overcurrent When Restart the battery. If the problem persists, contact after-sales service. Discharging Overvoltage Press the button consecutively for 5 times in Under voltage 10s if you can charge the battery. The voltage will recover to normal. 174 Low Power off and wait for the temperature to Temperature increase. Restart the battery. If the problem Charging persists, contact after-sales service. The cell voltage Power off and restart after 2 hours. If the difference is problem persists, contact after-sales service. extremely high Fault state When the battery button indicator light displays red and flashes for 3 seconds, locate and troubleshoot the fault based on the SOC indicator light display status. SOC Indicator Fault Temp. sensor failure MOS Failure Solutions Restart the battery. If the problem persists, contact after-sales service for help. Circuit-Breaker Connect the Circuit-Breaker. If the problem Failure persists, contact after-sales service. Slaver Control Power off and check the communication cable. Communication Restart the battery. If the problem persists, Lost contact after-sales service. SN Failure Contact after-sales service for help. Master Control Power off and check the communication cable. Communication Restart the battery. If the problem persists, Lost contact after-sales service. Inconsistent Software Version Contact after-sales service for help. Multi Master Control Start all batteries in 30s after shutting down. Failure 175 MOS Power off for 2 hours. If the problem persists, Overtemperature contact after-sales service. Communication Failure Power off and check the communication cable. Restart the battery. If the problem persists, contact after-sales service. 11.5.6 Battery Fault (LX U5.4-20) Alarm state When the battery button indicator light displays red and flashes 1time/s, combine with the SOC indicator light to locate and troubleshoot the alarm. No. SOC indicator Description 1 2 The alerting is dealt by the battery system itself. For more detailed information, you can check via 3 SolarGo App 4 5 6 Fault Status When the battery button indicator light is in steady red, locate and troubleshoot the fault based on the SOC indicator light display status. Button SOC indicator indicator Fault Steady red Overvoltage Red light Under voltage Solutions Power off for 2 hours. If the problem persists, contact after-sales service. Contact after-sales service. 176 blink 1 time/s Cell High Power off for 2 hours. If the problem Temperature persists, contact after-sales service. Low Temperature Power off the equipment and wait until the Charging temperature recovers. If the problem Low Temperature persists after restarting, contact after-sales Discharging service. Charging Overcurrent Restart the battery. If the problem persists, Discharging contact after-sales service. Overcurrent Temperature Power off for 2 hours. If the problem Exception persists, contact after-sales service. The cell voltage difference is extremely high Steady red Power off for 12 hours. If the problem persists, contact after-sales service. Harness Abnormal MOS Open-Circuit Restart the battery. If the problem persists, Fault contact after-sales service. MOS Short-Circuit Fault Parallelized Connection Fault Check the battery model. If the battery model is not correct, contact after-sales service. BMU Communication Fault Restart the battery. If the problem persists, contact after-sales service. MCU Internal communication 177 fault Air Switch Short Circuit Fault Contact after-sales service for help. Pre-charge Restart the battery. If the problem persists, Failure contact after-sales service for help. MOS Over Power off for 2 hours. If the problem temperature persists, contact after-sales service. Fault Current Sensor Over Power off for 2 hours. If the problem temperature persists, contact after-sales service. Fault Microelectronic Fault Contact after-sales service for help. 12 Parameters 12.1 Inverter Parameters Technical GW3000 GW360 GW3600 GW5000-E GW5000 GW6000- GW6000M Parameters -ES-20 0-ES-20 M-ES-20 S-20 M-ES-20 ES-20 -ES-20 Battery Input Data Battery Type*1 Li-Ion/Le ad-acid Li-Ion/L ead-aci Li-Ion Li-Ion/Lea d-acid d Li-Ion Li-Ion/Lea d-acid Li-Ion Nominal Battery 48 48 48 48 48 48 48 40~60 40~60 40~60 40~60 40~60 40~60 40~60 60 75 60 120 60 120 60 Voltage (V) Battery Voltage Range (V) Max. 178 Continuous Charging Current (A)*1 Max. Continuous Discharging 60 75 60 120 60 120 60 3,000 3,600 3,000 5,000 3,000 6,000 3,000 3,200 3,900 3,200 5,300 3,200 6,300 3,200 4,500 5,400 5,400 7,500 7,500 9,000 9,000 600 600 600 600 600 600 600 60~550 60~550 60~550 60~550 60~550 60~550 60~550 150~500 200~500 200~500 220~500 200~500 Current (A)*1 Max. Charge Power (W)*1 Max. Discharge Power (W) PV Input Data Max. Input Power (W)*2 Max. Input Voltage (V) MPPT Operating Voltage Range (V) MPPT Voltage Range at Nominal 220~500 150~50 0 Power (V) Start-up Voltage (V) 58 58 58 58 58 58 58 360 360 360 360 360 360 360 16 16 16 16 16 16 16 23 23 23 23 23 23 23 Nominal Input Voltage (V) Max. Input Current per MPPT (A) Max. Short Circuit Current per MPPT (A) 179 Max. Backfeed Current to 0 0 0 0 0 0 0 1 2 2 2 2 2 2 1 1 1 1 1 1 1 3,000 3,680 3,680 5,000*3 5,000*3 6,000*3 6,000*3 3,000 3,680 3,680 5,000*3 5,000*3 6,000*3 6,000*3 3,000 3,680 3,680 5,000 5,000 6,000 6,000 6,000 7,360 3,680 10,000 5,000 10,000 6,000 220/230/ 220/23 220/230/ 220/230/2 220/230/2 220/230/ 220/230/2 240 0/240 240 40 40 240 40 170~280 170~280 170~280 170~280 170~280 50/60 50/60 50/60 50/60 50/60 The Array (A) Number of MPP Trackers Number of Strings per MPPT AC Output Data (On-grid) Nominal Apparent Power Output to Utility Grid (VA) Max. Apparent Power Output to Utility Grid (VA) Nominal Apparent Power from Utility Grid (VA) Max. Apparent Power from Utility Grid (VA) Nominal Output Voltage (V) Output Voltage 170~280 Range (V) Nominal AC Grid 50/60 170~28 0 50/60 180 Frequency (Hz) AC Grid Frequency Range (Hz) 45~55 / 45~55 / 45~55 / 45~55 / 45~55 / 45~55 / 45~55 / 55~65 55~65 55~65 55~65 55~65 55~65 55~65 13.6 16.7 16.7 22.7 22.7 27.3 27.3 27.3 33.5 16.7 43.5 22.7 43.5 27.3 13.0 16.0 16.0 21.7 21.7 26.1 26.1 96A@3 96A@3μ μs s 96A@3μs 96A@3μs 96A@3μs 96A@3μs 96A@3 96A@3μ μs s 96A@3μs 96A@3μs 96A@3μs 96A@3μs 16.0 16.0 21.7 21.7 26.1 26.1 ~1 ~1 ~1 ~1 (Adjustabl (Adjustabl (Adjustabl (Adjustable e from 0.8 e from 0.8 e from 0.8 from 0.8 leading to leading to leading to leading to 0.8 0.8 0.8 0.8 lagging) lagging) lagging) lagging) Max. AC Current Output to Utility Grid (A) Max. AC Current From Utility Grid (A) Nominal AC Current From Utility Grid (A) Max. Output Fault Current (Peak and 96A@3μs Duration) (A) Inrush Current (Peak and Duration) 96A@3μs (A) Nominal Output 13.0 Current (A) ~1 Power Factor ~1 (Adjust ~1 (Adjustab able (Adjusta le from from ble from 0.8 0.8 0.8 leading leading leading to 0.8 to 0.8 to 0.8 lagging) lagging lagging) ) 181 Max. Total Harmonic <3% <3% <3% <3% <3% <3% <3% 60 60 60 80 60 80 60 a.c. a.c. a.c. a.c. a.c. a.c. a.c. 3,680 3,680 5,000 5,000 6,000 6,000 Distortion Maximum Output Overcurrent Protection (A) Type of Voltage (a.c. or d.c.) AC Output Data (Back-up) Back-up Nominal Apparent 3,000 Power (VA) Max. Output 3,000(6,0 Apparent 00@10se Power (VA) c) 3,680(7, 360@1 0sec) 5,000(10,0 3,680 00@10sec) 6,000(10, 5,000 000@10s 6,000 ec) Nominal Output 13.0 16.0 16.0 21.7 21.7 26.1 26.1 13.6 16.7 16.7 22.7 22.7 27.3 27.3 96A@3 96A@3μ μs s 96A@3μs 96A@3μs 96A@3μs 96A@3μs 96A@3 96A@3μ μs s 96A@3μs 96A@3μs 96A@3μs 96A@3μs 60 60 60 80 60 80 60 220/230/ 220/23 220/230/ 220/230/2 220/230/2 220/230/ 220/230/2 Current (A) Max. Output Current (A) Max. Output Fault Current (Peak and 96A@3μs Duration) (A) Inrush Current (Peak and Duration) 96A@3μs (A) Maximum Output Overcurrent Protection (A) Nominal 182 Output 240 0/240 240 40 40 240 40 50/60 50/60 50/60 50/60 50/60 50/60 50/60 <3% <3% <3% <3% <3% <3% <3% 97.6% 97.6% 97.6% 97.6% 97.6% 97.6% 97.6% 96.7% 96.7% 96.7% 96.7% 96.7% 96.7% 96.7% 96.9% 96.9% 96.9% 96.9% 96.9% 96.9% 96.9% 95.5% 95.5% 95.5% 95.5% 95.5% 95.5% 95.5% 99.9% 99.9% 99.9% 99.9% 99.9% 99.9% 99.9% Integrate Integrat Integrate Integrate Integrate d ed d d d Integrate Integrat Integrate Integrate Integrate d ed d d d Integrate Integrat Integrate Integrate Integrate d ed d d d Integrate Integrat Integrate Integrate Integrate d ed d d d Anti-islandin Integrate Integrat Integrate Integrate Integrate g Protection d ed d d d Integrate Integrat Integrate Integrate Integrate Voltage (V) Nominal Output Frequency (Hz) Output THDv (@Linear Load) Efficiency Max. Efficiency European Efficiency CEC Efficiency Max. Battery to AC Efficiency MPPT Efficiency Protection PV String Current Monitoring PV Insulation Resistance Detection Residual Current Monitoring PV Reverse Polarity Protection AC Integrated Integrated Integrated Integrated Integrated Integrated 183 Integrated Integrated Integrated Integrated Integrated Integrated Overcurrent d ed d d d Integrate Integrat Integrate Integrate Integrate d ed d d d Integrate Integrat Integrate Integrate Integrate d ed d d d Integrate Integrat Integrate Integrate Integrate d ed d d d Type II Type II Type II Type II Type II Type II Type II Type III Type III Type III Type III Type III Type III Type III Optional Optional Optional Optional Optional Integrate Integrate d d Protection AC Short Circuit Protection AC Overvoltage Protection DC Switch DC Surge Protection AC Surge Protection Optiona AFCI Optional Remote Integrate Integrat Integrate Shutdown d ed d l Integrated Integrated Integrated Integrated Integrated Integrated Integrated Integrated General Data Operating Temperature -25~+60 Range (℃) Relative Humidity 0~95% Max. 3000 Operating (>2000 Altitude (m) derating) Cooling Method User Interface Communicati on with BMS -25~+6 0 0~95% 