EVFU Default. Genicom P600, 5000 Series, GEK 00031B, GEK 00031B

Add to My manuals
314 Pages

advertisement

EVFU Default. Genicom P600, 5000 Series, GEK 00031B, GEK  00031B | Manualzz

EVFU Default

The default EVFU will be generated based on the current form length and lpi setting under the following conditions:

▪ When the printer is initialized

▪ When either the forms definition or lpi setting is changed

▪ When the start EVFU load escape sequence ESC ] is immediately followed by the end load sequence ESC \

▪ When the emulation is changed from P Series or Dataproducts, to

ANSI

The following chart shows how the default EVFU table is defined:

CHANNEL

1

2

3

4

5

6

7

8

9

10

11

12

DESCRIPTION

Top Margin (first line

Bottom Margin (last line)

Single Spacing

Double Spacing

Triple Spacing

Half Form

Quarter Form

Tenth Line

Bottom of Form (bottom margin)

Bottom of Form minus 1 line

Top of Form minus 1 line (last line this form)

Top of Form

Skip to Channel Command

ESC [ p1 ; p2 ! p GENVFU (VFU Channel Command): Commands vertical paper movement to the channel specified by the number formed by p1 and p2. Valid channel numbers are in the range 1- 12.

0;1 - selects channel 1

0;9 - selects channel 9

1;1 - selects channel 11

Channel 1 is always used for TOF; channel 12 is always used for vertical tab. When the channel number is greater than 12, the program defaults to channel 1. If the table has not been loaded and a channel command is received, it is ignored.

Decimal:

Hex:

BASIC:

27 91 <p1> ; <p2> ! 112

1B 5B <p1> 3B <p2> 21 70

CHR$(27);"[<p1>;<p2>!p";