Load Schedule View
The Load Schedule View allows you to add loads, also called controlled circuits, to your D3 Pro system. Loads are connected to Crestron's CLX and CLW control modules, which support all standard fixtures and load types, as shown in the following table:
Control Module
CLX-DIM
CLX-4HSW4
CLX-1DELV4
Load Support
Incandescent (Dim, Non-Dim)
Magnetic Low Voltage (Dim, Non-Dim)
Electronic Low Voltage (Dim, Non-Dim)
Neon/Cold-Cathode (Dim, Non-Dim)
Fluorescent Dim (2-Wire) (Dim, Non-Dim)
Fluorescent Non-Dim
Switched
Switched
Incandescent (Non-Dim only)
Magnetic Low Voltage (Non-Dim only)
Electronic Low Voltage (Non-Dim only)
Neon/Cold-Cathode (Non-Dim only)
Fluorescent Dim (2-Wire) (Non-Dim only)
Fluorescent Non-Dim
H.I.D
Electronic Low Voltage (Dim, Non-Dim)
Incandescent (Dim, Non-Dim)
CLW-DIM
CLW-DIMS
CLW-SW
CLW-SWS
Incandescent (Dim only)
Magnetic Low Voltage (Dim only)
Switched, i.e., general purpose fan (consult CLW-SW/S documentation to verify the appropriateness of a particular
switched load)
Incandescent (Non-Dim only)
Magnetic Low Voltage (Non-Dim only)
Electronic Low Voltage (Non-Dim only)
Neon/Cold-Cathode (Non-Dim only)
Fluorescent. Dim (2-Wire) (Non-Dim only)
Fluorescent Non-Dim
H.I.D
The Load Schedule toolbox provides two fixture libraries: Global and Project. Each library contains 16 generic fixture categories.
When adding loads to your load schedule, you can select one of the 16 generic fixtures from either library, or you can create your own user-defined fixtures that appear as sub-categories of the generic categories. If you add a user-defined fixture to the Global Library, that fixture will be available to any D3 Pro project you design on your computer. If you add a user-defined fixture to the Project Library, that fixture is available only in the current project.
Reference Guide – DOC. 5998a Crestron D3 Pro™ • 21
22 • Crestron D3 Pro™
You can add a generic fixture in a number of ways:
• Drag the generic fixture from either library in the Fixtures toolbox to a room.
• If you select a room in the system tree, you can also drag the fixture from the toolbox onto the Load Schedule area in the center of the screen.
• To add multiple fixtures, hold down the Shift key while you drag the fixture from the toolbox to a room. Then select the number of fixtures you want to add. You can also hold down the Shift key, right-click a room, point to New, and select the fixture. Then select the amount.
• You can right-click a room, point to New, and then select a generic fixture from the submenu. A generic fixture appears as one of the 16 main fixture categories.
To add a user-defined fixture:
• Drag the fixture from the Global or Project library to a room, just as described above. User-defined fixtures appear as sub-categories of a generic fixture.
• You can right-click a room, point to New, and then point to the generic fixture category. Select the user-defined fixture from the submenu.
• Use the methods described above to add multiple user-defined fixtures.
Reference Guide – DOC. 5998a
Crestron D3 Pro ™ Software
You can right-click any fixture you have added to cut, copy and paste, rename or delete the fixture. You can also activate the Trace tool (see page 83).
Load Type
The table below lists the load types and corresponding generic categories:
Default Generic Category Description
Lighting
Incandescent
Accents
Bath/Vanity
Ceiling Light
Chandeliers
Downlights
Outdoor Lights
Pendants
Sconces
Table Lamps
Other
Neon/Cold Cathode Bent Glass
Lighting
Ceiling Fan
Ceiling Fan
Multi-speed ceiling fan motor
Magnetic Low Voltage
Cove Lights
Lighting
3-Wire Motor Drapes
3-wire, 2-direction motor
Switched
Exhaust Fan
Pump
Any non-lighting load that can be turned full on or off only
Fluorescent Non-Dim
Fluorescent Dim (2-Wire)
Electronic Low-Voltage
H.I.D.
Lighting
Non-dimmable fluorescent ballasts
Lighting
2-wire dimmable fluorescent ballasts
Lighting
Lighting
High Intensity Discharge
Reference Guide – DOC. 5998a Crestron D3 Pro™ • 23
advertisement
Related manuals
advertisement
Table of contents
- 5 D3 PRO
- 6 System Views
- 6 Interface View
- 6 Load Schedule View
- 6 Module and Enclosure Assignment View
- 6 Equipment View
- 7 Programming View
- 7 Finish View
- 7 System Requirements
- 7 File Structure
- 8 Import/Export Archive
- 8 Documentation
- 10 Live Update
- 11 Live Update Firmware
- 12 Set System Properties
- 15 Add Areas and Rooms
- 16 Interfaces View
- 18 Interface Properties
- 20 Engraving Options
- 25 Load Schedule View
- 28 Create a user-defined fixture
- 31 Controlled Circuit Properties
- 33 Advanced Lighting/Motor Properties
- 35 Module and Enclosure Assignment View
- 35 Module Assignment Wizard
- 38 Manual Assignment Mode
- 43 Equipment View
- 43 Auxiliary Devices Mode
- 44 Controlled Devices Mode
- 45 Device Properties
- 47 Remote System Definitions
- 49 Programming View
- 50 Actions and Events
- 50 Digital, Analog, and Serial Commands
- 52 User Interfaces
- 53 Button Models
- 59 Button Feedback
- 61 Button Groups
- 62 Synchronize Events
- 62 Assigning Actions to Events
- 65 Device Commands
- 67 Copy/Paste Steps and Button Logic
- 69 Learnable Lighting
- 70 Adjusting Lighting Levels in Real Time
- 72 Conditional Statements
- 76 Global Variables
- 78 Global Presets
- 80 D3 Pro Scheduler
- 85 Vacation Scheduler
- 87 Trace Tool
- 88 Finish View
- 90 Sync Learned Lighting
- 90 Set Network IDs
- 96 Build System
- 97 Upload System
- 102 Merchandise Returns / Repair Service
- 102 CRESTRON Limited Warranty