3000 (>2000 deratin g) -25~+60 -25~+60 -25~+60 -25~+60 -25~+60 0~95% 0~95% 0~95% 0~95% 0~95% 3000 3000 3000 3000 3000 (>2000 (>2000 (>2000 (>2000 (>2000 derating) derating) derating) derating) derating) Natural Natural Natural Natural Natural Natural Convecti Convect Convecti Convectio Convectio Convectio on ion on n n n LED, LED, LED, LED, LED, LED, LED, WLAN+A WLAN+ WLAN+ WLAN+AP WLAN+A WLAN+A WLAN+AP PP APP APP P PP PP P CAN CAN CAN CAN CAN CAN CAN 184 Natural Convection Communicati RS485 RS485 RS485 WiFi / WiFi / WiFi / Communicati WiFi WiFi WiFi on with Portal +LAN / +LAN / +LAN / 4G 4G 4G 19.6 20.8 20.0 505.9× 505.9× 434.9× on with Meter Weight (kg) Dimension ( W×H×D mm) Noise Emission (dB) Topology RS485 RS485 RS485 RS485 WiFi / WiFi / WiFi / WiFi WiFi WiFi WiFi / WiFi +LAN / 4G +LAN / +LAN / +LAN / 4G 4G 4G 21.5 20.0 21.5 20.0 505.9× 505.9× 505.9× 505.9× 505.9× 434.9× 434.9× 434.9× 434.9× 434.9× 434.9× 154.8 154.8 154.8 154.8 154.8 154.8 154.8 <30 <30 <30 <30 <30 <30 <30 Non-isol Non-iso Non-isol Non-isolat Non-isola Non-isola Non-isolat ated lated ated ed ted ted ed <10 <10 <10 <10 <10 <10 <10 IP65 IP65 IP65 IP65 IP65 IP65 IP65 Self-consump tion at Night (W) Ingress Protection Rating MC4, DC Connector MC4, VACON MC4, MC4, MC4, MC4, MC4, VACONN N VACONN VACONN VACONN VACONN VACONN Terminal Termina Terminal Terminal Terminal Terminal Terminal l VACON AC Connector VACONN N VACONN VACONN VACONN VACONN VACONN Terminal Termina Terminal Terminal Terminal Terminal Terminal l Environmenta 4K4H 4K4H 4K4H 4K4H 4K4H 4K4H 4K4H III III III III III III III DC II / AC DC II / DC II / DC II / AC DC II / AC DC II / AC DC II / AC Category III AC III AC III III III III III Protective I I I I I I I l Category Pollution Degree Overvoltage 185 Class Storage Temperature -40~+85 (℃) -40~+8 5 -40~+85 -40~+85 -40~+85 -40~+85 -40~+85 Battery: A Battery: A Battery: A Battery: A PV: C PV: C PV: C PV: C AC: C AC: C AC: C AC: C Com: A Com: A Com: A Com: A Wall Wall Wall Wall Wall Mounted Mounted Mounted Mounted Mounted SMS(Slip SMS(Slip- SMS(Slip- SMS(Slip- SMS(Slip- -mode mode mode mode mode frequenc frequency) frequency frequency frequency) y) +AFD +AFD ) +AFD ) +AFD +AFD Battery: Battery: Battery: The Decisive A A A Voltage Class PV: C PV: C PV: C (DVC) AC: C AC: C AC: C Com: A Com: A Com: A Mounting Wall Method Mounted Active Anti-islandin g Method SMS(Slip -mode frequenc y) +AFD Wall Mounte d SMS(Sli p-mode frequen cy) +AFD Type of Electrical single single single single single single single Supply phase phase phase phase phase phase phase China China China China China China China System Country of Manufacture Certification *4 Grid Standards AS4777.2-2020;NRS 097-2-1;CEI 0-21 Safety IEC62109-1&2 Regulation EMC IEC 61000-6-1/2/3/4; IEC61000-4-16/18/29; IEC 61000-2-2,CISPR 11; EN300328; EN301489; EN IEC 62311 *1: The actual charge and discharge current/power also depends on the battery. *2: The max power is the actual power of PV. Besides, in Australia, for most of the PV module, the max. input power can achieve 2*Pn, such as the max. input power of GW3000-ES-20 can achieve 6000W. *3: 4600 for VDE-AR-N4105 & NRS 097-2-1. *4: Not all certifications & standards listed, check the official website for details. 186 Technical Data GW6000-ES-BR20 GW3500L-ES-BR20 GW3600-ES-BR20 Li-Ion/Lead-acid Li-Ion/Lead-acid Li-Ion/Lead-acid 48 48 48 40~60 40~60 40~60 Start-up Voltage (V) 40 40 40 Number of Battery Input 1 1 1 120 75 75 120 75 75 6000 3500 3600 6300 3800 3900 Max. Input Power (W) *2 10,800 6,300 6,480 Max. Input Voltage (V) 600 600 600 60~550 60~550 60~550 220~500 150~500 150~500 58 58 58 360 360 360 16 16 16 23 23 23 0 0 0 2 2 2 Battery Input Data Battery Type*1 Nominal Battery Voltage (V) Battery Voltage Range (V) Max. Continuous Charging Current (A) Max. Continuous Discharging Current (A) Max. Charge Power (W) Max. Discharge Power (W) PV String Input Data MPPT Operating Voltage Range (V) MPPT Voltage Range at Nominal Power (V) Start-up Voltage (V) Nominal Input Voltage (V) Max. Input Current per MPPT (A) Max. Short Circuit Current per MPPT (A) Max. Backfeed Current to The Array (A) Number of MPP Trackers 187 Number of Strings per MPPT 1 1 1 6000 3500 3680 6000 3500 3680 6000 3500 3680 6000 3500 3680 6000 3500 3680 6000 3500 3680 6000 3500 3680 10,000 5500 7360 220 127 220 165~280 95~165 165~280 60 60 60 45~55 / 55~65 55~65 45~55 / 55~65 27.3 27.6 16.7 43.5 43.5 33.5 96A@3μs 96A@3μs 96A@3μs AC Output Data (On-grid) Nominal Output Power (W) Max. Output Power (W) Nominal Apparent Power Output to Utility Grid (VA) Max. Apparent Power Output to Utility Grid (VA) Nominal Power at 40℃ (W)*3 Max. Power at 40℃ (Including AC Overload) (W)*3 Nominal Apparent Power from Utility Grid (VA) Max. Apparent Power from Utility Grid (VA) Nominal Output Voltage (V) Output Voltage Range (V) Nominal AC Grid Frequency (Hz) AC Grid Frequency Range (Hz) Max. AC