7.10 Bluetooth Peripherals. Psion GM3WCF2011BE, 7535 Hand-Held Computer
Реклама
Реклама
Chapter 7: Peripheral Devices & Accessories
Operator Controls
The charger can consume up to 2A @ 120VAC or 1A @ 240VAC. Check to ensure the mains circuit supplying the charger is adequate for this loading (especially if several chargers are being powered from the same circuit).
After unpacking the unit:
• Visually check the charger for damage.
• Install the IEC power cord and apply power.
A green indicator in the lower-right lights to indicate power is present. All charge indicators flash momentarily at powerup to indicate that the charger is ready for operation.
If you choose to wall mount the charger, follow the instructions packaged with the mounting bracket kit. Be sure to locate the charger in a area where there is no risk of injury to persons walking in the vicinity.
7.5.2 Operator Controls
The gang charger does not have operator controls or a power switch.
7.5.3 Charge Indicators
Each battery charge slot is equipped with a tri-coloured LED to indicate the charge status of the battery. When 7535 batteries are inserted in the charger, the colour and behaviour of the LEDs associated with the charge wells in use indicate the status of the charge.
LED Behaviour
Off
Solid green
Flashing green
Solid yellow
Flashing yellow
Solid red
Flashing red
Charge Status
No battery detected in the slot.
Battery is fully charged.
Battery is charged to 75% capacity.
Charge in progress.
Battery temperature out of charge range between 0˚ C to 39˚ C (32˚ F to 102˚ F).
Charging is attempted every five minutes until the battery is within the appropriate temperature range.
Battery rejected (at insertion) or unable to complete charge on battery
Charging circuit problem. Refer to
“Troubleshooting” on page 212.
Table 7.1 Gang Charger Indicators
Teklogix 7535 Hand-Held Computer User Manual 211
Chapter 7: Peripheral Devices & Accessories
Charging Batteries
7.5.4 Charging Batteries
• Install the battery with the battery contacts facing the charger. Slide the battery between the guide rails until it lightly latches in place.
The LED directly below the slot in which a battery is inserted lights up immediately.
A solid yellow LED indicates that the battery is being charged. If the battery temperature is outside 0˚ C to 39˚ C (32˚ F to 102˚ F), the LED flashes yellow until the temperature is acceptable. A fully discharged battery will normally take between 1.5 and 4 hours to charge. When the battery charge reaches 75%, the indicator flashes green. At full capacity, it turns solid green.
When the battery is fully charged, the charger stops applying power; the battery cannot be overcharged if left in the charger slot. The 75% charge indicator is handy if you need a quick recharge – it often occurs after less than an hour.
7.5.5 Troubleshooting
7.5.5.1
Excessive Charge Duration
The charger is equipped with a recalibration function – a function that fully discharges and then fully recharges the battery. This process is necessary to recalibrate the battery capacity gauge internal to the battery. The charger attempts recalibration when:
• the battery capacity is at less than 30%, and
• the battery has undergone more than 40 partial charge cycles since the last full discharge.
A complete battery discharge takes between 1.5 and 4 hours to complete. When in discharge mode, the LED indicator flashes yellow. The recalibration function extends the charge time by up to 2 hours.
7.5.5.2
Indicator Flashing Red
If the indicator flashes red:
• Remove all batteries and disconnect the mains power cable.
• Wait at least 20 seconds, and then plug the cable in again.
If any of the charge slot LEDs continue to flash red, the charger is defective and requires service. If all indicators are flashing red, there is a power supply problem and the charger requires service.
212 Teklogix 7535 Hand-Held Computer User Manual
Chapter 7: Peripheral Devices & Accessories
Power LED Does Not Light Up
7.5.5.3
Power LED Does Not Light Up
• Remove all batteries, and unplug the charger.
• Connect another device to the mains outlet to ensure there is power.
• Remove the IEC mains power cable from the charger, and check it for damage.
• Reconnect the mains cable in the charger and mains outlet.
If the power LED still does not light up:
• Unplug the mains cable, and check the fuse at the rear of the charger.
If the fuse appears to be intact, the charger requires service.
7.5.5.4
Indicator Does Not Light When Battery Installed
• Remove the battery, and clean the contacts on the battery and the charge slot.
• Reinstall the battery, and check that it is fully seated in the slot.
