Settings & Configurations. American Time SiteSync IQ Wired System

Add to My manuals
69 Pages

advertisement

Settings & Configurations. American Time SiteSync IQ Wired System | Manualzz

Settings and Configuration

SiteSync IQ Wired Installation Manual

Manually Setting Time and Date

Press P1 and enter your user lock then O (unless disabled) to access the Set Menu.

• a. Press: 1

• b. Enter the hours by pressing the two digit number

06 ) n Note: If 24 hour mode is active, skip to d.

• c. Toggle to AM or PM using B

Press B

• d. Enter the minutes by pressing the two digit number

30 )

• e. Enter the seconds by pressing the two digit number

45 )

Press when finished

• a. Press

• b. Enter the year by pressing the four digit number

2015 )

• c. Enter the month by pressing the two digit number

01 )

• d. Enter the date by pressing the two digit number (i.e. 01 )

Press to accept

1a

Set Menu Options

1=Time 2=Date

3=Time Zone & DST

4=12/24 9=Sync Now

1b

Set Menu Hour

Time: 12:00:00 AM

>=Mins

<=Secs OK=Accept

1c

Set Menu Hour

Time: 12:00:00 AM

>=Mins Back=AM-PM

<=Hours OK=Accept

1d

Set Menu Min

Time: 12:00:00 AM

>=Secs

<=Hours OK=Accept

1e

Set Menu Sec

Time: 12:00:00 AM

>=Hours

<=Mins OK=Accept

2a

Set Menu Options

1=Time 2=Date

3=Time Zone & DST

4=12/24 9=Sync Now

2b

Set Menu Year

2015 - 01 - 01

>=Month Back=Day

<=BkSpc OK=Accept

2c

Set Menu Month

2015 - 01 - 01

>=Day Back=Year

OK=Accept

2d

Set Menu Day

2015 - 01 - 01

>=Year Back=Month

OK=Accept

40

© American Time

SiteSync IQ Wired Installation Manual

Settings and Configuration

The Config Menu offers the ability to change several settings for the SiteSync IQ Master.

Press P7 and enter your service lock to access the Configuration Menu.

w

1

• a. User Lock. Press: 1 and enter a new 4 digit User Lock OR

Press 0000 to disable this feature.

User Lock

• Press n Note: User Lock is the user security level used for accessing time/date and event menus.

• b. Service Lock. Press: 2 and enter a new 4 digit Service

Lock or enter 0000 to disable this feature.

Service Lock:

• Press n Note: Service Lock is the service security level used for accessing

System Controller configuration menus.

3a

Config Menu

Choose User Lock:

xxxx

0000=Disable OK=Done

3b

Config Menu

Choose Service Lock:

xxxx

0000=Disable OK=Done x

3

This feature is used to determine the priority of time synchronization of the System Controller. This screen only displays the sync options that your System Controller supports.

• a. Press the number that corresponds to your time sync

priority

• b. Enter the minutes and seconds that the System Controller

should attempt to synchronize each hour to the time sync

option chosen.

y

4

This feature is used to set the clock code for wired clock circuits.

• a. Enter the clock code using the keypad

• b. Press O z

5

This feature allows for the deletion of all events or restoration of the

System Controller to factory defaults.

• a. Press 2 to delete all events or 0 to cancel.

• b. Press 1 to restore factory defaults or 0 to cancel.

4a

Config Menu

Time Sync Priority

1=(GPS)

Ok=Done

4b

Config Menu

Time Sync Priority

Set to Ethernet

At 04:15 OK=Done

5

Config Menu

Select Clock Code

01

OK=Done

6a

Config Menu

Clear All Events

1=Confirm

0=Cancel

6b

Config Menu

Restore Factory

Settings

1=Confirm 0=Cancel

© American Time

41

Settings and Configuration

6

This feature allows for the enabling and disabling of the Setup Wizard.

1 to Enable or 2 to Disable.

O when finished.

7

This feature allows for the customization of the banner text (up to 20 characters) displayed on the main screen.

< and > to scroll through the available list of characters. Press O to move to the next character.

O when finished.

8

This feature allows for the display to be presented in a small or large format. The contrast of the screen can also be set.

• a. Display size: Press 1 and choose 1 for large or 2

for small.

• b. Contrast Ratio: Press 2 and use the < and > keys

to change the contrast.

O when finished.

Auto DST Settings: From the Config Menu press 9

This feature allows the AUTO DST settings to be configured as necessary. This setting does not need to be changed unless the

Energy Policy Act of 2005 is amended.

• a. Start of DST: Use the < and > keys to choose the

starting week, day and month. Press O after each

selection. Use the keypad to enter the Bias and the <

> keys to set the "+" or "-".

O when finished.

