Specifications of Options and Peripheral Devices. YASKAWA Varispeed f7
Reklama
Reklama
Specifications of Options and Peripheral Devices
Specifications of Options and Peripheral Devices
The following options and peripheral devices can be used for the Inverter. Select them according to the application.
Table 9.4 Options and Peripheral Devices
Purpose
Protect Inverter wiring
Prevents burning when a Braking Resistor is used.
Contains switching surge
Isolates I/O signals
Improve the input power factor of the
Inverter
Name
MCCB or Ground
Fault Interrupter
*1
Magnetic
Contactor
Surge Absorber
Isolator
DC Reactor
AC Reactor
Input Noise Filter
Model (Code)
NF
SC series
DCR2
DGP
UZDA
UZBA
LNFD
FN
Descriptions
Always connect a breaker to the power supply line to protect Inverter wiring. Use a ground fault interrupter suitable for high frequencies.
Install to prevent the braking resistor from burning out when one is used. Always attach a surge absorber to the coil.
Absorbs surge from the magnetic contactor and control relays. Connect surge absorbers to all magnetic contactors and relays near the Inverter.
Isolates the I/O signals of the Inverter and is effective against inductive noise.
Used to improve the input power factor of the Inverter. All
Inverters of 22 kW or higher contain built-in DC reactors.
These are optional for Inverters of 18.5 kW or less. Install
DC and AC reactors for applications with a large power supply capacity (600 kVA or higher).
Reduces noise coming into the Inverter from the power supply line and to reduce noise flowing from the Inverter into the power supply line. Connect as close to the
Inverter as possible.
Power supply
Molded-case circuit breaker or ground fault interrupter
Magnetic contactor (MC)
AC reactor for power factor improvement
Zero phase reactor
Braking resistor
Reduce the affects of radio and control device noise
Finemet zerophase reactor to reduce radio noise
*2
F6045GB
(FIL001098)
F11080GB
(FIL001097)
Reduces noise from the line that sneaks into the Inverter input power system. Insert as close to the Inverter as possible.
Can be use on both the input side and output side.
Input noise filter
F200160BP
(300-001-041) Inverter
Enable stopping the machine in a set time
Operates the Inverter externally
Output Noise Filter
Braking Resistor
Braking Resistor
Unit
Braking Unit
VS Operator
(small plastic
Operator)
VS Operator
(Standard steelplate Operator)
LF
ERF-150WJ
(R00
LKEB
CDBR
JVOP-95•
(73041-0905X-
JVOP-96•
)
(75600-K 0)
(72600-R 0)
(73041-0906X-
)
)
Reduces noise generated by the Inverter. Connect as close to the Inverter as possible.
Consumes the regenerative motor energy with a resistor to reduce deceleration time (use rate: 3% ED).
Consumes the regenerative motor energy with a resistor to reduce deceleration time (use rate: 10% ED).
Used with a Braking Resistor Unit to reduce the deceleration time of the motor.
Allows frequency reference settings and ON/OFF operation control to be performed by analog references from a remote location (50 m max.).
Frequency counter specifications: 60/120 Hz, 90/180Hz
Allows frequency reference settings and ON/OFF operation control to be performed by analog references from a remote location (50 m max.).
Frequency counter specifications: 75 Hz, 150 Hz, 220 Hz
Varispeed F7
Ground
Output noise filter
Ground
DC reactor for power factor improvement
Zero phase reactor
Motor
Digital Operator
Connection Cable
1 m cable: (72616-
WV001)
3 m cable: (72616-
WV003)
Extension cable to use a Digital Operator remotely.
Cable length: 1 m or 3 m
Controls an Inverter system
Provides Inverter momentary power loss recovery time
VS System Module
Momentary Power
Loss Recovery
Unit
JGSM
Frequency Meter DCF-6A
Frequency Setter RV30YN20S (2 k Ω )
Frequency Setter
Knob
P00 0
(73600-P00
CM-3S
0)
A system controller that can be match to the automatic control system to produce an optimum system configuration.
Handles momentary power losses for the control power supply for models 11 kW or less (maintains power for
2 s).
