7 Operation
7.3
Installation
Set up the generator so it is protected from rain, snow or other forms of moisture.
The ground must be solid and level in order to prevent slipping or displacement.
Do not direct the engine exhaust to an area with people.
Both the work area as well as the components must be protected from all forms of moisture.
7.4
Current depreciation
Generators run differently due to altitude and temperature differences.
Unmodified internal combustion engines have reduced performance at high altitudes due to the lower air pressure. This means less performance and therefore a reduced power exploitation. As soon as temperatures increase, an engine runs less economically and electrical components have more resistance.
For every 500 meters above high altitudes of 1000 meters above sea level, the performance of the generator is reduced by 3%. For outside temperatures above
40 degrees Celsius, the generator performance is reduced by 3% for every additional 5 degrees. The tables shown help with the high altitude and outside temperature performance devaluation. In order to determine the true generator performance, it may be necessary to consider both the high altitude and temperature devaluation factors.
24
100_0402_op_0003.fm
7 Operation
Outside temperature
°C
45
50
55
60
High altitude m
1500
2000
2500
3000
3500
4000
Devaluation
3 %
6 %
9 %
12 %
Devaluation
3 %
6 %
9 %
12 %
15 %
18 %
Factor
0.97
0.94
0.91
0.88
Factor
0.97
0.94
0.91
0.88
0.85
0.82
100_0402_op_0003.fm
25
advertisement
Related manuals
advertisement
Table of contents
- 6 Means of representation of this operator's manual
- 7 Wacker Neuson Contact partner
- 7 Described equipment types
- 8 Product identification of the equipment
- 9 Safety information in this operator's manual
- 10 Description and purpose of the machine
- 11 Operational safety
- 12 Operator qualifications
- 15 Safety when using combustion engines
- 16 Service safety
- 22 Prepare the machine for first-time application
- 23 Power requirements
- 24 Installation
- 24 Current depreciation
- 26 Ground
- 26 Heavy duty operation
- 27 Use of extension cables
- 29 Control Panel
- 31 Before starting
- 32 7.10 Starting
- 32 7.11 Stopping
- 33 7.12 Emergency stop procedure
- 34 Period maintenance schedule
- 35 Engine oil
- 36 Air cleaner maintenance
- 37 Spark plug
- 38 Engine speed
- 39 Long-term storage
- 41 10.1 Disposal of old electrical and electronic equipment
- 42 11.1 GV
- 44 11.2 GV
- 46 11.3 Combustion engine
- 49 13.1 GV 7000A - Wiring diagram
- 50 13.2 GV 7003A - Wiring diagram