E.g., if it is 10:30 pm now, the bar plotted directly above

-1 shows the reading recorded from 9 to 10 pm and

-6 shows the reading recorded earlier in the evening, between 4pm-5pm.

to view the UV / Barometer / Rainfall readings:

1. Press SELEct to navigate to the UV / Barometer /

Rainfall Area. will show next to the Area.

2. Press ModE to toggle between UVI / Barometer /

Rainfall readings. The corresponding icon will appear:

UVI BARoMEtER RAINFALL to select the measurement unit for the barometer or rainfall readings:

In the UV / Barometer / Rainfall Area, press UNIt to switch between:

• Barometer: Millimeters of mercury ( mmHg ), inches of mercury ( inHg ), millibars per hectopascal ( mb ).

• Rainfall: Millimeters ( mm ), inches ( in ), recorded for that hour.

NotE As the purpose of the bar graph is only to provide a quick comparison between the records of the past 24 hours, the vertical axis cannot convert from inches to mm.

Therefore, changing the measurement unit will have no effect on the bar graph display.

2. Press ModE repeatedly to select Barometric display.

3. Press and hold ModE to enter the altitude setting.

4. Press / to increase / decrease the setting value.

5. Press ModE to confirm the setting.

RAINFALL

to view the recorded rainfall of the current hour or last 24 hours:

1. Press SELEct to navigate to the UVI / Barometer /

Rainfall Area. will show next to the Area.

2. Press ModE repeatedly to select Rainfall display.

3. Press MAX / MIN repeatedly to toggle between current, past 24 hour rainfall.

BAckLIgHt

Press LIgHt to activate the backlight for 5 seconds.

RESEt

Press RESEt to return to the default settings.

SPEcIFIcAtIoNS

BASE StAtIoN

Dimensions

(L x W x H)

Weight

Battery

94 x 51 x 182.5 mm

(3.7 x 2.0 x 7.2 inches)

241 g (8.5 oz) without battery

3 x UM-3 (AA) 1.5V

UV INdEX

the UV index levels are as follows:

UV INdEX

0-2

3-5

6-7 dANgER LEVEL

Low

Moderate

High

8-10 Very high

11 and above Extremely high

IcoN to view the maximum UV reading:

1. Press SELEct to navigate to the UVI / Barometer /

Rainfall Area. will show next to the Area.

2. Press ModE repeatedly to select UV display.

3. Press MAX / MIN to toggle between current / MAX

UV index display.

The timestamp is displayed accordingly in the Clock

Area.

to clear maximum UV reading:

1. Press SELEct to navigate to the UVI / Barometer /

Rainfall Area. will show next to the Area.

2. Press ModE repeatedly to select UV display.

3. Press and hold MAX / MIN to clear the readings.

BARoMEtER

to set the altitude level compensation for the

Barometer readings:

1. Press SELEct to navigate to the UVI / Barometer /

Rainfall Area. will show next to the Area.

9

INdooR BARoMEtER

Barometer unit

Measuring range

Accuracy

Altitude setting

Weather display

Memory mb, inHg and mmHg

700 – 1050mb/hPa

+/- 10 mb/hPa

Sea level

User setting for compensation

Sunny, Partly Cloudy, Cloudy,

Rainy and Snowy

Historical data and bar chart for last 24hrs

INdooR tEMPERAtURE

Temp. unit

Displayed range

Operating range

Accuracy

Memory

°C / °F

-50°C to 70°C (-58°F to 158°F)

0°C to 50°C (32°F to 122°F)

0°C - 40°C: +/- 1°C (+/- 2.0°F)

40°C - 50°C: +/- 2°C (+/- 4.0°F)

Current, Min and Max temp.