Current Output to Utility Grid (A) Max. AC Current From Utility Grid (A) Max. Output Fault Current (Peak and 188 Duration) (A) Inrush Current (Peak and Duration) (A) Nominal Output Current (A) Power Factor Max. Total Harmonic Distortion 96A@3μs 96A@3μs 96A@2μs 27.3 27.6 16.7 ~1 (Adjustable from ~1 (Adjustable from 0.8 leading to 0.8 0.8 leading to 0.8 lagging) lagging) <3% <3% <3% 80 80 80 6000 3500 3680 6000(10000@10s) 3500(5800@10s) 3680(7360@10s) 6000 3500 3680 27.3 27.6 16.7 27.3 27.6 16.7 96A@3μs 96A@3μs 96A@3μs 96A@3μs 96A@3μs 96A@3μs 80 80 80 220 127 220 60 60 60 ~1 (Adjustable from 0.8 leading to 0.8 lagging) Maximum Output Overcurrent Protection (A) AC Output Data (Back-up) Back-up Nominal Apparent Power (VA) Max. Output Apparent Power without Grid (VA) Max. Output Apparent Power with Grid (VA) Nominal Output Current (A) Max. Output Current (A) Max. Output Fault Current (Peak and Duration) (A) Inrush Current (Peak and Duration) (A) Maximum Output Overcurrent Protection (A) Nominal Output Voltage (V) Nominal Output Frequency (Hz) 189 Output THDv (@Linear <3% <3% <3% <10ms <10ms <10ms <10ms <10ms <10ms Max. Efficiency 97.60% 96.0% 97.60% European Efficiency 96.70% 95.60% 96.70% 95.70% 94.00% 95.50% 99.90% 99.90% 99.90% Integrated Integrated Integrated Integrated Integrated Integrated Integrated Integrated Integrated Integrated Integrated Integrated Integrated Integrated Integrated Integrated Integrated Integrated Integrated Integrated Integrated Integrated Integrated Integrated Integrated Integrated Integrated DC Surge Protection Type II Type II Type II AC Surge Protection Type III Type III Type III AFCI Optional Optional Optional Load) Switching from Grid Connected Mode to Standalone Mode Switching from standalone mode to network connected mode Efficiency Max. Battery to AC Efficiency MPPT Efficiency Protection PV String Current Monitoring PV Insulation Resistance Detection Residual Current Monitoring PV Reverse Polarity Protection Anti-islanding Protection AC Overcurrent Protection AC Short Circuit Protection AC Overvoltage Protection DC Switch 190 Remote Shutdown Integrated Integrated Integrated -25~+60 -25~+60 -25~+60 3000 (>2000 3000 (>2000 derating) derating) Cooling Method Natural Convection Natural Convection Natural Convection User Interface LED, WLAN+APP LED, WLAN+APP LED, WLAN+APP CAN CAN CAN RS485 RS485 RS485 WiFi / WiFi +LAN / WiFi / WiFi +LAN / Portal 4G 4G Weight (kg) 21.5 21.5 20.8 505.9×434.9×154.8 505.9×434.9×154.8 505.9×434.9×154.8 <30 <30 <30 Non-isolated Non-isolated Non-isolated <10 <10 <10 IP65 IP65 IP65 MC4, VACONN MC4, VACONN Terminal Terminal AC Connector VACONN Terminal VACONN Terminal VACONN Terminal Protective class I I I 4K4H 4K4H 4K4H III III III DC II / AC III DC II / AC III DC II / AC III -40~+85 -40~+85 -40~+85 Battery:A Battery:A Battery:A PV:C PV:C PV:C AC:C AC:C AC:C General Data Operating Temperature Range (℃) Max. Operating Altitude (m) Communication with BMS Communication with Meter Communication with Dimension (W×H×D mm) Noise Emission (dB) Topology Self-consumption at Night (W) Ingress Protection Rating DC Connector Environmental Category Pollution Degree Overvoltage Category Storage Temperature (℃) The Decisive Voltage Class (DVC) 191 3000 (>2000 derating) WiFi / WiFi +LAN / 4G MC4, VACONN Terminal Com:A Com:A Com:A Mounting Method Wall Mounted Wall Mounted Wall Mounted Active Anti-islanding SMS(Slip-mode SMS(Slip-mode SMS(Slip-mode frequency) Method frequency) +AFD frequency) +AFD +AFD single phase single phase single phase China China China Type of Electrical Supply System Country of Manufacture Certification*4 Grid Standards N140 Safety Regulation IEC62109-1&2 EMC IEC 61000-6-1/2/3/4; IEC61000-4-16/18/29; IEC 61000-2-2,CISPR 11; EN300328; EN301489; EN IEC 62311 *1: The actual charge and discharge current/power also depends on the battery. *2: For most of the PV module, the max. Input power can achieve 2Pn, Such as the max. input power o f GW6000-ES-BR20 can achieve 12000W *3 The nominal Power at 40℃ and Max. Power at 40℃ are only for Brazil. *4: Not all certifications & standards listed, check the official website for details. 12.2 Battery Parameters LX A5.0-30 Technical Parameters LX A5.0-30 Nominal Capacity (kWh) 5.12 Usable energy (kWh) * 1 5 Cell Type LFP (LiFePO4) Operating Voltage Range (V) 43.2~58.24 Nominal Charge Current (A) *3 60 Max. Continuous Charge Current (A) *2*3 90 Nominal Discharge Current (A) *3 100 Max. Continuous Discharge Current (A) *2*3 150 192 Max. Pulse Discharge Current (A) 200A(30s) Max. Continuous Discharge Power (W) 7200 Communication CAN Operating Temperature Range (℃) Charge: 0<T≤55℃; Discharge: -20<T≤55℃ Max. Storage Time 12 Months (maintenance-free) Maximum Operating Altitude (m) 4000 Weight (Kg) 44 Dimensions (W x H x D mm) 442*133*520 (core part), 483*133*559 (max. dimensions) Ingress Protection Rating IP20 Application