• b. End of DST: Use the < and > keys to choose the

ending week, day and month. Press O after each

selection.

O when finished.

USB Flash Drive

Refer to Appendix F for instructions on updating the software on the

AllSync IQ Master.

SiteSync IQ Wired Installation Manual

8

Config Menu

Setup Wizard:

Disabled

1=Enable 2=Disable

9

Config Menu

Change Banner Txt 1

American Time

OK=Acpt

10a-large text mode

1 0 : 3 0

MON FEB 09 2008

:06

AM

10a-small text mode

TUE FEB 09 2008

10:30:06 AM USCT

American Time

Status=AUTO GPS=N

11a

Config Menu

START OF DST:

2nd SUN of MAR

BIAS + 1:00 OK=Acpt

11b

Config Menu

END OF DST:

Last SUN of OCT

OK=Accept

42

© American Time

SiteSync IQ Wired Installation Manual

Troubleshooting System Controller

TUE JUL 03 2018

10:38:06 AM USCT

American Time

Status=AUTO ETH=Y

If you have any of these problems, follow the appropriate steps:

1. System controller appears off (LCD dark) when power is connected:

• Disconnect power and remove top cover. Check fuse and replace if necessary.

2. Power has been reset, Press OK is displayed on the LCD screen:

• Verify that the power source is stable

-Press OK if there was a power outage

-Press OK if power is not supplied by a switchable plug

-Press OK if unit was unplugged

• Determine source of power loss

3. Unit Crashed. Press OK is displayed on the LCD screen:

-The system controller will automatically reset and resume normal operation if the unit crashes.

-Diagnostic information is saved to the unit for troubleshooting.

-If this occurs frequently, please update to the newest firmware, as the issue may have already been resolved.

4. Incorrect time is displayed by system controller after loss of power:

• Backup battery may be dead. Check for "Low Battery Voltage" message when time is displayed in small text (see Display Settings

section). If this message is displayed, replace battery with new CR2032 or equivalent 3v lithium battery. Install battery with +

side up, as shown below.

5. Power outage during Daylight Saving Time correction:

• If there is a power outage during the correction period for Daylight Saving Time, the secondary clocks might not correct. In this

case, the clocks can be reset manually (see Clock Troubleshooting) or they will automatically reset during their next reception

attempt after the power is restored.

6. Signal circuits not responding to programmed events:

• Refer to Wired Signal Circuit Troubleshooting Guide.

7. Unable to synchronize with Ethernet Time Source:

• Refer to the Ethernet Troubleshooting Guide.

8. Unable to synchronize with GPS Time Source:

• Refer to the GPS Troubleshooting Guide.

9. Lost or forgotten User Lock:

• Contact American Time Technical Support at the number listed below.

10. SiteSync IQ System Controller locks up or display goes blank:

• Use a pen, small screwdriver or paperclip to press the reset button (See diagram in Appendix G). OR

• Remove power from the unit by switching the Power Input switch off, wait 5 seconds, then turn the unit back on.

If the problem cannot be resolved after following these steps, call Technical Support at American Time at 800-328-8996.

Front of IQ Controller

Battery

Fuse

Fuse

Fuse

Back of IQ Controller

© American Time

43

Troubleshooting GPS

SiteSync IQ Wired Installation Manual

If you have trouble synchronizing to GPS, follow these troubleshooting steps:

1. If GPS receiving antenna has been connected to the SiteSync IQ System Controller for less than 25 minutes, the GPS time signal may be inaccurate. Allow more time. If still not synchronizing follow these steps:

Press: P5 , to check the GPS signal status.

GPS Time Menu

Choose:

1=Signal Status

2=Enable/Disable

Press: 1 , to check signal status.

GPS Time Menu - LAST

Signal Last Received

01-06-2014 12:28:15A

OK=Done 1=Retry

If no signal was received, continue to Step 2.

GPS Time Menu

No Signal Last Rec.

01-06-2014 12:28:15A

OK=Done 1=Retry

If signal was received, press O to view number of connected satellites. Press OBB to return to the Main screen.

GPS Time Menu-Now

Satellites: 3

01-06-2014 12:28:15A

USCST OK=Next n Note: If 0 satellites are connected, continue the troubleshooting steps.

2. Check the GPS cable connections between the System Controller and GPS antenna. Replace any damaged cables and verify the connectors are securely locked together. If you are using extension cables, try temporarily moving the system controller closer to the GPS antenna and connect without the extension cables (if possible).

3. If no signal has been received after checking the status and configuration, move the GPS antenna to a better location and follow the installation and configuration steps again.

4. Ensure the GPS update function is enabled:

P52 ;

Enter User Lock, then press O ;

Display should show:

Set Menu Mode

GPS Update Enabled

1=Disable GPS Update

OK=Done

If not, press 1 then O .

