Keyboard Modes. Psion GM3WCF2011BE, 7535 Hand-Held Computer
விளம்பரம்
விளம்பரம்
Chapter 5: Configuration
Power Management Properties
5.3.3 Power Management Properties
This menu item displays a Power Properties dialogue box that indicates the unit’s battery capacity and allows you to manage battery use.
• In the
Control Panel
, choose the
Power
icon.
Figure 5.10 Choosing The Power Icon
5.3.3.1
Battery Capacity
• In the Power Properties dialogue box, open the Battery tab.
Figure 5.11 Power Battery Properties
The
Battery
tab details information about the battery installed in your 7535.
Teklogix 7535 Hand-Held Computer User Manual 83
Chapter 5: Configuration
Power Saving Schemes
5.3.3.2
Power Saving Schemes
• In the Power Properties dialogue box, open the Schemes tab.
Figure 5.12 Power Scheme Properties
Note: The Power Properties
Scheme
settings are cumulative – that is, to determine when the 7535 enters ‘Suspend’ state, the unit waits for the ‘User Idle’ state to elapse, followed by the ‘System Idle’ state and then, once the
‘Suspend’ state time has elapsed, ‘Suspend’ state is activated.
When setting the
User Idle State
,
System Idle State
and
Suspend State
, keep the following in mind. Because the 7535 ‘wakes up’ from the
User Idle
and
System Idle
states almost instantaneously following any user input (keypress, trigger press, screen tap), the timeouts you set will not slow user activity. The sum of the
User Idle
,
System Idle
and
Suspend
timeouts should be selected carefully since the 7535 will go to sleep (appear off) when this time has elapsed, saving battery power. Psion Teklogix recommends starting with a total of 10 minutes for this timeout. Setting any of these timeouts to
‘Never’ will adversely affect the battery run time.
To further reduce power consumption, carefully consider the duration of time that the display backlight is ‘on’ (see “Display Backlight” on page 77).
Power Scheme
This dropdown menu allows you to identify whether the unit is using
AC Power
or
Battery Power
.
User Idle State
User Idle
means that the 7535 is not receiving any user input including activities like a key touch, a scan, and so on – any user initiated activity. When the time selected in the ‘
Switch state to User Idle
’ menu elapses, the hand-held enters a
User Idle
state and begins to monitor the time specified in the
System Idle
state menu.
84 Teklogix 7535 Hand-Held Computer User Manual
Chapter 5: Configuration
Calibrating The Touchscreen
System Idle State
System activity includes computer activity such as serial data, an activity initiated by an application, and so on – any activity not executed by the user.
System Idle
is activated when the time specified in the ‘
Switch state to User Idle
’ and the ‘
Switch state to
System Idle
’ menu have elapsed without any activity. The 7535 begins to monitor the
Suspend
field.
Suspend State
Once the time specified in the
User Idle
and the
System Idle
fields have elapsed, the 7535 begins to count down the time specified in the ‘
Switch state to Suspend
’. When the time in the
Suspend
field elapses, the unit enters
Suspend
state.
In
Suspend
state, the 7535 CPU enters a sleep state and all peripherals are powered down to minimize power consumption. The state of the device (RAM contents) is preserved. Pressing <ENTER> or the <SCAN> button wakes the system from suspend state. When the 7535 is in suspend state, the network connection is broken.
To resume, you must re-establish the network connection.
5.3.4 Calibrating The Touchscreen
Note: Touchscreen calibration may not be enabled on your unit. If your screen appears to require recalibration, contact your supervisor.
Touchscreens rarely require recalibration. However, if your touchscreen has never been calibrated or if you find that the stylus pointer is not accurate when you tap on an item, follow the directions below.
• In the Control Panel , select the Stylus icon to display the Stylus Properties window.
Figure 5.13 Stylus Icon
Teklogix 7535 Hand-Held Computer User Manual 85
Chapter 5: Configuration
Advanced Configuration
• Choose the Calibration tab and then the Recalibrate button.