Method On-grid/On-grid + Back-up/Back-up Supports up to 30 in parallel connection(150kWh) Scalability (Hand-in-hand/Busbar connection) Mounting Method 19-inch standard rack/floormounted, wall-mounted Cycle Efficiency*1 ≥96% Cycle Life 6000(25℃±2℃,0.2C,70%EOL) Warranty*4 10 years Safety Standard and Certification EMC IEC62619、IEC63056、N140 EN IEC61000-6-1、EN IEC61000-6-2、EN IEC61000-6-3、 EN IEC61000-6-4 Transportation UN38.3、ADR Environment ROHS、REACH *1: Test conditions: 100% DOD, 0.2C charge & discharge at 25°C± 2 ℃,at the beginning of life. *2: Max. charge / discharge current may be variant with different inverter models *3: Recommend/Max. Charging/Discharging Current/ Nominal/Max. Power* derating will occur related to temperature and SOC. *4: The warranty is due whichever reached first of warranty period or energy throughput. LX U5.0-30 193 Technical Parameters LXU 5.0-30 Nominal Battery Energy (kWh) 5.12 Usable Energy (kWh)*1 5 Cell Type LiFePO4 Nominal Voltage (V) 51.2 Operating Voltage Range (V) 43.2~58.24 Nominal Charge Current (A) 60 Max Charge Current (A)*2*3 90 Nominal Discharge Current (A) 100 Max Discharge Current (A)*2*3 100 Pulse Discharging current (A)*2*3 <200A(30S) Max. Charging/Discharging Power (kW) 4.95 Communication CAN TChg (Charging Temperature Range) (℃) 0<T≤55 TDsch (Discharging Temperature Range) (℃) Ambient Temperature(℃) -20<T≤55 0<T≤40(Recommend 10<T≤30) Optional heating:-20<T≤40(Recommend 10<T≤30) Relative Humidity 5~95% Maximum Storage Time 12 Months(maintenance-free) Max. Operating Altitude (m) 4000 Heating Optional Fire Suppression Optional, Aerosol Unit Weight (kg) 50 Unit Dimensions(W*H*D mm) 460*580*160 Enclosure Protection Rating IP65 Applications On Grid / On Grid + Backup / off Grid Scalability 30P Wall Mounted / Grounded Mounting Method 194 Round-trip Efficiency*1 ≥96% Cycle Life Safety >6000 @25±2℃ 0.5C 70%SOH 90%DOD VDE2510-50、IEC62619、IEC62040、N140、IEC63056 EN IEC61000-6-1, EN IEC61000-6-2, EN IEC61000-6-3, EMC EN IEC61000-6-4 Transportation UN38.3、ADR Environment ROHS *1 Test conditions: 100% DOD, 0.2C charge & discharge at 25°C±2℃,at the beginning of life. *2 The system's working current and power values will be related to temperature and State of Charge (SOC). *3 Max charge / discharge current values may be variant with different inverter models. LX A5.0-10 Technical Parameters LX A5.0-10 2*LX A5.0-10 n*LX A5.0-10 usable energy (kWh) * 1 5 10 n×5 Battery Module LX A5.0-10:51.2V 5.0kWh Number of Modules 1 Cell Type LFP(LiFePO4) Nominal Voltage (V) 51.2 Operating Voltage Range (V) 47.5~57.6 Nominal Charge/Discharge Current (A) *2 Nominal Charge/Discharge Power (kW) *2 2 n 60 120 n×60*3 3 6 n×3*3 Operating Temperature Range (℃) Charge: 0 ~ +50; Discharge: -10 ~ +50 Relative Humidity 0~95% Max. Operating Altitude (m) 3000 Communication CAN Weight (Kg) 40 Dimensions (W x H x D mm) 80 n×40 Single LX A5.0-10 module: 442×133×420 (without handle); 483×133×452 (with handle) 195 Ingress Protection Rating IP21 0 ~ +35 (≤ 1 year); -20 ~ 0 (≤ 1 month); -40 ~ 45 (≤ 1 Storage Temperature (℃) month) Mounting Method Rack-mounted/Ground-mounted Round-trip Efficiency 95% Safety Standard and Certification IEC62619,IEC 63056,IEC62040-1,INmetro EN IEC61000-6-1,EN IEC61000-6-2,EN EMC IEC61000-6-3,EN IEC61000-6-4 Transportation UN38.3,ADR *1: Test conditions, 100% DOD, 0.2℃ charge & discharge at +25±2 °C for battery system at beginning life. System Usable Energy may vary with different Inverter. *2: The nominal charge and discharge current and power are affected by temperature and SOC status. *3: Under the condition of using busbar box to achieve parallel connection of batteries. *4: New battery, within the range of 2.5~3.65V, at the temperature range of 25+2℃, under the condition of 0.2C/0.2C charge and discharge. The efficiency is 94%~95% under the charging and discharging condition of 0.6C/0.6C. n:n≤15。 LX Technical Parameters U5. 2*LX U5.4-L 3*LX U5.4-L 4-L 4*LX 5*LX 6*LX U5.4-L U5.4-L U5.4-L Rated energy (kWh) *1 5.4 10.8 16.2 21.6 27 32.4 Usable energy (kWh) *2 4.8 9.6 14.4 19.2 24 28.8 16S5P 16S6P Cell Type Cell Configuration LFP (LiFePO4) 16S 1P 16S2P 16S3P Nominal Voltage (V) 51.2 Operating Voltage Range 48~57.6 (V) Nominal Charge/Discharge Current (A) *3 Max. Discharging Power*3 16S4P 50 100 2.8 5.76 196 8 Short-Circuit Current [email protected] Communication CAN Weight (Kg) 57 Dimensions (W x H x D 114 171 228 285 505×570×175 (LX U5.4-L) mm) Operating Temperature Charge: 0 ~ +50; Discharge: -10 ~ +50 Range (℃) Storage Temperature (℃) -20 ~ 40 (≤ 1 month) ; 0 ~ +35 (≤ 1 year) Relative Humidity 0~95% Max. Operating Altitude 2000 (m) Ingress Protection Rating IP65 Mounting Method Wall-Mounted/GroundMounted Round-trip Efficiency 93.0% Cycle Life *4 ≥4000 @0.5/0.5C Standard Safety IEC62619,IEC 62040,CEC EMC CE,RCM Transportation UN38.3 and Certificat ion 342 安全使用寿命(年) ≥25 *1: Test