advertisement
![Adjustments. Clarke CCS305 | Manualzz Adjustments. Clarke CCS305 | Manualzz](http://s1.manualzz.com/store/data/068162798_1-046e6853e6cd8f738d38cd19386a09fb-360x466.png)
Fuse rating
The fuse in the plug or circuit, must be rated at 13 amps and the plug fuse must be
ASTA or BS approved to BS1362.
Cable extension
If a cable extension is needed, it is essential that it complies with the following specification.
Extension length Conductor section
Up to 15m 2.5mm
2
From 15 to 50m 4.0mm
2
ADJUSTMENTS
CAUTION
Before carrying out any adjustments, the machine must be disconnected from the electrical mains supply.
1.
Before use for the first time
IMPORTANT
:
Before starting your machine for the first time, it is important to ensure that the blade is central within the Blade Insert, and does not come into contact with the Insert when tilted to 45 0 .
Tilt the blade to 45 0 and rotate by hand to ensure there is no contact between it and the table insert. Should an adjustment be necessary, slacken the nuts securing the 8 countersunk screws that secure the two Side Brackets to the table
(shown in fig. 2), and move the complete lower guard box and side bracket assembly so that the blade is: a. parallel with the edge of the table b. central within the table insert so that there is no contact between the blade and insert.
Tighten the nuts securing the 8 countersunk screws when satisfied and recheck.
2.
Before each use
IMPORTANT
:
Each time you use the machine, you must ensure the components are correctly adjusted and checked for security BEFOREHAND.
A.
For normal ripping or cross cutting, the blade should be exactly square (at 90°), to the table. To check and adjust, you should proceed as follows:
16