5. Inspect the GPS antenna for damage. Look for signs of lightning strikes or falling debris.

6. Look for obstructions to the antenna's view of the sky and remove them if possible (example: tree branches). Clear any snow or ice off the antenna and surrounding area.

7. If the GPS antenna is installed behind a Low-E glass window or skylight, try another location or replace the glass if

possible.

If the problem cannot be resolved after following these steps, please call Technical Support at American Time at 800-328-8996.

44

© American Time

SiteSync IQ Wired Installation Manual

Troubleshooting Ethernet

If you have trouble connecting the SiteSync IQ System Controller via Ethernet, follow these troubleshooting steps:

1. Check the Ethernet cable connection to the SiteSync IQ System Controller. Make sure the patch cable is securely connected to the Ethernet RJ-45 port and that it is not damaged. Have the cable tested or connect a computer or another Ethernet device to this cable to confirm proper connection.

2. Ensure that the Ethernet is enabled. From the main screen:

Press: P82 , enter User Lock, and press O . Press 2 to enter the Client menu.

If Ethernet is Disabled, press 1 to enable and press O .

Comm Menu

Enable/Disable

1=Remote Program

2=Client 3=Server

Comm Menu

Client

1=Enable 2=(Disable)

OK=Done

Verify the packet counts for RX and TX are greater than 0. Press 1O> from the Comm Menu.

If greater than 0 press OBB to return to the Main screen. If packet counts are 0, continue with troubleshooting

steps.

Comm Menu

Packets RX:0

Packets TX:0

OK=Done

3. Initiate Sync Now:

Press: P1 to Set Menu Mode.

Enter User Lock and press O .

Press: 9 to sync the System Controller with Ethernet. Press > until Ethernet option is chosen.

8 to sync with Ethernet.

Set Menu Mode

Time Sync Option is

Available: Ethernet

8=Sync now OK=Set

4. Confirm all Network settings (see "Ethernet Installation" section of this manual). Make sure the SiteSync IQ System

Controller is configured properly.

5. Change the Time Server IP address to a different timeserver among those listed in Appendix A. Perhaps the timeserver that the system controller is attempting to communicate with is down or not responding quickly enough due to network traffic, etc.

6. Press P85 , to See the current IP address. Confirm the IP address is valid and no other device or computer on the network is using the same IP address.

7. Ensure that the Network has port 123 open for SNTP or port 13 open for Daytime Protocol.

8. Ping the IP address of the unit from another computer to see if it is responding. Check with your Network

Administrator if you do not know how to do this.

9. Test the time server by attempting to get a time stamp from another computer. Check with your Network

Administrator if you do not know how to do this.

If the problem cannot be resolved after following these steps, please call Technical Support at American Time at 800-328-8996.

© American Time

45

Troubleshooting Remote Connect

SiteSync IQ Wired Installation Manual

If you have trouble connecting the SiteSync IQ System Controller to the Remote Connect software, follow these troubleshooting steps:

1. Check the Ethernet cable connection to the SiteSync IQ System Controller. Make sure the patch cable is securely connected to the Ethernet RJ-45 port and that it is not damaged. Have the cable tested or connect a computer or another Ethernet device to this cable to confirm proper connection.

2. Ensure that the Remote Programming is enabled. From the main screen:

Press: P82 , enter User Lock, and press O . Press 1 to enter the Remote Prog menu.

Comm Menu

Enable/Disable

1=Remote Program

2=Client 3=Server

If Remote Programming is Disabled, press 1 to enable and press O .

Comm Menu

Remote Programming

1=Enable

2=Disable OK=Done

3. Confirm all Network settings (see "Ethernet Installation" section of this manual). Make sure the SiteSync IQ System

Controller is configured properly.

4. Press P85 , to See the current IP address. Confirm the IP address is valid and no other device or computer on the network is using the same IP address.. The Network Administrator should be able to resolve any conflicts.

5. Ensure the Network has Port 80 open.

6. Ping the IP address of the unit from another computer to see if it is responding. Check with your Network Administrator if you do not know how to do this.

7. If the Sitesync IQ system controller is configured in DHCP mode and you are not able to connect to the Remote Connect interface, ensure that the device is on a network that will serve DHCP addresses. If no DHCP server is present or fails to receive an address, the SiteSync IQ system controller will default to 192.168.10.10. Try connecting to the SiteSync IQ system controller by typing in its IP address in the address field of the browser in this format: http://xxx.xxx.xxx.xxx./ or Host

Name: http://ssiqxxxxxx/ and click Enter.

n Note: The connecting computers IP address must be on the same Subnet.

Example 1 - IP address

Example 2 - Host Name

If the problem cannot be resolved after following these steps, please call Technical Support at American Time at 800-328-8996.

