GoodWe MIS Series User Manual
Below you will find brief information for MIS-G10 GW0.799K, MIS-G10 GW0.8K, MIS-G10 GW1K. This user manual provides instructions for installation, electrical connection, commissioning, troubleshooting, and maintenance. The inverter converts DC power from PV modules to AC power, feeding it into the utility grid, and supports both plug-and-play and hardwired PV systems. The manual covers safety precautions, system features, and the use of the SEMS+ App for monitoring and control.
Advertisement
Advertisement
Micro Inverter GW0.799K-MIS-G10 GW0.8K-MIS-G10 GW1K-MIS-G10 User Manual Copyright Statement Copyright ©GoodWe Technologies Co.,Ltd. 2025. All rights reserved. No part of this manual can be reproduced or transmitted to the public platform in any form or by any means without the prior written authorization of GoodWe Technologies Co., Ltd. Trademarks and other GOODWE trademarks are trademarks of GoodWe Technologies Co., Ltd. All other trademarks or registered trademarks mentioned in this manual are owned by the company. NOTICE The information in this user manual is subject to change due to product updates or other reasons. This guide cannot replace the notices and warnings of the device unless otherwise specified. All descriptions in the manual are for guidance only. 1. About This Manual 1.1.Overview This manual describes the product information, installation, electrical connection, commissioning, troubleshooting, and maintenance. Read through this manual before installing and operating the product. All the installers and users have to be familiar with the product features, functions, and safety precautions. This manual is subject to update without notice. For more product details and latest documents, visit https://en.goodwe.com/. 1.2.Applicable Model This manual applies to the listed inverters below: Model Nominal Output Power Nominal Output Voltage GW0.799K-MIS-G10 799W L/N/PE, 220/230/240 GW0.8K-MIS-G10 800W L/N/PE, 220/230/240 GW1K-MIS-G10 1000W L/N/PE, 220/230/240 1.3.Symbol Definition DANGER Indicates a high-level hazard that, if not avoided, will result in death or serious injury. WARNING Indicates a medium-level hazard that, if not avoided, could result in death or serious injury. CAUTION Indicates a low-level hazard that, if not avoided, could result in minor or moderate injury. NOTICE Highlights key information and supplements the texts. Or some skills and methods to solve product-related problems to save time. 2. Safety Precaution Strictly follow the safety instructions in the user manual during the operation. WARNING The products are designed and tested strictly complies with related safety rules. Read and follow all the safety instructions and cautions before any operations. Improper operation might cause personal injury or property damage as the inverters are electrical equipment. 2.1.General Safety NOTICE The information in this user manual is subject to change due to product updates or other reasons. This guide cannot replace the notices and warnings of the device unless otherwise specified. All descriptions in the manual are for guidance only. Before installations, read through the user manual to learn about the product and the precautions. Use insulating tools and wear personal protective equipment when operating the equipment to ensure personal safety. Wear anti-static gloves, cloths, and wrist strips when touching electron devices to protect the inverter from damage. Unauthorized dismantling or modification may damage the equipment, and the damage is not covered under the warranty. Strictly follow the installation, operation, and configuration instructions in this manual. The manufacturer shall not be liable for equipment damage or personal injury if you do not follow the instructions. For more warranty details, please visit: 2.2.System Safety DANGER Disconnect the upstream switches to power off the equipment before any electrical connections. Do not work with power on. Otherwise, an electric shock may occur. All operations such as transportation, storage, installation, use and maintenance shall comply with applicable laws, regulations, standards and specifications. Perform electrical connections in compliance with local laws, regulations, standards and specifications, including operations, cables, and component specifications. Use the connectors included in the package to connect cables. The manufacturer shall not be liable for equipment damage if other connectors are used. Ensure all cables are connected tightly, securely, and correctly. Inappropriate wiring may cause poor connection and damage the equipment. To protect the equipment and components from damage during transportation, ensure that the transportation personnel are professionally trained. All operations during the transportation have to be recorded. The equipment shall be kept in balance to avoid falling down. Keep the equipment stable to avoid dumping, which can result in equipment damage and personal injuries. WARNING Do not apply mechanical load to terminals, otherwise the terminals may be damaged. If the cable bears too much tension, the connection may be poor. Reserve a certain length of the cable before connecting it to corresponding ports. Tie the cables of the same type together, and place cables of different types at least 30mm apart. Do not place the cables entangled or crossed. Place the cables at least 30mm away from the heating components or heat sources, otherwise the insulation layer of the cables may be aging or broken due to high temperature. 2.2.1.PV String Safety WARNING Ensure the PV module frames and the bracket system are securely grounded. Ensure the DC cables are connected tightly, securely and correctly. Inappropriate wiring may cause poor contacts or high impedances, and damage the inverter. Measure the DC cable using a multimeter to avoid reverse polarity connection. Also, the voltage should be under the max DC input voltage. The manufacturer shall not be liable for the damage caused by reverse connection and overvoltage. The PV strings cannot be grounded. Ensure the minimum insulation resistance of PV string to the ground meets the minimum insulation resistance requirements before connecting the PV string to the inverter (R=maximum input voltage (V)/ 30mA). Do not connect one PV string to more than one inverter at the same time. Otherwise, it may cause damage to the inverter. PV modules used with inverters must comply with IEC 61730 Class A standard. 2.2.2.Inverter Safety WARNING The voltage and frequency at the connecting point should meet the on-grid requirements. 