• Inspect the charge slot contacts for damage (are they bent, flattened, twisted or broken).
• Try inserting a battery that you know to be working in the charger slot.
• Reconnect the mains power cable, and check that the slot indicator flashes at powerup.
7.6 Combo Charger
The 7535 combo charger is a desktop charger designed to charge the 7535 internal battery along with a spare battery pack. The combo charger provides sufficient power to operate and fast charge the 7535 internal battery, while recharging the spare battery pack.
7.6.1 Installation
Keep the combo charger away from excessive dirt, dust and contaminants. The combo charger will not charge batteries outside an ambient temperature range of
0˚ C to 39˚ C (32˚ F to 102˚ F). It is recommended that this charger be operated at room temperature – between 18˚ C and 25˚ C (64˚ F to 77˚ F) for maximum performance.
Teklogix 7535 Hand-Held Computer User Manual 213
Chapter 7: Peripheral Devices & Accessories
Operator Controls
After unpacking the unit:
• Visually inspect the charger for possible damage.
• Install the IEC power cord and apply power.
A green LED in the lower-right corner of the front panel lights to indicate that power is present. The charge LED flashes momentarily at powerup. The charger is now ready for operation.
7.6.2 Operator Controls
The combo charger has no operator controls or power switch.
7.6.3 Using the Combo Charger With The 7535
• Gently slide the 7535 into the cradle portion of the combo charger until lightly latched. An icon is displayed indicating that the 7535 is properly installed in the combo charger – .
The battery charge LED on the 7535 lights up indicating that the unit has external power and battery charging may begin. It is safe to leave the 7535 in the combo charger cradle while it is not in use – the battery will not be overcharged.
7.6.4 7.2.4 Charging The Spare Battery
• Install the battery with the latch facing towards the rear of the charger – slide it between the guide rails until it lightly latches in place.
The LED for the slot lights up immediately. A solid yellow LED indicates the battery is being charged. A flashing yellow LED indicates that the battery temperature is outside the acceptable charge range – between 0˚ C and 39˚ C
(32˚ F to 102˚ F).
A fully discharged battery normally takes between 1.5 and 4 hours to charge. When the battery capacity reaches 75%, the LED flashes green. When the battery is at full capacity, the indicator turns solid green.
The combo charger stops applying power to the battery when it is fully charged – there is no risk of overcharge if the battery remains in the charge slot. The 75% charge indicator is handy if you need a quick recharge – a quick charge often takes less than one hour.
214 Teklogix 7535 Hand-Held Computer User Manual
Chapter 7: Peripheral Devices & Accessories
Charge Indicators
7.6.5 Charge Indicators
The spare battery charge slot has an associated tri-colour LED indicator on the lower-right area of the front panel.
LED Behaviour
Off
Solid green
Flashing green
Solid yellow
Flashing yellow
Solid red
Flashing red
Charge Status
No battery detected in the slot.
Battery is fully charged.
Battery is charged to 75% capacity.
Charge in progress.
Battery temperature outside the charge range of between
0˚ C to 39˚ C (32˚ F to 102˚ F). Charging is attempted every five minutes until the battery is within the appropriate temperature range.
Battery rejected (at insertion) or unable to complete charge on battery.
Charging circuit problem. Refer to “Troubleshooting” on page 212 for details.
Table 7.2 Combo Charger Indicators
The combo charger supplies DC power to enable the 7535 internal fast charger.
Charge status is displayed on the 7535 charge LED – the lower-right LED. Refer to
“Charge LEDs” on page 46 for details.
Normally, it takes 1.5 and 4 hours to fully charge the 7535 internal battery.
Note: Battery charging continues whether the 7535 is switched on or off.
7.6.6 Troubleshooting
The gang charger troubleshooting section also applies to the combo charger. Refer to “Troubleshooting” on page 212, for helpful tips.
Teklogix 7535 Hand-Held Computer User Manual 215
Chapter 7: Peripheral Devices & Accessories
Combo Dock
7.7 Combo Dock
The combo dock is identical to the combo charger with one exception – the combo dock is equipped with a 10/100 BaseT Ethernet interface. The charging information in “Combo Charger” beginning on page 213 also applies to the combo dock.
7.7.1 Installation
Refer to the “Installation” guidelines for the combo charger beginning on page 213.