46

© American Time

SiteSync IQ Wired Installation Manual

Troubleshooting Contact Closure Sync

If you have trouble connecting the SiteSync IQ System Controller via Contact Closure, follow these troubleshooting steps:

1. Verify that contact closure sync is enabled: a. System Controllers with {GPS + Ethernet} or do not have contact closure input capability. See the table on Page 5 and

refer to your model number.

b. Confirm contact closure is enabled in the Comm Menu by pressing P9 User Lock O . See Page 18 for more

information.

2. Check the Contact Closure connection to the IQ System Controller. Make sure the two wires are securely connected.

3. Ensure that the sync time is correct. See instruction on Page 18 for setting the sync time on the SiteSync IQ System

Controller. Refer to the instructions provided by the manufacturer of any connected device to set its sync time.

4. Test contact closure wiring by removing the two wires from the output device and shorting them together. If this does not result in the receiving device going to the specified sync time, try removing the two wires from the receiving device and using a jumper wire to short the terminals.

If the problem cannot be resolved after following these steps, please call Technical Support at American Time at 800-328-8996.

© American Time

47

Troubleshooting Wired Clock Circuit

SiteSync IQ Wired Installation Manual

If you have trouble operating wired clock circuits, follow these troubleshooting steps:

1. Ensure you have the clock code configured in your system controller:

P7 to enter the Config Menu b. Enter your Service Lock if necessary.

4 to enter the Clock Code select screen and verify that it is correct.

Config Menu

Select Clock Code

01

OK=Done

2. If the system controller time was recently changed, allow up to 24 hours for secondary clocks to re-synchronize to the system controller.

3. Ensure there is sufficient voltage across each secondary clock.

4. If fewer that 25 AllSync secondary clocks are connected to the system controller, the secondary clocks might not recognize the correction from the system controller. Connect all intended clocks and allow time for normal system controller correction. If secondary clocks still have not corrected, you may need additional hardware. Contact American

Time Technical support for information on adding a Resistor Pack (Part #H001941) to your system.

If the problem cannot be resolved after following these steps, please call Technical Support at American Time at 800-328-8996.

48

©American Time

SiteSync IQ Wired Installation Manual

Troubleshooting Wired Signal Circuit

If you have trouble operating wired signal circuits, follow these troubleshooting steps:

1. Signal circuits not responding to programmed events: a. Make certain that the system controller status is set to AUTO:

8 , enter User Lock, if applicable, and press O .

b. Confirm that signal circuits are enabled. From the View Circuits screen:

3 to enter the Enable Circuits screen to view or change the control status of individual circuits.

Circuit Menu

Enable Cir: OK=Done

1=On 2=On 3=On

4=On 5=On 6=On c. Confirm that signal circuits and events programmed to control them are assigned to the same schedule.

d. Check for correct voltage at signal relay contacts. The COM (common) terminals should measure full voltage all the time.

The NO (normally open) terminals should have power only when the circuit is activated.

2. Signal circuit(s) On when they should be Off:

a. Press M , enter User Lock, if applicable, and press O . Then choose circuit(s) to activate/deactivate.

b. If the circuit does not toggle On or Off, check for stray voltage on the signal relay normally open contacts. n Note: You can try disabling the surge protection circuitry by switching it off (see diagram). These switches are located inside the wiring compartment. Remove power to the System Controller and signal circuit lines before removing cover to

access wiring.

c. Verify the LED for the circuit is Off (see diagram).

3. Signal circuits not responding at all: a. Carefully open the top cover of the SiteSync IQ System Controller by removing the screws on each side of the unit.

b. Press the M key, enter User Lock, if applicable, then press O .

c. Choose the circuit(s) you wish to test and press the M key to trigger the applicable relay(s).

d. Observe the LED(s) next to the circuit relays being tested. If they light up when the circuit is being triggered, verify the

operation of the relay by measuring the voltage on the relay terminals. The NO terminal should have power. If they don't

light up, verify the circuits are enabled (see Step 1b above).

n IMPORTANT NOTE: Relay 6 will be inoperable for running events when the SiteSync IQ System Controller is being used to provide contact closure synchronization (Tx mode).

If the problem cannot be resolved after following these steps, please call Technical Support at American Time at 800-328-8996.

Relays

Circuit LEDs

(orange)

1 2 3 4 5 6

Surge Protection

Switches

NO COM

CLOCK 1

NC NO COM

CLOCK 2

NC NO

BELL 1

COM NO

BELL 2

COM NO

BELL 3

COM NO

BELL 4

COM NO

BELL 5

COM NO

BELL 6

COM

Signal Circuit Terminals

©American Time

49

advertisement

Related manuals