6.17.2.7 Fields. Psion GM3WCF2011BE, 7535 Hand-Held Computer
Реклама
Реклама
Chapter 6: Tekterm Application
Scanner
SI Fkey
This parameter allows you to choose the function key you want appended to the serial input. For example, entering a value of “1” appends <F1> to serial input. A value of “0” (zero) disables this parameter; a suffix is not added.
Note: Data is transmitted as soon as the function key has been appended.
SO prefix
This parameter determines the start-of-message character on serial output. Enter an
ASCII numeric equivalent from 0 to 255 to represent the start character. A value of
“0” (zero) indicates no prefix.
SO suffix
This parameter determines the end-of-message character on serial output. Enter an
ASCII numeric equivalent from 0 to 255 to represent the end character. A value of
“0” (zero) indicates no suffix.
SO CRC
When this parameter is enabled (set to “Y”), a CRC16 value is appended to the serial output message.
Also, when this parameter is enabled (set to “Y”), for each control character in the serial output stream, a DLE is inserted to precede that character. The control character is replaced with its 1’s complement.
6.17.2.6 Scanner
05 Scanner
Cont Nxt Fld
Append Enter
Append F0
Mixed AIAG
Rjct if Alpha
Beam Lockout
Y
Y
Y
N
N
N
Range
Y/N
Y/N
Y/N
Y/N
Y/N
Y/N
186 Teklogix 7535 Hand-Held Computer User Manual
Chapter 6: Tekterm Application
Scanner
Cont Nxt Fld
This parameter only applies to string entry data. When enabled (set to “Y”), this parameter allows bar codes that are longer than the field length to continue in the next field.
If “ContNxtField” is disabled (set to “N”), OFF data will flow into the next field.
Append Enter
When enabled (set to “Y”), “Append Enter” causes an <ENTER> code to be appended to the bar code. The <ENTER> code completes the entry of the bar code and moves the cursor to the next field.
Append F0
When enabled (set to “Y”), this parameter causes an <F0> code to be appended to the bar code. The <F0> code completes the entry of the bar code data in the field.
Mixed AIAG
When this parameter is enabled (set to “Y”), AIAG labels are always accepted and processed – even if mixed with keyboard input. The AIAG label can replace the partially entered keyboard data. If this parameter is disabled, AIAG labels are rejected if field entry is in progress.
Rjct if Alpha
When the cursor is in a numeric field and “Rjct if Alpha” is enabled (set to “Y”), bar codes containing alphabetic characters are rejected.
Beam Lockout
When enabled (set to “Y”), this parameter disallows scanner use when the current session is in “LOCK-H” mode.
Teklogix 7535 Hand-Held Computer User Manual 187
Изтегляне