2. DATA EXTRACTION FROM FIXED DRU. Furuno VR-7000

Add to My manuals
28 Pages

advertisement

2. DATA EXTRACTION FROM FIXED DRU. Furuno VR-7000 | Manualzz

2.

DATA EXTRACTION FROM FIXED

DRU

2.1

No Damage to the DCU or Cables

1. Make the connections shown below.

Remote alarm panel (RAP)

DCU

J309 (RAP) port:

Connect the remote alarm panel (RAP).

J311 (DRU POWER) port:

Connect the power cable of the fixed DRU.

TTYCSLA-4 cable

Fixed DRU

PC

Power cable

LAN cable:

Disconnect the LAN cable from the J25 port, then connect it to the LAN port on the PC.

2. Wait until the alert 412176 “FixedDRU is stopped from recovering“ appears on the remote alarm panel. This takes approx. 10 minutes.

3. Activate the Live Player V5 on the PC to extract the data.

For how to extract the data, see chapter 5. After extracting the data, reconnect the cables.

2.2

Damage to the DCU

When the DCU is damaged, or you remove the fixed DRU to extract the data on shore, prepare the external power supply (24 VDC) for the fixed DRU.

1. Make the connections shown below.

External power supply

Fixed DRU

24 VDC

PC

Power cable

LAN cable

7

2. DATA EXTRACTION FROM FIXED DRU

The signals of the terminal board in the fixed DRU are shown below.

SOCKET 1 SOCKET 5

㪈 㪉 㪊 㪋 㪌

㪍 㪎 㪏 㪐 㪈㪇

SOCKET 6 SOCKET 10

Terminal board in the fixed DRU (front view)

Socket number

1

2

3

4

5

6

7

8

9

10

Signal

24 V

24 V

0 V

0 V

N/C

TD_P

TD_N

RD_P

RD_N

N/C

Cable

Power cable

No connection

Power cable

No connection

No connection

LAN cable

No connection

2. Start the Live Player V5 on the PC to extract the data.

For how to extract the data, see chapter 5. After extracting the data, reconnect the cables.

2.3

How to Remove the Fixed DRU

When the fixed DRU is not damaged, remove the fixed DRU for data extraction as follows:

Note: In an emergency situation, priority must be given to evacuation of personnel. Remove the fixed DRU only when there is enough time to do so.

1. Turn off the DCU to turn off the fixed DRU.

2. Cut the power and LAN cable connected to the fixed DRU.

Fixed DRU

Power cable

LAN cable

3. Removed three bolts (M12) to remove the fixed DRU from the mounting location.

4. Move the fixed DRU to a safe place suitable for data extraction.

See section 2.2 to make connections and extract the data.

8

2. DATA EXTRACTION FROM FIXED DRU

2.4

How to Remove the Capsule from the Fixed DRU

When you can not remove the entire fixed DRU due to damage, remove the capsule from the fixed

DRU for data extraction as follows:

Note: In an emergency situation, priority must be given to evacuation of personnel. Remove the fixed DRU only when there is enough time to do so.

1. Turn off the DCU to turn off the fixed DRU.

2. Release two snap pins.

3. Release two levers.

Capsule

Snap pin

(2 pcs,

both sides)

Lever

(2 pcs,

both sides)

4. Cut the cable (diameter: 9 mm) between the capsule and the terminal board.

Cut this cable.

5. Move the capsule to a safe place suitable for data extraction.

The Accident Investigator’s Kit (HVR04-AIK) is required for the data extraction from the capsule.

Contact L-3 Communications Holdings, Inc. to purchase the Accident Investigator’s Kit. For how to use the Accident Investigator’s Kit, see the document supplied with the kit.