2.3.Safety Symbols and Certification Marks DANGER All labels and warning marks should be visible after the installation. Do not cover, scrawl, or damage any label on the equipment. The following descriptions are for reference only. No. Symbol Descriptions Potential risks exist. Wear proper personnel protective 1 equipment before any operations. HIGH VOLTAGE HAZARD. Disconnect all incoming power and 2 turn off the product before working on it. High-temperature hazard. Do not touch the product under 3 operation to avoid being burnt. Delayed discharge. Wait 5 minutes after power off until the 4 components are completely discharged. 5 Read through the user manual before any operations. Do not dispose of the equipment as household waste. Discard 6 the product in compliance with local laws and regulations, or send it back to the manufacturer. 7 CE mark. 2.4.EU Declaration of Conformity 2.4.1.Equipment with Wireless Communication Modules GoodWe Technologies Co., Ltd. hereby declares that the equipment with wireless communication modules sold in the European market meets the requirements of the following directives: Radio Equipment Directive 2014/53/EU (RED) Restrictions of Hazardous Substances Directive 2011/65/EU and (EU) 2015/863 (RoHS) Waste Electrical and Electronic Equipment 2012/19/EU Registration, Evaluation, Authorization and Restriction of Chemicals (EC) No 1907/2006 (REACH) 2.4.2.Equipment without Wireless Communication Modules GoodWe Technologies Co., Ltd. hereby declares that the equipment without wireless communication modules sold in the European market meets the requirements of the following directives: Electromagnetic compatibility Directive 2014/30/EU (EMC) Electrical Apparatus Low Voltage Directive 2014/35/EU (LVD) Restrictions of Hazardous Substances Directive 2011/65/EU and (EU) 2015/863 (RoHS) Waste Electrical and Electronic Equipment 2012/19/EU Registration, Evaluation, Authorization and Restriction of Chemicals (EC) No 1907/2006 (REACH) 3. System Introduction 3.1.Product Overview The MIS inverter is a micro single-phase grid-tied PV inverter. The inverter converts the DC power generated by the PV module into AC power and feeds it into the utility grid. The application scenario of the inverter is plug and play PV system, as follows: The application scenario of the inverter is hardwired system, as follows: Obtain the local grid license before connecting to the grid. Supports connecting one or more PV modules. Ensure the DC input from the PV system meets the following requirements: Open-circuit voltage does not exceed 60V, short-circuit current does not exceed 20A, and the power of each module is between 180Wp and 480Wp. The inverter supports connecting to SEMS+ App or SolarGo App(installar only) via bluetooth to configure router information. And then connecting to SEMS+ App via WiFi to realize remote monitoring and control of inverters and power stations. Install the smart meter or not based on actual needs. If installation is required, prepare a wireless smart meter by yourself and connect it via WiFi to enable functions such as power limitation. For installation methods and precautions regarding the wireless meter, please refer to the corresponding meter manual. Currently supported meter models: Fineco EM115-Mod-WL (single-phase), Shelly Pro 3EM (three-phase), etc. When connecting a wireless smart meter in a hardwired scenario—only where local regulations permit—if multiple inverters need to be connected to a three-phase grid, ensure that CTs are installed on L1, L2, and L3, as shown in the diagram below. 3.2.Supported Grid Types 3.3.Features Power derating To satisfying the local laws or regulations and ensuring a safe operation, the inverter will automatically reduce the output power when the operating environment is not ideal. The following are the factors that may occur power derating. Please try to avoid then during operations. Unfavorable environmental conditions, e.g., direct sunlight, high temperature, etc. Inverter's output power percentage has been set. Over-frequency derating. Higher input current value. Communication Setting the inverter via bluetooth in a short distance; or connecting the inverter to the server via WiFi to monitor the inverter and power station working status. Bluetooth: meets Bluetooth 5.0 standard. WiFi: supports 2.4G frequency band. Set the router to 2.4G or 2.4G/5G mode. The router wireless signal name supports a maximum input of 32 bytes. To ensure communication quality, it is recommended to select a router with high wireless gain or more antennas. Use a wireless repeater or outdoor router if needed. 3.4.Circuit Diagram 3.5.Appearance 3.5.1.Parts No. Parts Descriptions 1 Handle Moves or hangs the inverter. Connects the grounding cable to the grounding points for 2 Grounding point protection. If the AC plug is grounded, no additional grounding cable is required. Connects the inverter to the PV module. Connector model: 3 PV connector 4 Antenna 5 AC connector 6 LED indicator Indicates working state of the inverter. 7 Heat sink Used for heat dissipation of inverters. MC4. Wireless communication; supports WiFi/bluetooth. Connects the AC cable to provide AC output power to household loads. 3.5.2.Dimensions 3.5.3.Indicators Indicator status Descriptions Slow blinking green = Equipment on and in the standby mode. Fast blinking green = equipment starting and in the self-check mode. Steady green = The two PV inputs are available, and the inverter is feeding power to the grid properly. Blinking green and red = Not all PV inputs are available, but the inverter is still feeding power to the grid. The two blinks represent the status of PV1 and PV2 respectively. A red blink indicates abnormal PV input, and a green blink indicates normal PV input. Example: As shown on the left, PV1 is abnormal, and PV2 is working normally. Double blinking red = Utility grid fault. Steady red = Equipment fault. Fast blinking green and red = Updating software. 3.5.4.Nameplate The nameplate is for reference only. No. Descriptions 1 GW trademark, producy type, and producth model. 2 Technical parameters. 3 Safety symbols and certification marks. 4 Contact information and serial number. 4. Check and Storage 4.1.Check Before Receiving Check the following items before accept the product. Check the outer packing box for damage, such as holes, cracks, deformation, and other signs of equipment damage. Do not unpack the package and contact the supplier as soon as possible if any damage is found. Check the product model. If the product model is not what you requested, do not unpack the product and contact the supplier. Check the deliverables for correct model, complete contents, and intact appearance. Contact the supplier as soon as possible if any damage is found. 