Operating Instructions Field Evaluation Unit CES-FD-AP-.-01-…
System status table for version Unicode
LED indicator output
Operating mode State
Teach-in standby
Setup
Fault display
closed on
Normal operation
closed on open off open off closed
X
X off off off closed off
X
X off off
3 x
4 x
5 x flashes quickly
2 Hz
1 x
3 x
1 Hz
Normal operation, door closed
Normal operation, door closed, actuator in the boundary area
¨
Re-adjust door
Normal operation, door open, no actuator taught
Door open, unit is ready for teach-in for another actuator (only short time after power-up)
Teach-in operation
Positive acknowledgment after completion of teach-in operation
Fault on the power supply (e.g. Switch-off pulse duration of clocked power supply too long)
Defective actuator (e.g. fault in code or code not readable)
Output error (e.g. short circuits, loss of switching ability)
Internal fault (e.g. component faulty, data error)
Key to symbols
Important:
10 Hz (8 s)
X
3 x
LED not illuminated
LED illuminated
LED flashes for 8 seconds at 10 Hz
LED flashes three times, and this is then repeated
Any state
After the cause has been remedied, faults can generally be reset by opening and closing the door. If the fault is still displayed afterward, briefly interrupt the power supply. Please contact the manufacturer if the fault could not be reset after restarting.
If you do not find the displayed device status in the System status table, this indicates an internal device fault. In this case, you should contact the manufacturer.