6.17.2.3 Characters. Psion GM3WCF2011BE, 7535 Hand-Held Computer
જાહેરાત
જાહેરાત
Chapter 6: Tekterm Application
Screen
6.17.2.2 Screen
05 Screen
# of Cols
# of Rows
Origin Scroll
Field Scroll
80
Pages Saved
Fields/Page
App. Parameter 0
Label F1-6 »
Colour Override N»
24
N
N
16
80
Range
20..132
4..100
Y/N
Y/N
1..16
20..80
-1..79
see text see text
# of Cols
This parameter defines the logical page width (in characters) used by the host computer application. Emulator systems trim the host application screens to this width. This page width cannot be smaller than the width of the 7535 display.
Display panning is used if the page is wider than the display.
Note: The value in this parameter must be an even number.
# of Rows
This parameter defines the logical page length (in lines) used by the host computer application. Emulator systems trim the host application screens to this length. This page length cannot be smaller than the length of the hand-held computer’s display.
Display panning is used if the page is longer than the display.
Note: The value in this parameter must be an even number.
Origin Scroll
When enabled (set to “Y”), the display window moves to the origin (upper-left corner) after “LOCK-H” or “LOCK-B” messages.
Field Scroll
When enabled (set to “Y”), the display window moves to the left after entering a new entry field.
178 Teklogix 7535 Hand-Held Computer User Manual
Chapter 6: Tekterm Application
Screen
Pages Saved
This parameter determines the number of pages that can be stored and recalled at the 7535. Storing frequently used page data at the 7535 reduces the need for the host to retransmit complete page data over the radio link. Retransmitting data can reduce the system response time. Increasing the number of saved pages decreases the available memory for other functions.
App. Parameter
The “Application” parameter is sent to the host system as part of the response to the TESS query command. Enter zero to disable this parameter.
Label F1-F6
Note: This menu uses string entry fields. For detailed information about completing this type of field, refer to “String Entry Parameters” on page 135.
Label F1-6 06
F1
•
•
•
F6
Softkeys are function keys that have been programmed to perform specific actions in your application. These keys are identified through softkey labels – reverse video labels that are displayed at the bottom of the screen. These softkey labels can be reconfigured using the menu attached to the “Label F1-F6” parameter.
To edit a label:
• Position the cursor in the appropriate function key field within the
Label menu, and type a new name – preferably one that describes the corresponding key’s function.
Note: Although you can enter up to 8 characters for each softkey label, the text will be shortened to better fit in the available space on your display.
Teklogix 7535 Hand-Held Computer User Manual 179