4.2.Package Content NOTICE Connect the PV cables using the connectors in correct model. The manufacturer shall not be liable for the damage if other connectors are used. The actual number of accessories may differ. The optional accessories can be purchased from the manufacturer based on your actual needs. The accessories will be delivered separately. The actual number of accessories may differ. Parts Descriptions Parts Descriptions Inverter x 1 Expansion screws x 2 Flange nuts x 1 Assembly bolts x 2 PV fastening tool x 4 Unlock tool for PV and AC connectors x 1 Documents x 1 The delivered AC connector and cable for plug and play system are as following: Parts Descriptions Parts Descriptions - - AC cable AC cable length: 5m, 10m, or 15m. Only for the plug and play scenario. For hardwired inverter installations, AC connectors and cables must be purchased separately. The quantities listed below are for reference only, actual accessory requirements may vary. Parts Descriptions Parts T-shape AC connector The quantity of with cable x 1 connectors Number of the matches the connector and number number of of the inverter are the inverters. same. Unlock tool for PV PIN terminal x N connectors x N Unlock tool for T-shape AC connectors x N Descriptions - - 4.3.Storage If the equipment is not to be installed or used immediately, please ensure that the storage environment meets the following requirements: 1. Do not unpack the outer package. 2. Store the equipment in a clean place. Make sure the temperature and humidity are appropriate and there is no condensation. 3. The height and direction of the stacking products should follow the instructions on the packing box. 4. The product must be stacked with caution to prevent them from falling. 5. If the inverter has been stored for more than two years or has not been in operation for more than six months after installation, it is recommended to be inspected and tested by professionals before being put into use. 6. To ensure good electrical performance of the internal electronic components of the inverter, it is recommended to power it on every 6 months during storage. If it has not been powered on for more than 6 months, it is recommended to to be inspected and tested by professionals before being put into use. 5. Installation 5.1.Installation Requirements Installation Environment Requirements Do not install the equipment in a place near flammable, explosive, or corrosive materials. The temperature and humidity at the installation site should be kept within the appropriate range. Do not install the equipment in a place that is easy to touch, especially within children’s reach. When the equipment is working, its temperature may be high. Do not touch the surface to avoid burn. Install the equipment in a sheltered place to avoid direct sunlight, rain, and snow. The place to install the equipment shall be well-ventilated for heat radiation and large enough for operations. Install the equipment at a height that is convenient for operation and maintenance, electrical connections, and check indicators and labels. The altitude to install the equipment shall be lower than the maximum working altitude of the system. Mounting Support Requirements The mounting support shall be nonflammable and fireproof. Ensure the mounting support is solid enough to bear the inverter weight. Installation Tool Requirements The following tools are recommended when installing the equipment. Use other auxiliary tools on site if necessary. Tool Descriptions Tool Descriptions Goggles Safety shoes Safety gloves Dust mask Socket wrench set Impact drill M8 Marker Level Torque wrench Rubber hammer M6 Cable tie Vacuum cleaner Multimeter - - 5.2.Installing the Inverter CAUTION Move the equipment to the site before installation. Follow the instructions below to avoid personal injury or equipment damage. 1. Do not bump or hit the antenna. Otherwise, the antenna may be damaged. 2. Instead of lifting the cables directly, it is recommended to hold the handle of the inverter to prevent potential damage to the cables. NOTICE For plug and play installation, plan the installation position reasonably and make sure the cable lengths between the inverter, PV and socket are sufficient. For hardwired installation, consider the AC cable length and plan the installation position reasonably. Wall installation Step 1 Confirm the installation location based on the layout plan, and mark the drilling positions with a marker pen. Step 2 Drill holes at the marked positions, then install the expansion screws. Hole diameter: 8mm. Hole depth: 45mm. Step 3 Hang the inverter onto the expansion screws and tighten the screws with a torque wrench. PV Rail Mounting Step 1 Prepare the PV rails that meet the required specifications, and confirm the installation location according to the layout plan. Step 2 Insert the assembly bolts into the PV rail from the side. Step 3 Hang the inverter onto the assembly bolts and tighten the flange nuts using a socket wrench. 6. Electrical Connection 6.1.Connecting the PE Cable (Hardwired Scenario) When multiple inverters are installed in a hardwired scenario, the PE cable should be connected to ensure system safety. WARNING 1. Ensure that the equipment is reliably grounded before operations. 2. To improve the corrosion resistance of the terminal, you are recommended to apply silica gel or paint on the ground terminal after installing the PE cable. 3. The PE cable, grounding OT terminal and screw should be prepared by the customer. Recommended specifications: PE cable: outdoor copper cable, conductor cross-sectional area: 6mm2. OT terminal: M4 Screw: M4 6.2.Connecting PV cables DANGER Ensure the PV connectors are connected with correct polarity. To prevent PV cables from disconnecting, install the PV fastening tool. The fastening tool is only suitable for MC4 PV connectors. Step 1 Take out the PV fastening tool included in the package and install it onto the PV connector of the inverter. Step 2 Plug the PV connector of the PV module into the PV connector of the inverter. 