Figure 5.14 Calibration Screen
• Follow the directions on the calibration screen to recalibrate the screen.
5.4 Advanced Configuration
5.5 Scanner Properties
The
Scanner Properties
icon in the
Control Panel
provides dialogue boxes in which you can tailor bar code options and choose the bar codes your scanner will recognize.
Figure 5.15 Bar Code Options
86 Teklogix 7535 Hand-Held Computer User Manual
Chapter 5: Configuration
Scanner Options
5.5.1 Scanner Options
Verify
The value entered for this parameter determines the number of correct additional decodes required after the initial decode before a bar code is accepted. Higher values significantly increase the time it takes to decode a bar code but also improve the reliability of the decoded bar code.
Security
This parameter controls the tolerance for decoding edge-to-edge bar codes
(Code 93, Code 128, UPC/EAN). Lower values have a lower tolerance for misreads, but they also increase the time it takes to decode the bar code. The default value of
30 is generally a good compromise setting.
Short Code
When enabled (
√
), this parameter allows scanning of short I 2 of 5 bar codes (2 characters). When disabled, these short bar codes are rejected.
Enabling “Short Code” may reduce the robustness of the decoding since the
7535 must decode more potential bar codes; it is therefore not recommended for general-purpose bar codes with 4 or more characters.
Double Click Options
Click Time
Note: This parameter only affects 7535s using scanners with aiming dot capability.
This parameter controls the maximum gap time (in milliseconds) for a double-click.
If the time between the first and second clicks of the scanner trigger is within this time, it is considered a double-click. The allowable range is 0 to 1000 . A value of zero disables this feature.
A double-click produces different results depending on whether or not a value is assigned in the “Click Data” parameter. When a value is not assigned for the “Click
Data”, double-clicking the scanner trigger overrides the target dot delay set in the
“Dot Time” parameter and initiates a normal scan sweep. If a value is assigned for the “Click Data” parameter, double-clicking the scanner trigger inserts the “Click
Data” value rather than initiating a scan.
Teklogix 7535 Hand-Held Computer User Manual 87
Chapter 5: Configuration
Scanner Options
Click Data
For both integrated and external scanners, this parameter determines which character is sent to the application installed in your 7535 following a double-click.
Enter the ASCII value of the character desired from 0 to 255 . You can also press the
<LEFT> or <RIGHT> arrow keys to scroll through a set of ASCII characters not available from the keyboard.
Display Options
Indicator
When this parameter is enabled (
√
), the laser warning logo appears on the display whenever the scanner is activated.
Result
When this parameter is enabled (
√
), the type of bar code and the result of the scan appear on the screen. Note that this information is only displayed after a successful decode and is visible only while the scanner trigger is pressed. When the trigger is released, this information is cleared from the screen.
Dot Time
The value selected for “Dot Time” determines how long the targeting dot remains on before the scanner switches to a normal scan sweep. The allowable values are:
0, 0.1, 0.5, 1.0, 1.5, 2.0, 2.5 and 3.0 seconds. A value of 0 (zero) disables the target dot.
Result Time
The value assigned to the “Result Time” parameter determines how long the scan results of a successful scan are displayed on the screen. Time is measured in seconds, and a value of “0” (zero) disables the parameter.
Note: To remove the scan result from the screen before the “Result Time” has expired, perform an unsuccessful scan.
88 Teklogix 7535 Hand-Held Computer User Manual
Chapter 5: Configuration
Bar Codes
5.5.2 Bar Codes
Figure 5.16 Bar Code Selection
All the available bar code symbologies can be selected from this menu. For each symbology, there are options in a ‘Settings’ and a ‘Size/Char’ sub-menu. The unit automatically discriminates between the selected codes. Some restrictions may apply.
Important: To improve the decode speed and performance, enable (
√
) only those codes that are required by the application.
Teklogix 7535 Hand-Held Computer User Manual 89
Chapter 5: Configuration
Bar Code Settings
5.5.3 Bar Code Settings
Figure 5.17 Code 39 Bar Code Settings
Note: Options that are not available with a particular bar code are displayed in grey characters like the ‘Addendum’ option in the sample screen above and are not accessible in the dialogue box.
5.5.3.1
Code 39 Settings
Full Ascii
If this parameter is enabled (
√
), the characters +, %, and / are used as escape characters. The combination of an escape character and the next character is converted to an equivalent ASCII character.
Include Chk
If this parameter is enabled (
√
), the check digit is included with the decoded bar code data.
AIAG Strip
If this parameter is enabled (
√
), the AIAG data identifier is removed from each decoded Code 39 label. The data identifier occurs in the first position next to the
Code 39 start character. It can be a single alphabetic character or a series of numeric digits followed by an alphabetic character. This identifier defines the general category or specific use of the data contained in the rest of the bar code.
90 Teklogix 7535 Hand-Held Computer User Manual
Chapter 5: Configuration
Code 39 Settings
Note: If your unit is operating with the Psion Teklogix TESS application, this parameter should not be used in conjunction with the TESS AIAG feature.
This is because the 7535 hand-held performs the strip function before it processes the data through the AIAG feature; if the prefix is stripped, the data is not identified as AIAG.
Err Accept
If the “Err Accept” and “AIAG Strip” parameters are enabled (
√
), all label data without an AIAG identifier character is accepted. If the “Err Accept” parameter is disabled and the “AIAG Strip” parameter is enabled (
√
), the label data is not accepted.
Mod Chks
Mod 43 Chk
If this parameter is enabled (
√
), the Mod 43 check digit is calculated.
Mod 10 Chk
If this parameter is enabled (
√
), the Mod 10 check digit is calculated.
None
If you choose ‘None’, a check is not executed.
Size/Chars
Figure 5.18 Size And Character Settings
Teklogix 7535 Hand-Held Computer User Manual 91
Chapter 5: Configuration
Code 39 Settings
Field Size
The field size is the length of the field after the first character is stripped and the prefix and suffix characters are added. If the field size is non-zero, only bar codes of that length are passed through.
Prefix Char
This character, if non-zero, is added before a successfully decoded bar code.
Enter the ASCII decimal equivalent of this character. Enter a value of 0 (zero) if no prefix is to be added.
Suffix Char
This character, if non-zero, is added after a successfully decoded bar code.
Enter the ASCII decimal equivalent of this character. Enter a value of 0 (zero) if no suffix is to be added.
Strip Leading
This parameter determines the number of characters that will be removed from the beginning of the bar code before the prefix character is added.
Notes: 1.
The appended character is treated as any other keyboard character.
For example, if <BKSP> is pressed, the usual action for that key is performed. If your unit is operating with the Psion Teklogix ANSI emulation application, the 7535 transmits the escape sequence associated with the function immediately after the bar code data.
2. For Code 39 bar codes, the “AIAG Strip” is performed before the
“Strip Leading”.
Strip Trailing
The value entered in this parameter determines the number of characters that will be removed from the end of the bar code before the suffix character is added.
92 Teklogix 7535 Hand-Held Computer User Manual
5.5.3.2
Code 128 Settings
Chapter 5: Configuration
Code 128 Settings
Figure 5.19 Code 128 Bar Code Options
Include Sym
Enabling (
√
) “Include Sym” causes the group separator(s) and start code contained in this type of bar code to be displayed on the screen.
Note: This option is available only when ‘EAN/UCC 128’ is selected.
Variations
When using Code 128, you can choose the variation or type of bar code variation the scanner will recognize. The options available are Standard , UCC and EAN/UCC .
These options are described below.
Standard
Enable (
√
) “Standard” if Code 128 is desired.
UCC 128
“UCC” is a variation of Code 128.