• Attach a CAT5 RJ45 network patch cable (shipped with the combo dock) between your network and the RJ45 jack on the rear of the dock.
A green LED is illuminated next to the RJ45 connector when a valid network link is established.
A user application needs to be loaded onto each 7535 that utilizes the combo dock for communication. With the network connected and this application loaded, the combo dock is ready for use.
7.7.2 Using The Combo Dock
• Gently slide the 7535 into the cradle portion of the combo dock until lightly latched. The 7535 detects combo dock and displays the appropriate icon – .
The battery charge LED (lower-right LED) on the 7535 lights up to show it has external power and may start charging the battery.
Interaction with the 7535 while in the combo dock is a function of the user application software used to communicate with the host network.
7.7.3 Network Access
The combo dock includes a dedicated USB to Ethernet converter. This USB converter appears as a USB slave to the 7535 USB host controller. The 7535 automatically detects insertion into a combo dock and loads the appropriate drivers to communicate with the USB/Ethernet converter.
See “Network Addressing” on page 218 for details about network addressing issues with the combo dock.
216 Teklogix 7535 Hand-Held Computer User Manual
Chapter 7: Peripheral Devices & Accessories
Troubleshooting
7.7.4 Troubleshooting
Troubleshooting issues for the combo dock are identical to those of the quad dock.
Refer to “Troubleshooting” on page 219 for helpful tips.
7.8 Quad Dock
The Quad Dock permits each of four docked 7535 hand-helds to communicate with a 10/100 BaseT Ethernet network at greater than 2Mbps. It also provides sufficient power to operate and fast charge the batteries the 7535s.
7.8.1 Installation
The quad dock should be located away from excessive dirt, dust and contaminants.
The ambient temperature must fall between 0˚ C to 39 ˚C (32˚ F to 102˚ F). The
7535 internal charger will not charge batteries outside of this temperature range. For maximum performance, it is recommended that the quad dock be operated at room temperature – from 18˚ C to 25˚ C (64˚ F to 77˚ F).
The quad dock can consume up to 3A @ 120VAC or 1.5A @ 240VAC. Ensure that the mains circuit supplying the unit is adequate, especially if several docks are being powered from the same circuit.
After unpacking the unit:
• Visually inspect the unit for any damage.
• Install the IEC power cord and apply power.
A green indicator in the lower-right corner of the front panel lights up to indicate that power is present.
• Attach a CAT5 RJ45 network patch cable (supplied) between your network and the RJ45 jack on the rear of the dock.
A green LED is illuminated next to the RJ45 connector when a valid network link is established.
A user application must be loaded onto each 7535 that utilizes the quad dock for communication. When the network is connected and this application is loaded, the quad dock is ready for use.
Teklogix 7535 Hand-Held Computer User Manual 217
Chapter 7: Peripheral Devices & Accessories
Indicators And Controls
7.8.2 Indicators And Controls
The quad dock has no user controls. It is equipped with a power indicator LED and
RJ45 link and traffic indicator LEDs. When a valid network link is established, a green LED is illuminated next to the RJ45 connector.
7.8.3 Using The Quad Dock
• Gently slide the 7535 into the cradle portion of the quad dock until lightly latched.
The 7535 detects that it is in a quad dock and displays the appropriate icon in the taskbar – . The battery charge LED on the 7535 lights up to show it has external power and may start charging the battery.
Interaction with the 7535 while in the quad dock is a function of the user application software used to communicate with the host network.
7.8.4 Network Access
The quad dock includes a four port 10/100 Ethernet hub. Each of the four downstream ports are connected to dedicated USB-to-Ethernet converters. These
USB converters appear as USB slaves to the 7535 USB host controller. The 7535 automatically detects insertion into a quad dock and loads the appropriate drivers to communicate with the USB/Ethernet converters.
7.8.4.1
Network Addressing
Although the USB converters have fixed Ethernet MAC addresses, there is generally no correlation between these addresses and a specific 7535 hand-held. The host application uses a standard TCP/IP protocol to name, locate and communicate with a 7535 on the network.
If a link is established between a 7535 and a host, the application on the host and on the 7535 must have a recovery mechanism in the event that the 7535 is removed from the dock and the link is interrupted.
218 Teklogix 7535 Hand-Held Computer User Manual
Скачать
Реклама