conditions, Cell Voltage 2.5~3.65V, 0.5C charge & discharge at +25±2 °C for battery system at beginning life. System Usable Energy may vary with different Inverter. *2: Test conditions: Charge and discharge 90% DOD at 0.5C at+25 ± 2 ℃ temperature; *3: Nominal Dis-/Charge Current and power derating will occur related to Temperature and SOC. *4: Based on Cell under 0.5C/0.5C @ 25±2℃ test condition and 80% EOL. LX U5.4-20 Technical Parameters LX U5.4-20 Rated Energy (kWh) *1 Usable Energy (kWh) 5.4 10.8 16.2 5.4 10.8 16.2 Cell Type Cell Configuration 2* LX U5.4-20 3* LX U5.4-20 LFP(LiFePO4) 16S1P 197 16S2P 16S3P Rated Capacity (Ah) 105 Nominal Voltage (V) 210 315 51.2 Rated DC Power (kW) 2.56 Operating Voltage Range (V) 5.12 5.12 47.5~57.6 Nominal Charge/Discharge Current (A) Max. Charging / Discharging Power (kW) Fault current (A) 50 100 2.56 5.12 990 1265 1393 Operating Temperature (°C)*2 -10 ~ +50 Relative Humidity 0 ~ 95% Max. Operating Altitude (m) 2000 Communication CAN, RS485 Weight (kg) 57 114 Dimensions (W x H x D mm) 505 x 570 x 175 (LX U5.4-20) Ingress Protection Rating IP65 Mounting Method Wall Mounted / Grounded Warranty*3 Standard and Certification 171 10 Years Safety IEC62619,IEC 63056,IEC62040,CEC EMC CE, RCM Transportation UN38.3 *1:Test conditions,Cell Voltage 2.5~3.65V,0.5C charge & discharge at +25±2 °C for battery system at beginning life. System Usable Energy may vary with different Inverter. *2: Charge: 0 ~ +50; Discharge: -10 ~ +50. *3: Please refer to the official website for the detailed warranty agreement. LX U5.4-20 Technical Parameters 4*LX U5.4-20 Rated Energy (kWh) *1 Usable Energy (kWh) 6*LX U5.4-20 21.6 27.0 32.4 21.6 27.0 32.4 Cell Type Cell Configuration 5*LX U5.4-20 LFP(LiFePO4) 16S4P 198 16S5P 16S6P Rated Capacity (Ah) 420 525 Nominal Voltage (V) 51.2 Rated DC Power (kW) 5.12 Operating Voltage Range (V) 47.5~57.6 Nominal Charge/Discharge 100 Current (A) Max. Charging / Discharging 5.12 Power (kW) Fault current (A) 1469 1518 Operating Temperature (°C)*2 -10 ~ +50 Relative Humidity 0 ~ 95% Max. Operating Altitude (m) CAN, RS485 Weight (kg) 228 Dimensions (W x H x D mm) 285 342 505 x 570 x 175 (LX U5.4-20) Ingress Protection Rating IP65 Mounting Method Wall Mounted / Grounded Warranty*3 Certification 1552 2000 Communication Standard and 630 10 Years Safety IEC62619,IEC 63056,IEC62040,CEC EMC CE, RCM Transportation UN38.3 *1:Test conditions,Cell Voltage 2.5~3.65V,0.5C charge & discharge at +25±2 °C for battery system at beginning life. System Usable Energy may vary with different Inverter. *2: Charge: 0 ~ +50; Discharge: -10 ~ +50. *3: Please refer to the official website for the detailed warranty agreement. 12.3 Smart Meter Technical Data Technical Parameters Type of Electrical Supply System Input Data Voltage Nominal Voltage (V) 199 GMK110 GMK110D Single phase Single phase 220 220 Voltage Range (V) 85~288 85~288 50/60 50/60 120A:40mA 120A:40mA 1 2 Communication RS485 RS485 Communication distance (m) 1000 1000 User Interface 2 LED 2 LED Accuracy Class 1 Class 1 Active Energy Class 1 Class 1 Reactive Energy Class 2 Class 2 <5 <5 19*85*67 19*85*67 50 50 Rail Installation Rail Installation IP20 IP20 -30 ~ 60 -30 ~ 60 -30 ~ 70 -30 ~ 70 0~95% 0~95% 3000 3000 Nominal Voltage Frequency (Hz) Current Accuracy CT Ratio CT Quantity Power Consumption (w) Dimensions (W x H x D mm) Mechanical Parameters Weight (g) Mounting Method Ingress Protection Rating Operating Temperature Range (℃) Environmenta l Parameters Storage Temperature Range (℃) Relative Humidity (Non-Condensing) Max. Operating Altitude (m) Technical Parameters GM330 Type of Electrical Supply System Nominal Voltage L-N (V) Input Data Voltage Nominal Voltage L-L (V) Three-phase 220/230 380/400 Voltage Range 0.88Un-1.1Un Nominal Voltage 50/60 200 Frequency (Hz) Current CT Ratio nA:5A Communication RS485 Communication distance (m) 1000 User Interface 4 LED, Reset button Accuracy Accuracy Class 0.5 Active Energy Class 0.5 Reactive Energy Class 1 Power Consumption (w) <5 Mechanical Parameters Mechanical 72*85*72 Weight (g) Parameters 240 Mounting Method Rail Installation Ingress Protection Rating Environmental Parameters Operating Temperature Range (℃) -30~+70 Storage Temperature Range (℃) -30~+70 Relative Humidity (No Condensing) 0~95% Max. Operating Altitude (m) 3000 Technical Parameters Type of Electrical Supply System Nominal Voltage L-N (V) Voltage Input Data Current GM1000D GM3000 Single phase Single phase Three-phase 110/230 110/230 110/230 / / 230/400 0.88Un-1.1Un 0.88Un-1.1Un 0.88Un-1.1Un 50/60 50/60 50/60 120A:40mA 120A:40mA 120A:40mA 1 2 3 RS485 RS485 RS485 L-L (V) Voltage Range (V) Frequency (Hz) Current GM1000 Nominal Voltage Nominal Voltage Communication IP20 CT Ratio CT Quantity 201 Communication distance (m) 1000 1000 1000 3 LEDs, Reset 3 LEDs, Reset 3 LEDs, Reset Button Button Button Voltage/Current Class 1 Class 1 Class 