B. RS-485 Termination

The 1 st

DIP of SW2 is used for 100Ω termination.

Set on 1 st

DIP of SW2 only by the last connected camera from the loop (CAM n).

Even in case of only one camera, set ON 1 st

-DIP of SW2.

C. Protocol

The 3 rd

, 4

TH

of DIP SW2 above are used for Protocol Setting.

Factory Default: Pelco-D or Pelco-P (Auto detection)

DIP SW2 - 3 rd

4 th

OFF / OFF

ON / ON

Pelco-D or Pelco-P

Maxpro protocol

D. Baud Rate Setting

The 7 th

, 8 th

SW of DIP SW2 is used for Baud Rate setting.

With DIP SW2 Baud Rate can be changed to 4800bps, 9600bps.

Factory Default: 2400bps.

DIP SW2-7 th

OFF ON 2400bps

* The 2 nd

, 5 th

, 6 th

of DIP SW2 are not used.