9. Setting the display unit parameters
Line parameters
This system page is used to display information relating to the communication protocol, such as the speed or parity.
Error counters also appear on this page, and their meaning is as follows:
Counter
1
2
3
4
5
6
7
8
9
Modbus
Number of responses received without a
CRC error by the master
Number of messages received with a CRC error by the master
Number of exception responses received by the master
Number of broadcast requests sent by the master
Number of requests still awaiting a response
Number of ‘PLC not ready’ responses received by the master
Number of incorrect characters received
Number of requests correctly executed
/
Modbus Slave
Number of messages received by the terminal, whether or not they are relevant
Number of messages received with a CRC error
Number of error messages returned by the terminal
Number of correct messages received by the terminal
Number of broadcast messages received by the terminal
Uni-Telway
Number of messages sent and not acknowledged
Number of messages sent and refused
Number of messages received and not acknowledged
Number of messages sent and refused
Number of messages sent correctly
Always at 0
Number of messages received correctly
Number of messages not processed because the terminal was not ready
Number of messages received with parity errors, format errors, etc.
Number of correct messages received and processed by the terminal
Number of emitting frames sent
Number of receiving frames received
/
B
Magelis
XBT ref.
N200
Note
No access to the "System" system page
B - 49
9. Setting the display unit parameters
B - 50
XBT ref.
/
Note
/
Magelis
Magelis
Chapter C
Detailed description of the XBT L100• program
C
C - 1
C - 2 Magelis
Contents
Software functions for creating an application:
1. Introduction: Creating Magelis applications ______________________________ 5
2. Presentation of the XBT L100• program ________________________________ 6
Launching the program in Windows __________________________________ 6
Presentation of the software ________________________________________ 6
3. Using XBT L100• software _________________________________________ 13
Creating a new application ________________________________________ 13
Application pages _______________________________________________ 27
Alarm pages ____________________________________________________ 29
System pages __________________________________________________ 31
Alias __________________________________________________________ 32
Navigation links _________________________________________________ 33
Text __________________________________________________________ 33
Circular text ____________________________________________________ 41
Alphanumeric variable fields _______________________________________ 43
Configuring the function keys ______________________________________ 49
Functional links _________________________________________________ 51
4. Dialog table _____________________________________________________ 53
Introduction: Concepts ____________________________________________ 53
Exchanged data _________________________________________________ 54
Configuring the dialog table ________________________________________ 56
5. Simulation ______________________________________________________ 58
Introduction ____________________________________________________ 58
Display-unit simulation window _____________________________________ 58
PLC simulation window ___________________________________________ 59
6. Transferring an application _________________________________________ 63
Connecting the display unit ________________________________________ 63
Starting up the display unit ________________________________________ 63
Importing an application ___________________________________________ 63
Exporting an application __________________________________________ 64
7. Description of dialog-table words ____________________________________ 65
Detailed description ______________________________________________ 67
C
Magelis C - 3
Contents
C - 4 Magelis
.
C
1. Introduction: Creating Magelis applications
NOTE:
A Magelis application consists of the entire dialog between the operator and the automated process. In its entirety, this should take account of:
- The criteria relating to the control system:
- production monitoring
- preventive maintenance
- corrective maintenance
- process control
- The user criteria:
- user interface
- level of intervention
- The criteria for creating the actual dialog application:
- programming
- debugging
- upgrading
These constraints mean that it is necessary to structure your application. An application should consist of a set of pages, which can be arranged in a tree structure as shown in the figure below:
C
-----
1 - Display
2 - Control
3 - Maintenance
Display
-----
SPEED M/min
QUANTITY Amt/hr
Control
----
Conveyor
Hopper
Maintenance
-----
OP. DURATIONS
SYSTEM PAGES
OPERATING DURATION
----
Machine hr
Guard hr
Magelis
XBT ref.
/
Note
/
C - 5
Downloaden
Advertentie