electrical wiring

Electrical wiring North American model in.xe™

Main electrical box GFCI panel in.xe

Warning!

"For units for use in other than single-family dwellings, a clearly labeled emergency switch shall be provided as part of the installation. The switch shall be readily accessible to the occupants and shall be installed at least 5 feet (1.52 m) away, adjacent to, and within sight of the unit".

-----

This product must always be connected to a circuit protected by a ground fault interrupter.

-----

Proper wiring of the electrical service box, GFCI and in.xe™ terminal block is essential!

Check your electrical code for local regulations. Only copper wire should be used, never aluminum.

Disposal of the product

The appliance (or the product) must be disposed of separately in accordance with the local waste disposal legislation in force.

14

in.xe

Electrical wiring

North American or ce model in.xe™ electrical wiring bonding lug

To install the wiring for the in.xe™ spa control, you'll need a Phillips screwdriver and a flat screwdriver.

Loosen the 2 screws of the Spa

Pack door and open it.

Remove 5 1/2" (142 mm) of cable insulation.

Strip away 1" (25 mm) of each wire insulation.

Pull the cable through the cutout of the box and secure it with a strain relief (1" NPT strain relief; hole diameter: 1.335").

(For CE use an IEC certified plastic bushing that will maintain the IPX5 rating.)

Make sure that only the uncut sheathing is clamped at this opening.

Push the color-coded wires into the terminals as indicated on the sticker and use the flat screwdriver to tighten the screws on the terminals.

After making sure wire connections are secure, push them back into the box and close the door. Tighten the 2 screws of the Spa Pack door.

Connect the bonding conductor to the bonding lug on the front of the in.xe™ Spa Pack

(a grounded electrode conductor shall be used to connect the equipment grounding conductors).