6.3.Connecting the AC Cable Scenario 1: plug and play DANGER Ensure the AC plug matches the specifications of the socket. Step 1 Insert the AC cable included in the package into the AC connector of the inverter. Step 2 Plug the other end of the cable into the household socket. The inverter will power on and start working. Scenario 2: hardwired NOTICE The AC cable assembly includes 21 T-type connectors as standard. Before use, split the AC cable according to the number of inverters, ensuring the retained T-type connectors match the inverter count. The included AC cable has pre-cut segments at 2.5m intervals. If this length is insufficient, prepare additional compliant AC cables. For extended cabling needs, refer to local regulations and the table below to source approved AC cable extensions. T-shape connector AC cable specification (AC cable specification) Maximum number per branch 10AWG 8 12AWG 6 14AWG 4 Step 1: Take out the AC cable and verify the required number of T-shape connectors. Step 2: Use the included connector unlock tool to detach the terminal T-type connector from the AC cable. Loosen the internal screw of the detached T-type connector. Step 2: Remove the crimped AC cable from the connector. Step 3: The included AC cable has a fixed segment length of 2.5m. If the length is sufficient, directly connect the terminal AC cable to the distribution box. If extended length is required, replace the terminal cable with a user-provided compliant extension, then connect it to the T-type connector before linking to the distribution box. Step 4: Attach the inverter-side AC connectors to the corresponding T-shape connectors on the AC cable sequentially. Step 5: Install the waterproof plug at the end of the starting T-shape connector. 7. System Trial Operation 7.1.Check Before Power ON No. 1 Check Item The inverter is firmly installed in a clean place where is well-ventilated and easy to operate. 2 The PE, DC input and AC output cables are connected correctly and securely. 3 Cable ties are intact, routed properly and evenly. 4 Unused cable holes are sealed. 5 The voltage and frequency at the connecting point should meet the on-grid requirements. 7.2.Power ON A. Plug and play scenario: complete all electrical connections and plug the AC power cord directly into a standard household outlet. B. Hardwired scenario: complete all electrical connections, energize the system by connecting the AC circuit breaker in the distribution panel. 8. System Commissioning The hardwired system should be configured by installers via SolarGo App, including safety code, operating paramters, etc. SolarGo App is a mobile application that communicates with the inverter through bluetooth or WiFi modules. Commonly used functions are as follows: Check the operating data, software version, alarms, etc. Set grid parameters, communication parameters, safety countries, power limitation, etc. Equipment maintenance. Visit the official websitehttps://en.goodwe.com/Ftp/EN/Downloads/User%20Manual/GW_SolarGo_User%20Manu al-EN.pdf or scan the QR code to read the SolarGo APP User Manual for more details. SolarGo App User Manual SolarGo App 9. Plant Configuration and Monitoring 9.1.Introduction to SEMS+ App NOTICE The version of the App corresponding to the screenshots in this manual is V1.7. The screenshots are for reference only. SEMS+ App is a monitoring platform to manage power stations and devices. Commonly used functions: 1. Manage user information. 2. Add, monitor the power station or devices. 3. Equipment maintenance. The App structure is as following: Primary menu Submenu Login & Register - Third-Level Fourth-Level Fifth-Level Menu Menu Menu - - - Monitoring Overview - - - Create Station - - - Station List - - - Monitoring - - Add Device - Information Search Device Device List Device Replace Device Edit Device Delete Device Device Device Details Station Station Details - - Edit Station - Delete Station - Replacement Station Configuration History User Information Home Configuration Services Services Tools Device Remote Control Alarms Create Station Monitoring Info - - - - - - Warranty - - Report Center - - GoodWe News - - Announcements - - Community - - Create Station - - Network Link - - Help - - - User Profile - - - User Information - - - Setting - - - Email - - Password - - Close Account - - - - Monitoring Auth - - Apps - - - About - - - Logout - - - - Account Security Remote Control My Auth Management Logout Auth Login anther Account 9.2.Downloading and Installing the App Make sure that the mobile phone meets the following requirements: Operating system: Android 6.0 or later, iOS 13.0 or later. Internet connection via browser. WLAN/Bluetooth capabilities. Download Methods: Method I Search SEMS+ on Google Play (Android) or App Store (iOS) to download and install the App. Method II Scan the QR code below to download and install the App. 9.3.Managing the Account 9.3.1.Registering an Account Step 1 Tap Register and enter the account information based on actual situation. 9.3.2.Logging in to the App Step 1 Enter the username and password, tap Log In. 9.4.Quick Configuration For new accounts registering for the first time, please follow the on-screen instructions to complete the quick configuration of the station. After the quick configuration is completed, you can view the station and related monitoring information for its devices. Step 1 Log in to the SEMS+ App using the newly registered account and password. Step 2 Tap > Start to enter the station creation interface. Step 3 Set the station-related information according to your actual situation. Tap Save & Continue to proceed to the Add Device interface. Step 4 Scan the SN code on the device label to automatically populate the device information, or manually enter the information. After completing the addition, tap Done to go to the Search Device interface. Step 5 Tap Search Device, and the app will automatically search for nearby devices. Once the desired microinverter is found, tap the device name (WNN-***, where *** represents the 16-digit device serial number). Enter the login page. Step 6 Log in as User (default password: 1234). For security, the interface will prompt to change the default password. Follow the instructions to set a new password, then log in again using the newly created password. Then enter the Device Configuration page. Step 7 Enable “Bluetooth Stays On” based on actual needs. Enable the function, the bluetooth of the device will be contentious on to keep connected to SEMS+. Otherwise, the bluetooth will be off in 5 minutes. Step 8 Select the router the device should connect to based on actual needs. Once the device connects to the router, the station or device information can be viewed through the App. Ensure the router signal is stable for a reliable connection to the device. After completing the setup, tap Next. Step 9 Select the safety region or country based on actual requirements. After completing the settings, tap Next. Step 10 Confirm the device list and tap Next to finish creating the station and adding devices. No. Parameter Descriptions Create Station 1 Station Name Set the power station name. 2 Station Address Set the station address based on actual situation. 