Decompression Stop Information
If you exceed the no-stop limits, the Monitor 3 will replace the no-stop time with the deepest (first) decompression stop depth (in feet) along with the amount of decompression time (in minutes) at that depth. When a decompression stop has been completed, the next shallower decompression stop is displayed, along with its required stop time. When all decompression stops are completed, the DECO arrow disappears and the NO STOP arrow reappears.
WARNING: If you ascend shallower than the required decompression stop depth, the DECO arrow will start flashing and an acoustic alarm will sound. Due to the formation of microbubbles, decompression obligation can increase greatly if a decompression stop is ignored. When the surface is reached during the decompression alarm, the
DECO arrow continues to flash to point out the risk of a decompression accident. If you do not descend immediately to the required stop depth, the Monitor 3 will enter SOS Mode. Any decompression violation longer than one minute is entered in the computers logbook. Ignoring decompression stops may lead to serious injury or death due to decompression sickness.
Section 2: Diving with the Monitor 3 Air
Decompression stop information display
23
advertisement
Related manuals
advertisement
Table of contents
- 9 What is a “Dive Computer
- 9 Definition of Compartments
- 9 Multi-Level Diving
- 10 Diving Responsibly
- 11 Features of the Monitor 3 Air
- 11 The Computer Screen
- 11 The Electrical Contacts
- 13 The Transmitter
- 15 Attaching the Transmitter to Your Regulator
- 16 Pairing the Wrist Unit to the Transmitter
- 19 Using the Monitor 3 Air Without the Transmitter
- 19 Checking the Battery Power
- 21 Preparation for the Dive
- 23 Functions During the Dive
- 23 Current Depth
- 24 Dive time
- 24 Maximum depth
- 25 Ascent Rate
- 26 No-Stop Time
- 27 Cylinder Pressure
- 27 Antenna Symbol
- 28 Graphic Air Time Remaining
- 28 Digital Air Time Remaining
- 29 High Air Consumption Warning
- 30 Decompression Stop Information
- 31 Total Ascent Time
- 31 SOS Mode
- 32 Functions at the Surface
- 32 Upon surfacing
- 32 Surface Mode
- 32 Surface mode icon
- 33 Wait-to-fly Time
- 34 Desaturation Time
- 34 Surface Interval Time
- 35 Microbubble Warning