EAN/UCC 128
To successfully scan this type of bar code, “EAN/UCC” must be enabled (
√
).
“EAN/UCC” bar codes include group separators and start codes.
Size/Chars
Refer to the description beginning on page 91 for details.
Teklogix 7535 Hand-Held Computer User Manual 93
Chapter 5: Configuration
EAN 13 Settings
5.5.3.3
EAN 13 Settings
Figure 5.20 Ean 13 Settings
Inc Country
If this parameter is enabled (
√
), the country code is included with the decoded bar code data.
Include Chk
If this parameter is enabled (
√
), the check digit is included with the decoded bar code data.
Addendum
Important: Before “Addendum” can take effect, the “Short Code” parameter in the Options menu (see page 87) must be enabled (
√
).
An addendum is a separate bar code, supplementary to the main bar code.
This parameter provides three options: Disabled, Optional and Required .
Depending on the value chosen for this parameter, an addendum is recognized or ignored.
When “Addendum” is set to Disabled, the scanner does not recognize an addendum. If this parameter is set to Optional, the scanner searches for an addendum and if one exists, appends it to the main bar code. When the parameter is set to Required, the scanner does not accept the main bar code without an addendum.
94 Teklogix 7535 Hand-Held Computer User Manual
Chapter 5: Configuration
EAN 13 Settings
Size/Chars
Figure 5.21 Size/Char Dialogue Box
Prefix Char
This character, if non-zero, is added before a successfully decoded bar code.
Enter the ASCII decimal equivalent of this character. Enter a value of 0 (zero) if no prefix is to be added.
Suffix Char
This character, if non-zero, is added after a successfully decoded bar code.
Enter the ASCII decimal equivalent of this character. Enter a value of 0 (zero) if no suffix is to be added.
Strip Leading
This parameter determines the number of characters that will be removed from the beginning of the bar code before the prefix character is added.
Note: 1.The appended character is treated as any other keyboard character. For example, if <BKSP> is pressed, the usual action for that key is performed. If your 7535 is operating with the Psion Teklogix ANSI emulation application, the hand-held transmits the escape sequence associated with the function immediately after the bar code data.
Strip Trailing
The value entered in this parameter determines the number of characters that will be removed from the end of the bar code before the suffix character is added.
Teklogix 7535 Hand-Held Computer User Manual 95
Chapter 5: Configuration
EAN 8
5.5.3.4
EAN 8
Figure 5.22 EAN 8 Settings
Include Chk
If this parameter is enabled (set to “Y”), the check digit is included with the decoded bar code data.
Addendum
Important: Before “Addendum” can take effect, the “Short Code” parameter in the Options menu (see page 87) must be enabled (
√
).
Refer to “Addendum” on page 94.
Size/Chars
See “Size/Chars” beginning on page 95.
96 Teklogix 7535 Hand-Held Computer User Manual
5.5.3.5
UPC And EAN Settings
Chapter 5: Configuration
UPC And EAN Settings
Figure 5.23 UPC And EAN Settings
Supplementals
Enabling (
√
) this parameter allows supplementary data to be decoded.
Size/Char
Refer to page 91 for details.
5.5.3.6
UPC A Settings
Figure 5.24 UPC A Settings
Teklogix 7535 Hand-Held Computer User Manual 97
Chapter 5: Configuration
UPC E Settings
Inc Num Sys
If this parameter is enabled (
√
), the number system digit is included with the decoded bar code data.
Include Chk
If this parameter is enabled (
√
), the check digit will be included with the decoded bar code data.
Addendum
Important: Before “Addendum” can take effect, the “Short Code” parameter in the Options menu (see page 87) must be enabled (
√
).
Refer to “Addendum” on page 94.
Size/Chars
Refer to page 95 for details.
5.5.3.7
UPC E Settings
Figure 5.25 UPC E Settings
Exp to UPC A
Enabling (
√
) this parameter results in a non-standard decoding that returns 12 digits from the 6 digit UPC E bar code.
