GENERAL PRINTER OPTIONS DEFINITIONS

I/F Hardware Straps

H Bits

01-32

01

Function

Prime

If Enabled

High = Buffer Clear.

If Disabled

02

03

04

05-06

07

08

09

Interrupt

DEL

DEL

Reserved.

Underline character

PI Lead

ACK lead

On all Control Codes.

Does not cause an Interrupt.

Does not cause Prime.

Treated as CR.

Causes Interrupt.

Does not reflect

ONLINE/LOCAL status. 05 must be enabled.

Low = Buffer Clear.

Disabled on all Control Codes, except

LF, VT, FF, CR, DC1 and DC3.

Causes an Interrupt.

Causes Prime.

Printed.

Does not cause Interrupt.

Reflects ONLINE/LOCAL status.

10

11

12

13

14

15

16

17

18

19

Character conversion to space.

CR

FF

LF

VT

DC3

DC1

Busy

Busy/Demand per character.

Software control of

Busy.

Enabled. (See 41-48.)

Not decoded.

Not decoded.

Not decoded.

Not decoded.

Not decoded.

Not decoded.

Does not reflect ACK.

Enabled.

Disabled

Disabled.

Generate an Interrupt.

Generate an Interrupt.

Generate an Interrupt.

Generate an Interrupt.

Generate an Interrupt.

Generate an Interrupt.

Reflects ACK.

Disabled.

Enabled.

20

21

22

27

28

29

30

31

23

24

25

26

32

H Bits

33-64

33

Busy

Busy

Busy

ACK

ACK

Data leads

Busy is active

PI is active

PI

STB is active

SELECT is active

PO is active

FAULT is active

Function

Does not reflect

(ONLINE/LOCAL) FAULT/PO status.

Does not reflect (FAULT)

ONLINE/LOCAL status.

Does not reflect (PO)

ONLINE/LOCAL/PO status.

Does not reflect PO.

Does not reflect FAULT.

0-7 are active high.

High.

High.

Enabled.

High.

High.

High.

High.

If Enabled.

Reflects (ONLINE/LOCAL) FAULT/PO status.

Reflects (FAULT) ONLINE/LOCAL status.

Reflects (PO) ONLINE/LOCAL/PO status.

Reflects PO.

Reflects FAULT.

0-7 are active low.

Low.

Low.

Disabled.

Low.

Low.

Low.

Low.

If Disabled

34-35

36-37

38-40

41-48

49-64

Demand delay.

Set ACK delay from

Strobe.

Disabled.

Enabled.

34

Disable

Disable

Enable

Enable

36

Disable

35

Disable

Enable

Disable

Enable

37

Disable

Delay

None

1 µsec

2 µsec

3 µsec

Width

None

Set ACK Pulse

Width.

Disable

Enable

Enable

Enable

Disable

Enable

1 µsec

2 µsec

3 µsec

Reserved.

Used with strap 10 to select space character substitution. 41 corresponds with Bit 1 of the character code.