6.7 WebGUI Control

On a PC/Laptop that is connected to an active network system, open a web browser and type device’s IP address (default setting IP:

192.168.1.50 ) on the web address entry bar.

A security page will appear to ask for User and Password, please key in “admin” for both and click Submit to enter. The browser will display device’s Macro Setting, Extension Macro, Command, Network &

System Settings control pages for users to control.

6.7.1 Macro Settings

Click on 'Macro Settings' to execute or rename macro. There are

5 Macros inserted as default setting for testing the control system's functionality. Click on Macro 1~5 to demonstrate the functions:

• Macro 1: Close relay from 1~8 sequentially every 100ms

• Macro 2: Open relay from 1~8 sequentially every 100ms

• Macro 3: Toggles relay from 1~8 sequentially every 100ms

• Macro 4: Send IR signal from 1~8 sequentially every 100ms with LED illuminant on front panel.

• Macro 5: Send out command "Hello World" from COM port 1~2 sequentially every 100ms.

Macro 1~8 works align with Trigger IN 1~8 which means, when a trigger signal is activated the control system will execute the command under Macro Setting.

11

Click on the mark to edit the command settings. Up/down arrows are to move the command up or down and button is to delete the command.

Click on Insert button/Add to insert commands. Command can be set to control the Control System/SysCMD, other devices connected within the same Telnet system/Internet area, RS-232 COM ports, IR and

Relay devices connected through the Relay outputs of Control System with delay time. It is suggested the delay time is >100ms once the setting is confimed, double click on Save Change.

Command set to control the devices within the same telent system or internet area require to set its IP and Port number and it is strongly recommand to set the delay time >500ms in order to secure a successful command sending. Command set to control the Relay devices require to set the Port number. Click on Save Change to confirm the setting.

12

13

6.7.2 Extension Macro

Click on 'Extension Macro' to execute/edit more Macro action up to 8 more.

6.7.3 Command Settings

Click on 'Command Settings' to edit or delete commands up to 128 sets. Insert the command directly in the bottom colum of Command

Edit and name the command on the top colum then click on Save

Changes to store the command.

For IR command Learning, press IR Learn first then press the remote control in direct line-of-sight to the IR Reciever connected from the IRL port within 5 seconds. A comand string will show in the bottom colum.

Click on Save Changes to store the command.

Note: Some command may require to add a carriage return (eg:\r or

\x0D) in the end to allow the system to recognize it as an end of the command.

14

For IR command saving, insert the command on the bottom colum and click on CYP/RAW HEX which indicate the IR command type and click on Save changes to store the command. Under uncertainty of the IR command type click on RAW HEX to ensure a successful command saving.

Command under 128 characters including space can be build up to 128 commands, command over 128 characters and under 512 characters including space can be build up to 32 command in addition with 96 commands of 128 characters under. Click on Save

Change to save the command inserted.

6.7.4 Network Settings

Click on 'Network Settings' to set the device’s IP configuration. Once the changes are saved the system will reset the IP address on device automatically and user will need to re-enter the IP address to continue the WebGUI control.

15

System Settings

Click on 'System Settings' to reset the WebGUI login password and save or download the Macro settings. Reset to Default allows IP and login ID & password to be reset back to factory default.

Note: Please ensure that all commands and settings have been saved before performing Reset as this procedure may restore all settings back to factory default.

16