98 Teklogix 7535 Hand-Held Computer User Manual
Chapter 5: Configuration
Codabar Size And Characters
Inc Num Sys
If this parameter is enabled (
√
), the number system digit is included with the decoded bar code data.
Include Chk
When enabled (
√
), the check digit is included with the decoded bar code data.
Addendum
Important: Before “Addendum” can take effect, the “Short Code” parameter in the Options menu (see page 87) must be enabled (
√
).
Refer to “Addendum” on page 94.
Size/Chars
Refer to page 95 for details.
5.5.3.8
Codabar Size And Characters
Size/Char
Refer to page 91 for details.
5.5.3.9
Code 93 Size And Characters
Size/Char
Refer to page 91 for details.
Teklogix 7535 Hand-Held Computer User Manual 99
Chapter 5: Configuration
Code 11
5.5.3.10
Code 11
Figure 5.26 Code 11 Settings
Include Chk
If “Include Chk” is enabled (
√
), the check digit is included with the decoded bar code data.
1 Chk Digit
If this parameter is enabled (
√
), it is assumed that the last digit is a check digit.
2 Chk Digits
If this parameter is enabled (
√
), it is assumed that the last two digits are check digits.
Size/Chars
Refer to page 91 for details.
100 Teklogix 7535 Hand-Held Computer User Manual
5.5.3.11
I 2 of 5 Settings
Chapter 5: Configuration
I 2 of 5 Settings
Figure 5.27 I 2 of 5 Settings
Mod 10 Chk
If this parameter is enabled (
√
), the Mod 10 check digit is calculated. This calculation is the same as the Code 39 Mod 10 check digit.
ITF Chk
If this parameter is enabled (
√
), the ITF-14/16 Mod10 check digit is calculated.
Include Chk
If this parameter is enabled (
√
), the check digit is included with the decoded bar code data.
Size/Chars
Refer to page 91 for details.
Teklogix 7535 Hand-Held Computer User Manual 101
Chapter 5: Configuration
MSI/PLESSY Settings
5.5.3.12
MSI/PLESSY Settings
Figure 5.28 MSI/PLESSY Settings
1 Chk Digit
If this parameter is enabled (
√
), it is assumed that the last digit is a check digit.
Include Chk
If this parameter is enabled (
√
), the check digit is included with the decoded bar code data.
Size/Chars
Refer to page 91 for details.
102 Teklogix 7535 Hand-Held Computer User Manual
5.5.3.13
D 2 of 5 Settings
Chapter 5: Configuration
D 2 of 5 Settings
Figure 5.29 D 2 of 5 Settings
Mod 10 Chk
If this parameter is enabled (
√
), the Mod 10 check digit is calculated. This calculation is the same as the Code 39 Mod 10 check digit.
ITF Chk
If this parameter is enabled (
√
), the ITF-14/16 Mod10 check digit is calculated.
Include Chk
If this parameter is enabled (set to “Y”), the check digit is included with the decoded bar code data.
Size/Chars
Refer to page 91 for details.
Teklogix 7535 Hand-Held Computer User Manual 103
Chapter 5: Configuration
IATA 2 of 5 Settings
5.5.3.14
IATA 2 of 5 Settings
Figure 5.30 IATA 2 of 5 Settings
Mod 10 Chk
If this parameter is enabled (
√
), the Mod 10 check digit is calculated.
ITF Chk
If this parameter is enabled (
√
), the ITF-14/16 Mod10 check digit is calculated.
Include Chk
If this parameter is enabled (
√
), the check digit is included with the decoded bar code data.
Size/Chars
Refer to page 91 for details.
5.5.3.15
Postal: Australian
Size/Chars
Refer to page 91 for details.
104 Teklogix 7535 Hand-Held Computer User Manual
பதிவிறக்கு
விளம்பரம்