SECURING THE LOADER. Wacker Neuson WL50
إعلان
إعلان
9
Securing the loader
SECURING THE LOADER
The following instructions apply to stopping and parking the loader after daily operation, transporting the loader and to all servicing, inspection and repair work.
•
Place the loader on an even, dry surface that can support sufficient weight.
•
Lower the loader lift arms.
•
Engage the parking brake and stop the engine.
•
Switch off all electrical switches.
•
Relieve the pressure in all hydraulic circuits by cycling the controls after the engine has stopped.
•
Secure the loader with the wheel chock.
•
Clean dirt off the loader.
•
Perform a visual inspection to make sure there are no leaks:
- in the hydraulic system
- in the cooling system
- in the fuel system
•
Perform a visual inspection for damage to the loader, especially on the tires, attachments and locking mechanism for the attachments.
•
Fill the fuel reservoir and check the operating level of the other fluid reservoirs after the temperature has been reduced to a level that is comfortable to touch.
•
Secure the loader against unauthorized use:
- Remove the starting key
- Close the windows, doors, reservoir lid and engine enclosure.
139