3 Station Category Select the station type. Recommended category: Residential Grid-tied. 4 Currency Select the currency type. 5 Station Capacity Set the station capacity based on the total power of the PV modules. 6 Modules Set the number of the PV module in the station. 7 Rate of Revenue Set the rate revenue of the station. 8 Station Profile Photo Take station photos and set the photo as the profile photo. 9.5.Station Monitoring 9.5.1.Checking Overview Information of All Stations After logging in, you can view an overview of all stations linked to your account from the homepage. Or sort the list of all power stations through different sorting and filtering conditions on the power station page to view the detailed information of the power stations. No. Descriptions Displays the overall generation information of all stations, including: Generation 1 Today, Generation This Month, Generation This Year, and Generation Lifetime. Generation This Year will not be displayed if the station amount exceeds 10. Displays the total installed capacity and the working status of the stations. Working 2 status: Running, Waiting, Offline, and Fault. The stations status is Running only when all the devices of the station are working properly. Displays statistical chart of Generation Today, This Year, and Lifetime. Or displays 3 comparison chart comparing current and past generation. Tap to expand the chart. 4 5 6 Displays environmental contributions like CO₂ Reduction, Trees Stationed Equivalent, Standard Coal Saved. Creating a new station. Searching Stations. Enter the device SN, power station name or email address to quickly search for the corresponding power station. Power station operation status. Display the current operation status of power 7 stations and the number of power stations operating in each status. Tap the operation status to filter power stations in the corresponding operation status. Set KPI indicators displayed in the power station list: Current Power, Rev. Today, Rev. Total, Gen. Today, Gen. Total. 8 Set the sorting method of the power station list: By Default, By Capacity. Set the display mode of the power station list: Station Card, Station List. Set the filtering conditions for the power station list: Scope, Category, Capacity. Power station list. Tap the power station name to view the detailed information of 9 the power station. The displayed content varies depending on the station type. The actual interface takes precedence 9.5.2.Checking Detailed Information of Single Station Select the device to find the specific information of the device. No. Descriptions 1 The current name of the power station. 2 Favoriting a station. 3 Configuring Station Information. Supported functions: Configure basic information of the power station, modify user information, add power station photos, set PV module layout, etc. Displays current power station operation information in chart form, such as energy 4 flow diagrams, power generation, load power consumption, AC output, and other information. Device List Displays devices in the current power station, such as inverters, batteries, 5 data collectors, charging piles, etc. • • Tap the device card to view detailed device information. 6 Alarm information. 9.5.3.Checking Alarm Information Method 1: Alarms of a specific station. Step 1 Select a station from the station list. Step 2 Tap Alarms and select an alarm to view detailed information. Tap to filter the alarms as needed. Method 2: Alarms of a specific device. Step 1 Select a station from the station list. Step 2 Tap Device and select a device to enter the device page. If alarms exist, the latest 10 active alarms will be displayed. 9.5.4.Checking Station Reports Viewing Reports Step 1 Tap Service > Report Center. Step 2 Select a time period, search for the desired station, and tap the station name to view the report center. Tap > Export to download the report if needed. Viewing Bills Step 1 Tap Service > Report Center. Step 2 Search for the desired station. Find the station, swipe left and tap details of the month. to view billing 9.6.Setting the Network Information The SEMS+ App allows connecting devices via Bluetooth and configuring network parameters to realize remote monitoring or management via WiFi. NOTICE Before connecting, ensure: Your phone’s Bluetooth is turn on. The device is powered on and communicating properly. Step 1 Open the app and select Network Link on the homepage or in the Service interface. Step 2 Tap Bluetooth and select the device by the serial number. Step 3 Log into the App as User and enter the password. Default password: 1234. If no login prompt appears, you will directly enter the communication settings interface. Step 4 (Optional) Enable WLAN Control, Remote Maintenance or Modbus TCP if required. Step 5 Set the WLAN parameters based on actual situation. Tap Save to complete settings. Tap WLAN Detection to check the communication status. Step 6 (optional) Tap Login Password Change to input a new password, and Save. No. Parameter Descriptions Privacy&Security 1 2 Bluetooth Stays ON WLAN Control Enable the function, the bluetooth of the device will be contentious on to keep connected to SEMS+. Otherwise, the bluetooth will be off in 5 minutes. Enable the function, the device and the App can be connected through the WLAN when they are on the same LAN. Otherwise, they cannot be connected even if they are on the same LAN. 3 4 Remote Maintenance Modbus TCP Enable the function, the after-sales service center will remotely upgrade the version of the communication module. Enable the function, the third party monitoring platform can access inverter through Modbus-TCP communication protocol. WLAN/LAN 5 WLAN Enable or disable WLAN. 6 Name Select the name of the router network to be used and enter its 7 Password password. 