E6580772③
3. Functional description
In this section, functions added by the installation of this F10M option unit, on top of the standard inverter functions, are described.
3.1 F10M communication function
Through the communication network, drive and stop control and concentrated monitoring control of operation status can be carried out by the programmable controller and industrial computer.
3.1.1 Connection of transmission cable z SL1, SL2, SG
Transmission path is constructed by the shielded twisted pair cables as shown in the figure below.
Be sure to connect SL1, SL2 and SG mutually to another station. Note that wrong connection will not bring the correct transmission.
z SHD
Connect a shield of twisted pair cable to the transmission terminal SHD of each station and set up a class 3 or equivalent grounding work in an arbitrary station.
z Terminal
Set terminal resistors at both sides of the system for the sake of impedance matching. Connect terminal resistor (120Ω-1/2W) between the terminal block SL1 and SL2.
(As for the master station (MS), terminal resistor can be combined by connecting L1 and TERM.)
Shielded twisted pair cable
MS
TERM
L1
L2
SG
FG
TLF0 0 1 Z
SL1
SL2
SG
SHD
TLF0 0 1 Z
SL1
SL2
SG
SHD
TLF0 0 1 Z
SL1
SL2
SG
SHD
Terminal resistor
120 Ω-1/2W
Grounding / Earthing
(Grounding / earthing resistance 100 Ω max.)
Connection of communication cable of TOSLINE F10M
Signal name
SL1
SL2
SG
Name
Transmitting and receiving data
Transmitting and receiving data
Signal ground
Detail
Positive line
Negative line
Ground of signal line
•
Do not connect a grounding line of the shield and a power line earth of the inverter or so.
•
Separate a transmission cable from the main circuit connection wire by more than 200mm.
10
advertisement
Related manuals
advertisement
Table of contents
- 6 1. NAME AND FUNCTION OF EACH SECTION
- 6 1.1 Appearance
- 7 1.2 Name of each section (terminal)
- 8 2. CONNECTION TO THE INVERTER
- 8 2.1 Connection to the inverter
- 10 2.2 Wiring
- 11 3. FUNCTIONAL DESCRIPTION
- 11 3.1 F10M communication function
- 11 3.1.1 Connection of transmission cable
- 12 3.1.2 Setting of communication parameters
- 13 3.1.3 Communication parameters
- 16 3.2 Vector control with sensor
- 16 3.2.1 PG input setting
- 17 3.2.2 Connection of PG
- 19 3.2.3 Selection of encoder type
- 20 3.2.4 Vector control setting parameter
- 22 3.2.5 Monitoring method for feedback amount
- 22 3.2.6 Accuracy of speed control
- 23 4. EXTERNAL DIAGRAM
- 24 5. SPECIFICATION