Range Hood. KitchenAid Commercial Style Wall-Mount Canopy Range Hood

Add to My manuals
36 Pages

advertisement

Range Hood. KitchenAid Commercial Style Wall-Mount Canopy Range Hood | Manualzz

6. Connect the same color wires to each other (black to black, white to white, etc.) using UL listed wire connectors.

NOTE: Connect the green (or green/yellow) ground wire from the wiring conduit to the green (or bare) ground wire from the home power supply using UL listed wire connectors (see the

“Make Electrical Power Supply Connections to Range Hood” section).

B

C

A

D

E

F

G

H

A. UL listed or CSA approved

¹⁄₂

" (1.3 cm) wiring conduit

B. UL listed wire connectors

C. Black wires

D. White wires

I

E. Red wires

F. Blue wires

G. Gray wires

H. Green (or green/yellow) wire

I. 6-wire connector assembly

7. Go to “Make Electrical Power Supply Connection to Range

Hood” section.

Make Electrical Power Supply Connection to

Range Hood

WARNING

A

B

C

D

F

E

A. White wires

B. Black wires

C. UL listed wire connectors

D. Green, bare or yellow/green wires

E. Home power supply

F. UL listed or CSA approved

¹⁄₂

" (1.3 cm) strain relief

3. Use UL listed wire connectors and connect black wires (B) together.

4. Use UL listed wire connectors and connect white wires (A) together.

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electrical shock.

1. Disconnect power.

2. Locate terminal box inside of the range hood.

Electrical Shock Hazard

Electrically ground blower.

Connect ground wire to green and yellow ground wire in terminal box.

Failure to do so can result in death or electrical shock.

NOTE: When using an in-line blower motor system, the green (or green/yellow) ground wire in the conduit from the In-line blower motor system is to be connected with the green (or bare) wire of the home power supply cable and with the green/yellow wire (D) in the terminal box.

5. Connect green (or bare) ground wire from home power supply to the green/yellow ground wire (D) in terminal box using UL listed wire connectors.

6. Install terminal box cover.

7. Check that all light bulbs are secure in their sockets.

8. Reconnect power.

B

A. Terminal box cover

B. Knockout in canopy back into terminal box

A

13

advertisement

Key Features

  • 30", 36", and 48" (76.2 cm, 91.4 cm and 121.9 cm) sizes to fit a variety of kitchen configurations
  • Convertible to ductless recirculating operation with optional charcoal filter kit
  • 4-speed electronic control with digital display for precise ventilation adjustment
  • Halogen lighting provides bright, energy-efficient illumination over the cooktop
  • Dishwasher-safe aluminum mesh filters capture grease and are easy to clean

Related manuals

Frequently Answers and Questions

What are the dimensions of the range hood?
The range hood is available in three sizes: 30" (76.2 cm), 36" (91.4 cm), and 48" (121.9 cm).
Can the range hood be used for recirculating operation?
Yes, the range hood can be converted to ductless recirculating operation with the optional charcoal filter kit.
How many fan speeds does the range hood have?
The range hood has 4 fan speeds for precise ventilation adjustment.
What type of lighting does the range hood have?
The range hood has halogen lighting that provides bright, energy-efficient illumination over the cooktop.
Are the filters dishwasher safe?
Yes, the aluminum mesh filters are dishwasher safe for easy cleaning.