1 Active Energy Class 1 Class 1 Class 1 Reactive Energy Class 2 Class 2 Class 2 <3 <3 <3 36*85*66.5 36*85*66.5 36*85*66.5 250 360 450 Rail Installation Rail Installation Rail Installation IP20 IP20 IP20 -25~+60 -25~+60 -25~+60 -30~+70 -30~+70 -30~+70 0~95% 0~95% 0~95% 2000 2000 2000 User Interface Accuracy Power Consumption (w) Dimensions (W * H * D) Mechanical Parameters Weight (g) Mounting Method Ingress Protection Rating Operating Temperature Range (℃) Environmen tal Parameters Storage Temperature Range (℃) Relative Humidity (No Condensing) Max. Operating Altitude (m) 12.4 Smart Dongle Technical Data Technical Parameters WiFi/LAN Kit-20 Output Voltage (V) 5 Power Consumption (W) ≤3 Communication Interface USB Communication Ethernet 10M/100Mbps Self-adaption Wireless IEEE 802.11 b/g/n @2.4 GHz Parameters Bluetooth Mechanical Dimensions (W x H x Parameters D mm) Bluetooth V4.2 BR/EDR and Bluetooth LE standard 48.3*159.5*32.1 202 Weight (g) 82 Ingress Protection Rating Mounting Method IP65 USB port insertion and removal Operating Temperature Range (℃) -30~+60 Storage Temperature Range (℃) -40~+70 Relative Humidity 0-95% Max. Operating Altitude (m) 4000 Technical Parameters Ezlink3000 General Data Connection Interface Ethernet interface (optional) USB 10/100Mbps self-adaption, communication distance ≤100m Mounting Method Plug-and-play Indicator LED indicator status Dimensions (W * H * D mm) 49*153*32 Weight (gram) 130 Ingress Protection Rating IP65 Power Consumption (W) ≤2W (typical value) Working Mode STA Wireless Parameters Bluetooth Communication Bluetooth 5.1 WiFi Communication 802.11 b/g/n(2.412GHz-2.484GHz) Environmental Parameters Operating Temperature Range (℃) -30 ~ +60 Storage Temperature Range (℃) -30 ~ +70 Relative Humidity 0-100% (no condensing) 203 Max. Working Altitude (m) 4000 Technical parameters Wi-Fi Kit General Data Max. Inverters Supported 1 Connection Interface USB Installation Plug and Play Indicator LED Indicator Dimensions (W×H×D mm) 49*96*32 Weight(g) 59 Ingress Protection Rating IP65 Power Consumption (W) 2 Operating Temperature Range (℃) -30 - 60℃ Storage Temperature Range (℃) -40 - 70℃ Relative Humidity 0-100% (non-condensing) Max. Operating Altitude (m) 4000 Wireless Parameter Supported Standards & Frequencies 802.11b/g/n(2.412G-2.472G) Operating Mode AP/STA/AP+STA Technical parameters 4G Kit-CN General Data Max. Number of Connected Devices 1 Connection Interface USB Installation Plug and Play Indicator LED Dimensions (W×H×D mm) 49*96*32 SIM card size (mm) 15*12 204 LS4G Kit-CN Ingress Protection Rating IP65 Power Consumption (W) <4 Operating Temperature -30~60℃ Range (℃) Storage Temperature -40~70℃ Range (℃) Relative Humidity 0-100% (non-condensing) Max. Operating Altitude 4000 (m) Wireless Parameter LTE-FDD B1/B3/B5/B8 LTE-TDD B34/B38/B39/B40/B41 GNSS positioning B3/B8 Technical 4G Kit-CN-G20 parameters 4G Kit-CN-G21 General Data Max. Number of 1 1 Connection Interface USB USB Installation Plug and Play Plug and Play Indicator LED LED 48.3*95.5*32.1 48.3*95.5*32.1 15*12 15*12 IP66 IP66 87g 87g <4 <4 -30~+65℃ -30~+65℃ Connected Devices Dimensions (W×H×D mm) SIM card size (mm) Ingress Protection Rating Weight (g) Power Consumption (W) Operating 205 Temperature Range (℃) Storage Temperature -40~+70℃ -40~+70℃ 0-100% 0-100% 4000 4000 LTE-FDD B1/B3/B5/B8 B1/B3/B5/B8 LTE-TDD B34/B39/B40/B41 B34/B39/B40/B41 GNSS positioning / Beidou, GPS Range (℃) Relative Humidity Max. Operating Altitude (m) Wireless Parameter 206 13 Appendix 13.1 FAQ 13.1.1 How to Perform Meter/CT Detection? Meter/CT detection is used to auto-check if the Smart Meter and CT are connected in the right way and their working status. Step 1 Tap Home > Settings > Meter/CT Assisted Test to set the function. Step 2 Tap Start Test to start test. Check Test Result after test. 13.1.2 How to Upgrade the Device Version Check and upgrade the DSP version, ARM version, BMS version, AFCI version of the inverter, or firmware version of the communication module. Some devices do not support upgrading the firmware version through SolarGo app. Upgrade prompt: If the Firmware Upgrade dialog box pops up once logging into the app, click Firmware Upgrade to directly go to the firmware information page. Regular upgrade: Step 1: Tap Home > Settings > Firmware Information. Step 2: Tap Check for Updates. If there is a new version, complete the upgrade according to the prompts. Forced Upgrade: The APP will push upgrade information, and users need to upgrade according to the prompts; otherwise, they will not be able to use the App. You can complete the upgrade by following the prompts. 