Dew Point w/ Min and Max

INdooR RELAtIVE HUMIdItY

Displayed range

Operating range

2% to 98%

25% to 90%

Accuracy

Memory

25% - 40%: +/- 7%

40% - 80%: +/- 5%

80% - 90%: +/- 7%

Current, Min and Max

RAdIo-coNtRoLLEd / AtoMIc cLock

Synchronization

Clock display

Hour format

Calendar

Weekday in 5 languages

Auto or disabled

HH:MM:SS

12hr AM/PM or 24hr

DD/MM or MM/DD

(E, D, F, I, S, R)

REMotE WINd SENSoR UNIt

Dimensions

(L x W x H)

Weight

Wind speed unit

Speed accuracy

178 x 76 x 214 mm

(7 x 3 x 8.4 inches)

100 g (0.22 lbs) without battery m/s, kph, mph, knots

2 m/s ~ 10 m/s (+/- 3 m/s)

10 m/s ~ 56 m/s (+/- 10%)

Direction accuracy 16 positions

Transmission of wind speed signal

Approx. every 56 seconds

Memory

Battery

Max wind speed

2 x UM-3 (AA) 1.5V batteries

oUtdooR tEMPERAtURE / HUMIdItY UNIt

Dimensions

(L x W x H)

Weight

Humidity range

92 x 60 x 20 mm

(3.6 x 2.4 x 0.79 in)

62 g (2.22oz) without battery

5% to 95%

Humidity accuracy 25% - 40%: +/- 7%

40% - 80%: +/- 5%

80% - 90%: +/- 7%

Temp. unit °C / °F

-30°C to 60°C (-22°F to 140°F) Temperature outdoor range

Temperature accuracy

RF frequency

Range

-20°C to 0°C:

+/- 2.0°C (+/- 4.0°F)

0°C to 40°C:

+/- 1.0°C (+/- 2.0°F)

40°C to 50°C:

+/- 2.0°C (+/- 4.0°F)

50°C to 60°C:

+/- 3.0°C (+/- 6.0°F)

433MHz

Up to 100 meters (328 feet) with no obstructions

Approx. every 102 seconds Transmission

Channel no.

Batteries

3

2 x UM-4 (AAA) 1.5V

REMotE RAIN gAUgE

Dimensions

(L x W x H)

Weight

Rainfall unit

Range

Accuracy

Memory

Battery

114 x 114 x 145 mm

(4.5 x 4.5 x 5.7 inches)

241 g (0.54 lbs) without battery

Mm and in

0 mm – 9999 mm

< 15 mm: +/- 1 mm

15 mm to 9999 mm: +/- 7%

Past 24hrs, hourly from last memory reset

2 x UM-3 (AA) 1.5V

PREcAUtIoNS

• Do not subject the unit to excessive force, shock, dust, temperature or humidity.

• Do not cover the ventilation holes with any items such as newspapers, curtains etc.

• Do not immerse the unit in water. If you spill liquid over it, dry it immediately with a soft, lint-free cloth.

• Do not clean the unit with abrasive or corrosive materials.

• Do not tamper with the unit’s internal components.

This invalidates the warranty.

• Only use fresh batteries. Do not mix new and old batteries.

• Images shown in this manual may differ from the actual display.

• When disposing of this product, ensure it is collected separately for special treatment and not as household waste.

• Placement of this product on certain types of wood may result in damage to its finish for which Oregon

Scientific will not be responsible. Consult the furniture manufacturer's care instructions for information.

• The contents of this manual may not be reproduced without the permission of the manufacturer.

• Do not dispose old batteries as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.

• Please note that some units are equipped with a battery safety strip. Remove the strip from the battery compartment before first use.

NotE The technical specifications for this product and the contents of the user manual are subject to change without notice.

NotE Features and accessories will not be available in all countries. For more information, please contact your local retailer.

10

ABoUt oREgoN ScIENtIFIc

Visit our website (www.oregonscientific.com) to learn more about Oregon Scientific products. If you're in the US and would like to contact our Customer Care department directly, please visit: https://us.oregonscientific.com/ service/support.asp

For international inquiries, please visit: http:// us.oregonscientific.com/about/international.asp

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Key Features

  • Monitor temperature, humidity, wind speed and direction, rainfall, and UV index
  • Indoor and outdoor sensors for comprehensive weather monitoring
  • Accurate and reliable weather information
  • Easy-to-read LCD display with customizable settings
  • Wireless sensors for convenient placement

Related manuals

Frequently Answers and Questions

What are the dimensions of the Oregon Scientific WMR86A?
The manual does not provide the dimensions of the Oregon Scientific WMR86A.
What is the power source for the Oregon Scientific WMR86A?
The Oregon Scientific WMR86A is powered by batteries.
What is the range of the wireless sensors?
The manual does not provide the range of the wireless sensors.

advertisement

Table of contents