8 Maintenance
8.2
Engine oil
See blueprint: wc_gr000022
1. Drain the engine oil when the engine is warm.
2. Remove the sealing plug
(a)
and the drain plug
(b)
to drain the oil.
Comment:
For environmental reasons, a bin should be placed under machine to catch the fluid and a waterproof sheet should also be placed under the machine to protect the ground. The fluid must be dispose of according to the relevant regulations.
3. Reinsert the drain plug.
4. Fill the engine crankcase with the recommended engine oil up to the oil level marking
(c)
. For the oil quantity and type, see
Technical Data
.
5. Screw the sealing plug back in.
wc_gr000022
100_0402_mt_0001.fm
35
advertisement
Related manuals
advertisement
Table of contents
- 6 Means of representation of this operator's manual
- 7 Wacker Neuson Contact partner
- 7 Described equipment types
- 8 Product identification of the equipment
- 9 Safety information in this operator's manual
- 10 Description and purpose of the machine
- 11 Operational safety
- 12 Operator qualifications
- 15 Safety when using combustion engines
- 16 Service safety
- 22 Prepare the machine for first-time application
- 23 Power requirements
- 24 Installation
- 24 Current depreciation
- 26 Ground
- 26 Heavy duty operation
- 27 Use of extension cables
- 29 Control Panel
- 31 Before starting
- 32 7.10 Starting
- 32 7.11 Stopping
- 33 7.12 Emergency stop procedure
- 34 Period maintenance schedule
- 35 Engine oil
- 36 Air cleaner maintenance
- 37 Spark plug
- 38 Engine speed
- 39 Long-term storage
- 41 10.1 Disposal of old electrical and electronic equipment
- 42 11.1 GV
- 44 11.2 GV
- 46 11.3 Combustion engine
- 49 13.1 GV 7000A - Wiring diagram
- 50 13.2 GV 7003A - Wiring diagram