7. Alarm pages
A 31/01 17:35 1/7
CONVEYOR FAULT
Switch off.
Remove the jammed part.
A 31/01 17:35 2/7
CONVEYOR FLT1
Change to N
°2.
The left and right arrow buttons are used to scroll through the alarm list.
Alarm log
NOTE:
Log principles
Alarms are stored one after another. Once the log is full, new alarms overwrite the oldest alarms.
In this way each alarm event (appearance, acknowledgment,
disappearance see section Appearance types, Page 20 ) is recorded and
time-stamped.
In order for an alarm page to be stored in the log, the store option must be enabled for the page
( see chapter C, section Page appearance types, Page 30 ).
The following functions can be executed:
- initiated by the PLC:
- print log
- clear log
- initiated by the operator:
- view log
- print log
- clear log
B
Magelis
XBT ref.
N200
Note
No alarm management
B - 41
7. Alarm pages
NOTE: On XBT N display units, the log is not saved (when the display unit is switched off, the log is cleared).
On XBT R display units, the retention period for the log is limited to twelve hours. Beyond that time there is a possibility that the log will be cleared.
View the log
The alarm log can be viewed from the “MENU” system page ( see section
Principle of system pages, Page 17 ).
LIST OF ALARMS
ALARMS LOG
Once inside the log, you can browse through the various alarms (
see section Viewing alarms, Page 40 ).
Clear the log
Clearing initiated by the operator:
In the “MENU” system page select ALARMS LOG and then in the following page select CLEAR.
Clearing initiated by the PLC:
The log is cleared by means of the log reset command word in the dialog table (
see chapter C, section Clear log/Advanced functions, Page 78
).
XBT ref.
N400/N401/N410
NU400
B - 42
Note
For display units in “input” mode only
Magelis