EH 9 Use and operation
7.4
Starting up
Connecting the machine to the power supply
The machine may only be connected to AC single phase, connection values see chapter
Technical Data
.
NOTICE
Electrical voltage.
Incorrect voltage can cause damage on the machine.
f
Check if the voltage of the current source corresponds with the information of the machine, see chapter
Technical Data
.
WARNING
Electrical voltage.
Injuries from electrocution.
f Check power cable and extension cable for signs of damage.
f
Only use extension cables for which grounded conductors are connected to the plug and the coupling (only for machines of class rating I).
1. If required, connect the machine to a permitted extension cable.
Note:
See chapter
Technical data
for the permitted lengths and cross-section areas of extension cables.
2. Insert the plug into the plug receptacle.
35
advertisement
Related manuals
advertisement
Table of contents
- 6 Means of representation for this operator's manual
- 7 Wacker Neuson representative
- 7 Described machine types
- 8 Identification of the machine
- 9 Principle
- 12 Qualification of the operating personnel
- 13 Protective gear
- 14 Transport
- 14 Operating safety
- 16 Safety during the operation of hand machines
- 17 Safety during the operation of electric appliances
- 18 Maintenance
- 20 Safety and information labels
- 22 Application
- 22 Functionality
- 23 Components and operator's controls
- 26 Prior to starting the machine
- 27 Adjusting the machine
- 27 Speed/rpm
- 28 Supplementary handle
- 30 Changing tools
- 30 General instructions
- 31 Tool holder SDS-max
- 34 Tool holder for tool with hexagonal bolt
- 35 Starting up
- 36 Decomissioning
- 37 Maintenance schedule
- 38 Maintenance work
- 38 Cleaning the machine
- 39 Lubricating the crank mechanism
- 40 Checking the tool holder for wear
- 42 10.1 Disposal of waste electrical and electronic equipment
- 44 12.1 EH 9 BL/BLM
- 46 12.2 EH 9 BL/BLM
- 47 12.3 Extension cable