Stopping Engine. Echo SRM-3020T
تبلیغات
تبلیغات
SRM-3020T
2.
Purge Bulb
Pump purge bulb (B) until fuel is visible in the “Clear” fuel return line. Pump bulb an additional four or five times.
B
OPERATION
3.
Recoil Starter
Lay the unit on a flat area and keep movable attachment parts clear of all obstacles. Firmly grip throttle handle and throttle trigger lockout with left hand.
Rapidly pull recoil starter handle/rope (D) until engine fires.
Note: If engine does not start after five pulls, use Cold Start
Procedure.
D
Stopping Engine
1.
Throttle
Release throttle trigger and allow engine to return to idle before shutting off engine.
2.
Stop Switch
Move stop switch button (A) backward to STOP position.
A
If engine does not stop when stop switch is moved to STOP position, close choke - COLD START position - to stall engine.
Have your ECHO dealer repair stop switch before using unit again.
X7502350103