Set/monitor frequencies and voltages externally.
Devices to set or monitor frequencies externally.
Output Voltmeter SCF-12NH
Measures the output voltage externally and designed for use with a PWM Inverter.
Correct frequency reference input, frequency meter, ammeter scales
Variable Resistor
Board for Frequency Reference
Frequency Meter
Scale Correction
Resistor
2 k Ω
20 k
(ETX003270)
Ω (ETX003120)
(RH000850)
Connected to the control circuit terminals to input a frequency reference.
Calibrates the scale of frequency meters and ammeters.
* 1. Use a ground fault interrupter with a current sensitivity of 200 mA minimum and an operating time of 0.1 s minimum to prevent operating errors. The interrupter must be suitable for high-frequency operation.
Example:NV series by Mitsubishi Electric Corporation (manufactured in or after 1988)
EG, SG series by Fuji Electric Co., Ltd. (manufactured in or after 1984)
* 2. The Finemet Zero-phase Reactor is manufactured by Hitachi Metals, Ltd.
9-
5
9
-6
Built-in
(connect to connector)
Type
The following option boards are available
Table 9.5 Option Boards
Name
Code Number
Function
Analog Reference Board
AI-14U
73600-
C001X
Enables high-precision, high-resolution setting of analog speed references.
• Input signal ranges: 0 to 10 V (20 k Ω ), 1 channel
4 to 20 mA (250 Ω ), 1 channel
• Input resolution: 14-bit (1/16384)
Speed
(Frequency)
Reference
Option
Boards
Analog Reference Board
AI-14B
Digital Reference Board
DI-08
Digital Reference Board
DI-16H2
Analog Monitor Board
AO-08
Monitoring
Option
Boards
Analog Monitor Board
AO-12
Digital Output Board
DO 08
73600-
C002X
73600-
C003X
73600-
C016X
73600-
D001X
73600-
D002X
73600-
D004X
Enables high-precision, high-resolution setting of analog speed references.
• Input signal ranges: 0 to ±10 V (20 k Ω )
4 to 20 mA (500 Ω ), 3 channels
• Input resolution: 13-bit + sign (1/8192)
Enables 8-bit digital setting of speed references.
• Input signal: 8-bit binary
2-digit BCD + sign signal + set signal
• Input voltage: +24 V (isolated)
• Input current: 8 mA
Enables 16-bit digital setting of speed references.
• Input signal: 16-bit binary
4-digit BCD + sign signal + set signal
• Input voltage: +24 V (isolated)
• Input current: 8 mA
With 16-bit/12-bit switch.
Converts analog signals to monitor the Inverter's output status
(output frequency, output current, etc.) to absolute values and outputs them.
• Output resolution: 8 bits (1/256)
• Output voltage: 0 to +10 V (not insulated)
• Output channels: 2 channels
Output analog signals to monitor the Inverter's output status
(output frequency, output current, etc.).
• Output resolution: 11 bits (1/2048) + sign
• Output voltage: -10 to +10 V (not insulated)
• Output channels: 2 channels
Outputs isolated digital signals to monitor the Inverters operating status (alarm signals, zero-speed detection, etc.)
Output form: Photocoupler output, 6 channels
(48 V, 50 mA max.)
Relay contact outputs, 2 channels
(250 VAC: 1 A max., 30VDC: 1 A max.)
2C-Relay
Output Board
DO 02C
73600-
D007X
Provides two multi-function outputs (DPDT relay contacts) in addition to those provided by the Inverter.
PG
Speed
Control
Boards
PG A2
73600-
A012X
Used for V/f with PG control. Speed feedback is performed using the PG attached to the motor to compensate for speed fluctuations caused by slipping.
• A-phase pulse (single pulse) input (voltage, complementary, open-collector input)
• Maximum input frequency: 32767 Hz
• Pulse monitor output: +12 V, 20 mA
(PG power supply output: +12 V, 200 mA max.)
Document
Number
TOE-C736-
30.13
TOE-C736-
30.14
TOE-C736-
30.15
TOE-C736-
40.7
TOE-C736-
30.21
TOE-C736-
30.22
TOE-C736-
30.24
TOE-C736-
40.8
TOE-C736-
40.1
Specifications of Options and Peripheral Devices
(concon-
Type
Built-in nect to nector)
PG
Speed
Control
Boards
Name
PG
PG
-
-
B2
D2
PG-X2
Built-in
(connected to connector)
Communications
Option
Boards
CANopen
Communications Interface Board
SI-S
CC-Link
Communications Interface Board
SI-C
L ON W ORKS
Communications Interface Board
SI-J
L ON W ORKS
Communications Interface Board
SI-W1
DeviceNet
Communications Interface Board
SI-N1
ProfiBus-DP
Communications Interface Board
SI-P1
InterBus-S
Communications Interface Board
SI-R
Table 9.5 Option Boards (Continued)
Code Number
Function
73600-
A013X
• Used for V/f control with PG and flux vector control.
• A-, B-phase input (complimentary input)
• Maximum input frequency: 32767 Hz
• Pulse monitor output: Open-collector
(PG power supply output: +12 V, 200 mA max.)
73600-
A014X
73600-
A015X
• Differential input.
• A-phase pulse (differential pulse) input, for V/f control
• Maximum input frequency: 300 kHz
• Input: Conforms to RS-422
• Pulse monitor output: RS-422
(PG power supply output: +5 or +12 V, 200 mA max.)
• A-, B-, Z-phase pulse (differential pulse) input
• Maximum input frequency: 300 kHz
• Input: Conforms to RS-422
• Pulse monitor output: RS-422
(PG power supply output: +5 or +12 V, 200 mA max.)
73600-
C021X
Used to communicate with an Inverter from a host computer using DeviceNet communications to start/stop Inverter operation, read/set parameters, and read/set monitor constants (output frequencies, output currents, etc.).
73600-
C033X
*
*
73600-
C032X
73600-
C035X
73600-
C034X
Used to communicate with an Inverter from a host computer using ProfiBus-DP communications to start/stop Inverter operation, read/set parameters, and read/set monitor constants
(output frequencies, output currents, etc.).
Used to communicate with an Inverter from a host computer using InterBus-S communications to start/stop Inverter operation, read/set parameters, and read/set monitor constants (output frequencies, output currents, etc.).
Used to communicate with an Inverter from a host computer using CANopen communications to start/stop Inverter operation, read/set parameters, and read/set monitor constants (output frequencies, output currents, etc.).
Used to communicate with an Inverter from a host computer using CC-Link communications to start/stop Inverter operation, read/set parameters, and read/set monitor constants (output frequencies, output currents, etc.).
Used to communicate with an Inverter from a host computer using L ON W ORKS communications to start/stop Inverter operation, read/set parameters, and read/set monitor constants
(output frequencies, output currents, etc.).
Used to communicate with an Inverter from a host computer using L ON W ORKS communications to start/stop Inverter operation, read/set parameters, and read/set monitor constants
(output frequencies, output currents, etc.).
With Display Data Channel (DDC) function.
Document
Number
TOE-C736-
40.2
TOE-C736-
40.3
TOE-C736-
40.4
-
-
-
-
-
-
-
9-
7
9
-8
Type Name
Built-in
(connected to connector)
Communications
Option
Boards
MECHA-
TROLINK-
Communications Interface Board
SI-T
Table 9.5 Option Boards (Continued)
Code Number
Function
73600-
C030X
Used to communicate with an Inverter from a host computer using MECHATROLINK communications to start/stop
Inverter operation, read/set parameters, and read/set monitor constants (output frequencies, output currents, etc.).
Document
Number
Appendix
This chapter provides precautions for the Inverter, motor, and peripheral devices and also provides lists of constants.
Varispeed F7 Control Methods ..................................10-2
Inverter Application Precautions ................................10-6
Motor Application Precautions ...................................10-9
Conformance to UL Standard .................................. 10-11
Conformance to CE Markings..................................10-13
Wiring Examples......................................................10-22
User Constants ........................................................10-31