3PD Time Switch Supplementary Information. Carmanah R820-E, R829-E, R920-E, R247-E, F series, R829-F, E Series, R920-F
Add to My manuals75 Pages
advertisement
![3PD Time Switch Supplementary Information. Carmanah R820-E, R829-E, R920-E, R247-E, F series, R829-F, E Series, R920-F | Manualzz 3PD Time Switch Supplementary Information. Carmanah R820-E, R829-E, R920-E, R247-E, F series, R829-F, E Series, R920-F | Manualzz](http://s3.manualzz.com/store/data/065078878_1-df0b8670eea0229e6bd2fbd94d1f36dc-360x466.png)
E / F SERIES USER MANUAL
5.0 INSTALLATION OF OPTIONAL ACCESSORIES
5.5 3PD Time Switch Supplementary Information
The F Series 3PD adapter mounting plate included with the various 3PD kit options has holes to accommodate a variety of third-party devices. These are summarized in the table and diagram below.
Application
3PD adapter mounting plate to solar engine
AI FCU 500
RTC AP21, CPR2102,
AP22
Encom WBCU
Eltec TC-18
Holes Used
1, 2, 3, 4
1, 2, 3, 4
9, 6, 8
IDC DC-FB (BT 5000) 11, 12, 13
5, 6, 7, 8
9, 6, 8
Installation and Wiring Notes
Also used to mount AI FCU 500.
Four provided screws go through holes in Al unit, then through holes in 3PD plate and into standoffs in F Series solar engine.
Standard wiring versions. TxDOT version requires removal of several contacts from provided harness connector using TE extraction tool
305183 and reinstallation into different positions:
Relay pins 4 and 10 are reversed.
DC+ moves from pin 15 to pin 11.
DC− moves from pin 13 to pin 12.
*
Standoffs go into switch, screwed onto plate from below.
Requires removal of several contacts from provided harness connector using TE extraction tool 305183 and reinstallation into different positions:
DC+ moves from pin 15 to pin 11.
DC− moves from pin 13 to pin 12.*
Used to mount relay in F Series DC Relay Kit option. DC Relay
Polara XAV
10, 6
5, 6, 7, 8 Controller comes preinstalled and prewired with F Series Polara XAV controller kit option.
*Consult manufacturer’s documentation to confirm.
3PD Adapter Mounting Plate
Carmanah Technologies Corp. | 250 Bay St, Victoria, BC V9A 3K5, Canada | 1.250.380.0052 | [email protected]
| carmanahtraffic.com
48
E / F SERIES USER MANUAL
5.0 INSTALLATION OF OPTIONAL ACCESSORIES
Pin Assignments of Connectors Provided with RTC/IDC and AI 3PD Kits
Pin Assignment in TE Circular Connector provided with RTC/IDC time switch kit:
Pin Assignment in TE Circular Connector provided with AI time switch and modem kit:
Carmanah Technologies Corp. | 250 Bay St, Victoria, BC V9A 3K5, Canada | 1.250.380.0052 | [email protected]
| carmanahtraffic.com
49
advertisement
Related manuals
advertisement
Table of contents
- 2 Table of Contents
- 4 1.0 Warnings and Precautions
- 4 Warranty Disclaimer
- 4 Standards
- 4 Safety and Usage Precautions
- 6 System Components
- 7 2.0 Introduction
- 7 About the E and F Series
- 8 Radio Communication
- 8 R920-E and R920-F: Pedestrian Crosswalk with RRFB Light Bars
- 10 R820-E and R820-F: Pedestrian Crosswalk with Circular Beacons
- 11 R829-E and R829-F: School Zone Flashing Beacon
- 12 R247-E and R247-F: 24-Hour Flashing Beacon
- 13 RRFB Light Bars: Overview
- 13 Circular Beacons: Overview
- 14 LED Enhanced Signs: Overview
- 14 Third-Party Devices: Overview
- 16 3.0 Solar Engine Installation
- 16 Tools and Materials Required
- 17 Solar Engine Mounting to Round Post
- 18 Solar Engine Mounting to Square Post with Universal Cast Mount
- 19 Solar Engine Mounting to Square Post with Steel Mount
- 20 Solar Engine Mounting to Side of Post
- 21 Reinforced Signal Head for Integrated Solar Engine / Signal Head
- 22 Integrated Solar Engine with Signal Head – Round Post
- 24 Integrated Solar Engine with Signal Head – Square Steel Post
- 26 Integrated Solar Engine with Signal Head – Square Wood Post
- 28 Integrated Solar Engine with Signal Head – Side of Post
- 30 4.0 Fixture, Push Button, & Battery Installation
- 30 RRFB Light Bar Installation
- 35 Circular Beacon Installation
- 36 LED Enhanced Sign Installation
- 37 Push Button Installation
- 39 Battery Installation
- 43 5.0 Installation of Optional Accessories
- 43 Calendar Upload / Override Switch Kit Installation
- 44 RTC Time Switch Installation (F Series only)
- 45 Information Display Company Time Switch Installation (F Series only)
- 46 Applied Information or FCU Modem Kit Installation (F Series only)
- 48 3PD Time Switch Supplementary Information
- 50 DC Relay Kit Installation (F Series only)
- 51 Polara XAV Controller Kit Installation (F Series only)
- 52 Campbell Guardian Audible Push Button Kit Installation (F Series only)
- 52 6.0 Energy Management System Programming and Testing
- 52 EMS On-Board User Interface Operation
- 65 R920-E/F Programming
- 65 R820-E/F Programming
- 65 R829-E/F Programming
- 65 R247-E/F Programming
- 66 7.0 Commissioning Checklist
- 67 8.0 Maintenance and Product Care
- 67 Fuse Replacement
- 68 Battery Replacement
- 68 EMS Replacement
- 70 EMS Recycling
- 71 9.0 Troubleshooting
- 72 BIST Error Codes
- 74 10.0 Customer Service and Warranty
- 74 Additional Products
- 75 Glossary