ET HERNET / IP
USER MANUAL
2. Data Transmission
The data transmission in the EtherNet/IP network is realized by implicit or explicit messaging. Explicit messages are split in unconnected and connection based versions. Unconnected messages will be use i.e. by EtherNet/IP scanners.
Version 05/09 Page 6 UMUS-OCD-EE
Exclusive-Owner, Input Only Listen Only
It is possible to open 256 connections to the encoder. One could be an Exclusive Owner connection, 255 additional connections can be realized mixed in Input Only or Listen Only.
With an Exclusiv Owner connection can be transmit the parameters (cycle time, configuration and Assembly Instances) to the encoder.
ET HERNET / IP
USER MANUAL
Input Only connections can only work if all of the parameters are according to the encoder parameters.
Listen Only need an connection of Excusiv
Owner or Input Only.
Assembly
Connection Manager
Exclusiv-Owner
Config
Config
0x6A hex
Output Instance Input Instance
Connection Point 1 Connection Point 2
(106) 0x69 hex
(105)
0x01 Position value
0x03 Position value + velocity
Input Only
Listen Only
0x6A
-
0x68 hex hex
(106) 0x64
(104)
0x65
0x67 hex hex hex
(100)
(101)
(103)
0x01 Position value
0x03 Position value + velocity
0x01 Position value
0x03 Position value + velocity
0x66 hex
(102) Demo-Scanner
Version 05/09 Page 7 UMUS-OCD-EE
Communication check
ET HERNET / IP
USER MANUAL
Version 05/09 Page 8 UMUS-OCD-EE
advertisement
Related manuals
advertisement
Table of contents
- 5 1. Introduction
- 6 1.1 Control and Information Protocol (CIP)
- 7 1.2 Object model
- 7 2. Data Transmission
- 10 2.1 Implicit Messaging I/O Connection
- 10 2.1.1 I/O Assembly Instances
- 10 2.1.1.1 Data Attribute Format
- 10 2.1.2 Data Mapping
- 11 2.1.3 Data Mapping (Parameter)
- 11 2.1.3.1 Data Offset
- 12 2.1.4 Connection Path
- 12 2.2 Explicit Messaging
- 13 Position Sensor Objects
- 14 2.3 TCP/IP Interface Object
- 16 2.3.6 Host Name
- 17 2.4 Ethernet Link Object
- 18 2.4.0 Instance Attributes
- 19 2.4.1 Interface Flags
- 19 2.4.2 Common Services
- 20 2.4.3 Link Object Instances
- 20 2.5 Setting parameters with scanners
- 21 2.5.1 Read out position value
- 22 2.5.2 Set preset value
- 22 2.5.3 Get preset value
- 23 3 Diagnostic
- 25 4 Programmable Parameters
- 25 Object Class 23hex
- 25 4.1.1 Direction counting
- 25 4.1.2 Scaling function control
- 25 4.1.3 Resolution per revolution
- 26 4.1.4 Total resolution
- 26 4.1.5 Preset value
- 27 4.1.6 Velocity Format
- 27 4.1.7 Velocity Filter
- 27 4.1.8 Device Type
- 28 4.1.9 Endless Shaft
- 29 5. Installation
- 29 5.1 Electrical connection
- 29 5.2 Ethernet cables
- 30 6 Power On
- 30 7 Installation
- 30 7.1 Rockwell configuration tools
- 30 7.1.1 Setting IP-Address (BOOTP/DHCP)
- 33 7.1.2 Configuration RSLinx Classic
- 35 7.1.3 RSNetWorx
- 39 7.1.4 Configuration RSLogix
- 46 7.2 Schneider configuration tools
- 46 7.2.1 Setting configuration
- 50 7.2.2 Online configuration
- 52 7.3 BOOTP/DHCP and IP configuration tool
- 53 8 FAQ
- 53 9 Glossary