Setup

3. Setup

AC Power

AC Plug

The Legend™ 412 Series has an auto-ranging power supply that works with an input voltage range of 100~240 VAC, 50/60 Hz.

Make sure that you are connecting this product to the proper voltage. To determine the power requirements for the Legend™ 412 Series, refer to the specification label affixed to the product or the specifications in this manual.

Always connect this product to a protected circuit with an appropriate electrical ground to avoid the risk of electrocution or fire.

The listed current rating indicates the maximum current draw during normal operation. For more information, download Sizing the Circuit Breakers from www.chauvetpro.com

.

Never connect this product to a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel serves only as a 0 to 100% switch.

The Legend™ 412 Series should be used with a power input cord terminated with an IEC connector on one end and an Edison plug on the other end (U.S. market). Use the table below to wire a new plug if needed.

Connection Wire (U.S.) Wire (Europe) Screw Color

AC Live

AC Neutral

Black

White

Brown

Blue

Yellow or Brass

Silver

Fuse Replacement

AC Ground Green/Yellow Green/Yellow Green

Make sure to disconnect the product’s power cord before replacing a blown fuse, and always replace it with a fuse of the same type and rating.

This product uses a T 3.15 A, 250 V fuse.

1. Disconnect the product from the power outlet.

2. Using a flat head screwdriver, wedge the tip into the slot of the fuse holder.

3. Pry the safety cap out of the housing to pull out the installed fuse.

4. Remove the blown fuse from the safety cap and replace with a fuse of the exact same type and rating (T 3.15 A, 250 V).

5. Insert the fuse holder back in place and reconnect power.

Spare fusel

(inside safety cap)

Installed fuse

(held by plastic clip)

Safety cap

This product ships with a spare fuse inside the safety cap, as shown above.

-8- Legend™ 412 Series User Manual Rev. 5

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals