Standard Wiring. YASKAWA VS mini CIMRJ7 A40P2 Series, VS MINI J7, VS mini CIMRJ7 A20P4 Series, VS mini CIMRJ7 AB0P1 Series, VS mini CIMRJ7 A20P7 Series, VS mini CIMRJ7 A20P2 Series, VS mini CIMRJ7 A21P5 Series, VS mini CIMRJ7 A42P2 Series, VS mini CIMRJ7 AB0P2 Series, VS mini CIMRJ7 AB1P5 Series
Advertisement
Advertisement
9. Specifications
Standard Wiring
U
DC Reactor
(Option)
X
Short-circuit bar
*1
MCCB
R
For single-phase, use R/L1 and S/L2.
S
T
FORWARD
RUN/STOP
REVERSE
RUN/STOP
FAULT RESET
EXTERNAL FAULT
(NO Contact)
MULTI-STEP
SPEED REF.1
S1
S2
S3
S4
S5
+2
R/L1
S/L2
T/L3
+1
−
2 k Ω
P P
Frequency Setting
Potentiometer
U/T1
V/T2
W/T3
IM
MA
MB
MC
RUNNING
Multi-function
*2 output
250 VAC 1 A or less
30 VDC 1 A or less
SC
Shielded Connection
Terminal
FS Frequency Setting Power Supply
(+12 V 20 mA)
FR
FC
Speed Frequency Reference
0 to +10 V (20 k Ω ) or
4 to 20 mA/0 to 20 mA (250 Ω )
0 V
Digital Operator
Frequency
Setting
Volume
MIN MAX
AM
AC
P FM
Analog Monitor
Output
0 to +10 VDC
(2 mA)
Output Frequency
Shielded P Shielded twisted-pair cable
: Only basic insulation (Protective class 1, overvoltage categoly II) is provided for the
control circuit terminals. Additional insulation may be necessary in the end product
to conform to CE requirements.
*1. Shorting bar must be removed when connecting DC reactor.
*2. Minimum permissible load: 5 VDC, 10 mA (as reference value)
113
114
Terminal Descriptions
Type Terminal
R/L1, S/L2,
T/L3
Name
AC power supply input
Function (Signal Level)
Use main circuit power input. (Use terminals
R/L1 and S/L2 for single-phase Inverters.
Never use terminal T/L3.)
Inverter output U/T1, V/T2,
W/T3
+2, +1
Inverter output
+1, -
DC reactor connection
DC power supply input
Grounding
When connecting optional DC reactor, remove the main circuit short-circuit bar between +2 and +1.
DC power supply input (+1: positive − : negative) *1
For grounding (according to the local grounding codes)
S1
S2
S3
Forward run input
Multi-function input selection 2
Multi-function input selection 3
Closed: FWD run, open: REV run
Factory setting closed:REV run open: FWD run
Factory setting: Fault reset
Photocoupler insulation,
24 VDC,
8 mA
S4
S5
SC
FS
Multi-function input selection 4
Multi-function input selection 5
Multi-function input selection common
Power for frequency setting
Factory setting: External fault (NO contact)
Factory setting: Multi-step speed reference 1
For control signal
+12 V (permissible current 20 mA max.)
FR
FC
MA
MB
Master speed frequency reference
Frequency reference common
NO contact output
NC contact output
0 to +10 VDC (20 k Ω ) or 4 to 20 mA (250 Ω ) or 0 to 20 mA (250 Ω ) (1/1000 resolution)
0 V
Factory setting: running Contact capacity
250 VAC 1 A or less,
30 VDC 1 A or less
MC Contact output common
AM
AC
Analog monitor output
Analog monitor common
Factory setting: Output frequency 0 to +10 VDC
0 V
0 to +10
VDC, 2 mA or less,
8-bit resolution
* 1. DC power supply input terminal is not applied to CE/UL standard.
* 2. Minimum permissible load: 5 VDC, 10 mA (as reference value)