1. Keys and indicator lights
Touchscreen terminals
Touchscreen terminals do not have a keypad.
Regarding to the Touchscreen with touch keys, the keys run the same way as the touch zone. Those keys give a "mechanical feeling" that isn't felt on the tactile zone (manipulation with gloves).
For each key of terminals with keyboard an equivalent will be given for touchscreen terminals.
Pressing this touch zone called the service touch icon provides access to a context “keyboard”. Depending on the presence of some functions, the “keyboard” may or may not display the corresponding “buttons”.
Keys and indicator lights
Functions of the keys and indicator lights
ENTER: To confirm a choice or an entry, acknowledge an alarm.
Press the ENTER touch icon on the touchscreen terminal to access this function.
Acknowledge an alarm on touchscreen terminals.
D - 6
MOD: Switch to entry mode on all the applicable fields or graphic objects
(not existing on touchsreen terminals).
ESC: To cancel an entry, or suspend or stop an action in progress.
To display the preceding pages successively. To exit from alarm display.
Press the service and ESC touch icons to access this function on touchscreen terminals.
SHIFT: To access a key's second function.
No equivalent touch icon is available on touchscreen terminals.
MENU: To access a menu that contains the run-time functions that cannot be accessed directly by means of a key:
- application page selection,
- the "secondary" run-time functions.
Press the service and MENU touch icon to access this function.
Graphic Magelis
1. Keys and indicator lights
Keys and indicator lights
Functions of the keys and indicator lights
HOME: To return to the page displayed when the terminal is switched on.
Press the service and HOME touch icons to access this function on touchscreen terminals.
SYST : To access the system pages that contains the maintenance configuration functions.
Status of the indicator lights associated with the SYST key:
- Off: the terminal is in running mode.
- On: the terminal is in confidential mode.
- Flashing: PC <-> XBT transfer in progress or no application in the terminal.
Press the service and SYST touch icons to access this function on touchscreen terminals.
For touchscreen terminal
ALARM
ALARM : To display the alarms
Status of the indicator light associated with the key:
- Off: the current list of alarms is empty.
- On: the list contains alarms that have already been displayed.
- Flashing: the list of alarms contains new alarms.
Press the service and ALARM touch icons to access this function on touchscreen terminals.
PRINT: Print command.
Status of the indicator lights associated with each key:
- Off: no printing possible
- On: printing possible (list of alarms, etc.)
- Flashing: printing error.
Press the service and PRINT touch icons to access this function on touchscreen terminals.
D
Graphic Magelis D - 7
1. Keys and indicator lights
Keys and indicator lights
Functions of the keys and indicator lights
The left and right arrow keys are used to:
- To select an object in a page.
- To move during an entry in an alphanumeric field.
- To change the cursor position on a switch or a potentiometer.
Status of the indicator lights associated with each key:
- Off: key inactive.
- On: indicates the possibility of moving around in a page from field to field.
- Flashing: indicates the possibility of moving around in the selected variable alphanumeric field or of changing a cursor position.
The up/down arrow keys are used to:
- To move around in a page.
- To select a value in a list of values.
- To change the cursor position of a swtich or a potentiometer.
Status of the indicator lights associated with each key:
- Off: key inactive.
- On: indicates the possibility of moving around in a page from field to field.
- Flashing: indicates the possibility of moving around in the selected alphanumeric variable field, changing the cursor position or selecting a value in a list.
For touchscreen terminals, press the object icon to select an object in a page. If data entry or cursor moving is valid for the object, touch icons corresponding to the object context are displayed (for example: a numeric pad for entering a numerical value, increment/decrement arrows for a potentiometer, etc.).
Communication indicator light
- On: no cable or incorrect wiring,
- Off: cable correct, no exchange with the PLC,
- Flashing: exchanges with the PLC.
Keypad indicator light
- Off: no keys pressed, on the keypad or on the touchscreen pad.
- On, green: when pressing any key or a touch zone.
- On, red: the terminal is in standby mode. Press any key or the touchscreen pad to exit this mode. Press any key or the tactile pad to exit this mode.
D - 8 Graphic Magelis
1. Keys and indicator lights
Keys and indicator lights
Functions of the keys and indicator lights
Entering data in the various fields
The up/down arrow keys combined with the SHIFT key are used to increment or decrement the value in a variable field if the "access" parameter of the object entered has been configured to immediate write
(or immediate read/write). The value is entered in the control system each time the SHIFT + arrow up/down key is pressed.
Status of the indicator lights associated with each key:
- Off: key inactive.
- Flashing: indicates the possibility of modifying the value of each digit.
To delete the character to the left of the cursor
.
Alphanumeric entry keys
To reverse the sign of the variable field being entered
Decimal point
Combined with the alphanumeric keys, these keys give access to the capital character situated on the left, in the middle, on the right of the group of letters.
Combined with SHIFT and the alphanumeric keys, these keys give access to the small letter situated on the left, in the middle, on the right of the group of letters.
The indicator lights indicate if letter entry is possible.