advertisement
![Initial Operation. Parkside IAN 104473 | Manualzz Initial Operation. Parkside IAN 104473 | Manualzz](http://s1.manualzz.com/store/data/004452666_1-065c44c24773deab514d46e4be652a6b-360x466.png)
GB ter.
• Water that has passed through a backflow preventer is classified as undrinkable.
• High-pressure hoses, fittings and couplings are important for machine safety. Use only high-pressure hoses, fittings and couplings recommended by the manufacturer.
• To ensure machine safety, use only original replacement parts from the manufacturer or replacement parts authorised by the manufacturer.
Electrical safety:
Caution: to avoid accidents and injuries from electric shocks:
• The plug and socket of an extension cable must be water-tight!
Unsuitable extension cables can be dangerous as people can be harmed by an electric shock!
• Before each use, check the equipment, cable and plug for damage.
• If the power cable for this equipment is damaged, it must be replaced by the manufacturer, a customer service agent of the same or a similarly qualified person in order to prevent hazards.
• Do not pull the plug from the socket by the cable. Protect the cable from heat, oil and sharp edges.
• Do not carry or fix the equipment by the cable.
• Use only extension cables that are protected from spray water and designed for outdoor use. Always fully unroll a cable drum before use. Check the cable for damage.
• Before any work on the equipment, during work breaks and in the case of non-use, remove the plug from the socket.
• The cross-section of the power supply cable must not be less than
2 x 2,5 mm².
• Wear sturdy footwear to protect against electric shock.
Initial Operation
• Protect the electric plug connections against moisture.
• If there is a risk of flooding, fix the plug connections in an area that is safe from flooding.
• Ensure that the mains voltage matches the specifications on the rating plate.
• The electrical installation shall be according to national wiring rules.
• Connection to the mains must be carried out by an experienced electrician and meet the requirements of
IEC 60364-1.
• The device must only be connected to a mains socket via a residual-current circuit breaker (RCD) with a rated leakage current of not more than 30 mA.
Fuse: at least 13 ampere.
In keeping with current regulations a pressure washer must never be operated off the drinking water mains supply without a controllable backflow preventer. A suitable backflow preventer in conformity with EN 12729 type BA must be used.
Water that has passed through a backflow preventer is classified as undrinkable.
A backflow preventer is available from specialist retailers.
20
advertisement
Related manuals
advertisement
Table of contents
- 4 Einleitung
- 4 Verwendung
- 5 Allgemeine Beschreibung
- 5 Lieferumfang
- 5 Übersicht
- 5 Funktionsbeschreibung
- 5 Technische Daten
- 6 Sicherheitshinweise
- 6 Symbole auf dem Gerät
- 6 Bildzeichen in der Anleitung
- 6 Allgemeine Sicherheitshinweise
- 8 Inbetriebnahme
- 9 Aufstellen
- 9 Netzanschluss
- 9 Betrieb
- 10 Betrieb unterbrechen
- 10 Betrieb beenden
- 11 Räder fixieren
- 11 Wartung und Reinigung
- 11 Reinigung
- 11 Wartung
- 12 Lagerung
- 12 Entsorgung/Umweltschutz
- 12 Garantie
- 13 Reparatur-Service
- 14 Ersatzteile/Zubehör
- 14 Service-Center
- 14 Importeur
- 15 Fehlersuche
- 28 erklärung
- 29 Explosionszeichnung
- 16 Introduction
- 16 Intendend purpose
- 17 General Description
- 17 Extent of the Delivery
- 17 Overview
- 17 Functional description
- 17 Technical data
- 18 Notes on Safety
- 18 Explanation of symbols
- 18 Symbols in the manual
- 18 General notes on safety
- 20 Initial Operation
- 21 Setting up
- 21 Mains connection
- 21 Operation
- 22 Interrupting operation
- 22 Ending operation
- 22 Using detergents
- 22 Fixing the Wheels
- 23 Cleaning and Maintenance
- 23 Cleaning
- 23 Maintenance
- 23 Storage
- 23 Protection
- 24 Guarantee
- 25 Repair Service
- 25 Service-Center
- 25 Importer
- 26 Spare parts/Accessories
- 27 Trouble shooting
- 28 EC declaration of conformity
- 29 Exploded Drawing