9.7.Managing Device Remotely NOTICE Set the device parameters via SEMS+ App after creating a plant and adding devices to it. Before setting any parameters, read through user manual to learn the product functions and features. Incorrectly configured parameters, such as grid settings or start/stop commands, may result in devices failing to connect to the grid, potentially affecting power generation. Step 1 If there are more than one station, select a station from the station list. Step 2 Tap Device to enter the device page and choose the device to be configured. Step 3 Tap , read the prompts and set parameters as needed. No. Parameter Effective for this 1 inverter / Effective for all inverters Descriptions Effective for this inverter: Effective for this inverter: Applies settings to a single inverter. Effective for all inverters: Effective for all inverters: Applies settings to all inverters in the network. Inverter Restart: Restart the inverter. 2 Start/Stop Inverter stops generating electricity: The inverter stops generating electricity. Set the inverter active power output value. 3 Active Power For example: When the setting value is 90%, it means the active power output value of the inverter = the inverter rated power * 90%. 4 On-grid Settings Power Limit Enable: Enable power limit when power limiting is required by local grid standards and requirements. Power Limit Value: Set the maximum power that is allowed feed into the utility grid based on local grid standards and requirements. Advanced Settings: Power Limit Mode: When the mode is Split-phase Power, the max power of the phase will be limited. When the smart meter is a three phase meter, set the mode to Total Power to limit the totoal power of three phases. Power Regulation Time Interval: When the power limit function is enabled, all inverters will adjust the output power at intervals based on the load conditions. The smaller the set value, the faster the power limit response speed. Default value: 900ms. Set the value reasonably according to the actual situation on site, otherwise it may cause power oscillation. Communication Timeout Duration: Protection measures can be taken when the communication between the inverter and the smart meter is abnormal. Communication Timeout Handling: when the communication between the inverter and the smart meter is abnormal, the equipment should stop working or continue working at the percentage of the rated power. 10. System Maintenance 10.1. Power Off NOTICE To reset the bluetooth password, power off the inverter and wait for 20-30s, then power it back on. A. Plug and play scenario: unplug the AC plug from the household outlet. B. Hardwired scenario: turn off the AC circuit breaker in the distribution panel. 10.2. Removing the Inverter WARNING Make sure that the inverter is powered off. Wear proper PPE before any operations. Step 1 Disconnect all the cables, including PV cable and AC cables. Step 2 Remove the inverter. Step 3 Store the inverter properly. If the inverter needs to be used later, ensure that the storage conditions meet the requirements. 10.3. Disposing of the Inverter If the inverter cannot work anymore, dispose of it according to the local disposal requirements for electrical equipment waste. The inverter cannot be disposed of together with household waste. 10.4. Routine Maintenance DANGER Before maintaining the equipment, take necessary protective measures to prevent electric shock. During maintenance, ensure that both upstream and downstream switches of the equipment are disconnected. Strictly follow proper operating procedures during maintenance. WARNING Contact after-sales service for help if the copper conductor is exposed. Do not touch or disassemble privately because high voltage danger exists. In case of other emergencies, contact the after-sales service as soon as possible. Operate following the instructions or wait for the after-sales service personnel. Maintaining Item System Clean System installation Electrical connection Maintaining Method Maintaining Period Check whether the installation space meets requirements and whether there is any debris around the device. Once half a year 1. Check whether the equipment are installed securely and whether the screws are installed tightly. Purpose Prevent heat dissipation failures. Ensure that the Once 6-12 months 2. Check whether the equipment is damaged or deformed. Check whether the cables are securely connected. Check whether the cables are broken or whether Maintaining equipment is installed securely. Once 6-12 months Confirm the reliability of electrical connections. there is any exposed copper core. 10.5. Troubleshooting Perform troubleshooting according to the following methods. Contact the after-sales service if these methods do not work. Collect the information below before contacting the after-sales service, so that the problems can be solved quickly. 1. Product information like serial number, software version, installation date, fault time, fault frequency, etc. 2. Installation environment, including weather conditions, whether the PV modules are sheltered or shadowed, etc. It is recommended to provide some photos and videos to assist in analyzing the problem. 3. Utility grid situation. No. Fault Cause Solutions The grid voltage exceeds the 1. If the problem occurs permissible range, or the occasionally, the utility grid duration of high voltage exceeds may be abnormal the requirement of HVRT. temporarily. The inverter will recover automatically after detecting that the utility grid is normal. 1 2. If the problem occurs Grid frequently, check whether the Overvoltage grid voltage is within the permissible range. 3. Check whether the AC breaker and the output cables are connected securely and correctly if the problem persists. The grid voltage is lower than the 2 Grid Undervoltag e 1. If the problem occurs permissible range, or the occasionally, the utility grid duration of low voltage exceeds may be abnormal the requirement of LVRT. temporarily. The inverter will recover automatically after detecting that the utility grid is normal. 2. If the problem occurs frequently, check whether the grid voltage is within the permissible range. 3. Check whether the AC breaker and the output cables are connected securely and correctly if the problem persists. Utility grid exception. The actual 3 1. If the problem occurs grid frequency exceeds the occasionally, the utility grid requirement of the local grid may be abnormal standard. temporarily. The inverter will recover automatically after Grid detecting that the utility grid Overfrequen is normal. cy 2. If the problem occurs frequently, check whether the grid frequency is within the permissible range. Utility grid exception. The actual 4 1. If the problem occurs grid frequency is lower than the occasionally, the utility grid requirement of the local grid may be abnormal standard. temporarily. The inverter will recover automatically after Grid detecting that the utility grid Underfreque is normal. ncy 2. If the problem occurs frequently, check whether the grid frequency is within the permissible range. The grid voltage is abnormal or Grid Rapid 5 Overvoltage ultra high. 1. If the problem occurs occasionally, the utility grid may be abnormal temporarily. The inverter will recover automatically after detecting that the utility grid is normal. 