Averaging, Error Processing, Spike Correction and Statistics. MICRO-EPSILON optoNCDT 2300


Add to my manuals
202 Pages

advertisement

Averaging, Error Processing, Spike Correction and Statistics. MICRO-EPSILON optoNCDT 2300 | Manualzz

Control Menu, Set Sensor Parameter

Grey shaded fields require a selection.

Value

Dark-bordered fields require you to specify a value.

optoNCDT 2300

7.4.4

Averaging of measurement value

Statistics

Averaging, Error Processing, Spike Correction and Statistics

Video averaging

Error processing

Spike correction

No averaging /

Recursive 2 / 4 / 8

Moving 2 / 3 / 4

Median 3

The video averaging is effected before the calculation of the displacement or thickness. Recommended for very small peaks respectively to receive more valid data.

No averaging

Moving N values

2 / 4 / 8 ... 128

Value Indication of averaging mode. The

Recursive N values

2 ... 32768

Value averaging number N indicates the number

Median N values

3 / 5 / 7 / 9

Value of consecutive measurement values to be averaged in the sensor.

Error output, no measurement value

Hold last value

0 ... 1024

Sensor emits error value.

Value If no valid measurement value is determined, the last valid value can be hold for a certain period, that is, output repeatedly.

The last valid value is kept indefinitely at

„0“.

No

Yes

Evaluation length

1 - 10

Max. tolerance range (mm)

0 - 100

2 / 4 / 8 / 16 ... 16384

Number of corrected value

1 - 100

Value This filter removes individual very high spikes from a relatively constant course of measurement value.

Value

Smaller spikes are preserved.

Value

Beyond a certain number of measurement values the statistical values minimum, maximum and peak-to-peak are determined and output.