Carry out configuration. Hydac PB_HLT 1100 SAE J1939

Add to My manuals
22 Pages

advertisement

Carry out configuration. Hydac PB_HLT 1100 SAE J1939 | Manualzz

HLT 1100 SAE J1939 g. Operation Data

Index sub index Data type r/w Settings

81 0 uint16 uint32 ro Measured value, position

Data type depending on Index 42 "data length"

82

85

0

0 uint16 uint32 uint8 ro Measured value, speed

Data type depending on Index 52 "data length" ro Status h. Additional settings for position and speed

Index sub index Data type r/w Settings

91 0 uint16 ro Integration time of the speed [ms]

92 0 Uint8 ro Measurement direction 0 = forward, 1 = backwards

(e.g. 0)

11

E i. Commands

see chapter 4.6

Commands

Index sub index Data type r/w Settings

101 0 uint32 wo Start editing mode ("edit")

102 0

103 0

104 0 uint32 uint32 uint32 wo Saving the settings ("save") wo Reset to factory default settings ("load") wo Restart ("boot")

4.2.2 Setting of the Baud rate

HLT supports Baud rates from 10 kBit up to 1 MBit, according to the following table:

Index Baud rate

5

6

7

8

0

1

2

3

4

1000 kBit

800 kBit

500 kBit

250 kBit

125 kBit

100 kBit

50 kBit

20 kBit

10 kBit

Edition: 2021-08-20 HYDAC ELECTRONIC GMBH Part no.: 670069

advertisement

Key Features

  • High-resolution measurement of position and speed
  • Fast sample rate for capturing even the smallest changes
  • Robust design for harsh environments
  • User-scalable linear process value
  • Cyclic transmission of measured values (1 millisecond to 1 minute)
  • Address claiming for clear identification on the bus
  • Configuration via industry-standard SAE J1939 protocol
  • Support for dynamic addressing for flexible network management

Related manuals

Frequently Answers and Questions

Can the device be used in harsh environments?
Yes, the Hydac PB_HLT 1100 SAE J1939 is designed with a robust construction to withstand harsh conditions.
How is the address of the device determined?
The device supports dynamic addressing according to the J1939-81 standard, allowing it to automatically claim an available address on the network.
Can the name of the device be changed?
Yes, the device supports changing the J1939 name via configuration or through the "name management" message (PGN 37632).