13.2 Abbreviations Abbreviation English Description Ubatt Battery Voltage Range Ubatt,r Nominal Battery Voltage Ibatt,max (C/D) Max. Continuous Charging Current 207 Max. Continuous Discharging Current EC,R Rated Energy UDCmax Max. Input Voltage UMPP MPPT Operating Voltage Range IDC,max Max. Input Current per MPPT ISC PV Max. Short Circuit Current per MPPT PAC,r Nominal Output Power Sr (to grid) Nominal Apparent Power Output to Utility Grid Smax (to grid) Max. Apparent Power Output to Utility Grid Sr (from grid) Nominal Apparent Power from Utility Grid Smax (from grid) Max. Apparent Power from Utility Grid UAC,r Nominal Output Voltage fAC,r Nominal AC Grid Frequency IAC,max(to grid) Max. AC Current Output to Utility Grid IAC,max(from grid) Max. AC Current From Utility Grid P.F. Power Factor Sr Back-up Nominal apparent power Smax Max. Output Apparent Power (VA) Max. Output Apparent Power without Grid IAC,max Max. Output Current UAC,r Nominal Output Voltage fAC,r Nominal Output Frequency Toperating Operating Temperature Range IDC,max Max. Input Current UDC Input Voltage UDC,r DC Power Supply UAC Power Supply/AC Power Supply UAC,r Power Supply/Input Voltage Range Toperating Operating Temperature Range Pmax Max Output Power PRF TX Power PD Power Consumption 208 PAC,r Power Consumption F (Hz) Frequency ISC PV Max. Input Short Circuit Current Udcmin-Udcmax Range of Input Operating Voltage UAC,rang(L-N) Power Supply Input Voltage Usys,max Max System Voltage Haltitude,max Max. Operating Altitude PF Power Factor THDi Total Harmonic Distortion of Current THDv Total Harmonic Distortion of Voltage C&I Commercial & Industrial SEMS Smart Energy Management System MPPT Maximum Power Point Tracking PID Potential-Induced Degradation Voc Open-Circuit Voltage Anti PID Anti-PID PID Recovery PID Recovery PLC Power-line Communication Modbus TCP/IP Modbus Transmission Control / Internet Protocol Modbus RTU Modbus Remote Terminal Unit SCR Short-Circuit Ratio UPS Uninterruptable Power Supply ECO mode Economical Mode TOU Time of Use ESS Energy Stroage System PCS Power Conversion System RSD Remote Shutdown EPO Emergency Power Off SPD Surge Protection Device ARC DRED Zero Injection/Zero Export Power Limit / Export Power Limit Demand Response Enabling Device 209 RCR Ripple Control Receiver AFCI AFCI GFCI Ground Fault Circuit Interrupter RCMU Residual Current Monitoring Unit FRT Fault Ride Through HVRT High Voltage Ride Through LVRT Low Voltage Ride Through EMS Energy Management System BMS Battery Management System BMU Battery Measure Unit BCU Battery Control Unit SOC State of Charge SOH State of Health SOE State Of Energy SOP State Of Power SOF State Of Function SOS State Of Safety DOD Depth of Discharge 13.3 Term Explanation Overvoltage category definition Category I: Applies to equipment connected to a circuit where measures have been taken to reduce transient overvoltage to a low level. Category II: Applies to equipment not permanently connected to the installation. Examples are appliances, portables tools and other plug-connected equipment. Category III: Applies to a fixed equipment downstream, including the main distribution board. Examples are switch gear and other equipment in an industrial installation. Category IV: Applies to equipment permanently connected at the origin of an installation (upstream of the main distribution board). Examples are electricity meters, primary over-current protection equipment and other equipment connected directly to outdoor open lines. 210 Moisture location category definition Parameters Moisture Parameters Temperature Range Level 3K3 4K2 4K4H 0~+40℃ -33~+40℃ -33~+40℃ 5% - 85% 15% - 100% 4% - 100% Environment category definition: Outdoor: Ambient Temperature: -25~+60℃, applied to Pollution Degree 3 environment. Indoor Unconditioned: Ambient Temperature: -25~+40℃, applied to Pollution Degree 3 environment. Indoor conditioned: Ambient Temperature: 0~+40℃, applied to Pollution Degree 2 environment. Pollution degree definition Pollution Degree I: No pollution or only dry, non-conductive pollution occurs. The pollution has no influence. Pollution Degree II: Normally only non-conductive pollution occurs. Occasionally, however, a temporary conductivity caused by condensation must be expected. Pollution Degree III: Conductive pollution occurs, or dry. non-conductive pollution occurs, which becomes conductive due to condensation, which is expected. Pollution Degree IV: Persistent conductive pollution occurs, for example, the pollution caused by conductive dust, rain or snow. 211 ">
Download
Advertisement
Key features
Energy Storage System integration
Smart Meter compatibility for energy monitoring
Multiple Battery models supported
Supports parallel system configurations
Remote monitoring via Smart Dongle
Configurable system working modes
Frequently asked questions
The energy storage system consists of an inverter, a battery system, and a smart meter.
Before installations, read through the user manual to learn about the product and the precautions.
Only qualified professionals or trained personnel are allowed to install, operate, maintain, and replace the equipment or parts.