Pan Characteristics. AMX AXB-CAM

Add to My manuals
52 Pages

advertisement

Pan Characteristics. AMX AXB-CAM | Manualzz

Installation

Lens Control DB-15 HD Connector Pinouts for Servomotor Mode

Pin

7

8

5

6

3

4

1

2

9

10

11

12

13

14

15

PosiTrack DB-15 HD connector functions

+12 VDC

GND

Zoom-drive

Focus-drive

Iris-drive

Zoom-speed/position

Focus-speed/position

Iris-local/auto

Iris-speed/position

VREF-A (+7.5V)

VREF-B (+2.5 V)

POT-REF+ (+5 VDC)

POT-REF- (GND)

Zoom-wiper (0-5 VDC)

Focus-wiper (0-5 VDC)

Direction

Output

Output

Output

Output

Output

Output

Output

Output

Output

Input

Input

Output

Output

Input

Input

Lens function

Motor Power (see following note)

Lens common

Zoom motor

Focus motor

Iris motor

Zoom-positional/speed mode

Focus-positional/speed mode

Iris-local/auto select

Iris-positional/speed mode

VREF-A (+7.5 V). The reference voltage must be

present to operate correctly in servomotor mode.

VREF-B (+2.5 V). The reference voltage must be present to operate correctly in servomotor mode.

POT-high side

POT-low side

Zoom-POT wiper

Focus-POT wiper

Pin 1 is not required if the lens is powered independently. Pins 12-15 are required for

Speed mode but are not required for Positional mode.

This feature is controlled by the PANJA/CAM switch on the connector panel.

Servomotor driven outputs are intended to drive servo-type motors only. The outputs have very low current (milliampere range) capability. DO NOT attempt to drive conventional motors with these outputs or you may damage the output drivers. If you are not sure about the motor type, refer to the

Specifications section on page 1for more information.

Pan Characteristics

The pan drive has a maximum pan range of ± 174° (348° total). The maximum pan rate is 35° per second. Pan travel is capable of being limited to a restricted range around the center of pan travel by software limits adjustable by the programmer/end user. Pan limits refer to the horizontal range of motion available to the PosiTrack unit. These limits are set via the Axcess program. The center position marks the center of the range.

If you are using firmware version 1.01, do not set a preset at the same location as a limit stop.

Setting the adjustable pan-limit stops

The Central Controller should be programmed by an AMX Axcess programmer before beginning.

Refer to the Specifications section on page 1 for more information on programming devices. To set

the adjustable pan-limit stops:

AXB-PT10/30 PosiTrack Camera Controllers 23

advertisement

Related manuals

advertisement