2. If the problem occurs frequently, check whether the grid voltage is within the permissible range. 3. Check whether the AC breaker and the output cables are connected securely and correctly if the problem persists. 6 The moving average of grid If the problem occurs frequently, Grid 10min voltage in 10min exceeds the check whether the grid frequency Overvoltage range of safety requirements. is within the permissible range. If not, contact the local power company. 孤岛保护 Anti-islandin g The utility grid is disconnected. 1. If the problem occurs The utility grid is disconnected occasionally, the utility grid according to the safety may be abnormal regulations, but the grid voltage temporarily. The inverter will is maintained due to the loads. recover automatically after detecting that the utility grid 7 is normal. 2. If the problem occurs frequently, check whether the grid frequency is within the permissible range. Utility grid exception. The 1. If the problem occurs LVRT duration of the utility grid occasionally, the utility grid Undervoltag exception exceeds the set time of may be abnormal e HVRT. temporarily. The inverter will recover automatically after detecting that the utility grid 8 is normal. 2. If the problem occurs frequently, check whether the grid voltage and frequency are within the permissible range. If not, contact the local power company. Utility grid exception. The 3. If the problem occurs HVRT duration of the utility grid occasionally, the utility grid Overvoltage exception exceeds the set time of may be abnormal HVRT. temporarily. The inverter will recover automatically after detecting that the utility grid is normal. 9 4. If the problem occurs frequently, check whether the grid voltage and frequency are within the permissible range. If not, contact the local power company. The DC component of the output 10 11 Level1 DCI current exceeds the safety range abnormal or default range. 1. If the problem is caused by an external fault like a utility grid exception or frequency exception, the inverter will recover automatically after solving the problem. 2. If the problem occurs frequently and the PV station Level2 DCI cannot work properly, abnormal contact the dealer or the after-sales service. Low 12 Insulation Res. 13 14 Flash R/W abnormal 1. The PV string is short-circuited to PE. 2. The PV system is in a moist environment and the cable is not well insulated to the ground. 1. Check whether the resistance of the PV string to PE exceeds 50kΩ. If no, check the short circuit point. 2. Check whether the PE cable is connected correctly. The internal Flash storage is abnormal. Disconnect the AC output switch and DC input switch, then connect them 5 minutes later. Contact the dealer or the after-sales service if the problem persists. 1. The installation location of the 1. Check whether the ventilation Cavity Overtemper ature inverter is not ventilated. 2. The ambient temperature exceeds 60℃. 3. Internal fan working abnormally of the inverter installation location is good and whether the ambient temperature exceeds the maximum allowable ambient temperature range. 2. If the ventilation is poor or the ambient temperature is too high, improve the ventilation and heat dissipation conditions. 3. Contact the dealer or after-sales service if both the ventilation and the ambient temperature are normal. 15 The PV array configuration is not Check the serial connection of the PV Input correct. Too many PV panels are PV array. Make sure that the Overvoltage connected in series in the PV open circuit voltage of the PV string. string is not higher than the maximum operating voltage of the inverter. PV 16 Continuous 1. The PV configuration is not proper. Hardware 2. The hardware is damaged. Overcurrent PV 17 Continuous 3. The PV configuration is not proper. Software 4. The hardware is damaged. Overcurrent 18 Disconnect the AC output switch and DC input switch, then connect them 5 minutes later. Contact the dealer or the after-sales service if the problem persists. The PV strings are connected reversely. Check whether the PV strings are connected reversely. 1. The MOS is abnormal. Disconnect the AC output switch MOS once 2. The PV voltage is too high. and PV cables, then connect them Overvoltage 3. The MOS voltage sampling is PV String Reversed 19 Disconnect the AC output switch and DC input switch, then connect them 5 minutes later. Contact the dealer or the after-sales service if the problem persists. abnormal. 5 minutes later. Contact the dealer or the after-sales service if the problem persists. 20 A sudden change in the grid or Contact the dealer or the load causes an overcurrent. after-sales service if the problem persists. 11. Technical Parameters Technical GW0.799K-MIS-G10 GW0.8K-MIS-G10 GW1K-MIS-G10 Max. Input Power (W) 960 960 1350 Max. Input Voltage (V) 60 60 60 Nominal Input Voltage (V) 42 42 42 Min. Start-up Voltage (V) 15 15 15 MPPT Operating Voltage Range (V) 13-60 13-60 13-60 Max. Input Current (A) 18/18 18/18 18/18 Max. Input Short Circuit Current (A) 20/20 20/20 20/20 Number of MPP Trackers 2 2 2 1 1 1 Nominal Output Power (W) 799 800 1000 Max. Continuous Output Power (W) 799 800 1000 Nominal Apparent Power (VA) 799 800 1000 Max. AC Apparent 799 800 1000 parameters Input Number of Strings per MPPT Output Power (VA) Nominal Output Voltage (V) L/N/PE, 220/230/240 L/N/PE, 220/230/240 L/N/PE, 220/230/240 Output Voltage Range (V) 176 - 264 176 - 264 176 - 264 Nominal Output Frequency (Hz) 50/60 50/60 50/60 AC Grid Frequency Range (Hz) 50/60 ±5 50/60 ±5 50/60 ±5 3.50 @220 V 3.50 @220 V 4.54 @220 V 3.47 @230 V 3.48 @230 V 4.35 @230 V 3.33 @240 V 3.33 @240 V 4.17 @240 V ~1 default ~1 default ~1 default -0.8 leading … +0.8 -0.8 leading … +0.8 -0.8 leading … +0.8 lagging adjustable lagging adjustable lagging adjustable < 3% < 3% < 3% 96.4% 96.4% 96.4% 94.0% 94.0% 94.0% 99.8% 99.8% 99.8% -40℃ ~ 65℃ (Derating -40℃ ~ 65℃ (Derating -40℃ ~ 65℃ (Derating temperature 45℃) temperature 45℃) temperature 45℃) 0~100% 0~100% 0~100% Max. Continuous Output Current (A) Power Factor (@nominal power) Max. Total Harmonic Distortion Efficiency Max. Efficiency European Weighted Efficiency Nominal MPPT efficiency General Data Operating Temperature Range (℃) Relative Humidity Max. 0~2000 0~2000 0~2000 Natural convection Natural convection Natural convection 3.3kg 3.3kg 3.3kg 256 × 210 × 34 256 × 210 × 34 256 × 210 × 34 IP67 C4M IP67 C4M IP67 C4M DC II / AC III DC II / AC III DC II / AC III Built-in Wi-Fi and Built-in Wi-Fi and Built-in Wi-Fi and on Bluetooth Bluetooth Bluetooth Monitoring SEMS+ APP SEMS+ APP SEMS+ APP Operating Altitude (m) Cooling Method Weight (kg) Dimensions (W×H×D mm) Ingress Protection Rating Overvoltage Category Features Communicati Protection PV Insulation Resistance Detection, PV Reverse Polarity Protection, Anti islanding Protection, AC Overcurrent Protection, AC Short Circuit Protection, AC Overvoltage Protection, Type III AC Surge Arrester Warranty Topology 12 Years Standard, 25 12 Years Standard, 25 12 Years Standard, 25 Years Optional Years Optional Years Optional Galvanically Isolated HF Galvanically Isolated HF Galvanically Isolated HF Transformer Transformer Transformer IEC62109, VDE 0126-95, VDE 4105:2018, EN 50549-1:2019+EN 50549Compliance 10, ETSI/EN 303645, EN 18031, IEC61000, EN300328, EN301489, EN IEC 62311, IEC62920 12. Appendix 12.1. FAQ 12.1.1. Step 1: Tap How to find SEMS+ App User Manual > User Manual on the app login page. 12.2. Acronyms and Abbreviations Acronyms EN Description Ubatt Battery Voltage Range Ubatt,r Nominal Battery Voltage Ibatt,max (C/D) Max. Continuous Charging Current Max. Continuous Discharging Current EC,R Rated Energy UDCmax Max.Input Voltage UMPP MPPT Operating Voltage Range IDC,max Max. Input Current per MPPT ISC PV Max. Short Circuit Current per MPPT PAC,r Nominal Output Power Sr (to grid) Nominal Apparent Power Output to Utility Grid Smax (to grid) Max. Apparent Power Output to Utility Grid Sr (from grid) Nominal Apparent Power from Utility Grid Smax (from grid) Max. Apparent Power from Utility Grid UAC,r Nominal Output Voltage fAC,r Nominal AC Grid Frequency IAC,max(to grid) Max. AC Current Output to Utility Grid IAC,max(from grid) Max. AC Current From Utility Grid P.F. Power Factor Sr Back-up Nominal apparent power Smax Max. Output Apparent Power (VA) Max. Output Apparent Power without Grid IAC,max Max. Output Current UAC,r Nominal Output Voltage fAC,r Nominal Output Frequency Toperating Operating Temperature Range IDC,max Max. Input Current UDC Input Voltage UDC,r DC Power Supply UAC Power Supply/AC Power Supply UAC,r Power Supply/Input Voltage Range Toperating Operating Temperature Range Pmax Max Output Power PRF TX Power PD Power Consumption PAC,r Power Consumption F (Hz) Frequency ISC PV Max. Input Short Circuit Current Udcmin-Udcmax Range of input Operating Voltage UAC,rang(L-N) Power Supply Input Voltage Usys,max Max System Voltage Haltitude,max Max. Operating Altitude PF Power Factor THDi Total Harmonic Distortion of Current THDv Total Harmonic Distortion of Voltage C&I Commercial & Industrial SEMS Smart Energy Management System MPPT Maximum Power Point Tracking PID Potential-Induced Degradation Voc Open-Circuit Voltage Anti PID Anti-PID PID Recovery PID Recovery PLC Power-line Communication Modbus TCP/IP Modbus Transmission Control / Internet Protocol Modbus RTU Modbus Remote Terminal Unit SCR Short-Circuit Ratio UPS Uninterruptible Power Supply ECO mode Economical Mode TOU Time of Use ESS Energy Storage System PCS Power Conversion System SPD Surge Protection Device DRED Demand Response Enabling Device RCR Ripple Control Receiver AFCI AFCI GFCI Ground Fault Circuit Interrupter RCMU Residual Current Monitoring Unit FRT Fault Ride Through HVRT High Voltage Ride Through LVRT Low Voltage Ride Through EMS Energy Management System BMS Battery Management System BMU Battery Measure Unit BCU Battery Control Unit SOC State of Charge SOH State of Health SOE State Of Energy SOP State Of Power SOF State Of Function SOS State Of Safety DOD Depth of discharge 12.3. Term Explanation Overvoltage category definition Category I: Applies to equipment connected to a circuit where measures have been taken to reduce transient overvoltage to a low level. Category II: Applies to equipment not permanently connected to the installation. Examples are appliances, portables tools and other plug-connected equipment. Category III: Applies to a fixed equipment downstream, including the main distribution board. Examples are switchgear and other equipment in an industrial installation. Category IV: Applies to equipment permanently connected at the origin of an installation (upstream of the main distribution board). Examples are electricity meters, primary over-current protection equipment and other equipment connected directly to outdoor open lines. Moisture location category definition Environmental Level Parameters 3K3 4K2 4K4H Moisture Parameters 0~+40℃ -33~+40℃ -33~+40℃ Temperature Range 15% - 85% 15% - 100% 4% - 100% Environment category definition Outdoor: Ambient Temperature: -25~+60℃, applied to Pollution Degree 3 environment. Indoor Unconditioned: Ambient Temperature: -25~+40℃, applied to Pollution Degree 3 environment. Indoor conditioned: Ambient Temperature: 0~+40℃, applied to Pollution Degree 2 environment. Pollution degree definition Contamination Class I: No contamination or only dry, non-conductive contamination; Pollution Degree II: Normally only non-conductive pollution occurs. Occasionally, however, a temporary conductivity caused by condensation must be expected. Pollution Degree III: Conductive pollution occurs, or dry. non-conductive pollution occurs, which becomes conductive due to condensation, which is expected. Pollution Degree IV: Persistent conductive pollution occurs, for example, the pollution caused by conductive dust, rain or snow. GoodWe official website GoodWe Technologies Co., Ltd. No. 90 Zijin Rd., New District, Suzhou, 215011, China T: 400-998-1212 www.goodwe.com [email protected] Local Contact ">
Download
Advertisement
Key features
Converts DC power from PV modules to AC power
Suitable for both plug and play and hardwired PV systems
Bluetooth and WiFi connectivity for monitoring and control
Power derating to comply with local regulations and ensure safe operation
Connects to SEMS+ App via WiFi to realize remote monitoring and control of inverters and power stations
Frequently asked questions
The open-circuit voltage must not exceed 60V.
PV modules used with inverters must comply with IEC 61730 Class A standard.
The inverter supports Bluetooth 5.0 and 2.4G WiFi.